Abstract
Estimation of postmortem interval (PMI) is a fundamental component of forensic pathology. One of the reliable methods is assessment using biochemical markers such as sodium, potassium, chloride, bicarbonate, and hypoxanthine. Among biochemical markers, vitreous potassium (K⁺) has been extensively studied due to its predictable postmortem changes and relative stability. In comparison to other body fluids, vitreous humor is resistant to early putrefaction changes and is least affected by external factors. A systematic search of PubMed and Scopus databases was conducted using predefined search strategies. Studies involving human subjects, measurement of vitreous potassium, and evaluation of its relationship with PMI were included. A total of 123 studies were identified from PubMed and Scopus; 24 studies met the inclusion criteria and were included. Vitreous potassium demonstrated a strong positive correlation with PMI (r = 0.84-0.99), with most studies supporting a linear relationship within the first 72 hours, although some reported a biphasic pattern. Significant variability in regression models was observed due to differences in environmental conditions, analytical methods, and study populations. Temperature showed inconsistent but notable effects, particularly at extended PMIs, where deviations from linearity reduced reliability. Methodological heterogeneity further influenced results, while recent evidence suggests improved accuracy when potassium is combined with additional biochemical markers such as hypoxanthine and albumin. Vitreous potassium is a reliable marker for estimating PMI, especially in early stages. However, variability limits its standalone accuracy, and integration with multiparameter models is recommended.
Keywords: pmi, postmortem interval, thanatochemistry, vitreous humor, vitreous potassium
Introduction and background
Estimation of the postmortem interval (PMI) remains one of the most challenging aspects of forensic practice. After death, bodies undergo various decomposition changes, both physical and chemical. For greater precision in estimating time of death and for scientific understanding, the electrolyte composition of biological fluids has been the main focus of research in forensic medicine. Traditional methods of calculating time since death by assessing rigor mortis, livor mortis, and algor mortis are inherently subjective and are influenced by environmental and individual factors [1-3]. Consequently, biochemical approaches have gained increasing importance in forensic thanatology [4]. Vitreous humor is considered an ideal medium for postmortem biochemical analysis due to its anatomical isolation, resistance to putrefaction, and relatively stable composition [5,6]. Among various biochemical markers, potassium has emerged as the most extensively studied parameter and is widely regarded as the most reliable single biochemical indicator for PMI estimation [7,8].
Correlation between potassium levels and PMI was initially reported by Sturner and Gantner [9] and Adelson et al. [10]. Following death, loss of cellular membrane integrity results in passive diffusion of intracellular potassium into the extracellular vitreous humor, leading to a progressive increase in concentration over time [9,11]. This phenomenon has been consistently demonstrated across multiple studies, forming the basis for regression models correlating vitreous potassium levels with PMI [12-14]. Despite its widespread application, variability in regression equations and influencing factors such as temperature, cause of death, and analytical methods have raised concerns regarding its universal applicability [15-17]. Recent advances have focused on improving accuracy through multiparameter approaches and integration with modern analytical techniques [18-20].
Review
Materials and methods
A systematic search was conducted in accordance with the PRISMA 2020 guidelines [21]. A literature search was conducted in the PubMed and Scopus databases on February 26, 2026. The search strings used for the PubMed and Scopus databases are as follows: PubMed: ("Vitreous Humor"[MeSH Terms] OR vitreous) AND potassium AND ("postmortem interval" OR "time since death") and Scopus: ("vitreous potassium" OR "vitreous humour potassium" OR "vitreous humor potassium") AND ("postmortem interval" OR "time since death" OR PMI).
A total of 123 articles were identified; 56 from Scopus and 67 from the PubMed database. After removal of duplicates and screening for inclusion and exclusion criteria, 24 studies were included in the current systematic review. Only human studies published in English were included in this review. Original research studies in which vitreous potassium concentrations were measured and the relationship between potassium and PMI was evaluated were included in this analysis. Original studies on animals, case reports, and studies without sufficient correlation or regression data were excluded.
