Skip to main content
Journal of Applied Clinical Medical Physics logoLink to Journal of Applied Clinical Medical Physics
. 2026 Jul 7;27(7):e70683. doi: 10.1002/acm2.70683

Feasibility study of three‐dimensional dose prediction of esophageal cancer radiotherapy based on CGAN

Qichao Hu 1, Yanrui Li 1, Youyi Tao 1, Yanxia Wang 1, Xudong Kong 2,✉
PMCID: PMC13341968  PMID: 42415304

Abstract

Objective

To evaluate the feasibility of a Conditional Generative Adversarial Network (CGAN)‐based model (2UDCNN‐AT‐GAN) for predicting 3D radiotherapy dose distributions in esophageal cancer, and to assess its potential utility as a guidance tool for Intensity‐Modulated Radiotherapy (IMRT) plan design.

Methods

A CGAN‐based model was trained on 95 esophageal cancer IMRT plans and tested on 15 plans. The model integrated a dual‐path encoder‐decoder, attention‐gated fusion, and Dose‐volume histogram (DVH)‐based conditioning. Predicted dose distributions were compared with manual clinical plans using DVH metrics, plan evaluation parameters, and error analysis.

Results

All predicted plans met clinical constraints (100% qualification rate). Predicted and manual plans identified concordant near‐limit organs at risk (OARs) cases. This consistency mirrored the critical OAR constraints that govern target dose distribution. The mean prediction error was 2.88 ± 2.88% with target errors of 1.00 ± 1.00%. The homogeneity index (0.08 ± 0.02) matched that of manual plans, while the conformity index (CI) was slightly lower (p = 0.0034). The mean Dice Similarity Coefficient (DSC) was 0.916.

Conclusion

In this feasibility study, the 2UDCNN‐AT‐GAN model generated preliminary clinically acceptable dose predictions that met basic clinical constraints and showed spatial similarity to manual plans. A systematic ablation study confirmed that the integrated dual‐path and attention‐gated architecture outperforms individual components, establishing proof‐of‐concept feasibility for esophageal IMRT planning guidance. However, systematic target underdosage and the single‐institution scope limit its current role to a preliminary planning reference.

Keywords: esophageal cancer, generative adversarial networks, radiotherapy, three‐dimensional dose prediction

1. INTRODUCTION

Esophageal cancer is a malignancy with high incidence and mortality rates in China. 1 Patients are frequently diagnosed at advanced stages, necessitating large radiotherapy target volumes. Intensity‐modulated radiotherapy (IMRT) planning is challenging due to irregular and elongated target morphology, dense distribution of radiosensitive organs at risk (OARs) around the esophagus, and stringent OAR dose constraints. These factors make IMRT planning operator‐dependent.

Radiotherapy dose prediction methods, including traditional knowledge‑based planning (KBP) and deep learning, fall under generalized knowledge‑based planning (GKBP). GKBP learns from high‑quality plan datasets to guide new plan design, with three key components: learning objects, methods, and objectives.

Learning targets range from manually extracted features (e.g., Overlap Volume Histogram (OVH), 2 Distance Target Histogram (DTH) 3 , 4 ) to complete data (Computed Tomography (CT) images, contours) containing high‐dimensional feature information. Learning methods include machine learning (generalized principal component analysis (gPCA) 3 , 5 ) and deep learning architectures including convolutional neural networks (CNNs) such as U‐Net, 6 residual U‐Net, 7 Generative Adversarial Network (GAN), 8 , 9 often combined with attention mechanisms. 9 The learning objective is typically DVH parameters or 3D dose distributions.

For esophageal cancer, GKBP studies using manual features (DTH, 10 , 11 multi‐regions of interest (ROI) features 12 ) suffer from restricted informational scope, 13 omission of critical features, 14 and high time consumption. Hence, CT images or contours are used, 15 despite redundancy and extraction challenges. Recent studies have applied U‐Net 16 or residual U‐Net 17 for dose prediction.

