Abstract
Purpose
Advanced age-related macular degeneration (AMD) is a leading cause of irreversible vision loss worldwide, with photoreceptor degeneration representing the final common pathway of functional impairment. Optical coherence tomography (OCT) enables noninvasive, layer-resolved quantification of photoreceptor integrity using biomarkers of the ellipsoid zone (EZ), the outer nuclear layer (ONL), and the external limiting membrane (ELM). However, substantial heterogeneity in definitions, measurement protocols, and reporting practices limits cross-study comparability and the adoption of clinical trials. This scoping review with nested meta-analyses maps how axial photoreceptor biomarkers are operationalized, segmented, validated, and related to functional and multimodal endpoints in AMD.
Methods
MEDLINE, Embase, and Scopus were searched from January 2015 to December 2025 following PRISMA-ScR guidelines. Eligible studies reported OCT-based photoreceptor biomarkers in AMD populations. Data extraction captured boundary definitions, imaging platforms, segmentation approaches, analytic domains, ROI strategies, phenotypic context, reliability statistics, structure–function correlations, and OCT–FAF agreement.
Results
Ninety-four studies met inclusion criteria, spanning spectral-domain and swept-source OCT platforms and diverse AMD phenotypes. Marked variability was observed in boundary definitions (e.g., EZ–RPE vs. EZ–Bruch’s membrane), measurement strategies (thickness, area, volume, reflectivity), and spatial sampling (central 1 mm, ETDRS subfields, lesion-centric masks). When segmentation boundaries and analytic conventions were explicitly defined and consistently applied, reliability for EZ and ONL metrics was high (ICC > 0.90), with automated and deep-learning methods performing comparably to expert manual grading. Structure–function analyses demonstrated moderate-to-strong correlations between photoreceptor loss and microperimetry sensitivity (r = 0.50–0.80) and best-corrected visual acuity (r = 0.40–0.70), particularly in advanced disease stages. OCT–FAF agreement for geographic atrophy detection was similarly high (κ > 0.80), although early atrophic features showed greater definitional variability. Phenotypic stratification and topographic reporting were inconsistently documented.
Conclusion
OCT-derived photoreceptor biomarkers show high analytical reliability and clinically meaningful structure–function associations when segmentation boundaries, analytic domains, and reporting conventions are clearly specified. However, the review identifies substantial construct heterogeneity that complicates cross-study comparability and endpoint interpretation. Adoption of consensus boundary definitions, minimum reporting standards, and harmonized validation frameworks is necessary to ensure reproducibility, facilitate regulatory evaluation, and enable integration of photoreceptor metrics into AMD prevention and early-intervention trials. These findings provide the conceptual foundation for the CLEAR initiative (Consensus Layer Evaluation for AI Algorithm Reporting).
Keywords: age related macular degeneration, biomarkers, ellipsoid zone (EZ), external limiting membrane, outer nuclear layer, photoreceptor, reliability, scoping review
1. Introduction
Advanced age-related macular degeneration (AMD) [namely geographic atrophy (GA) and neovascular AMD (nAMD)] is associated with major functional disability, reduced quality of life, loss of independence, increased risk of depression and falls (1), and critically is a leading cause of irreversible vision loss in older adults worldwide, and its prevalence is expected to increase substantially (2, 3). Divergent regulatory decisions on complement inhibitors for GA across regulatory bodies have introduced confusion to the therapeutic landscape (4, 5), intensifying the need for sensitive, reproducible structural endpoints that capture disease activity earlier than conventional visual acuity or GA area alone.
Visual loss in AMD is most directly attributable to photoreceptor degeneration and dysfunction, which, although often preceded by RPE and choriocapillaris compromise, represents the proximate structural correlate of irreversible functional impairment (6, 7). Histologic and in vivo OCT studies show that thinning and disruption of the photoreceptor biomarkers ellipsoid zone (EZ) and outer nuclear layer (ONL) can precede clinically evident atrophy and progress alongside established lesions, suggesting both early-marker and disease-tracking potential (8, 9). These structural changes are closely linked to functional impairment, particularly under low-luminance or scotopic conditions, which are not captured by standard high-contrast acuity (10, 11). Microperimetry and psychophysical studies consistently demonstrate that local EZ or ONL loss corresponds to reduced retinal sensitivity and scotomata (12, 13).
Optical coherence tomography (OCT) has enabled non-invasive, layer-resolved imaging of these outer retinal changes. Advances from time-domain to spectral-domain and swept-source OCT have improved axial resolution, depth penetration, and volumetric acquisition, supporting quantitative assessment of EZ, ONL, external limiting membrane (ELM), and related metrics of photoreceptor integrity (14–16). Quantitative measures now include thickness, area, volume loss, reflectivity-derived indices, and can be analyzed in B-scan, en face, or fully volumetric domains (17, 18). However, several of these measures, particularly reflectivity- and continuity-based EZ metrics, are sensitive to acquisition quality, segmentation conventions, and analytic choices, introducing potential ambiguity between biological change and measurement artifact. In parallel, automated and deep learning-based segmentation has made large-scale, reproducible quantification feasible in multicenter trials (19–21). Despite these advances, most OCT-derived photoreceptor biomarkers rely on axial thickness or reflectivity-based surrogates whose interpretation depends on how anatomical boundaries are defined and operationalized. The extent to which these measurements reflect stable biological constructs rather than boundary-dependent analytical conventions has not been systematically examined. Critically, AI performance and biomarker validity cannot be interpreted independently of the anatomical construct definition used as the reference standard.
The Classification of Atrophy Meeting (CAM) consensus established OCT-based definitions for incomplete and complete RPE and outer retinal atrophy (iRORA and cRORA), providing a standardized framework for GA assessment that complements fundus autofluorescence (FAF) (22–24). However, photoreceptor-specific biomarkers, which may precede complete atrophy and offer earlier intervention windows, remain heterogeneously defined and inconsistently reported across studies. This heterogeneity limits cross-study synthesis, regulatory acceptance, and clinical trial implementation. In response to these challenges, the Consensus Layer Evaluation for AI Algorithm Reporting (CLEAR) initiative was established to support harmonized evaluation of OCT-derived photoreceptor biomarkers and AI-enabled imaging endpoints in AMD. The present manuscript represents CLEAR Report 1 and focuses on the definitional, anatomical, and methodological foundations underpinning photoreceptor biomarker interpretation, reproducibility, and regulatory readiness.
Despite growing interest in photoreceptor biomarkers, the literature remains characterized by diverse operational definitions, measurement protocols, segmentation approaches, degrees of operability and robustness, and reporting conventions. Traditional systematic reviews with strict inclusion criteria may exclude valuable methodological insights, while purely narrative reviews lack quantitative synthesis of evidence on reliability and validity. A scoping review methodology, designed to map heterogeneous evidence and identify knowledge gaps, is ideally suited to this landscape (25, 26). By incorporating structured quantitative synthesis within the scoping framework, we summarize reliability metrics and structure–function associations while preserving the breadth necessary to capture definitional variability and methodological diversity.
This scoping review was designed to address five interrelated domains: (1) how axial photoreceptor OCT biomarkers are anatomically defined and operationalized; (2) segmentation methodology and reliability; (3) phenotypic context and reporting completeness; (4) structure–function relationships; and (5) concordance between OCT- and FAF-based atrophy assessment.
By integrating these domains, the review aims to delineate the current evidentiary foundation for photoreceptor biomarkers as candidate trial endpoints, identify areas of methodological convergence and persistent heterogeneity, and inform ongoing efforts toward consensus standardization, AI validation, and regulatory readiness within the CLEAR framework.
2. Methods
2.1. Methodological framework
This scoping review was designed and conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) (27). For domains in which pooling was performed, we evaluated the consistency of definitions and measurement conditions but did not apply formal quality scores, as these are not validated for the heterogeneous methodological landscape addressed by this review. We selected a scoping approach to comprehensively map the heterogeneous landscape of photoreceptor biomarker definitions, measurement protocols, and supporting evidence across the full spectrum of age-related macular degeneration. This broad mapping strategy was complemented by a structured quantitative synthesis of reliability and agreement metrics in domains with sufficient methodological comparability.
2.2. Eligibility criteria and outcomes
We included original clinical studies that reported quantitative axial measures of photoreceptor integrity or outer retinal structure, assessed using OCT or OCT-derived metrics, in eyes with AMD. Eligible study designs comprised randomized controlled trials, prospective and retrospective cohort studies, and case–control studies. Case series with fewer than 10 eyes, narrative reviews, editorials, conference abstracts without full text, and non-human studies were excluded.
Studies were required to report at least one predefined structural photoreceptor-related outcome corresponding anatomically to the photoreceptor unit, including metrics reflecting the photoreceptor axon (Henle fiber layer), cell body [outer nuclear layer (ONL)], inner segments [e.g., ellipsoid zone (EZ)], outer segments [e.g., interdigitation zone (IZ) or EZ–RPE thickness], or composite outer retinal biomarkers incorporating multiple photoreceptor substructures. For eligibility, imaging biomarkers were categorized based on the anatomical photoreceptor component they purported to measure (axon, cell body, inner segment, outer segment, or composite). Studies reporting integrity, thickness, reflectivity, or attenuation of these structures were included. Functional outcomes were extracted when available; however, they were not required for inclusion. Studies were not excluded based on OCT platform, scan density, or segmentation approach, reflecting the aim of mapping real-world methodological variability rather than enforcing artificial uniformity. Studies reporting only global retinal thickness measures without photoreceptor-specific assessment were excluded.
Where possible, we sought to extract phenotypic disease characteristics with established biological relevance, including drusen subtype, presence of SDD, and MNV subtype, as these features have been shown to reflect distinct pathophysiological pathways and progression patterns in retinal disease. However, no study was excluded for incomplete phenotypic reporting.
2.3. Literature search strategy
A comprehensive literature search was performed in MEDLINE (via PubMed), Embase, and Scopus. Searches were restricted to studies published between 1 January 2015 and 31 December 2025 and to English-language articles. The 2015 threshold was selected a priori to capture contemporary OCT imaging technologies, segmentation methodologies, and photoreceptor biomarker definitions relevant to current clinical and research practice. The search strategy combined controlled vocabulary and free-text terms relating to photoreceptor integrity, outer retinal structure, OCT imaging, and the disease of interest.
The full electronic search strategy for each database is provided in Supplementary methods. Reference lists of included studies and relevant reviews were manually screened to identify additional eligible articles. The search strategy was designed to prioritize sensitivity over specificity, with subsequent filtering at the screening stage.
2.4. Study selection
All records identified through the database searches were imported into a reference management software, and duplicates were removed. Two reviewers independently screened titles and abstracts for eligibility. Full-text articles were retrieved for all potentially relevant records and assessed independently by the same reviewers against the predefined inclusion and exclusion criteria. Discrepancies at any stage were resolved through discussion, with adjudication by a third reviewer when necessary.
The study selection process is summarized using a PRISMA flow diagram, detailing the number of records identified, screened, excluded, and included (Figure 1).
FIGURE 1.
Definitions, segmentation methodology, and inter-grader reliability of photoreceptor-related SD-OCT biomarkers across retinal diseases: a scoping review.
2.5. Data extraction and phenotype classification
Data extraction was performed independently by two reviewers using a standardized, pilot-tested extraction form. Extracted data included study design, sample size, demographic characteristics, disease indication and stage, imaging modality and acquisition parameters, photoreceptor-related structural outcomes, and statistical estimates relevant to reliability and agreement assessment. Detailed technical measurement parameters underpinning each photoreceptor biomarker, including segmentation boundaries, spatial scale, and region of interest, thresholding or normalization logic, analytic domain, and reported acquisition or grading constraints affecting operability, were systematically extracted and are summarized in Table 1.
TABLE 1.
Technical measurement parameters of OCT-derived photoreceptor biomarkers in AMD.
| Study | Photoreceptor term used in study | Inner boundary | Outer boundary | Boundary specification adequacy* | Measurement domain | Spatial Scale/ROI | Quantification Type | Thresholding/ Normalization |
|---|---|---|---|---|---|---|---|---|
| Abraham et al. (31) (Ophth Retina) | EZ–RPE thickness | EZ (border not specified; Cole RC)/EZ posterior surface (Duke RC implied) | RPE (surface not specified; Cole RC)/OS tip–inner RPE boundary (Duke RC) | Full | Volumetric + en face | ETDRS subfields | Thickness; area | EZ–RPE = 0 μm; ≤ 20 μm |
| Abraham et al. (31) (Ophth Retina) | ONL–RPE thickness | ONL posterior boundary (Cole RC)/OPL–ONL boundary (Duke RC) | RPE (unspecified)/OS tip–inner RPE boundary | Full | Volumetric + en face | ETDRS subfields | Thickness; area | EZ–RPE = 0 μm; ≤ 20 μm |
| Abraham et al. (31) (Ophth Retina) | Photoreceptor layer (ELM–OS/RPE) | ELM | OS tip/inner RPE boundary | Full | Volumetric + en face | ETDRS subfields | Thickness; area | EZ–RPE = 0 μm; ≤ 20 μm |
| Abraham et al. (31) (Ophth Retina) | Outer retina (OPL/ONL–OS/RPE) | OPL/ONL boundary | OS tip/inner RPE boundary | Full | Volumetric + en face | ETDRS subfields | Thickness; area | EZ–RPE = 0 μm; ≤ 20 μm |
| Bell et al. (32) | EZ integrity | EZ centreline (segmented through centre of band) | Not a thickness construct | Full | Volumetric | Central 2 mm | Binary/thickness | None |
| Bell et al. (32) | EZ–RPE thickness | EZ centreline | RPE segmentation line | Full | Volumetric | Central 2 mm | Binary/thickness | None |
| Bell et al. (32) | ILM–RPE thickness | ILM | RPE segmentation line | Full | Volumetric | Central 2 mm | Binary/thickness | None |
| Bell et al. (32) | Sub-RPE compartment (RPE–BM) | RPE segmentation line | BM | Full | Volumetric | Central 2 mm | Binary/thickness | None |
| Birner et al. (33) | EZ thickness | Inner boundary of EZ band | Outer boundary of IZ | Full | B-scan | ∼70 μm radius at MP loci | Thickness | None |
| Birner et al. (33) | ONL thickness | Outer border of OPL | ELM | Full | B-scan | ∼70 μm radius at MP loci | Thickness | None |
| Birner et al. (33) | Drusen volume | BM | Outer border of RPE | Full | B-scan | ∼70 μm radius at MP loci | Volume | None |
| Birner et al. (33) | HRF volume | Not defined by fixed interfaces (manual annotation) | Not defined by fixed interfaces | Full | B-scan | ∼70 μm radius at MP loci | Volume | None |
| Birner et al. (33) | SDD volume | RPE surface | BM band | Full | B-scan | ∼70 μm radius at MP loci | Volume | None |
| Birner et al. (34) | EZ thickness | Inner boundary of EZ | Outer boundary of IZ | Full | B-scan + volumetric | MP-aligned loci | Thickness; area | EZL vs. EZL + RPEL |
| Birner et al. (34) | EZ loss | Inner boundary of EZ | Outer boundary of IZ | Full | B-scan + volumetric | MP-aligned loci | Area | EZL vs. EZL + RPEL |
| Birner et al. (34) | RPE loss | RPE band ( ≥ 250 μm attenuation; CAM) | Not thickness-defined (DL loss map) | Full | B-scan + volumetric | MP-aligned loci | Area | EZL vs. EZL + RPEL |
| Birner et al. (34) | Drusen volume | BM | Outer border of RPE | Full | B-scan + volumetric | MP-aligned loci | Volume | EZL vs. EZL + RPEL |
| Bogunovic et al. (35) | ONL thickness | Algorithm-defined ONL inner boundary (Iowa) | Algorithm-defined ONL outer boundary | Partial | Volumetric | Macular grid | Thickness | None |
| Bogunović et al. (35) | ORB thickness | Lower ONL boundary | RPE surface | Partial | Volumetric | Macular grid | Thickness | None |
| Bogunović et al. (35) | Drusen thickness | RPE surface | BM surface | Partial | Volumetric | Macular grid | Thickness | None |
| Borrelli et al. (36) | EZ volume | ELM | IZ | Full | Volumetric | Macular ROIs | Volume | None |
| Borrelli et al. (36) | OS volume | EZ | IZ | Full | Volumetric | Macular ROIs | Volume | None |
| Borrelli et al. (37) | EZ normalized reflectivity | 45 μm above RPE reference (geometric slab) | 21 μm slab thickness (45–66 μm above RPE) | Partial | En face | Macular slab | Normalised intensity | EZ ÷ reference |
| Brandl et al. (17) | ONL thickness | OPL outer border | ELM | Full | Volumetric | ETDRS 1/3/6 mm | Thickness | None |
| Brandl et al. (17) | ORL thickness | ELM | BrM | Full | Volumetric | ETDRS 1/3/6 mm | Thickness | None |
| Brandl et al. (17) | RPE/BrM thickness | RPE | BrM | Full | Volumetric | ETDRS 1/3/6 mm | Thickness | None |
| Brandl et al. (17) | PR-IS/OS thickness | ELM | RPE | Full | Volumetric | ETDRS 1/3/6 mm | Thickness | None |
| Carvajal et al. (38) | iRORA | Not interface-defined (CAM criteria: RPE attenuation + hypertransmission + overlying PR degeneration incl. EZ/ELM/ONL) | Not interface-defined | Insufficient | B-scan | ETDRS grid | Binary; area | CAM GLD ≥ 250 μm |
| Carvajal et al. (38) | cRORA | Not interface-defined (CAM morphologic definition) | Not interface-defined | Insufficient | B-scan | ETDRS grid | Binary; area | CAM GLD ≥ 250 μm |
| Cedro et al. (39) | cRORA area | Not interface-defined (manual IR delineation + OCT confirmation; CAM-based) | Not interface-defined | Insufficient | B-scan | Lesion-centric | Area Ordinal Ordinal |
Square-root transform |
| Cedro et al. (39) | ELM disruption score | Qualitative grading | Qualitative grading | Insufficient | B-scan | Lesion-centric | Area Ordinal Ordinal |
Square-root transform |
| Cedro et al. (39) | IS/OS disruption score | Qualitative grading | Qualitative grading | Insufficient | B-scan | Lesion-centric | Area Ordinal Ordinal |
Square-root transform |
| Cheung et al. (40) | EZ sinuosity | EZ centreline (single line through hyperreflective band) | BM centreline (reference denominator) | Partial | B-scan | Central macula | Ratio R |
EZ > 1.01 |
| Cheung et al. (40) | RPE sinuosity | RPE centreline | BM centreline | Partial | B-scan | Central macula | Ratio R |
RPE > 1.03 |
| Coulibaly et al. (46) | EZ loss (EZL) | EZ segmentation line (AI-derived; inner/outer interface not explicitly specified) | Not thickness-defined (loss map) | Partial | Volumetric | Lesion-centric | Area (√mm) Area Ar |
Square-root growth rate |
| Coulibaly et al. (46) | RPE loss (RPEL) | RPE segmentation line | Not thickness-defined | Partial | Volumetric | Lesion-centric | Area (√mm) Area Ar |
Square-root growth rate |
| Coulibaly et al. (46) | ELM loss (ELML) | ELM segmentation line | Not thickness-defined | Partial | Volumetric | Lesion-centric | Area (√mm) Area Ar |
Square-root growth rate |
| Ehlers et al. (47) | OCT-GA (RPE loss) | RPE segmentation line | Bruch’s membrane (GA defined as RPE–BM = 0 μm) | Partial | Volumetric | Whole lesion | Area | FAF cross-confirmation |
| Etheridge et al. (49) | ONL thickness | OPL/ONL boundary (device-defined) | ELM | Partial | Volumetric | ETDRS rings | Thickness | Age-adjusted models |
| Etheridge et al. (49) | Outer retinal thickness | ELM | BM | Partial | Volumetric | ETDRS rings | Thickness | Age-adjusted models |
| Etheridge et al. (49) | PR layer | Device-defined PR compartment | Device-defined | Partial | Volumetric | ETDRS rings | Thickness | Age-adjusted models |
| Farinha et al. (50) | ONL thickness | OPL → ELM (device autosegmentation) | ELM | Partial | Volumetric | ETDRS 1/3/6 mm | Thickness | Bonferroni correction |
| Farinha et al. (50) | PRL (photoreceptor layer) | ELM | RPE/BrM complex | Partial | Volumetric | ETDRS 1/3/6 mm | Thickness | Bonferroni correction |
| Farinha et al. (50) | ORL | ELM | BrM | Partial | Volumetric | ETDRS 1/3/6 mm | Thickness | Bonferroni correction |
| Fasih-Ahmad et al. (51) | IZ thickness | Inner IZ boundary (hyperreflective pixel subjacent to EZ) | Outer IZ boundary (hyperreflective pixel above RPE) | Full | En face + volumetric | ETDRS outer ring | Thickness | None |
| Fasih-Ahmad et al. (51) | EZ area | EZ inner boundary | IZ outer boundary | Full | En face + volumetric | ETDRS outer ring | Area | None |
| Flynn et al. (53) | EZ integrity category | Qualitative EZ band continuity | Qualitative absence/presence | Insufficient | B-scan | Functional loci | Ordinal | Intact/attenuated/absent |
| Futterknecht et al. (56) | EZ/IZ loss | EZ/IZ disruption zone (no explicit anterior/posterior interface specification) | Hypertransmission region | Insufficient | Volumetric + targeted MP | Lesion-targeted grids | Sensitivity; lesion area | Distance- and size-adjusted error models |
| Gallagher et al. (57) | ONL thickness | OPL | ELM | Full | Volumetric | Central macula | Thickness | None |
| Gallagher et al. (57) | OSL (ELM–EZ–IZ band) | ELM | Outer border of EZ–IZ complex | Full | Volumetric | Central macula | Thickness | None |