Data Extraction
Data extracted included (1) author(s); (2) year of publication; (3) country/countries where the study was conducted; (4) study design; (5) sample size; (6) PMI range; (7) temperature considerations; (8) analytical methods; (9) regression equations/correlation coefficients; and (10) key findings. Data extraction was performed by a single reviewer using the data extraction table with the details mentioned above over a period of 15 days. The extracted data were cross-checked for accuracy by a separate reviewer.
Due to heterogeneity in study designs, analytical techniques, and environmental conditions, a quantitative meta-analysis was not conducted. The findings were therefore synthesized qualitatively. The methodological quality of the included studies was assessed using the Joanna Briggs Institute critical appraisal checklists [22], appropriate to the study designs, and is presented in the Risk of bias assessment section. The checklist items were grouped into domains of selection bias, measurement bias, and confounding for simplified interpretation, and an overall risk of bias was assigned for each study.
The study selection process is illustrated in Figure 1.
Figure 1. PRISMA flow diagram of study selection.
Relationship between vitreous potassium and PMI
All included studies demonstrated a progressive increase in vitreous potassium concentration with increasing PMI. The majority reported a linear relationship, particularly within the early postmortem period (<72 hours) [9,11]. While most studies demonstrate a linear increase in vitreous potassium with increasing PMI, some suggest a biphasic pattern, with a steeper rise in the early postmortem period followed by a slower rate of increase at later intervals [4,11,23,24]. The exact nature of this relationship remains unsettled. Reported correlation coefficients ranged from r = 0.84 to 0.99, indicating a strong association across studies. However, regression equations varied widely, with slopes ranging approximately from 1.0 to 7.1 hours per mmol/L. This wide variation reflects differences in environmental conditions, analytical techniques, and study populations. Several studies reported deviation from linearity at prolonged PMIs (>100 hours), suggesting reduced reliability of potassium-based models in late postmortem periods [17].
Effect of temperature
Temperature was identified as a major influencing factor. Zilg et al. [11] evaluated late PMIs (up to 17 days) in bodies stored in mortuary cold rooms and observed a nonlinear rise in vitreous potassium. Decedent age and ambient temperature contributed to variability by 16% and 5%, respectively. In contrast, Foster et al. [25] did not account for environmental temperature. Earlier, Sturner and Gantner [9] suggested that temperature does not significantly influence vitreous potassium levels. However, Komura and Oshiro [12] reported a decline in potassium concentration in human and rabbit eyes at low temperatures. Similarly, Rognum et al. [7] demonstrated variation in potassium elevation across four distinct environmental temperatures. These findings highlight the inconsistent influence of temperature on vitreous potassium, underscoring its role as a potential confounding factor in PMI estimation.
Methodological variability
Different analytical techniques were used across studies to measure vitreous potassium ion concentration, including flame photometry, ion-selective electrodes, and advanced biosensor methods. These variations contributed significantly to differences in reported regression equations [16]. Bortolotti et al. [26] utilized capillary ion analysis with UV detection; however, this method demonstrated limited sensitivity and required complex instrumentation. Zhou et al. [20] measured vitreous potassium using low-pressure ion chromatography but were unable to adequately account for qualitative interference from other components. Passos et al. [6] described a sequential injection system for automated detection of potassium and hypoxanthine; however, the method involved complex pretreatment steps and prolonged operational time. These methodological variations may contribute to inter-study differences and represent a potential source of measurement bias. Recent studies demonstrated improved accuracy using combined models incorporating potassium along with other biochemical markers such as hypoxanthine and albumin [18,19].
The characteristics of included studies are summarized in Table 1.
Table 1. Summary of data extracted from the studies included in the systematic review.
