Abstract
Background
This study aimed to evaluate the safety of anterior chamber air tamponade post-phacoemulsification on the cornea compared to balanced salt solution or Ringer’s lactate filling, and summarize its potential influence on the aspects like the risk of postoperative endophthalmitis and Descemet’s membrane detachment (DMD).
Methods
This meta-analysis was conducted using Review Manager 5.4 and included studies that evaluated post-phacoemulsification air tamponade compared with no air tamponade before October 2025. Methodological quality was assessed using the Cochrane Risk of Bias tool. This review was registered in PROSPERO (CRD420251177446) and followed PRISMA guidelines.
Results
Among seven included studies (1340 eyes), there were no significant between-group differences (mean difference [95% confidence interval]) at 1 month, with or without air tamponade, in the endothelial cell density (−103.59 [−256.86 to 49.68] cells/mm2; p = 0.19), central corneal thickness (−4.86 [−19.81 to 10.08] µm; p = 0.52), or coefficient of variation of the corneal endothelial cell size (−0.01 [−0.04 to 0.01]; p = 0.22). A minimal yet significant difference in hexagonality favored the no-air-tamponade group (−0.01 [−0.03 to −0.00]; p = 0.03).
Conclusions:
Intracameral air injection demonstrated comparable short-term corneal endothelial safety, with the potential added benefits of reduced inflammation and infection risk and of protection of the Descemet’s membrane.
Trial registration
PROSPERO, CRD420251177446. Registered 2025.
Clinical trial number
Not applicable.
Keywords: Anterior chamber air tamponade, Cataract, Corneal endothelium, Phacoemulsification
Background
Cataract is the primary cause of reversible vision loss [1], with approximately 95 million people affected worldwide [2]. Considering its general good outcome in visual rehabilitation with a low complication rate, phacoemulsification has become the gold standard for cataract extraction in most countries [1, 2]. After the phacoemulsification, the clear corneal incision should be well-sealed while maintaining the depth of anterior chamber (AC) [3–7]. This enables the maintenance of physiological intraocular pressure (IOP), prevents the inflow of ocular surface fluid into the AC, and stabilizes the intraocular lens (IOL) position [8–11]. Air tamponade has been proposed as a technique with acceptable safety that may offer certain advantages over conventional BSS/Ringer’s lactate reformation for sealing clear corneal incisions, but its potential benefits and risks remain incompletely defined. For example, air tamponade has been suggested to mitigate phacoemulsification-induced DMD [12, 13], and to potentially reduce endophthalmitis risk through physical barrier effects [14]. However, these putative benefits need to be validated by a larger sample of research; furthermore, concerns exist regarding potential endothelial effects.
Air tamponade has the most prominent effect on the corneas, whereas phacoemulsification has proven deleterious to the corneal endothelium [15–17]. This endothelium comprises a single layer of endothelial cells situated between AC and corneal stroma and forms a barrier against the aqueous humor [18, 19]. It is essential for maintaining corneal stromal hydration at approximately 78% and corneal transparency that functions as a bicarbonate “pump” [20–22]. The corneal endothelium has limited regenerative ability; therefore, decreased density or function that exceeds its critical threshold can cause permanent endothelial functional decompensation [23, 24]. During cataract surgery, the energy of phacoemulsification, mechanical trauma, increased IOP, and AC surging could all injure the corneal endothelium, and thereby decrease the endothelial cell count and impair cell structure and function. Patients may experience corneal edema and even irreversible bullous keratopathy, which necessitates corneal tissue transplantation [25–28].
Under these circumstances, air injection may help restore normal IOP and AC, isolating the corneal endothelial layer from the water and thus protecting the corneal endothelium from surgical events. However, direct contact between sterilized air and the corneal endothelium is unnatural, and it is unclear whether such contact confers any potential detrimental effects. Additionally, current literature on this issue presents contradictory findings. Therefore, we performed a systematic review to comprehensively evaluate effects of anterior chamber air tamponade post-phacoemulsification on corneal endothelial parameters, IOL positional stability, and risks of postoperative endophthalmitis and DMD. Furthermore, by performing a meta-analysis of available clinical studies, we sought to clarify whether air tamponade following phacoemulsification confers superior corneal endothelium protection.
Methods
Eligibility criteria
All studies that compared effects on the cornea with air injection without air injection into the AC at the end of phacoemulsification were included. The group receiving intracameral air injection for anterior chamber reformation at the conclusion of phacoemulsification was defined as the intervention group; the group receiving balanced salt solution (BSS) or Ringer’s lactate injection was defined as the control. The review was prospectively registered with the International Prospective Register of Systematic Reviews (PROSPERO 2025; registration number: CRD420251177446).
The inclusion criteria were as follows: clinical studies, including randomized controlled trials (RCTs) and retrospective studies, and comparative studies, that compared air tamponade with irrigation fluid injected into the AC at the conclusion of phacoemulsification. There were no restrictions regarding age, sex, or disease status. No language restrictions were imposed. Studies that were available only in abstract form, review articles, case reports, and single-arm observational studies that lacked a control group were excluded.
