Correction to “Ion‐Driven Interfacial Engineering of MXene‐PAM Hydrogels for Advanced Wearable ECG and AI‐Driven Blood Pressure Monitoring”

PMCID: PMC13189481  PMID: 42170493

1.

Bangul, K., Bilawal, K., Syed, B. A., Waseem, U. K., Junchen, L., Shohidul, I., Iyapan, G., Raffi U. S. A., Mohamed E. H., Bee L. K. Ion‐Driven Interfacial Engineering of MXene‐PAM Hydrogels for Advanced Wearable ECG and AI‐Driven Blood Pressure Monitoring. Small Science. 2026; 6: e202500526. https://doi.org/10.1002/smsc.2025005264

In the originally published version of this article, a notation error appeared in the y‐axis labels of the strain‐dependent resistance change graphs. Specifically, the relative resistance change was incorrectly labeled as ΔR/R instead of the correct notation ΔR/R 0. This error occurred in the following figures: Figure 5 in the main manuscript and Supporting Figures 13, 14, and 15 in the Supporting Information. The figures have now been corrected to display the accurate notation ΔR/R 0. This correction does not affect any data, results, or conclusions presented in the article.

FIGURE 5.

FIGURE 5

Strain performance characterization of PAM, PAM–CaCl2, and ion‐driven Ti3C2T x –PAM hydrogel. (A) Relative resistance changes (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel over a strain range from 300 to 1000%. (B) Gauge factors and relative resistance changes (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel at 400 to 1000% strains. (C) Response and recovery times for the ion‐driven Ti3C2T x –PAM hydrogel at 25% strain. (D) Stability characterization through relative resistance variations (ΔR/R 0) in ions‐driven Ti3C2T x –PAM hydrogel when stretched to 100%, across 1000 consecutive cycles. (E) Stability characterization through relative resistance variations (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel when stretched to 100%, 300%, 500%, 800%, and 1000% strain across 100 consecutive cycles. (F) Conductivity measurements for hydrogel samples: S‐1 (PAM + 0.5M CaCl2 + MX 0.5%), S‐2 (PAM + 0.5M CaCl2 + MX 1%), and S‐3 (PAM + 0.5M CaCl2 + MX 1.5%). Error bars represent mean ± SD (n = 3). (G) Real‐time monitoring of relative resistance changes (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel during finger bending at various angles. (H) Real‐time monitoring of relative resistance changes (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel during elbow bending at various angles. (I) Real‐time relative resistance changes (ΔR/R 0) in ion‐driven Ti3C2T x –PAM hydrogel are monitored during wrist bending at various angles.

Supporting Figure 13.

Supporting Figure 13

Relative resistance changes (ΔR/R 0) in Ions‐driven Ti3C2Tx–PAM hydrogel over a 10–300% strain range.

Supporting Figure 14.

Supporting Figure 14

Gauge factors and relative resistance changes (ΔR/R 0) in Ions‐driven Ti3C2Tx–PAM hydrogel at 10 to 300% strains.

Supporting Figure 15.

Supporting Figure 15

Relative resistance changes (ΔR/R 0) in Ions‐driven Ti3C2Tx–PAM hydrogel over a 100% strain range at −20°C, 0°C and 40°C.

We apologize for this error.