PMI, postmortem interval
| S. no. | Author | Year | Country | Study design | Sample size | PMI range | Temperature considered | Method | Regression equation/correlation | Main findings |
| 1 | Sturner and Gantner [9] | 1964 | USA/UK | Observational | ~91 | Up to 100 hours | Not standardized; environmental variation | Flame photometry | PMI = 7.14 × K - 39.1 (r = 0.987) | Strong linear correlation |
| 2 | Komura and Oshiro [12] | 1977 | Japan | Experimental | 90 | Not specified | Environmental temperature studied | Flame photometry | Not specified | Temperature influences K⁺ |
| 3 | Balasooriya et al. [13] | 1984 | UK | Observational | 59 | Not specified | Temperature-dependent changes | Autoanalyzer | Linear relationship | Inter-eye variability noted |
| 4 | Madea et al. [14] | 1990 | Germany | Observational | 100 | Not specified | Ambient temperature affects slope | Regression comparison | Multiple regression formulas; PMI = 5.26 × K - 30.9; slope 0.17-0.19 mmol/L/hour | Formula variability; temperature affects slope |
| 5 | Gamero Lucas et al. [15] | 1992 | Spain | Comparative | Not specified | Not specified | Temperature, age, terminal phase duration | Equation comparison | Regression demonstrated | High inter-study variability |
| 6 | Lange et al. [16] | 1994 | USA | Pooled analysis | 790 | Variable | Environmental + biological factors | Statistical modeling | Nonlinear relationship | Not strictly linear across datasets |
| 7 | Tagliaro et al. [17] | 1999 | Italy | Method + observational | 20 | 5-96 hours | Influencing factor | Capillary electrophoresis | K = 0.215 PMI + 4.755 (r = 0.904) | Reliable analytical method |
| 8 | Myo-Thaik-Oo et al. [18] | 2002 | Japan/Myanmar | Observational | 82 | 1-60 hours | Temperature considered | Blood gas analyzer | PMI = 5.26 × K - 6.01; PMI = 5.32 × K - 4.93 (r = 0.93) | Strong correlation |
| 9 | Muñoz Barús et al. [19] | 2002 | Spain | Observational | 206 | Not specified | Not specified | Regression analysis | PMI = 3.967 × K - 19.186 | Cause of death improves accuracy |
| 10 | Zhou et al. [20] | 2007 | China | Observational | 62 | 1-27 hours | Environmental influence | Ion chromatography | K = 0.1702 PMI + 5.5678 (r = 0.8692) | Linear correlation |
| 11 | Swain et al. [23] | 2015 | India | Observational | 100 | <96 hours | Stored at 4-8°C | Autoanalyzer | PMI = -11.86 + 2.88 × K | Vitreous humor better than CSF |
| 12 | Foster et al. [25] | 2016 | UK | Observational | 78 | 6-62 hours | Temperature considered | Ion-selective electrode | PMI = 6.42 × K - 40.94 | Moderate correlation |
| 13 | Bortolotti et al. [26] | 2011 | Italy/USA | Observational | 164 | 2-110 hours | Not specified | Capillary ion analysis | K = 0.1733 PMI + 2.3008 (r = 0.962) | Strong correlation |
| 14 | Jashnani et al. [27] | 2010 | India | Prospective | 120 | Not specified | No significant effect | Flame photometry | PMI = 1.076 × K - 2.815 | Differs from Western data; K⁺ rises |
| 15 | Mihailovic et al. [28] | 2012 | Serbia | Experimental | 320 samples (32 cases) | ≤30 hours | Controlled 20°C | Repeated sampling | PMI = 2.749 × K - 11.978 | Controlled conditions improve accuracy |
| 16 | Deokar and Shendarkar [29] | 2013 | India | Observational | 152 | 1.6-39.2 hours | Not specified | Biochemical analysis | Linear relationship | Strong correlation |
| 17 | Siddamsetty et al. [30] | 2014 | India | Cross-sectional | 210 | >72 hours | Climate considered | Biochemical analysis | PMI = 4.701 × K - 29.603 (r = 0.841) | Strong correlation |
| 18 | Bohra et al. [31] | 2014 | India | Observational | 200 | 0-72 hours | No significant effect | Ion-selective electrode | PMI = -16.22 + 3.75 × K | No effect of age/sex/temperature |
| 19 | Rathinam et al. [32] | 2015 | India | Cross-sectional | 55 | 0 to >24 hours | No significant effect | Ion-selective electrode | 1 mEq/L increase = 1.99 h PMI | Valid in trauma cases |
| 20 | Dhanak and Johry [33] | 2016 | India | Prospective | 200 | Early PMI | Not specified | Ion-selective autoanalyzer | 1 mEq/L increase = 2.99 h PMI | Strong early PMI relation |
| 21 | Ortmann et al. [34] | 2016 | Germany | Observational | 600 | 0-125 hours | Ambient + biological factors | Five-equation comparison | Slope 0.17-0.19 mmol/L/hour | High variability |