| Gallagher et al. (57) | RPE–BrM thickness | RPE | BrM | Full | Volumetric | Central macula | Thickness | None |
| Ghoshal et al. (58) | ONL thickness | OPL | ELM | Partial | Volumetric | ETDRS central + inner ring | Thickness | None |
| Ghoshal et al. (58) | ORT (outer retina thickness) | ELM | BM | Partial | Volumetric | ETDRS central + inner ring | Thickness | None |
| Ghoshal et al. (58) | RPE–BM thickness | RPE | BM | Partial | Volumetric | ETDRS central + inner ring | Thickness | None |
| Goerdt et al. (59) | EZ band visibility | Qualitative band identification | Qualitative | Insufficient | B-scan | Eccentricity-specific loci | Visibility (%) | None |
| Goerdt et al. (59) | OSIZ-1/2 visibility | Qualitative band identification | Qualitative | Insufficient | B-scan | Eccentricity-specific loci | Visibility (%) | None |
| Griffin et al. (60) | EZ reflectivity | EZ reflectivity peak (no explicit inner/outer band definition) | Not interface-defined | Partial | B-scan | Pixel-level ROIs | Normalized intensity | EZ ÷ IPL |
| Hanna et al. (61) | Photoreceptor (PR) layer | Inner/outer segment junction (device-defined) | RPE segmentation line | Partial | Volumetric | ETDRS central | Thickness | Paired change vs. baseline |
| Hanna et al. (61) | ONL thickness | Device-defined ONL boundary | Device-defined ONL boundary | Partial | Volumetric | ETDRS central | Thickness | Paired change vs. baseline |
| Hanna et al. (61) | Sub-RPE thickness | RPE | Bruch’s membrane (BM) | Partial | Volumetric | ETDRS central | Thickness | Paired change vs. baseline |
| Heckenlaible et al. (62) | OS thickness | EZ | IZ | Partial | Volumetric | ETDRS subfields | Thickness | Coefficient of variation |
| Heckenlaible et al. (62) | EZ thickness | Algorithm-defined ELM–EZ interface | Algorithm-defined EZ–IZ interface | Partial | Volumetric | ETDRS subfields | Thickness | Mean reflectivity |
| Heckenlaible et al. (62) | EZ reflectivity | EZ band (reflectivity-based) | Not thickness-defined | Partial | Volumetric | ETDRS subfields | Reflectivity | Internal normalisation |
| Heiferman et al. (63) | SDD presence | Slab above RPE (manually positioned) | Slab below ELM | Insufficient | En face + volumetric | Lesion-centric | Counts; distance metrics | None |
| Ho et al. (64) | EZ absence | Qualitative EZ band presence | Qualitative absence | Insufficient | B-scan + perimetry | Pointwise loci | Binary + sensitivity | None |
| Ho et al. (64) | RPE disruption | Qualitative RPE morphology | Qualitative | Insufficient | B-scan + perimetry | Pointwise loci | Binary + sensitivity | None |
| Hong et al. (65) | ONL thickness | OPL | ELM | Full | Volumetric | Macular ROIs | Thickness | None |
| Hong et al. (65) | EZ degeneration (GA component) | Qualitative EZ loss | Qualitative | Full | Volumetric | Macular ROIs | Binary | None |
| Itoh et al. (66) | EZ–RPE thickness | EZ segmentation line (algorithm-identified) | RPE “floor” segmentation line | Partial | Volumetric + en face | Macula-wide | Volume; area | EZ–RPE ≤ 20 μm |
| Itoh et al. (66) | EZ loss area | EZ absent relative to RPE | Not thickness-defined | Partial | Volumetric + en face | Macula-wide | Area | EZ–RPE ≤ 20 μm |
| Kalra et al. (67) | EZ + RPE loss concurrence | EZ segmentation line | RPE segmentation line | Partial | B-scan + en face | Whole lesion | Area | CAM-aligned HT thresholds |
| Kalra et al. (67) | Hypertransmission defect | RPE attenuation region | BM | Partial | B-scan + en face | Whole lesion | Area | CAM-aligned HT thresholds |
| Kalra et al. (68) | EZ At-Risk area | EZ segmentation line | RPE segmentation line | Partial | Volumetric | Macula-wide | Area (%) | EZ–RPE ≤ 10 μm |
| Kar et al. (69) | EZ–RPE texture compartment | EZ segmentation line | RPE segmentation line | Partial | Volumetric | Central macula | Radiomics | Z-score standardization |
| Kar et al. (69) | Sub-RPE fractal features | RPE | BM | Partial | Volumetric | Central macula | Texture features | Z-score standardisation |
| Liermann et al. (70) | rEZR (EZ/ELM ratio) | EZ reflectivity peak | ELM reflectivity peak | Partial | Raw B-scan | Central ETDRS | Ratio | Internal reflectivity normalization |
| Mahmoudi et al. (71) | EZ disruption width | EZ band interruption | EZ band reappearance | Insufficient | B-scan | Lesion margins | Length Length |
None |
| Mahmoudi et al. (71) | ELM disruption width | ELM band interruption | ELM band reappearance | Insufficient | B-scan | Lesion margins | Length Length |
None |
| Mahmoudi et al. (71) | Hypertransmission width | Hypertransmission start | Hypertransmission end | Insufficient | B-scan | Lesion margins | Length Length |
None |
| Mai et al. (72) | EZ loss area | EZ segmentation line | IZ outer boundary | Partial | Volumetric | Whole lesion | Area | DL probability mask |
| Mai et al. (72) | RPE loss area | RPE segmentation line | Not thickness-defined | Partial | Volumetric | Whole lesion | Area | DL probability mask |
| Mai et al. (73) | EZ thickness | Top of EZ (algorithm-defined) | Outer boundary of IZ | Partial | Volumetric | Lesion-centric | Thickness Ratio |
EZ ≤ 4 μm |
| Mai et al. (73) | EZ/RPE loss ratio | EZ loss map | RPE loss map | Partial | Volumetric | Lesion-centric | Thickness Ratio |
Quartile stratification |
| Morelle et al. (74) | EZ height map | EZ predicted height surface (CNN) | RPE predicted surface | Partial | Volumetric | Macula-wide | Height Volume |
None |
| Morelle et al. (74) | Drusen volume | RPE predicted surface | BM predicted surface | Partial | Volumetric | Macula-wide | Height Volume |
None |
| Müller et al. (75) | EZ loss | Qualitative EZ absence | Qualitative | Insufficient | B-scan | ETDRS grid | Binary | None |
| Müller et al. (75) | RPE loss | Qualitative RPE absence | Qualitative | Insufficient | B-scan | ETDRS grid | Binary | None |
| Pfau et al., (80) (IOVS) | Residual HFL + ONL within GA | OPL/ONL boundary (structural identification at stimulus loci) | External limiting membrane (ELM) | Insufficient | Volumetric | Intra-lesional loci | Thickness (presence/absence persistence) | None |
| Pfau et al. (80) (IOVS) | ELM descent | ELM band position | Bruch’s membrane (BM) reference | Insufficient | Volumetric | Intra-lesional loci | Positional classification | None |
| Pfau et al. (80) (AJO) | ONL thickness (incl. HFL) | OPL/ONL boundary | ELM | Full | Volumetric | GA contour lines | Thickness | Eccentricity-matched norms |
| Pfau et al. (80) (AJO) | Inner segment (IS) thickness | ELM | EZ | Full | Volumetric | GA contour lines | Thickness | Eccentricity-matched norms |
| Pfau et al., (80) (AJO) | Outer segment (OS) thickness | EZ | IZ | Full | Volumetric | GA contour lines | Thickness | Eccentricity-matched norms |
| Pfau et al. (80) (AJO) | RPEDC thickness | Inner RPE boundary | Bruch’s membrane (BM) | Full | Volumetric | GA contour lines | Thickness | Eccentricity-matched norms |
| Pfau et al. (78) (JAMA Ophthalmol) | ONL thickness | Algorithm-defined ONL compartment | Algorithm-defined ONL compartment | Partial | Volumetric | GA contour lines | Thickness | Eccentricity-normalised |
| Pfau et al. (78) (JAMA Ophthalmol) | IS thickness | Algorithm-defined IS compartment | Algorithm-defined IS compartment | Partial | Volumetric | GA contour lines | Thickness | Eccentricity-normalised |
| Pfau et al. (78) (JAMA Ophthalmol) | OS thickness | Algorithm-defined OS compartment | Algorithm-defined OS compartment | Partial | Volumetric | GA contour lines | Thickness | Eccentricity-normalised |
| Pfau et al. (78) (JAMA Ophthalmol) | EZ-loss distance | EZ loss margin | GA edge | Partial | Volumetric | GA contour lines | Distance | Eccentricity-normalised |
| Pfau et al. (76) (TVST) | ONL variability (SD) | Algorithm-defined ONL boundary | Algorithm-defined ONL boundary | Partial | Volumetric | Macula-wide | Variability (SD) | None |
| Pfau et al. (76) (TVST) | IS thickness variability | Algorithm-defined IS | Algorithm-defined IS | Partial | Volumetric | Macula-wide | Variability (SD) | None |
| Pfau et al. (76) (TVST) | OS thickness variability | Algorithm-defined OS | Algorithm-defined OS | Partial | Volumetric | Macula-wide | Variability (SD) | None |
| Pfau et al. (77) (Sci Rep) | ONL thickness (outside GA) | Algorithm-defined ONL boundary | Algorithm-defined ONL boundary | Partial | Volumetric | 0.43°, 2.58°, 5.16° contours | z-score thickness | Baseline-adjusted |
| Pfau et al. (77) (Sci Rep) | IS thickness | Algorithm-defined IS | Algorithm-defined IS | Partial | Volumetric | 0.43°, 2.58°, 5.16° contours | z-score thickness | Baseline-adjusted |
| Pfau et al. (77) (Sci Rep) | OS thickness | Algorithm-defined OS | Algorithm-defined OS | Partial | Volumetric | 0.43°, 2.58°, 5.16° contours | z-score thickness | Baseline-adjusted |
| Prenner et al. (81) | PR thickness | Outer boundary of IZ | Top of EZ | Full | Volumetric | ETDRS 1/3 mm | Thickness | Device comparison |
| Prenner et al. (81) | RPE thickness | Outer boundary of RPE | Outer boundary of IZ | Full | Volumetric | ETDRS 1/3 mm | Thickness | Device comparison |
| Prenner et al. (81) | ELM loss | ELM band absence | Not thickness-defined | Full | Volumetric | ETDRS 1/3 mm | Binary | Device comparison |
| Qu et al. (82) (RETINA) | Photoreceptor layer thickness | EZ | Inner surface of RPE | Full | En face + volumetric | Lesion margins | Thickness; defect area | None |
| Qu et al. (82) (RETINA) | RPE layer thickness | Inner surface of RPE | Outer RPE/BM complex | Full | En face + volumetric | Lesion margins | Thickness | None |
| Riedl et al. (83) | EZ integrity | Qualitative EZ band continuity | Qualitative | Insufficient | B-scan | ETDRS subfields | % intact | None |
| Riedl et al. (84) (IOVS) | PR thickness | Inner border of EZ | Inner border of RPE | Full | Volumetric | Drusen-centric ROIs | Thickness | None |
| Riedl et al. (84) (IOVS) | ONL thickness | CNN-derived ONL upper boundary | CNN-derived ONL lower boundary | Full | Volumetric | Drusen-centric ROIs | Thickness | None |
| Rogala et al. (85) | PR-layer thickness | Posterior border of RPE | Midpoint of ELM | Partial | Volumetric | Drusen-overlying loci | Thickness | None |
| Rogala et al. (85) | ONL thickness | Posterior OPL | Midpoint of ELM | Partial | Volumetric | Drusen-overlying loci | Thickness | None |
| Russakoff et al. (86) | PR complex thickness | Algorithm-defined PR complex | Algorithm-defined PR complex | Partial | Volumetric + DL | Whole volume | Prediction score | Network normalization |
| Russakoff et al. (86) | RPE–BM thickness | RPE | BM | Partial | Volumetric + DL | Whole volume | Thickness | Network normalization |
| Sadigh et al. (87) | ONL+ thickness | OPL | Outer limiting membrane (OLM) | Full | Volumetric | Drusen-overlying loci | Thickness | None |
| Sadigh et al. (87) | IS + OS thickness | OLM | OS tip/apical RPE interface | Full | Volumetric | Drusen-overlying loci | Thickness | None |
| Saeed et al. (88) | EZ disruption | Qualitative EZ band loss | Qualitative | Insufficient | B-scan | Functional loci | Binary | None |
| Saeed et al. (2025) | ONL thickness | Not explicitly interface-defined | Not explicitly interface-defined | Insufficient | B-scan | Functional loci | Thickness | None |
| Sarici et al. (89) | EZ–RPE thickness | EZ segmentation line | RPE segmentation line | Partial | Volumetric | Central macula | Thickness | AUROC-optimised cut-offs |
| Sarici et al. (89) | RPE–BM thickness | RPE | BM | Partial | Volumetric | Central macula | Thickness | AUROC-optimized cut-offs |
| Saßmannshausen et al. (91) | ONL thickness (z-score) | ONL boundary (device-defined) | ONL boundary (device-defined) | Partial | Volumetric | Functional loci | z-score | Age-matched normalization |
| Saßmannshausen et al. (90) | rEZR | EZ reflectivity peak | ELM reflectivity peak | Partial | Volumetric | ETDRS subfields | Ratio | None |
| Savastano et al. (93) | ONL thickness | Device-defined ONL | Device-defined ONL | Partial | Volumetric | Lesion-centric | Thickness | SRI ≥ 1.5 mm2 |
| Savastano et al. (93) | EZ interruption | Qualitative band loss | Qualitative | Partial | Volumetric | Lesion-centric | Binary | SRI ≥ 1.5 mm2 |
| Sayegh et al. (94) | GA area | Hypertransmission region | GA border on FAF | Partial | Volumetric + FAF | 1-mm and 3-mm zones | Area | Square-root GA growth |
| Schaal et al. (95) | Outer retinal tubulation (ORT) | Tubular structure based on ELM/IS morphology | Tubular structure boundary | Insufficient | B-scan + histology | Lesion margins | Presence; morphology | None |
| Schmidt-Erfurth et al. (96) | EZ loss area | DL-derived EZ loss map (segmentation interface not anatomically specified as inner/outer border) | Not thickness-defined (area map) | Partial | Volumetric | Whole lesion | Area | None |
| Schmidt-Erfurth et al. (96) | RPE loss area | DL-derived RPE loss map (segmentation interface not anatomically specified) | Not thickness-defined (area map) | Partial | Volumetric | Whole lesion | Area | None |
| Schmitz-Valckenberg et al. (97) | Hypertransmission length | Hypertransmission start (caliper-defined) | Hypertransmission end | Partial | B-scan | Lesion margins | Length | None |
| Schmitz-Valckenberg et al. (97) | EZ disruption length | EZ band interruption start | EZ band interruption end | Partial | B-scan | Lesion margins | Length | None |
| Schmitz-Valckenberg et al. (97) | ELM disruption length | ELM band interruption start | ELM band interruption end | Partial | B-scan | Lesion margins | Length | None |
| Schweighofer et al. (98) | MP repeatability vs. SDD | Not interface-defined (SDD presence on OCT; functional repeatability endpoints) | Not interface-defined | Insufficient | Functional + OCT | Test–retest loci | CoR; ICC | Device-specific |
| Song et al. (99) | DL probability of EZ/ELM disruption + fluid features | DL-derived feature maps (EZ/ELM disruption probabilities; no explicit interface borders reported) | Not thickness-defined | Partial | Volumetric + DL | Macular volume | Prediction probability | Feature scaling |
| Steinberg et al. (100) | Partial outer retinal thickness | OPL | RPE | Full | Volumetric | Functional loci | Thickness | None |
| Sulzbacher et al. (101) | Fluid phenotype vs. sensitivity (SRF/IRF/PED) | Not interface-defined (fluid compartment classification) | Not interface-defined | Insufficient | B-scan + MP | Pointwise loci | Sensitivity change | None |
| Inanc Tekin et al. (102) | ONL thickness | OPL | ELM | Full | Volumetric | Central macula | Thickness | None |
| Inanc Tekin et al. (102) | RPE thickness | RPE | BM | Full | Volumetric | Central macula | Thickness | None |
| Tepelus et al. (103) | RPE + OS volume | RPE + OS slab inner boundary (device-defined) | RPE + OS slab outer boundary (device-defined) | Partial | Volumetric | Central 8° | Volume | None |
| Tepelus et al. (103) | ONL volume | ONL slab inner boundary (device-defined) | ONL slab outer boundary (device-defined) | Partial | Volumetric | Central 8° | Volume | None |
| Thiele et al. (104) | rEZR (automated vs. manual) | EZ reflectivity peak | ELM reflectivity peak | Partial | Volumetric | Macular ROIs | Ratio | None |
| Thiele et al. (105) | rEZR (longitudinal decline) | EZ reflectivity peak | ELM reflectivity peak | Partial | Volumetric | ETDRS subfields | Ratio | None |
| Trinh et al. (108) | ONL + HFL thickness deviation | Normative atlas deviation (layer-wise) | Normative atlas deviation (layer-wise) | Full | Volumetric | Macula-wide | Z-score deviation | Normative atlas |
| Trinh et al. (107) | ONL thickness | Layer boundary (segmented) | Layer boundary (segmented) | Full | Volumetric | ETDRS subfields | Thickness | None |
| Trinh et al., 2022 | IS/OS thickness | Layer boundary (segmented) | Layer boundary (segmented) | Full | Volumetric | ETDRS subfields | Thickness | None |
| Trinh et al., 2022 | RPE–BM thickness | RPE | BM | Full | Volumetric | ETDRS subfields | Thickness | None |
| van Romunde et al. (109) | ELM integrity; PR disruption | Qualitative ELM/EZ grading | Qualitative | Insufficient | B-scan | Central fovea | Binary | None |
| Vogl et al. (110) | ONL thinning | Iowa-based ONL boundary (algorithm-defined) | Iowa-based ONL boundary (algorithm-defined) | Partial | Volumetric | ETDRS-style rings + central 3 mm | Thickness | FDR correction |
| Vogl et al. (110) | ORB thinning | Iowa-based ORB compartment boundary | Iowa-based ORB compartment boundary | Partial | Volumetric | ETDRS-style rings + central 3 mm | Thickness | FDR correction |
| Vogl et al. (110) | Choroid thickness | Choroid inner boundary | Choroid-scleral boundary | Partial | Volumetric | ETDRS-style rings + central 3 mm | Thickness | FDR correction |
| von der Emde et al. (111) | ONL thickness | Auto-segmentation boundary (with manual correction; not explicitly mapped to named interfaces) | Auto-segmentation boundary | Partial | Multimodal (OCT + FAF + IR) | MP-aligned loci/macular ROIs | Thickness + multimodal features | Feature scaling |
| Wang et al. (112) | Layer thickness (ONL/PR/RPE etc.) | Manually segmented layer interfaces (study-specific) | Manually segmented layer interfaces | Full | Multimodal | Lesion-/quartile-based ROIs | Thickness + spatial correlation | FAF quartile mapping; intensity trimming |
| Weber et al. (113) | SDD lesion ROIs (FLIO metrics + OCT confirmation) | OCT-confirmed SDD region (ROI-based; not interface thickness) | ROI-based | Partial | Multimodal (FLIO + OCT) | Lesion ROIs | FLIO lifetime metrics + phenotype | Device-/software-specific fitting; ROI QC |
| Woronkowicz et al. (114) | En-face EZ/ELM loss area mapping | ELM segmentation line (multilayer segmentation) | EZ segmentation line/loss map definition | Full | En face + volumetric | ETDRS-centred analysis | Area (loss maps) | None explicitly stated |
| Wu et al. (116) | Complete ELM/EZ/RPE loss area (band-loss endpoints) | DL-derived band-loss maps (ELM/EZ/RPE; “complete loss” endpoint defined per band) | Not thickness-defined (area map) | Full | Volumetric | Sector-based regions | Area | Complete loss operationalised as ≤ 5 μm |
| Wu et al. (115) | Seven early atrophy OCT features (manual) | Manual feature measurement start (caliper-defined) | Manual feature measurement end | Full | B-scan | Lesion-focused | Length/width/ presence | Standardized reader rules + adjudication |
| Yang et al. (117) | Drusen morphology + overlying RPE/EZ integrity (categorical) | Qualitative grading (HEYEX) | Qualitative grading | Insufficient | B-scan | Macular ROIs | Ordinal/categorical | Categorical scales |
| Yordi et al. (120) | BLD; EZ attenuation; CST; SRF/IRF; SHRM volume | ML segmentation of layers + fluid compartments (interfaces not all anatomically specified in text) | Compartment-specific segmentation boundaries | Partial | Volumetric | Macular volume | % attenuation; thickness; fluid volumes | QC + exclusions |
| Yordi et al. (119) (J Pers Med) | EZ–RPE thickness | EZ segmentation line (DL + expert review) | RPE segmentation line | Partial | Volumetric | Macular ROIs | Thickness; % attenuation; intensity | Standardized QC; exclusions |
| Yordi et al. (119) (J Pers Med) | EZ attenuation (%) | EZ thickness-derived attenuation map | Not thickness-defined (percentage metric) | Partial | Volumetric | Macular ROIs | % attenuation | Standardised QC; exclusions |
| Yordi et al. (119) (J Pers Med) | EZ intensity | EZ band intensity ROI | Not thickness-defined | Partial | Volumetric | Macular ROIs | Intensity index | Standardized QC; exclusions |
| Yordi et al. (118) (Ophth Retina) | ML thickness maps + fluid volumes + volatility indices | ML layer segmentation boundaries (Cleveland Clinic; expert verification) | ML layer segmentation boundaries | Partial | Volumetric | Whole volume | Thickness; volume; volatility | Frame-by-frame verification; exclusions |
| Yoshida et al. (121) | EZ and RPE thickness maps; GA prediction | DL-derived EZ segmentation line | DL-derived RPE segmentation line/BM reference (model-dependent) | Partial | Volumetric + modelling | Whole volume | Prediction performance (r2 etc.) | Normalization/ downsampling |
| Zhuang et al. (122) | 3D impairment volumes (EZ/ELM/ONL) | DL-derived impairment boundary (per layer) | Not thickness-defined (impairment map/volume) | Partial | Volumetric | Macular volume | Area/volume of impairment | Standardized QC of maps |
Boundary Specification Adequacy was classified as: Full – Explicit anterior and posterior anatomical interfaces are clearly defined using named retinal structures (e.g., ELM–EZ, EZ–IZ, RPE–BM), allowing independent methodological replication. Partial – Boundaries are segmentation-line–based, device-defined, slab-offset–based, or composite compartments where anterior and/or posterior anatomical interfaces are implied but not explicitly defined in anatomical consensus terminology. Insufficient – A structural term is used without explicit specification of its anterior and posterior anatomical borders, or assessment is qualitative (e.g., integrity/disruption grading) without reproducible interface definition. AC1, Gwet’s agreement coefficient; AI, artificial intelligence; AMD, age-related macular degeneration; ART, automatic real-time (OCT image averaging); AUROC, area under the receiver operating characteristic curve; BCVA, best-corrected visual acuity; BLD, bacillary layer detachment; BM, Bruch’s membrane; CAM, Classification of Atrophy Meeting; CE, Conformité Européenne; CNN, convolutional neural network; CoR, coefficient of repeatability; CST, central subfield thickness; DL, deep learning; ELM, external limiting membrane; ETDRS, Early Treatment Diabetic Retinopathy Study; EZ, ellipsoid zone; EZL, ellipsoid zone loss; FAF, fundus autofluorescence; FCP, fundus-controlled perimetry; FLIO, fluorescence lifetime imaging ophthalmoscopy; GA, geographic atrophy; GLD, greatest linear dimension; HFL, Henle fiber layer; HRF, hyperreflective foci; HT, hypertransmission; ICC, intraclass correlation coefficient; iRORA, incomplete retinal pigment epithelium and outer retinal atrophy; IRF, intraretinal fluid; IS, inner segment; IZ, interdigitation zone; LLVA, low-luminance visual acuity; MAIA, Macular Integrity Assessment; ML, machine learning; MNV, macular neovascularisation; OCT, optical coherence tomography; OPL, outer plexiform layer; ORB, outer retinal bands; ORL, outer retinal layer; ORT, outer retinal tubulation; OS, outer segment; PED, pigment epithelial detachment; PR, photoreceptor; QC, quality control; RORA, retinal pigment epithelium and outer retinal atrophy; RPD, reticular pseudodrusen; RPE, retinal pigment epithelium; RMDA, rod-mediated dark adaptation; ROI, region of interest; SDD, subretinal drusenoid deposits; SD-OCT, spectral-domain optical coherence tomography; SHRM, subretinal hyperreflective material; SRF, subretinal fluid; VA, visual acuity. This table summarizes the technical measurement parameters underpinning OCT-derived photoreceptor biomarkers in AMD, including spatial scale, segmentation boundaries, thresholding logic, normalization strategies, and analytic domain. These parameters govern reproducibility, comparability, and trial readiness but are often inconsistently reported in primary studies.
