Skip to main content
Jornal Brasileiro de Nefrologia logoLink to Jornal Brasileiro de Nefrologia
. 2026 May 11;48(3):e20250199. doi: 10.1590/2175-8239-JBN-2025-0199en
View full-text in Portuguese

Translation, cross-cultural adaptation and psychometric validation of the Brazilian version of the dialysis patient-perceived exercise benefits and barriers scale

Graziella Alves da Silva 1, Cid André Fidelis de Paula Gomes 1, Thamiê Cristina Stella 1, Barbara G Miura 1, Jing Zheng 2, Renato D Foresto 3, Renata Kelly de Palma 4, Almir V Dibai-Filho 5, Luciana Maria Malosá Sampaio 1
PMCID: PMC13178697  PMID: 42114104

Abstract

Background:

Chronic kidney disease (CKD) in dialysis patients compromises musculoskeletal health and reduces physical activity levels. The Dialysis Patient-Perceived Exercise Benefits and Barriers Scale (DPEBBS) was specifically developed to assess dialysis patients’ perceptions of exercise. This study aimed to translate, cross-culturally adapt, and evaluate the psychometric properties of the Brazilian version of the DPEBBS (EPAD).

Methods:

A cross-sectional study was conducted following the COSMIN guidelines. Psychometric properties assessed included reliability, internal consistency, and construct validity. Participants were recruited from the hemodialysis department of Unifesp. A total of 112 adults on dialysis completed the DPEBBS, the Short Form Health Survey-36 (SF-36), and underwent anthropometric evaluation. The interval between test–retest was one week. Descriptive and inferential analyses were performed to test validity and reliability.

Results:

The scale demonstrated high test–retest stability, with consistent mean scores across assessments. Internal consistency was strong, and reliability was supported by a low minimal detectable change and a high intraclass correlation coefficient. Convergent validity with the SF-36 Physical Functioning domain was weak but statistically significant (r = –0.326; p = 0.001), and the correlation with the General Health domain was weak and not statistically significant (r = –0.185; p = 0.052). Consistency analysis showed α = 0.885, ICC = 0.794, SEM = 4.96%, and demonstrated the absence of floor and ceiling effects.

Conclusion:

The EPAD showed robust validity and reliability for dialysis patients. Despite adequate reliability and validity, this study has limitations, including a single-center sample. The EPAD may support individualized exercise counseling and rehabilitation planning in hemodialysis units.

Keywords: Renal Insufficiency, Chronic; Renal Dialysis; Exercise; Surveys and Questionnaires

Introduction

Chronic kidney disease (CKD) is defined as abnormalities in kidney structure or function lasting more than three months and is classified into five stages according to the level of glomerular filtration rate (GFR) reduction. In advanced stages, when GFR falls below 15 mL/min/1.73 m2, patients develop endstage renal disease and require renal replacement therapy (RRT), which includes kidney transplantation or dialysis 1,2 . Dialysis may be performed as either peritoneal dialysis or hemodialysis, with the choice of modality depending on the patient’s clinical condition and lifestyle rather than the superiority of one method over another 3 .

Currently, CKD is a significant public health issue in Brazil, with the prevalence of patients enrolled in dialysis programs increasing exponentially in recent years. The number of patients on dialysis more than doubled between 1994 and 2004, from 24,000 patients in 1994 to 59,153 patients in 2004, with the incidence of new patients growing by about 8% per year 4 . From 2017 to 2018, the number of patients with kidney disease with access to treatment increased by 98% in Brazil compared with the period from 2007 to 2009 5 . A comparison of Brazilian data with global statistics reinforces the relevance of policies aimed at the prevention and treatment of CKD, especially in the context of low- and middle-income countries, where the disease burden is disproportionately higher. CKD is also strongly associated with cardiovascular diseases, contributing to 1.4 million heart-related deaths and 25.3 million disability-adjusted life years (DALYs) due to impaired kidney function. This information highlights the need for greater global attention to CKD, particularly in regions such as Latin America, where the disease burden is higher than expected for the level of socioeconomic development 6 .

Chronic diseases are the leading cause of premature death in adults worldwide, particularly in low- and middle-income countries, where 80% of these deaths occur. It is estimated that in 2005, chronic diseases accounted for 35 million (60%) of a total of 58 million deaths from all causes 7,8 . Among these conditions, CKD is prominent, with systemic arterial hypertension, diabetes, and dyslipidemia among its main contributing factors 5 , emphasizing the importance of multidisciplinary follow-up for these patients. Among the various complications associated with CKD are physical disability, weakness, reduced quality of life, and an increased risk of death from cardiovascular events 9,10 .

Public spending associated with the chronic treatment of CKD in dialysis patients is also a concern, as there is significant utilization of healthcare resources, including consultations, hospitalizations, and renal replacement therapy (RRT) 1 .

It is well established that physical activity provides substantial benefits for patients with CKD, particularly those undergoing dialysis 11 . Regular exercise is associated with improvements in musculoskeletal health, physical function, fatigue, quality of life, and cardiorespiratory fitness and may also contribute to reduced cardiovascular morbidity and mortality 12 . Despite this robust body of evidence, most dialysis patients remain insufficiently active, and adherence to exercise and rehabilitation programs is consistently low 13 .

Multiple factors contribute to the low levels of physical activity observed in this population. Among the most frequently reported determinants are perceived barriers, such as fatigue, fear of injury, comorbidities, and physical limitations, as well as a lack of awareness or understanding of the specific benefits of exercise. In addition, insufficient counseling and encouragement from healthcare professionals may further limit engagement in physical activity 14,15 . Sociodemographic factors, including age and sex, as well as the type and context of physical activity, also play a significant role in influencing participation among adults in general and among dialysis patients in particular 16 .

Although these barriers and determinants are well recognized, their systematic assessment in clinical and research settings remains challenging. While several generic physical activity questionnaires are available, few instruments are specifically designed for and psychometrically validated in the dialysis population. This represents an important gap, as dialysis patients have unique clinical characteristics, treatment-related constraints, and perceptions that may not be adequately captured by generic tools. Therefore, the availability of valid and reliable instruments tailored to dialysis patients is essential for better understanding physical activity behavior, for identifying modifiable barriers, and supporting individualized exercise counseling and rehabilitation planning in this population 9,10,14 .

Different scales and questionnaires aim to measure physical activity levels in adults 17 , as well as establish effective proposals for activities with higher adherence rates, and this is no different for chronic kidney disease patients 18 . Currently, several scales and questionnaires evaluate physical activity levels and potential barriers faced by the adult population when engaging in physical activity; however, it is important that this evaluation be conducted specifically in patients with chronic kidney disease, considering their particularities. In this context, the tools available for such evaluation are considerably scarcer 19,20 .

Given the persistent low adherence to exercise among dialysis patients and the central role of perceived benefits and barriers in shaping physical activity behavior, the use of instruments that specifically capture these constructs is essential 21 . The Dialysis Patients’ Exercise Benefits and Barriers Scale (DPEBBS) 22 was developed in China to assess dialysis patients’ perceptions of the benefits of exercise and the barriers that limit its practice, addressing dimensions that are directly relevant to this population and not fully captured by generic physical activity questionnaires. Therefore, the DPEBBS represents an appropriate and clinically meaningful tool for evaluating key determinants of exercise behavior in dialysis patients, supporting both research and individualized exercise counseling and rehabilitation planning.

Scales developed for other populations or in other languages need to be validated before they can be used safely and reproducibly in different languages and cultures. As the DPEBBS was originally developed in China, its translation, cross-cultural adaptation, and validation are required to ensure its conceptual equivalence, reliability, and validity for use in other linguistic and cultural contexts. Validation studies of available tools for various assessments have been effective in supporting the evaluation and treatment of patients across different health conditions 23 . This study aimed to translate and cross-culturally adapt the DPEBBS into Brazilian Portuguese and evaluate its psychometric properties in adult patients on hemodialysis.

Methods

Study Design and Participants

A cross-sectional study was conducted in which the DPEBBS, the SF-36, and anthropometric assessments were applied, following the COSMIN guidelines to ensure the reliable measurement of the scale’s properties. These guidelines provide different classifications based on sample size, with a sample of ≥100 participants being classified as “very good.” 24 This classification aims to assess internal consistency, agreement, reliability, and convergent validity of a questionnaire undergoing validation and cross-cultural adaptation. Factor analysis was not performed in the present study because the factor structure of the DPEBBS has already been established in the original instrument through exploratory and confirmatory factor analyses. Given that our primary aim was cross-cultural adaptation and the assessment of reliability and validity, the previously validated structure was retained; therefore, a minimum sample size of 100 participants was considered adequate.

To be included in this study, participants needed to have a diagnosis of dialysis-dependent CKD, be ≥18 years old, and be clinically stable (i.e., absence of cardiovascular events, medication changes, or dialysis regimen modifications in the previous four weeks, and stable general health). Individuals who did not adhere to dialysis, as well as those with other diseases or physical conditions that prevented them from undergoing the assessments due to musculoskeletal or cognitive limitations, were excluded from the study. Patients were recruited from the Hemodialysis Department of the Hospital do Rim – Osvaldo Ramos Foundation – Federal University of São Paulo (Unifesp). After receiving an explanation of the study and its procedures and signing the Informed Consent Form (ICF), participants underwent anthropometric evaluation and completed the SF-36 and the DPEBBS.

Translation and Cross-Cultural Adaptation

The translation and cross-cultural adaptation of the DPEBBS followed established international recommendations for the adaptation of health-related instruments. The original scale, developed in Chinese, was initially translated into Portuguese by a Brazilian physician fluent in Chinese, with clinical experience in dialysis care and familiarity with exercise-related concepts.

Subsequently, the Portuguese version was back-translated into Chinese by a native Chinese physician fluent in Portuguese, who was blinded to the original version of the instrument and had no access to its content. The back-translated version was compared with the original Chinese scale to assess semantic, idiomatic, and conceptual equivalence. A third translator, fluent in both Chinese and Portuguese and not affiliated with the healthcare field, evaluated any terms that might hinder patient understanding.

