Abstract
Background:
Obtaining optimum cleanliness of root canal walls through mechanical and chemical tools has not yet been attained, mostly in the apical third of the root canal, and it has become more difficult in curved canals. This work aimed to investigate the impact of maintaining apical patency on the cleaning potentials of XP-endo Finisher in the apical third of curved root canals.
Materials and Methods:
Thirty curved roots (25o:30o) were assigned for the study, divided into two groups: patency maintained (PM) and patency not maintained (PN). Irrigation activation performed using XP-endo finisher. Samples were longitudinally sectioned, and apical 1, 3, and 5 mm smear layer scores were assessed using a scanning electron microscope at ×2000. The smear layer scores from 1:4 were recorded as ordinal data.
Statistical Analysis:
Data were represented as median and interquartile range. Intergroup comparisons were performed using the Mann–Whitney U-test. Intragroup comparisons were analyzed using the Kruskal–Wallis test.
Results:
Apical patency improved the cleaning potentials of XP-endo Finisher at apical 1 and 3 mm without statistical significance, while at 5 mm, it showed a statistical significance (P < 0.5). Apical 1 mm showed the least smear layer removal abilities, while 5 mm showed the best.
Conclusion:
XP-endo Finisher irrigation activation proved high cleanliness abilities in curved root canals, which improved when canal patency was maintained during the treatment. One millimeter apical segment has reported the lowest cleanliness regardless of whether canals patency was maintained or not.
Keywords: Apical patency, curved root canals, scanning electron microscope, smear layer, XP-endo Finisher
INTRODUCTION
The goal of disinfection of the root canal system has been carried through chemomechanical preparation of root canals utilizing variable irrigants and instruments.[1] Constant efforts have been implemented to secure an armamentarium that guarantees optimum disinfection of the root canal system.[2] Displeasing sequel of dentin wall instrumentation is smearing and debris loading on the root canal walls, which limits the action of irrigants and the obturation material–dentin wall adherence (tight seal).[3] Another tooth-related factor that might restrict effective cleaning of the root canal is anatomical complexities including variations in numbers, size, cross-section, and curvature.[4] About 84% of root canals have been reported with curvature, which sheds light on how they can be properly managed.[5] Difficulties in the management of curved root canals are not only limited to difficulties in working length determination, patency achievement, and instrument fatigue, but also include the proper cleaning of the root canal walls compared to straight root canals.[6,7] Researchers reported low cleaning ability of different manual and rotary files at the apical one-third of the root canal, which is the part of the root canal reported to have variable anatomical complexities, especially in curved roots.[8,9] Apical patency has been introduced by Buchanan and approved by the American Association of Endodontics as a possible approach that would maintain the root canal apical portion debris-free.[10] Poor cleaning of the apical root third has been reported and attributed to complex anatomy, existing tissues, and entrapped gas bubbles that impede proper cleaning at the apical third.[5] Apical patency has reported less debris accumulation with passive ultrasonic irrigation compared to nonpatent canals, and patent canals showed a lower percentage of gas bubbles than nonpatent canals (25% and 40%, respectively).[11] XP-endo Finisher is a MaxWire-made innovative finishing file by (FKG Dentaire, La Chaux-de-Fonds, Switzerland); a zero-taper, # 25 file has the ability to transform by working at body temperature with subsequent contractions and expansions, which offers irrigation agitation and canal wall scraping.[12,13] It has proved cleaning efficiency on debris accumulated in root canals isthmus and reduction of bacterial load in oval-shaped root canals.[14,15] Debris on root canal walls investigation gave a clue about how effective is the cleaning and shaping and spotlighted the necessity to evolve materials, instruments, and techniques to facilitate this mission along with preservation of the tooth integrity.[16] The influence of apical patency during primary endodontic treatment of curved root canals on cleaning ability of XP-endo Finisher has not been investigated yet. This work aimed to investigate the impact of maintaining apical patency on the root canal wall cleaning potentials of XP-endo Finisher in the apical third of curved root canals.