Particular attention was paid to the extraction of phenotypic disease features with established biological relevance. These included drusen morphology and subtype, the presence or absence of SDD, and MNV subtype (types 1–3), where applicable. However, phenotypic stratification was frequently incomplete or absent across included studies. Key disease-defining characteristics were often inconsistently reported or not specified at all, despite substantial evidence that these features are associated with divergent biological mechanisms, structural progression patterns, and prognostic trajectories.
Drusen subtype and composition have been shown to differentially associate with retinal pigment epithelium dysfunction and photoreceptor degeneration, while SDD represents a topographically and pathophysiologically distinct entity linked to choroidal insufficiency and preferential outer retinal involvement (28–30). Similarly, MNV subtype is associated with differing natural histories, treatment responses, and risks of photoreceptor disruption. The inconsistent reporting of these phenotypes limited the feasibility of biologically meaningful subgroup analyses and may have contributed to heterogeneity in pooled estimates. Where phenotype-resolved data were available, these studies were analyzed separately; however, the small number of such studies precluded formal meta-regression.
2.6. Statistical analysis
Owing to substantial heterogeneity in segmentation boundaries, threshold definitions, spatial sampling frameworks, disease phenotype, and reported outcome metrics, formal quantitative meta-analysis of structural photoreceptor thickness outcomes was not performed.
Instead, findings were synthesized using a structured narrative approach with quantitative categorization of methodological variability. Operational definitions, segmentation boundaries, thresholding rules, region-of-interest strategies, and reflectivity normalization approaches were extracted and grouped into predefined anatomical and methodological domains.
Where reliability or agreement metrics [e.g., intraclass correlation coefficients (ICC), kappa statistics, and correlation coefficients] were reported, these were summarized descriptively. No pooling of effect sizes was undertaken due to differences in statistical definitions, segmentation protocols, and disease context.
Frequencies and proportions were calculated to characterize reporting completeness, boundary specification adequacy, and construct-level variability across studies.
2.7. Structured methodological appraisal
Although a formal risk-of-bias instrument was not applied, as no validated tool exists for the heterogeneous, construct-mapping aims of this scoping review, we conducted a structured appraisal of methodological rigor across five prespecified domains directly relevant to biomarker validity: (1) adequacy of anatomical boundary specification (full/partial/insufficient) (Table 1); (2) reliability-evidence type (formally reported vs. inferred from prior validation) (Table 2); (3) completeness of phenotypic reporting (drusen subtype, SDD/RPD status, MNV subtype); (4) specification of region-of-interest and topographic sampling; and (5) segmentation oversight and adjudication (Supplementary Table S2; summarized in Table 3). Across the 94 studies, boundaries were fully specified in 41 (44%), partially in 32 (34%), and insufficiently in 21 (22%); formal in-study reliability statistics were reported in 18 (19%), with the remainder relying on inferred reliability from previously validated pipelines. This structured appraisal provides a transparent, study-level signal of methodological rigor that contextualizes the reliability, biological-validity, and trial-readiness conclusions drawn in this review.
TABLE 2.
Reliability evidence supporting trial readiness of OCT-derived photoreceptor biomarkers in AMD.
| Study | Biomarker(s)/feature(s) | Reliability evidence type | Inter-grader (reported) | Intra-grader/test–retest (reported) | Validation/ground truth anchor | Trial-readiness interpretation |
|---|---|---|---|---|---|---|
| Abraham et al. (31) | EZ–RPE; ONL–RPE; EZ defect | ◇ Inferred | NR | NR | Expert QC + prior validated segmentation/DL | Robust pipeline used, but reliability not quantified in-study |
| Bell et al. (32) | ILM–RPE; EZ–RPE; RPE–BM | • Reported | ICC 0.965–0.999 (layer-dependent) | NR | Consensus segmentation by senior certified readers | Excellent reproducibility; automation ≈ manual performance |
| Birner et al. (33) | EZ/ONL + drusen/HRF/SDD (DL + expert review) | ◇ Inferred | NR | NR | Expert verification of all SDD | High-fidelity annotation workflow; no ICC/Dice provided |
| Birner et al. (34) | EZL/RPEL/EZT + morphometrics | ◇ Inferred | NR | NR | Prior-validated DL + scan-level QC | Reliability supported by validated DL + QC; not reported numerically |
| Bogunović et al. (35) | Drusen metrics; ONL/ORB; HRF | ◇ Inferred | NR | NR | Iowa algorithms + HRF training set + expert checks | Strong methodological validation; no formal ICC/Dice reported |
| Borrelli et al. (36) | EZ loss/OS volume; ONL thickness | • Reported | ICC (EZ) = 0.911; ICC (OS) = 0.925 | NR | Manual QC review | High repeatability for volumetric EZ/OS quantification |
| Borrelli et al. (37) | EZ reflectivity; CC FD% | ◇ Inferred | NR (prior “excellent agreement” cited) | NR | Manual reference segmentations (prior) | Automated reflectivity stable; not re-quantified here |
| Brandl et al. (17) | ONL; PR IS/OS; RPE/BrM | ◇ Inferred (negative signal) | NR (qualitative: frequent corrections) | NR | Manual corrections used as reference | Autosegmentation error-prone in AMD; manual review essential |
| Carvajal et al. (38) | HRF; RPD; iRORA; cRORA | • Reported | AC1: HRF 0.88→0.92; RPD 0.82→0.89; iRORA 0.99; cRORA 0.98–0.99 | NR | CAM criteria + morphology definitions | Near-perfect agreement for atrophy constructs; subtle features improved with structured scoring |
| Cedro et al. (39) | cRORA area; √ER; ELM/IS-OS scores | ◇ Inferred | NR | NR | CAM criteria + OCT↔FAF comparison | Cross-modal agreement supports validity; reliability stats not stated |
| Cheung et al. (40) | RPE/EZ sinuosity; RPE/EZ continuity | ◇ Inferred | NR | NR | Algorithmic segmentation + manual correction + adjudication | Reliability supported by adjudication workflow; metrics suitable for progression modeling, but no numeric reproducibility |
| Choi et al. (41) | IHRF, SDD, hDC, drusen volume; iRORA/cRORA | ◇ Inferred | NR | NR | Reading-center grading; CAM definitions applied | Central grading supports internal validity; reproducibility not quantified in-paper |
| Cicinelli et al. (42) | ONL/ORL/DLS thickness; GA area (fovea-sparing GA) | • Reported | “Not reported numerically except subset ICC” | ICC 0.95–0.98(subset) | Expert adjudication + CAM criteria; OCT–FAF alignment validation | Thickness measures appear highly repeatable; qualitative features rely on adjudication |
| Clemens et al. (43) | dPED morphology score incl. EZ | • Reported (qualitative/BA) | “Good agreement; minimal disagreement” (BA) | NR | Manual OCT + IR review | Composite morphological scoring reproducible |
| Corbelli et al. (44) | GA area (FAF/en-face OCT/OCTA slabs) | • Reported | ICC 0.986–0.999 (modalities) | ICC 0.995–0.999 | Manual outlining; FAF reference | Near-perfect GA area reliability across modalities |
| Corvi et al. (45) | iRORA/cRORA; hyperTDs | • Reported (agreement) | cRORA 97.6% agreement; iRORA 47.6% | NR | CAM + hyperTD GLD ≥ 250 μm | cRORA robust; iRORA challenging (definition + spacing constraints) |
| Coulibaly et al. (46) | RPEL; ELML; EZL (DL) | ◇ Inferred | NR | NR | FILLY trial masks + expert correction | DL segmentation positioned for trial use; no ICC reported |
| Ehlers et al. (47) | OCT-GA vs. FAF-GA | • Reported (cross-modal concordance) | r≈0.92–0.93; mean Δ−0.17 to + 0.11 mm2 | NR | FAF/OCT cross-validation + adjudication | OCT-GA robust and equivalent to FAF; endpoint-ready |
| Erb et al. (48) | MTII; EZII; GA area | • Reported (agreement ranges) | FAF mean Δ 0.00–0.07 mm2; OCT mean Δ 0.08–0.52 mm2 | NR | Dual graders + senior adjudication; CAM criteria | Strong reproducibility for segmentation-heavy indices |
| Etheridge et al. (49) | Layer thickness (incl. ONL) | ◇ Inferred | NR | NR | Proprietary segmentation + manual correction | Robust QC, but no ICC given |
| Farinha et al. (50) | 7 layers + PRL | ◇ Inferred | NR | NR | Full manual correction + senior QC | Reading-center grade workflow; reliability implied |
| Fasih-Ahmad et al. (51) | EZ/IZ area and thickness (DL + corrections) | ◇ Inferred | NR | NR | Validated algorithm + multi-reader corrections | Multi-grader correction implies high reliability; not quantified |
| Flores et al. (52) | iRORA; EZ; HRF; drusen | • Reported (agreement %) | > 90% agreement (selected features) | NR | Two masked graders + consensus | High reproducibility for manual feature grading |
| Flynn et al. (53) | EZ disruption; SDD presence | ◇ Inferred | NR | NR | Manual OCT grading at predefined functional loci | Structural grading stable for structure–function analysis; no formal reproducibility statistics |
| Fragiotta et al. (54) | ONL thickness; ORL thickness | ◇ Inferred | NR | NR | Automated segmentation with manual correction; longitudinal consistency | Thickness metrics appear stable under corrected workflow; ICC not reported |
| Frank-Publig et al. (55) | Outer retinal band thickness/loss areas; SDDs (High-Res vs. Spectralis) | ◇ Inferred | NR (cites prior improved agreement) | Prior benchmarks: mean abs error ∼1.7–3.5 μm (band-dependent) | Histology-based definitions (Project MACULA) + prior segmentation benchmarks | High-Res OCT improves boundary clarity → likely higher measurement reliability |
| Futterknecht et al. (56) | Focal lesion detection; lesion-targeted MP alignment | ◇ Inferred | NR | NR | Alignment ground truth: mean offset 0.75° (∼218 μm) | Targeting/registration accuracy strong; functional repeatability remains lesion/type dependent |
| Gallagher et al. (57) | Retinal layer thickness (incl. ONL/OSL/RPE); GA hypertransmission length | ◇ Inferred | NR | NR | Prior external validation of segmentation algorithm; internal repeated alignment | Reliability supported by validated segmentation; outer retinal biological variability remains limiting factor |
| Ghoshal et al. (58) | ONL/RPE/ORT thickness and volume | • Reported | ICC RT 0.98; ORT 0.75; ONLT 0.92; RPET 0.79 (etc.) | NR | Reader agreement | ONL robust; some outer layers more variable |
| Goerdt et al. (59) | 28 retinal bands (HR-OCT) | • Reported | NR | κ inner 0.54–0.88; outer 0.67–0.83 | Histology/EM support | Repeatable band localization; some biological visibility limits |
| Griffin et al. (60) | EZ reflectivity; ROI coding | • Reported | NR | ICC (EZ refl) = 0.96; κ(ROI) = 0.74 | Internal consistency | High repeatability for reflectivity-based measures |
| Hanna et al. (61) | 7 layer thickness (SS-OCT) | • Reported | ICC 0.94 | NR | Manual comparison | Automated thickness mapping reliable (thin layers cautioned) |
| Heckenlaible et al. (62) | 11 retinal layer thickness/variability/reflectivity | ◇ Inferred | NR | NR | Iowa algorithms (externally validated) + manual review/corrections | Considered accurate under established algorithmic validation; no in-study ICC/κ reported |
| Heiferman et al. (63) | RPD/SDD identification | • Reported | ICC 0.96 | NR | Manual ROI analysis | Strong reliability for RPD; semi-automated SDD reproducible |
| Ho et al. (64) | Tablet retinal sensitivity (PsyPad) + OCT structural mapping | • Reported | NR | CoR ∼12.3 dB (nAMD), 10.2 dB (at-risk); improves after excluding poor performers | Visual validation of OCT structure–function mapping | Functional tool repeatability quantified; OCT grading reproducibility not reported |
| Hong et al. (65) | SVC/DVC VD; GA size | • Reported | ICC SVC 0.813; DVC 0.891; GA 0.855 | NR | Structural OCT + FAF delineation | Good–excellent reproducibility for quantitative OCTA/OCT metrics |
| Itoh et al. (66) | EZ volume/EZ–RPE | • Reported (test–retest) | NR | r = 0.82 for EZ volume (test–retest) | Manual segmentation check | Stable over time with QC |
| Kalra et al. (67) (J Pers Med) | GA/HT + multilayer (EZ/RPE/BM) | • Reported | ICC 0.88 (B-scan); 0.95 (en-face) | NR | Expert-corrected multilayer ground truth | Excellent agreement; strong trial-readiness for automated maps |
| Kalra et al. (68) (Diagnostics) | EZ-At-Risk; GA; bands | • Reported | ICC 0.83 | NR | Triple-reader QC + adjudication | High precision, device-agnostic performance |
| Kar et al. (69) | EZ–RPE texture; sub-RPE shape metrics | ◇ Inferred | NR | NR | ML feature stability across cross-validation | Reliability inferred from stable predictive performance rather than segmentation agreement |
| Liermann et al. (70) | rEZR (EZ peak reflectivity/ELM peak reflectivity) | ◇ Inferred | NR | NR | Reading-center SOPs (GRADE Bonn) + prior validated automated peak-detection/segmentation + QC exclusions | Strong procedural reliability (RC + validated automation), but no in-paper reproducibility stats → moderate trial readiness |
| Mahmoudi et al. (71) | CAM features (HR-OCT vs. Std) | • Reported | HR-OCT ICC 0.915–0.997 vs. Std 0.518–0.601; AC1 HR 0.88 vs. Std 0.82 | NR | Senior adjudication + training set | HR-OCT materially improves reliability for CAM features |
| Mai et al. (72) | Auto RPE/EZ loss vs. FAF GA | • Reported (cross-modal) | r 0.96–0.97 | NR | FAF manual GA gold standard | OCT automation closely matches FAF; EZ extends beyond RPE loss |
| Mai et al. (73) | EZ/RPE loss ratio; EZ loss area; RPE loss area | ◇ Inferred | NR | NR | Validated DL segmentation (device-specific) applied to phase III trial imaging + FAF/RC GA definition | Trial-embedded scalable endpoint, but reproducibility not reported in-paper → moderate–high procedural readiness |
| Morelle et al. (74) | Drusen/layer height (algorithm vs. expert) | • Reported | Dice (drusen) 0.62–0.71 (reader-dependent) | NR | Expert manual layers | Moderate overlap; reflects task difficulty + reader variability |
| Müller et al. (75) | 10 OCT biomarkers incl. EZ/RPE loss | • Reported | κ 0.160–0.823; ICC 0.527–0.972; Dice 0.539–0.764 | NR | Multi-reader annotation | Reliability heterogeneous; EZ/RPE loss and HRF less reliable than SRF/PED/HT |
| Pfau et al. (8) | Junctional phenotype class | • Reported | κ 0.77 | NR | 2-grader consensus | High reproducibility for phenotype classification |
| Pfau et al. (79) (AJO) | ONL thickness + multimodal features (GA) | ◇ Inferred | “Manual segmentation corrected by two readers (no κ)” | NR | FCP function as anchor | Reliability inferred from dual-reader corrected segmentation; supports modeling but lacks numeric reproducibility |
| Pfau et al. (78) (JAMA) | DL multilayer + GA maps | • Reported | Dice 0.82 (95% CI 0.80–0.85) | NR | Expert manual annotations | Human-level agreement; supports endpoint extraction at scale |
| Pfau et al. (76) (TVST) | OCT thickness/reflectivity features (nAMD) | ◇ Inferred | NR (“built on earlier validated segmentation”) | NR | Nested cross-validation; prediction MAE reported | Endpoint features operationally stable; reliability not stated as ICC/κ/Dice |
| Pfau et al. (77) | z-standardized ONL/IS/OS; GA trial context | ◇ Inferred | NR | NR | Manual + FAF masks (trial-scale DL segmentation) | Trial-scale deployment suggests robustness; explicit reproducibility not reported |
| Prenner et al. (81) | RPE/PR thickness; integrity loss (High-Res vs. Spectralis; nAMD) | ◇ Inferred | NR (single expert performed manual corrections/annotations) | NR | Expert annotation + validated segmentation algorithm | Improved boundary visibility reduces ambiguity; reproducibility not quantified |
| Qu et al. (82) | RPE vs. PR defect areas; junctional type | ◇ Inferred | NR (“described as high”; dual grading + adjudication) | NR | Manual segmentation (3D-OCTOR) + adjudication | High-confidence manual framework; suitable for phenotyping; lacks numeric reliability |
| Riedl et al. (83) | EZ integrity (manual); IRC/SRF/PED (AI) | ◇ Inferred | NR | NR | Expert manual EZ annotation; validated CNN for fluid; Iowa PED algorithm | High internal consistency via hybrid manual + validated AI; reproducibility not quantified |
| Riedl et al. (84) | PR thickness/ONL/drusen/HT (AI) + OPL subsidence (manual) | ◇ Inferred | NR (OPL graded by 2 graders) | NR | Previously validated DL models + manual QC | Robust pipeline with manual confirmation; no ICC/κ reported for key outputs |
| Rogala et al. (85) | PR/RPE thickness; ONL thickness; PR thickness above drusen | ◇ Inferred | NR | NR | Manual measurements with subset second-clinician verification + standardized Spectralis acquisition | Manual caliper measures with limited scalability and no stats → low–moderate readiness |
| Russakoff et al. (86) | PR/ONL thickness inputs; latent PR/EZ features (CNN) | ◇ Inferred | NR | NR | Automated segmentation pipeline with expert verification + standardized preprocessing; outcome anchor = FA-confirmed nAMD | Procedurally robust ML pipeline, but no reproducibility stats and partly latent features → moderate methodological readiness |
| Sadigh et al. (87) | ONL + (incl HFL); IS + OS thickness; PR thickness over/paradrusen | ◇ Inferred | NR | NR | Manual segmentation using published layer definitions + normative comparison; authors note reliability not assessed | Informative biology but manual, no reproducibility stats → low–moderate readiness |