Esophageal IMRT faces unique challenges: the Planning Target Volume (PTV) is elongated and irregular with variable OAR proximity, and beams produce broad low‑dose distributions affecting the lungs. A dual‑path encoder‑decoder captures global anatomy and local target morphology, while attention‑gated fusion enhances PTV‑OAR boundaries where dose gradients are steepest. Their integration is hypothesized to improve spatial dose fidelity and OAR sparing. We thus proposed a Conditional Generative Adversarial Network (CGAN) 18 framework integrating a dual‑path U‐Net, 19 attention‐gated 9 fusion, and DVH‑based conditioning—a combination not systematically evaluated for esophageal cancer. This pilot feasibility study assesses clinically acceptable dose prediction, spatial similarity to manual plans, and limitations, aiming to establish technical viability as a preliminary planning reference tool, not clinical equivalence.

2. MATERIALS AND METHODS

2.1. Data collection and processing

We retrospectively analyzed 110 esophageal cancer patients (86 males, median age of 74 years) treated with IMRT (predominantly 5‐field, prescribed as 50 Gy in 25 fractions to cover the PTV D95%). A stratified random test set of 15 cases was selected. Data processing included: (1) CT standardization and 3D reconstruction; (2) extraction of PTV and OARs (lungs, heart, spinal cord), along with voxel labeling and DVH parameters as listed in Table 1; (3) dose resampling and registration; and (4) extraction of multiple contiguous slices (± 4 slices centered on the PTV) for training.

TABLE 1.

Structure labeling and dosimetric parameters.

Structure name Patient Lungs Heart Spinal Cord PTV
Label value  10 13 26 45 47
DVH value None
Dmean,V20,V5
Dmean,V30,V40
Dmax
D95%,D98%,D50%,D2%

2.2. Model development

We proposed a CGAN‑based model named 2UDCNN‑AT‑GAN. The generator synthesized a 256×256 dose map from three inputs: CT images, structure contours, and PTV masks (using five consecutive slices). Normalized DVH parameters of OARs and PTV were added as conditional inputs. The discriminator classified real vs. synthetic dose maps with the same DVH constraints.

The generator used a dual‐path encoder‐decoder (Figure 1). One path processed PTV slices; the other processed CT and contours. The decoder replaced standard skip connections with attention‐gated up‐sampling modules (UP‐AG, Figure 2), which computed attention weights to fuse encoder and decoder features through weighted summation, thereby prioritizing relevant regions and suppressing noise.

FIGURE 1.

FIGURE 1

Neural network architecture of the 2UDCNN‐AT‐GAN model.

FIGURE 2.

FIGURE 2

Implementation mechanism of the UP‐AG.

The objective function, defined by Equation (1), combined adversarial loss and L1 loss:

minGmaxDLD,G=Ex∼pdatax|ylogDx|y+Ez∼pzz|ylog1−DGz|y+λEx∼pdatax|y,z∼pzz|yx−Gz|y1# (1)

where x is the real dose, z is the input (CT, structures, PTV), y are the DVH constraints, and λ=90 balances the L1 penalty.

The model was trained using PyTorch, Adam optimizer (G: 2e‐4, D: 3e‐4), batch size 32. See Table 2 for full configuration.

TABLE 2.

Model training configuration and parameters.

Component Parameter Specification
Core modules DoubleConv [Conv (k, s, p: 3,1,1), BatchNorm, LeakyReLU] ×2
Down [MaxPool (k, s, p: 3,2,1), DoubleConv, ResidualBlock]
UP [UpSample(scale_factor: 2), DoubleConv, UP‐AG]
Pathway channels and size: c(s) a Generator

Encoder: 8(256) →16(256) →32(128) →64(64) →128(32) →256(16) →512(8)

Decoder: 512(8) →256(16) →128(32) →64(64) →32(128) →16(256) →1(256)

Discriminator 2(256) →1(256) →1(128) →1(64) →1(32) →1(16) →1(8) →64(1) →32(1) →16(1) →1(1)
Training setup Optimizer (lr) Adam (G: 2e‐4, D: 3e‐4)
Loss function BCE
Batch size 32
λ (L1 penalty) 90
a

C: channels; S: spatial size (height × width).