MATERIALS AND METHODS
The study protocol was submitted and approved by the institution’s ethics committee (TUCDREC/161125/RAbdelgawad). The size of the sample was determined using G*Power software version 3.1.9.6 (Heinrich-Heine-Universitat Düsseldorf, Düsseldorf, Germany), derived the data from similar studies with an effect size of 0.57, α =0.05, β =0.05, and test power = 0.95.[17,18] Thirty mandibular premolars were assigned for this study, 15 for each group. Teeth were selected from fresh-extracted human teeth for periodontal, prosthetic, or orthodontic reasons. Teeth with incomplete root formation, cracks, resorptive defects, or previous endodontic treatment were excluded. Radiographic imaging of the teeth was performed to confirm Vertucci type I root canals, and images were used to determine the angle of root curvature following Schneider’s method.[19,20] Teeth with curvature angle range 25o:30o were selected, and pairs of teeth with the same angle of curvature were allocated randomly in the study groups: group patency maintained (PM) and patency not maintained (PN), and then, all were stored for a week in 2% thymol solution at room temperature.[5] The sample length was adjusted to 17 mm by reducing the crown occlusal surface with a diamond disc (Henry Schein, Inc., Melville, NY, USA). Access cavities were adjusted using #3081 diamond burs (KG Sorensen, São Paulo, Brazil), K-file size#10 was inserted to adjust the working length measurement, and root canals where K-file size #15 did not fit at working length were excluded and replaced.[5] With the aim of mimicking the clinical environment, root apices were sealed using a layer of pink wax, and samples were coated with a separating medium and put up in acrylic resin blocks using a 1.5 mm × 1.5 mm × 2 mm rubber mold (Shofu Inc., Kyoto, Japan), and apical curvature was kept oriented in the same direction during mechanical preparation.[21] Root canals were instrumented using Mtwo files to size 30, 4% following manufacturer instructions (VDW GmbH, Munich, Germany).[22] Apical patency was maintained only in the PM group using K-file size #10, succeeding each rotary file 0.5 mm longer than working length. Root canal irrigation consumed a total of 2 ml of 3% sodium hypochlorite (NaOCl) (Formula and Action, São Paulo, Brazil) per canal following each file use. During agitation and final rinse, NaOCl irrigant was placed in 37oC water bath to maintain its warmth; 2 ml was dispensed 1 mm shorter of working length using a passively inserted 30G needle (Ultradent Products Inc., South Jordan, Utah, USA).[23] XP-endo Finisher used in gentle vertical strokes with 7–8 mm in–out motion for 1 min at a speed of 1000 and 1.0 Ncm, then debris final flash-out using 2 ml of saline solution.[12] Samples were displaced passively from resin blocks, under microscopic ×10 (Carl Zeiss Meditec, Oberkochen, Germany); two shallow opposite longitudinal grooves at labial and lingual surfaces were carefully made using a diamond disk (Jota, Ruthi, Switzerland) without penetrating root canals, and then, halves were separated carefully with a chisel and mallet and carefully examined to pick out the one that distinctly displayed the apical third.[24] Photomicrographs of the apical third at 1, 3, and 5 mm from the apical foramen were supplied at ×2000 using a scanning electron microscope (SEM) (Quanta FEG-250, the Netherlands). Two experienced endodontists assessed 30 randomly selected micrographs for calibration of interoperator agreement, and micrographs assessment performed following Rome et al.’s four-scale scoring: 1 – clean root canal wall and all dentinal tubules open, 2 – minimal amount of smear layer, >50% of the dentinal tubules open; 3 – moderate amount of smear layer, <50% of dentinal tubules open; and 4 – heavy smear layer with complete obliteration of dentinal tubules.[25] Ninety photomicrographs were examined blindly without identifying either the group or the segment examined, and the data were subjected to statistical analysis.
Statistical analysis
Interoperator agreement was assessed using Cohen’s kappa test (Minitab 18.1, Minitab, Inc., Pennsylvania State University, PA, United States). The smear layer scores (1:4) were recorded as ordinal data for each segment: 1 mm, 3 mm, and 5 mm. Data were represented as median and interquartile range. Intergroup comparisons at each segment were performed using the Mann–Whitney U-test. Intragroup comparisons among the three segments were analyzed using the Kruskal–Wallis test. The Chi-square test was used to compare clean (score 1 + 2) or not clean (score 3 + 4) records in study groups at each segment investigated as well as to compare the three segments within each group. Statistical significance was set at P < 0.05. Data were analyzed with IBM SPSS Statistics (Armonk, New York, USA), version 25 for Windows.
RESULTS
Interoperator record agreement was reported with a 0.92 kappa value. Table 1 and Figure 1 demonstrate a comparison of recorded smear layer removal scores in the PM group and the PN group in three investigated segments (1, 3, and 5 mm). Data showed a statistically nonsignificant difference among the PM and PN groups in both 1 mm and 3 mm segments (P = 0.539, 0.116), respectively, while in 5 mm, the PM group reported significantly higher median values (P = 0.016). Intragroup comparison revealed statistically no significant difference between median values in 1 mm, 3 mm, and 5 mm sections in the PM and PN groups (P = 0.036, 0.917), respectively.
