Training and validation of a 1D CNN model for accurate three-class classification of oral cancer using serum Raman spectroscopy

Mukta Sharma 1,✉, Shiang-Fu Huang 2
PMCID: PMC13341985  PMID: 42135513

Abstract

In this study, a one-dimensional convolutional neural network (1D-CNN) was developed for classifying serum Raman spectra into three oral cancer-related classes: normal, precancerous, and cancerous. To address class imbalance, class-weighted learning was employed during training, while augmentation was evaluated separately as a comparative strategy. The final selected non-augmented model achieved an overall testing accuracy of 83%, with a macro-precision of 85%, macro-recall of 84%, and macro-F1 score of 83%, indicating balanced three-class performance. To further assess real-world applicability, an independent test dataset collected later from the same hospital was used. This cohort followed the same acquisition and preprocessing protocol but consisted of entirely new patients. The model maintained consistent classification performance on this independent dataset, supporting its generalizability within the same clinical environment. These findings highlight the potential of combining Raman spectroscopy with deep learning as a non-invasive framework for oral cancer-related biosample classification.

Keywords: Oral cancer, Raman spectroscopy, Convolutional neural network, Serum

Introduction

Oral cancer remains one of the leading causes of morbidity and mortality worldwide, with late-stage diagnosis being a critical challenge that significantly reduces survival rates [1]. Globally, in 2020 there were an estimated 377,713 new cases of oral cancer (13th most common cancer worldwide) and 177,757 deaths [2]. The most common form of oral cancer is oral squamous cell carcinoma (OSCC). Oral potentially malignant disorders (OPMDs), such as leukoplakia, oral lichen planus, and erythroplakia, are oral mucosal lesions with a higher risk of progressing to oral cancer. Early recognition of OPMDsis critical while plays a pivotal role in improving patient outcomes, but frontline healthcare providers—including primary care physicians, nurses, dentists, and hygienists—often lack the training to reliably distinguish OPMDs and OSCC from benign lesions [3]. Conventional diagnostic methods, including histopathology and biopsy, remain the gold standard but are invasive, time-consuming, and resource-intensive. These barriers, combined with gaps in knowledge and weak communication with specialists, contribute significantly to delayed diagnosis and treatment. This has prompted growing interest in the development of non-invasive, rapid, and accurate diagnostic methods for early-stage screening.

Raman spectroscopy has emerged as a promising label-free, optical technique capable of providing detailed biochemical fingerprints of biological samples, including serum, saliva, and tissue [4–8]. It has emerged as a promising tool in clinical research, particularly for the identification and diagnosis of oral cancer [9]. It offers high sensitivity to molecular changes associated with malignancy and has shown potential for cancer detection across various tissue types. However, the complex and high-dimensional nature of Raman spectral data poses challenges for traditional statistical analysis, particularly when dealing with small and imbalanced clinical datasets. In this study, serum was chosen as a reliable and stable biofluid for Raman spectroscopic analysis. Although both serum and saliva show a progressive increase in sialic acid levels from normal to OPMD and oral cancer [10], serum provides a more robust and consistent biomarker profile due to its higher sialic acid concentration and lower susceptibility to external influences such as oral hygiene, diet, circadian rhythm, and microbial activity [11]. Compared with other biofluids like saliva or urine, blood and serum-based assays offer greater stability, reproducibility, and ease of repeated sampling [12]. Moreover, serum better reflects systemic tumor-associated biochemical changes, making it particularly suitable for accurate and reproducible spectral classification [13].

With the increasing application of Raman spectroscopy, data-driven deep learning methods have gained wide attention. End-to-end approaches such as Convolutional Neural Networks (CNNs) have been successfully applied to spectral classification, with progress reported in different fields [14]. These advances highlight the strengths of deep learning in signal extraction, feature learning, and modeling complex spectral relationships. However, the integration of Raman spectroscopy with deep learning still faces challenges, particularly due to the ’black-box’ nature of these models, which limits interpretability and raises concerns for clinical deployment [15]. Reliable and explainable predictions are therefore essential to build trust in such systems. Deep learning methods such as CNNs have demonstrated superior performance in spectral analysis and biomedical signal classification [16]. Unlike classical machine learning methods, CNNs can directly learn hierarchical patterns from raw or preprocessed input, making them well-suited for biomedical signal analysis [17]. However, the limited availability of biomedical spectral datasets often leads to class imbalance and overfitting. Data augmentation techniques, including jittering, scaling, and shifting, have been widely employed to expand training sets and improve generalization [18–20]. Although generative AI techniques are advancing rapidly, data augmentation remains a simpler and well-established strategy in spectroscopy, offering an effective means to enhance limited datasets and improve model generalization [21].