2.3. Plan evaluation and model performance metrics

Generated plans were evaluated against clinical constraints (OAR doses), and PTV dose compliance was graded: A (50 Gy ± 1%), B (± 2%), C (± 5%), D (> 5%). Conformity Index: CI=VR∩PTVVPTV, where VR∩PTV is the intersection of an isodose surface with the PTV, and VPTV is the target volume.

Homogeneity Index: HI=D2%−D98%D50%, where Dx% denotes the dose of x% PTV volume. DVH parameters are listed in Table 1. The Dice Similarity Coefficient (DSC) quantifies the spatial overlap between predicted and manual isodose surfaces: DSC=2|A∩B||A|+|B|, where A and B are binary masks of the two regions.

2.4. Statistical analysis

All statistical analyses were performed using SPSS 23.0. DVH‐based parameters were compared between predicted and manual plans using paired tests. Normality of differences was assessed with the Shapiro–Wilk test. Data are mean ± SD or median (IQR) for normal and non‐normal distributions, respectively. Normally distributed data were analyzed with paired t‐tests, while non‐normal data were analyzed with Wilcoxon signed‐rank tests. Bonferroni correction was applied for multiple comparisons across eight parameters (significance threshold: α=0.0068). The percentage difference for each DVH parameter was calculated using Equation 2, where DVHprediction and DVHreal represent the predicted and clinical manual plan values, and DVHprescription is the prescribed dose.

DVHΔ=DVHprediction−DVHrealDVHprescription×100 (2)

3. RESULTS

All predicted plans met clinical dose constraints (100% pass rate). Quantitative comparisons between predicted and manual plans were summarized in Tables 3 and 4. Predicted plans showed systematic differences from manual plans. The mean PTV D95% was 49.23 ± 0.71 Gy (manual: 49.79 ± 0.27 Gy), and only 6 of 15 predicted plans achieved a “Plan A” rating compared to the vast majority of manual plans. The CI was significantly lower in predicted plans (p=0.0034), while the HI was comparable (0.08 ± 0.02 vs. 0.08 ± 0.01). The mean prediction error across all DVH parameters was 2.88 ± 2.88%, with the target error lower (1.00 ± 1.00%) than that of OARs.

TABLE 3.

Dosimetric parameter comparisons between predicted and manual plans: Differences and statistical significance (p‐values).

Clinical indices Predicted plan Manual plan p‐value Difference

Overall average

error

PTV 𝐷95% 50 Gy 49.23 ± 0.71 Gy 49.79 ± 0.27 Gy 0.0089 1.00 ± 1.00% 2.88 ± 2.88%
Lungs 𝐷mean ≤13 Gy 7.24 ± 2.60 Gy 7.53 ± 2.70 Gy 0.0246 3.00 ± 2.00%
Lungs 𝑉20 ≤25% 12.55 ± 6.32% 13.26 ± 6.35% 0.2816 8.00 ± 7.00%
Lungs 𝑉5 ≤60% 39.34 ± 3.93% 38.86 ± 3.17% 0.3536 2.00 ± 2.00%
Heart 𝐷𝑚𝑒𝑎n ≤26 Gy 1.22(0.09,8.19) 1.22(0.09,7.05) 0.0630 1.00 ± 1.00%
Heart 𝑉30 ≤40% 0.00(0.00,8.59) 0.00(0.00,6.75) 0.1282 2.00 ± 3.00%
Heart 𝑉40 ≤30% 0.00(0.00,3.52) 0.00(0.00,2.65) 0.0425 1.00 ± 2.00%
Spinal Cord 𝐷max ≤50 Gy 41.25 ± 6.88 Gy 41.32 ± 8.16 Gy 0.9468 6.00 ± 5.00%
HI 0.08 ± 0.02 0.08 ± 0.01 0.3560 /
CI 0.90(0.80,0.94) 0.95(0.94,0.96) 0.0034

TABLE 4.

Comparative distribution of predicted vs. manual plans across four quality grades.

Plan grading assessment
A (50 Gy ± 1%) B (50 Gy ± 2%) C (50 Gy ± 5%) D (≥5%)
Manual plan 14 1 0 0
Predicted plan 6 4 5 0

Table 5 presents the model's predictions for representative boundary cases selected from the 15 test plans (the case with the minimum PTV D95% and those where OAR doses were closest to their respective clinical constraints). The near‐limit OAR cases in the model predictions were concordant with those in the manual plans.