A pretest was conducted with 10 dialysis patients to evaluate clarity, comprehension, and cultural adequacy of the translated instrument. No difficulties in understanding the items or response options were identified, and no changes were required following the pretest. The pilot administration of the scale was carried out by physiotherapists, who also reported no difficulties in administering the instrument.

Finally, the back-translated version was sent to the School of Nursing at Sun Yat-sen University, the copyright holder of the DPEBBS, who suggested minor wording adjustments. These recommendations were incorporated into the final Portuguese version of the scale, which was subsequently applied to the full study sample. The scale was applied twice to the participants to assess test–retest reliability, with a one-week interval between assessments. This interval was short enough to avoid clinical changes but long enough to minimize recall of previous responses. Only clinically stable patients were reassessed for test–retest reliability, according to the predefined stability criteria.

Statistical Analysis

Data analysis was performed using SPSS software (version 26.0; SPSS Inc.; Chicago, Illinois, USA). The Shapiro–Wilk test was used to determine data normality. In the descriptive analysis, parametric variables were expressed as mean and standard deviation (SD). For non-parametric variables, the median and interquartile range (IQR) were used, and categorical variables were expressed as absolute numbers, percentages, and frequencies. Internal consistency was tested using Cronbach’s alpha coefficient for the total questionnaire score. The index ranges from 0 to 1, and higher values indicate greater reliability of the questionnaire. Values between 0.75 and 0.95 were considered appropriate 25 .

Agreement was tested through the standard error of measurement (SEM) and the minimal detectable difference at 90% confidence (MDD90). MDD90 was calculated as (test score 1 - test score 2) / (√2 x SEM) 26,27 . SEM was considered very good if <5% of the total score, good if ≥5% and <10%, questionable if ≥10%, and doubtful if >20% 28 . Additionally, agreement was assessed using the Bland–Altman technique. Reliability was tested through the intraclass correlation coefficient (ICC), using the absolute agreement subtype for single measurements. The variance of each participant’s measurements, rather than the mean, was considered, along with the corresponding 95% confidence interval. The adopted classification was ICC ≤0.4: poor; 0.4 ≤ ICC ≤ 0.75: satisfactory; and ICC ≥0.75: excellent 29 . Convergent validity was analyzed using Pearson’s correlation for parametric variables and Spearman’s correlation for non-parametric variables, correlating the scores of the SF-36 domains with the total score of the DPEBBS. The correlation was characterized as follows: > 0.5, instruments with similar constructs; 0.3 to 0.5, instruments with related constructs; < 0.3, instruments with unrelated constructs 30 . Our hypothesis was that there would be a negative correlation between the questionnaires, with a magnitude <0.3. Ceiling and floor effects were tested by frequency and considered present if 15% or more of the patients achieved the maximum or minimum questionnaire score 28 .

Results

A total of 118 patients were eligible for enrollment, and 112 were included in this study, with 6 patients excluded: 1 due to communication barriers (deafblindness), 1 due to neurological deficits, 2 due to cognitive impairment, 1 due to COVID-19, and 1 for not completing the second DPEBBS assessment.

The descriptive analysis revealed key characteristics of the participants. The mean age was 53.3 years, 61.6% were female, and most participants used a catheter for hemodialysis access (53.6%). The mean number of hospitalizations was 0.31 in the past year and 2.15 over the past five years. Additional descriptive data are presented in Table 1. The mean score in the first DPEBBS administration was 66.97 (SD 7.52), and in the second administration it was 66.96 (SD 7.71) (Table 2).

Table 1. General Characteristics.

Mean (SD) Frequency (%)
Age (years) 53.27 (13.83)
Female 69 (61.6)
Male 43 (38.4)
Catheter Dialysis 60 (53.6)
Fistula Dialysis 52 (46.4)
Height (m) 1.61 (0.10)
BMI 24.13 (3.97)
% Body Fat 31.66 (8.44)
Hemoglobin (g/dL) 12.217 (1.77)
Hematocrit (%) 37.86 (5.17)
Platelets (/mm3) 198500.00
(92511.80)
Creatinine (mg/dL) 10.09 (2.90)

Table 2. Internal consistency, agreement, and reliability.

Test Retest Internal consistency Agreement Reliability
Mean (SD) Mean (SD) Cronbach’s α SEM MDC90 ICC (95%)
Score 66.96 (7.52) 66.80 (7.71) 0.885 4.96% 0.02 (0.16) 0.794 (0.73 –0.85)
Question 1 2.87 (0.76) 2.97 (0.80) –0.01 (–0.09)
Question 2 3.14 (0.69) 3.10 (0.74) 0.005 (0.03)
Question 3 3.14 (0.59) 3.20 (0.64) –0.008 (–0.06)
Question 4 3.30 (0.61) 3.34 (0.66) –0.005 (–0.03)
Question 5 2.98 (0.79) 2.89 (0.83) 0.01 (0.09)
Question 6 3.11 (0.68) 3.16 (0.69) –0.006 (–0.04)
Question 7 3.19 (0.58) 3.26 (0.55) –0.009 (–0.06)
Question 8 1.82 (0.67) 1.79 (0.67) 0.005 (0.03)
Question 9 2.58 (0.91) 2.52 (0.94) 0.008 (0.63)
Question 10 2.84 (0.78) 2.94 (0.79) –0.014 (–0.09)
Question 11 2.74 (0.78) 2.66 (0.88) 0.012 (0.08)
Question 12 2.66 (0.88) 2,48 (0,90) 0.02 (0.18)
Question 13 3.16 (0.65) 3.15 (0.67) 0.001 (0.009)
Question 14 2.25 (0.85) 2.20 (0.91) 0.006 (0.04)
Question 15 2.56 (0.89) 2.51 (0.96) 0.007 (0.04)
Question 16 3.27 (0.83) 3.36 (0.58) –0.01 (–0.09)
Question 17 2.75 (0.90) 2.71 (1.00) 0.006 (0.04)
Question 18 2.71 (0.89) 2.62 (0.97) 0.01 (0.09)
Question 19 2.09 (0.83) 2.02 (0.89) 0.008 (0.06)
Question 20 3.13 (0.67) 3.21 (0.69) –0.01 (–0.08)
Question 21 2.55 (0.85) 2.59 (0.90) –0.005 (–0,03)
Question 22 3.14 (0.61) 3.19 (0.64) –0.006 (–0.04)
Question 23 2.55 (0.80) 2.71 (0.88) –0.02 (–0.15)
Question 24 2.33 (0.92) 2.24 (1.00) 0.01 (0.09)

Abbreviations – SD: Standard deviation; SEM: Standard error of measurement; MDC90: Minimal detectable change at 90% confidence; D: Difference; ICC: Intraclass correlation coefficient; p: Significance; R: Pearson’s correlation coefficient.

Construct validity was assessed by examining correlations between the total DPEBBS score and the domains of the SF-36. Spearman’s correlation coefficients showed weak and predominantly nonsignificant associations across the SF-36 domains, including Physical Functioning (ρ = –0.177, p = 0.063), Role Physical (ρ = –0.205, p = 0.031), Role Emotional (ρ = –0.191, p = 0.045), Vitality (ρ = –0.059, p = 0.542), Mental Health (ρ = –0.076, p = 0.430), Social Functioning (ρ = –0.097, p = 0.311), Bodily Pain (ρ = –0.056, p = 0.559), General Health (ρ = –0.050, p = 0.601), and Health Transition (ρ = 0.008, p = 0.933) (Table 3).

Table 3. Validity with each SF-36 domain.

SF–36 domain ρ p–value
Physical Functioning –0.177 0.063
Role Physical –0.205* 0.031
Role Emotional –0.191* 0.045
Vitality –0.059 0.542
Mental Health –0.076 0.430
Social Functioning –0.097 0.311
Bodily Pain –0.056 0.559
General Health –0.050 0.601
Health Transition 0.008 0.933

Notes – ρ = Spearman’s correlation coefficient.

* p < 0.05.

Convergent and divergent validity hypotheses were tested using Spearman’s correlation between the DPEBBS total score and the Physical Functioning and General Health domains of the SF-36. A weak but statistically significant negative correlation was observed with Physical Functioning (ρ = –0.326, p = 0.001), supporting convergent validity, whereas the correlation with General Health was weak and not statistically significant (ρ = –0.185, p = 0.052), indicating the absence of divergent validity. Although the a priori hypothesis defined convergent validity as a weak negative correlation (|ρ| < 0.30), the observed correlation with Physical Functioning (ρ = –0.326) was slightly higher than expected. Nevertheless, the magnitude of the association remains weak and compatible with the interpretation of related yet distinct constructs, in accordance with the COSMIN recommendations.

The SF-36 scoring analysis revealed the following mean results (Table 4): Physical functioning: 96% (SD 3.38); Role physical: 42% (SD 0.40); Role emotional: 47% (SD 0.43); Vitality: 53% (SD 0.23); Mental health: 68% (SD 0.23); Social functioning: 66% (SD 0.31); Bodily pain: 66% (SD 0.29); General health: 45% (SD 0.18); Health transition: 54% (SD 0.27).

Table 4. SF-36 results.

Score (SD)
Physical Functioning 96% (3.38)
Role Physical 42% (0.40)
Role Emotional 47% (0.43)
Vitality 53% (0.23)
Mental Health 68% (0.23)
Social Functioning 66% (0.31)
Bodily Pain 66% (0.29)
General Health 45% (0.18)
Health Transition 54% (0.27)

Abbreviations – SD: Standard deviation.

The DPEBBS showed high internal consistency (Cronbach’s α = 0.885), very good measurement error (SEM = 4.96% of the total score), and good test–retest reliability (ICC = 0.794, 95% CI 0.73–0.85), with no floor or ceiling effects observed. These results are also illustrated in the Bland–Altman plot (Figure 1). The intraclass correlation coefficient for single measures was 0.794 (95% CI 0.73–0.85), indicating good reliability of the data (Table 2). No ceiling or floor effects were observed.