In this study, we present a 1D-CNN architecture designed to classify serum Raman spectra into three diagnostic categories relevant to oral cancer: normal, precancer, and cancer. To address class imbalance, a class-weighted learning strategy was adopted during CNN training, while spectral augmentation was evaluated separately as a comparative strategy. To assess the effect of augmentation, the classification performance of the 1D-CNN model was compared under two settings: training without augmentation and training with augmentation. Under the present experimental configuration, the non-augmented model achieved better overall performance. In addition to internal testing through repeated random hold-out evaluation, we employed a temporally separated independent test set comprising newly collected samples from the same hospital to assess real-world generalization. This design ensured that the model encountered previously unseen cases reflective of a practical clinical environment. By integrating Raman spectroscopy with deep learning, this study aims to advance non-invasive approaches for early detection and risk stratification of oral cancer.

Materials and methods

Sample preparation and data acquisition

This study was approved by the Institutional Review Board (Chang Gung Medical Foundation, Taiwan; IRB Nos. 202300682B0 and 201800439B0). Written informed consent was obtained from all participants. The study was carried out at the Department of Otolaryngology Head and Neck Surgery, Chang Gung Memorial Hospital, and enrolled patients with histologically confirmed oral lesions, including 42 (oral squamous cell carcinoma, OSCC) and 39 precancerious cases. Serum samples were collected from participants representing three diagnostic categories: class1 (Cancer, n = 42), class 2 (Precancer, n = 39), and class 3 (Normal = 20). The demographic details of the study cohorts are presented in Table 1. The analyzed dataset comprised 210 spectra from cancer patients, 195 spectra from precancer cases, and 100 spectra from healthy subjects. After averaging the multiple measurements obtained for each subject, the final dataset consisted of 42 cancer, 39 precancer, and 20 healthy samples. All blood serum samples were collected in sterile plastic serum collection tubes without anticoagulant. After clot formation, samples were centrifuged at 3000 rpm for 15 min to separate the serum. The isolated serum was aliquoted into sterile microcentrifuge tubes and stored at - 80 Inline graphicC for long-term stability until further Raman analysis. Before analysis, samples were thawed under controlled conditions and processed according to the experimental protocol. Serum Raman spectra were recorded using a confocal Micro Raman Identify system (ProTrusTech Co., Ltd., Tainan, Taiwan) equipped with a 532 nm excitation laser. The nominal maximum laser power of the instrument is approximately 126 mW; however, in the present study, the laser power at the sample was limited to Inline graphic 31.5 mW to avoid photothermal effects and sample degradation. Before each measurement session, wavelength calibration was performed using a silicon wafer by confirming the characteristic Raman peak at 520 Inline graphic. Spectra were collected with an integration time of 10 s and 3 s accumulations for each sample. For each patient, five Raman measurements were acquired and averaged to obtain one representative spectrum per subject. This strategy, consistent with prior spectroscopic studies, ensured that classification was performed at the patient level, thereby reducing intra-sample variability and avoiding bias from repeated measurements [22].

Table 1.

Clinical and demographic profile of the study cohort (Inline graphic)

Variable Category Age (mean ± SD) Gender (M:F)
Overall All Samples Inline graphic   93 : 8
Group Malignant Inline graphic   37 : 5
Premalignant Inline graphic   36 : 3
Normal Inline graphic   20 : 0
Statistics p-value 0.027 –
Total Count 101

Data preprocessing and analysis

All spectral preprocessing and data analysis were carried out in MATLAB (R2018a, MathWorks, USA). To reduce high-frequency noise and improve spectral smoothness, the raw Raman spectra were first filtered using a third-order Savitzky–Golay smoothing algorithm. Baseline correction was then applied to remove background contributions and fluorescence-related drift. Following this, the spectra were normalized using an area-under-the-curve (AUC) approach to minimize intensity variation and reduce data redundancy across samples. In this normalization procedure, each spectral intensity value was scaled relative to the total integrated area of the corresponding spectrum, thereby standardizing the spectra prior to subsequent analysis. After preprocessing, principal component analysis (PCA) was applied for dimensionality reduction. PCA was fitted using the training data only, and the number of retained principal components was selected to preserve more than 99% of the cumulative variance. The testing data were then projected into the same PCA space using the coefficients derived from the training set. In the present study, we analyzed serum Raman spectra from 42 oral cancer, 39 precancer, and 20 healthy cases, representing an inherently imbalanced dataset. Addressing class imbalance is important for reliable classification performance. In general, imbalance may be handled using data-level approaches, such as undersampling, oversampling, or augmentation, or algorithm-level approaches, such as class weighting or threshold adjustment [5]. In this study, class imbalance was primarily addressed through a class-weighted learning strategy while retaining all original samples. The dataset was partitioned at the patient level into training (70%) and testing (30%) subsets, and the 1D-CNN model was trained on the original training data and evaluated on the corresponding unseen test set. This procedure was repeated across multiple random hold-out runs to improve robustness and reduce dependence on a single data split. Data augmentation was additionally evaluated as a comparative strategy, but the non-augmented configuration yielded better overall performance. Finally, an out-of-distribution cohort collected later from newly recruited patients was used for independent evaluation of model generalizability.