TABLE 5.

Boundary cases: Predicted vs. manual plans with minimum PTV D95% and near‐limit OAR doses.

Cases PTV Lungs Heart Spinal cord
𝐷95% 𝑉20 𝑉5 𝐷mean 𝑉40 𝑉30 𝐷mean 𝐷max
Predicted plan Case 2 49.33 20.41 53.04 10.43 9.22 3.35 5.88 48.66
Case 8 47.78 7.87 30.79 5.17 0.00 0.00 0.00 42.10
Case 9 50.31 7.43 35.08 6.67 11.45 5.28 16.19 36.03
Case 15 49.29 23.28 55.66 11.07 0.00 0.00 0.00 43.94
Manual plan Case 2 49.77 22.00 51.85 11.04 6.49 1.66 5.81 49.77
Case 9 50.52 14.23 38.29 7.70 12.22 5.44 16.71 34.10
Case 15 49.74 22.1 50.37 10.57 0.00 0.00 1.22 46.39

Spatial similarity, measured by the DSC across 14 isodose levels (15–50 Gy), produced a mean DSC of 0.916 (Figure 3). Representative case analyses are shown in Figures 4 and 5. Figure 4 presents DVH curves for two “A”‐graded predicted plans (Cases 6 and 11) alongside their manual plans. Key constraints (e.g., lung V5≤60%, V20≤25%) and PTV D95% are marked. Solid and dashed lines represent manual and predicted plans, respectively; structures are color coded (PTV in red, spinal cord in yellow, heart in purple, lung in green). Figure 5 compares predicted and manual dose distributions for Case 6 at a mid‐PTV slice (first row) and a non‐PTV slice (second row), including absolute difference maps (calculated as DoseΔ=|Doseprediction−Dosereal|). Table 6 quantifies the pixel‐wise Mean Absolute Error (MAE) within the patient contour for both slices in Cases 6 and 11.

FIGURE 3.

FIGURE 3

DSC comparison of isodose surfaces between automated and manual radiotherapy plans (14 dose gradients across 15 cases).

FIGURE 4.

FIGURE 4

DVH curve comparison between predicted and manual plans for two A‐graded cases.

FIGURE 5.

FIGURE 5

Case 6: Dose distribution in the mid‐PTV slice and non‐PTV slice.

TABLE 6.

Dose distribution discrepancy analysis: Predicted vs. manual plans in mid‐PTV and non‐PTV slices (pixel‐wise MAE within the patient contour, case 6 & 11).

Case mid‐PTV slice (Gy) non‐PTV slice (Gy)
Case 6 1.29 1.99
Case 11 0.7 2.94

In an ablation study under identical training conditions, we compared four variants: Baseline, Dual, AG, and AG‑Dual (Table 7). The full AG‑Dual model achieved the lowest MAE (0.0439) and root mean square error (RMSE: 0.1123), lungs 𝑉20 error (24.14%), heart 𝐷𝑚𝑒𝑎n error (7.30%), and spinal cord 𝐷max error (13.45%), as well as the highest mean DSC (0.7622) and DSC@40 Gy (0.8534). Although the AG variant showed slightly lower PTV 𝐷95%/𝐷98% errors, AG‑Dual provided substantially better OAR protection and spatial accuracy, confirming complementary benefits between the two components.

TABLE 7.

Ablation study results comparing four model variants.

Error (%)
Model MAE RMSE

PTV

𝐷95%

PTV

𝐷98%

Lung

𝑉20

Heart

𝐷mean

SC

𝐷max

Mean DSC DSC@40 Gy
Baseline 0.0492 0.1285 8.20 10.21 64.57 14.03 25.56 0.6380 0.6381
Dual 0.0496 0.1353 5.79 7.62 31.53 16.45 15.09 0.7498 0.8181
AG 0.0528 0.1711 4.21 4.71 45.12 11.14 18.53 0.7119 0.7144
AG‐Dual 0.0439 0.1123 5.37 7.88 24.14 7.30 13.45 0.7622 0.8534

Note: Bold values indicate optimal performance. Error(%)=|DVHpred−DVHreal|DVHreal×100. DSC@40 Gy denotes the DSC at the 40 Gy isodose surface. SC denotes the Spinal Cord. Individual per patient data are available in Table S1.

4. DISCUSSION

This study evaluated a CGAN‑based model for predicting 3D dose distributions in esophageal cancer IMRT, assessing its feasibility as a planning reference (not an autonomous plan generator).

The model demonstrated several promising characteristics. All predicted OAR doses satisfied clinical constraints (100% pass rate, Table 4). The mean prediction error was 2.88% ± 2.88% overall, with PTV errors lower (1.00% ± 1.00%, Table 3). The mean DSC across 14 isodose levels was 0.916, indicating moderate‑to‑high spatial similarity to manual plans (Figure 3). Beyond basic acceptability, the model and manual plans identified the same near‐limit OAR cases that most constrained PTV coverage.

Ablation results (Table 7) revealed complementary roles of the two modules. Dual alone improved spatial dose fidelity (DSC@40 Gy +28.2%) and reduced lungs/spinal cord errors, but increased MAE/RMSE slightly. AG alone excelled at target coverage (PTV 𝐷95%/𝐷98% errors reduced by ∼50%) and heart 𝐷mean error, yet RMSE rose by 33.2%. The integrated AG‐Dual model achieved the best balance: lowest MAE/RMSE, highest DSC@40 Gy (0.8536), and optimal OAR sparing. The dual‑path stabilizes global dose distribution; AG sharpens critical boundaries. This confirms our hypothesis that both modules address distinct challenges of esophageal IMRT—their synergy yields superior overall performance.

Based on these capabilities, the model's predictions offer practical guidance for IMRT plan design in three main ways. First, the predicted DVH values (e.g., lungs V5, V20, spinal cord

Dmax) can be used as initial optimization constraints, providing a reasonable starting point for inverse planning. Second, by pinpointing the dose‐limiting factors (“bottlenecks”) that limit target dose delivery—i.e., identifying which OAR most constrains the PTV—planners can prioritize that OAR during optimization (e.g., by assigning higher weighting factors, adjusting beam directions, or relaxing less critical objectives). Third, the predictions help assess the potential for target dose escalation. When predicted OAR doses are well below their tolerance limits, there is considerable room to increase PTV dose without violating constraints; for example, in Case 8 (Table 5), low predicted lung and heart doses suggest a possibility for dose escalation.

These characteristics indicate that the model could provide initial, evidence‑based guidance for setting planning objectives. However, the observed systematic underdosage currently limits its use to hypothesis generation rather than direct plan acceptance.

Major limitations: (1) systematic target underdosage (only 40% achieved grade A, lower CI, p=0.0034; PTV D95% difference did not reach significance after Bonferroni correction, p=0.0089>0.0068). This reflects that the absolute prediction errors remain above clinically ideal thresholds, despite the architectural improvements demonstrated in the ablation study (Table 7); (2) single‐institution test set (n = 15) limits statistical power and generalizability.

Additionally, larger OAR errors occurred in non‐PTV regions with steep dose gradients (Figure 5; Table 6). These errors are likely due to field‐edge dose fall‐off, anatomical variation, and the slice‐based approach lacking full 3D correlations. Limited training data and missing beam geometry may also contribute to these discrepancies.

Future work will focus on fully 3D models using multi‐institutional datasets, corrections for target underdosage (e.g., modified loss functions), and direct comparisons with state‐of‐the‐art methods (e.g., DoseGAN). Hence, this study is a proof‐of‐concept feasibility assessment: the model provides preliminary dose estimates for planning reference, not clinical equivalence.

5. CONCLUSION

In this feasibility study, the 2UDCNN‑AT‑GAN model generated preliminary dose predictions that met basic clinical constraints and showed moderate‑to‑high spatial similarity to manual plans. However, while an ablation study demonstrated the complementary benefits of the dual‐path and AG components, systematic target underdosage and the limited test set size restricts its current role to a proof‑of‑concept planning reference. Future work will focus on multi‐institutional validation, fully 3D architectures, and target coverage corrections.