Table 1.
Inter- and intragroup comparison of median score values and interquartile range
| Segments | PM group, median (IQR) | PN group, median (IQR) | P |
|---|---|---|---|
| 1 mm | 2 (3–2) | 3 (3–2) | 0.539 (NS) |
| 3 mm | 2 (2–2) | 2 (3–2) | 0.116 (NS) |
| 5 mm | 2 (2–2) | 2 (3–2) | 0.016* |
| P | 0.036 (NSG) | 0.917 (NSG) |
*Statistically significant difference between data at P≤0.05 using the Mann–Whitney U-test. NS: Nonstatistically significant difference between data at P>0.05 using the Mann–Whitney U-test, NSG: Nonstatistically significant difference between data at P>0.05 using the Kruskal–Wallis test. IQR: Interquartile range, PM: Patency maintained, PN: Patency not maintained, NS: Nonsignificant, NSG: Nonsignificantly greater
Figure 1.

Photomicrographs for apical third segments (1, 3, and 5 mm) of the experimental groups, with patency maintained and patency not maintained. PM: Patency maintained, PN: Patency not maintained
Table 2 demonstrates the distribution of frequency and percentage of clean (score 1 + 2) and not clean (scores 3 + 4) in both the groups’ assessed segments (1, 3, and 5 mm). The highest clean scores (93.33) were recorded in 5 mm segment of the PM group, and the lowest clean scores (46.67%) were reported in 1 mm segments of the PN group, while the highest not clean scores (53.33%) were recorded in 1 mm segments of the PN group and the lowest (6.67%) in 5 mm segments of the PM group. Both the PM and PN groups showed no significance between frequency and percentage of clean and not clean scores in 1 and 3 mm segments (P = 0.464, 0.121), respectively, while there was a significant difference between clean and not clean scores in 5 mm segment of both the groups (P = 0.13).
Table 2.
Frequency and percentage of the clean (score 1+2) and not clean (score 3+4) in patency maintained and patency not maintained groups at 1, 3, and 5 mm segments
| Segments | PM group | PN group | P | ||
|---|---|---|---|---|---|
|
|
|
||||
| Clean, frequency (%) | Not clean, frequency (%) | Clean, frequency (%) | Not clean, frequency (%) | ||
| 1 mm | 9 (60) | 6 (40) | 7 (46.67) | 8 (53.33) | 0.464 (NS) |
| 3 mm | 12 (80) | 3 (20) | 8 (53.33) | 7 (46.67) | 0.121 (NS) |
| 5 mm | 14 (93.33) | 1 (6.67) | 8 (53.33) | 7 (46.67) | 0.013* |
*Statistically significant difference between data at P≤0.05 using the Chi-square test. NS: Nonstatistically significant difference between data at P>0.05 using the Chi-square test. PM: Patency maintained, PN: Patency not maintained, NS: Nonsignificant
DISCUSSION
The standard of mechanical and chemical debridement of the root canal grants the success of root canal treatment.[26] Debridement tools and techniques can be assessed through investigating their potentials to clear dentin walls from debris and smear layer.[21] Lasting debris and smear layer are physical and biological obstacles able to interdict disinfection and seal of the root canal system.[27] Limitations of optimum cleanliness achievement of apical third canal wall using chemical, mechanical tools, and techniques, which have been reported effective at middle and coronal root thirds, were inferred to structural, physical, and anatomical properties of apical dentin.[8,9] These considerations are aggravated more in curved roots, where curvature might impede free instrument movement and irrigation circulation.[28]
Although endodontic files are the tool of root canal mechanical debridement, they are incompetent of thorough wall debridement, and their work on dentin wall creates a smear layer that consequently must be removed.[18] Hence, the role of irrigation in the elimination of debris and disinfection of the root canal system is boosted, and one of the modalities to intensify irrigation efficacy is to establish intraradicular irrigation activation to assist the access of irrigation through the entire root canal system.[29] Although passive ultrasonic activation, self adjusting file activation, and other irrigation activation tools have proven effective dentin debridement, limited capacity has been reported at root apical third, necessitating further efforts to secure an optimum debridement tool of root canal system.[27]
The XP-endo Finisher has been fabricated to provide safe and effective irrigation activation. It has been manufactured from a unique nickel–titanium alloy (Max-Wire) that, once subjected to temperature change in root canals (high temperature), transformed from martensite to austenite phase, enabling the file to transform from straight to curved (anatomic) with enhanced adaptation to canal walls.[12] XP-endo Finisher reported more intraradicular bacterial load reduction and biofilm elimination than passive ultrasonic activation, but none were able to manage the canals’ isthmus. It showed comparable intracanal medicament removal ability with passive ultrasonic activation, self-adjusting file, and canal brush at the cervical root third, but none were able to provide entirely clean walls.[14,15] Moreover, it showed similar smear layer removing potentials to EndoVac in curved canals and to passive ultrasonic activation with limited efficiency for all to establish debris-free apical third.[28]