Data augmentation

To expand the training dataset and mitigate overfitting, each training sample was augmented using jittering (Gaussian noise addition), scaling (multiplicative intensity variation), and shifting (spectral axis translation). These methods were chosen to simulate realistic Raman acquisition variability while preserving the underlying biochemical structure of the spectra. In particular, shifting was used to model small Raman shift variations during acquisition and to improve the robustness of CNN-based feature extraction to minor peak-position changes. The dataset was first partitioned into training and testing subsets at the patient level to ensure complete separation between model development and evaluation. Data augmentation was then applied exclusively to the training set, where each original spectrum was augmented eight times, resulting in a ninefold expansion of the training data, while the testing set remained unchanged. The augmentation was implemented via a custom function (augmentSpectrum) that applied Gaussian noise with a noise level of 0.01, multiplicative scaling in the range 0.95-−1.05, and spectral shifting in the range of Inline graphic to Inline graphic Raman units. These parameters were empirically selected to introduce realistic spectral variability while preserving the underlying biochemical characteristics of the original spectra. However, an additional comparative analysis showed that, under the present experimental setting, the model trained on the original non-augmented spectra achieved better overall performance than the augmented-data model. This suggests that the selected augmentation strategy did not improve generalization for the current dataset and may have introduced synthetic variability that was less representative of the true Raman spectral distribution.

CNN architecture design

A one-dimensional Convolutional Neural Network (1D-CNN) was developed for classification of Raman spectra into three diagnostic categories as shown in Fig. 1. The PCA-transformed spectra were used as input to the 1D-CNN model. The network architecture comprised three sequential convolutional blocks, each including a convolution layer with 64 filters and a kernel size of Inline graphic, followed by batch normalization and Leaky ReLU activation. Max-pooling layers with a pooling size of Inline graphic and a stride of 1X4 were applied after the first two convolutional blocks to progressively reduce spectral dimensionality while preserving relevant features.

Fig. 1.

Fig. 1

Architecture of the one-dimensional convolutional neural network (1D-CNN) used for three-class classification of serum Raman spectra (Normal, Precancer, and Cancer)

Following convolutional feature extraction, the model included a fully connected layer with 64 neurons, followed by Leaky ReLU activation and a dropout layer with a rate of 0.5 to reduce overfitting. A final fully connected layer with three output neurons and softmax activation was used for three-class classification. The architecture of the proposed 1D-CNN model is summarized in Table 2. The model was trained using the Adam optimizer with an initial learning rate of 0.001, a mini-batch size of 4, and a maximum of 10 epochs. Overall, the architecture was designed to balance efficient feature extraction with robust generalization for a relatively small and imbalanced Raman dataset.

Table 2.

Architecture of the 1D-CNN model designed for three-class classification of serum Raman spectra. The network utilizes Inline graphic kernels to perform convolutions exclusively along the spectral axis, ensuring feature extraction is focused on vibrational modes

Model Type Filters Size Strides Epoch
1D-CNN Conv layer 64 [1 Inline graphic 8] 1 10
BatchNorm – – –
LeakyReLU – – –
MaxPooling2D – [1 Inline graphic 2] [1 Inline graphic 4]
Conv layer 64 [1 Inline graphic 8] 1
BatchNorm – – –
LeakyReLU – – –
MaxPooling2D – [1 Inline graphic 2] [1 Inline graphic 4]
Conv layer 64 [1 Inline graphic 8] 1
BatchNorm – – –
LeakyReLU – – –
Fully Connected 64 – –
LeakyReLU – – –
Dropout – – –
Fully Connected 3 – –
Softmax – – –
Classification – – –

Model evaluation

For multi-class classification, precision, recall, and F1-score are considered important complementary metrics because they provide class-sensitive performance assessment beyond overall accuracy [23]. Precision measures the proportion of predicted samples in a class that are truly correct, whereas recall measures the proportion of actual samples in a class that are correctly identified. The F1-score provides a balanced measure by combining precision and recall. A confusion matrix was constructed for each run, from whcih accuracy, precision, recall, and F1-score were calculated for each class. For multi-class evaluation, macro-precision, macro-recall, and macro-F1 were also calculated by averaging performance equally across classes, while weighted-F1 was computed by accounting for class size. The corresponding calculation formulas are presented in Eqs. (1)–(8). where Inline graphic, Inline graphic, and Inline graphic denote the true positives, false positives, and false negatives for class Inline graphic, respectively; Inline graphic is the total number of classes; Inline graphic is the number of samples in class Inline graphic; and Inline graphic is the total number of samples. Model performance was evaluted on the corresponding unseen test set using multiple classification metrics. Training and testing accuracy and loss were recorded across epochs, and the mean ± standard deviation (SD) curves over repeated runs were used to assess convergence behavior, robustness, and model generalization.

graphic file with name d33e444.gif 1
graphic file with name d33e448.gif 2
graphic file with name d33e452.gif 3
graphic file with name d33e456.gif 4
graphic file with name d33e460.gif 5
graphic file with name d33e464.gif 6
graphic file with name d33e468.gif 7
graphic file with name d33e472.gif 8

Independent validation data set

For independent validation, we employed a temporally separated dataset collected at a later period from the same hospital. The acquisition protocol, instrumentation, and preprocessing steps were consistent with those used for the training and testing datasets. However, all validation samples were obtained from newly recruited patients, ensuring no overlap with the original dataset and reflecting a real-world scenario where the model encounters unseen cases in the same clinical environment.

