Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2026 Apr 16;138(2):196–207. doi: 10.1111/bju.70270

Micro‐ultrasonography‐ vs MRI‐targeted biopsy in prostate cancer: Updated systematic review and meta‐analysis

José Pedro Cassemiro Micheleto 1, Tallys Ávila Suzuki 1, Lucas Amorim Santos 1, Luann Porpino Sales 1, Roberto Iglesias Lopes 1, Bárbara Miranda Martins 1, Bárbara Vieira Lima Aguiar Melão 2, Mauricio Dener Cordeiro 1, Walid Sharour 3, Walid Shabana 3, William Carlos Nahas 1, Leopoldo Alves Ribeiro Filho 1, Caio Vinicius Suartz 3,✉
PMCID: PMC13371815  PMID: 41989063

Abstract

Objective

To refine prostate cancer (PCa) pathways by comparing micro‐ultrasonography‐targeted biopsy (micro‐US‐TBx) with magnetic resonance imaging (MRI)‐TBx for detecting clinically significant PCa (csPCa) and by evaluating diagnostic accuracy (sensitivity, specificity, positive predictive value, negative predictive value).

Methods

The Medical Literature Analysis and Retrieval System Online (MEDLINE; PubMed), Excerpta Medica dataBASE (EMBASE), and ClinicalTrials.gov were searched on 4 July 2025 and updated 5 August 2025, without language/date limits. Eligible randomised and observational studies compared micro‐US‐TBx vs MRI‐TBx (± systematic biopsy) in men with suspected PCa or on active surveillance; csPCa was Gleason Grade Group ≥2. Two reviewers screened/extracted per the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses 2020 guidelines; quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies‐2 tool. Detection ratios (DRs) were pooled with random‐effects models; diagnostic accuracy used a bivariate random‐effects model from 2 × 2 tables. Certainty of evidence was rated with the Grading of Recommendations, Assessment, Development, and Evaluation framework.

Results

A total of 22 studies (micro‐US‐TBx = 5581; MRI‐TBx = 5937) were included. Micro‐US‐TBx detected 2037 csPCa cases and MRI‐TBx 2043. The pooled DR (micro‐US‐TBx vs MRI‐TBx) was 1.04 (95% confidence interval 0.95–1.15; I 2 = 61.1%). Pooled sensitivity/specificity were 0.88/0.25 for micro‐US‐TBx and 0.81/0.17 for MRI‐TBx. Summary receiver operating characteristic curves overlapped (area under the curve: micro‐US, 0.658; MRI, 0.547). Meta‐regression found no significant modality effect on sensitivity (P = 0.192) or specificity (P = 0.257). Egger's test indicated no meaningful publication bias (P = 0.848).

Conclusion

The micro‐US‐TBx demonstrated csPCa detection and diagnostic accuracy comparable to MRI‐TBx. Given its real‐time imaging capability, accessibility, and potential workflow advantages, micro‐US‐TBx may represent a valuable complementary tool within contemporary PCa diagnostic pathways. Further cost‐effectiveness studies are warranted to better define its role in clinical practice.

Keywords: meta‐analysis, systematic review, micro‐ultrasound, magnetic resonance imaging, prostate cancer


Abbreviations

bpMRI

biparametric MRI

DR

detection ratio

GG

Grade Group

GRADE

Grading of Recommendations, Assessment, Development, and Evaluation; micro‐US, micro‐ultrasonography

mpMRI

multiparametric MRI

(cs)(ci)PCa

(clinically significant) (clinically insignificant) prostate cancer

PRI‐MUS

Prostate Risk Identification using Micro‐US

(N)(P)PV

(negative) (positive) predictive value

PRISMA

Preferred Reporting Items for Systematic Reviews and Meta‐Analyses

QUADAS‐2

Quality Assessment of Diagnostic Accuracy Studies‐2

RCT

randomised controlled trial

SBx

systematic biopsy

SROC

summary receiver operating characteristic

TBx

targeted biopsy

Introduction

Prostate cancer (PCa) affects millions of men worldwide each year. In high‐income regions, it is among the most prevalent solid malignancies, with prognosis varying according to age, ethnicity, genetic background, and disease stage [1, 2]. Clinical suspicion of PCa arises primarily from elevated PSA levels and/or abnormal DRE findings [3]; and is generally categorised into clinically significant PCa (csPCa), which requires curative interventions such as radical prostatectomy, and clinically insignificant PCa (ciPCa), which is typically managed with active surveillance guided by PSA monitoring [4]. In this context, there remains an unmet clinical need for diagnostic strategies that reliably detect csPCa while reducing overdiagnosis of indolent disease and avoiding unnecessary biopsies [5].

Multiparametric MRI (mpMRI) is a resource‐intensive diagnostic modality, which restricts its availability primarily to large centres. Nevertheless, it is widely used and demonstrates high sensitivity (86–92%) and specificity (60–83%) for detecting index lesions in PCa [6]. Current guidelines from the AUA [5] and the European Association of Urology [7] recommend TRUS‐guided biopsy as the standard approach for histological confirmation of PCa. When a suspicious lesion is identified on mpMRI, targeted prostate biopsy should be performed using either software‐based fusion of mpMRI with real‐time ultrasonography (US) images or cognitive targeting [8].

To address some of the limitations of mpMRI, a novel, low‐cost, high‐resolution US technology—micro‐US (micro‐US; ExactVu, Exact Imaging, Markham, Ontario, Canada)—has been developed. Operating at 29 MHz, substantially higher than conventional TRUS frequencies, micro‐US provides real‐time, high‐resolution imaging that enables direct visualisation of suspicious tissue. This capability holds promise for reducing reliance on pre‐biopsy MRI [9]. Lesions detected on micro‐US are scored using the Prostate Risk Identification using Micro‐US (PRI‐MUS) system, in which scores of 1–2 indicate low risk, 3 is equivocal, and 4–5 are considered highly suspicious for PCa [10].

The recently published OPTIMUM trial (ClinicalTrials.gov identifier: NCT05220501) [11], a large international randomised clinical study involving 678 men undergoing biopsy, demonstrated that micro‐US‐guided biopsy is non‐inferior to MRI‐fusion‐guided biopsy for the detection of csPCa.

Given the growing body of evidence supporting the integration of micro‐US into the diagnostic pathway for suspected csPCa, we conducted a systematic review of observational and randomised controlled trials (RCTs). We specifically compared micro‐US‐targeted biopsy (micro‐US‐TBx) with MRI‐TBx in terms of csPCa detection. The primary outcome was the detection rate of csPCa, while secondary outcomes included pooled diagnostic accuracy metrics (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]).