| 22 | Ding et al. [35] | 2017 | China | Experimental | 63 | ≤36 hours | Not specified | Fluorescence aptasensor | PMI = -0.55 + 1.66 × K (r = 0.791) | High sensitivity, not clinically validated |
| 23 | Cordeiro et al. [36] | 2019 | Portugal | Observational | 331 | Not specified | Ambient + rectal temp + weight | Indirect potentiometry | Multivariable additive models | Combined variables improve accuracy |
| 24 | Paul et al. [37] | 2021 | India | Prospective | 75 | 4 hours and 50 minutes to 36 hours and 40 minutes | Not specified | Ion-selective automated analyzer | PMI = 1.075 × K - 2.53 (r = 0.997) | Very strong correlation |
Risk of bias assessment
The risk of bias assessment demonstrated that the majority of included studies had a moderate overall risk of bias. Selection bias was generally low to moderate across studies, while measurement bias was predominantly low due to the use of standardized biochemical techniques. However, confounding factors, particularly environmental and storage temperature, were inadequately addressed in several studies, contributing to a higher risk of bias in this domain. Only a few studies employed controlled conditions or multivariable models to minimize confounding effects. Overall, five studies were categorized as low risk, while the remaining studies were predominantly of moderate risk, with no studies demonstrating a high overall risk of bias. Confounding due to temperature variation was the most frequently identified source of bias across studies. The observed heterogeneity in results, particularly related to temperature and methodological variability, is consistent with the identified confounding and measurement biases across studies.
Risk of bias assessment is summarized in Table 2.
Table 2. JBI risk of bias assessment summary.
JBI, Joanna Briggs Institute
| S. no. | Author (year) | Selection bias | Measurement bias | Confounding (temperature, methodology, etc.) | Overall risk |
| 1 | Sturner and Gantner (1964) [9] | Moderate | Moderate | High | Moderate |
| 2 | Komura and Oshiro (1977) [12] | Low | Moderate | Low | Low |
| 3 | Balasooriya et al. (1984) [13] | Moderate | Moderate | Moderate | Moderate |
| 4 | Madea et al. (1990) [14] | Low | Low | Moderate | Low |
| 5 | Gamero Lucas et al. (1992) [15] | Moderate | Moderate | Moderate | Moderate |
| 6 | Lange et al. (1994) [16] | Low | Moderate | Moderate | Moderate |
| 7 | Tagliaro et al. (1999) [17] | Moderate | Low | Moderate | Moderate |
| 8 | Myo-Thaik-Oo et al. (2002) [18] | Low | Low | Low | Low |
| 9 | Muñoz Barús et al. (2002) [19] | Low | Moderate | High | Moderate |
| 10 | Zhou et al. (2007) [20] | Moderate | Low | Moderate | Moderate |
| 11 | Swain et al. (2015) [23] | Moderate | Moderate | Low (controlled storage conditions) | Moderate |
| 12 | Foster et al. (2016) [25] | Moderate | Low | Low | Moderate |
| 13 | Bortolotti et al. (2011) [26] | Low | Low | High | Moderate |
| 14 | Jashnani et al. (2007) [27] | Low | Moderate | Moderate | Moderate |
| 15 | Mihailovic et al. (2012) [28] | Low | Low | Low | Low |
| 16 | Deokar and Shendarkar (2013) [29] | Moderate | Moderate | High | Moderate |
| 17 | Siddamsetty et al. (2014) [30] | Low | Moderate | Low | Moderate |
| 18 | Bohra et al. (2014) [31] | Moderate | Moderate | High | Moderate |
| 19 | Rathinam et al. (2015) [32] | Moderate | Moderate | High | Moderate |
| 20 | Dhanak and Johry (2016) [33] | Low | Moderate | High | Moderate |
| 21 | Ortmann et al. (2016) [34] | Low | Moderate | Moderate | Moderate |
| 22 | Ding et al. (2017) [35] | Low | Low | High | Moderate |
| 23 | Cordeiro et al. (2019) [36] | Low | Low | Low | Low |
| 24 | Paul et al. (2021) [37] | Low | Low | High | Moderate |
Discussion
The present systematic review confirms a consistent increase in potassium concentration with increasing PMI, particularly within early PMIs [9,12-14]. However, there is no consensus regarding the mathematical equation that best explains this increase. Existing models generally assume a linear increase in vitreous potassium with PMI; however, variations in slope and baseline values have been reported [11]. Thus, this limits the universal applicability of potassium as a standalone marker. Harper [38] noted that vitreous humor samples rarely contain significant numbers of bacteria or fungi, rendering them less susceptible to postmortem solute changes compared to other body fluids.