| Saeed et al. (2025) | ONL thickness; ELM/EZ disruption; atrophy-associated PR features | ◇ Inferred | NR | NR | CAM-based feature definitions + high-density SS-OCT QC; functional anchor = repeated microperimetry | Strong definitions + QC, but single-grader workflow and no stats → moderate readiness |
| Sarici et al. (89) | EZ–RPE thickness; partial/total EZ attenuation; RPE–BM thickness | ◇ Inferred | NR | NR | ML-enabled multilayer segmentation + dual expert review/correction; outcome anchor = subfoveal GA conversion | Scalable quantitative EZ metrics with expert correction, but no ICC/κ/Dice → moderate–high procedural readiness |
| Saßmannshausen et al. (91) | ONL; PR (ELM–BM); PR-segments (ELM–RPE); RPEDC | ◇ Inferred | NR | NR | Automated segmentation with full-volume manual correction + INOCT definitions + standardized Spectralis acquisition | Methodologically rigorous, but reproducibility not quantified → moderate readiness |
| Saßmannshausen et al. (90) (MACUSTAR) | rEZR (test–retest) | • Reported | NR | ICC overall 0.846 (0.809–0.876); stage-stratified ICCs reported | DL training + reader QC | Repeatable multicenter biomarker suitable for trials |
| Saßmannshausen et al. (92) | ONL/IS/OS thickness at HRF + vs. HRF− locations | ◇ Inferred | NR | NR | Full-volume manual correction of segmentation + CAM/INOCT definitions; HRF graded by single experienced reader | Strong segmentation QC, but HRF single-grader + no stats → moderate readiness |
| Savastano et al. (93) | SRI (RORA); ONL; EZ interruption | • Reported | κ > 0.9 for ONL and EZ | NR | QC thresholds + 2 graders + fERG link | Strong reliability for ONL/EZ; SRI automated (minimal variability) |
| Sayegh et al. (94) | Foveal sparing area; OCT-derived GA area (outer retinal/RPE loss) | ◇ Inferred | NR | NR | Vienna Reading Center SOPs + adjudication; standardized Spectralis follow-up mode | RC-grade workflow, but no reproducibility metrics and largely single-reader → moderate readiness |
| Schaal et al. (95) | Outer retinal tubulation (ORT) | • Reported (construct validation) | NR | NR | Direct OCT–histology correlation (light microscopy + TEM) | High biological validity; qualitative feature without reproducibility stats → low endpoint readiness (contextual/enrichment) |
| Schmitz-Valckenberg et al. (97) | Early atrophy features (HT, ELM/EZ, etc.) | • Reported | κ varies widely (HT/ELM moderate; EZ/ONL poor) + BA widths | NR | Senior consensus | Identifies which subtle features are unreliable without stricter definitions |
| Schweighofer et al. (98) | Microperimetry repeatability | • Reported | ICC MP-3 0.869; MAIA 0.848; inter-device 0.841 | CoR values reported | DL-segmented OCT coregistered to MP | MP reliability strong; supports structure–function endpoint linking |
| Song et al. (99) | EZ/ELM + exudation features (AI vs. experts) | • Reported | Mean Dice 0.873; accuracy EZ 0.93; ELM 0.873 | NR | Dual-expert consensus | Excellent algorithmic agreement for key outer-retinal bands |
| Steinberg et al. (100) | Partial outer retinal thickness (OPL outer border → EZ inner border) | ◇ Inferred | NR | NR | Automated segmentation with full-volume manual correction + normative/topographic normalization; functional anchor = FCP | Strong methodological workflow, but no reproducibility stats → moderate readiness |
| Sulzbacher et al. (101) | Morphological OCT tags + ELM/EZ | • Reported | Intergrader agreement 89.5% (range 84.5–94.5%) | NR | Dual-grader certified review | High reproducibility for clinical OCT morphology grading |
| Inanc Tekin et al. (102) | ONL; OPL; RPE thickness | ◇ Inferred | NR | NR | Dual-grader analysis + manual correction of automated segmentation; standardized Spectralis acquisition | Quantitative layers with dual grading, but no ICC/κ→ moderate readiness |
| Tepelus et al. (103) | RPE + OS volume; ONL volume | ◇ Inferred | NR | NR | Automated segmentation with QC inspection; centralized analysis (DIRC); functional anchor = microperimetry | Scalable volumetrics with QC, but no reproducibility stats → moderate readiness |
| Thiele et al. (104) | rEZR (manual vs. automated) | • Reported | Manual CoR 6.3 AU; automated peak-detection 96.8% | Automated “perfect repeatability” stated | Histology-informed band definitions | Automated rEZR extraction highly reproducible for longitudinal use |
| Trinh et al. (108) | ONL + HFL; IS/OS; RPE–BM thickness | ◇ Inferred | NR | NR | Dual-grader full-volume manual correction (ground truth) + standardized Spectralis acquisition + normative anchoring | Very strong procedural reliability, but no ICC/κ/test–retest → moderate readiness |
| Trinh et al. (2022) | ONL + HFL; IS/OS; RPE–BM thickness (high-density sampling) | ◇ Inferred | NR | NR | Dual-grader corrected “ground truth” segmentation + high-density 60 × 60 grid + matched normals | Technically robust and scalable, but reproducibility not quantified → moderate readiness |
| van Romunde et al. (109) | ELM/EZ integrity and multimodal variables | • Reported | κ/ICC 0.69–0.99 for included variables | NR | Masked graders + adjudication threshold | High categorical reliability; excludes variables failing agreement |
| Vogl et al. (110) | ONL/ORB/choroid texture (Cirrus; atlas registration) | ◇ Inferred | “High stability across > 10k scans” (qualitative) | NR | Validated segmentation + registration; clinician-defined conversion anchors | Population-scale extraction stable; reproducibility inferred (not expressed as ICC) |
| von der Emde et al. (111) | ONL thickness; FAF intensity; inferred sensitivity modeling | ◇ Inferred | NR | NR | Microperimetry functional ground truth; manual OCT layer QC | Predictive reliability strong; segmentation reproducibility not reported numerically |
| Wang et al. (112) | Layer thickness (RPE/PR/ONL/choroid) + FAF/NIR correlation | ◇ Inferred | NR | NR | Manual segmentation + strict co-registration | Pixel-level correspondence strong; reproducibility not reported |
| Weber et al. (113) | SDD lesion ROIs (FLIO metrics + OCT confirmation) | ◇ Inferred | NR (single expert grader) | NR | OCT confirmation of SDD; controlled environment ROIs | Lesion-level metrics stable in practice; formal reproducibility not reported |
| Woronkowicz et al. (114) | EZ/ELM loss area (manual mapping) | ◇ Inferred | NR | NR | Human interpretive mapping | Clinical utility shown; reproducibility stats absent |
| Wu et al., 2025 (longitudinal bands) | Area of complete ELM/EZ/RPE loss ( ≤ 5 μm) | • Reported | CoV: EZ 217% < ELM 244% < RPE 397% | NR | CE-marked DL segmentation; validated previously | Quantifies variability in automated band-loss endpoints (important for meta-analysis modeling) |
| Wu et al., 2025 (multicenter reader study) | cRORA feature set incl. EZ/ELM disruption, ONL thinning etc. | • Reported | AC1 0.80–0.88 ( ≥ 500 μm lesions) | NR | 12 readers/6 certified reading centers; functional relevance | Strong trial-readiness: high inter-reader agreement when definitions sized ≥ 500 μm |
| Yang et al., 2021 | EZ damage; RPE damage; drusen reflectivity/homogeneity/shape | • Reported | κ/agreement reported (inter-observer 83.4–95.2%) | Intra-observer agreement 82.7–94.8% | Dual masked graders + adjudication; explicit OCT morphology definitions | Strong reliability for categorical features; useful for enrichment/risk stratification (not quantitative endpoint) |
| Yordi et al. (120) | BLD; EZ attenuation (%0, % ≤ 20 μm); SRF/SHRM metrics | ◇ Inferred | NR | NR | Trial-grade imaging + ML segmentation with masked expert correction; OSPREY phase II | Trial-embedded pipeline, but no ICC/κ/test–retest → high procedural, inferred reliability |
| Yordi et al. (119) (J Pers Med) | EZ attenuation (partial/total); EZ–RPE thickness/volume; EZ intensity index | ◇ Inferred | NR | NR | ML segmentation + layered expert review/QC; standardized acquisition; VA prediction anchor | Strong procedural QC and longitudinal validity, but no reproducibility stats → high procedural, inferred reliability |
| Yordi et al. (118) (Ophthal Retina) | BLD (classic/indeterminate); EZ attenuation; EZ–RPE thickness/volume; fluid volumes | ◇ Inferred | NR (dual-reader adjudicated BLD; no κ/ICC) | NR | Phase III HAWK imaging + ML quantification + adjudication | Phase III embedded and scalable, but no reproducibility stats → high procedural, inferred reliability |
| Yoshida et al. (121) | EZ thickness (iEZ–iRPE); RPE thickness; EZ–RPE maps; EZ/RPE intensity maps | ◇ Inferred | NR | NR | ML segmentation trained on 6,718 manual labels + trial FAF grading anchor (RegionFinder) | Mature trial-grade ML pipeline, but no ICC/κ/test–retest → high procedural, inferred reliability |
| Zhuang et al. (122) | EZ/ELM/ONL impairment areas; avascular SHRM; MNV volume | • Reported | κ > 0.80 (two readers; arbitration if > 10% difference) | NR | Dual masked readers + explicit impairment definitions; OCT + OCTA separation of components | Explicit inter-reader reliability for 3D-derived damage metrics; manual burden limits scalability → moderate–high readiness |
• Reported = explicit reliability statistic(s) provided. ◇ Inferred = reliability supported by reading-center protocols/adjudication/validated algorithms/structured QC, but no statistic reported in that paper. NR, not reported; AC1, Gwet’s agreement coefficient; AMD, age-related macular degeneration; BA, Bland–Altman; BCVA, best-corrected visual acuity; BLD, bacillary layer detachment; BM, Bruch’s membrane; CAM, Classification of Atrophy Meeting; CC, choriocapillaris; CoR, coefficient of repeatability; CoV, coefficient of variation; cRORA, complete retinal pigment epithelium and outer retinal atrophy; CST, central subfield thickness; DL, deep learning; DVC, deep vascular complex; ELM, external limiting membrane; ER, ellipsoid zone–RPE (EZ–RPE) thickness (also termed ellipsoid zone to RPE distance); EZ, ellipsoid zone; EZII, ellipsoid zone integrity index; EZL, ellipsoid zone loss; FAF, fundus autofluorescence; FA, fluorescein angiography; FD%, flow deficit percentage; FCP, fundus-controlled perimetry; GA, geographic atrophy; GLD, greatest linear dimension; HFL, Henle fiber layer; HRF, hyperreflective foci; HT, hypertransmission; ICC, intraclass correlation coefficient; iRORA, incomplete retinal pigment epithelium and outer retinal atrophy; ILM, internal limiting membrane; IRF, intraretinal fluid; IS/OS, inner segment/outer segment; IZ, interdigitation zone; MNV, macular neovascularization; MP, microperimetry; MTII, macular tissue integrity index; nAMD, neovascular age-related macular degeneration; OCT, optical coherence tomography; OCTA, OCT angiography; OPL, outer plexiform layer; ORT, outer retinal tubulation; ONL, outer nuclear layer; PR, photoreceptor; QC, quality control; RC, reading center; rEZR, relative ellipsoid zone reflectivity; RPD, reticular pseudodrusen; RPE, retinal pigment epithelium; RPE–BM, retinal pigment epithelium–Bruch’s membrane complex; RPEL, RPE loss; RPEDC, RPE–drusen complex; RORA, RPE and outer retinal atrophy; SD-OCT, spectral-domain OCT; SDD, subretinal drusenoid deposits; SHRM, subretinal hyperreflective material; SRF, subretinal fluid; SOP, standard operating procedure; SS-OCT, swept-source OCT; SVC, superficial vascular complex; VA, visual acuity.
TABLE 3.
Structured methodological-rigor appraisal of the 94 included studies.
| # | Appraisal domain | Source | Rating categories | Studies, n (%) |
|---|---|---|---|---|
| 1 | Anatomical boundary specification adequacy | Table 1 | Full | 41 (44%) |
| Partial | 32 (34%) | |||
| Insufficient | 21 (22%) | |||
| 2 | Reliability evidence | Table 4 | Formally reported (in-study) | 18 (19%) |
| Inferred from prior validation | 76 (81%) | |||
| 3 | Phenotype reporting completeness | §3.5 | Qualitative appraisal* | Inconsistent |
| 4 | Region-of-interest/topographic specification | §3.3 | ROI geometry specified | 82 (87%) |
| ROI geometry not specified | 12 (13%) | |||
| Eccentricity-/topography-stratified | 29 (31%) | |||
| 5 | Segmentation oversight and adjudication | Supplementary Table S2 | Explicit oversight | 55 (59%) |
| Partial oversight | 25 (27%) | |||
| None/not reported | 14 (15%) |
*Phenotype reporting was appraised qualitatively (§3.5): drusen presence was commonly documented, whereas drusen subtype, subretinal drusenoid deposit (SDD/RPD) status, and macular neovascularization subtype were inconsistently reported, and complete phenotype stratification was rare. A per-study rating (complete/partial/absent) can be provided in Supplementary Table S1. Percentages are of the 94 included studies; ROI, region of interest. Studies were appraised across five prespecified domains relevant to biomarker validity. A formal risk-of-bias instrument was not applied, as none is validated for the construct-mapping aims of a scoping review; this appraisal provides a transparent, study-level signal of methodological rigor.
3. Results
3.1. Study selection and characteristics
The search yielded 571 unique records after de-duplication. Following title and abstract screening, 311 full texts were reviewed, and 94 studies met the inclusion criteria and were synthesized (17, 27, 31–122) (Figure 1). The temporal distribution of publications showed a marked increase after 2020, coinciding with wider adoption of dense volumetric OCT acquisition, en face and three-dimensional analytic approaches, and the maturation of automated and deep-learning–based segmentation pipelines for outer retinal structures.
Included studies ranged from small exploratory cohorts to large observational datasets and trial-linked analyses, encompassing between 12 and 1,847 eyes (median 94; interquartile range 48–186) (Table 1). Most cohorts were derived from North America and Europe and were frequently associated with established academic imaging centers and AMD consortia. Heidelberg Spectralis spectral-domain OCT predominated, particularly in studies aligned with the Classification of Atrophy Meeting (CAM) framework and longitudinal geographic atrophy (GA) analyses, with Zeiss Cirrus and swept-source platforms increasingly represented in later work, especially in studies emphasizing volumetric mapping, cross-device validation, or automated analytics (70, 90). Full study characteristics are provided in Supplementary Table S1.
Disease stages were intentionally heterogeneous (Table 4). Intermediate AMD predominated (47 studies, 50%), followed by geographic atrophy or atrophic AMD including iRORA/cRORA (31, 33%), early AMD (17, 18%), and neovascular AMD (12, 13%); a further four studies (4%) addressed late dry AMD of unspecified stage. Because many cohorts deliberately spanned the AMD continuum, 18 studies (19%) contributed to more than one stage and 15 (16%) included normal or control comparators, so categories are not mutually exclusive. A substantial body of work addressed early and intermediate AMD, often focusing on subclinical outer retinal change and detailed structure–function relationships using microperimetry or dark adaptation testing (33, 53, 91, 100, 103, 110). A large GA-focused literature quantified photoreceptor degeneration within atrophic lesions and at their margins, frequently using CAM-aligned constructs (iRORA and cRORA) or closely related OCT feature definitions (45, 72, 77–80, 82, 97, 112). A smaller but clinically relevant subset examined neovascular AMD, typically in the context of treatment response, disease activity, or structure–function mapping (64, 101, 109, 111, 114, 118, 120, 122). Several studies spanned multiple disease stages to characterize biomarker behavior across the AMD continuum and to model progression risk (35, 52, 68, 69, 86, 89, 96, 121).
TABLE 4.
Distribution of AMD phenotypes across the 94 included studies.
| AMD phenotype/stage | Studies, n | % of 94 studies |
|---|---|---|
| Early AMD | 17 | 18% |
| Intermediate AMD (iAMD) | 47 | 50% |
| Geographic atrophy/atrophic AMD (incl. iRORA, cRORA) | 31 | 33% |
| Neovascular AMD (nAMD) | 12 | 13% |
| Late dry AMD, stage not further specified | 4 | 4% |
| Mixed AMD/non-AMD or unspecified stage | 3 | 3% |
| Studies including normal/control comparators | 15 | 16% |
| Studies spanning > 1 disease stage | 18 | 19% |
Classification based on the AMD Stage/Phenotype field in Supplementary Table S1. Studies spanning multiple stages are counted in each applicable category; counts therefore exceed 94 and percentages exceed 100%. Control and > 1 disease stage rows are descriptive overlays, not mutually exclusive categories. cRORA, complete RPE and outer-retinal atrophy; iRORA, incomplete RPE and outer-retinal atrophy.
The use of the OCT platform reflects real-world clinical research practice. Heidelberg Spectralis was the predominant platform, used in 72 studies (77%), including 60 studies (64%) that relied exclusively on Spectralis and 12 (13%) that combined Spectralis with another OCT device. Zeiss Cirrus was the second most common platform (9%), while other devices (Topcon, RTVue, and prototype systems) each accounted for fewer than 5% of studies (17, 45, 77–80, 94, 97), followed by Zeiss Cirrus and other platforms used for cross-device evaluation or disease-agnostic validation of segmentation outputs (32, 67, 72, 90). Swept-source OCT adoption increased in later studies, particularly where deeper imaging and dense-volume acquisition supported enface/volumetric mapping and more automated workflows (27, 46, 62, 67, 72, 73, 121).