The concept of root canal patency has been proven to have a favorable impact on the mechanical and biological objectives of the treatment procedure.[11] Apical patency enhanced the extent of irrigation solution toward the working length in adjuncts with ultrasonic activation of NaOCl.[29] Patency file proved a significant ability to burst bubbles in the coronal and middle thirds, enabling access to the apical third.[11] Other studies by Tay et al. and Gu et al. demonstrated that the existence of gas bubbles entrapped in the apical third of the root is able to restrict the flow of the irrigation.[30,31] In spite of the studied impact of apical patency on root canal treatment procedures, starting with facilitating the glide path and working length determination accuracy to proven long-term treatment success, there is no available data that investigate its impact on cleaning potentials in curved root canals that received primary root canal treatment. Considering the reported inability of chemical and mechanical cleaning approaches in the root canal apical third optimum cleaning, this study was concerned with the assessment of the apical third’s wider surface area and gave more details about three segments of the apical third.
Debris-free dentin walls and patent dentinal tubules observation with SEM root surface magnification is a reliable methodology; however, magnification gave a feedback of a small surface area.[26] In this study, the apical third was divided into three segments to allow more surface area assessment. On the other hand, various qualitative scoring methods of smear layer are well-documented methods for gauging.[26] In this methodology, root canal wall micrographs at ×2000 were assessed following Rome et al.’s four-scale scoring.[25] The sample inclusion criteria (tooth type, length, curvature, and initial size), preparation (instrument size and type), and irrigation protocol (materials, volume, duration, and sequence) were congruent to eliminate their probable influence on the results.[32] XP-endo Finisher displayed high cleaning standards, whether patency was maintained or not, 64% of apical third segments were recorded as clean, 36% was not clean, and none of the segments displayed heavy debris with obliterated dentinal tubules (score 4). The cleaning potentials of XP-endo Finisher were attributed to the file transfigure from straight to spoon-like upon structure phase transformation when working in warmer root canals, and this allows better activation of irrigation, touches, and effectively debrides canal walls.[12,13]
Maintained apical patency recorded a positive impact on XP-endo Finisher cleaning potentials; 38.9% of apical segments reported clean canal walls in the PM group versus 25.6% of the PN group. This was explained due to the patency file’s ability to burst the entrapped gas bubble and open the access for irrigation to untouched canal walls.[31] Although the positive impact of maintained apical patency through root canal treatment on the cleaning potentials of XP-endo Finisher irrigation activation, the intended root canal wall cleanliness has not been achieved yet.
Proximity to apical foramen at 1 and 3 mm segments displayed less clean walls than 5 mm segment, where XP-endo Finisher cleaning potentials were the highest. This zone-related limited cleanliness ability was on account of morphological, anatomical, and structural characteristics of the canal wall, which reported constraints against the achievement of optimum three-dimensional cleanliness.[11] This study revealed the imperative necessity of continuous work to come up with suitable tools, materials, and maneuvers to achieve the optimum three-dimensional root canal cleanliness.
CONCLUSION
XP-endo Finisher irrigation activation proved high cleanliness abilities in curved root canals, which improved when canal patency was maintained during the treatment. 1 mm apical segment has reported the lowest cleanliness, regardless of whether canals patency was maintained or not.
Clinical relevance
Root canals’ morphology is considered a major obstacle for achieving effective cleaning and consequently impacts the success of root canal treatment. Continual work to provide techniques, materials, and instruments to achieve this goal is crucial. Apical patency proved a positive impact on the effectiveness of cleaning and shaping procedures; this research investigated its influence on XP-endo Finisher cleaning potentials in the apical third of curved root canals.
Conflicts of interest
There are no conflicts of interest.
Funding Statement
Nil.