A major limitation is the significant variability in regression equations, which has been highlighted in multiple comparative and analytical studies [15-17,26-28]. Differences in study populations, environmental conditions, and analytical techniques contribute to inconsistencies in slope and intercept values, limiting the generalizability of any single predictive model.
Temperature is an important influencing factor, although its effect has been inconsistently reported across studies. Both experimental and observational studies have demonstrated that ambient and storage temperatures significantly affect the rate of potassium increase [29-31]. Cooling delays biochemical changes, whereas higher temperatures accelerate them, emphasizing the need for temperature-adjusted models. Sturner and Gantner [9] reported that temperature does not significantly influence vitreous potassium concentrations. However, this finding contrasts with the longstanding view that potassium levels are affected by ambient temperature, consistent with the general principle that biological processes are slowed at lower temperatures.
Methodological variability also plays a substantial role. Differences in analytical techniques such as flame photometry, ion-selective electrodes, and capillary electrophoresis contribute to inter-study variation [23,25,32]. Even minor variations in sample handling and calibration can influence measured potassium levels.
Another important observation is the nonlinear behavior of potassium at extended PMIs. Several studies have reported plateauing or a reduced rate of increase beyond 100 hours, limiting their reliability in late PMIs [33-35]. Ortmann et al. [34] used five different equations to assess the time since death in 600 cases where the exact time since death was known. They observed that the standard deviations between real and extrapolated time since death increase with increasing PMI or potassium concentration. Improved precision may be achieved by multiple linear regression analysis, incorporating not only the potassium concentration but also other vitreous humor electrolytes.
Biological factors such as cause of death and metabolic state may also influence potassium levels. Some studies demonstrated improved predictive accuracy when such variables were incorporated into regression models [36]. In a study by Zilg et al. [11], it was observed that the age of the deceased significantly influenced the rise in potassium concentrations, with younger individuals demonstrating a more rapid increase. The differences were observed across every age group. Most of the studies did not consider age as a factor that can cause significant changes in vitreous potassium concentration. Recent research highlights a shift toward multiparameter models, combining potassium with other biochemical markers such as hypoxanthine and albumin [3,24,37]. These approaches have shown improved accuracy and represent the future direction of PMI estimation.
Despite these limitations, vitreous potassium remains a simple, cost-effective, and widely applicable tool in forensic investigations. However, it should always be interpreted in conjunction with other findings for optimal accuracy. Limitations of the study include heterogeneity in study design and methodology, variability in temperature conditions, limited data for late PMIs, lack of standardized regression models, and potential publication bias. Language restriction (English-only studies) may have influenced the findings.
Conclusions
Vitreous potassium is a valuable biochemical marker for estimating PMI, particularly in early postmortem periods. However, variability in influencing factors limits its standalone accuracy. Future research should focus on standardization and integration of multiparameter models. The wide variation in regression slopes (approximately 1.0-7.1) across studies likely reflects differences in environmental conditions, study populations, and analytical methodologies, thereby limiting the universal applicability of vitreous potassium-based PMI estimation.
Disclosures
Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following:
Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work.
Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work.
Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Author Contributions
Concept and design: Remya Sadananda Shenoi, Ajay Balachandran, Anu Sasidharan
Acquisition, analysis, or interpretation of data: Remya Sadananda Shenoi
Drafting of the manuscript: Remya Sadananda Shenoi, Ajay Balachandran, Anu Sasidharan
Critical review of the manuscript for important intellectual content: Ajay Balachandran, Anu Sasidharan
References
- 1.Is there recent progress in the estimation of the postmortem interval by means of thanatochemistry? Madea B. Forensic Sci Int. 2005;151:139–149. doi: 10.1016/j.forsciint.2005.01.013. [DOI] [PubMed] [Google Scholar]
- 2.Time of death dependent criteria in vitreous humor—accuracy of estimating the time since death. Madea B, Rödig A. Forensic Sci Int. 2006;164:87–92. doi: 10.1016/j.forsciint.2005.12.002. [DOI] [PubMed] [Google Scholar]
- 3.The effect of cold chamber temperature on the cadaver's electrolyte changes in vitreous humor and plasma. Murthy AS, Das S, Thazhath HK, Chaudhari VA, Adole PS. J Forensic Leg Med. 2019;62:87–91. doi: 10.1016/j.jflm.2019.01.012. [DOI] [PubMed] [Google Scholar]
- 4.Vitreous potassium as a measure of the postmortem interval: an historical review and critical evaluation. Coe JI. Forensic Sci Int. 1989;42:201–213. doi: 10.1016/0379-0738(89)90087-x. [DOI] [PubMed] [Google Scholar]
- 5.Vitreous humor endogenous compounds analysis for post-mortem forensic investigation. Pigaiani N, Bertaso A, De Palo EF, Bortolotti F, Tagliaro F. Forensic Sci Int. 2020;310:110235. doi: 10.1016/j.forsciint.2020.110235. [DOI] [PubMed] [Google Scholar]
- 6.Estimation of postmortem interval by hypoxanthine and potassium evaluation in vitreous humor with a sequential injection system. Passos ML, Santos AM, Pereira AI, Santos JR, Santos AJ, Saraiva ML, Lima JL. Talanta. 2009;79:1094–1099. doi: 10.1016/j.talanta.2009.02.054. [DOI] [PubMed] [Google Scholar]
- 7.Estimation of time since death by vitreous humor hypoxanthine, potassium, and ambient temperature. Rognum TO, Holmen S, Musse MA, Dahlberg PS, Stray-Pedersen A, Saugstad OD, Opdal SH. Forensic Sci Int. 2016;262:160–165. doi: 10.1016/j.forsciint.2016.03.001. [DOI] [PubMed] [Google Scholar]
- 8.Improvement in estimation of time since death by albumin and potassium concentrations in vitreous humor. Focardi M, Lanzilao L, Bonari A, et al. Forensic Sci Int. 2020;314:110393. doi: 10.1016/j.forsciint.2020.110393. [DOI] [PubMed] [Google Scholar]
- 9.The postmortem interval. Sturner WQ, Gantner Jr GE. Am J Clin Pathol. 1964;42:137–144. doi: 10.1093/ajcp/42.2.137. [DOI] [PubMed] [Google Scholar]
- 10.Vitreous potassium concentration as an indicator of the postmortem interval. Adelson L, Sunshine I, Rushforth NB, Mankoff M. https://pubmed.ncbi.nlm.nih.gov/14070464/ J Forensic Sci. 1963;8:503–514. [PubMed] [Google Scholar]
- 11.A new model for the estimation of time of death from vitreous potassium levels corrected for age and temperature. Zilg B, Bernard S, Alkass K, Berg S, Druid H. Forensic Sci Int. 2015;254:158–166. doi: 10.1016/j.forsciint.2015.07.020. [DOI] [PubMed] [Google Scholar]
- 12.Potassium levels in the aqueous and vitreous humor after death. Komura S, Oshiro S. Tohoku J Exp Med. 1977;122:65–68. doi: 10.1620/tjem.122.65. [DOI] [PubMed] [Google Scholar]
- 13.The biochemistry of vitreous humour. A comparative study of the potassium, sodium and urate concentrations in the eyes at identifical time intervals after death. Balasooriya BA, Hill CA, Williams AR. Forensic Sci Int. 1984;26:85–91. doi: 10.1016/0379-0738(84)90064-1. [DOI] [PubMed] [Google Scholar]