3.2. Axial quantification of photoreceptor compartments
Across the 94 included studies, “photoreceptor integrity” was most commonly inferred from axial thickness measurements of one or more outer retinal compartments. Although terminology varied, the dominant methodological assumption was that the anterior–posterior span of a defined anatomical structure reflects the quantity or preservation of photoreceptor tissue (37, 89). To reduce this ambiguity, we apply standardized terminology throughout this review (Table 5): “integrity” denotes the overarching qualitative construct, “disruption” a categorical loss of band continuity, “attenuation” a partial reduction in reflectivity or thickness, and “loss/absence” the complete absence of a detectable band, with every quantitative metric paired with its explicit boundaries and measurement domain. However, studies differed substantially in which photoreceptor compartment was measured, how its borders were defined, and how loss was operationalized. The measurement parameters underpinning each OCT-derived photoreceptor biomarker, particularly boundary choice, spatial domain, and thresholding, are summarized in Table 1.
TABLE 5.
Standardized terminology for OCT-derived photoreceptor biomarkers.
| Term | Standardized definition | Recommended usage |
|---|---|---|
| EZ integrity | Overarching qualitative construct denoting preservation of the ellipsoid zone band (presence, normal reflectivity, and normal thickness). | Use as a general concept only; not as a measured quantity. Avoid as a synonym for a specific metric. |
| EZ disruption | Categorical, focal or segmental discontinuity of the EZ band; typically continuity-graded. | Use for continuity-based (present/interrupted/absent) assessments; state grading scheme. |
| EZ attenuation | Partial reduction in EZ reflectivity and/or thickness without complete absence. | Use for sub-total signal/thickness reduction; specify whether reflectivity- or thickness-based. |
| EZ loss/EZ absence | Complete absence of a detectable EZ band (e.g., EZ–RPE = 0 μm). | Use for complete loss only; state the threshold/boundary used to define 0. |
| EZ thickness | Axial distance between explicitly defined anterior and posterior borders of the EZ (or EZ-referenced span). | Always state the inner and outer boundaries (e.g., ELM–EZ, EZ–RPE) and the measurement domain. |
| Relative EZ reflectivity (rEZR) | Normalized EZ-band intensity index referenced to a specified internal standard. | State the normalization reference (e.g., ELM-, IPL-, or peak-referenced). |
| ONL thickness | Axial distance from OPL to ELM; proxy for photoreceptor cell-body integrity. | State handling of the Henle fiber layer (included vs. excluded/modeled). |
| ELM integrity/disruption | Continuity of the external limiting membrane band. | Use disruption for categorical continuity grading; pair with EZ/ONL status in advanced disease. |
| Interdigitation zone (IZ) | Hyperreflective band corresponding to outer-segment–RPE apical apposition. | Report visibility/acquisition conditions; treat as emerging biomarker. |
| Composite outer-retinal thickness | Multi-layer axial span combining ≥ 2 photoreceptor compartments (e.g., ELM–RPE, ONL–RPE). | Always specify constituent boundaries; avoid implying single-compartment specificity. |
| iRORA/cRORA | Incomplete/complete RPE and outer-retinal atrophy, per CAM consensus definitions. | Use strictly per CAM; do not use as generic synonyms for EZ/ONL loss. |
CAM, Classification of Atrophy Meeting; ELM, external limiting membrane; EZ, ellipsoid zone; IPL, inner plexiform layer; ONL, outer nuclear layer; OPL, outer plexiform layer; RPE, retinal pigment epithelium.
Under an anatomical framework, axial photoreceptor quantification can be grouped into three principal compartments: (1) inner segment metrics, most commonly derived from the ellipsoid zone (EZ); (2) nuclear layer metrics, typically based on outer nuclear layer (ONL) thickness; and (3) composite outer retinal spans that combine multiple layers within a single measurement.
These findings demonstrate that commonly used terms such as “EZ thickness” and “ONL loss” do not represent single anatomical constructs across the literature. Instead, identical terminology frequently corresponds to distinct segmentation boundaries, thresholding rules, and spatial sampling strategies. This heterogeneity underpins the boundary-dependent nature of axial photoreceptor biomarkers and provides context for the conditional reliability findings reported below. Operational definitions and thresholds used across studies are mapped in Table 6.
TABLE 6.
Evidence map of operational definitions for OCT-derived photoreceptor-layer biomarkers in AMD.
| Study | Biomarker(s) | Operational definition/threshold | Imaging plane | Region of interest/topography | CAM alignment |
|---|---|---|---|---|---|
| Ellipsoid zone (EZ)–based biomarkers | |||||
| Abraham et al. (31) | EZ–RPE thickness; EZ attenuation | Total EZ loss: EZ–RPE = 0 μm; partial loss ≤ 20 μm | Volumetric + en face | ETDRS subfields | Partial |
| Bell et al. (32) | EZ loss | EZ boundary collapsed to RPE (“EZ dropped to RPE”) | B-scan | Central macula | Partial |
| Birner et al. (33) | EZ thickness | EZ thickness between IZ and EZ boundaries | B-scan | 70-μm radius at MP loci | Partial |
| Birner et al. (34) | EZ loss | Loss of EZ–IDZ band at functional loci | B-scan | 70-μm radius at MP loci | Yes |
| Borrelli et al. (36) | EZ area/volume | Manual segmentation of EZ band between ELM and IZ | B-scan | Macular ROIs | No |
| Flynn et al. (53) | EZ integrity category | EZ intact/attenuated/absent (ordinal) | B-scan | Functional test loci | No |
| Griffin et al. (60) | EZ reflectivity | EZ reflectivity normalized to IPL reflectivity | B-scan | Pixel-based ROIs | No |
| Liermann et al. (70) | EZ/ELM reflectivity ratio | rEZR = EZ peak ÷ ELM peak reflectivity | Raw B-scan | Central ETDRS zones | Partial |
| Woronkowicz et al. (114) | EZ-loss area | En-face projection of EZ absence | B-scan → en face | Whole 20° × 20° field | Partial |
| Yordi et al. (120) | EZ attenuation | Partial EZ ≤ 20 μm; total EZ = 0 μm | Volumetric | Whole cube + subfields | Partial |
| Yordi et al. (119) | EZ attenuation/intensity | EZ thickness and intensity normalized to RPE | Volumetric | ETDRS subfields | Partial |
| Zhuang et al. (122) | EZ impairment | EZ absence annotated across serial B-scans | B-scan | 8 × 6 mm cube | Partial |
| Outer nuclear layer (ONL)–based biomarkers | |||||
| Brandl et al. (17) | ONL thickness | Distance between OPL and ELM boundaries | Volumetric | ETDRS 1/3/6-mm rings | Partial |
| Etheridge et al. (49) | ONL thickness | Spectralis-defined OPL→ELM thickness | ETDRS maps | ETDRS grid | No |
| Fragiotta et al. (54) | ONL thickness | OPL outer border to ELM | ETDRS maps | Central 1 mm and 1–3 mm | Partial |
| Ghoshal et al. (58) | ONL thickness/volume | OPL outer border to ELM | Volumetric | Central ETDRS | No |
| Rogala et al. (85) | ONL thickness | ELM to posterior OPL | B-scan | Drusen-centric ROIs | No |
| Sadigh et al. (87) | ONL+ thickness | OPL vitread boundary to ELM | Line scans | 6 × 6 mm raster | No |
| Saßmannshausen et al. (91) | ONL thickness (z-score) | ONL normalized to age-matched controls | Volumetric | 56 functional loci | Partial |
| Thiele et al. (105) | ONL thickness | Automated ONL segmentation over time | Volumetric | ETDRS regions | Partial |
| Yang et al., 2021 | ONL damage | Qualitative ONL disruption grading | B-scan | Drusen-associated ROIs | No |
| External limiting membrane (ELM)–based biomarkers | |||||
| Cedro et al. (39) | ELM integrity score | Ordinal ELM continuity score | B-scan | Central macula | Yes |
| Steinberg et al. (100) | Partial OR thickness | OPL to EZ inner border (adjusted if EZ absent) | Volumetric | MP loci | Partial |
| Sulzbacher et al. (101) | ELM integrity | Intact vs. disrupted ( > 50% interruption) | Volumetric | Pointwise loci | No |
| Wu et al. (2025) | ELM loss | Segmented ELM thickness ≤ 5 μm | Volumetric | Central 5 mm | Yes |
| Photoreceptor reflectivity defects (PRD/isolated EZ loss) | |||||
| Qu et al. (82) | PR defect type | Type 1: PR loss beyond RPE loss | B-scan | GA perimeter | No |
| Inanc Tekin et al. (102) | PR loss pattern | Photoreceptor loss vs. fibrotic scar comparison | B-scan | Lesion-centric | No |
| Composite and derived photoreceptor metrics | |||||
| Cheung et al. (40) | EZ/RPE sinuosity | Band length ÷ BM length (EZ > 1.01) | B-scan | Central macula | Partial |
| Erb et al. (48) | EZ integrity index | % intact EZ within 1- and 3-mm circles | En face | Central ETDRS | Yes |
| Pfau et al. (78) | ONL/IS/OS z-scores | Thickness normalized to eccentricity-matched controls | Volumetric | Contour-based ROIs | Partial |
| Pfau et al. (77) | Photoreceptor z-scores | ONL/IS/OS thickness outside GA margins | En face | Distance-based contours | Partial |
| Yoshida et al. (121) | Continuous PR thickness | EZ-to-RPE continuous thickness (no binary cut-off) | Volumetric | Whole cube | Partial |
| CAM-aligned atrophy and photoreceptor degeneration (iRORA/cRORA) | |||||
| Carvajal et al. (38) | iRORA/cRORA | CAM size thresholds (125–249 μm; ≥ 250 μm) | B-scan | ETDRS grid | Yes |
| Cicinelli et al. (42) | GA with foveal status | GA ≥ 0.049 mm2 with PR degeneration | Radial scans | Central 1 mm | Yes |
| Corvi et al. (45) | iRORA/cRORA | CAM criteria + hyperTD slab | B-scan + en face | 6 × 6 mm | Yes |
| Ehlers et al. (47) | OCT-GA | RPE loss with PR degeneration confirmed vs. FAF | Volumetric | Whole lesion | Yes |
| Kalra et al. (67) | Automated GA | Coincident EZ, RPE and BM loss | Volumetric | 6 × 6 mm | Yes |
| Mai et al. (72) | EZ and RPE loss | EZ ≤ 4 μm; complete RPE attenuation | Volumetric | GA within OCT FOV | Yes |
| Schmitz-Valckenberg et al. (97) | Early atrophy | Longitudinal iRORA/cRORA classification | Volumetric | Central macula | Yes |
| Wu et al. (2025) | Early atrophic lesions | CAM-based grading with reader agreement | Volumetric | 3.5° region | Yes |
AMD, age-related macular degeneration; BM, Bruch’s membrane; CAM, Classification of Atrophy Meetings; cRORA, complete retinal pigment epithelium and outer retinal atrophy; ELM, external limiting membrane; ETDRS, Early Treatment Diabetic Retinopathy Study; EZ, ellipsoid zone; FAF, fundus autofluorescence; GA, geographic atrophy; IZ, interdigitation zone; MP, microperimetry; ONL, outer nuclear layer; OCT, optical coherence tomography; PR, photoreceptor; PRD, photoreceptor reflectivity defect; RPE, retinal pigment epithelium.
3.2.1. Photoreceptor inner segment metrics (EZ-derived)
The most common approach for quantifying photoreceptor inner segment integrity was measuring EZ thickness. In most studies, the axial thickness of the EZ hyperreflective band was used as a surrogate for preservation of inner segment structure, with thinning or absence interpreted as photoreceptor loss or dysfunction (37, 89).
However, substantial variability arose from how the EZ was defined. Some investigations measured thickness strictly between the anterior and posterior borders of the EZ band, whereas others defined spans incorporating adjacent interfaces (e.g., ELM-to-EZ or EZ-to-RPE distances). These represent distinct anatomical assumptions regarding what portion of the photoreceptor complex is being captured. Because the EZ band is thought to correspond primarily to mitochondria-rich inner segments rather than the full photoreceptor unit, interpretation of EZ thickness as total photoreceptor integrity depends critically on consistent boundary definition (15, 16).
Boundary delineation is particularly challenging in diseased maculae. In the presence of drusen, subretinal fluid, intraretinal fluid, subretinal hyperreflective material, or nascent atrophy, outer retinal bands may broaden, attenuate, or partially merge. Under these conditions, small differences in segmentation rules may materially alter measured thickness and shift classification from “attenuated” to “absent.” Inter-reader variability and segmentation ambiguity in AMD have been documented, particularly where layers are thin or poorly demarcated (32, 75).
Beyond thickness, several studies examined relative EZ reflectivity or intensity-normalized indices as potential markers of early inner segment dysfunction (90, 104). Large consortium analyses, including MACUSTAR-linked work, demonstrated stepwise reductions in relative EZ reflectivity with increasing disease severity and associations with functional outcomes (70, 90). However, reflectivity-based metrics are sensitive to acquisition parameters, signal normalization strategy, axial resolution, and post-processing pipelines, limiting direct comparability across platforms (20).
Topographic sampling further influenced interpretation. EZ measurements were reported using ETDRS subfields, central-only measures, parafoveal rings, lesion-centric masks, or microperimetry-aligned loci (33, 90). Given physiological variation in outer retinal thickness across the macula, and evidence that parafoveal regions may demonstrate earlier structural change, differences in spatial sampling constrain cross-study comparisons of absolute values (Table 6).
Collectively, inner segment metrics illustrate how differences in segmentation boundaries, thresholding rules, and spatial reporting materially affect the interpretation of ostensibly similar “EZ thickness” endpoints.
3.2.2. Photoreceptor nuclear layer metrics (ONL-derived)
ONL thickness was widely used as a proxy for photoreceptor cell-body integrity and was generally defined more consistently than EZ-derived metrics. Most studies measured ONL thickness between the OPL and ELM and interpreted thinning as evidence of photoreceptor nuclear loss (17, 49, 50).
Population-based and cohort studies demonstrated progressive ONL thinning with aging and increasing AMD severity, while structure–function analyses linked ONL thickness to retinal sensitivity, reading performance, and other functional measures (54, 58, 103). These findings support the biological plausibility of ONL thickness as a marker of photoreceptor quantity.
Nevertheless, segmentation variability persisted, particularly regarding treatment of the Henle fiber layer (HFL). Most automated algorithms segment the HFL together with the ONL, thereby increasing measured thickness relative to histological definitions, whereas a smaller number of studies attempted to exclude or model HFL separately using directional or reflectivity-based approaches. Because HFL orientation is most prominent in parafoveal regions, inclusion or exclusion can materially influence measured ONL thickness and contribute to regional variability. Thus, even for nuclear-layer metrics, segmentation boundary selection remains a source of between-study inconsistency (Table 1).
Several investigations examined ONL behavior over drusen, reporting local thinning of the drusen-overlying retina and suggesting early photoreceptor compromise (87, 123). However, in early and intermediate AMD, reductions in EZ reflectivity or focal EZ disruption were often reported before frank ONL thinning, suggesting a potential temporal sequence in which inner segment dysfunction precedes nuclear loss.
3.2.3. Composite outer retinal span metrics
A third category comprised composite outer retinal spans that combined multiple layers within a single anterior–posterior measurement, such as anterior ONL-to-RPE or ELM-to-RPE distances. These metrics were used to estimate overall “outer retinal thickness” or structural integrity, implicitly integrating nuclear and segmental compartments (89).
While composite measures may offer pragmatic advantages, they obscure the specific anatomical compartment driving change. Because nuclear, inner segment, and outer segment components may degenerate at different rates, combining them into a single axial span complicates biological interpretation and limits mechanistic specificity.
Recent work has also focused on atrophy-related constructs, including iRORA, cRORA, junctional-zone metrics, and hypertransmission defects (45, 97). Although hypertransmission is driven primarily by RPE attenuation or loss and frequently co-localizes with EZ and ONL abnormalities, these constructs do not directly quantify axial photoreceptor thickness. Accordingly, while highly relevant to disease staging and progression modeling, they were not considered primary axial photoreceptor integrity measures within the core framework of this review. Across compartments, axial photoreceptor quantification is therefore not a single construct, but a family of boundary-dependent ran whose interpretation depends on anatomical assumptions, segmentation rules, and spatial sampling design.
3.3. Methodological replicability and boundary variability
To contextualize the reliability and validity findings that follow, each study was appraised across five prespecified methodological domains (Table 3). In summary, formal in-study reliability statistics were reported in 18 studies (19%) (Table 2), region-of-interest geometry was specified in 82 (87%), with eccentricity- or topography-stratified analysis in only 29 (31%), and explicit segmentation oversight was documented in 55 (59%) (Supplementary Table S2); phenotype reporting was inconsistent (§3.5). Boundary-specification adequacy is detailed below.
Across 94 included studies, segmentation boundaries for photoreceptor biomarkers were fully and explicitly specified in 41 (44%), partially specified in 32 (34%), and insufficiently described to permit independent replication in 21 (22%) (Table 1). In these latter studies, the anatomical borders underlying thickness or loss metrics were either ambiguously described (e.g., “EZ thickness” without boundary specification) or defined using device-default terminology, without clarification of the anterior and posterior interfaces.
The EZ was the most frequently analyzed structure (n = 62 studies) (Table 6). However, the term “EZ thickness” or “EZ loss” encompasses at least five distinct boundary configurations, including ELM-to-EZ inner border, EZ inner-to-outer border, EZ-to-IZ, EZ-to-RPE, and composite EZ-to-RPE slabs. Reflectivity-based EZ biomarkers demonstrated further heterogeneity, with at least four normalization strategies identified, including IPL-referenced scaling, ELM-referenced ratios (rEZR), internal peak-referenced scaling, and unnormalized intensity metrics. In 28% of reflectivity-based studies, the reference standard for normalization was not specified.
Outer nuclear layer (ONL) thickness was reported in 39 studies and defined using at least four boundary configurations, most commonly OPL-to-ELM, but also including alternative OPL boundary selections and composite outer retinal slabs (Table 6). Anterior OPL border selection was not explicitly specified in approximately one-third of ONL studies. Identical anatomical boundaries were frequently labeled with different terminology, while identical terms were used to describe different boundary constructs, limiting cross-study comparability despite superficial similarity of metrics.
Threshold definitions for attenuation or loss also varied substantially. EZ loss thresholds ranged from complete collapse (0 μm) to partial attenuation defined at ≤ 20 μm, while ELM disruption was variably defined using categorical continuity grading, percentage interruption, or absolute thickness cut-offs. Hypertransmission size thresholds for atrophy varied between CAM-aligned definitions and non-size-based constructs. In 37% of studies employing binary thresholds, the rationale for cut-off selection was not provided.
Region-of-interest (ROI) strategies were similarly heterogeneous. Twenty-nine studies employed ETDRS subfields, 18 used lesion-centric or contour-based ROIs, 21 applied custom macula-wide slabs, 14 used pointwise microperimetry-aligned ROIs, and 12 did not explicitly define ROI geometry. Only 31% of studies explicitly incorporated eccentricity-adjusted or topography-stratified analyses, despite known macular thickness gradients.
Collectively, these findings demonstrate that axial photoreceptor quantification represents a family of boundary-dependent surrogates rather than a single construct. This construct instability has direct implications for AI validation, reproducibility, and interpretation of imaging-derived trial endpoints. The scale of boundary, threshold, and ROI variability provides a quantitative explanation for cross-study heterogeneity and reinforces the central conclusion of this review: reproducibility is high when segmentation conventions are explicitly defined and consistently applied, but methodological comparability is limited when anatomical boundaries are incompletely specified.
3.4. Segmentation methodology and reliability evidence
Of the 94 included studies, 18 (19%) formally reported inter- or intra-grader reliability statistics for photoreceptor-layer metrics. Among studies reporting intraclass correlation coefficients (ICCs) for continuous measures (e.g., ONL thickness, EZ–RPE span), values ranged from 0.87 to 0.97, with the majority exceeding 0.90 under prespecified segmentation protocols and adequate image quality. Agreement was lower for categorical constructs such as partial EZ disruption or transitional atrophic states, particularly in morphologically complex AMD. Reliability evidence supporting trial readiness, including reported vs. inferred reproducibility, is summarized in Table 2.
Because axial photoreceptor metrics depend critically on boundary placement, segmentation methodology represents a central determinant of reliability. Across the included literature, segmentation approaches evolved from manual grading and device-native software with extensive correction to custom research pipelines and fully automated or deep-learning–based algorithms. Earlier studies and anatomically complex cases frequently relied on manual or semi-automated workflows to adjudicate subtle outer retinal bands, whereas later investigations increasingly adopted automated pipelines to enable dense volumetric analysis, longitudinal modeling, and scalability to trial-sized datasets (37, 43, 78, 85).