REFERENCES
- 1.Hemalatha S, Srinivasan A, Srirekha A, Santhosh L, Champa C, Shetty A. An in vitro radiological evaluation of irrigant penetration in the root canals using three different irrigation systems: Waterpik WP-100 device, passive irrigation, and manual dynamic irrigation systems. J Conserv Dent. 2022;25:403–8. doi: 10.4103/jcd.jcd_162_22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Tomson PL, Adams N, Kavanagh D, Virdee SS. Non-surgical endodontics: Contemporary biomechanical preparation of the root canal system. Br Dent J. 2025;238:478–86. doi: 10.1038/s41415-025-8599-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Azimian S, Bakhtiar H, Azimi S, Esnaashari E. In vitro effect of XP-endo finisher on the amount of residual debris and smear layer on the root canal walls. Dent Res J (Isfahan) 2019;16:179–84. [PMC free article] [PubMed] [Google Scholar]
- 4.Afreen L, Chandra R, Jain J, Mehrotra A. Comparative evaluation of removal of smear layer using newer rotary endodontic files: A scanning electron microscope study. J Conserv Dent. 2021;24:616–21. doi: 10.4103/jcd.jcd_92_21. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Wigler R, Srour Y, Wilchfort Y, Metzger Z, Kfir A. Debris and smear layer removal in curved root canals: A comparative study of ultrasonic and sonic irrigant activation techniques. Dent J (Basel) 2024;12:51. doi: 10.3390/dj12030051. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Khurana P, Nainan MT, Sodhi KK, Padda BK. Change of working length in curved molar root canals after preparation with different rotary nickel-titanium instruments. J Conserv Dent. 2011;14:264–8. doi: 10.4103/0972-0707.85809. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Zhou N, Huang Z, Yu M, Deng S, Fu B, Jin H. Influence of needle working length and root canal curvature on irrigation: A computational fluid dynamics analysis based on a real tooth. BMC Oral Health. 2022;22:179. doi: 10.1186/s12903-022-02205-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Pereira ES, Peixoto IF, Nakagawa RK, Buono VT, Bahia MG. Cleaning the apical third of curved canals after different irrigation protocols. Braz Dent J. 2012;23:351–6. doi: 10.1590/s0103-64402012000400007. [DOI] [PubMed] [Google Scholar]
- 9.Timponi Goes Cruz A, Antoniw Klemz A, Ribeiro Rosa EA, Soares Grecca F, Mattos B, Piasecki L, et al. Cleaning and disinfection of the root canal system provided by four active supplementary irrigation methods. Sci Rep. 2024;14:3795. doi: 10.1038/s41598-024-53375-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.American Association of Endodontists. Glossary of Endodontic Terms. 7th ed. Chicago: American Association of Endodontists; 2003. [Google Scholar]
- 11.Vera J, Arias A, Romero M. Dynamic movement of intracanal gas bubbles during cleaning and shaping procedures: The effect of maintaining apical patency on their presence in the middle and cervical thirds of human root canals-an in vivo study. J Endod. 2012;38:200–3. doi: 10.1016/j.joen.2011.10.026. [DOI] [PubMed] [Google Scholar]
- 12.FKG Dentaire SA. The XP-endo Finisher File Brochure. [[Last accessed on 2026 Apr 14]]. Available from: https://fkg.ch/finisher/
- 13.Trope M, Debelian G. XP-3D Finisher™files the next step in restorative endodontics. Endod Pract US. 2015;8:22–4. [Google Scholar]
- 14.Poly A, Marques F, Lee J, Setzer FC, Karabucak B. XP-endo Finisher effectively reduces hard-tissue debris accumulated in root canals with isthmus after preparation with a reciprocating file system. Aust Endod J. 2023;49:279–86. doi: 10.1111/aej.12676. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Carvalho MC, Zuolo ML, Arruda-Vasconcelos R, Marinho AC, Louzada LM, Francisco PA, et al. Effectiveness of XP-Endo Finisher in the reduction of bacterial load in oval-shaped root canals. Braz Oral Res. 2019;33:e021. doi: 10.1590/1807-3107bor-2019.vol33.0021. [DOI] [PubMed] [Google Scholar]