The aim of this review was to compare the detection rate of csPCa between micro‐US‐TBx and MRI–TBx, and to pool diagnostic accuracy metrics.

Methods

Protocol Registration

This systematic review and meta‐analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses (PRISMA) 2020 guidelines [12]. Thus, our systematic review was registered with the International Prospective Register of Systematic Reviews (PROSPERO) on 25 September 2025 (registration number CRD420251155775) [13].

Eligibility Criteria

We included observational studies and RCTs that compared the detection of csPCa, defined as Gleason Grade Group (GG) ≥2, in men with suspected PCa or those under active surveillance. Eligible studies evaluated outcomes from micro‐US‐guided biopsy vs MRI/conventional US‐guided biopsy. Clinical suspicion of PCa was defined as elevated PSA levels, abnormal DRE findings, and/or suspicious lesions on mpMRI. Additional eligibility criteria required the absence of contraindications to MRI or prostate biopsy, as well as the absence of a prior prostate MRI.

Information Sources

We systematically searched MEDLINE (PubMed), Excerpta Medica dataBASE (EMBASE), and ClinicalTrials.gov on 4 July 2025, and updated the search on 5 August 2025 (Fig. S1), with no language or publication date restrictions. Using both keywords and controlled vocabulary (Medical Subject Headings [MeSH]/Emtree), the core string was: (‘prostate cancer’ OR ‘prostate neoplasm’ OR ‘prostatic neoplasm’ OR ‘prostate adenocarcinoma’) AND (‘micro‐ultrasound’ OR ‘micro‐ultrasonography’ OR ‘micro ultrasound’ OR ‘micro‐ultrasound‐guided’ OR ‘micro‐US’) AND (‘magnetic resonance imaging’ OR ‘MRI’ OR ‘MR imaging’). Full database‐specific strategies are provided in the Appendix S1.

Selection Process

Two authors (J.M. and T.A.) independently selected the studies. In cases of disagreement between the two reviewers, a third author (C.S.) resolved discrepancies by consensus. For duplicate studies and multiple reports from the same cohort, we examined only (a) the largest cohort, (b) the one with the longest follow‐up, or (c) the most recent report.

Data Collection

Two authors (J.M. and T.A.) independently screened studies in three stages: (a) title review, (b) abstract review, and (c) full‐text assessment. Reference lists of eligible articles were also examined to identify additional relevant studies (snowballing/citation chaining). Disagreements between the two reviewers were resolved by consensus with a third author (L.S.). Literature screening and coding were managed using Rayyan software [14].

Data Items

Data were extracted into a piloted spreadsheet using Microsoft Excel 2019 (Microsoft Corporation, Redmond, WA, USA). The following information was collected: first author's name, article title, journal, year of publication, study design, type of guided biopsy, number of participants, study objectives, inclusion criteria, and variables related to PCa outcomes and technical characteristics. When relevant information was missing, attempts were made to contact the corresponding authors via e‐mail to obtain additional details.

Effect Measures

We investigated the main outcome by analysing detection risk measures and their corresponding 95% CIs for variables associated with the detection of csPCa. Accuracy measures, including sensitivity, specificity, PPV, and NPV, were also assessed.

Synthesis Methods

The meta‐analysis was independently conducted by two reviewers (J.M. and T.A.) using R version 4.3.2 (The R Foundation for Statistical Computing, Vienna, Austria) [15]. Discrepancies between their analyses were resolved through consensus with a third reviewer (C.S.).

Heterogeneity was assessed using Cochran's Q test [16] and the Higgins and Thompson I 2 statistic [17]. A P < 0.05 was considered statistically significant for Cochran's Q test. I 2 values were interpreted as follows: 0–<25% indicated negligible heterogeneity, 25–<40% moderate heterogeneity, and ≥40% substantial heterogeneity.

Micro‐US‐TBx was considered the index test, with MRI‐TBx as the comparator (reference standard). The index test produced binary outcomes (presence or absence of csPCa) at the patient level. Data were organised into 2 × 2 contingency tables to calculate sensitivity and specificity for each included study. Study‐level results were presented as forest plots and summary receiver operating characteristic (SROC) curves.

Summary estimates of sensitivity and specificity were obtained using a bivariate random‐effects model, with 95% CIs derived from the model along with pooled estimates. To further explore heterogeneity, a bivariate model with covariates was also applied.

Study Methodological Quality Assessment

We assessed the risk of bias and applicability concerns for each study using the Quality Assessment of Diagnostic Accuracy Studies‐2 (QUADAS‐2) tool. QUADAS‐2 evaluates four domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed for risk of bias, and the first three domains are also evaluated for applicability concerns [18]. Quality assessment was independently performed by two authors (L.A., B.M.), with disagreements resolved by a third reviewer (J.M.). In addition, we evaluated risk of bias across studies (publication bias) through visual inspection of contour‐enhanced funnel plot asymmetry and the Egger test [19].

Grading of Evidence, Data Synthesis and Statistical Analysis

We assessed the certainty of the evidence for csPCa detection rates and diagnostic accuracy (sensitivity, specificity, PPV, and NPV) comparing micro‐US‐TBx and MRI‐TBx using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) framework. Two reviewers (J.M., T.S.) independently rated the GRADE domains—risk of bias, inconsistency, indirectness, imprecision, and publication bias—with disagreements resolved by consensus (Fig. S4). For each modality, the detection rate was defined as the proportion of participants diagnosed with the relevant Gleason GG of PCa among those who underwent that biopsy approach (in head‐to‐head studies, denominators corresponded to the number evaluated by each modality).

Classification of outcomes (true positives, false positives, true negatives, and false negatives) used to calculate diagnostic—and, where applicable, staging—accuracy was based on histopathological findings from prostate biopsy as the reference standard. Pooled sensitivity and specificity estimates, and hierarchical SROC curves were generated in R (version 4.5.1; R Foundation for Statistical Computing) using the ‘meta’ and ‘mada’ packages [20, 21]. Between‐study heterogeneity was quantified using the I 2 statistic and assessed with Cochran's Q test. I 2 was categorised as low (<25%), moderate (25–50%), or high (≥50%). Statistical significance was set at P < 0.05. All analyses were conducted in R (version 4.5.1; R Foundation for Statistical Computing).

Results

Study Selection

The literature search identified 283 records. After the removal of 114 duplicates, 169 records were screened by title and abstract. Of these, 140 were excluded for not meeting the study objectives. The full texts of the remaining 30 articles were assessed for eligibility, and 22 studies were ultimately included in the final analysis [11, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42]. The detailed study selection process is illustrated in the PRISMA flow diagram in Fig. S1. Of these, one was a RCT [11], while 21 were observational studies, comprising 10 retrospective and 11 prospective designs [22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42].