Study selection
This systematic review and meta-analysis were conducted in compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Two independent reviewers were responsible for screening the titles and abstracts of the retrieved records. For studies that were deemed relevant, full-text articles were retrieved and then assessed for eligibility according to the predefined inclusion criteria.
Search methods for identifying studies
Electronic databases, including PubMed, Web of Science, Embase, Scopus, Cochrane Library, and China National Knowledge Infrastructure, were searched by the author. The final search was performed on October 27, 2025. The thesaurus headings, search operators, and restrictions were adjusted for each database. The search terminologies included “Air,” “Air Injection,” “Air tamponade,” “Air bubble,” “Cataract Surgery,” and “Phacoemulsification.”
Data collection and risk of bias assessment
Relevant data were extracted from included studies by two independent reviewers using a standardized electronic form. Any discrepancies were addressed through discussion with a third reviewer. The category of collected information included study characteristics, participant demographics, surgical details, intervention protocols, and outcomes of interest.
The quality and risk of bias of the included articles were assessed by at least two independent reviewers. The risk of bias in RCTs was identified using the Cochrane Risk of Bias, Version 2 (RoB-2) tool; the Risk of Bias in Non-randomized Studies of Interventions (ROBINS-I) tool was used to evaluate non-RCTs. All the included studies were classified as having a low, unclear, or high risk of bias.
Data synthesis and analysis
Outcomes reported in at least two studies were included in the meta-analysis. The mean difference (MD) was applied for evaluating continuous variables between the intervention and control groups. Review Manager 5.4 was used for the data analysis. Both fixed- and random-effect models were used. The results are presented as forest plots with 95% confidence intervals. Cochran’s Q test (chi-square) was used to evaluate heterogeneity and the I2 statistic was used to measure inconsistency.
Results
Studies included in the meta-analysis
An overview of the study-selection process is presented in the PRISMA flow diagram in Fig. 1. In total, 1067 results were identified, and 342 articles underwent title/abstract screening after deduplication. Next, 23 articles underwent a full-text review. Finally, seven articles were included in the meta-analysis.
Fig. 1.
PRISMA flow diagram illustrating the study selection process for the systematic review and meta-analysis comparing air tamponade and stromal hydration in cataract surgery. PRISMA, Preferred Reporting Items for systematic Reviews and meta-Analyses
Study characteristics of studies included in the meta-analysis
The articles included in this meta-analysis were predominantly prospective (n = 4), retrospective (n = 2), and case–control studies (n = 1) [29–35]. These studies encompassed diverse populations from multiple regions and countries, including China, Egypt, Greece, Turkey, Iraq, and Taiwan, which indicated that their conclusions have broad applicability.
Patient characteristics of studies included in the meta-analysis
The seven studies collectively comprised 1340 eyes, with the patient age ranging from 50 to 85 years. Although the preoperative endothelial cell density (ECD), central corneal thickness (CCT), coefficient of variation (CV), and hexagonality (HEX) values varied slightly across the studies, they were well-balanced between the groups (Table 1).
Table 1.
Comparison of patient demographics and preoperative and operative information in the included studies
| Study source | Group | Sample size (eyes) |
Age (Years) |
Incision size (mm) |
Sex (Female) |
Cataract hardness | Phacoemulsification energy (J) |
Preoperative ECD (cells/mm2) |
Preoperative CCT (μm) |
Preoperative CV (%) |
Preoperative HEX (%) |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Keles 2022 [33] | Air Bubble Group | 71 | 65.90 ± 11.05 | 2.75 | 25 | Grade 2 | Not Provided | 2427.01 ± 31.95 | 526.08 ± 31.69 | 40.46 ± 5.12 | 44.92 ± 6.80 |
| No Air Bubble Group | 63 | 65.02 ± 10.38 | 2.75 | 20 | Grade 2 | Not Provided | 2453.24 ± 278.52 | 532.54 ± 35.29 | 40.94 ± 7.38 | 44.32 ± 5.98 | |
| Alsmman 2018 [29] | Air Group | 250 | 57.90 ± 3.90 | 2.75 | 150 | Grade 2 | 6.51 ± 1.0 | 2604 ± 367 | 509 ± 34 | 40.30 ± 8.40 | 51.00 ± 10.00 |
| BSS Group | 250 | 56.00 ± 2.30 | 2.75 | 130 | Grade 2 | 7.19 ± 1.1 | 2646 ± 284 | 508 ± 22 | 38.20 ± 6.00 | 49.00 ± 8.00 | |
| Zaki 2021 [31] | Air Group | 38 | 62.18 ± 10.51 | Not Provided | 10 | Grade 1–2 | 23.5 ± 7.3 | 2652.2 ± 371.2 | 494.26 ± 31.69 | 38.04 ± 6.5 | 55.50 ± 10.07 |
| Ringer’s Lactate Group | 38 | 65.05 ± 5.72 | Not Provided | 12 | Grade 1–2 | 25.2 ± 9.1 | 2557.8 ± 454.7 | 510.68 ± 36.39 | 35.7 ± 5.2 | 54.10 ± 13.40 | |