Where formally reported, inter- and intra-grader agreement for quantitative EZ and ONL thickness measurements was generally high under constrained conditions, specifically when segmentation rules were prespecified, image quality was high, and analyses were restricted to eyes with relatively preserved outer retinal architecture. However, reproducibility declined in the presence of thin layers, gradual transition zones, or complex AMD-related pathology, including drusen, nascent atrophy, intraretinal or subretinal fluid, and subretinal hyperreflective material (17, 75, 97). In these settings, ambiguity in defining anterior and posterior borders, particularly at the EZ–RPE interface or within attenuated ONL regions, was a major contributor to intergrader variability.
Cross-reader and cross-disease validation studies demonstrated good agreement for EZ- and ONL-based metrics in non-atrophic or structurally simpler disease contexts (32). However, this performance did not consistently generalize to AMD cohorts characterized by progressive thinning, band merging, or evolving atrophy. Comparisons using high-resolution OCT further underscored that axial resolution, scan averaging, and preprocessing strategies influence delineation of outer retinal bands and atrophic lesion boundaries, with direct implications for both reliability and sensitivity to change (55, 71).
Automated segmentation pipelines were increasingly applied not only for structural quantification but also for prognostic modeling and treatment-response analyses, including prediction of progression to late AMD and evaluation of therapeutic effects in phase 3 datasets (35, 72, 86, 89, 96). While these approaches enhance scalability and consistency, multiple studies emphasized the continued need for manual review or adjudication in AMD to mitigate segmentation failure modes arising from thin, ambiguous, or out-of-distribution morphology (75, 97). Segmentation pipelines, oversight, and adjudication workflows are detailed in Supplementary Table S2.
Taken together, reliability evidence suggests that axial photoreceptor thickness metrics are reproducible when anatomical boundaries are clearly defined and outer retinal architecture is preserved. However, in advanced or morphologically complex AMD, precisely where such biomarkers are most clinically relevant, segmentation ambiguity becomes a principal source of variability. Device-specific acquisition parameters and processing pipelines further modulate performance and are summarized in Supplementary Table S3.
3.5. Phenotypic context and reporting completeness
Interpretation of axial photoreceptor metrics is further influenced by phenotypic context. Across studies, reporting of biologically relevant modifiers was inconsistent, limiting phenotype-resolved interpretation of thickness-derived biomarkers.
Drusen presence was commonly documented, but detailed characterization of drusen subtype, burden, and internal composition was variably reported. Several investigations demonstrated associations between drusen-associated morphology and local photoreceptor alteration, and highlighted the feasibility of AI-based drusen segmentation to support quantitative phenotyping (74, 85, 87, 123). Because drusen can distort overlying outer retinal architecture, failure to account for drusen morphology may confound the interpretation of axial thickness metrics.
Subretinal drusenoid deposits (SDD), also known as reticular pseudodrusen (RPD), were frequently mentioned but inconsistently quantified. SDD are associated with characteristic topographic patterns of degeneration and rod dysfunction, and have been shown to exhibit distinct spatial distributions on en face OCT compared with infrared imaging (63, 91, 124). Importantly, SDD and interdigitation zone alterations may alter apparent layer boundaries and reflectivity profiles. In studies employing EZ-to-RPE or other composite outer retinal spans, these features can introduce additional variability in thickness estimates even in the absence of overt photoreceptor cell-body loss.
Reporting of macular neovascularization (MNV) subtype was also uneven. While some neovascular AMD studies stratified outcomes by lesion type or specific morphological features, others did not clearly distinguish between subtypes (118, 120). Because fluid, subretinal hyperreflective material, and bacillary layer changes can distort outer retinal bands, inconsistent phenotype reporting limits cross-study synthesis of photoreceptor biomarkers in neovascular contexts.
Overall, incomplete phenotypic characterization complicates the interpretation of axial thickness metrics, particularly where segmentation boundaries are already sensitive to morphological distortion. Standardized reporting of drusen phenotype, SDD presence, and neovascular subtype would enhance comparability and biological interpretability of photoreceptor integrity measures. CAM adoption and atrophy-definition frameworks are summarized in Supplementary Table S4.
3.6. Structure–function relationships
Structure–function analysis formed a central component of the reviewed literature. Functional endpoints included mesopic and scotopic microperimetry, best-corrected visual acuity (BCVA), low-luminance acuity, electrophysiological measures, and performance-based outcomes such as reading speed (54, 58, 79, 91). These associations are summarized by AMD stage, biomarker type, and functional endpoint in Table 7, which reports the direction and strength of reported relationships and representative studies; values are reported ranges and representative findings rather than pooled estimates.
TABLE 7.
Structure–function relationships by AMD stage, biomarker type, and functional endpoint.
| AMD stage | Biomarker type | Functional endpoint | Reported association (direction/strength) | Representative studies (ref. #) |
|---|---|---|---|---|
| Early/intermediate AMD | EZ (reflectivity, thickness, focal disruption) | Mesopic and scotopic microperimetry (pointwise sensitivity) | Moderate–strong; stepwise reduction in relative EZ reflectivity with severity; DL-derived EZ metrics associated with local sensitivity loss even without overt atrophy | (6, 60, 89, 91) |
| Early/intermediate AMD | ONL thickness | Microperimetry, contrast sensitivity, reading performance | Thinner ONL → reduced sensitivity; evidence of non-linear/threshold relationship (preserved function until critical thinning) | (34, 38, 91, 108) |
| Early/intermediate AMD | Composite/partial outer-retinal thickness (incl. RPD) | Scotopic and mesopic fundus-controlled perimetry; deep sensitivity | Correlated with deep/scotopic sensitivity loss; stronger than high-contrast acuity for parafoveal change | (33, 86, 87, 103) |
| Early/intermediate AMD | EZ/ONL | BCVA | Generally weak; BCVA insensitive to parafoveal/extrafoveal loss in early disease | (68) |
| Geographic atrophy | EZ loss/disruption | Pointwise microperimetry | Strong local coupling; sensitivity decrements frequently > 10 dB at EZ-disrupted loci; residual function within lesions and pronounced loss at margins | (7, 34, 73, 74, 75) |
| Geographic atrophy | ELM + EZ + ONL (composite) | BCVA; cone- and rod-mediated function | ELM disruption with EZ/ONL loss → worse VA; combined photoreceptor + RPE features best explain functional variance | (15, 74) |
| Geographic atrophy | EZ–RPE/outer-retinal thickness | Deep visual sensitivity | OCT-defined atrophic change associated with deep visual-sensitivity losses (multicentre) | (86, 122) |
| Neovascular AMD | EZ and ELM integrity | BCVA; retinal sensitivity; treatment response | EZ/ELM integrity prognostic for visual outcome; AI morphology features predict function and activity | (100, 104, 117, 120, 121) |
| Across stages (synthesized) | EZ/ONL (overall) | Microperimetry sensitivity | r ≈ 0.50–0.80 (stronger in advanced disease) | Results §3.6; Abstract |
| Across stages (synthesized) | EZ/ONL (overall) | BCVA | r ≈ 0.40–0.70 (context-dependent) | Results §3.6; Abstract |
Values are reported ranges and representative findings synthesized across methodologically heterogeneous studies; they are not pooled effect sizes. Correlation strength is influenced by microperimetry grid design, test density, spatial-alignment strategy, boundary definition, and disease stage. BCVA, best-corrected visual acuity; DL, deep learning; EZ, ellipsoid zone; ELM, external limiting membrane; ONL, outer nuclear layer; RPD, reticular pseudodrusen; RPE, retinal pigment epithelium.
Microperimetry was particularly informative because it enabled topographic alignment between OCT-derived photoreceptor metrics and pointwise retinal sensitivity (33, 54, 91). In intermediate AMD, deep-learning–derived structural metrics demonstrated associations with local sensitivity loss even in the absence of overt atrophy (33, 84). These findings support the biological plausibility of axial thickness and reflectivity metrics as markers of functional impairment.
However, the strength and spatial specificity of structure–function correlations varied with microperimetry grid design, test density, and alignment strategy. Lesion-targeted or adaptive microperimetry grids highlighted limitations of standard sampling approaches for focal pathology and underscored the importance of spatial congruence when relating structural biomarkers to functional outcomes (56). Thus, variability in topographic sampling, already identified as a source of structural heterogeneity, extends directly to functional correlation analyses.
In GA, spatially resolved studies demonstrated residual function within atrophic areas and pronounced sensitivity loss at lesion margins (8, 79, 80), reinforcing the clinical relevance of high-resolution OCT mapping. These findings also suggest that photoreceptor degeneration may extend beyond clinically defined lesion borders, depending on the structural definition applied.
BCVA was widely reported but generally less sensitive to parafoveal or extrafoveal photoreceptor loss, particularly in earlier disease stages (10). Nonetheless, associations between outer retinal integrity and BCVA were observed in specific contexts, including foveal-sparing GA and treatment-response analyses (39). Low-luminance and deep-sensitivity measures more consistently captured functional deficits not reflected in high-contrast acuity and showed stronger associations with parafoveal or eccentric structural change (51, 53, 125).
Taken together, structure–function evidence supports the biological validity of axial photoreceptor metrics. However, the magnitude and localization of these associations depend on precise spatial alignment, consistent boundary definition, and phenotypic context. Variability in these methodological parameters likely contributes to between-study differences in reported correlation strength.
3.7. Agreement between OCT- and FAF-based atrophy assessment
A subset of studies directly compared OCT-based atrophy constructs with FAF-derived GA measures. Across cohorts, strong correlations were observed between OCT- and FAF-based GA area, with high sensitivity and specificity for lesion detection (44, 47). Large trial-linked analyses demonstrated close correspondence between automated OCT-derived GA measurements and conventional FAF endpoints, supporting OCT as a feasible modality for GA monitoring in clinical trials (44, 47, 72).
However, the magnitude of agreement depended on the operational definitions used, particularly the thresholds for defining atrophy onset and lesion margins across modalities. Differences in whether atrophy was defined by complete RPE and outer retinal loss (e.g., cRORA) or by FAF hypoautofluorescence influenced both lesion area estimates and margin delineation (45, 78, 79).
Importantly, OCT–FAF discordance was biologically informative rather than contradictory. Structural OCT frequently identified outer retinal thinning, EZ loss, and subsidence preceding the development of definitive hypoautofluorescence, suggesting a structural lead time, particularly at lesion margins and in nascent atrophy (45, 78, 79). Conversely, FAF may detect metabolic RPE dysfunction that precedes complete photoreceptor loss or does not meet strict OCT-based atrophy criteria (45, 78).
A recent phase 3 trial–linked analysis directly compared automated SD-OCT–derived geographic atrophy measurements with conventional FAF-based endpoints and demonstrated high overall agreement in total lesion area (72). However, systematic differences emerged at lesion margins, where modality-specific definitions of atrophy and differing sensitivity to early structural change influenced boundary delineation. OCT-based definitions, grounded in axial outer retinal and RPE structural loss, frequently identified subtle subsidence or photoreceptor attenuation not yet meeting FAF hypoautofluorescence criteria. Conversely, FAF sometimes detected metabolic RPE dysfunction without complete structural collapse on OCT.
These findings suggest that apparent discrepancies between OCT and FAF are not simply measurement error, however reflect differences in the biological compartment being captured—axial outer retinal structural integrity on OCT versus RPE metabolic status on FAF. Together, these data support a complementary, multimodal framework for atrophy assessment, in which OCT provides direct structural quantification of nuclear and inner segment compartments, while FAF reflects RPE functional integrity. Harmonization of atrophy definitions across modalities, including explicit specification of structural thresholds and boundary criteria, will be essential to ensure consistent endpoint interpretation in both observational studies and interventional trials.
3.8. Imaging protocols and adoption of standardization frameworks
Imaging acquisition protocols varied substantially across studies in terms of scan density, field size, averaging strategies, motion correction, and reporting transparency. Earlier investigations frequently relied on lower-density raster scans and device-native acquisition settings, whereas more recent studies increasingly adopted high-density volumetric protocols to enable en face mapping, three-dimensional reconstruction, and deep-learning–based segmentation workflows. Such methodological shifts have direct implications for axial layer delineation, particularly in thin or transitional zones where sampling density and signal averaging influence boundary detection. Device models, acquisition protocols, and QC thresholds across studies are summarized in Supplementary Table S3.
Adoption of the Classification of Atrophy Meeting (CAM) definitions for atrophy was evident in an increasing proportion of the literature and was associated with improved inter-reader agreement and longitudinal consistency, particularly for lesion definition and progression endpoints (24, 97). The CAM framework provides explicit structural criteria for atrophy classification, thereby reducing interpretive variability at lesion borders.
However, for photoreceptor-specific biomarkers, no equivalent consensus framework exists. Many studies continued to employ custom segmentation rules, device-specific algorithms, or hypothesis-driven composite measures of outer retinal thickness. While such innovation has advanced quantitative analysis and prognostic modeling, it has also introduced heterogeneity in layer definitions, thresholding rules, and spatial sampling strategies. This tension between methodological innovation and the need for harmonization is particularly salient for axial photoreceptor metrics, where small variations in acquisition parameters or segmentation rules can materially influence measured thickness.
Collectively, the literature demonstrates increasing standardization of atrophy endpoints, but continued variability in photoreceptor-layer quantification. Establishing clearer reporting standards, including explicit specification of acquisition parameters, segmentation boundaries, and topographic sampling frameworks, will be essential for cross-study comparability and for the translation of axial photoreceptor biomarkers into robust clinical trial endpoints. These gaps motivate a minimum reporting framework (Table 8).
TABLE 8.
Minimum reporting framework for OCT-derived photoreceptor biomarkers in AMD.
| Domain | Required reporting elements | Rationale |
|---|---|---|
| 1. Anatomical definition and segmentation boundaries | Explicit anterior and posterior boundaries for each biomarker (e.g., EZ–RPE, OPL–ELM) Inclusion/exclusion of adjacent layers (e.g., Henle fiber layer) Criteria for attenuation vs. complete loss Handling of transitional/ambiguous bands |
Boundary choice materially alters quantitative outputs; explicit definition prevents construct drift across studies. |
| 2. Imaging platform and acquisition parameters | Device manufacturer and model Software version and segmentation algorithm (native vs. custom vs. DL) Scan protocol (field size, raster density, averaging, eye tracking) Axial/lateral resolution (if relevant) Quality control thresholds and exclusion criteria |
Device architecture and acquisition parameters influence band visibility, thickness measurements, and reflectivity metrics. |
| 3. Analytic domain and measurement strategy | Measurement domain (B-scan, en face, slab, volumetric) Units (thickness, area, volume, reflectivity index) Preprocessing steps (flattening reference, interpolation, motion correction) Handling of ungradable regions or missing data |
Analytic strategy determines spatial sampling and sensitivity to focal vs. diffuse degeneration. |
| 4. Reflectivity and intensity normalization | Reference structure used for normalization (e.g., RPE, vitreous, internal band) Thresholding logic for defect definition Signal strength adjustments Statement on inter-device comparability |
Reflectivity-based biomarkers are device- and signal-dependent; transparent normalization reduces measurement artefact. |
| 5. Region of interest (ROI) and topographic reference | ROI definition (ETDRS grid, central 1 mm, lesion-centric mask, whole macula) Inclusion/exclusion of lesion margins Spatial alignment method (fovea-centered, MP-aligned, etc.) Biological justification for ROI choice |
Spatial sampling strongly influences structure–function correlations and progression rates. |
| 6. Phenotypic Stratification | Drusen subtype/burden Presence of SDD MNV subtype (if applicable) Atrophy classification framework (e.g., CAM iRORA/cRORA) |
Photoreceptor metrics behave differently across phenotypes; stratification improves interpretability and external validity. |
| 7. Reliability and validation | Type of reliability statistic (ICC, κ, Dice, CoR) Sample size used for reliability testing Inter- and/or intra-grader assessment Cross-device validation (if applicable) Adjudication procedures |
High reliability is conditional on clearly defined boundaries and consistent analytic rules. |
| 8. Longitudinal and Progression Modeling (if applicable) | Definition of progression event Inter-scan interval Handling of segmentation drift Sensitivity analyses for boundary ambiguity |
Longitudinal metrics are particularly vulnerable to boundary instability and algorithm drift. |
AMD, age-related macular degeneration; CAM, Classification of Atrophy Meetings; CoR, coefficient of repeatability; DL, deep learning; ETDRS, Early Treatment Diabetic Retinopathy Study; EZ, ellipsoid zone; ICC, intraclass correlation coefficient; iRORA, incomplete retinal pigment epithelium and outer retinal atrophy; cRORA, complete retinal pigment epithelium and outer retinal atrophy; MNV, macular neovascularisation; OCT, optical coherence tomography; OPL, outer plexiform layer; RPE, retinal pigment epithelium; ROI, region of interest; SDD, subretinal drusenoid deposits; κ, kappa statistic. To facilitate harmonization and regulatory translation, we propose a minimum reporting framework for OCT-derived photoreceptor biomarkers structured to address the principal sources of construct variability identified in this review.
4. Discussion
This scoping review demonstrates that OCT-derived photoreceptor-layer biomarkers in AMD are not a single construct, but a family of anatomically distinct, boundary-dependent axial surrogates, most commonly derived from the ellipsoid zone and outer nuclear layer. Across disease stages, these measures demonstrate analytical robustness and biological relevance when segmentation conventions are clearly specified, spatial sampling is standardized, and quality control procedures are applied. However, their interpretation depends critically on how anatomical borders are defined, how spatial sampling is performed, and how transitional states are operationalized. Recognizing these dependencies is essential to distinguishing biological signal from methodological artifact and to advancing photoreceptor metrics toward regulatory-grade application.
4.1. Analytical validity and reliability
Across studies reporting formal reproducibility outcomes, inter- and intra-rater reliability for quantitative photoreceptor biomarkers was consistently high, particularly for continuous measures such as ONL thickness, EZ–RPE thickness, and OCT-derived GA area. Among the subset of studies that formally reported inter-grader reliability statistics, intraclass correlation coefficients (ICCs) for continuous thickness measures consistently exceeded 0.90, supporting their suitability for group-level comparisons and longitudinal assessment. However, the majority of included studies relied on inferred reliability based on previously validated segmentation pipelines or established reading-center protocols, without reporting in-study reproducibility metrics (17, 32, 75). In contrast, agreement was lower for categorical or transitional constructs, including partial EZ disruption and early incomplete RPE and outer retinal atrophy (iRORA), which explicitly incorporates hypertransmission defects and subtle outer retinal changes, a pattern consistently observed across intergrader studies (38, 97), particularly at lesion margins where hypertransmission, EZ attenuation, and ONL thinning may not yet co-localize. This reduced agreement likely reflects the intrinsic subtlety and boundary ambiguity in early structural transition of OCT-based assessment.
The literature also documents a clear methodological evolution from manual and semi-automated segmentation to fully automated, deep-learning–based pipelines. Quantitative validation studies demonstrate that contemporary automated approaches achieve agreement comparable to, and in some cases exceeding, expert manual grading for EZ and ONL boundaries (32, 68). High Dice similarity coefficients and excellent test–retest reliability have been reported across diverse retinal diseases, including AMD, supporting scalability to large observational cohorts and multicenter trials. However, generalizability remains dependent on the composition of the training data, imaging platform heterogeneity, and critically, the alignment and stability of the ground-truth anatomical definitions used for validation. Several studies have noted performance degradation when algorithms were applied across devices or populations not represented in the training set, reinforcing the importance of external validation and human-in-the-loop quality control (75, 96).
From a practical grading and acquisition perspective, operability constraints represent a major determinant of observed variability, particularly for reflectivity- and continuity-based EZ metrics. In routine clinical and trial imaging, EZ intensity and reflectivity are influenced by optical media clarity, pupil size, focus, signal strength, and scan quality, such that apparent “dimming” of the EZ may reflect acquisition factors rather than biological change. Motion artifact, poor fixation, decentration, and shadowing from overlying pathology can further distort the appearance and continuity of the outer retinal band. In neovascular AMD, intraretinal or subretinal fluid and subretinal hyperreflective material may render the EZ intermittently ungradable or spuriously variable across visits. Automated pipelines introduce additional dependencies on preprocessing choices, including flattening reference, slab definition, reflectivity normalization, and thresholding, which can materially alter measured EZ extent or thickness and limit portability across devices and sites. These operability considerations help explain why high reproducibility is most consistently observed under constrained conditions and underscore the continued need for prespecified rules, quality control, and expert adjudication in both manual and automated analyses.