Results and discussion

Spectral assignments

The recorded Raman spectra from serum samples exhibited several characteristic vibrational modes associated with biomolecular changes in oral cancer progression, can be seen in Fig. 2. Prominent peaks were observed in the regions corresponding to proteins (amide I and III bands), lipids, and nucleic acids. Comparative inspection revealed subtle but consistent variations between the three diagnostic classes. In the Normal group, characteristic carotenoid peaks at 1006 Inline graphic, 1156 Inline graphic and 1524 Inline graphic, along with a collagen-associated band at 1205 Inline graphic, were more prominent compared to the precancer group. Comparative analysis of the average Raman spectra for normal and cancer groups revealed significant variations in both peak intensities and frequency shifts, particularly in regions associated with protein amide bands and lipid vibrations. While normal samples exhibited stronger carotenoid and collagen signals, the cancer group demonstrated enhanced features at 754 Inline graphic, 1450 Inline graphic and 1656 Inline graphic, corresponding to heme, CH2 bending vibrations, and the amide I band, respectively. Similarly, the cancer versus precancer spectra displayed distinct spectral features dominated by protein and phospholipid bands, again with notable peaks at 754 Inline graphic, 1450 Inline graphic, and 1656 Inline graphic. Additional tryptophan-related bands appeared between 1306–1346 Inline graphic, characterized by overlapping contributions from multiple biomolecules [24]. These included CH bending and twisting vibrations in DNA/RNA, lipid acyl chains, protein side chains, and nucleic acid bases such as guanine. Key spectral hallmarks of cancer samples were a broad and intense amide I band at 1656 Inline graphic and a strong CH2 bending vibration at 1450 Inline graphic, reflecting alterations in protein secondary structure and lipid content [25]. The Raman peak observed near 1244 Inline graphic corresponds to the Amide III band, which arises from vibrations of the protein backbone [26]. This mode primarily involves a combination of C–N stretching and N–H bending. The precise position and intensity of the Amide III band are highly sensitive to the secondary structure of proteins, reflecting contributions from alpha-helices, beta-sheets, and random coil conformations. In serum samples, this band serves as a strong indicator of overall protein content and structure, particularly reflecting the presence of major proteins such as albumins and globulins. All assignments of peaks are summarized in Table 3.

Fig. 2.

Fig. 2

Average Raman spectra of serum collected from normal (blue curve), precancer (red curve) and cancer patients suffering from oral cancer (black curve)

Table 3.

Key Raman spectral peaks and their biochemical assignments in serum samples

Peak position (cmInline graphic) Band assignment Vibrational mode References
754 Tryptophan Ring breathing, protein marker [27]
1006 Carotenoids Ring breathing [28]
1156 Carotenoids C–C stretching [28]
1205 Collagen C–CInline graphicHInline graphic vibration [29]
1244 Amide III C–N stretching, N–H bending [26]
1306–1346 Tryptophan / nucleic acids CH bending, twisting [24]
1450 CHInline graphic bending C–H deformation [25]
1524 Carotenoids C=C stretching [30]
1656 Amide I C=O stretching, C–N vibration [31]

In Fig. 3, it is evident that several Raman bands exhibit intensity differences across the cancer, precancer, and normal serum groups. Notably, the carotenoid associated peaks at 1006 Inline graphic, 1156 Inline graphic, and 1524 Inline graphic show higher intensities in the normal group compared to precancer and cancer patients, reflecting a depletion of carotenoids during disease progression. Similarly, the collagen-associated band at 1244 Inline graphic (Amide III) demonstrates reduced intensity in cancer and precancer sera relative to normal controls, suggesting structural alterations in serum proteins. Conversely, bands at 1450 Inline graphic (CHInline graphicbending vibration) and 1655 Inline graphic (Amide I), which are primarily linked to lipids and proteins, display relatively stronger signals in cancer patients, indicating biochemical changes in lipid and protein composition during cancer transformation. Smaller differences can also be observed at 753 Inline graphic, 963 Inline graphic, 1309 Inline graphic, and 1343 Inline graphic, further reflecting disease-associated perturbations in nucleic acids, proteins, and lipids. Overall, the spectral variations across these diagnostic bands highlight biochemical differences between cancer, precancer, and normal groups, particularly involving carotenoids, lipids, and proteins, which can serve as potential biomarkers for oral cancer detection.

Fig. 3.

Fig. 3

Average ± standard deviation (SD) value of Raman intensity of bands observed in different class of serum samples

Classification performance

The training and testing curves indicate stable learning behavior of the proposed 1D-CNN model over 10 epochs. The model was trained for 10 epochs because both the accuracy and loss curves showed rapid convergence during the early training stage, while performance stabilized in the later epochs. Extending training beyond this point was unlikely to provide substantial improvement and could increase the risk of overfitting due to the limited dataset size.