- 14.Precision of estimating the time since death by vitreous potassium — comparison of two different equations. Madea B, Hermann N, Henbge C. Forensic Sci Int. 1990;46:277–284. doi: 10.1016/0379-0738(90)90313-n. [DOI] [PubMed] [Google Scholar]
- 15.Precision of estimating time of death by vitreous potassium — comparison of various equations. Gamero Lucas JJ, Romero JL, Ramos HM, Arufe MI, Vizcaya MA. Forensic Sci Int. 1992;56:137–145. doi: 10.1016/0379-0738(92)90171-r. [DOI] [PubMed] [Google Scholar]
- 16.Human postmortem interval estimation from vitreous potassium: an analysis of original data from six different studies. Lange N, Swearer S, Sturner WQ. Forensic Sci Int. 1994;66:159–174. doi: 10.1016/0379-0738(94)90341-7. [DOI] [PubMed] [Google Scholar]
- 17.Capillary zone electrophoresis of potassium in human vitreous humour: validation of a new method. Tagliaro F, Manetto G, Cittadini F, Marchetti D, Bortolotti F, Marigo M. J Chromatogr B Biomed Sci App. 1999;733:273–279. doi: 10.1016/s0378-4347(99)00338-2. [DOI] [PubMed] [Google Scholar]
- 18.No significant differences in the postmortem interval in Myanmar and Japanese using vitreous potassium levels. Myo-Thaik-Oo Myo-Thaik-Oo, Tanaka E, Oikawa H, Aita K, Tanno K, Yamazaki K. J Clin Forensic Med. 2002;9:70–73. [Google Scholar]
- 19.Improved estimation of postmortem interval based on differential behaviour of vitreous potassium and hypoxantine in death by hanging. Muñoz Barús JI, Suárez-Peñaranda JM, Otero XL, Rodríguez-Calvo MS, Costas E, Miguéns X. Forensic Sci Int. 2002;125:67–74. doi: 10.1016/s0379-0738(01)00616-8. [DOI] [PubMed] [Google Scholar]
- 20.The determination of potassium concentration in vitreous humor by low pressure ion chromatography and its application in the estimation of postmortem interval. Zhou B, Zhang L, Zhang G, Zhang X, Jiang X. J Chromatogr B Analyt Technol Biomed Life Sci. 2007;852:278–281. doi: 10.1016/j.jchromb.2007.01.027. [DOI] [PubMed] [Google Scholar]
- 21.The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Page MJ, McKenzie JE, Bossuyt PM, et al. BMJ. 2021;372:0. doi: 10.1186/s13643-021-01626-4. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.The revised JBI critical appraisal tool for the assessment of risk of bias for analytical cross-sectional studies. [ Apr; 2026 ];Barker TH, Hasanoff S, Aromataris E, et al. https://jbi.global/critical-appraisal-tools. JBI Evid Synth. 2026 24:401–408. doi: 10.11124/JBIES-24-00523. [DOI] [PubMed] [Google Scholar]
- 23.Estimation of post-mortem interval: a comparison between cerebrospinal fluid and vitreous humour chemistry. Swain R, Kumar A, Sahoo J, Lakshmy R, Gupta SK, Bhardwaj DN, Pandey RM. J Forensic Leg Med. 2015;36:144–148. doi: 10.1016/j.jflm.2015.09.017. [DOI] [PubMed] [Google Scholar]
- 24.Postmortem vitreous chemistry - an evaluation of sodium, potassium and chloride levels in estimation of time since death (during the first 36 h after death) Chandrakanth HV, Kanchan T, Balaraj BM, Virupaksha HS, Chandrashekar TN. J Forensic Leg Med. 2013;20:211–216. doi: 10.1016/j.jflm.2012.09.001. [DOI] [PubMed] [Google Scholar]
- 25.Estimation of postmortem interval using vitreous potassium levels in cases of fatal road traffic collision. Foster SN, Smith PR, Biggs M, Rutty GN, Hollingbury FE, Morley SR. Arch Med Sadowej Kryminol. 2016;66:71–82. doi: 10.5114/amsik.2016.63866. [DOI] [PubMed] [Google Scholar]