| Chen 2022 [32] | IABT Group | 201 | 67.90 ± 11.96 | 2.65 | 118 | Not Provided | 25.36 ± 21.02 | 2537 ± 430 | 549.80 ± 35.20 | 33.85 ± 10.73 | 64.18 ± 10.07 |
| Non-IABT Group | 233 | 69.12 ± 11.20 | 2.65 | 117 | Not Provided | 25.41 ± 20.72 | 2583 ± 391 | 554.60 ± 34.90 | 33.42 ± 11.41 | 64.67 ± 8.74 | |
| Yuksel 2019 [34] | Air Bubble Injection Group | 20 | Not Provided | 2.8 | (Total: 18/10) | Grade 3 | 7.6 ± 3.4 | 2091.0 ± 80.9 | Not Provided | Not Provided | Not Provided |
| Without Air Bubble Injection Group | 20 | Not Provided | 2.8 | (Total: 18/10) | Grade 3 | 7.9 ± 3.8 | 2096.5 ± 90.9 | Not Provided | Not Provided | Not Provided | |
| Matafisi 2020 [30] | Air bubble Group | 49 | 72 (66, 76) | 2.4 | 27 | Not Provided | 8.17 (5.03–13.7) | 2428.41 ± 355.01 | 535.94 ± 29.84 | Not Provided | Not Provided |
| Hydration Group | 49 | 71 (64, 78) | 2.4 | 20 | Not Provided | 7.57 (4.99–13.42) | 2505.24 ± 436.81 | 536.63 ± 34.87 | Not Provided | Not Provided | |
| Huang 2015 [35] | Gas Injection Group | 31 | 69.94 ± 1.68 | 3 | 14 | Exclude grade IV and V cataracts | Not Provided | 2435.71 ± 194.80 | Not Provided | Not Provided | Not Provided |
| Fluid Injection Group | 27 | 70.52 ± 1.60 | 3 | 15 | Exclude grade IV and V cataracts | Not Provided | 2430.74 ± 191.95 | Not Provided | Not Provided | Not Provided |
IABT: intracameral air bubble tamponade; BSS: balanced salt solution; ECD: Corneal endothelial cell density; CCT: Central corneal thickness; CV: Coefficient of variation; HEX: Hexagonal cell percentage
ECD at 1 month postoperatively
Five studies [29–33] that reported the ECD at 1 month postoperatively were included in the analysis. The random-effects model analysis showed that the ECD in the AC air injection group was lower than that in the control group (95% confidence interval [CI]: −256.86 to 49.68; Fig. 2A). The 95% CI for this pooled effect size was 0 (p = 0.19), which indicated no significant between-group difference in postoperative corneal ECD.
Fig. 2.
Forest plots comparing corneal endothelial parameters between the air tamponade and stromal hydration groups at 1 month postoperatively. (A) ECD. (B) CCT. (C) HEX. (D) CV. CCT, central corneal thickness; CV, coefficient of variation; ECD, endothelial cell density; HEX, percentage of hexagonal cells
However, testing revealed high heterogeneity among the included studies (I2 = 83%; p = 0.0001). There were contradictions among the results of several studies. The study by Mataftsi et al. [30] showed a significant reduction in ECD in the air-injection group (MD = −506.00), whereas other studies [29, 32, 33] reported no significant between-group differences. Notably, the reduction in ECD in the air-injection group in Mataftsi et al.’s [30] study was observed only in patients operated on by one particular surgeon, which implicated the surgical method as a key confounding factor. These contradictory results were the primary reasons for the high heterogeneity that was observed.
CCT at 1 month postoperatively
In total, four studies [29, 31–33] that reported postoperative CCT findings were included in the analysis. The random-effects model meta-analysis showed that the pooled MD of CCT in the AC of the air-injection group compared to the control group was −4.86 μm (95% CI: −19.81 to 10.08 μm; Fig. 2B). The 95% CI for this pooled effect size was zero (p = 0.52), which indicated no significant between-group difference in the postoperative corneal thickness. Heterogeneity testing revealed high heterogeneity among the included studies (I2 = 88%; Tau2 = 199.69, p < 0.0001). The results of the individual studies showed prominent inconsistency and even the opposite conclusions: Alsmman et al. [29] showed a significantly thicker CCT in the air-filled group (MD = 12.00 μm), whereas the results of the other three studies [31–33] all indicated a thicker CCT in the control group, with significant between-group differences [31, 32]. These contradictory results were the primary reasons for the high heterogeneity that was observed.
CV at 1 month postoperatively
In total, four studies [29, 31–33] that reported the CV at 1 month postoperatively were included in the analysis. The random-effects model meta-analysis showed that the pooled mean difference in the CV of the AC air-injection group compared to the control group was −0.01 (95% CI: −0.04 to 0.01; Fig. 2C). The 95% CI for this pooled effect size was zero (p = 0.22), indicating no significant between-group difference in the homogeneity of corneal endothelial cell morphology.
Heterogeneity testing revealed substantial heterogeneity among the included studies (I2 = 73%; Tau2 = 0.00; p = 0.01). This finding suggests considerable variation in the results across different studies. Specifically, Alsmman et al. [29] showed that air filling significantly reduced the CV value (MD = −0.04), whereas the results from Zaki and Mohammad [31], Keles and Karaman [33], and Chen et al. [32] showed no significant between-group differences. The inconsistency between studies contributed to the heterogeneity that was observed.
HEX at 1 month postoperatively
In total, four studies [29, 31–33] that reported HEX levels at 1 month postoperatively were included in the analysis. The fixed-effect model meta-analysis showed that the pooled mean difference in the HEX after AC air-injection group compared to the control group was −0.01 (95% CI: −0.03 to −0.00; Fig. 2D). The 95% CI for this pooled effect size did not include zero (p = 0.03), indicating that the AC Ringer’s solution or BSS filling was statistically superior to AC air filling in promoting the maintenance of regular hexagonal morphology in corneal endothelial cells, and this difference was statistically significant. However, the absolute value of the pooled effect size (−0.01) was small, and its clinical significance should be carefully evaluated in the specific context.
Heterogeneity analysis revealed no heterogeneity among the included studies (I2 = 0%, p = 0.44). This indicated that the results for the HEX metric were highly consistent across studies, indicating a trend of slightly poorer cellular regularity in the air-filled group. Among the four studies, the two with the greatest weight [29, 33] showed a trend toward lower HEX values in the air-filled group, which jointly resulted in the final pooled results.
Sensitivity analysis
The robustness of the pooled results was assessed by a leave-one-out sensitivity analysis. For the ECD at 1 month postoperatively, the robustness of the pooled results was generally inadequate. After excluding the study by Mataftsi [30], the heterogeneity among the studies was completely resolved (I2 decreased from 83% to 9%), and the pooled results remained statistically non-significant. This indicates that the current conclusion of “no statistical significance” is relatively reliable. The detailed results are shown in Fig. 3A.
Fig. 3.
Leave-one-out sensitivity analysis for the primary outcomes. (A) ECD. (B) CCT. (C) CV. CCT, central corneal thickness; CV, coefficient of variation; ECD, endothelial cell density
For the CCT at 1 month postoperatively, the results indicated that the pooled effect size and heterogeneity were highly unstable. Specifically, after excluding the study by Alsmman et al. [29], the direction of the pooled effect size changed, and heterogeneity decreased substantially (with I2 significantly dropping from 87% to 0%), as shown in the results (MD = −10.76, 95% CI: −17.89 to −3.63). These findings suggest that AC air injection potentially exerts a positive effect on reducing corneal edema during the early postoperative period. Thus, the conclusion of “no significant difference” is highly sensitive to this particular study, and indicates poor robustness of the results, which should be interpreted with caution (Fig. 3B).
For CV at 1 month postoperatively, the robustness of the results was generally high (I2 = 73%). After excluding the study by Alsmman et al. [29], the heterogeneity was resolved (I2 decreased to 38%), and the pooled result remained statistically non-significant. This indicates that the current conclusion of “no statistical significance” is relatively reliable (Fig. 3C).
In summary, the findings of this meta-analysis of the three key outcomes were not robust, thus highlighting the need for more high-quality and methodologically consistent studies to provide clearer evidence.
Risk of bias and quality assessments for the meta-analysis
The ROB-2 tools, which were used to assess the risk of bias in randomized studies, indicated a moderate risk of bias in the included studies, and suggested that the reliability of the randomized studies was moderate. However, the ROBINS-I tool used for non-randomized study evaluation showed a potentially high risk of bias among the included studies, particularly regarding participant selection and confounding factors. Therefore, the results of the present meta-analysis should be interpreted with caution. The risk of bias in the included studies is presented in Figs. 4A and 4B.
Fig. 4.
Assessment of the risk of bias in the randomized and non-randomized controlled trials using the RoB-2 tool (A) and ROBINS-I tool (B) correspondingly. ROBINS-I, risk of bias in non-randomized studies of Interventions; RoB-2, Cochrane risk of bias, Version 2
Summary of adverse events in included studies
Other adverse events and safety outcomes in our included studies such as IOP spikes, anterior chamber reformation, and patient-reported visual symptoms are detailed in Table 2. The air tamponade groups did not show any clinically significant sustained elevation compared to the control groups, nor was there a need to initiate intraocular pressure-lowering treatment owing to air tamponade according to Chen et al. [32] and Huang et al. [35]. Huang et al. [35] reported two cases of patients’ visual symptoms because of bubble migration to vitreous and posterior chamber, but these symptoms were temporary and disappeared as the bubbles were absorbed, without causing long-term effects.
Table 2.
Reporting of adverse events in included studies
| Study source | Pupillary Block | IOP Spikes | Need for IOP-Lowering Therapy | Urgent Air Release | Anterior Chamber Reformation Issues | Patient-Reported Visual Symptoms |
|---|---|---|---|---|---|---|
| Keles 2023 [33] | N | N | N | N | N | N |
| Alsmman 2018 [29] | N | N | N | N | N | N |
| Zaki 2021 [31] | N | N | N | N | N | N |
| Chen 2022 [32] | N | During Follow-up period (3 days, 10 days, 1 month, and 3 months), similar to control group | N | N | N | N |
| Yuksel 2019 [34] | N | N | N | N | N | N |
| Mataftsi 2020 [30] | N | N | N | N | N | N |
| Huang 2015 [35] | N | no significant difference on postoperative day 1 compared to preoperative values | N | N | Air group had 94% success in single-operation stabilization (vs. 33% in control) | One case of bubble migration to vitreous causing visual shadow; one case of bubble in posterior chamber; all resolved with positioning |
N: Not reported
Discussion
This systematic review and meta-analysis evaluated the effects of AC air tamponade after the completion of phacoemulsification surgery. The primary conclusion of this study was that both the techniques demonstrated comparable short-term corneal endothelial safety. The meta-analysis revealed no significant between-group differences regarding ECD, CCT, and CV 1 month postoperatively. While the pooled analysis showed a statistically significant 1% reduction in hexagonality favoring the no-air group (−0.01 [−0.03 to −0.00]; p = 0.03), the clinical significance of this minimal difference remains questionable.
Notably, leave-one-out analysis demonstrated that the exclusion of Mataftsi et al. [30] completely resolved heterogeneity for endothelial cell density (I2 decreased from 83% to 9%), suggesting that the ‘no significant difference’ conclusion is highly dependent on study inclusion criteria and individual study characteristics. Significant heterogeneity was observed in the CCT and CV outcomes, primarily stemming from the divergent results reported by Alsmman et al. [29]. The discrepancies in this study might be attributed to the relatively lower phacoemulsification energy, and thus reduced the overall surgical trauma compared to other studies. Sensitivity analysis confirmed that the pooled results for CCT were unstable, underscoring existing heterogeneity. This heterogeneity may have originated from variations in air injection protocols, differences in surgical techniques, diverse patient baseline characteristics, and potential inconsistencies in the corneal endothelial specular microscopy measurement methods across the included studies.
The included studies primarily focused on corneal biometric parameters and lacked a comprehensive assessment of complications such as transient IOP elevation or pupillary block. The incomplete reporting of clinically important safety outcomes represents a significant evidence gap and limited our meta-analysis. Pupillary block is a recognized risk of anterior chamber air, as documented in cataract surgery [36]. Flowers et al. described a case of pupillary block and angle-closure glaucoma following anterior chamber air injection in a nanophthalmic eye [36]. In a commentary, Shugar reported two similar cases in non-nanophthalmic eyes among 1123 consecutive cataract surgeries, noting that excessive bubble size was the common denominator and that prompt decompression by “burping” the incision effectively relieved the attack [36]. Future studies are needed to incorporate prespecified safety endpoints including pupillary block and IOP curves postoperatively.
According to some researches, AC injections seem to offer additional benefits other than endothelial safety (Table 3). Keles and Karaman [33] found a lower CCT in the air-injection group on the first postoperative day (indicating less edema). Thus, this may help prevent DMD, as Ti et al. [42] confirmed that preexisting endothelial pathology and corneal edema on the first postoperative day are independent risk factors for DMD. Chen et al. [32] indicated that this technique significantly shortened surgical time and reduced the incidence of persistent postoperative corneal edema. Demirci et al. [38] found that the bubble lowers aqueous nitric oxide levels and reduces AC inflammation in rabbit eyes. Mehdizadeh et al. [14] further showed that the bubble significantly decreases the incidence of Staphylococcus epidermidis-induced endophthalmitis. However, these potential benefits of reduced postoperative inflammation and endophthalmitis come from animal experiments and lack clear clinical trials to verify them, and thus, this is only a speculation. In the future, large-scale clinical trials are needed to validate this speculation. Yuksel et al. [34] confirmed that air injection markedly lessens early postoperative complications such as DMD, endothelial wound gape, and epithelial wound gape.
Table 3.
Potential effects other than corneal endothelial safety reported in literature
| First Author & Year | Study Type | Subjects | Research Focus/Direction | Total Sample Size | Main Conclusion |
|---|---|---|---|---|---|
| Sim 2007 [37] | Case Series | Human | To evaluate if an anterior chamber air bubble can prevent inflow of ocular surface fluid through sutureless cataract wounds. | 14 eyes | Injecting a small air bubble at the end of surgery effectively prevented the inflow of ocular surface fluid through the clear corneal incision, both spontaneously and upon manipulation. |
| Demirci 2013 [38] | Experimental study | Rabbit | To investigate the effect of an intracameral air bubble on postoperative inflammation using clinical grading and nitric oxide levels. | 30 eyes (15 rabbits) | Air bubble significantly reduces post-cataract inflammation. |
| Mehdizadeh 2009 [14] | Experimental study | Rabbit | To assess the ability of an anterior chamber air bubble to prevent the development of experimental bacterial endophthalmitis. |
24 eyes (24 rabbits) |
Air bubble reduces the incidence of S. epidermidis endophthalmitis. |
| Werner 2015 [39] | Laboratory case series | Human | To describe and analyze the phenomenon of localized calcification on hydrophilic acrylic IOLs following surgeries involving intracameral air/gas injection (e.g., DSEK/DSAEK). | 7 cases (7 IOLs) | Intracameral air/gas can cause localized calcification on the anterior surface of hydrophilic IOLs, impairing vision. |
| Zhou 2025 [40] | Retrospective Cohort Study | Human | To investigate the impact of anterior chamber air injection (ACAI) on IOL stability (decentration, tilt, position) after combined cataract and vitrectomy surgery with gas/air tamponade. |
51 eyes (51 patients) |
ACAI did not cause significant IOL decentration or tilt but led to a significant anterior axial shift of the IOL and prolonged the stabilization time of aqueous depth. |
| Leisser 2019 [41] | Randomized controlled monocenter study | Human | To examine whether air tamponade induces more postoperative IOL tilt or decentration compared to balanced salt solution in phacovitrectomy. | 34 eyes (from 42 initial) | Air tamponade does not induce significantly more IOL tilt or decentration compared to balanced salt solution. |
Concerns have been raised regarding the potential adverse effects of AC air injections. Although Zhou et al. [40] indicated that AC air injection during phacovitrectomy does not exacerbate IOL tilt or decentration, it has been established that air injection affects the axial position of the IOL and causes an anterior shift. This phenomenon is particularly evident in specific patient groups, such as males and those with a greater preoperative aqueous width. Moreover, Werner et al. [39] indicated a risk of localized calcification and reduced visual acuity associated with hydrophilic acrylic IOLs following AC air injection, suggesting that such IOLs should be avoided when employing this technique (Table 3).