For the augmented model, the mean training accuracy increased from approximately 40% to 85–90%, while the mean testing accuracy improved from around 30% to 75–76% [Fig. 4(a)]. Similarly, the mean training and testing loss values decreased from about 2.0 to below 0.5 and 0.7, respectively [Fig. 4(b)]. These trends indicate progressive convergence without severe divergence between training and testing performance. For the non-augmented model, both training and testing accuracy also increased steadily, while the corresponding loss values decreased across epochs [Figs. 4 (c) and 4(d)]. By the final epochs, the testing accuracy reached approximately 82–85%, and the testing loss decreased to around 0.60, suggesting stable learning and good generalization. Compared with the augmented model, the non-augmented model achieved better final testing performance, indicating that augmentation improved training smoothness but did not provide additional generalization benefit under the present experimental setting.

Fig. 4.

Fig. 4

Performance metrics of the proposed 1D-CNN model: a accuracy and b loss with data augmentation; c accuracy and d loss without data augmentation. Results represent the mean and SD (error bars) over five repeated runs

Tables 4 and 5 summarize the classification performance of the augmented and non-augmented models, respectively. In the non-augmented model, the normal class showed the strongest overall performance, with precision, recall, and F1-score values of Inline graphic, Inline graphic, and Inline graphic, respectively. The cancer class also demonstrated strong discrimination, with precision, recall, and F1-score values of Inline graphic, Inline graphic, and Inline graphic. In contrast, the precancer class remained the most challenging category, showing comparatively lower recall Inline graphic and F1-score Inline graphic, likely due to partial spectral overlap with both normal and cancer groups. Specifically, the final selected non-augmented model improved the augmented model by 7.9%, 8.2%, and 7.3% in terms of macro-F1, macro-precision, and macro-recall, respectively, while the overall accuracy increased by 6.3%. Overall, these updated results confirm that the non-augmented model outperformed the augmented configuration and was therefore selected as the final model for the independent validation of the model.    

Table 4.

Comprehensive classification performance metrics of the proposed 1D-CNN model trained with data augmentation, including per-class results and global averaged measures

Metric / Class Precision Recall F1-score
Cancer Inline graphic   Inline graphic   Inline graphic          
Precancer Inline graphic   Inline graphic   Inline graphic          
Normal Inline graphic   Inline graphic   Inline graphic  
Global Metrics Value Metric Value
Accuracy Inline graphic   Macro-Precision Inline graphic  
Macro-Recall Inline graphic   Macro-F1 Inline graphic  
Weighted-F1 Inline graphic  

Table 5.

Comprehensive classification performance metrics of the proposed 1D-CNN model trained without data augmentation, including per-class results and global averaged measures

Metric /Class Precision Recall F1-score
Cancer Inline graphic   Inline graphic       Inline graphic  
Precancer Inline graphic   Inline graphic   Inline graphic  
Normal Inline graphic   Inline graphic   Inline graphic  
Global Metrics Value Metric Value
Accuracy Inline graphic   Macro-Precision Inline graphic  
Macro-Recall Inline graphic   Macro-F1 Inline graphic      
Weighted-F1 Inline graphic  

Independent validation results

To further validate the robustness of the model, an independent test cohort was subsequently obtained from Chang Gung Memorial Hospital, Taiwan. This specific dataset was collected and analyzed at a later stage, separate from the initial training and testing phases, to ensure the model’s predictive performance remains consistent across different temporal sampling points. The independent test cohort consisted of 6 newly recruited subjects, including 2 cancer, 2 precancer, and 2 normal cases. Detailed demographic information, including age and sex, is provided in Table 6. The inclusion of demographic information improves the clinical interpretability of the independent evaluation cohort. The independent test results reported here correspond to the final selected 1D-CNN model trained without data augmentation, since this configuration yielded better overall classification performance than the augmented model. Overall, the model assigned relatively high probabilities to the correct classes for most samples. For example, cancer cases were correctly classified with cancer probabilities of 0.88 and 0.93, indicating strong model confidence. Normal samples were also identified reliably, with predicted probabilities exceeding 0.78 for the normal class. In comparison, precancerous samples showed lower classification confidence. One precancer case was misclassified as cancer with a probability of 0.66, whereas another was correctly classified as precancer with a probability of 0.73. These findings suggest that the model maintained reasonable generalization on unseen patient samples, while the main source of ambiguity remained the boundary between precancer and cancer. This trend is consistent with the partial spectral overlap observed during internal testing. However, these findings should be interpreted as preliminary because of the limited size of the independent cohort.

Table 6.