Study and Population Characteristics

Overall, 22 studies published between 2019 and 2025 were included, comprising 5581 patients who underwent micro‐US‐TBx and 5937 who underwent MRI‐TBx (Fig. S1) [11, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42]. The median (range) age was 66 (59–74) years, median (range) PSA level was 7.1 (5.39–11) ng/mL, and median (range) prostate volume was 50 (37–61.34) mL. Most patients were re‐biopsy (n = 5204), while 2909 were biopsy naïve. All had suspected csPCa, with 2037 cases detected by micro‐US‐TBx and 2043 by MRI‐TBx. Baseline characteristics are presented in Table 1 [11, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42], and the oncological characteristics of the included studies are summarised in Table 2. None of the included studies enrolled patients with a prior diagnosis of csPCa.

Table 1.

Study characteristics.

Study (n = 22) Study period Type of study Compared techniques Criteria for biopsy indication No. patients Age, years
Abouassaly et al., 2020 [22] 01/2018–08/2018 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Patients underwent prostate biopsy 67 66 (IQR 59–69)
Albers et al., 2024 [23] 09/2021–07/2023 Retrospective, single centre Micro‐US‐TBx vs MRI‐TRUS Biopsy‐naive patients with clinical suspicion of prostate cancer who underwent a prostate biopsy with negative MRI 103 61.7 (SD 7.4)
Avolio et al., 2025 [24] 10/2017–04/2024 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx Elevated PSA levels, abnormal DRE, and/or MRI findings at least 1 PI‐RADS ≥3 1423 65 (IQR 59–72)
Beatrici et al., 2024 [25] 10/2017–02/2023 Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx Clinical examinations and PSA levels 304 66.0 (IQR 61–71)
Claros et al., 2020 [26] 02/2017–09/2018 Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs RBx DRE and PSA values 269 68 (IQR 62–72)
Cornud et al., 2020 [27] 02/2019–07/2019 Prospective, single centre Micro‐US‐TBx vs MRI‐TRUS Elevated or rising PSA level and at least one focal abnormality with a bpMRI score ≥3 118 66 (SD 13)
Dagnino et al., 2024 [28] 10/2017– Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Biopsy naïve men with discordant lesions on micro US and mpMRI imaging, who underwent fusion prostate biopsy within 6 months of mpMRI 178 –
Dias et al., 2023 [29] 01/2021–06/2022 Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Biopsy naïve, a total PSA <20 ng/mL and having a mpMRI performed prior to the micro‐US and biopsy 139 69 (IQR 64–73)
Eure et al., 2019 [30] 12/2016–12/2016 Prospective paired diagnostic Micro‐US‐TBx vs mpMRI‐TBx vs SBx Patients enrolled in the active surveillance program 9 66 (IQR 62–68)
Ghai et al., 2022 [31] 05/2019–09/2020 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx PSA level or abnormal DRE findings and no previous PBx 94 61 (IQR 57–68)
Hofbauer et al., 2022 [32] 01/2019–12/2019 Prospective multicentre Micro‐US‐TBx vs mpMRI‐TBx PSA value and/or suspicious DRE 203 66 (IQR 59–70)
Khajir et al., 2025 [33] 10/2021–01/2023 Retrospective, single centre MRI‐micro‐US‐TBx vs MRI‐conventional US‐TBx vs SBx PI‐RADS ≥2 and biopsy status (biopsy naïve, prior negative, or active surveillance), who underwent MRI‐conventional US fusion biopsy 899 67 (IQR 60–72)
Kinnaird et al., 2025 [11] 12/2021–09/2024 Randomised prospective multicentre Micro‐US‐TBx vs micro‐US/mpMRI‐TBx vs MRI/conventional‐US‐TBx Elevated PSA and/or abnormal DRE findings 802 –
Klotz et al., 2020 [34] 05/2019–09/2020 Multicentre, prospective Micro‐US‐TBx vs mpMRI‐TBx vs SBx Elevated PSA and/or abnormal DRE, with or without a suspicious mpMRI 1040 67 (IQR 61–72)
Lorusso et al., 2022 [35] 11/2018–05/2019 Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs whole mount sections Patients with biopsy confirmed prostate cancer and scheduled for robot‐assisted radical prostatectomy 32 67 (range 52–72)
Lughezzani et al., 2021 [36] 10/2017–09/2019 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Elevated PSA or abnormal DRE and PI‐RADS ≥3 320 65 (IQR 59–70)
Pereira‐Arias et al., 2019 [37] 02/2017–01/2018 Retrospective, single centre Micro‐US vs mpMRI vs SBx Elevated PSA or abnormal DRE 96 67 (SD 5.5)
Piccolini et al., 2024 [38] 10/2017–05/2023 Retrospective, single centre – Propensity score–matched comparison Micro‐US TRBx vs TPBx + mpMRI Elevated PSA, positive DRE, or mpMRI and PI‐RADS ≥3 1423 –
Pickersgill et al., 2025 [39] 02/2021–04/2023 Retrospective, single centre Micro‐US‐TBx vs mpMRI‐TBx Elevated PSA or abnormal DRE. 161 65.6 (SD 1.5)
Rojo et al., 2024 [40] 05/2021–06/2022 Prospective, multicentre Micro‐US‐TBx vs mpMRI‐TBx PSA ≥4 ng/mL and/or abnormal DRE and PI‐RADS ≥3 80 69.1 (SD 9.02)
Socarrás et al., 2020 [41] 02/2018–09/2019 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Elevated PSA or suspicious DRE or PI‐RADS ≥3 in mpMRI 194 62 (IQR 58–68)
Wiemer et al., 2021 [42] 02/2018–12/2018 Prospective, single centre Micro‐US‐TBx vs mpMRI‐TBx vs SBx Clinical risk of PCa 159 70 (IQR 64–74)

PBx, prostate biopsy; RBx, random biopsies; TPBx, transperineal biopsy; TRBx, transrectal biopsy.

Table 2.

Oncologic Characteristics of the Included Studies.