While our meta-analysis suggests comparable endothelial safety, we caution that this interpretation is constrained by significant heterogeneity (I2 > 70% for multiple outcomes) and the predominance of short-term follow-up data. The absence of statistically significant differences should not be interpreted as proof of equivalence but should rather be interpreted as uncertainty requiring further investigation. Furthermore, this meta-analysis has a few limitations, including the limited number of included studies, primary focus on short-term follow-up at 1 month postoperatively, absence of hard nuclear cataracts in the included studies, and primary focus on corneal biometric parameters without a comprehensive assessment of other potential complications such as transient IOP elevation or visual disturbances. Future research should prioritize large-scale, methodologically uniform, and RCTs with longer follow-up durations. These studies must standardize the air injection protocol and broaden the outcome measures to include patient-reported visual quality, intraocular lens position, postoperative inflammatory response, IOP fluctuations, and incidence of rare but serious complications such as endophthalmitis. This approach could enable a more comprehensive assessment of the risks and benefits of routine AC air injection during cataract surgery.
Conclusions
This study demonstrates that, at 1-month postoperatively, intracameral air injection exhibits comparable efficacy to BSS in terms of ECD, CCT, and CV. Although a statistically significant reduction in HEX was observed in the air group (approximately 1%), its clinical relevance remains limited. It should be noted that substantial heterogeneity was present in some outcomes, and sensitivity analyses indicated instability in the pooled estimates for parameters such as CCT, warranting cautious interpretation. The included literature lacks systematic reporting of critical safety outcomes, particularly pupillary block and IOP-related events, which are essential for assessing the net clinical benefit of this technique. While theoretical advantages of air tamponade may exist, they have not been robustly demonstrated in clinical comparative studies. Well-designed randomized controlled trials with standardized protocols, longer follow-up, and comprehensive safety assessment are urgently needed to guide clinical practice.
Acknowledgements
Not applicable.
Abbreviations
- BSS
Balanced salt solution
- CCT
Central corneal thickness
- RoB-2
Cochrane Risk of Bias, Version 2
- CV
Coefficient of variation
- DMD
Descemet’s membrane detachment
- ECD
Endothelial cell density
- AC
Anterior chamber
- HEX
Hexagonality
- IOL
Intraocular lens
- IOP
intraocular pressure
- MD
Mean difference
- PRISMA
Preferred Reporting Items for Systematic Reviews and Meta-Analyses
- RCTs
Randomized controlled trials
- ROBINS-I
Risk of Bias in Non-randomized Studies of Interventions
Authors’ contributions
XBG: Conceptualization, Data curation, Formal analysis, Writing – original draft. QL: Data curation, Formal analysis, Methodology. FRL: Investigation, Validation. LJ: Investigation, Resources. LY: Supervision, Writing – review & editing. JYZ: Conceptualization, Project administration, Supervision, Writing – review & editing, Funding acquisition.
Funding
This study was supported by the National Natural Science Foundation of China [82201191] and Natural Science Foundation of Hubei Province [2023AFB461].
Data availability
All data generated or analyzed during this study are included in this published article.
Declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Contributor Information
Lei Yang, Email: shitouyang@126.com.
Jingyi Zhu, Email: dr.zhujingyi@qq.com.