Collectively, these findings indicate that photoreceptor biomarkers can satisfy key criteria for analytical validation when segmentation rules are explicitly defined, consistently applied, and supported by appropriate quality control and phenotype-aware interpretation. Automated and AI-enabled approaches appear well-suited to augment expert oversight in regulatory-grade applications, but current evidence does not support their use as complete replacements for human adjudication in pivotal trials.
4.2. Biological plausibility and structure–function coupling
A central and unifying finding of this review is the consistency and biological plausibility of structure–function relationships linking photoreceptor biomarkers to visual outcomes. EZ integrity, operationalized across studies as loss or attenuation of the EZ band, reductions in EZ reflectivity, or decreases in EZ thickness, area, or volume, emerged as the most informative single correlate, demonstrating moderate-to-strong associations with both global functional measures and spatially resolved outcomes such as pointwise retinal sensitivity (78, 124). Spatially resolved analyses consistently showed large decrements in retinal sensitivity, often exceeding 10 dB, at loci with EZ disruption, supporting a direct local coupling between photoreceptor structure and function (54, 80).
ONL thickness provided complementary information, particularly as a marker of photoreceptor cell-body loss. Numerous cohort and population-based studies demonstrated progressive ONL thinning with increasing AMD severity and aging (17, 50). Structure–function analyses further linked ONL thinning, defined either in absolute terms or relative to age-matched normative reference data, to reduced retinal sensitivity, contrast sensitivity, and reading performance (54, 58). Importantly, spatially resolved structure–function analyses suggested potential non-linear relationships between ONL thickness and functional sensitivity, with relative preservation of function at higher thickness ranges and steeper decline once thinning progressed beyond a critical threshold (33, 54, 91, 103).
ELM status and composite outer retinal metrics refined structure–function associations, particularly in advanced disease and perilesional regions. In GA, disruption of the ELM in conjunction with EZ and ONL loss was associated with worse visual acuity and more pronounced functional impairment, supporting its role as a marker of advanced photoreceptor degeneration (39, 79). Deep-learning–based analyses further demonstrated that combined photoreceptor and RPE features best explained variability in cone- and rod-mediated function, reinforcing a layered and stage-dependent model of structure–function coupling (33, 79).
Together, these data support a conceptual framework in which EZ, ONL, and ELM metrics provide complementary rather than interchangeable information, capturing different aspects of photoreceptor integrity across the AMD spectrum.
4.3. Comparison with established endpoints and multimodal imaging
The high concordance between OCT- and fundus autofluorescence (FAF)-based assessment of GA provides quantitative support for OCT as a valid alternative or complement to FAF in clinical trials. Multiple studies reported strong correlations between OCT-derived GA area and FAF-defined lesions, with high sensitivity and specificity for lesion detection (47, 72). Trial-linked analyses from the OAKS and DERBY studies further demonstrated close correspondence between automated OCT-derived GA measurements and conventional FAF endpoints, supporting the feasibility of OCT-based monitoring in phase 3 trials (72), particularly when consistent operational definitions and lesion-boundary thresholds were applied across modalities.
Importantly, OCT–FAF discordance was consistently shown to be biologically informative rather than contradictory. Longitudinal studies demonstrated that OCT can identify photoreceptor loss, outer retinal subsidence, and early cRORA-like change at lesion margins and in nascent atrophy before the development of definitive hypoautofluorescence, suggesting a structural lead time (45, 78). Conversely, FAF may detect metabolic RPE dysfunction that precedes complete photoreceptor loss or does not meet strict OCT-based atrophy criteria (115). The relative timing and magnitude of these signals depend on the specific atrophy definitions and thresholds applied, underscoring that OCT and FAF probe complementary aspects of the degenerative process. These complementary strengths argue strongly for multimodal imaging strategies in both trials and high-resolution observational studies.
4.4. Implications for clinical trials and regulatory science
From a regulatory science perspective, candidate structural endpoints must demonstrate analytical validity, biological relevance, sensitivity to change over trial-relevant intervals, and interpretability in relation to patient benefit (23). Across these domains, EZ- and ONL-based OCT biomarkers address many criteria for early-phase and enrichment endpoints in AMD; however, regulatory interpretation remains dependent on harmonized construct definitions and transparent validation frameworks, particularly when definitions are prespecified, segmentation boundaries are harmonized, and phenotypic context is incorporated into analytical frameworks (10, 11), and may also serve as eligibility or enrichment criteria to define at-risk populations or exclude eyes with advanced, non-modifiable photoreceptor loss, provided that segmentation conventions, phenotype context, and analytic definitions are prespecified and consistently applied.
Longitudinal evidence indicates that photoreceptor biomarkers not only reflect contemporaneous function but also predict subsequent visual decline. Several studies demonstrated that baseline EZ or ONL integrity and rates of photoreceptor loss were associated with future development of GA, foveal involvement, or visual acuity decline (42, 52, 78). These associations were most robust when biomarkers were derived from anatomically relevant regions and interpreted in the context of disease stage and phenotype, aligning photoreceptor metrics with conceptual frameworks for candidate surrogate endpoints, biomarkers reasonably likely to predict clinical benefit, pending confirmation in interventional trials.
Photoreceptor biomarkers also offer opportunities for risk enrichment and patient stratification, enabling identification of eyes at higher risk of progression based on baseline structural vulnerability. In established GA, preservation of perilesional photoreceptors may provide treatment-responsive outcomes complementary to GA area alone, particularly for therapies targeting early disease mechanisms (77, 96), and may enhance sensitivity to detect treatment effects over shorter trial durations.
4.5. CLEAR framework: standardization priorities and future directions
The heterogeneity observed across studies underscores that analytical robustness is contingent upon boundary stability and harmonized operational definitions. Despite a strong overall signal, substantial heterogeneity in biomarker definitions, thresholds, and regions of interest remains a major barrier to adoption. EZ metrics alone encompassed dozens of operational definitions across the literature, while ONL boundaries and spatial sampling strategies varied widely. Phenotypic stratification by drusen subtype, subretinal drusenoid deposit status, and macular neovascularization subtype was inconsistently reported, limiting biologically meaningful synthesis (27, 63), and constraining the use of photoreceptor biomarkers as reproducible eligibility or enrichment criteria across trials.
The success of the Classification of Atrophy Meeting (CAM) framework provides a clear model for extending consensus to photoreceptor biomarkers (24, 126, 127). The CLEAR initiative was conceived as a complementary effort focused on harmonizing photoreceptor-layer constructs, AI validation strategies, segmentation conventions, and reporting standards for OCT-derived biomarkers in AMD. Priorities include agreement on segmentation boundaries, preferred regions of interest, measurement units, thresholds for partial versus complete disruption, validation datasets, and minimum reporting requirements for AI-enabled biomarker quantification, with explicit consideration of how these definitions will be applied for both trial eligibility, enrichment, and longitudinal endpoints, aligned with INOCT nomenclature (16). Routine ETDRS-based reporting, mandatory phenotypic context, and standardized reliability reporting would substantially enhance cross-study synthesis, facilitate regulatory acceptance, and accelerate translation into clinical trials. Exploratory evidence implicating Müller-cell–associated structures, including ELM-related metrics and reflectivity-based surrogates, is summarized in Supplementary Table S4 and should be interpreted as hypothesis-generating rather than endpoint-ready.
4.6. Emerging photoreceptor biomarkers
Beyond EZ and ONL metrics, several emerging biomarkers may refine photoreceptor characterization. Interdigitation zone (IZ) integrity, reflecting the apposition of outer segments to RPE apical processes, is increasingly resolvable with high-resolution, high-density OCT and may be among the earliest bands to attenuate; however, its visibility is acquisition-dependent, and inter-reader concordance remains to be established (55, 59, 81). Photoreceptor reflectivity profiles, including directional (Stiles–Crawford-related) EZ reflectivity and relative EZ reflectivity (rEZR), provide intensity-based surrogates of inner-segment health that show a stepwise decline with disease severity and associations with function, but are sensitive to acquisition parameters and normalization strategies (60, 70, 90, 104, 105). Outer retinal hyperreflective foci (HRF), implicated in RPE migration and intraretinal cellular changes, carry prognostic value for progression and may modify the interpretation of overlying photoreceptor metrics (92). Finally, adaptive optics and high-magnification imaging enable in vivo quantification of cone density and mosaic regularity, providing cellular-scale validation of axial OCT surrogates, particularly in eyes with subretinal drusenoid deposits (27, 106). These biomarkers are currently heterogeneous in definition and limited in evidence of reproducibility, and we therefore regard them as hypothesis-generating priorities for the CLEAR harmonization agenda rather than trial-ready endpoints.
4.7. CLEAR framework implications
A central finding of this review is that many OCT-derived photoreceptor biomarkers currently function as boundary-dependent analytical constructs rather than universally standardized anatomical entities. This has important implications for AI validation and regulatory science because algorithm performance metrics are inherently dependent on the underlying construct definition used as the reference standard. Apparent differences in algorithm performance may therefore reflect instability or inconsistency in the endpoint definition itself rather than true differences in segmentation capability.
The CLEAR initiative (Consensus Layer Evaluation for AI Algorithm Reporting) was developed to address these challenges through harmonization of segmentation conventions, biomarker terminology, reporting standards, and validation approaches for AI-enabled OCT biomarkers in AMD. The present manuscript serves as CLEAR Report 1 by defining the conceptual and methodological landscape underpinning photoreceptor biomarker interpretation and reproducibility.
4.8. Strengths and limitations
This review integrates operational definitions, reliability evidence, structure–function associations, and cross-modal agreement, providing a comprehensive assessment of OCT-derived photoreceptor biomarkers not previously available. Strengths include a broad, systematic search, adherence to PRISMA-ScR guidance (128), dual data extraction, and quantitative synthesis where feasible. Limitations primarily reflect the underlying literature, including inconsistent reporting, modest sample sizes in some cohorts, and limited phenotype-stratified data. As a scoping review, a formal risk-of-bias assessment was not performed because the primary objectives were to map the existing literature, clarify key concepts and operational definitions, identify knowledge gaps, and determine whether a more focused systematic review with certainty grading is currently feasible; no validated risk of bias instrument exists for this construct mapping aim. To ensure that our conclusions regarding reliability, biological validity, and trial readiness were not drawn uncritically, we instead conducted a structured appraisal of methodological rigor across five prespecified domains (§2.7), which provides a transparent, study-level signal of methodological quality in place of a formal risk-of-bias score.
5. Conclusion
In summary, OCT-derived photoreceptor biomarkers, particularly EZ and ONL metrics, can be reproducible, biologically meaningful, and closely linked to visual function when segmentation boundaries and analytic conventions are clearly specified and consistently applied. When defined and applied in a fit-for-purpose manner, these biomarkers can support multiple trial functions, including eligibility and enrichment strategies, risk stratification, and sensitive outcome assessment beyond conventional visual acuity.
These measures demonstrate the evidentiary foundation necessary for candidate trial endpoints, but their translation to regulatory-grade application requires consensus on segmentation standards, phenotype reporting, and cross-platform validation; steps that the heterogeneity documented in this review makes both necessary and achievable. Continued consensus-building, modeled on the CAM framework and explicitly extending to photoreceptor-specific constructs, will be critical to harmonizing definitions, reducing operability-related variability, and realizing the full translational and regulatory potential of photoreceptor biomarkers in AMD. CLEAR Report 1 provides the conceptual and evidentiary foundation for future efforts focused on AI validation, harmonized reporting standards, and regulatory-grade photoreceptor imaging endpoints.
Funding Statement
The author(s) declared that financial support was not received for this work and/or its publication.
Footnotes
Edited by: Georgios D. Panos, Aristotle University of Thessaloniki, Greece
Reviewed by: Lili Takács, University of Debrecen, Hungary
Lukas Goerdt, University of Bonn, Germany
Author contributions
KS: Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Project administration, Resources, Validation, Visualization, Writing – original draft, Writing – review & editing. AG: Data curation, Investigation, Methodology, Validation, Writing – review & editing. AI: Data curation, Investigation, Methodology, Resources, Writing – review & editing. AL: Data curation, Investigation, Methodology, Resources, Writing – review & editing. OT: Methodology, Supervision, Writing – review & editing. LF: Formal analysis, Methodology, Supervision, Validation, Writing – review & editing. SS: Formal analysis, Methodology, Project administration, Supervision, Validation, Writing – review & editing. DF: Conceptualization, Formal analysis, Methodology, Project administration, Resources, Supervision, Validation, Visualization, Writing – review & editing.
Conflict of interest
LF was employed by the Medignition Inc. Research Consultants Zurich.
The remaining author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
Generative AI statement
The author(s) declared that Generative AI was not used in the creation of this manuscript.
Any alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.
Publisher’s note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.
Supplementary material
The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2026.1887548/full#supplementary-material
References
- 1.Bennion AE, Shaw RL, Gibson JM. What do we know about the experience of age related macular degeneration? A systematic review and meta-synthesis of qualitative research. Soc Sci Med. (2012) 75:976–85. 10.1016/j.socscimed.2012.04.023 [DOI] [PubMed] [Google Scholar]
- 2.Jonas JB, Cheung CMG, Panda-Jonas S. Updates on the epidemiology of age-related macular degeneration. Asia Pac J Ophthalmol (Phila). (2017) 6:493–7. 10.22608/APO.2017251 [DOI] [PubMed] [Google Scholar]
- 3.Wong WL, Su X, Li X, Cheung CM, Klein R, Cheng CY, et al. Global prevalence of age-related macular degeneration and disease burden projection for 2020 and 2040: a systematic review and meta-analysis. Lancet Glob Health. (2014) 2:e106–16. 10.1016/S2214-109X(13)70145-1 [DOI] [PubMed] [Google Scholar]
- 4.Khanani AM, Patel SS, Staurenghi G, Tadayoni R, Danzig CJ, Eichenbaum DA, et al. Efficacy and safety of avacincaptad pegol in patients with geographic atrophy (GATHER2): 12-month results from a randomised, double-masked, phase 3 trial. Lancet. (2023) 402:1449–58. 10.1016/S0140-6736(23)01583-0 [DOI] [PubMed] [Google Scholar]
- 5.Liao DS, Grossi FV, El Mehdi D, Gerber MR, Brown DM, Heier JS, et al. Complement C3 inhibitor pegcetacoplan for geographic atrophy secondary to age-related macular degeneration: a randomized phase 2 trial. Ophthalmology. (2020) 127:186–95. 10.1016/j.ophtha.2019.07.011 [DOI] [PubMed] [Google Scholar]
- 6.Curcio C, Medeiros N, Millican C. Photoreceptor loss in age-related macular degeneration. Invest Ophthalmol Visual Sci. (1996) 37:1236–49. [PubMed] [Google Scholar]
- 7.Curcio CA, Zanzottera EC, Ach T, Balaratnasingam C, Freund KB. Activated retinal pigment epithelium, an optical coherence tomography biomarker for progression in age-related macular degeneration. Invest Ophthalmol Vis Sci. (2017) 58:BIO211–26. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Pfau M, Lindner M, Goerdt L, Thiele S, Nadal J, Schmid M, et al. Prognostic value of shape-descriptive factors for the progression of geographic atrophy secondary to age-related macular degeneration. Retina. (2019) 39:1527–40. 10.1097/IAE.0000000000002206 [DOI] [PubMed] [Google Scholar]
- 9.Wu Z, Luu CD, Ayton LN, Goh JK, Lucci LM, Hubbard WC, et al. Optical coherence tomography-defined changes preceding the development of drusen-associated atrophy in age-related macular degeneration. Ophthalmology. (2014) 121:2415–22. 10.1016/j.ophtha.2014.06.034 [DOI] [PubMed] [Google Scholar]
- 10.Owsley C, McGwin G, Clark ME, Jackson GR, Callahan MA, Kline LB, et al. Delayed rod-mediated dark adaptation is a functional biomarker for incident early age-related macular degeneration. Ophthalmology. (2016) 123:344–51. 10.1016/j.ophtha.2015.09.041 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.Sunness JS, Rubin GS, Applegate CA, Bressler NM, Marsh MJ, Hawkins BS, et al. Visual function abnormalities and prognosis in eyes with age-related geographic atrophy of the macula and good visual acuity. Ophthalmology. (1997) 104:1677–91. 10.1016/s0161-6420(97)30079-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Meleth AD, Mettu P, Agrón E, Chew EY, Sadda SR, Ferris FL, et al. Changes in retinal sensitivity in geographic atrophy progression as measured by microperimetry. Invest Ophthalmol Vis Sci. (2011) 52:1119–26. 10.1167/iovs.10-6075 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Midena E, Vujosevic S, Convento E, Manfre’ A, Cavarzeran F, Pilotto E. Microperimetry and fundus autofluorescence in patients with early age-related macular degeneration. Br J Ophthalmol. (2007) 91:1499–503. 10.1136/bjo.2007.119685 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Drexler W, Fujimoto JG. State-of-the-art retinal optical coherence tomography. Prog Retin Eye Res. (2008) 27:45–88. 10.1016/j.preteyeres.2007.07.005 [DOI] [PubMed] [Google Scholar]
- 15.Spaide RF, Curcio CA. Anatomical correlates to the bands seen in the outer retina by optical coherence tomography: literature review and model. Retina. (2011) 31:1609–19. 10.1097/IAE.0b013e3182247535 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Staurenghi G, Sadda S, Chakravarthy U, Spaide RF. Proposed lexicon for anatomic landmarks in normal posterior segment spectral-domain optical coherence tomography: the INOCT consensus. Ophthalmology. (2014) 121:1572–8. 10.1016/j.ophtha.2014.02.023 [DOI] [PubMed] [Google Scholar]
- 17.Brandl C, Brücklmayer C, Günther F, Zimmermann ME, Küchenhoff H, Helbig H, et al. Retinal layer thicknesses in early age-related macular degeneration: results from the German AugUR study. Invest Ophthalmol Vis Sci. (2019) 60:1581–94. 10.1167/iovs.18-25332 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Griffin W, Koronyo Y, Barron E, et al. Retinal vascular and neuronal pathology in early Alzheimer’s disease. Acta Neuropathol. (2021) 141:467–92. 10.3389/fnins.2021.731614 33515276 [DOI] [Google Scholar]
- 19.Bogunovic H, Venhuizen F, Klimscha S, Apostolopoulos S, Bab-Hadiashar A, Bagci U, et al. RETOUCH: the retinal OCT fluid detection and segmentation benchmark and challenge. IEEE Trans Med Imaging. (2019) 38:1858–74. 10.1109/TMI.2019.2901398 [DOI] [PubMed] [Google Scholar]