Study (n = 22) Biopsy Naive PSAt (ng/mL) DRE Prostate Volume (cc) PRI‐MUS (%) PIRADS (%)
+ − 1–2 3 4 5 1–2 3 4 5
Abouassaly, 2020 [22] ‐ 5.39 (IQR: 4.1–8.7) 7 44 38 (IQR: 24–50) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Albers, 2024 [23] 103 ‐ 11 92 ‐ 37 (66%) 4 (7%) 3(5%) 12 (21%) 103 (100%) ‐ ‐ ‐
Avolio, 2025 [24] 533 7 (IQR: 5–9) 380 1043 50 (IQR: 36–67) 347 (24%) 147 (10%) 593 (42%) 336 (24%) 247 (17%) 241 (17%) 574 (40%) 361 (25%)
Beatrici, 2024 [25] 8.6 (IQR: 5.8–11.5) 58 206 52.6 (IQR: 49.5–77) 84 (27.6%) 27 (8.9%) 133 (43.8%) 60 (19.7%) 103 (33.9%) 57 (18%) 104 (34.2%) 40 (13.2%)
Claros, 2020 [26] 69 7.8 (IQR: 5.5–10.2) ‐ ‐ 48.5 (IQR: 36–65) 8 (17.4%) 2 (4.3%) 16 (34.8%) 20 (43.5%) ‐ 21 (7.8%) 155 (57.6%) 82 (30.5%)
Cornud, 2020 [27] 79 11 (SD ± 19) 16 102 53 (SD: ± 26) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Dagnino, 2024 [28] 178 ‐ 21 92 ‐ ‐ 31 (17.4%) 119 (66.9%) 28 (15.7%) 26 (14.6%) 36 (20,2%) 96 (54%) 20 (11.2%)
Dias, 2023 [29] 139 7.5 (IQR: 5.5–10.9) 27 112 47 (IQR: 33–65) 39 (28%) 48 (35%) 37 (27%) 15 (11%) 17 (12%) 27 (19%) 65 (47%) 30 (22%)
Eure, 2019 [30] 0 5.9 (IQR: 5.0–6.4) 2 7 37 (IQR: 33–44) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Ghai, 2022 [31] 94 6.37 (IQR: 5.1–8.4) 57 37 49 (IQR: 34–64) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Hofbauer, 2022 [32] 147 6.5 (IQR: 4.8–9.3) 31 172 48 (IQR: 37–63) 16 (7%) 56 (28%) 96 (47%) 35 (17%) 15 (7.5%) 37 (18%) 109 (54%) 41 (20%)
Khajir, 2025 [33]
ExactVu 261 6.70 (IQR: 4.8–9.5) 94 287 49 (IQR: 35–71) ‐ ‐ ‐ ‐ 24 (6%) 80 (19%) 198 (46%) 127 (30%)
Artemis 280 7.66 (IQR: 5.4–10.8) 120 346 55 (IQR: 40–77) ‐ ‐ ‐ ‐ 30 (6%) 95 (20%) 200 (43%) 145 (31%)
Kinnaird, 2025 [11]
Micro‐US 121 7.2 (IQR: 5.5–11) 25 64 ‐ 24 (20%) 21 (18%) 43 (36%) 24 (20%) ‐ ‐ ‐ ‐
MRI/US 331 6.7 (IQR: 5.1–9.5) 81 196 ‐ ‐ ‐ ‐ ‐ 111 (48%) 42 (14%) 84 (27%) 70 (23%)
Klotz, 2020 [34] 407 7 (IQR: 5.1–10) 208 832 38 (IQR: 28–53) 166 (16%) 177 (17%) 686 (66%) 372 (36%) 124 (12%) 351 (34%) 193 (18%)
Lorusso, 2022 [35] 0 6.2 (R: 2.4–15.9) 7 9 51 (R: 35–98) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Lughezzani, 2020 [36] 200 7.3 (IQR: 5.2–9.9) 72 248 45 (IQR: 30–70) 65 (20.3%) 38 (11.9%) 159(49.7%) 58 (18.1%) ‐ 56 (17.5%) 209 (65.3%) 55 (17.2%)
Pereira‐Arias, 2019 [37] 51 7.5 (R: 1.26‐34.9) ‐ ‐ 48 (R: 15–113) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Piccolini, 2024 [38]
Micro‐US ‐ 6.6 (IQR: 5–9) 143 439 50 (IQR: 38–70) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
mp‐MRI ‐ 6.7 (IQR: 5–9) 140 372 50 (IQR: 35–68) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Pickersgill, 2025 [39] 115 7.6 (SD: ±0.6) ‐ ‐ 56.2 (SD: 30.3) 50 (31%) 111 (68.9%) 69 (43%) 16 (9.9%) 38 (23.6%) 38 (23.6%)
Rojo, 2024 [40] ‐ 7.66 (SD: ±6.29) ‐ ‐ 61.34 (SD:± 31.7) ‐ 17 (14.4%) 80 (67.8%) 21 (17.8%) ‐ 33 (31.7%) 56 (53.8%) 15 (14.4%)
Socarrás, 2020 [41] 129 6.5 (IQR:4.7–9.2) 31 163 58.1 (IQR: 36.6–81.5) ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
Wiemer, 2021 [42] 79 7.59 (IQR: 5.8–11.5) 42 117 53 (IQR: 35.5–76.5) 16 (15%) 22 (14%) 74 (47%) 47 (30%) 7 (5%) 15 (9%) 74 (47%) 63 (40%)

DRE, digital rectal examination; IQR, interquartile range; PSA, prostate‐specific antigen; R, range; SD, standard deviation.

Imaging Acquisition Parameters for Micro‐US and MRI

Across all studies, suspicious lesions were defined as PI‐RADS ≥3 and PRI‐MUS ≥3, as both scores are used as common thresholds to define a positive, suspicious lesion that warrants a biopsy. The operators performing micro‐US‐TBx received appropriate training and most of the mpMRIs were evaluated by a radiologist experienced in mpMRI. Moreover, all mpMRIs were performed with a strength of 1.5 or 3 Tesla with or without endorectal coil placement and one study included biparametric MRI (bpMRI) [27]. The operator was blinded to the MRI results at the time of micro‐US‐TBx in 15 studies and unblinded in seven (Table S1).

Among the studies reporting PRI‐MUS, a total of 1811 patients were assessed. Of these, 449 (24.8%) had a PRI‐MUS score of 1–2, 639 (35.3%) a score of 3, 493 (27.2%) a score of 4, and 230 (12.7%) a score of 5. For PI‐RADS, data were available for 3113 patients. The distribution was 618 (19.9%) with a PI‐RADS score of 1–2, 588 (18.9%) with a score of 3, 1140 (36.6%) with a score of 4, and 767 (24.6%) with a score of 5. Notably, high‐grade lesions (scores 4–5) were more frequent with PI‐RADS (61.2%) than with PRI‐MUS (39.9%), whereas intermediate findings (score 3) were proportionally higher with PRI‐MUS (35.3%) compared to PI‐RADS (18.9%).