SUPPLEMENTARY DATA

The file Supplementary Table S1.xlsx contains per patient pixel‐wise errors (normalized dose domain) and Dice similarity coefficients for all four models. The README sheet explains all abbreviations and the normalization range.

AUTHOR CONTRIBUTIONS

Qichao Hu: Methodology, investigation, writing—original draft, validation, software. Xudong Kong: Supervision, project administration. Yanrui Li: Resources, formal analysis, data curation, validation, writing—review and editing. Youyi Tao: Conceptualization, investigation, formal analysis, visualization, writing—review and editing. Qichao Hu, Yanrui Li and Youyi Tao: Contributed equally to this work. Yanxia Wang: Resources, data curation, validation.

CONFLICT OF INTEREST STATEMENT

The authors declare no conflicts of interest.

ETHICAL APPROVAL

This retrospective study was reviewed and approved by the Medical Ethics Committee of Donghai County People's Hospital (approval No. 2025‐KY‐008, dated May 30, 2025). The requirement for informed consent was waived by the same committee under Article 39 of the Ethical Review Measures for Biomedical Research Involving Human Subjects (《涉及人的生物医学研究伦理审查办法》, National Health Commission of China), as the study involved analysis of fully de‐identified hospital records with no direct patient contact, experimental interventions, or collection of identifiable personal information. All direct identifiers (e.g., names, ID numbers, admission dates) were removed prior to analysis, and data handling followed institutional privacy protection protocols to prevent re‐identification.

Supporting information

Supporting Information

ACM2-27-e70683-s001.pdf (681.4KB, pdf)

Supporting Information

ACM2-27-e70683-s002.xlsx (21.6KB, xlsx)

ACKNOWLEDGMENTS

Special gratitude is extended to the anonymous reviewers whose suggestions significantly improved this manuscript and an anonymous colleague whose steadfast encouragement and discreet assistance were indispensable to this research. This work is associated with the 2025 Lianyungang Association for Science and Technology Soft Science Project (Project No. LYGKXLXKT042), which was approved under Category C (‘Approved without Funding’) and has been completed. No financial funding was received for this study. No grants, institutional subsidies, or commercial support were provided for the study design, data collection, analysis, manuscript preparation, or publication.

DATA AVAILABILITY STATEMENT

The data that support the findings of this study are available within the article. Raw patient data are not publicly available due to privacy restrictions under applicable Chinese law and institutional policy. Requests for de‐identified data may be directed to the corresponding author.