Figure 1. Bland–Altman graphic.

Figure 1

Discussion

Chronic kidney disease (CKD) represents a significant burden on public health systems worldwide, with its prevalence steadily increasing, especially in low- and middle-income countries such as Brazil 31 . The rise in the number of patients enrolled in dialysis programs highlights the urgent need for effective management strategies tailored to this population 32 . In this study, we aimed to address the shortage of validated tools specifically designed to assess physical activity levels and perceived barriers among CKD patients on dialysis. The Dialysis Patient-Perceived Exercise Benefits and Barriers Scale (DPEBBS) was chosen for validation due to its potential to provide valuable insights into the factors that influence participation in physical activity among dialysis patients. Through rigorous processes of translation and cross-cultural adaptation following the COSMIN guidelines, we ensured the reliability and validity of the scale for use in the Brazilian context.

This study faced significant challenges in translating and culturally adapting a scale from Chinese to Brazilian Portuguese. The linguistic and cultural differences between the languages required meticulous semantic analysis to ensure the equivalence of terms and concepts. Additionally, cultural adaptation was essential to ensure that the scale items accurately reflected the experiences and perceptions of Brazilian patients. The validation process involved a pilot test and feedback from healthcare professionals and patients, resulting in refinements to improve the comprehension and applicability of the scale in the new population. The expertise of translators specialized in medical terminology was crucial in mitigating linguistic inconsistencies and ensuring the consistency of the translation across all scale items. As a result of these efforts, a validated translated version of the scale was obtained, which proved to be effective and reliable for assessing Brazilian patients, thus contributing to a better understanding and treatment of their specific needs.

Data analysis revealed that the scale demonstrated positive characteristics in terms of stability and consistency. The mean test scores were 66.96, while the mean retest scores were 66.80. These similar means indicate good stability of scores over time. The internal consistency of the instrument, measured by Cronbach’s α, was 0.885. This high value suggests that the items are cohesive and consistently measure the same construct. The standard error of measurement (SEM) was 4.96%, which indicates reliable mean scores with little variation. The reliability of the scale was also confirmed by the minimal detectable change at 90% confidence (MDC90) between the test–retest, which was 0.02 (0.16). This indicates that the variation in participants’ responses between measurements was minimal, further reinforcing the instrument’s reliability.

The intraclass correlation coefficient (ICC) was 0.794, with a 95% confidence interval between 0.73 and 0.85. This index confirms good agreement between the measurements, suggesting that the scale is stable when comparing the same individuals’ scores at different times. Regarding validity, most of the correlations found between the DPEBBS and the SF-36 domains were below 0.3, indicating that the constructs are not strongly related. Only the “Role Physical” and “Role Emotional” domains showed weak, statistically significant negative correlations, but still within the category of unrelated constructs, according to the COSMIN classification.

When analyzing the specific items of the scale, the mean responses varied slightly between the test–retest, but the correlations showed minimal variation, indicating high consistency and stability in the responses. In summary, the statistical analysis revealed good internal consistency, reliability, and convergent validity, as well as adequate divergent validity. These characteristics reinforce the robustness of the instrument in assessing the constructs it is intended to measure.

The descriptive data of the participants provide a comprehensive overview of the demographic and clinical characteristics of the sample. The participants’ mean age was 53.27 (±13.83) years, with a mean BMI of 24.13 (±3.97). These values are consistent with typical populations of patients on hemodialysis, despite demographic variations within this population 33,34 . Sex distribution revealed a higher prevalence of female participants at 61.6%, which should be considered when generalizing the results to broader populations 35 . The presented biochemical parameters (such as hemoglobin, hematocrit, creatinine, urea, potassium, phosphorus, calcium, sodium, ferritin, and iron) were within the expected ranges for hemodialysis patients, reflecting the complexity and challenges of managing this condition 36 . The mean number of hospitalizations in recent years is a relevant metric that highlights the disease’s burden and the need for ongoing interventions to maintain the health of these patients, with an average of 0.31 (±0.54) hospitalizations in the last year and 2.15 (±1.93) over the last five years 37,38 .

The analysis of Short Form Health Survey-36 (SF-36) scores revealed notable impairments in various domains of health-related quality of life among the study participants. Role physical, role emotional, and reduced vitality were particularly pronounced, highlighting the multifaceted impact of CKD on patients’ well-being 39 . These findings underscore the importance of addressing not only physical barriers but also psychosocial factors that may influence engagement in physical activity among dialysis patients.

Compared with the original study by Zheng et al., the population in the present study showed some differences that may have influenced the validity values. In the original study, the population was mostly male, and the primary dialysis access was an arteriovenous fistula, whereas in this study, the majority of the participants were female, and the primary dialysis access was a catheter 22 .

Regarding the results obtained when comparing quality of life and the perception of barriers and benefits that dialysis patients have regarding physical activity, our study found results similar to those of Zheng et al., with the main issue being the low quality of life in the evaluated population. However, these individuals still recognized the benefits of physical activity, suggesting that low adherence to exercise and rehabilitation programs may be associated with other factors such as fatigue or fear of injury 9 . The psychometric indices observed for the DPEBBS in this study are also comparable to those reported in previous studies using the DPEBBS and other patient-reported outcome measures in hemodialysis populations 12 . In the study by Ghafourifard et al., the DPEBBS demonstrated satisfactory internal consistency and meaningful associations with patient-reported outcomes, supporting its use in clinical research. Similarly, the DPEBBS showed high internal consistency, good test–retest reliability, and acceptable measurement error, indicating stable and reproducible scores over time. These reliability indices are in line with those commonly reported for widely used instruments in dialysis care, such as the KDQOL-SF and the SF-36, which typically present adequate internal consistency and reproducibility despite measuring broader constructs that are not specific to exercise. Therefore, the DPEBBS demonstrates psychometric performance comparable to established scales used in dialysis settings while offering the advantage of specifically capturing patients’ perceptions of exercise-related benefits and barriers, a construct directly relevant to the planning and evaluation of physical activity interventions in hemodialysis care.

The findings of the present study are largely consistent with those reported by Lightfoot et al. (2021) 14 , who investigated perceptions of exercise benefits and barriers in a large sample of patients undergoing hemodialysis and peritoneal dialysis using the DPEBBS. In both studies, fatigue emerged as one of the most frequently reported barriers, confirming its central role as a limiting factor for exercise participation in this population. Similarly, benefits related to improvements in quality of life, mood, and physical functioning were widely recognized by patients across both contexts, suggesting a consistent perception of the positive effects of exercise. However, differences in the frequency of certain barriers, such as perceptions related to comorbidities and the impact of exercise on family life, were observed between the studies, possibly reflecting variations in clinical profiles, care settings, and study design. Despite these differences, the overall response patterns indicate that patients undergoing dialysis share similar perceptions regarding the main benefits and obstacles to exercise, reinforcing the need for intervention strategies that specifically address fatigue and emphasize benefits perceived as clinically meaningful by the patients themselves.

Wingood et al. highlighted substantial heterogeneity in the assessment of perceived physical activity barriers among adults aged 50 years and older and emphasized the need for populationspecific instruments 21 . Although 33 different tools were identified in the review, most were validated in a single study, and none were developed specifically for patients undergoing dialysis. In this context, the present study fills an important gap by providing a validated Brazilian version of an instrument tailored to the dialysis population. Unlike generic scales such as the Exercise Benefits/Barriers Scale (EBBS), the DPEBBS addresses benefits and barriers directly related to the dialysis treatment context, which may explain the weak but theoretically coherent correlations observed with the SF-36 domains. These results support the view that instruments focused on exercise barriers assess constructs related to, but distinct from, general quality of life and underscore the importance of robust psychometric evaluation in specific clinical populations, particularly in low- and middle-income countries with a high burden of chronic kidney disease.

Future research should focus on evaluating the responsiveness of the DPEBBS in hemodialysis rehabilitation trials, particularly in studies aimed at promoting physical activity and exercise adherence. Longitudinal investigations are also needed to establish clinically meaningful cutoff points, such as scores associated with low exercise participation or poor adherence to rehabilitation programs. Furthermore, the validation of alternative versions of the scale, including electronic formats and adaptations to other languages, may further expand its applicability across different clinical and cultural settings.

Implications for Physiotherapy Practice

The findings of this study suggest that the DPEBBS can be incorporated into clinical practice as a decision-support tool, particularly in the rehabilitation of patients undergoing hemodialysis. Its application enables the identification of patients with a higher perception of barriers to physical activity, facilitating behavioral risk stratification and prioritization of interventions.

Additionally, the instrument may support the development of individualized exercise strategies tailored to patients’ specific needs and perceptions, contributing to more patient-centered approaches. In this context, its use may optimize therapeutic planning, particularly in intradialytic or home-based exercise programs, by integrating both physical and psychosocial factors related to exercise adherence.

Limitations

This study has several limitations that should be considered when interpreting the findings. First, it was conducted in a single hemodialysis center, which may limit the generalizability of the results to other populations and healthcare settings.

Furthermore, the predominance of female participants may have influenced the findings, given potential sex-related differences in the perception of exercise-related benefits and barriers.

The use of the SF-36 as a measure of construct validity, although widely accepted, may not specifically capture exercise-related constructs, which may partially explain the low-magnitude correlations observed.

In addition, the lack of responsiveness assessment limits the understanding of the instrument’s ability to detect changes over time. Finally, the absence of exploratory or confirmatory factor analysis restricts the evaluation of the scale’s dimensional structure within the Brazilian population.

Conclusion

The Brazilian version received the nomenclature “Escala de Percepção da Atividade Física em Diálise (EPAD).”

The EPAD demonstrated adequate validity and reliability for use in dialysis patients, representing a robust instrument for assessing perceived benefits and barriers to physical activity. Despite its satisfactory psychometric properties, limitations such as the single-center design should be considered when interpreting the findings. Nevertheless, the EPAD shows potential for clinical application, supporting individualized exercise counseling and rehabilitation planning in hemodialysis settings, and contributing to more patient-centered care strategies.

Supplementary Material

The following online material is available for this article:

Brazilian Portuguese version of the DPEBBS (196.8KB, pdf) .

Funding Statement

The present publication was funded in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Finance Code 001.

Footnotes

Funding: The present publication was funded in part by the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Finance Code 001.

Data Availability

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  • 1.Levey AS, Coresh J. Chronic kidney disease. Lancet. 2012;379(9811):165–180. doi: 10.1016/S0140-6736(11)60178-5. [DOI] [PubMed] [Google Scholar]
  • 2.Universidade Federal do Maranhão . Modalidades de terapia renal substitutiva: hemodiálise e diálise peritoneal. São Luís: UNA-SUS/UFMA; 2016. UNA-SUS/UFMA. [Google Scholar]
  • 3.Mehrotra R, Chiu YW, Kalantar-Zadeh K, Bargman J, Vonesh E. Similar outcomes with hemodialysis and peritoneal dialysis in patients with end-stage renal disease. Arch Intern Med. 2011;171(2):110–118. doi: 10.1001/archinternmed.2010.352. [DOI] [PubMed] [Google Scholar]
  • 4.Brasil . Departamento de Análise de Situações de Saúde. Instituto Brasileiro de Geografia e Estatística. Diretoria de Pesquisas. Coordenação de Trabalho e Rendimento. Fundação Oswaldo Cruz. Instituto de Comunicação e Informação Científica e Tecnológica em Saúde. Pesquisa Nacional de Saúde. Percepção do estado de saúde, estilos de vida e doenças crônicas: Brasil, Grandes Regiões e Unidades de Federação. Rio de Janeiro: IBGE; 2014. Ministério de Saúde. [Google Scholar]
  • 5.United States Renal Data System . 2020 USRDS Annual Data Report: epidemiology of kidney disease in the United States. Bethesda, MD: National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases; 2020. [Google Scholar]
  • 6.Bikbov B, Purcell CA, Levey AS, Smith M, Abdoli A, Abebe M, et al. the GBD Chronic Kidney Disease Collaboration. Global, regional, and national burden of chronic kidney disease, 1990-2017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet. 2020;395(10225):709–733. doi: 10.1016/S0140-6736(20)30045-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.World Health Organization . Global surveillance, prevention and control of chronic respiratory diseases: a comprehensive approach. Geneva: WHO; 2007. The Global Alliance against Chronic Respiratory Diseases. [Google Scholar]
  • 8.Strong K, Mathers C, Leeder S, Beaglehole R. Preventing chronic diseases: how many lives can we save? Lancet. 2005;366(9496):1578–1582. doi: 10.1016/S0140-6736(05)67341-2. [DOI] [PubMed] [Google Scholar]
  • 9.Ghafourifard M, Mehrizade B, Hassankhani H, Heidari M. Hemodialysis patients perceived exercise benefits and barriers: the association with health-related quality of life. BMC Nephrol. 2021;22(1):94. doi: 10.1186/s12882-021-02292-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Moorman D, Suri R, Hiremath S, Jegatheswaran J, Kumar T, Bugeja A, et al. Benefits and barriers to and desired outcomes with exercise in patients with ESKD. Clin J Am Soc Nephrol. 2019;14(2):268–276. doi: 10.2215/CJN.09700818. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Liu C, Yang J, Li H, Deng Y, He P, Zhang J, et al. Comparative efficacy of exercise modalities for general risk factors, renal function, and physical function in non-dialysis chronic kidney disease patients: a systematic review and network meta-analysis. Ren Fail. 2024;46(2):2373272. doi: 10.1080/0886022X.2024.2373272. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Liu Y, Lee DC, Li Y, Zhu W, Zhang R, Sui X, et al. Associations of resistance exercise with cardiovascular disease morbidity and mortality. Med Sci Sports Exerc. 2019;51(3):499–508. doi: 10.1249/MSS.0000000000001822. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Agarwal M, Alexiuk J, Bohm C, Sikora L, Zimmerman D. Factors influencing recruitment, retention, and adherence rates in exercise interventions in ESKD: a scoping review. Kidney Med. 2024;7(1):100933. doi: 10.1016/j.xkme.2024.100933. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Lightfoot CJ, Wilkinson TJ, Song Y, Burton JO, Smith AC. Perceptions of exercise benefits and barriers: the influence on physical activity behaviour in individuals undergoing haemodialysis and peritoneal dialysis. J Nephrol. 2021;34(6):1961–1971. doi: 10.1007/s40620-021-01024-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Jhamb M, McNulty ML, Ingalsbe G, Childers JW, Schell J, Conroy MB, et al. Knowledge, barriers and facilitators of exercise in dialysis patients: a qualitative study of patients, staff and nephrologists. BMC Nephrol. 2016;17(1):192. doi: 10.1186/s12882-016-0399-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Jones SA, Wen F, Herring AH, Evenson KR. Correlates of US adult physical activity and sedentary behavior patterns. J Sci Med Sport. 2016;19(12):1020–1027. doi: 10.1016/j.jsams.2016.03.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Molanorouzi K, Khoo S, Morris T. Motives for adult participation in physical activity: type of activity, age, and gender. BMC Public Health. 2015;15(1):66. doi: 10.1186/s12889-015-1429-7. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Rampersad C, Brar R, Connelly K, Komenda P, Rigatto C, Prasad B, et al. Association of physical activity and poor health outcomes in patients with advanced CKD. Am J Kidney Dis. 2021;78(3):391–398. doi: 10.1053/j.ajkd.2020.12.018. [DOI] [PubMed] [Google Scholar]
  • 19.Ainsworth B, Cahalin L, Buman M, Ross R. The current state of physical activity assessment tools. Prog Cardiovasc Dis. 2015;57(4):387–395. doi: 10.1016/j.pcad.2014.10.005. [DOI] [PubMed] [Google Scholar]
  • 20.Painter P, Marcus RL. Assessing physical function and physical activity in patients with CKD. Clin J Am Soc Nephrol. 2013;8(5):861–872. doi: 10.2215/CJN.06590712. [DOI] [PubMed] [Google Scholar]
  • 21.Wingood M, Criss MG, Irwin KE, Bamonti PM, Harris R, Phillips EL, et al. Examining physical activity participation barriers among adults 50 years and older: a scoping review. Phys Ther Rev. 2023;28(3):195–210. doi: 10.1080/10833196.2023.2265767. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Zheng J, You LM, Lou TQ, Chen NC, Lai DY, Liang YY, et al. Development and psychometric evaluation of the Dialysis patient-perceived Exercise Benefits and Barriers Scale. Int J Nurs Stud. 2010;47(2):166–180. doi: 10.1016/j.ijnurstu.2009.05.023. [DOI] [PubMed] [Google Scholar]
  • 23.Boparai JK, Singh S, Kathuria P. How to design and validate a questionnaire: a guide. Curr Clin Pharmacol. 2018;13(4):210–215. doi: 10.2174/1574884713666180807151328. [DOI] [PubMed] [Google Scholar]
  • 24.Terwee CB, Mokkink LB, Knol DL, Ostelo RW, Bouter LM, de Vet HC. Rating the methodological quality in systematic reviews of studies on measurement properties: a scoring system for the COSMIN checklist. Qual Life Res. 2012;21(4):651–657. doi: 10.1007/s11136-011-9960-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Tavakol M, Dennick R. Making sense of Cronbachs alpha. Int J Med Educ. 2011;2:53–55. doi: 10.5116/ijme.4dfb.8dfd. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Terwee CB, Mokkink LB, van Poppel MN, Chinapaw MJ, van Mechelen W, de Vet HC. Qualitative attributes and measurement properties of physical activity questionnaires: a checklist. Sports Med. 2010;40(7):525–537. doi: 10.2165/11531370-000000000-00000. [DOI] [PubMed] [Google Scholar]
  • 27.De Vet HCWTC, Mokkink LB, Knol DL. Measurement in medicine. 1. New York: Cambridge University Press; 1995. [Google Scholar]
  • 28.Streiner DLNG. Health Measurement Scales: a practical guide to their development and use. 2. New York: Oxford University Press; 1995. [Google Scholar]
  • 29.Ostelo RW, de Vet HC, Knol DL, van den Brandt PA. 24-item Roland-Morris Disability Questionnaire was preferred out of six functional status questionnaires for post-lumbar disc surgery. J Clin Epidemiol. 2004;57(3):268–276. doi: 10.1016/j.jclinepi.2003.09.005. [DOI] [PubMed] [Google Scholar]
  • 30.Cohen J. Statistical power analysis for the behavioral sciences. 2. New Jersey: LEA; 1988. [Google Scholar]
  • 31.Aguiar LK, Prado RR, Gazzinelli A, Malta DC. Factors associated with chronic kidney disease: epidemiological survey of the National Health Survey. Rev Bras Epidemiol. 2020;23:e200044. doi: 10.1590/1980-549720200044. [DOI] [PubMed] [Google Scholar]
  • 32.Himmelfarb J, Vanholder R, Mehrotra R, Tonelli M. The current and future landscape of dialysis. Nat Rev Nephrol. 2020;16(10):573–585. doi: 10.1038/s41581-020-0315-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Souza MAH, Holanda R, Martins ETJ, Hoffmeister AC, Capellari C. Patient profile in hemodialysis from a referral service in Rio Grande do Sul, Brazil. Res Soc Dev. 2022;11(1):e41611125025. doi: 10.33448/rsd-v11i1.25025. [DOI] [Google Scholar]
  • 34.Cherchiglia ML, Machado EL, Szuster DA, Andrade EI, Assis Acúrcio F, Caiaffa WT, et al. Epidemiological profile of patients on renal replacement therapy in Brazil, 2000-2004. Rev Saude Publica. 2010;44(4):639–649. doi: 10.1590/S0034-89102010000400007. [DOI] [PubMed] [Google Scholar]
  • 35.Carrero JJ, Hecking M, Chesnaye NC, Jager KJ. Sex and gender disparities in the epidemiology and outcomes of chronic kidney disease. Nat Rev Nephrol. 2018;14(3):151–164. doi: 10.1038/nrneph.2017.181. [DOI] [PubMed] [Google Scholar]
  • 36.Yoon SY, Kim JS, Jeong KH, Kim SK. Acute kidney injury: biomarker-guided diagnosis and management. Medicina. 2022;58(3):340. doi: 10.3390/medicina58030340. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Fink JC. Are ambulatory care-sensitive conditions the fulcrum of hospitalizations for CKD patients? Clin J Am Soc Nephrol. 2016;11(11):1927–1928. doi: 10.2215/CJN.09160816. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.Ronksley PE, Hemmelgarn BR, Manns BJ, Wick J, James MT, Ravani P, et al. Potentially preventable hospitalization among patients with CKD and high inpatient use. Clin J Am Soc Nephrol. 2016;11(11):2022–2031. doi: 10.2215/CJN.04690416. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Chen CP, Lee SY, Tsay SL, Tung HH. Resilience, activities of daily living, and well-being in patients with chronic kidney disease. Nurs Open. 2023;10(12):7759–7766. doi: 10.1002/nop2.2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
J Bras Nefrol. 2026 May 11;48(3):e20250199. [Article in Portuguese] doi: 10.1590/2175-8239-JBN-2025-0199pt