The independent test results reported here correspond to the final selected 1D-CNN model trained without data augmentation, since this configuration yielded better overall classification performance than the augmented model

Sample ID True Class Age(Years), Gender Probability Probability Probability Correct
(Cancer) (Precancer) (Normal) correctly classified
P1 Cancer 55,M 0.8827 0.1067 0.0106 Yes
P2 Precancer 60,M 0.6554 0.2125 0.1321 No
P3 Normal 58,M 0.0923 0.0545 0.8532 Yes
P4 Cancer 59,M 0.9335 0.0258 0.0407 Yes
P5 Precancer 54,M 0.2532 0.7310 0.0158 Yes
P6 Normal 70,F 0.0092 0.2074 0.7834 Yes

The proposed 1D-CNN effectively distinguished normal, precancer, and cancer serum spectra, demonstrating stable multi-class classification performance. Across repeated runs, the final selected non-augmented model achieved an overall accuracy of Inline graphic, with macro-precision, macro-recall, and macro-F1 values of Inline graphic, Inline graphic, and Inline graphic, respectively. These results indicate balanced discrimination across the three diagnostic groups, although the precancer class remained relatively more challenging, likely due to partial spectral overlap with both normal and cancer spectra. Overall, the findings confirm that the proposed deep learning framework was able to capture subtle biochemical variations in serum Raman spectra associated with progressive malignant transformation. Data augmentation using jittering, scaling, and spectral shifting was additionally evaluated as a comparative strategy because such approaches are widely used in spectroscopy to increase training diversity and reduce overfitting under limited-data conditions [32, 33]. However, under the present experimental setting, the non-augmented model outperformed the augmented model, suggesting that the synthetic perturbations introduced by augmentation did not provide additional generalization benefit for this dataset. This may reflect the fact that class-weighted learning alone was sufficient to address class imbalance, while the introduced spectral variability may have partially weakened subtle class-discriminative Raman patterns. This is consistent with previous spectroscopy studies showing that augmentation-based or imbalance-handling strategies do not always yield statistically significant improvement, particularly when class similarity is high or the generated variability is not sufficiently representative of the underlying spectral distribution [34]. Although conventional chemometric methods such as PLS-DA and PCA-DA remain competitive [35, 36] and interpretable for Raman classification, particularly on relatively small datasets, the proposed 1D-CNN was explored here to capture broader multivariate and potentially nonlinear spectral relationships in an end-to-end manner [37, 38]. In this context, the CNN was employed to model full-spectrum biochemical variation that may not be fully represented by isolated peak-wise analysis alone.    

The comparative stability and reproducibility of serum as a diagnostic biofluid further strengthened the reliability of Raman-based classification. Serum was selected as the analytical biofluid because it provides a clinically relevant matrix for detecting systemic biochemical changes, while being less influenced by local oral-environment factors than saliva [39]. The observed spectral distinctions, particularly in the amide, CH-bending, and (1300–1350 cm Inline graphic), egions, are consistent with reported Raman changes associated with alterations in proteins, lipids, and nucleic-acid-related components during malignant transformation [40, 41]. Additionally, validation using a temporally separated dataset—collected from new patients under identical acquisition protocols—confirmed the model’s applicability to real-world clinical scenarios. The consistent accuracy obtained from this independent validation supports the generalizability and reliability of the proposed approach. Overall, the study demonstrates that coupling Raman spectroscopy with a tailored 1D-CNN framework can provide a non-invasive, rapid, and reproducible diagnostic tool for early detection and classification of oral cancer. The model’s interpretability, balanced class performance, and robustness to data variability establish a strong foundation for future large-scale clinical translation and cross-site validation.

A limitation of the present study is the relatively small number of analyzed patients, which may restrict the statistical power and generalizability of the findings. Although this work represents a proof-of-concept study demonstrating the feasibility of serum Raman spectroscopy combined with 1D-CNN analysis for three-class oral lesion classification. The results are encouraging, the limited sample size and single-center design mean that broader clinical applicability should be interpreted cautiously and requires validation in larger multi-center cohorts.

Conclusion

The proposed 1D-CNN model demonstrated the feasibility of classifying serum Raman spectra into normal, precancer, and cancer groups. The final selected non-augmented model achieved an overall accuracy of 83%, with macro-precision, macro-recall, and macro-F1 values of 85%, 84%, and 83%, respectively, indicating balanced three-class performance. Consistent results on the independent test cohort further supported the generalizability of the framework within the same clinical environment. These findings highlight the promise of combining serum Raman spectroscopy with deep learning as a non-invasive strategy for oral cancer-related classification, although larger multi-center studies are still needed for broader clinical validation.

Acknowledgements

The author would like to thank Dr. Shiang-Fu Huang from Chang Gung Memorial Hospital and their team for assisting us to prepare the serum samples.

Author contributions

Mukta Sharma: Writing – original draft, Validation, Methodology, Data curation, Conceptualization, Software and Formal analysis and Shiang-Fu Huang: Writing – review & editing, Supervision, Resources.

Funding

This work was partially supported by Grant NSTC 113–2222-E-167–003 -MY2 from the National Science and Technology Council (Taiwan).

Data availability

Data will be made available from the corresponding author upon request.

Declarations

Ethical approval and consent to participate

This study was performed in line with the principles of the Declaration of Helsinki. Ethical approval was granted by the Institutional Review Board of the Chang Gung Medical Foundation, Taiwan (IRB Nos. 202300682B0 and 201800439B0). Written informed consent was obtained from all participants included in the study.

Consent for publication

Written informed consent was obtained from all participants for the publication of their clinical data. All patient information was systematically deidentified prior to analysis to ensure confidentiality.

Competing interests

The authors declare no competing interests.