- 26.Study of vitreous potassium correlation with time since death in the postmortem range from 2 to 110 hours using capillary ion analysis. Bortolotti F, Pascali JP, Davis GG, Smith FP, Brissie RM, Tagliaro F. Med Sci Law. 2011;51:0–3. doi: 10.1258/msl.2010.010063. [DOI] [PubMed] [Google Scholar]
- 27.Vitreous humor: biochemical constituents in estimation of postmortem interval. Jashnani KD, Kale SA, Rupani AB. J Forensic Sci. 2010;55:1523–1527. doi: 10.1111/j.1556-4029.2010.01501.x. [DOI] [PubMed] [Google Scholar]
- 28.Estimation of the postmortem interval by analyzing potassium in the vitreous humor: could repetitive sampling enhance accuracy? Mihailovic Z, Atanasijevic T, Popovic V, Milosevic MB, Sperhake JP. Am J Forensic Med Pathol. 2012;33:400–403. doi: 10.1097/PAF.0b013e31826627d0. [DOI] [PubMed] [Google Scholar]
- 29.Estimation of post mortem interval by means of changes in the eye-vitreous humour potassium levels. Deokar R, Shendarkar A. Indian J Forensic Med Toxicol. 2013;7:232. [Google Scholar]
- 30.Estimation of time since death from electrolyte, glucose and calcium analysis of postmortem vitreous humour in semi-arid climate. Siddamsetty AK, Verma SK, Kohli A, Puri D, Singh A. Med Sci Law. 2014;54:158–166. doi: 10.1177/0025802413506424. [DOI] [PubMed] [Google Scholar]
- 31.Estimation of postmortem interval by measuring potassium level in vitreous humour. Bohra B, Verma R, Mathur IB, Sharma Y, Khangwal VP, Joshi M. J Indian Forensic Sci. 2014;36:374–378. [Google Scholar]
- 32.Vitreous potassium concentration as a predictor of postmortem interval in injury (trauma) cases: a cross-sectional study from a tertiary care center in rural Haryana. Rathinam RD, Goel S, Chhoker V, Chikkara P, Singh A, Goel S, Singh NK. https://journals.lww.com/mjdy/fulltext/2015/08030/vitreous_potassium_concentration_as_a_predictor_of.8.aspx Med J Dr Patil Univ. 2015;8:315–318. [Google Scholar]
- 33.A study on the vitreous potassium ion concentration in relation with time since death. Dhanak KL, Johry A. Indian J Forensic Med Toxicol. 2016;10:250–256. [Google Scholar]
- 34.Precision of estimating the time since death by vitreous potassium—comparison of 5 different equations. Ortmann J, Markwerth P, Madea B. Forensic Sci Int. 2016;269:1–7. doi: 10.1016/j.forsciint.2016.10.005. [DOI] [PubMed] [Google Scholar]
- 35.Estimation of postmortem interval by vitreous potassium evaluation with a novel fluorescence aptasensor. Ding Y, Li X, Guo Y, et al. Sci Rep. 2017;7:1868. doi: 10.1038/s41598-017-02027-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.A reliable method for estimating the postmortem interval from the biochemistry of the vitreous humor, temperature and body weight. Cordeiro C, Ordóñez-Mayán L, Lendoiro E, Febrero-Bande M, Vieira DN, Muñoz-Barús JI. Forensic Sci Int. 2019;295:157–168. doi: 10.1016/j.forsciint.2018.12.007. [DOI] [PubMed] [Google Scholar]
- 37.Estimation of post-mortem interval from vitreous potassium: an autopsy based study. Paul PM, Sneha S, Pradhan P, Kumar PS. J Indian Acad Forensic Med. 2021;43:370–373. [Google Scholar]
- 38.A comparative study of the microbiological contamination of postmortem blood and vitreous humour samples taken for ethanol determination. Harper DR. Forensic Sci Int. 1989;43:37–44. doi: 10.1016/0379-0738(89)90120-5. [DOI] [PubMed] [Google Scholar]