Tradução, adaptação transcultural e validação psicométrica da versão brasileira da escala de benefícios e barreiras ao exercício percebidos por pacientes em diálise

Graziella Alves da Silva 1, Cid André Fidelis de Paula Gomes 1, Thamiê Cristina Stella 1, Barbara G Miura 1, Jing Zheng 2, Renato D Foresto 3, Renata Kelly de Palma 4, Almir V Dibai-Filho 5, Luciana Maria Malosá Sampaio 1

Resumo

Introdução:

A doença renal crônica (DRC) em diálise compromete a saúde musculoesquelética e reduz os níveis de atividade física. A Dialysis Patient-Perceived Exercise Benefits and Barriers Scale (DPEBBS) foi desenvolvida especificamente para avaliar as percepções dos pacientes em diálise sobre o exercício. Este estudo teve como objetivo traduzir, adaptar transculturalmente e avaliar as propriedades psicométricas da versão brasileira da DPEBBS (EPAD).

Métodos:

Foi conduzido um estudo transversal, seguindo as diretrizes do COSMIN. As propriedades psicométricas avaliadas incluíram confiabilidade, consistência interna e validade de construto. Os participantes foram recrutados no setor de hemodiálise da Unifesp. Um total de 112 adultos em diálise respondeu à DPEBBS, ao Short Form Health Survey-36 (SF-36), e foi submetido à avaliação antropométrica. O intervalo entre o teste e o reteste foi de uma semana. Análises descritivas e inferenciais foram realizadas para testar a validade e a confiabilidade.

Resultados:

A escala demonstrou alta estabilidade teste–reteste, com médias consistentes entre as avaliações. A consistência interna foi alta, e a confiabilidade foi sustentada por uma mínima mudança detectável baixa e por um alto coeficiente de correlação intraclasse. A validade convergente com o domínio Capacidade Funcional do SF-36 foi fraca, porém estatisticamente significativa (r = –0,326; p = 0,001), enquanto a correlação com o domínio Estado Geral de Saúde foi fraca e não estatisticamente significativa (r = –0,185; p = 0,052). A análise de consistência mostrou α = 0,885, ICC = 0,794, SEM = 4,96%, e demonstrou ausência de efeitos de piso e teto.

Conclusão:

A EPAD apresentou validade e confiabilidade robustas para pacientes em diálise. Apesar da adequada confiabilidade e validade, este estudo apresenta limitações, incluindo uma amostra de centro único. A EPAD pode apoiar o aconselhamento individualizado para o exercício e o planejamento da reabilitação em unidades de hemodiálise.

Descritores: Insuficiência Renal Crônica, Diálise Renal, Exercício Físico, Inquéritos e Questionários

Introdução

A doença renal crônica (DRC) é definida como anormalidades na estrutura ou na função renal, com duração superior a três meses, sendo classificada em cinco estágios, de acordo com o nível de redução da taxa de filtração glomerular (TFG). Nos estágios avançados, quando a TFG cai abaixo de 15 mL/min/1,73 m2, os pacientes evoluem para doença renal em estágio terminal e necessitam de terapia renal substitutiva (TRS), que inclui o transplante renal ou a diálise 1,2 . A diálise pode ser realizada por meio de diálise peritoneal ou hemodiálise, sendo a escolha da modalidade dependente da condição clínica e do estilo de vida e não da superioridade de um método em relação ao outro 3 .

Atualmente, a DRC constitui um importante problema de saúde pública no Brasil, com aumento exponencial da prevalência de pacientes inseridos em programas de diálise nos últimos anos. O número de pacientes em diálise mais que dobrou entre 1994 e 2004, passando de 24.000 pacientes em 1994 para 59.153 em 2004, com crescimento anual da incidência de novos pacientes em torno de 8% 4 . Entre 2017 e 2018, o número de pacientes renais com acesso ao tratamento aumentou em 98% no Brasil em comparação ao período de 2007 a 2009 5 . A comparação dos dados brasileiros com estatísticas globais reforça a relevância de políticas voltadas à prevenção e ao tratamento da DRC, especialmente no contexto de países de baixa e média renda, onde a carga da doença é desproporcionalmente maior. A DRC também está fortemente associada às doenças cardiovasculares, contribuindo para 1,4 milhão de óbitos relacionados ao coração e 25,3 milhões de anos de vida ajustados por incapacidade (Disability-Adjusted Life Years – DALYs) atribuídos à disfunção renal. Essas informações evidenciam a necessidade de maior atenção global à DRC, particularmente em regiões como a América Latina, onde a carga da doença é superior à esperada para o nível de desenvolvimento socioeconômico 6 .

As doenças crônicas são a principal causa de morte prematura em adultos em todo o mundo, especialmente em países de baixa e média renda, onde ocorrem 80% desses óbitos. Estima-se que, em 2005, as doenças crônicas foram responsáveis por 35 milhões (60%) de um total de 58 milhões de óbitos por todas as causas 7,8 . Entre elas, destaca-se a doença renal crônica, cujos principais fatores desencadeantes são a hipertensão arterial sistêmica, o diabetes e a dislipidemia 5 , reforçando a importância do acompanhamento multidisciplinar desses pacientes. Entre as diversas complicações associadas à DRC estão a incapacidade física, a fraqueza, a redução da qualidade de vida e o aumento do risco de morte por eventos cardiovasculares 9,10 .

Os gastos públicos associados ao tratamento crônico da DRC em diálise também representam uma preocupação, uma vez que há grande utilização de recursos em saúde, incluindo consultas, hospitalizações e terapia renal substitutiva (TRS) 1 .

Está bem estabelecido que a atividade física proporciona benefícios substanciais para pacientes com doença renal crônica, particularmente aqueles em tratamento dialítico 11 . O exercício regular está associado a melhorias na saúde musculoesquelética, na função física, na fadiga, na qualidade de vida e na aptidão cardiorrespiratória, podendo também contribuir para a redução da morbimortalidade cardiovascular 12 . Apesar desse robusto corpo de evidências, a maioria dos pacientes em diálise permanece insuficientemente ativa, e a adesão a programas de exercício e reabilitação é consistentemente baixa 13 .

Diversos fatores contribuem para os baixos níveis de atividade física observados nessa população. Entre os determinantes mais frequentemente relatados estão as barreiras percebidas, como fadiga, medo de lesões, comorbidades e limitações físicas, além da falta de conhecimento ou compreensão sobre os benefícios específicos do exercício. Adicionalmente, o aconselhamento e o incentivo insuficientes por parte dos profissionais de saúde podem limitar ainda mais o engajamento em atividades físicas 14,15 . Fatores sociodemográficos, como idade e sexo, bem como o tipo e o contexto da atividade física, também desempenham papel importante na participação de adultos em geral e de pacientes em diálise em particular 16 .

Embora essas barreiras e determinantes sejam amplamente reconhecidos, sua avaliação sistemática em contextos clínicos e de pesquisa ainda representa um desafio. Apesar da disponibilidade de diversos questionários genéricos de atividade física 17 , poucos instrumentos foram especificamente desenvolvidos e validados psicometricamente para a população em diálise. Isso representa uma lacuna importante, uma vez que pacientes em diálise apresentam características clínicas, restrições relacionadas ao tratamento e percepções singulares que podem não ser adequadamente captadas por instrumentos genéricos. Dessa forma, a disponibilidade de instrumentos válidos e confiáveis, específicos para pacientes em diálise, é essencial para melhor compreender o comportamento em relação à atividade física e identificar barreiras modificáveis. Além disso, esses instrumentos podem apoiar o aconselhamento individualizado para o exercício e o planejamento da reabilitação nessa população 9,10,14 .

Diferentes escalas e questionários têm como objetivo mensurar os níveis de atividade física em adultos, além de estabelecer propostas eficazes de atividades com maiores taxas de adesão, e isso não é diferente para pacientes com doença renal crônica 18 . Atualmente, diversas escalas e questionários avaliam os níveis de atividade física e as barreiras potenciais enfrentadas pela população adulta para a prática de atividades físicas; contudo, é fundamental que essa avaliação seja realizada especificamente em pacientes com DRC, considerando suas particularidades. Nesse contexto, os instrumentos disponíveis para essa finalidade são muito mais escassos 19,20 .