References
- 1.Lam D, Rao SK, Ratra V, Liu Y, Mitchell P, King J, et al. Cataract. Nat Rev Dis Primers. 2015;1(1):15014. . 10.1038/nrdp.2015.14 [DOI] [PubMed] [Google Scholar]
- 2.Hu S, Wey S, Yano RA, Kelly LD. Fear of cataract surgery and vision loss: the effects of health literacy and patient comprehension at an academic hospital-based eye clinic. OPTH. 2025;19:1103–10. 10.2147/OPTH.S490630. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Linebarger EJ, Hardten DR, Shah GK, Lindstrom RL. Phacoemulsification and modern cataract surgery. Surv Ophthalmol. 1999;44(2):123–47. 10.1016/S0039-6257(99)00085-5. [DOI] [PubMed] [Google Scholar]
- 4.Mamalis N. Phacoemulsification technology update. J Cataract Refractive Surg. 2016;42(5):651–52. 10.1016/j.jcrs.2016.05.001. [DOI] [PubMed] [Google Scholar]
- 5.Wan H, Tao Y, Duan J, Wang L, Tang L. Association between the site of clear corneal phakic intraocular lens implantation incisions and the inflow of ocular surface fluid into the anterior chamber. Front Med. 2023;10:1063003. 10.3389/fmed.2023.1063003. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Potvin R, Matossian C, Makari S. Cataract surgery and methods of wound closure: a review. OPTH. 2015;9:921–28. 10.2147/OPTH.S83552. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Fine IH. Clear corneal incisions. Int Ophthalmol Clin. 1994;34(2):59–72. 10.1097/00004397-199403420-00005. [DOI] [PubMed] [Google Scholar]
- 8.Borkenstein AF, Packard R, Dhubhghaill SN, Lockington D, Donnenfeld ED, Borkenstein EM. Clear corneal incision, an important step in modern cataract surgery: a review. Eye (Lond). 2023;37(14):2864–76. 10.1038/s41433-023-02440-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Dewey S, Beiko G, Braga-Mele R, Nixon DR, Raviv T, Rosenthal K, et al. Microincisions in cataract surgery. J Cataract Refractive Surg. 2014;40(9):1549–57. . 10.1016/j.jcrs.2014.07.006 [DOI] [PubMed] [Google Scholar]
- 10.Sarossy A, Chakrabarti R. Physiological intraocular pressure in cataract surgery: a comparative consecutive case series study. OPTH. 2025;19:2289–94. . 10.2147/OPTH.S532483 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Grzybowski A, Kanclerz P. Early postoperative intraocular pressure elevation following cataract surgery. Curr Opin Ophthalmol. 2019;30(1):56–62. 10.1097/ICU.0000000000000545. [DOI] [PubMed] [Google Scholar]
- 12.Samarawickrama C, Beltz J, Chan E. Descemet’s membrane detachments post cataract surgery: a management paradigm. Int J Ophthalmol. 2016;9(12):1839–42. 10.18240/ijo.2016.12.23. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Gab-Alla AA. A comparative study between air bubble tamponade alone versus air bubble tamponade with internal fluid aspiration for nonplanar descemet’s membrane detachment after phacoemulsification. J Ophthalmol. 2021;2021:1–7. 10.1155/2021/9953418. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Mehdizadeh M, Rahat F, Khalili MR, Ahmadi F. Effect of anterior chamber air bubble on prevention of experimental Staphylococcus epidermidis endophthalmitis. Graefes Arch Clin Exp Ophthalmol. 2010;248(2):277–81. 10.1007/s00417-009-1173-8. [DOI] [PubMed] [Google Scholar]
- 15.Buschschlüter S, von Eicken J, Wilhelm U, Wilhelm F, Werschnik C, Schlüter R, et al. [The relationship between the temperature increase caused by phacoemulsification and the damage to the corneal endothelium]. Klin Monbl Augenheilkd. 2014;231(8):822–29. 10.1055/s-0034-1382848. [DOI] [PubMed] [Google Scholar]
- 16.Takahashi H. Corneal endothelium and phacoemulsification. Cornea. 2016;35(Supplement 1):S3–7. 10.1097/ICO.0000000000000990. [DOI] [PubMed] [Google Scholar]
- 17.Cornetta P, De Bernardo M, Rosa N. Central corneal thickness and endothelial damage after cataract surgery. Cornea. 2018;37(7):e36. 10.1097/ICO.0000000000001601. [DOI] [PubMed] [Google Scholar]
- 18.Tuft SJ, Coster DJ. The corneal endothelium. Eye (Lond). 1990;4(3):389–424. 10.1038/eye.1990.53. [DOI] [PubMed] [Google Scholar]
- 19.Joyce NC. Proliferative capacity of the corneal endothelium. Prog Retin Eye Res. 2003;22(3):359–89. 10.1016/S1350-9462(02)00065-4. [DOI] [PubMed] [Google Scholar]
- 20.Bourne WM. Biology of the corneal endothelium in health and disease. Eye (Lond). 2003;17(8):912–18. 10.1038/sj.eye.6700559. [DOI] [PubMed] [Google Scholar]
- 21.Bourne WM. Corneal endothelium—past, present, and future. Eye Contact Lens: Sciamp; Clin Pract. 2010;36(5):310–14. 10.1097/ICL.0b013e3181ee1450. [DOI] [PubMed] [Google Scholar]
- 22.Bonanno JA. Molecular mechanisms underlying the corneal endothelial pump. Exp Eye Res. 2012;95(1):2–7. 10.1016/j.exer.2011.06.004. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Okumura N, Koizumi N. Regeneration of the corneal endothelium. Curr Eye Res. 2020;45(3):303–12. 10.1080/02713683.2019.1700529. [DOI] [PubMed] [Google Scholar]
