Abstract
OBJECTIVE--To determine the relation between the vibromyographic (VMG) frequency characteristics and fibre composition in postural and non-postural human muscle undergoing a standardised voluntary contraction. METHODS--Two human muscles with different fibre compositions [soleus: postural, mainly type I (slow) fibres; biceps brachii: non-postural, mixed type I and II (fast) fibres] were recorded from 18 healthy males isometrically contracting at 50% of their maximum voluntary contraction (MVC). Muscle vibrations were recorded using a contact microphone and the frequency content of the signals calculated using fast fourier transform algorithms. RESULTS--The non-postural biceps brachii showed predominantly bimodal power spectra with significantly increased power in the 10-30 Hz bands (P < 0.01), as compared with soleus recordings which tended to be unimodal, with the majority of power below 10 Hz. CONCLUSIONS--Muscles with a large proportion of type I fibres generate VMG signals which contain an increased percentage of low frequencies as compared to muscles with a mixed population of type I and type II fibres. The VMG appears to be generated, in part at least, by the mechanical twitching of motor units within the muscle; frequency domain analysis of this signal may provide a non-invasive measure of muscle fibre composition.
Full text
PDF




Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Barry D. T. Acoustic signals from frog skeletal muscle. Biophys J. 1987 May;51(5):769–773. doi: 10.1016/S0006-3495(87)83403-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Barry D. T., Geiringer S. R., Ball R. D. Acoustic myography: a noninvasive monitor of motor unit fatigue. Muscle Nerve. 1985 Mar-Apr;8(3):189–194. doi: 10.1002/mus.880080303. [DOI] [PubMed] [Google Scholar]
- Bellemare F., Woods J. J., Johansson R., Bigland-Ritchie B. Motor-unit discharge rates in maximal voluntary contractions of three human muscles. J Neurophysiol. 1983 Dec;50(6):1380–1392. doi: 10.1152/jn.1983.50.6.1380. [DOI] [PubMed] [Google Scholar]
- Bolton C. F., Parkes A., Thompson T. R., Clark M. R., Sterne C. J. Recording sound from human skeletal muscle: technical and physiological aspects. Muscle Nerve. 1989 Feb;12(2):126–134. doi: 10.1002/mus.880120207. [DOI] [PubMed] [Google Scholar]
- Edgerton V. R., Smith J. L., Simpson D. R. Muscle fibre type populations of human leg muscles. Histochem J. 1975 May;7(3):259–266. doi: 10.1007/BF01003594. [DOI] [PubMed] [Google Scholar]
- Frangioni J. V., Kwan-Gett T. S., Dobrunz L. E., McMahon T. A. The mechanism of low-frequency sound production in muscle. Biophys J. 1987 May;51(5):775–783. doi: 10.1016/S0006-3495(87)83404-5. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Freund H. J. Motor unit and muscle activity in voluntary motor control. Physiol Rev. 1983 Apr;63(2):387–436. doi: 10.1152/physrev.1983.63.2.387. [DOI] [PubMed] [Google Scholar]
- Goldenberg M. S., Yack H. J., Cerny F. J., Burton H. W. Acoustic myography as an indicator of force during sustained contractions of a small hand muscle. J Appl Physiol (1985) 1991 Jan;70(1):87–91. doi: 10.1152/jappl.1991.70.1.87. [DOI] [PubMed] [Google Scholar]
- Gordon G., Holbourn A. H. The sounds from single motor units in a contracting muscle. J Physiol. 1948 Sep 30;107(4):456–464. doi: 10.1113/jphysiol.1948.sp004290. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Keidel M., Keidel W. D. The computer-vibromyography as a biometric progress in studying muscle function. Biomed Tech (Berl) 1989 May;34(5):107–116. doi: 10.1515/bmte.1989.34.5.107. [DOI] [PubMed] [Google Scholar]
- Marchetti M., Felici F., Bernardi M., Minasi P., Di Filippo L. Can evoked phonomyography be used to recognize fast and slow muscle in man? Int J Sports Med. 1992 Jan;13(1):65–68. doi: 10.1055/s-2007-1021237. [DOI] [PubMed] [Google Scholar]
- Maton B., Petitjean M., Cnockaert J. C. Phonomyogram and electromyogram relationships with isometric force reinvestigated in man. Eur J Appl Physiol Occup Physiol. 1990;60(3):194–201. doi: 10.1007/BF00839159. [DOI] [PubMed] [Google Scholar]
- Orizio C., Perini R., Diemont B., Maranzana Figini M., Veicsteinas A. Spectral analysis of muscular sound during isometric contraction of biceps brachii. J Appl Physiol (1985) 1990 Feb;68(2):508–512. doi: 10.1152/jappl.1990.68.2.508. [DOI] [PubMed] [Google Scholar]
- Orizio C., Perini R., Veicsteinas A. Muscular sound and force relationship during isometric contraction in man. Eur J Appl Physiol Occup Physiol. 1989;58(5):528–533. doi: 10.1007/BF02330708. [DOI] [PubMed] [Google Scholar]
- Orizio C., Veicsteinas A. Soundmyogram analysis during sustained maximal voluntary contraction in sprinters and long distance runners. Int J Sports Med. 1992 Nov;13(8):594–599. doi: 10.1055/s-2007-1024572. [DOI] [PubMed] [Google Scholar]
- Rhatigan B. A., Mylrea K. C., Lonsdale E., Stern L. Z. Investigation of sounds produced by healthy and diseased human muscular contraction. IEEE Trans Biomed Eng. 1986 Oct;33(10):967–971. doi: 10.1109/TBME.1986.325668. [DOI] [PubMed] [Google Scholar]
- Smith T. G., Stokes M. J. Technical aspects of acoustic myography (AMG) of human skeletal muscle: contact pressure and force/AMG relationships. J Neurosci Methods. 1993 Apr;47(1-2):85–92. doi: 10.1016/0165-0270(93)90024-l. [DOI] [PubMed] [Google Scholar]
- Stokes I. A., Moffroid M. S., Rush S., Haugh L. D. Comparison of acoustic and electrical signals from erectores spinae muscles. Muscle Nerve. 1988 Apr;11(4):331–336. doi: 10.1002/mus.880110409. [DOI] [PubMed] [Google Scholar]
- Stokes M. J., Cooper R. G. Muscle sounds during voluntary and stimulated contractions of the human adductor pollicis muscle. J Appl Physiol (1985) 1992 May;72(5):1908–1913. doi: 10.1152/jappl.1992.72.5.1908. [DOI] [PubMed] [Google Scholar]
- Zwarts M. J., Keidel M. Relationship between electrical and vibratory output of muscle during voluntary contraction and fatigue. Muscle Nerve. 1991 Aug;14(8):756–761. doi: 10.1002/mus.880140810. [DOI] [PubMed] [Google Scholar]