Diante da persistente baixa adesão ao exercício entre pacientes em diálise e do papel central dos benefícios e barreiras percebidos na determinação do comportamento em relação à atividade física, o uso de instrumentos que capturem especificamente esses construtos é essencial 21 . A Dialysis Patients’ Exercise Benefits and Barriers Scale (DPEBBS) 22 foi desenvolvida na China para avaliar as percepções de pacientes em diálise quanto aos benefícios do exercício e às barreiras que limitam sua prática, abordando dimensões diretamente relevantes para essa população e não plenamente contempladas por questionários genéricos de atividade física. Assim, a DPEBBS representa uma ferramenta apropriada e clinicamente relevante para avaliar determinantes-chave do comportamento de exercício em pacientes em diálise, apoiando tanto a pesquisa quanto o aconselhamento individualizado para o exercício e o planejamento da reabilitação.

Escalas desenvolvidas para outras populações ou em outros idiomas precisam ser validadas para que possam ser utilizadas de forma segura e reprodutível quando aplicadas em diferentes línguas e culturas. Como a DPEBBS foi originalmente desenvolvida na China, são necessárias a tradução, a adaptação transcultural e a validação para garantir sua equivalência conceitual, confiabilidade e validade para uso em diferentes contextos linguísticos e culturais. Estudos de validação de instrumentos disponíveis para diversas avaliações têm se mostrado eficazes no auxílio à avaliação e ao tratamento de pacientes com diferentes condições de saúde e doença 23 . Este estudo teve como objetivo traduzir e adaptar transculturalmente a DPEBBS para o português brasileiro e avaliar suas propriedades psicométricas em pacientes adultos em hemodiálise.

Métodos

Desenho do Estudo e Participantes

Foi conduzido um estudo transversal por meio da aplicação da DPEBBS, do SF-36 e de uma avaliação antropométrica, seguindo as diretrizes do COSMIN para garantir a mensuração confiável das propriedades da escala. Essas diretrizes fornecem diferentes classificações com base no tamanho amostral, sendo uma amostra com ≥100 participantes classificada como “very good”. 24 Essa classificação visa avaliar a consistência interna, a concordância, a confiabilidade e a validade convergente de um questionário em processo de validação e adaptação transcultural.

A análise fatorial não foi realizada no presente estudo porque a estrutura fatorial da DPEBBS já foi estabelecida no instrumento original por meio de análises fatoriais exploratória e confirmatória. Considerando que o objetivo principal foi a adaptação transcultural e a avaliação da confiabilidade e validade, a estrutura previamente validada foi mantida; portanto, um tamanho amostral mínimo de 100 participantes foi considerado adequado.

Para inclusão no estudo, os participantes deveriam ter diagnóstico de DRC dependente de diálise, idade lise, idade 18 anos e estar clinicamente estáveis (ausência de eventos cardiovasculares, mudanças na medicação ou no regime dialítico nas quatro semanas anteriores e estado geral de saúde estável). Foram excluídos indivíduos que não aderiam à diálise, bem como aqueles com outras doenças ou condições físicas que impedissem a realização dos testes e exames devido a limitações musculoesqueléticas ou cognitivas.

Os pacientes foram recrutados no Departamento de Hemodiálise do Hospital Rim – Fundação Oswaldo Ramos – Universidade Federal de São Paulo (Unifesp). Após a explicação do estudo e dos procedimentos e a assinatura do Termo de Consentimento Livre e Esclarecido (TCLE), os participantes foram submetidos à avaliação antropométrica e preencheram o SF-36 e a DPEBBS.

Tradução e Adaptação Transcultural

A tradução e a adaptação transcultural da DPEBBS seguiram as recomendações internacionais estabelecidas para a adaptação de instrumentos relacionados à saúde. A escala original, desenvolvida em chinês, foi inicialmente traduzida para o português por um médico brasileiro fluente em chinês, com experiência clínica em cuidados dialíticos e familiaridade com conceitos relacionados ao exercício físico.

Subsequentemente, a versão em português foi retrotraduzida para o chinês por um médico chinês nativo fluente em português, que estava cego à versão original do instrumento e não teve acesso ao seu conteúdo. A versão retrotraduzida foi comparada com a escala original em chinês para avaliar a equivalência semântica, idiomática e conceitual. Um terceiro tradutor, fluente em chinês e português e sem vínculo com a área da saúde, avaliou termos que pudessem dificultar a compreensão pelos pacientes.

Foi realizado um pré-teste com 10 pacientes em diálise para avaliar clareza, compreensão e adequação cultural do instrumento traduzido. Não foram identificadas dificuldades na compreensão dos itens ou das opções de resposta, e nenhuma modificação foi necessária após o pré-teste. A aplicação piloto da escala foi realizada por fisioterapeutas, que também relataram não haver dificuldades na administração do instrumento.

Por fim, a versão retrotraduzida foi enviada à School of Nursing da Sun Yat-sen University, detentora dos direitos autorais da DPEBBS, que sugeriu pequenos ajustes na redação. Essas recomendações foram incorporadas à versão final da escala em português, que foi posteriormente aplicada à amostra total do estudo.

A escala foi aplicada duas vezes aos participantes para avaliação da confiabilidade teste-reteste, com intervalo de uma semana entre as avaliações. Esse intervalo é suficientemente curto para evitar mudanças clínicas, mas longo o suficiente para minimizar a recordação das respostas anteriores. Apenas pacientes clinicamente estáveis foram reavaliados para a confiabilidade teste-reteste, de acordo com os critérios de estabilidade previamente definidos.

Análise Estatística

A análise dos dados foi realizada utilizando o software SPSS (versão 26.0; SPSS Inc.; Chicago, Illinois, EUA). O teste de Shapiro–Wilk foi utilizado para determinar a normalidade dos dados. Na análise descritiva, as variáveis paramétricas foram expressas como média e desvio-padrão (DP). Para variáveis não paramétricas, foram utilizadas mediana e intervalo interquartil, e as variáveis categóricas foram expressas em números absolutos, porcentagens e frequências.

A consistência interna foi testada por meio do coeficiente alfa de Cronbach para o escore total do questionário. O índice varia de 0 a 1, sendo valores mais elevados indicativos de maior confiabilidade do questionário. Valores entre 0,75 e 0,95 foram considerados apropriados 25 .

A concordância foi testada por meio do erro padrão de medição (SEM) e da diferença mínima detectável com 90% de confiança (MDD90). A MDD90 foi calculada como: (escore do teste 1 - escore do teste 2) / (√2 × SEM) 26,27 . O SEM foi considerado muito bom se <5% do escore total, bom se ≥5% e <10%, questionável se ≥10% e duvidoso se >20% 28 .

Adicionalmente, a concordância do instrumento foi avaliada por meio da técnica de Bland–Altman. A confiabilidade foi testada utilizando o coeficiente de correlação intraclasse (ICC), subtipo concordância absoluta para medidas únicas. Foi considerada a variância das medidas de cada participante, e não a média, juntamente com o respectivo intervalo de confiança de 95%. A classificação adotada foi: ICC ≤0,4: fraca; 0,4 ≤ ICC ≤ 0,75: satisfatória; e ICC ≥0,75: excelente 29 .

A validade convergente foi analisada utilizando a correlação de Pearson para variáveis paramétricas e a correlação de Spearman para variáveis não paramétricas, correlacionando os escores dos domínios do SF-36 com o escore total da DPEBBS. A correlação foi caracterizada como: >0,5, instrumentos com construtos semelhantes; 0,3 a 0,5, instrumentos com construtos relacionados; <0,3, instrumentos com construtos não relacionados 30 . A hipótese estabelecida foi a de existência de correlação negativa entre os questionários, com magnitude <0,3.

Os efeitos teto e piso foram testados por frequência e considerados presentes se 15% ou mais dos pacientes atingissem o escore máximo ou mínimo do questionário 28 .

Resultados

Um total de 118 pacientes foi considerado elegível para participação, dos quais 112 foram incluídos neste estudo, com 6 exclusões: 1 devido a barreiras de comunicação (surdez e cegueira), 1 por déficits neurológicos, 2 por comprometimento cognitivo, 1 por COVID-19 e 1 por não ter completado a segunda aplicação da DPEBBS.

A análise descritiva revelou características-chave dos participantes. A idade média foi de 53,3 anos, 61,6% eram do sexo feminino e a maioria utilizava cateter como acesso para hemodiálise (53,6%). O número médio de hospitalizações foi de 0,31 no último ano e de 2,15 nos últimos cinco anos. Dados descritivos adicionais estão apresentados na Tabela 1.

Tabela 1. Características gerais.

Média (DP) Frequência (%)
Idade (anos) 53,27 (13,83)
Feminino 69 (61,6)
Masculino 43 (38,4)
Cateter de Diálise 60 (53,6)
Fistula de Diálise 52 (46,4)
Altura (m) 1,61 (0,10)
IMC 24,13 (3,97)
% Gordura Corporal 31,66 (8,44)
Hemoglobina (g/dL) 12,217 (1,77)
Hematócrito (%) 37,86 (5,17)
Plaquetas (/mm3) 198500,00
(92511,80)
Creatinina (mg/dL) 10,09 (2,90)

A pontuação média na primeira aplicação da DPEBBS foi de 66,97 (DP 7,52) e, na segunda aplicação, de 66,96 (DP 7,71) (Tabela 2).

Tabela 2. Consistência interna, concordância e confiabilidade.