- 24.Kumar A, Yun H, Funderburgh ML, Du Y. Regenerative therapy for the cornea. Prog Retin Eye Res. 2022;87:101011. 10.1016/j.preteyeres.2021.101011. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Kosrirukvongs P, Slade SG, Berkeley RG. Corneal endothelial changes after divide and conquer versus chip and flip phacoemulsification. J Cataract Refractive Surg. 1997;23(7):1006–12. 10.1016/S0886-3350(97)80072-7. [DOI] [PubMed] [Google Scholar]
- 26.Kohnen T. Compromised corneal endothelium and cataract: how should we decide? J Cataract Refractive Surg. 2011;37(8):1377–78. 10.1016/j.jcrs.2011.06.013. [DOI] [PubMed] [Google Scholar]
- 27.Price MO, Mehta JS, Jurkunas UV, Price FW Jr. Corneal endothelial dysfunction: evolving understanding and treatment options. Prog Retin Eye Res. 2021;82:100904. 10.1016/j.preteyeres.2020.100904. [DOI] [PubMed] [Google Scholar]
- 28.Yang Y, Chai H, Ding Z, Tang C, Liang Y, Li Y, et al. Meta-analysis of corneal endothelial changes after phacoemulsification in diabetic and non-diabetic patients. BMC Ophthalmol. 2023;23(1):174. 10.1186/s12886-023-02924-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Alsmman AH, Ezzeldawla M, Mounir A, Elhawary AM, Mohammed OA, Farouk M, et al. Effect of reformation of the anterior chamber by air or by a balanced salt solution (BSS) on corneal endothelium after phacoemulsification: a comparative study. J Ophthalmol. 2018;2018:1–5. 10.1155/2018/6390706. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Mataftsi A, Dermenoudi M, Matsou A, Tzamalis A, Brazitikos P, Talimtzi P, et al. Safety of air tamponade versus corneal hydration for sealing clear corneal incisions in cataract surgery. Graefes Arch Clin Exp Ophthalmol. 2020;258(4):815–20. 10.1007/s00417-020-04602-1. [DOI] [PubMed] [Google Scholar]
- 31.Zaki ZA, Mohammad NK. Effect of reformation of the anterior chamber by air or by Ringer’s lactate solution on corneal endothelial count and morphology after phacoemulsification. MJBU. 2021;39(1):37–46. 10.33762/mjbu.2021.129641.1067. [Google Scholar]
- 32.Chen YT, Chen KJ, Yeh LK, Tan HY, Hsiao CH, Wu WC, et al. Intracameral air bubble tamponade in routine cataract surgery. Research Square.
- 33.Keles A. Corneal effect of air bubble after phacoemulsification. Beyoglu Eye J. 2022;7:261–66. 10.14744/bej.2022.65902. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Yuksel E, Cubuk MO, Ceylanoglu KS. Intracameral air injection after completion of phacoemulsification cataract surgery: evaluation of corneal incisions with optical coherence tomography. J Educ Chang Curr Ophthalmol. 2019;31(2):142–49. 10.1016/j.joco.2019.01.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Huang YZ, Sun T, Zhi YT, Li L, Yan LN. Safety observation of applying anterior chamber gas injection for unstable anterior chamber at the end of cataract surgery. Int J Ophthalmol. 2015;15:1927–29. [Google Scholar]
- 36.Flowers CW Jr. Pupillary block, angle-closure glaucoma produced by an anterior chamber air bubble in a nanophthalmic eye. Arch Ophthalmol. 1996;114(9):1145–46. 10.1001/archopht.1996.01100140347021. [DOI] [PubMed] [Google Scholar]
- 37.Sim DA, Wong R, Griffiths MF. Injecting an air bubble at the end of sutureless cataract surgery to prevent inflow of ocular surface fluid. Eye (Lond). 2007;21(11):1444–45. 10.1038/sj.eye.6702974. [DOI] [PubMed] [Google Scholar]
- 38.Demirci G, Karabas L, Maral H, Ozdek S, Gülkilik G. Effect of air bubble on inflammation after cataract surgery in rabbit eyes. Indian J Ophthalmol. 2013;61(7):343–48. 10.4103/0301-4738.109528. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Werner L, Wilbanks G, Nieuwendaal CP, Dhital A, Waite A, Schmidinger G, et al. Localized opacification of hydrophilic acrylic intraocular lenses after procedures using intracameral injection of air or gas. J Cataract Refractive Surg. 2015;41(1):199–207. 10.1016/j.jcrs.2014.10.025. [DOI] [PubMed] [Google Scholar]
- 40.Zhou Z, Sun B, Wu X, Liu Y, Guo B, Yang C, et al. Effect of anterior chamber air injection on intraocular lens stability after phacovitrectomy with gas/air tamponade. Retina. 2025;45(5):854–62. 10.1097/IAE.0000000000004382. [DOI] [PubMed] [Google Scholar]
- 41.Leisser C, Hirnschall N, Findl O. Effect of air tamponade on tilt of the intraocular lens after phacovitrectomy. Ophthalmologica. 2019;242(2):118–22. 10.1159/000499116. [DOI] [PubMed] [Google Scholar]
- 42.Ti SE, Chee SP, Tan DTH, Yang YN, Shuang SL. Descemet membrane detachment after phacoemulsification surgery: risk factors and success of air bubble tamponade. Cornea. 2013;32(4):454–59. 10.1097/ICO.0b013e318254c045. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
All data generated or analyzed during this study are included in this published article.