Footnotes

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

References

  • 1.Kavyashree C, Vimala HS, Shreyas J. A systematic review of artificial intelligence techniques for oral cancer detection. Healthcare Anal. 2024;5:100304. [Google Scholar]
  • 2.Organization WH. Comprehensive assessment of evidence on oral cancer prevention released; 2024.
  • 3.Ribeiro MFA, Oliveira MCM, Leite AC, Bruzinga FFB, Mendes PA, Grossmann SDMC, et al. Assessment of screening programs as a strategy for early detection of oral cancer: a systematic review. Oral Oncol. 2022;130:105936. [DOI] [PubMed] [Google Scholar]
  • 4.Tang J-W, Yuan Q, Zhang L, Marshall BJ, Tay ACY, Wang L. Application of machine learning-assisted surface-enhanced Raman spectroscopy in medical laboratories: principles, opportunities, and challenges. TrAC, Trends Anal Chem. 2025;184:118135. [Google Scholar]
  • 5.Bratchenko LA, Khristoforova YA, Pimenova IA, Tupikova EN, Skuratova MA, Dvoynikov-Sechnoy GA, et al. Sers-based technique for accessible and rapid diagnosis of multiple myeloma in blood serum analysis. Light Adv Manufact. 2025;6:1–11. [Google Scholar]
  • 6.Félix-Rivera H, Hernández-Rivera SP. Raman spectroscopy techniques for the detection of biological samples in suspensions and as aerosol particles: a review. Sensing Imag Int J. 2012;13(1):1–25. [Google Scholar]
  • 7.Sharma M, Kumar A, Tsai C-L, Huang S-F, Hsieh Y-L, Chang L-B. Comparative assessment of serum dilution and pure samples for Raman-based oral cancer detection: evaluating dilution rate performance. Vib Spectrosc. 2025;12:103858. [Google Scholar]
  • 8.Sharma M, Tsai C-L, Arularasu M, Huang S-F, Hsieh Y-L, Chang L-B. Combined feature-based classification of premalignant and malignant oral lesions using velscope endogenous fluorescence imaging and dry serum raman spectroscopy. Photodiagn Photodyn Ther. 2025;24:105247. [DOI] [PubMed] [Google Scholar]
  • 9.Li L, Yu M, Li X, Ma X, Zhu L, Zhang T. A deep learning method for multi-task intelligent detection of oral cancer based on optical fiber Raman spectroscopy. Anal Methods. 2024;16(11):1659–73. [DOI] [PubMed] [Google Scholar]
  • 10.Dadhich M, Prabhu V, Pai V, Harish S, Jose M, et al. Serum and salivary sialic acid as a biomarker in oral potentially malignant disorders and oral cancer. Indian J Cancer. 2014;51(3):214–8. [DOI] [PubMed] [Google Scholar]
  • 11.Wang N, Chen Y, Lin J, Lin Y, Song H, Huang W, et al. Identification of novel serum lipid metabolism potential markers and metabolic pathways for oral cancer: a population-based study. BMC Cancer. 2025;25(1):177. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Bonifacio A, Dalla Marta S, Spizzo R, Cervo S, Steffan A, Colombatti A, et al. Surface-enhanced Raman spectroscopy of blood plasma and serum using ag and au nanoparticles: a systematic study. Anal Bioanal Chem. 2014;406(9):2355–65. [DOI] [PubMed] [Google Scholar]
  • 13.Halder A, Jadhav PA, Maitra A, Banerjee A, Hole A, Epari S, et al. Serum metabolomics profiling coupled with machine learning identifies potential diagnostic and prognostic candidate markers in meningioma using raman spectroscopy, atr-ftir, and lc-ms/ms. J Proteome Res. 2025;24(3):1180–96. [DOI] [PubMed] [Google Scholar]
  • 14.Dong W, Qin M, Wu S, Hu L, Rao C, Du Z. Deep learning-assisted Raman spectroscopy for automated identification of specific minerals. Spectrochim Acta Part A Mol Biomol Spectrosc. 2025;333:125843. [DOI] [PubMed] [Google Scholar]
  • 15.Ebert-Uphoff I, Samarasinghe S, Barnes E. Thoughtfully using artificial intelligence in earth science. Eos. 2019;12:100. [Google Scholar]
  • 16.Luo R, Popp J, Bocklitz T. Deep learning for Raman spectroscopy: a review. Analytica. 2022;3(3):287–301. [Google Scholar]
  • 17.Zhou Y, Tang X, Zhang D, Lee HJ. Machine learning empowered coherent Raman imaging and analysis for biomedical applications. Commun Eng. 2025;4(1):8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Wu M, Wang S, Pan S, Terentis AC, Strasswimmer J, Zhu X. Deep learning data augmentation for Raman spectroscopy cancer tissue classification. Sci Rep. 2021;11(1):23842. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Pavlou E, Kourkoumelis N. Deep adversarial data augmentation for biomedical spectroscopy: application to modelling Raman spectra of bone. Chemom Intell Lab Syst. 2022;228:104634. [Google Scholar]
  • 20.Sakai A, Minoda Y, Morikawa K. Data augmentation methods for machine-learning-based classification of bio-signals. In: 2017 10th Biomedical Engineering International Conference (BMEiCON) 2017. pp. 1–4. IEEE.