Teste Reteste Consistência Interna Concordância Confiabilidade
Média (DP) Média (DP) α Cronbach SEM MDD90 ICC (95%)
Pontuação 66,96 (7,52) 66,80 (7,71) 0,885 4,96% 0,02 (0,16) 0,794 (0,73–0,85)
Questão 1 2,87 (0,76) 2,97 (0,80) –0,01 (–0,09)
Questão 2 3,14 (0,69) 3,10 (0,74) 0,005 (0,03)
Questão 3 3,14 (0,59) 3,20 (0,64) –0,008 (–0,06)
Questão 4 3,30 (0,61) 3,34 (0,66) –0,005 (–0,03)
Questão 5 2,98 (0,79) 2,89 (0,83) 0,01 (0,09)
Questão 6 3,11 (0,68) 3,16 (0,69) –0,006 (–0,04)
Questão 7 3,19 (0,58) 3,26 (0,55) –0,009 (–0,06)
Questão 8 1,82 (0,67) 1,79 (0,67) 0,005 (0,03)
Questão 9 2,58 (0,91) 2,52 (0,94) 0,008 (0,63)
Questão 10 2,84 (0,78) 2,94 (0,79) –0,014 (–0,09)
Questão 11 2,74 (0,78) 2,66 (0,88) 0,012 (0,08)
Questão 12 2,66 (0,88) 2,48 (0,90) 0,02 (0,18)
Questão 13 3,16 (0,65) 3,15 (0,67) 0,001 (0,009)
Questão 14 2,25 (0,85) 2,20 (0,91) 0,006 (0,04)
Questão 15 2,56 (0,89) 2,51 (0,96) 0,007 (0,04)
Questão 16 3,27 (0,83) 3,36 (0,58) –0,01 (–0,09)
Questão 17 2,75 (0,90) 2,71 (1,00) 0,006 (0,04)
Questão 18 2,71 (0,89) 2,62 (0,97) 0,01 (0,09)
Questão 19 2,09 (0,83) 2,02 (0,89) 0,008 (0,06)
Questão 20 3,13 (0,67) 3,21 (0,69) –0,01 (–0,08)
Questão 21 2,55 (0,85) 2,59 (0,90) –0,005 (–0,03)
Questão 22 3,14 (0,61) 3,19 (0,64) –0,006 (–0,04)
Questão 23 2,55 (0,80) 2,71 (0,88) –0,02 (–0,15)
Questão 24 2,33 (0,92) 2,24 (1,00) 0,01 (0,09)

Abreviaturas – DP: Desvio padrão; SEM: Erro padrão de medição; MDD90: Diferença mínima detectável em 90% de confiança; ICC: Coeficiente de correlação intraclasse; p: Significância; R: Coeficiente de correlação de Pearson.

A validade de construto foi avaliada por meio da análise das correlações entre o escore total da DPEBBS e os domínios do SF-36. Os coeficientes de correlação de Spearman demonstraram associações fracas e predominantemente não significativas entre os domínios do SF-36, incluindo: Capacidade Funcional (ρ = –0,177; p = 0,063), Limitação por Aspectos Físicos (ρ = –0,205; p = 0,031), Limitação por Aspectos Emocionais (ρ = –0,191; p = 0,045), Vitalidade (ρ = –0,059; p = 0,542), Saúde Mental (ρ = –0,076; p = 0,430), Aspectos Sociais (ρ = –0,097; p = 0,311), Dor Corporal (ρ = –0,056; p = 0,559), Estado Geral de Saúde (ρ = –0,050; p = 0,601) e Transição de Saúde (ρ = 0,008; p = 0,933) (Tabela 3).

Tabela 3. Validade com cada domÍnio do SF-36.

Domínios do SF-36 ρ Valor de p
Capacidade Funcional –0,177 0,063
Limitações por Aspectos Físicos –0,205* 0,031
Limitações por Aspectos Emocionais –0,191* 0,045
Vitalidade –0,059 0,542
Saúde Mental –0,076 0,430
Aspectos Sociais –0,097 0,311
Dor Corporal –0,056 0,559
Estado Geral de Saúde –0,050 0,601
Transição de Saúde 0,008 0,933

Notas – ρ = Coeficiente de correlação de Spearman;

* p < 0.05.

As hipóteses de validade convergente e divergente foram testadas por meio da correlação de Spearman entre os escores da DPEBBS e os domínios Capacidade Funcional e Estado Geral de Saúde do SF-36. Observou-se uma correlação negativa fraca, porém estatisticamente significativa, com o domínio Capacidade Funcional (ρ = –0,326; p = 0,001), sustentando a validade convergente. Em contrapartida, a correlação com o domínio Estado Geral de Saúde foi fraca e não estatisticamente significativa (ρ = –0,185; p = 0,052), indicando ausência de validade divergente.

Embora a hipótese a priori tenha definido a validade convergente como uma correlação negativa fraca (|ρ| < 0,30), a correlação observada com o domínio Capacidade Funcional (ρ = –0,326) foi ligeiramente superior ao esperado. Ainda assim, a magnitude da associação permanece fraca e compatível com a interpretação de construtos relacionados, porém distintos, de acordo com as recomendações do COSMIN.

A análise dos escores do SF-36 revelou os seguintes valores médios (Tabela 4): Capacidade Funcional: 96% (DP 3,38); Limitações Físicas: 42% (DP 0,40); Limitações Emocionais: 47% (DP 0,43); Vitalidade: 53% (DP 0,23); Saúde Mental: 68% (DP 0,23); Aspectos Sociais: 66% (DP 0,31); Dor: 66% (DP 0,29); Estado Geral de Saúde: 45% (DP 0,18); Mudança no Estado de Saúde: 54% (DP 0,27).

Tabela 4. Resultados do SF-36.

Pontuação (DP)
Capacidade Funcional 96% (3,38)
Limitações por Aspectos Físicos 42% (0,40)
Limitações por Aspectos Emocionais 47% (0,43)
Vitalidade 53% (0,23)
Saúde Mental 68% (0,23)
Aspectos Sociais 66% (0,31)
Dor Corporal 66% (0,29)
Estado Geral de Saúde 45% (0,18)
Transição de Saúde 54% (0,27)

Abreviaturas – DP: Desvio padrão.

A DPEBBS apresentou alta consistência interna (alfa de Cronbach = 0,885), erro de medição muito bom (SEM = 4,96% do escore total) e boa confiabilidade teste-reteste (ICC = 0,794; IC95%: 0,73–0,85), sem efeitos teto ou piso observados. Esses resultados também são demonstrados no gráfico de Bland–Altman (Figura 1).

Figura 1. Gráfico de Bland–Altman .

Figura 1

O coeficiente de correlação intraclasse para medidas únicas foi de 0,794 (IC95%: 0,73–0,85), indicando boa confiabilidade dos dados (Tabela 2). Não foram observados efeitos teto ou piso.

Discussão

A doença renal crônica (DRC) representa um fardo significativo para os sistemas de saúde pública em todo o mundo, com prevalência em crescimento contínuo, especialmente em países de baixa e média renda, como o Brasil 31 . O aumento no número de pacientes incluídos em programas de diálise evidencia a necessidade urgente de estratégias eficazes de manejo voltadas especificamente para essa população 32 . Nesse contexto, o presente estudo teve como objetivo suprir a escassez de instrumentos validados destinados a avaliar níveis de atividade física e barreiras percebidas entre pacientes com DRC em diálise. A Perceived Exercise Benefits and Barriers Scale for Dialysis Patients (DPEBBS) foi selecionada para validação devido ao seu potencial de fornecer informações relevantes sobre os fatores que influenciam a participação em atividade física entre pacientes em diálise. Por meio de um rigoroso processo de tradução e adaptação, conduzido de acordo com as diretrizes do COSMIN, foram garantidas a confiabilidade e a validade da escala para uso no contexto brasileiro.

Este estudo enfrentou desafios significativos no processo de tradução e adaptação transcultural de uma escala originalmente desenvolvida em língua chinesa para o português brasileiro. As diferenças linguísticas e culturais entre os idiomas exigiram uma análise semântica minuciosa para assegurar a equivalência dos termos e conceitos. Além disso, a adaptação cultural foi fundamental para garantir que os itens da escala refletissem com precisão as experiências e percepções dos pacientes brasileiros. O processo de validação envolveu um teste piloto e a coleta de feedback de profissionais de saúde e pacientes, resultando em ajustes refinados para aprimorar a compreensão e a aplicabilidade da escala na nova população. A atuação de tradutores com expertise em terminologia médica foi essencial para minimizar inconsistências linguísticas e assegurar a uniformidade da tradução em todos os itens da escala. Como resultado desses esforços, obteve-se uma versão traduzida e validada da escala, eficaz e confiável para a avaliação de pacientes brasileiros, contribuindo para uma melhor compreensão e manejo de suas necessidades específicas.

A análise dos dados revelou que o instrumento apresenta características positivas em termos de estabilidade e consistência. As médias dos escores no teste (66,96) e no reteste (66,80) foram bastante semelhantes, indicando boa estabilidade das medidas ao longo do tempo. A consistência interna do instrumento, avaliada pelo alfa de Cronbach, foi de 0,885, valor elevado que sugere que os itens são coesos e mensuram consistentemente o mesmo construto. O erro padrão de medição (SEM) foi de 4,96%, indicando baixa variabilidade e elevada confiabilidade dos escores médios. A confiabilidade do instrumento também foi confirmada pela diferença mínima detectável com 90% de confiança (MDD90) entre teste e reteste, que foi de 0,02 (0,16), demonstrando variação mínima nas respostas dos participantes entre as medições e reforçando a estabilidade do instrumento.

O coeficiente de correlação intraclasse (ICC) foi de 0,794, com intervalo de confiança de 95% entre 0,73 e 0,85, confirmando boa concordância entre as medidas e indicando que o instrumento é estável quando aplicado repetidamente aos mesmos indivíduos. Em relação à validade, a maioria das correlações observadas entre a DPEBBS e os domínios do SF-36 apresentou magnitude inferior a 0,3, indicando que os construtos avaliados não são fortemente relacionados. Apenas os domínios “Limitação por Aspectos Físicos” e “Limitação por Aspectos Emocionais” apresentaram correlações negativas fracas e estatisticamente significativas, ainda assim classificadas como construtos não relacionados, de acordo com a classificação do COSMIN.

Na análise dos itens específicos do instrumento, as respostas médias apresentaram variações discretas entre o teste e o reteste, enquanto as correlações permaneceram estáveis, indicando elevada consistência e estabilidade das respostas. Em síntese, as análises estatísticas demonstraram boa consistência interna, confiabilidade e validade convergente, bem como validade divergente adequada. Esses achados reforçam a robustez do instrumento para avaliar os construtos a que se propõe.