Methodological Quality of Studies

On QUADAS‐2, the patient selection domain was rated low risk of bias in 14/22 studies (63.6%; Fig. 2). The reference standard domain was low risk in 21/22 (95.4%), as histopathology served as the reference standard (targeted biopsy and/or radical prostatectomy were considered appropriate). The index test domain was judged low risk in 19/22 studies (86.3%). Likewise, the flow and timing domain was low risk in 19/22 (86.3%). No study raised concerns regarding applicability in any domain (Fig. S2).

Fig. 2.

Fig. 2

Pooled sensitivity and specificity: MRI‐TBx vs Micro‐US‐TBx for csPCa (GG ≥2).

Despite the comparable diagnostic yields reported, our GRADE assessment classified the certainty of evidence as predominantly low. This is largely a reflection of the significant heterogeneity across the included studies—ranging from varying biopsy protocols to the lack of a consistent reference standard. Such variability limits the weight of these findings in the context of clinical guidelines; they should be viewed as a signal of potential rather than a mandate for practice change. To bridge this gap, future research must shift away from small, heterogeneous cohorts. We need multicentre trials with standardised training for operators, as the learning curve for micro‐US remains a critical confounder. Only by reducing this ‘user‐dependency’ and focusing on well‐defined patient groups can we determine if micro‐US‐TBx is a true successor to MRI‐TBx or a specialised niche tool.

Detection Rates

We included 19 studies comprising 5581 participants who underwent micro‐US‐TBx and 5937 who underwent MRI‐TBx. Micro‐US‐TBx detected 2037 cases of csPCa (GG ≥2), while MRI‐TBx detected 2043 cases. The pooled detection ratio (DR) for csPCa comparing micro‐US with MRI was 1.04 (95% CI 0.95–1.15; I 2 = 61.1%; Fig. 1). Funnel plot inspection and Egger's test revealed no evidence of significant publication bias among the included studies (P = 0.848; Fig. S3).

Fig. 1.

Fig. 1

Forest plot of detection rates: micro‐US‐TBx vs MRI‐TBx for csPCa (GG ≥2).

Micro‐US‐TBx Diagnostic Accuracy

The sensitivity and specificity of micro‐US‐TBx across the included studies (n = 10) ranged from 0.72 to 1.00 and 0.00 to 1.00, respectively. The pooled sensitivity was 0.88 (95% CI 0.80–0.93), while the pooled specificity was 0.25 (95% CI 0.19–0.33). Heterogeneity was substantial, with I 2 values from the bivariate model ranging between 83.7% and 84.4% (Fig. 2).

The MRI Diagnostic Accuracy

The sensitivity and specificity of MRI‐TBx across the included studies (n = 13) ranged from 0.55 to 1.00 and 0.01 to 1.00, respectively. The pooled sensitivity was 0.81 (95% CI 0.74–0.86), and the pooled specificity was 0.17 (95% CI 0.10–0.27). Heterogeneity, assessed using the bivariate model, was high, with I 2 values ranging from 88.3% to 95.8% (Fig. 2).

Diagnostic Accuracy Comparison

The 95% prediction regions of the SROC curves overlapped substantially, indicating similar performance between modalities. In a bivariate random‐effects meta‐regression with imaging modality as a covariate, model‐based areas under the curve were closely aligned (MRI, 0.547; micro‐US, 0.658). Modality effects were not significant for sensitivity (estimate = 0.09; 95% CI −0.04 to 0.22; P = 0.192) or specificity (estimate = 0.49; 95% CI −0.36 to 1.34; P = 0.257). These results indicate no statistically significant advantage of either technique (Fig. 3; Fig. S5).

Fig. 3.

Fig. 3

Comparative SROC: micro‐US‐TBx vs MRI‐TBx.

Discussion

Summary of Results

This study represents the largest systematic review and meta‐analysis to date and the first to incorporate the OPTIMUM randomised clinical trial [11]. In this analysis of 22 studies, we compared the diagnostic performance and csPCa detection rates of micro‐US‐TBx and MRI‐TBx. The pooled results demonstrated comparable csPCa detection between the two modalities, supporting micro‐US‐TBx as a feasible and clinically meaningful alternative to MRI‐TBx.

Outcomes

This review synthesises head‐to‐head evidence comparing micro‐US‐TBx with MRI‐TBx for diagnosing csPCa. Across the included studies, DR, sensitivity, and specificity for csPCa did not differ significantly between the two modalities. Specifically within the randomised OPTIMUM trial [11], micro‐US‐TBx met pre‐specified non‐inferiority thresholds relative to MRI‐TBx. Given its comparable diagnostic accuracy and potential to streamline evaluations, micro‐US may reduce unnecessary interventions without compromising csPCa detection. Taken together, the comparable outcomes observed in prior prospective studies [43, 44], reinforced by the non‐inferiority established in the OPTIMUM trial [11], support the utility of micro‐US‐guided biopsy as a valid alternative to MRI–US fusion‐guided biopsy.

The Lancet Commission on Prostate Cancer [44, 45] has underscored the urgent need to reassess diagnostic pathways to enhance accuracy, reduce missed diagnoses of csPCa, and minimise the overdiagnosis and overtreatment of indolent disease. Given that ~4 million prostate MRIs are performed annually, this issue has significant global health implications. Incorporating novel strategies such as micro‐US‐TBx could alleviate scanner and workforce demands, broaden access to imaging, and even yield substantial cost savings [46].

While our analysis did not assess the cost‐effectiveness of micro‐US‐TBx for the detection of csPCa, the substantial findings—particularly from the OPTIMUM trial—suggest that micro‐US‐TBx warrants evaluation from a health economics perspective. Future studies should assess its viability as a complement to, or potentially a substitute for, MRI within the csPCa screening pathway.

Active surveillance is endorsed by major urological guidelines as the preferred strategy for managing patients with ciPCa [5, 7]. The role of micro‐US in this setting has been evaluated against mpMRI for detecting progression from GG 1 to GG ≥2, and a PRI‐MUS threshold ≥3 achieved 97% sensitivity for identifying csPCa [47]. In this study, no significant difference was observed between the two modalities in identifying GG ≥2 lesions; however, micro‐US using a PRI‐MUS threshold ≥3 demonstrated greater sensitivity than mpMRI with a PI‐RADS threshold ≥3 (86% vs 84%, respectively). These findings suggest that micro‐US may offer superior sensitivity in the active surveillance population, with additional advantages in terms of cost‐effectiveness and accessibility to be further investigated in future studies.

