Wearable Electrical Impedance Myography for Continuous, Non-Invasive Detection of Acute Compartment Syndrome: A Preclinical Feasibility Study

Mohammad Javad Shariyate, Mohammad Khak, Buket Sonbas-Cobb, Maria V Velasquez Hammerle, Baoguo Wei, Sara Robicheau, Kirsten Dunlap, Ahmad Hedayatzadeh Razavi, Mario Keko, Seward Rutkove, Ara Nazarian
PMCID: PMC13370570  PMID: 42465943

Abstract

Introduction: Acute compartment syndrome (ACS) is a limb-threatening complication of extremity trauma that requires timely diagnosis to prevent irreversible muscle and nerve injury. Current diagnostic methods are invasive, intermittent, and operator-dependent. We evaluated the feasibility of a novel, Bluetooth-enabled electrical impedance myography (EIM) device (mAlert, Myolex, Inc., Brookline, MA, USA) for continuous, noninvasive detection of ACS-related tissue changes. Methods: Ten Yorkshire swine underwent anterior tibial compartment monitoring using three ACS models: albumin infusion (ALB, n=3), femoral artery and vein ligation (LIG, n=3), and combined albumin infusion plus ligation (ALB+LIG, n=4). Resistance (R), reactance (X), and phase (P) were measured every minute across 1 to 199 kHz alongside continuous intra-compartmental pressure (ICP) monitoring. Group differences in normalized impedance trends were evaluated using the Kruskal Wallis test with Dunn post hoc correction. As a proof-of-concept human study, nine healthy volunteers wore the device for up to five days to assess electrode durability and signal stability. Tissue ischemia was validated using pimonidazole immunohistochemistry. Results: ALB infusion produced progressive, frequency-dependent decreases in R, X, and P, whereas LIG produced consistent increases in R and X across frequencies. The ALB+LIG model generated mixed responses, reflecting the competing effects of edema and ischemia. Normalized phase slopes differed significantly among groups (H=6.14, p=0.046), with post hoc testing showing significant divergence between the ALB and LIG models (p=0.041). Control limbs remained stable throughout monitoring. Pimonidazole staining confirmed hypoxic injury in the intervention limb. In the human pilot study, three participants completed five days of monitoring, demonstrating sustained signal acquisition, while electrode degradation limited data collection in the remaining participants. Conclusions: This preliminary feasibility study demonstrates that wearable EIM can continuously detect model-specific physiological changes associated with ACS in a large-animal model. These findings support further development and clinical evaluation of wearable EIM as a non-invasive monitoring technology for early ACS detection in trauma patients.

Full Text Availability

The license terms selected by the author(s) for this preprint version do not permit archiving in PMC. The full text is available from the preprint server.


Articles from medRxiv are provided here courtesy of Cold Spring Harbor Laboratory Preprints

RESOURCES