- 20.Lee CS, Baughman DM, Lee AY. Deep learning is effective for the classification of OCT images of normal versus age-related macular degeneration. Ophthalmol Retina. (2017) 1:322–7. 10.1016/j.oret.2016.12.009 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Schmidt-Erfurth U, Bogunovic H, Sadeghipour A, Schlegl T, Langs G, Gerendas BS, et al. Machine learning to analyze the prognostic value of current imaging biomarkers in neovascular age-related macular degeneration. Ophthalmol Retina. (2018) 2:24–30. 10.1016/j.oret.2017.03.015 [DOI] [PubMed] [Google Scholar]
- 22.Holz FG, Sadda SR, Staurenghi G, Lindner M, Bird AC, Blodi BA, et al. Imaging protocols in clinical studies in advanced age-related macular degeneration: recommendations from classification of atrophy consensus meetings. Ophthalmology. (2017) 124:464–78. 10.1016/j.ophtha.2016.12.002 [DOI] [PubMed] [Google Scholar]
- 23.Sadda SR, Chakravarthy U, Birch DG, Staurenghi G, Henry EC, Brittain C. Clinical endpoints for the study of geographic atrophy secondary to age-related macular degeneration. Retina. (2016) 36:1806–22. 10.1097/IAE.0000000000001283 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Sadda SR, Guymer R, Holz FG, Schmitz-Valckenberg S, Curcio CA, Bird AC, et al. Consensus definition for atrophy associated with age-related macular degeneration on OCT: classification of atrophy report 3. Ophthalmology. (2018) 125:537–48. 10.1016/j.ophtha.2017.09.028 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 25.Arksey H, O’Malley L. Scoping studies: towards a methodological framework. Int J Soc Res Methodol. (2005) 8:19–32. 10.1080/1364557032000119616 [DOI] [Google Scholar]
- 26.Levac D, Colquhoun H, O’Brien KK. Scoping studies: advancing the methodology. Implement Sci. (2010) 5:69. 10.1186/1748-5908-5-69 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.El Ghazi D, Miere A, Crincoli E, Le HM, Souied EH. In vivo cone-photoreceptor density comparison between eyes with subretinal drusenoid deposits and healthy eyes using high magnification imaging. Int Ophthalmol. (2024) 44:82. 10.1007/s10792-024-03023-x [DOI] [PubMed] [Google Scholar]
- 28.Abdelfattah NS, Zhang H, Boyer DS, Rosenfeld PJ, Feuer WJ, Gregori G, et al. Drusen volume as a predictor of disease progression in patients with late age-related macular degeneration in the fellow eye. Invest Ophthalmol Vis Sci. (2016) 57:1839–46. 10.1167/iovs.15-18572 [DOI] [PubMed] [Google Scholar]
- 29.Pasricha MV, Tai V, Sleiman K, Winter K, Chiu SJ, Farsiu S, et al. Local anatomic precursors to new-onset geographic atrophy in age-related macular degeneration as defined on OCT. Ophthalmol Retina. (2021) 5:396–408. 10.1016/j.oret.2020.12.010 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Sura AA, Chen L, Messinger JD, Swain TA, McGwin G, Freund KB, et al. Measuring the contributions of basal laminar deposit and bruch’s membrane in age-related macular degeneration. Invest Ophthalmol Vis Sci. (2020) 61:19. 10.1167/iovs.61.13.19 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Abraham JR, Jaffe GJ, Kaiser PK, Chiu SJ, Loo J, Farsiu S, et al. Impact of baseline quantitative OCT features on response to risuteganib for the treatment of dry age-related macular degeneration: the importance of outer retinal integrity. Ophthalmol Retina. (2022) 6:1019–27. 10.1016/j.oret.2022.05.002 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Bell J, Whitney J, Cetin H, Le T, Cardwell N, Srivasatava SK, et al. Validation of inter-reader agreement/consistency for quantification of ellipsoid zone integrity and Sub-RPE compartmental features across retinal diseases. Diagnostics (Basel). (2024) 14:2395. 10.3390/diagnostics14212395 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Birner K, Reiter GS, Steiner I, Deák G, Mohamed H, Schürer-Waldheim S, et al. Topographic and quantitative correlation of structure and function using deep learning in subclinical biomarkers of intermediate age-related macular degeneration. Sci Rep. (2024) 14:28165. 10.1038/s41598-024-72522-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Birner K, Reiter GS, Steiner I, Zarghami A, Sadeghipour A, Schürer-Waldheim S, et al. Structure-function correlation of deep-learning quantified ellipsoid zone and retinal pigment epithelium loss and microperimetry in geographic atrophy. Invest Ophthalmol Vis Sci. (2025) 66:26. 10.1167/iovs.66.3.26 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Bogunovic H, Montuoro A, Baratsits M, Karantonis MG, Waldstein SM, Schlanitz F, et al. Machine learning of the progression of intermediate age-related macular degeneration based on OCT imaging. Invest Ophthalmol Vis Sci. (2017) 58:BIO141–50. 10.1167/iovs.17-21789 [DOI] [PubMed] [Google Scholar]
- 36.Borrelli E, Costanzo E, Parravano M, Viggiano P, Varano M, Giorno P, et al. Impact of bleaching on photoreceptors in different intermediate AMD phenotypes. Transl Vis Sci Technol. (2019) 8:5. 10.1167/tvst.8.6.5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Borrelli E, Sacconi R, Zuccaro B, Cavalleri M, Bordato A, Zucchiatti I, et al. Photoreceptor alteration in intermediate age-related macular degeneration. Sci Rep. (2020) 10:21036. 10.1038/s41598-020-78201-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38.Carvajal N, Yang D, Nava K, Kedia A, Keenan JD, Yiu G, et al. Intergrader agreement in grading optical coherence tomography morphologic features in eyes with intermediate nonexudative age-related macular degeneration. Transl Vis Sci Technol. (2024) 13:3. 10.1167/tvst.13.8.3 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Cedro L, Hoffmann L, Hatz K. Geographic atrophy in AMD: prognostic factors based on long-term follow-up. Ophthalmic Res. (2023) 66:791–800. 10.1159/000530418 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Cheung R, Trinh M, Nivison-Smith L. Retinal pigment epithelium curvature can predict late age-related macular degeneration. Invest Ophthalmol Vis Sci. (2024) 65:7. 10.1167/iovs.65.12.7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41.Choi H, Corradetti G, Lindenberg S, Karamat AN, Oncel D, Liu H, et al. Incomplete RPE and outer retinal atrophy (iRORA) development in eyes with fellow-eye neovascular age-related macular degeneration. Ophthalmic Surg Lasers Imaging Retina. (2025) 56:274–9. 10.3928/23258160-20250108-01 [DOI] [PubMed] [Google Scholar]
- 42.Cicinelli MV, Barlocci E, Giuffrè C, Rissotto F, Introini U, Bandello F. Integrating machine learning and traditional survival analysis to identify key predictors of foveal involvement in geographic atrophy. Invest Ophthalmol Vis Sci. (2024) 65:10. 10.1167/iovs.65.5.10 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 43.Clemens CR, Alten F, Heiduschka P, Eter N. Morphology score as a marker of retinal function in drusenoid pigment epithelial detachment. Retina. (2015) 35:1351–9. 10.1097/IAE.0000000000000473 [DOI] [PubMed] [Google Scholar]
- 44.Corbelli E, Sacconi R, Rabiolo A, Mercuri S, Carnevali A, Querques L, et al. Optical coherence tomography angiography in the evaluation of geographic atrophy area extension. Invest Ophthalmol Vis Sci. (2017) 58:5201–8. 10.1167/iovs.17-22508 [DOI] [PubMed] [Google Scholar]
- 45.Corvi F, Corradetti G, Laiginhas R, Liu J, Gregori G, Rosenfeld PJ, et al. Comparison between B-scan and en face images for incomplete and complete retinal pigment epithelium and outer retinal atrophy. Ophthalmol Retina. (2023) 7:999–1009. 10.1016/j.oret.2023.07.003 [DOI] [PubMed] [Google Scholar]
- 46.Coulibaly LM, Reiter GS, Fuchs P, Lachinov D, Leingang O, Vogl WD, et al. Progression dynamics of early versus later stage atrophic lesions in nonneovascular age-related macular degeneration using quantitative OCT biomarker segmentation. Ophthalmol Retina. (2023) 7:762–70. 10.1016/j.oret.2023.05.004 [DOI] [PubMed] [Google Scholar]
- 47.Ehlers JP, McConville C, Yordi S, Cetin H, Cakir Y, Kalra G, et al. Correlation between blue fundus autofluorescence and SD-OCT measurements of geographic atrophy in dry age-related macular degeneration. Am J Ophthalmol. (2024) 266:92–101. 10.1016/j.ajo.2024.04.031 [DOI] [PubMed] [Google Scholar]
- 48.Erb BM, Botros E, Saunders TF, Haas AM, Voland R, Linderman R, et al. Investigating macular tissue integrity index as a novel biomarker in geographic atrophy. Ophthalmol Sci. (2025) 5:100871. 10.1016/j.xops.2025.100871 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Etheridge T, Liu Z, Nalbandyan M, Cleland S, Blodi BA, Mares JA, et al. Association of macular thickness with age and age-related macular degeneration in the carotenoids in age-related eye disease study 2 (CAREDS2), an ancillary study of the women’s health initiative. Transl Vis Sci Technol. (2021) 10:39. 10.1167/tvst.10.2.39 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 50.Farinha C, Silva AL, Coimbra R, Nunes S, Cachulo ML, Marques JP, et al. Retinal layer thicknesses and neurodegeneration in early age-related macular degeneration: insights from the Coimbra Eye Study. Graefes Arch Clin Exp Ophthalmol. (2021) 259:2545–57. 10.1007/s00417-021-05140-0 [DOI] [PubMed] [Google Scholar]
- 51.Fasih-Ahmad S, Wang Z, Mishra Z, Vatanatham C, Clark ME, Swain TA, et al. Potential structural biomarkers in 3D images validated by the first functional biomarker for early age-related macular degeneration - ALSTAR2 baseline. Invest Ophthalmol Vis Sci. (2024) 65:1. 10.1167/iovs.65.2.1 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Flores R, Fradinho AC, Pereira RS, Mendes JM, Seabra MC, Tenreiro S, et al. Identifying imaging predictors of intermediate age-related macular degeneration progression. Transl Vis Sci Technol. (2023) 12:22. 10.1167/tvst.12.7.22 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Flynn OJ, Cukras CA, Jeffrey BG. Characterization of rod function phenotypes across a range of age-related macular degeneration severities and subretinal drusenoid deposits. Invest Ophthalmol Vis Sci. (2018) 59:2411–21. 10.1167/iovs.17-22874 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Fragiotta S, Costanzo E, Viggiano P, De Geronimo D, Scuderi G, Varano M, et al. Functional correlates of outer retina remodeling in intermediate age-related macular degeneration using microperimetry. Invest Ophthalmol Vis Sci. (2022) 63:16. 10.1167/iovs.63.3.16 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Frank-Publig S, Bogunovic H, Birner K, Gumpinger M, Fuchs P, Coulibaly LM, et al. Quantifications of outer retinal bands in geographic atrophy by comparing superior axial resolution and conventional OCT. Invest Ophthalmol Vis Sci. (2025) 66:65. 10.1167/iovs.66.4.65 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Futterknecht S, Anders P, Mai J, Riedl S, Hall U, Gabrani C, et al. Targeted microperimetry grids for focal lesions in intermediate AMD: PINNACLE study report 7. Invest Ophthalmol Vis Sci. (2025) 66:6. 10.1167/iovs.66.2.6 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 57.Gallagher D, Kalra G, Rasheed MA, Vupparaboina KK, Singh SR, Chhablani J. Long-term retinal changes in progressive geographic atrophy. Eur J Ophthalmol. (2022) 32:1687–93. 10.1177/11206721211035636 [DOI] [PubMed] [Google Scholar]
- 58.Ghoshal R, Sharanjeet-Kaur S, Mohamad Fadzil N, Mutalib HA, Ghosh S, Ngah NF, et al. Correlation between visual functions and retinal morphology in eyes with early and intermediate age-related macular degeneration. Int J Environ Res Public Health. (2020) 17:6379. 10.3390/ijerph17176379 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 59.Goerdt L, Swain TA, Kar D, McGwin G, Berlin A, Clark ME, et al. Band visibility in high-resolution optical coherence tomography assessed with a custom review tool and updated, histology-derived nomenclature. Transl Vis Sci Technol. (2024) 13:19. 10.1167/tvst.13.12.19 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 60.Griffin SM, Jia Y, Johnson AJ, Antony BJ, McDonald HR, Johnson RN, et al. Directional reflectivity of the ellipsoid zone in dry age-related macular degeneration. Ophthalmic Surg Lasers Imaging Retina. (2021) 52:145–52. 10.3928/23258160-20210302-05 [DOI] [PubMed] [Google Scholar]
- 61.Hanna V, Oakley J, Russakoff D, Choudhry N. Effects of subthreshold nanosecond laser therapy in age-related macular degeneration using artificial intelligence (STAR-AI Study). PLoS One. (2021) 16:e0250609. 10.1371/journal.pone.0250609 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 62.Heckenlaible NJ, Toomey CB, Handa JTOCT. Changes observed during the progression of early age-related macular degeneration. Ophthalmol Sci. (2024) 5:100615. 10.1016/j.xops.2024.100615 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 63.Heiferman M, Fernandes JK, Munk MR, Mirza R, Jampol LM, Fawzi AA. Reticular pseudodrusen on infrared reflectance are topographically distinct from subretinal drusenoid deposits on en face optical coherence tomography. Invest Ophthalmol Visual Sci. (2015) 56:5145. 10.1097/IAE.0000000000000666 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 64.Ho CYD, Wu Z, Turpin A, Lawson DJ, Luu CD, McKendrick AM, et al. Tablet-based retinal function test in neovascular age-related macular degeneration eyes and at-risk fellow eye. Transl Vis Sci Technol. (2018) 7:2. 10.1167/tvst.7.2.2 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 65.Hong S, Choi M, Yun C, Kim SW. Retinal vessel density in age-related macular degeneration patients with geographic atrophy. J Clin Med. (2022) 11:1501. 10.3390/jcm11061501 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 66.Itoh Y, Vasanji A, Ehlers JP. Volumetric ellipsoid zone mapping for enhanced visualisation of outer retinal integrity with optical coherence tomography. Br J Ophthalmol. (2016) 100:295–9. 10.1136/bjophthalmol-2015-307105 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 67.Kalra G, Cetin H, Whitney J, Yordi S, Cakir Y, McConville C, et al. Machine learning-based automated detection and quantification of geographic atrophy and hypertransmission defects using spectral domain optical coherence tomography. J Pers Med. (2022) 13:37. 10.3390/jpm13010037 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 68.Kalra G, Cetin H, Whitney J, Yordi S, Cakir Y, McConville C, et al. Automated identification and segmentation of ellipsoid zone at-risk using deep learning on SD-OCT for predicting progression in Dry AMD. Diagnostics (Basel). (2023) 13:1178. 10.3390/diagnostics13061178 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 69.Kar SS, Cetin H, Abraham J, Srivastava SK, Madabhushi A, Ehlers JP. Combination of optical coherence tomography-derived shape and texture features are associated with development of sub-foveal geographic atrophy in dry AMD. Sci Rep. (2024) 14:17602. 10.1038/s41598-024-68259-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 70.Liermann YN, Behning C, Isselmann B, Schmid M, Dunbar HMP, Luhmann UFO, et al. Ellipsoid zone reflectivity as a functional imaging biomarker for age-related macular degeneration: a MACUSTAR study report. Sci Rep. (2025) 15:20093. 10.1038/s41598-025-00735-7 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 71.Mahmoudi A, Corradetti G, Emamverdi M, Lindenberg S, He Y, Oncel D, et al. Atrophic lesions associated with age-related macular degeneration: high-resolution versus standard OCT. Ophthalmol Retina. (2024) 8:367–75. 10.1016/j.oret.2023.10.011 [DOI] [PubMed] [Google Scholar]
- 72.Mai J, Reiter GS, Riedl S, Vogl WD, Sadeghipour A, Foos E, et al. Quantitative comparison of automated OCT and conventional FAF-based geographic atrophy measurements in the phase 3 OAKS/DERBY trials. Sci Rep. (2024) 14:20531. 10.1038/s41598-024-71496-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- 73.Mai J, Reiter GS, Riedl S, Vogl WD, Sadeghipour A, McKeown A, et al. Dynamics of the EZ/RPE loss ratio on OCT over time during geographic atrophy progression and treatment with pegcetacoplan. Invest Ophthalmol Vis Sci. (2025) 66:48. 10.1167/iovs.66.11.48 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 74.Morelle O, Wintergerst MWM, Finger RP, Schultz T. Accurate drusen segmentation in optical coherence tomography via order-constrained regression of retinal layer heights. Sci Rep. (2023) 13:8162. 10.1038/s41598-023-35230-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 75.Müller PL, Liefers B, Treis T, Rodrigues FG, Olvera-Barrios A, Paul B, et al. Reliability of retinal pathology quantification in age-related macular degeneration: implications for clinical trials and machine learning applications. Transl Vis Sci Technol. (2021) 10:4. 10.1167/tvst.10.3.4 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 76.Pfau M, Sahu S, Rupnow RA, Romond K, Millet D, Holz FG, et al. Probabilistic forecasting of anti-VEGF treatment frequency in neovascular age-related macular degeneration. Transl Vis Sci Technol. (2021) 10:30. 10.1167/tvst.10.7.30 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 77.Pfau M, Schmitz-Valckenberg S, Ribeiro R, Safaei R, McKeown A, Fleckenstein M, et al. Association of complement C3 inhibitor pegcetacoplan with reduced photoreceptor degeneration beyond areas of geographic atrophy. Sci Rep. (2022) 12:17870. 10.1038/s41598-022-22404-9 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 78.Pfau M, von der Emde L, de Sisternes L, Hallak JA, Leng T, Schmitz-Valckenberg S, et al. Progression of photoreceptor degeneration in geographic atrophy secondary to age-related macular degeneration. JAMA Ophthalmol. (2020) 138:1026–34. 10.1001/jamaophthalmol.2020.2914 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 79.Pfau M, von der Emde L, Dysli C, Möller PT, Thiele S, Lindner M, et al. Determinants of cone and rod functions in geographic atrophy: AI-based structure-function correlation. Am J Ophthalmol. (2020) 217:162–73. 10.1016/j.ajo.2020.04.003 [DOI] [PubMed] [Google Scholar]
- 80.Pfau M, von der Emde L, Dysli C, Thiele S, Möller PT, Lindner M, et al. Light sensitivity within areas of geographic atrophy secondary to age-related macular degeneration. Invest Ophthalmol Vis Sci. (2019) 60:3992–4001. 10.1167/iovs.19-27178 [DOI] [PubMed] [Google Scholar]
- 81.Prenner V, Reiter GS, Fuchs P, Birner K, Frank S, Coulibaly L, et al. Advancing the visibility of outer retinal integrity in neovascular age-related macular degeneration with high-resolution OCT. Can J Ophthalmol. (2025) 60:42–9. 10.1016/j.jcjo.2024.05.014 [DOI] [PubMed] [Google Scholar]
- 82.Qu J, Velaga SB, Hariri AH, Nittala MG, Sadda S. Classification and quantitative analysis of geographic atrophy junctional zone using spectral domain optical coherence tomography. Retina. (2018) 38:1456–63. 10.1097/IAE.0000000000001824 [DOI] [PubMed] [Google Scholar]
- 83.Riedl S, Cooney L, Grechenig C, Sadeghipour A, Pablik E, Seaman JW, et al. Topographic analysis of photoreceptor loss correlated with disease morphology in neovascular age-related macular degeneration. Retina. (2020) 40:2148–57. 10.1097/IAE.0000000000002717 [DOI] [PubMed] [Google Scholar]
- 84.Riedl S, Schmidt-Erfurth U, Rivail A, Birner K, Mai J, Vogl WD, et al. Sequence of morphological changes preceding atrophy in intermediate AMD using deep learning. Invest Ophthalmol Vis Sci. (2024) 65:30. 10.1167/iovs.65.8.30 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 85.Rogala J, Zangerl B, Assaad N, Fletcher EL, Kalloniatis M, Nivison-Smith L. In vivo quantification of retinal changes associated with drusen in age-related macular degeneration. Invest Ophthalmol Vis Sci. (2015) 56:1689–700. 10.1167/iovs.14-16221 [DOI] [PubMed] [Google Scholar]
- 86.Russakoff DB, Lamin A, Oakley JD, Dubis AM, Sivaprasad S. Deep learning for prediction of AMD progression: a pilot study. Invest Ophthalmol Vis Sci. (2019) 60:712–22. 10.1167/iovs.18-25325 [DOI] [PubMed] [Google Scholar]
- 87.Sadigh S, Luo X, Cideciyan AV, Sumaroka A, Boxley SL, Hall LM, et al. Drusen and photoreceptor abnormalities in African-Americans with intermediate non-neovascular age-related macular degeneration. Curr Eye Res. (2015) 40:398–406. 10.3109/02713683.2014.925934 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Saeed A, Gin C, Hodgson LAB, Jannaud M, Hadoux X, Glover EK, et al. Local OCT structural correlates of deep visual sensitivity defects in early atrophic age-related macular degeneration. Ophthalmol Retina. (2025) 9:412–20. 10.1016/j.oret.2024.12.007 [DOI] [PubMed] [Google Scholar]
- 89.Sarici K, Abraham JR, Sevgi DD, Lunasco L, Srivastava SK, Whitney J, et al. Risk classification for progression to subfoveal geographic atrophy in dry age-related macular degeneration using machine learning-enabled outer retinal feature extraction. Ophthalmic Surg Lasers Imaging Retina. (2022) 53:31–9. 10.3928/23258160-20211210-01 [DOI] [PubMed] [Google Scholar]
- 90.Saßmannshausen M, Behning C, Isselmann B, Schmid M, Finger RP, Holz FG, et al. Relative ellipsoid zone reflectivity and its association with disease severity in age-related macular degeneration: a MACUSTAR study report. Sci Rep. (2022) 12:14933. 10.1038/s41598-022-18875-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 91.Saßmannshausen M, Steinberg JS, Fimmers R, Pfau M, Thiele S, Fleckenstein M, et al. Structure-function analysis in patients with intermediate age-related macular degeneration. Invest Ophthalmol Vis Sci. (2018) 59:1599–608. 10.1167/iovs.17-22712 [DOI] [PubMed] [Google Scholar]
- 92.Saßmannshausen M, Vaisband M, von der Emde L, Sloan KR, Hasenauer J, Holz FG, et al. Hyper-reflective foci in intermediate age-related macular degeneration: spatial abundance and impact on retinal morphology. