Abstract
Starzak and Starzak (1978. IEEE Trans. Biomed. Eng. 25:201-204.) proposed that, in cyclic application of current and voltage-clamps, the fidelity of the match of the output current with the original stimulus could be used to measure the spatial uniformity of voltage in a membrane. However, they failed to find such a match in experiments on either squid axons or an electronic model of a membrane patch. Computer simulations of such experiments show that the failure to return the initial pattern may arise from shortcomings of the instruments or instability of membrane characteristics. Logical arguments show that such cyclic experiments are not able to provide information about spatial gradients of membrane voltage.
Full text
PDF



Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- COLE K. S., MOORE J. W. Ionic current measurements in the squid giant axon membrane. J Gen Physiol. 1960 Sep;44:123–167. doi: 10.1085/jgp.44.1.123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Cole K. S. Digital operations can be deceptive. Squid giant axon membrane. Biophys J. 1980 Sep;31(3):433–434. doi: 10.1016/S0006-3495(80)85070-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HODGKIN A. L., HUXLEY A. F. A quantitative description of membrane current and its application to conduction and excitation in nerve. J Physiol. 1952 Aug;117(4):500–544. doi: 10.1113/jphysiol.1952.sp004764. [DOI] [PMC free article] [PubMed] [Google Scholar]
- HODGKIN A. L., HUXLEY A. F., KATZ B. Measurement of current-voltage relations in the membrane of the giant axon of Loligo. J Physiol. 1952 Apr;116(4):424–448. doi: 10.1113/jphysiol.1952.sp004716. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Moore J. W., Ramón F., Joyner R. W. Axon voltage-clamp simulations. I. Methods and tests. Biophys J. 1975 Jan;15(1):11–24. doi: 10.1016/S0006-3495(75)85788-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Starzak M. E., Starzak R. J. An action potential clamp to probe the effectiveness of space clamp in axons. IEEE Trans Biomed Eng. 1978 Mar;25(2):201–204. doi: 10.1109/TBME.1978.326249. [DOI] [PubMed] [Google Scholar]