Os dados descritivos dos participantes fornecem uma visão abrangente das características demográficas e clínicas da amostra. A idade média foi de 53,27 (±13,83) anos, com índice de massa corporal médio de 24,13 (±3,97), valores compatíveis com populações típicas de pacientes em hemodiálise, apesar das variações demográficas observadas 33,34 . A análise por sexo revelou maior prevalência de mulheres (61,6%), aspecto que deve ser considerado na generalização dos resultados para outras populações 35 . Os parâmetros bioquímicos apresentados (como hemoglobina, hematócrito, creatinina, ureia, potássio, fósforo, cálcio, sódio, ferritina e ferro) situam-se dentro dos valores esperados para pacientes em hemodiálise, refletindo a complexidade e os desafios inerentes ao manejo da DRC 36 . O número médio de hospitalizações nos últimos anos constitui um indicador relevante da carga da doença, com média de 0,31 (±0,54) internações no último ano e 2,15 (±1,93) nos últimos cinco anos, evidenciando a necessidade de intervenções contínuas para a manutenção da saúde desses pacientes 37,38 .

A análise dos escores do Short Form Health Survey 36 (SF-36) evidenciou prejuízos importantes em diversos domínios da qualidade de vida relacionada à saúde. Limitações físicas, limitações emocionais e redução da vitalidade foram particularmente expressivas, destacando o impacto multifacetado da DRC sobre o bem-estar dos pacientes 39 . Esses achados reforçam a importância de abordar não apenas barreiras físicas, mas também fatores psicossociais que podem influenciar a adesão à atividade física em pacientes em diálise.

Em comparação com o estudo original de Zheng et al., a população avaliada neste estudo apresentou diferenças que podem ter influenciado os valores de validade observados. No estudo original, a maioria dos participantes era do sexo masculino e o principal acesso dialítico era a fístula arteriovenosa, enquanto, no presente estudo, predominou o sexo feminino e o uso de cateter como principal forma de acesso à hemodiálise 22 .

No que se refere à relação entre qualidade de vida e percepção de barreiras e benefícios da atividade física, os resultados do presente estudo foram semelhantes aos de Zheng et al., sendo a baixa qualidade de vida um achado recorrente na população avaliada. Ainda assim, os participantes reconheceram os benefícios da atividade física, sugerindo que a baixa adesão a programas de exercício e reabilitação pode estar associada a outros fatores, como fadiga ou medo de lesões 9 . Os índices psicométricos observados para a DPEBBS neste estudo também são comparáveis aos relatados em investigações anteriores que utilizaram a DPEBBS e outros instrumentos de desfecho relatado pelo paciente em populações em hemodiálise 12 . No estudo de Ghafourifard et al., a DPEBBS apresentou consistência interna satisfatória e associações relevantes com desfechos autorreferidos, apoiando seu uso em pesquisas clínicas. De forma semelhante, a DPEBBS demonstrou alta consistência interna, boa confiabilidade teste-reteste e erro de medição aceitável, indicando escores estáveis e reprodutíveis ao longo do tempo. Esses índices de confiabilidade são comparáveis aos relatados para instrumentos amplamente utilizados no cuidado ao paciente em diálise, como o KDQOL-SF (Kidney Disease Quality of Life – Short Form) e o SF-36, que, embora avaliem construtos mais amplos e não específicos de exercício, apresentam consistência interna e reprodutibilidade adequadas. Assim, a DPEBBS demonstra desempenho psicométrico comparável ao de escalas consolidadas no contexto da diálise, com a vantagem adicional de captar especificamente a percepção dos pacientes sobre benefícios e barreiras relacionados ao exercício físico, um construto diretamente relevante para o planejamento e a avaliação de intervenções de atividade física em hemodiálise.

Os achados do presente estudo são amplamente consistentes com os relatados por Lightfoot et al. (2021) 14 , que investigaram percepções de benefícios e barreiras ao exercício em uma grande amostra de pacientes em hemodiálise e diálise peritoneal utilizando a DPEBBS. Em ambos os estudos, a fadiga emergiu como uma das barreiras mais frequentemente relatadas, confirmando seu papel central como fator limitante para a prática de exercícios nessa população. De forma semelhante, benefícios relacionados à melhoria da qualidade de vida, do humor e da função física foram amplamente reconhecidos pelos pacientes em ambos os contextos, sugerindo uma percepção consistente dos efeitos positivos do exercício. No entanto, diferenças na frequência de determinadas barreiras, como aquelas relacionadas às comorbidades e ao impacto do exercício na vida familiar, foram observadas entre os estudos, possivelmente refletindo variações nos perfis clínicos, nos cenários de cuidado e nos desenhos metodológicos. Apesar dessas diferenças, os padrões gerais de resposta indicam que pacientes em diálise compartilham percepções semelhantes quanto aos principais benefícios e obstáculos à prática de exercícios, reforçando a necessidade de estratégias de intervenção que abordem especificamente a fadiga e enfatizem benefícios considerados clinicamente relevantes pelos próprios pacientes.

Wingood et al. destacaram a considerável heterogeneidade na avaliação das barreiras percebidas à atividade física entre adultos com 50 anos ou mais, enfatizando a necessidade de instrumentos específicos para diferentes populações 21 . Embora 33 ferramentas distintas tenham sido identificadas na revisão, a maioria foi validada em apenas um estudo, e nenhuma foi desenvolvida especificamente para pacientes em diálise. Nesse contexto, o presente estudo preenche uma lacuna importante ao disponibilizar uma versão brasileira validada de um instrumento direcionado à população em diálise. Diferentemente de escalas genéricas, como a Exercise Benefits/Barriers Scale (EBBS), a DPEBBS aborda benefícios e barreiras diretamente relacionados ao contexto do tratamento dialítico, o que pode explicar as correlações fracas, porém teoricamente coerentes, observadas com os domínios do SF-36. Esses resultados reforçam a compreensão de que instrumentos focados em barreiras ao exercício avaliam construtos relacionados, porém distintos, da qualidade de vida geral e destacam a importância de avaliações psicométricas robustas em populações clínicas específicas, especialmente em países de baixa e média renda com elevada carga de DRC.

Pesquisas futuras devem concentrar-se na avaliação da responsividade da DPEBBS em ensaios de reabilitação em hemodiálise, particularmente em estudos voltados à promoção da atividade física e da adesão ao exercício. Investigações longitudinais também são necessárias para estabelecer pontos de corte clinicamente significativos, como escores associados à baixa participação em exercícios ou à adesão insatisfatória a programas de reabilitação. Além disso, a validação de versões alternativas da escala, incluindo formatos eletrônicos e adaptações para outros idiomas, poderá ampliar ainda mais sua aplicabilidade em diferentes contextos clínicos e culturais.

Implicações na Prática da Fisioterapia

Os achados deste estudo sugerem que a DPEBBS pode ser incorporada à prática clínica como uma ferramenta de suporte à tomada de decisão, especialmente no contexto da reabilitação de pacientes em hemodiálise. Sua aplicação permite identificar perfis de pacientes com maior percepção de barreiras à atividade física, favorecendo a estratificação de risco comportamental e a priorização de intervenções.

Adicionalmente, o instrumento pode subsidiar o desenvolvimento de estratégias individualizadas de exercício, alinhadas às necessidades e percepções dos pacientes, contribuindo para abordagens mais centradas no paciente. Nesse sentido, seu uso pode otimizar o planejamento terapêutico, especialmente em programas intradialíticos ou domiciliares, ao integrar aspectos físicos e psicossociais relacionados à adesão ao exercício.

Limitações

Este estudo apresenta limitações que devem ser consideradas na interpretação dos resultados. Primeiramente, trata-se de um estudo conduzido em um único centro, o que pode restringir a generalização dos achados para outras populações e contextos assistenciais.

Além disso, a predominância de participantes do sexo feminino pode ter influenciado os resultados, considerando possíveis diferenças na percepção de barreiras e benefícios relacionados à atividade física.

A utilização do SF-36 como medida de validade de construto, embora amplamente aceita, pode não capturar de forma específica aspectos relacionados ao exercício físico, o que pode justificar as correlações de baixa magnitude observadas.

Adicionalmente, a ausência de avaliação da responsividade limita a compreensão da capacidade do instrumento em detectar mudanças ao longo do tempo. Por fim, a não realização de análise fatorial exploratória ou confirmatória restringe a verificação da estrutura dimensional da escala na população brasileira.

Conclusão

A versão brasileira recebeu a nomenclatura “Escala de Percepção da Atividade Física em Diálise (EPAD)”.

A EPAD demonstrou adequada validade e confiabilidade para uso em pacientes em diálise, configurando-se como um instrumento robusto para a avaliação de benefícios e barreiras percebidas à prática de atividade física. Apesar de suas propriedades psicométricas satisfatórias, limitações como a realização do estudo em um único centro devem ser consideradas na interpretação dos resultados. Ainda assim, a EPAD apresenta potencial aplicabilidade clínica, podendo subsidiar o aconselhamento individualizado e o planejamento de intervenções de exercício em unidades de hemodiálise, contribuindo para estratégias mais centradas no paciente.

Material Suplementar

O seguinte material online está disponível para o presente artigo:

Versão em português brasileiro da DPEBBS (198.7KB, pdf) .

Footnotes

Financiamento: A presente publicação foi financiada parcialmente pela Coordenação de Aperfeiçoamento de Pessoal de Nível Superior – Brasil (CAPES) – Código de Financiamento 001.

Disponibilidade de Dados

Os dados que sustentam os achados deste estudo estão disponíveis com o autor correspondente, mediante solicitação razoável.

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Data Availability Statement

    The data that support the findings of this study are available from the corresponding author upon reasonable request.

    Os dados que sustentam os achados deste estudo estão disponíveis com o autor correspondente, mediante solicitação razoável.


    Articles from Jornal Brasileiro de Nefrologia are provided here courtesy of Sociedade Brasileira de Nefrologia

    RESOURCES