  • 21.Flanagan AR, Dalal D, Glavin FG. Exploring generative artificial intelligence and data augmentation techniques for spectroscopy analysis. Chem Rev. 2025;125(13):6130–55. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Jeng M-J, Sharma M, Sharma L, Chao T-Y, Huang S-F, Chang L-B, et al. Raman spectroscopy analysis for optical diagnosis of oral cancer detection. J Clin Med. 2019;8(9):1313. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Grandini M, Bagli E, Visani G. Metrics for multi-class classification: an overview. .arXiv preprint arXiv:2008.05756; 2020.
  • 24.Hernández B, Coïc Y-M, Kruglik SG, Sanchez-Cortes S, Ghomi M. Relationships between conformational and vibrational features of tryptophan characteristic Raman markers. Spectrochim Acta Part A Mol Biomol Spectrosc. 2024;316:124377. [DOI] [PubMed] [Google Scholar]
  • 25.Sharma M, Li Y-C, Manjunatha S, Tsai C-L, Lin R-M, Huang S-F, et al. Identification of healthy tissue from malignant tissue in surgical margin using Raman spectroscopy in oral cancer surgeries. Biomedicines. 2023;11(7):1984. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Adar F. Interpretation of Raman spectrum of proteins; 2022.
  • 27.John RV, Devasia TN, Lukose M, Chidangil JS. Micro-Raman spectroscopy study of blood samples from myocardial infarction patients. Lasers Med Sci. 2022;37(9):3451–60. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 28.De Gelder J, De Gussem K, Vandenabeele P, Moens L. Reference database of Raman spectra of biological molecules. J Raman Spectroscopy Int J Original Work in all Aspects of Raman Spectroscopy Including Higher Order Processes and also Brillouin Rayleigh Scatter. 2007;38(9):1133–47. [Google Scholar]
  • 29.Pezzotti G, Zhu W, Terai Y, Marin E, Boschetto F, Kawamoto K, et al. Raman spectroscopic insight into osteoarthritic cartilage regeneration by mRNA therapeutics encoding cartilage-anabolic transcription factor runx1. Materials Today Bio. 2022;13:100210. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Ermakov IV, Sharifzadeh M, Ermakova M, Gellermann W. Resonance Raman detection of carotenoid antioxidants in living human tissue. J Biomed Opt. 2005;10(6):064028–064028. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Williams AE, Hammer NI, Fortenberry RC, Reinemann DN. Tracking the amide i and coo- terminal (c= o) Raman bands in a family of l-glutamic acid-containing peptide fragments: A raman and dft study. Molecules. 2021;26(16):4790. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Flanagan AR, Glavin FG. A comparative analysis of data synthesis techniques to improve classification accuracy of Raman spectroscopy data. J Chem Inf Model. 2023;64(7):2311–22. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Gracia Moisés A, Vitoria Pascual I, Imas González JJ, Ruiz Zamarreño C. Data augmentation techniques for machine learning applied to optical spectroscopy datasets in agrifood applications: a comprehensive review. Sensors. 2023;23(20):8562. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Chung J, Zhang J, Saimon AI, Liu Y, Johnson BN, Kong Z. Imbalanced spectral data analysis using data augmentation based on the generative adversarial network. Sci Rep. 2024;14(1):13230. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Al-Sammarraie SZ, Bratchenko LA, Tupikova EN, Skuratova MA, Wang S, Lebedev PA, et al. Human blood plasma sers analysis using silver nanoparticles for cardiovascular diseases detection. J Biomed Photonics Eng. 2024;10(1):4–12. [Google Scholar]
  • 36.Baker MJ, Trevisan J, Bassan P, Bhargava R, Butler HJ, Dorling KM, et al. Using fourier transform ir spectroscopy to analyze biological materials. Nat Protoc. 2014;9(8):1771–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Kazemzadeh M, Hisey CL, Zargar-Shoshtari K, Xu W, Broderick NG. Deep convolutional neural networks as a unified solution for Raman spectroscopy-based classification in biomedical applications. Optics Commun. 2022;510:127977. [Google Scholar]
  • 38.Fuentes AM, Narayan A, Milligan K, Lum JJ, Brolo AG, Andrews JL, et al. Raman spectroscopy and convolutional neural networks for monitoring biochemical radiation response in breast tumour xenografts. Sci Rep. 2023;13(1):1530. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.d’Amone L, Matzeu G, Omenetto FG. Stabilization of salivary biomarkers. ACS Biomaterials Sci Eng. 2021;7(12):5451–73. [DOI] [PubMed] [Google Scholar]
  • 40.Auner GW, Koya SK, Huang C, Broadbent B, Trexler M, Auner Z, et al. Applications of raman spectroscopy in cancer diagnosis. Cancer Metastasis Rev. 2018;37(4):691–717. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Elumalai S, Managó S, De Luca AC. Raman microscopy: progress in research on cancer cell sensing. Sensors. 2020;20(19):5525. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Data will be made available from the corresponding author upon request.


Articles from Discover Oncology are provided here courtesy of Springer