REFERENCES

  • 1. Han B, Zheng R, Zeng H, et al. Cancer incidence and mortality in China, 2022. J Natl Cancer Cent. 2024;4(1):47‐53. doi: 10.1016/j.jncc.2024.01.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2. Wu B, Ricchetti F, Sanguineti G, et al. Data‐driven approach to generating achievable dose‐volume histogram objectives in intensity‐modulated radiotherapy planning. International Journal Of Radiation Oncology, Biology, Physics. 2011;79(4):1241‐1247. doi: 10.1016/j.ijrobp.2010.05.026 [DOI] [PubMed] [Google Scholar]
  • 3. Zhu X, Ge Y, Li T, Thongphiew D, Yin FF, Wu QJ. A planning quality evaluation tool for prostate adaptive IMRT based on machine learning. Med Phys. 2011;38(2):719‐726. doi: 10.1118/1.3539749 [DOI] [PubMed] [Google Scholar]
  • 4. Lian J, Yuan L, Ge Y, et al. Modeling the dosimetry of organ‐at‐risk in head and neck IMRT planning: an intertechnique and interinstitutional study. Med Phys. 2013;40(12):121704. doi: 10.1118/1.4828788 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Yuan L, Ge Y, Lee WR, Yin FF, Kirkpatrick JP, Wu QJ. Quantitative analysis of the factors which affect the interpatient organ‐at‐risk dose sparing variation in IMRT plans. Med Phys. 2012;39(11):6868‐6878. doi: 10.1118/1.4757927 [DOI] [PubMed] [Google Scholar]
  • 6. Kajikawa T, Kadoya N, Ito K, et al. Automated prediction of dosimetric eligibility of patients with prostate cancer undergoing intensity‐modulated radiation therapy using a convolutional neural network. Radiol Phys Technol. 2018;11(3):320‐327. doi: 10.1007/s12194-018-0472-3 [DOI] [PubMed] [Google Scholar]
  • 7. He K, Zhang X, Ren S, Sun J, eds. Deep residual learning for image recognition. 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR); 2016.doi: 10.1109/CVPR.2016.90 [DOI]
  • 8. Mahmood R, Babier A, McNiven A, Diamant A, Chan TCY. Automated treatment planning in radiation therapy using generative adversarial networks.2018. July 01, 2018:[arXiv:1807.06489 p.]. https://ui.adsabs.harvard.edu/abs/2018arXiv180706489M
  • 9. Kearney V, Chan JW, Wang T, et al. DoseGAN: a generative adversarial network for synthetic dose prediction using attention‐gated discrimination and generation. Sci Rep. 2020;10(1):11073. doi: 10.1038/s41598-020-68062-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Jiang D, Li T, Mao R, Du C, Liu J. Deep learning based dosimetry evaluation at organs‐at‐risk in esophageal radiation treatment planning. 2019;2019:868‐871. doi: 10.1109/embc.2019.8856819 [DOI] [PubMed] [Google Scholar]
  • 11. Jiang D, Yan H, Chang Na, et al. Convolutional neural network‐based dosimetry evaluation of esophageal radiation treatment planning. Med Phys. 2020;47(10):4735‐4742. doi: 10.1002/mp.14434 [DOI] [PubMed] [Google Scholar]
  • 12. Li W Research on DVH prediction of IMRT plan based on ABC‐BP method for esophageal cancer [Master's thesis]. China West Normal University; 2020. https://link.cnki.net/doi/10.27859/d.cnki.gxhsf.2020.000141 [Google Scholar]
  • 13. Chen XY, Men K, Li YX, Yi JL, Dai JR. A feasibility study on an automated method to generate patient‐specific dose distributions for radiotherapy using deep learning. Med Phys. 2019;46(1):56‐64. doi: 10.1002/mp.13262 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14. Liu Z, Fan J, Li M, et al. A deep learning method for prediction of three‐dimensional dose distribution of helical tomotherapy. Med Phys. 2019;46(5):1972‐1983. doi: 10.1002/mp.13490 [DOI] [PubMed] [Google Scholar]
  • 15. Babier A, Mahmood R, McNiven AL, Diamant A, Chan TCY. Knowledge‐based automated planning with three‐dimensional generative adversarial networks. Med Phys. 2020;47(2):297‐306. doi: 10.1002/mp.13896 [DOI] [PubMed] [Google Scholar]
  • 16. Wang J, Mao R, Liu J, Liu J, eds. Study on dose distribution prediction of esophageal cancer patients using u‐net model. Proceedings of 2019 Chinese Intelligent Systems Conference. Springer Singapore; 2020.<bib> [Google Scholar]
  • 17. Wang W. A study on automatic planning for intensity‐modulated radiotherapy of postoperative esophageal cancer base on deep learning. [Master's thesis]. Anhui: Anhui Medical University; 2022. https://link.cnki.net/doi/10.26921/d.cnki.ganyu.2022.000804 [Google Scholar]
  • 18. Mirza M, Osindero S, Conditional Generative Adversarial Nets.2014 November 01, 2014:[arXiv:1411.784 p.]. https://arxiv.org/abs/1411.1784
  • 19. Fan JW, Wang JZ, Chen Z, Hu CS, Zhang Z, Hu WG. Automatic treatment planning based on three‐dimensional dose distribution predicted from deep learning technique. Med Phys. 2019;46(1):370‐381. doi: 10.1002/mp.13271 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supporting Information

ACM2-27-e70683-s001.pdf (681.4KB, pdf)

Supporting Information

ACM2-27-e70683-s002.xlsx (21.6KB, xlsx)

Data Availability Statement

The data that support the findings of this study are available within the article. Raw patient data are not publicly available due to privacy restrictions under applicable Chinese law and institutional policy. Requests for de‐identified data may be directed to the corresponding author.


Articles from Journal of Applied Clinical Medical Physics are provided here courtesy of Wiley

RESOURCES