Recent studies have focused on optimising the detection of csPCa without increasing the diagnosis of ciPCa. The PRIME study (ClinicalTrials.gov identifier: NCT04571840) [48] demonstrated that bpMRI, a shorter and less resource‐intensive protocol, achieves comparable detection rates of csPCa to full mpMRI, while avoiding an increase in ciPCa diagnoses. Similarly, the OPTIMUM trial [11] showed that micro‐US‐guided biopsy was non‐inferior to MRI/conventional US fusion‐guided biopsy for detecting csPCa in biopsy naïve men.

This review synthesises contemporary evidence to inform recommendations on micro‐US‐TBx. Because micro‐US‐TBx is operator‐dependent and requires structured training, diagnostic performance varied across studies and correlated with operator experience. In 14 studies, urologists had completed formal training through the Exact Imaging programme, and in three studies operators reported >3 years of experience. Reader experience is a key determinant of mpMRI performance. Dedicated uroradiologists demonstrate higher inter‐reader agreement than non‐specialists, with the highest agreement seen for clearly malignant lesions (PI‐RADS 4–5) and in patients with elevated PSA density or high clinical suspicion [49]. In our review, nine studies reported radiologist experience ranging from 2 to 30 years, which may have contributed to inter‐reader variability across the included studies.

These learning‐curve effects should be considered when interpreting comparative accuracy estimates and when planning implementation. Although micro‐US enables real‐time targeting of suspicious lesions, it still demands dedicated equipment and skilled personnel, which may limit scalability for rapid assessments and routine surveillance in some settings. Where available, its high‐resolution, point‐of‐care imaging has the potential to streamline PCa diagnostic pathways and support earlier, more confident treatment decisions.

Strengths

Our study exhibits several strengths. First, in our head‐to‐head meta‐analysis, modality‐level meta‐regression (micro‐US‐TBx vs MRI‐TBx) showed no evidence of superiority for either technique in DR, sensitivity or specificity; the corresponding SROC curves largely overlapped. Second, our study updated the diagnostic accuracy performance between micro‐US‐TBx and MRI‐TBx with a large multicentre RCT [11] and 12 prospective studies [22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42] and the inclusion of a large sample of multiple centres ensure comprehensive heterogeneity. Additionally, the determination of the presence or absence of csPCa was based on most available histopathological evidence, and reduced the biased whole‐mount histopathology, which might be prone to sampling errors.

Limitations

Limitations include heterogeneity in biopsy triggers across studies. Most trials triaged men to TBx only when PI‐RADS ≥3, whereas some protocols mandated biopsies for all enrolled participants—an approach that diverges from contemporary practice. Such differences in verification strategies and disease spectrum can shift observed detection rates and test characteristics, limiting generalisability to routine care, where men with PI‐RADS 1–2 and favourable PSA density commonly forgo biopsy. Second, several studies mandated a concomitant systematic biopsy (SBx) in addition to image‐guided TBx. This design complicates estimation of the standalone (‘pure’) accuracy of micro‐US‐TBx and MRI‐TBx by introducing partial‐verification/incorporation bias, as disease ascertainment is augmented by SBx rather than the targeted approach alone. Practice patterns also vary geographically: some contemporary protocols omit SBx when performing TBx in selected patients, which limits direct comparability across studies and constrains generalisability to settings that do not routinely use SBx. Third, study personnel were not blinded to the assigned biopsy technique, introducing a risk of performance and assessment bias. Fourth, the cohorts combined biopsy naïve patients, men undergoing repeat biopsy, and individuals on active surveillance, creating heterogeneity in baseline oncological risk and disease prevalence that may affect accuracy estimates and limit generalisability. Although prior meta‐analyses [50] estimated mpMRI sensitivity at 0.90 (95% CI 0.87–0.93) and specificity at 0.64 (95% CI 0.50–0.76), our pooled estimates were lower—sensitivity 0.84 (95% CI 0.76–0.90) and specificity 0.40 (95% CI 0.27–0.55)—likely reflecting differences in reader expertise, patient spectrum, verification strategies, and threshold definitions. Other limitations include heterogeneity in reader expertise and the potential impact of learning‐curve effects related to PRI‐MUS scoring. As a relatively new and operator‐dependent imaging modality, micro‐US relies heavily on the examiner's experience for lesion classification and target selection, which may introduce inter‐operator variability and influence pooled accuracy estimates. In addition, heterogeneity in the analysed populations represents an important limitation. Most included studies did not report individual‐level data or subgroup‐specific outcomes for biopsy naïve patients, repeat‐biopsy patients, or men undergoing active surveillance, precluding the performance of subgroup analyses to further explore sources of heterogeneity.

Another limitation of this review is that biopsy histopathology was used as the reference standard in the included studies. As this reference is not independent of the index tests and does not represent the true disease status, diagnostic accuracy estimates should be interpreted with caution.

An important methodological consideration relates to inherent differences in image acquisition and interpretability between MRI‐TBx and micro‐US‐TBx. MRI datasets are digitally stored and can be reviewed retrospectively at different time points, allowing independent reassessment by multiple observers, secondary reads, and formal quality control procedures. This capacity enhances reproducibility analyses and mitigates single‐operator bias. Another limitation of this study is the potential for incorporation bias and partial verification bias, as several included studies [26, 28, 29, 30, 31, 32, 33, 34, 36, 37, 41, 42] combined SBx with TBx in their diagnostic protocols, as summarised in Table 1. Whenever possible, only data derived from TBx cores were extracted and included in the analysis. Results from SBx or random biopsies were excluded to ensure that the pooled estimates reflected the diagnostic performance of image‐guided TBx alone.

Conclusions

This systematic review and meta‐analysis provides an up‐to‐date evaluation of the diagnostic performance of micro‐US‐TBx compared with MRI‐TBx for the detection of csPCa. Our findings indicate that micro‐US‐TBx achieves detection rates and diagnostic accuracy comparable to those of MRI‐TBx, consistent with previous reports. Direct comparative analyses showed no statistically significant differences in diagnostic performance between the two modalities, suggesting similar effectiveness under comparable clinical conditions.

This review suggests that micro‐US‐TBx may represent a valuable complementary tool within contemporary PCa diagnostic pathways, given its high sensitivity, comparable DRs, and the ability to integrate systematic sampling with real‐time targeting of suspicious lesions during biopsy. Nevertheless, further cost‐effectiveness analyses are warranted to better define its role and optimal implementation in clinical practice.

Disclosure of Interests

The authors declare that they have no conflicts of interest relevant to this work. No financial, personal, or institutional relationships exist that could inappropriately influence or bias the content of this manuscript.

Supporting information

Appendix S1. Search strategy.

Table S1. Comparative imaging acquisition characteristics.

Fig. S1. The PRISMA 2020 flow diagram of the literature search and selection.

Fig. S2. The QUADAS‐2.

Fig. S3. Funnel plot of pooled DR.