- 16.Iandolo A, Pisano M, Abdellatif D, Sangiovanni G, Pantaleo G, Martina S, et al. Smear layer and debris removal from root canals comparing traditional syringe irrigation and 3D cleaning: An ex vivo study. J Clin Med. 2023;12:492. doi: 10.3390/jcm12020492. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Kapasi K, Kesharani P, Kansara P, Patil D, Kansara T, Sheth S. In vitro comparative evaluation of efficiency of XP-endo shaper, XP-endo finisher, and XP-endo finisher-R files in terms of residual root filling material, preservation of root dentin, and time during retreatment procedures in oval canals – A cone-beam computed tomography analysis. J Conserv Dent. 2020;23:145–51. doi: 10.4103/JCD.JCD_257_20. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Abdelgawad RA, Hussein SA. Evaluation of cinnamon zylanicum (true cinnamon) versus ethylenediaminetetraacetic acid smear layer removal ability: A scanning electron microscope study. J Conserv Dent Endod. 2025;28:426–30. doi: 10.4103/JCDE.JCDE_94_25. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Akçay A, Gorduysus M, Gorduysus MO, Annamma LM, Müftüoglu S. A comparative evaluation of the cleaning efficacy of five different root canal irrigation devices: A histological study. Eur J Dent. 2024;18:827–33. doi: 10.1055/s-0043-1774325. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol. 1971;32:271–5. doi: 10.1016/0030-4220(71)90230-1. [DOI] [PubMed] [Google Scholar]
- 21.Robberecht L, Dehurtevent M, Lemaitre G, Béhal H, Hornez JC, Claisse-Crinquette A. Influence of root canal curvature on wall cleanliness in the apical third during canal preparation. Eur Endod J. 2017;2:1–6. doi: 10.14744/eej.2017.16035. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Azar MR, Safi L, Nikaein A. Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth. Dent Res J (Isfahan) 2012;9:146–51. doi: 10.4103/1735-3327.95227. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Arora R, Gupta T, Mirdha N, Gill B. Comparative evaluation of efficacy of different irrigation devices in removal of calcium hydroxide in teeth with simulated internal resorption cavities –An in vitro study. J Conserv Dent. 2022;25:625–9. doi: 10.4103/jcd.jcd_271_22. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.De-Deus G, Belladonna FG, Zuolo AS, Cavalcante DM, Carvalhal JC, Simões-Carvalho M, et al. XP-endo Finisher R instrument optimizes the removal of root filling remnants in oval-shaped canals. Int Endod J. 2019;52:899–907. doi: 10.1111/iej.13077. [DOI] [PubMed] [Google Scholar]
- 25.Rome WJ, Doran JE, Walker WA., 3rd The effectiveness of Gly-Oxide and sodium hypochlorite in preventing smear layer formation. J Endod. 1985;11:281–8. doi: 10.1016/S0099-2399(85)80158-8. [DOI] [PubMed] [Google Scholar]
- 26.Orstavik D, Pitt Ford TR. Essential Endodontology: Prevention and Treat¬ment of Apical Periodontitis. 2nd ed. Oxford, UK: Ames, Iowa, England: Blackwell Munksgaard; 2008. [Google Scholar]
- 27.Bakthavatchalam B, Ranjani MS, Amudhalakshmi K, Dhanalakshmi S. Comparative evaluation of canal cleanliness at apical third using Self-adjusting file and wave one file with different irrigants: An in vitro scanning electron microscopic study. Med Pharm Rep. 2023;96:79–85. doi: 10.15386/mpr-2238. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Hassan R, Elzahar S. Cleaning efficiency of XP finisher, XP finisher R and passive ultrasonic irrigation following retreatment of teeth obturated with totalfill hiflow bioceramic sealer. Eur Endod J. 2022;7:143–9. doi: 10.14744/eej.2022.39358. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Kuzhanchinathan M, Dhakshinamurthi B, Rajendran MR, Kalaiselvam R. Influence of apical patency in endodontic treatment outcome –A systematic review of clinical studies. J Conserv Dent Endod. 2024;27:1091–7. doi: 10.4103/JCDE.JCDE_584_24. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Tay FR, Gu LS, Schoeffel GJ, Wimmer C, Susin L, Zhang K, et al. Effect of vapor lock on root canal debridement by using a side-vented needle for positive-pressure irrigant delivery. J Endod. 2010;36:745–50. doi: 10.1016/j.joen.2009.11.022. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Gu LS, Kim JR, Ling J, Choi KK, Pashley DH, Tay FR. Review of contemporary irrigant agitation techniques and devices. J Endod. 2009;35:791–804. doi: 10.1016/j.joen.2009.03.010. [DOI] [PubMed] [Google Scholar]
- 32.Nagy E, Kotaki N, Dudás M, Gryschka DG, Braunitzer G, Antal MA. Comparative analysis of nickel–titanium instrumentation systems for root canal anatomy preservation: An in vitro study. Appl Sci. 2025;15:429. [Google Scholar]