Fig. S4. Certainty of evidence (GRADE) by outcome.

Fig. S5. Pooled accuracy (Violin Plot) comparing MicroUS‐TBx and MRI‐TBx.

BJU-138-196-s001.docx (641.1KB, docx)

References

  • 1. Siegel RL, Miller KD, Jemal A. Cancer statistics, 2018. CA Cancer J Clin 2018; 68: 7–30 [DOI] [PubMed] [Google Scholar]
  • 2. Bray F, Ferlay J, Soerjomataram I, Siegel RL, Torre LA, Jemal A. Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin 2018; 68: 394–424 [DOI] [PubMed] [Google Scholar]
  • 3. Wei JT, Barocas D, Carlsson S et al. Early detection of prostate cancer: AUA/SUO guideline part I: prostate cancer screening. J Urol 2023; 210: 45–53 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4. Tamada T, Takeuchi M, Watanabe H et al. Differentiating clinically significant prostate cancer from clinically insignificant prostate cancer using qualitative and semi‐quantitative indices of dynamic contrast‐enhanced MRI. Discov Oncol 2024; 15: 770 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5. Elwenspoek MMC, Sheppard AL, McInnes MDF et al. Comparison of multiparametric magnetic resonance imaging and targeted biopsy with systematic biopsy alone for the diagnosis of prostate cancer: a systematic review and meta‐analysis. JAMA Netw Open 2019; 2: e198427 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6. Stabile A, Giganti F, Rosenkrantz AB et al. Multiparametric MRI for prostate cancer diagnosis: current status and future directions. Nat Rev Urol 2020; 17: 41–61 [DOI] [PubMed] [Google Scholar]
  • 7. European Association of Urology . EAU Guidelines. Presented at the EAU Annual Congress Madrid 2025. Arnhem: EAU Guidelines Office, 2025. [Google Scholar]
  • 8. Wegelin O, Exterkate L, van der Leest M et al. The FUTURE trial: a multicenter randomised controlled trial on target biopsy techniques based on magnetic resonance imaging in the diagnosis of prostate cancer in patients with prior negative biopsies. Eur Urol 2019; 75: 582–590 [DOI] [PubMed] [Google Scholar]
  • 9. DuBois J, Smani S, Golos A, Rivera Lopez C, Lokeshwar SD. Micro‐ultrasound in the detection of clinically significant prostate cancer: a comprehensive review and comparison with multiparametric MRI. Tomography 2025; 11: 80 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Pensa J, Brisbane W, Kinnaird A et al. Evaluation of prostate cancer detection using micro‐ultrasound versus MRI through co‐registration to whole‐mount pathology. Sci Rep 2024; 14: 18910 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. Kinnaird A, Luger F, Cash H et al. Microultrasonography‐guided vs MRI‐guided biopsy for prostate cancer diagnosis: the OPTIMUM randomized clinical trial. JAMA 2025; 333: 1679–1687 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12. Page MJ, Moher D, Bossuyt PM et al. PRISMA 2020 explanation and elaboration: updated guidance and exemplars for reporting systematic reviews. BMJ 2021; 372: n160 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13. Micheleto JP, Suartz CV. Micro‐ultrasound compared with multiparametric MRI‐targeted biopsy in detecting clinically significant prostate cancer: updated systematic review and meta‐analysis. PROSPERO 2025; CRD420251155775 [Google Scholar]
  • 14. Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan—a web and mobile app for systematic reviews. Syst Rev 2016; 5: 210 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15. R Core Team . R: a Language and Environment for Statistical Computing. Vienna: R Foundation for Statistical Computing, 2023. [Google Scholar]
  • 16. Cochran WG. The comparison of percentages in matched samples. Biometrika 1950; 37: 256–266 [PubMed] [Google Scholar]
  • 17. Higgins JPT, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta‐analyses. BMJ 2003; 327: 557–560 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18. Whiting PF, Rutjes AWS, Westwood ME et al. QUADAS‐2: a revised tool for the quality assessment of diagnostic accuracy studies. Ann Intern Med 2011; 155: 529–536 [DOI] [PubMed] [Google Scholar]
  • 19. Sterne JAC, Sutton AJ, Ioannidis JPA et al. Recommendations for examining and interpreting funnel plot asymmetry in meta‐analyses of randomised controlled trials. BMJ 2011; 343: d4002 [DOI] [PubMed] [Google Scholar]
  • 20. Balduzzi S, Rücker G, Schwarzer G. How to perform a meta‐analysis with R: a practical tutorial. Evid Based Ment Health 2019; 22: 153–160 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21. Doebler P. mada: meta‐analysis of diagnostic accuracy. R package version 0.5–7. 2015.
  • 22. Abouassaly R, Klein EA, El‐Shefai A et al. Impact of using 29 MHz high‐resolution micro‐ultrasound in real‐time targeting of transrectal prostate biopsies: initial experience. World J Urol 2020; 38: 1201–1206 [DOI] [PubMed] [Google Scholar]
  • 23. Albers P, Bennett J, Evans M et al. Micro‐ultrasound for the detection of clinically significant prostate cancer in biopsy‐naïve men with negative MRI. Can Urol Assoc J 2024; 18: 208 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24. Avolio PP, Piccolini A, Saitta C et al. Enhanced diagnostic accuracy of micro‐ultrasound in prostate cancer detection: an updated series from a single‐center prospective study. Urol Oncol 2025; 43: 470.e19–470.e26 [DOI] [PubMed] [Google Scholar]
  • 25. Beatrici E, Frego N, Chiarelli G et al. A comparative evaluation of multiparametric magnetic resonance imaging and micro‐ultrasound for the detection of clinically significant prostate cancer in patients with prior negative biopsies. Diagnostics (Basel) 2024; 14: 525 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26. Claros OR, Tourinho‐Barbosa RR, Fregeville A et al. Comparison of initial experience with transrectal magnetic resonance imaging cognitive guided micro‐ultrasound biopsies versus established transperineal robotic ultrasound magnetic resonance imaging fusion biopsies for prostate cancer. J Urol 2020; 203: 918–925 [DOI] [PubMed] [Google Scholar]
  • 27. Cornud F, Lefevre A, Flam T et al. MRI‐directed high‐frequency (29 MHz) TRUS‐guided biopsies: initial results of a single‐center study. Eur Radiol 2020; 30: 4838–4846 [DOI] [PubMed] [Google Scholar]
  • 28. Dagnino F, Avolio PP, Fasulo V et al. Clinically significant prostate cancer detection rate in biopsy‐naïve patients with mpMRI and microultrasound topographically discordant lesions: a single‐center retrospective analysis. Urol Oncol 2024; 42: 447.e11–447.e16 [DOI] [PubMed] [Google Scholar]
  • 29. Dias N, Colandrea G, Botelho F et al. Diagnostic accuracy and clinical utility of micro‐ultrasound guided biopsies in patients with suspected prostate cancer. Cent European J Urol 2023; 76: 25–32 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30. Eure G, Fanney D, Lin J, Wodlinger B, Ghai S. Comparison of conventional transrectal ultrasound, magnetic resonance imaging, and micro‐ultrasound for visualizing prostate cancer in an active surveillance population: a feasibility study. Can Urol Assoc J 2019; 13: E70–E77 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31. Ghai S, Perlis N, Atallah C et al. Comparison of micro‐US and multiparametric MRI for prostate cancer detection in biopsy‐naïve men. Radiology 2022; 305: 390–398 [DOI] [PubMed] [Google Scholar]
  • 32. Hofbauer SL, Luger F, Harland N et al. A non‐inferiority comparative analysis of micro‐ultrasonography and MRI‐targeted biopsy in men at risk of prostate cancer. BJU Int 2022; 129: 648–654 [DOI] [PubMed] [Google Scholar]
  • 33. Khajir G, Webb LT, Lokeshwar SD et al. Diagnostic performance of high‐resolution micro‐ultrasound and conventional ultrasound in fusion biopsy for clinically significant prostate cancer detection. Urol Oncol 2025; 43: 399.e1–399.e8 [DOI] [PubMed] [Google Scholar]
  • 34. Klotz L, Lughezzani G, Maffei D et al. Comparison of micro‐ultrasound and multiparametric magnetic resonance imaging for prostate cancer: a multicenter prospective analysis. Can Urol Assoc J 2021; 15: E11–E16 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35. Lorusso V, Kabre B, Pignot G et al. Comparison between micro‐ultrasound and multiparametric MRI regarding the correct identification of prostate cancer lesions. Clin Genitourin Cancer 2022; 20: e339–e345 [DOI] [PubMed] [Google Scholar]
  • 36. Lughezzani G, Maffei D, Saita A et al. Diagnostic accuracy of microultrasound in patients with a suspicion of prostate cancer at magnetic resonance imaging: a single‐institution prospective study. Eur Urol Focus 2021; 7: 1019–1026 [DOI] [PubMed] [Google Scholar]
  • 37. Pereira‐Arias JG, Sánchez‐Vázquez A, Gamarra‐Quintanilla M et al. Prostatic high‐resolution micro‐ultrasound imaging. Arch Esp Urol 2019; 72: 804–815 [PubMed] [Google Scholar]
  • 38. Piccolini A, Avolio PP, Saitta C et al. A propensity score‐matched comparison of micro‐ultrasound‐guided transrectal and MRI/TRUS fusion‐guided transperineal prostate biopsies for detection of clinically significant prostate cancer. Eur Urol Open Sci 2024; 69: 7–12 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39. Pickersgill NA, Alkazemi MH, Ostergar A et al. Correlation of prostate high‐resolution microultrasound with multiparametric magnetic resonance imaging. Urology 2025; 197: 33–39 [DOI] [PubMed] [Google Scholar]
  • 40. García Rojo E, García Gómez B, Sopeña Sutil R et al. Comparison in detection rate of clinically significant prostate cancer between microultrasound‐guided prostate biopsy and multiparametric MRI‐guided prostate biopsy. Urology 2024; 183: 163–169 [DOI] [PubMed] [Google Scholar]
  • 41. Rodríguez Socarrás ME, Gomez Rivas J, Cuadros Rivera V et al. Prostate mapping for cancer diagnosis: the Madrid protocol. J Urol 2020; 204: 726–733 [DOI] [PubMed] [Google Scholar]
  • 42. Wiemer L, Hollenbach M, Heckmann R et al. Evolution of targeted prostate biopsy by adding micro‐ultrasound to the magnetic resonance imaging pathway. Eur Urol Focus 2021; 7: 1292–1299 [DOI] [PubMed] [Google Scholar]
  • 43. Sountoulides P, Pyrgidis N, Polyzos SA et al. Micro‐ultrasound‐guided vs multiparametric MRI‐targeted biopsy in the detection of prostate cancer: a systematic review and meta‐analysis. J Urol 2021; 205: 1254–1262 [DOI] [PubMed] [Google Scholar]
  • 44. You C, Li X, Du Y et al. Microultrasound‐guided prostate biopsy in detection of prostate cancer: a systematic review and meta‐analysis. J Endourol 2022; 36: 394–402 [DOI] [PubMed] [Google Scholar]
  • 45. James ND, Tannock I, N'Dow J et al. The lancet commission on prostate cancer: planning for the surge in cases. Lancet 2024; 403: 1683–1722 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46. Beatrici E, De Carne F, Frego N et al. Optimizing prostate cancer diagnostic work‐up through micro‐ultrasound: minimizing unnecessary procedures and reducing overdiagnoses. Prostate 2025; 85: 603–611 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47. Albers P, Wang B, Broomfield S, Medina Martín A, Fung C, Kinnaird A. Micro‐ultrasound versus magnetic resonance imaging in prostate cancer active surveillance. Eur Urol Open Sci 2022; 46: 33–35 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 48. Ng AB, Asif A, Agarwal R et al. Biparametric vs multiparametric MRI for prostate cancer diagnosis: the PRIME diagnostic clinical trial. JAMA 2025; 334: 1170–1179 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 49. Brembilla G, Dell'Oglio P, Stabile A et al. Interreader variability in prostate MRI reporting using prostate imaging reporting and data system version 2.1. Eur Radiol 2020; 30: 3383–3392 [DOI] [PubMed] [Google Scholar]
  • 50. Garcia‐Becerra CA, Arias‐Gallardo MI, Juarez‐Garcia JE et al. Head‐to‐head comparison of diagnostic test accuracy between biparametric and multiparametric MRI: an updated systematic review and bivariate meta‐analysis. Prostate Cancer Prostatic Dis 2025; 28: 993–1004 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Appendix S1. Search strategy.

Table S1. Comparative imaging acquisition characteristics.

Fig. S1. The PRISMA 2020 flow diagram of the literature search and selection.

Fig. S2. The QUADAS‐2.

Fig. S3. Funnel plot of pooled DR.

Fig. S4. Certainty of evidence (GRADE) by outcome.

Fig. S5. Pooled accuracy (Violin Plot) comparing MicroUS‐TBx and MRI‐TBx.

BJU-138-196-s001.docx (641.1KB, docx)

Articles from Bju International are provided here courtesy of Wiley

RESOURCES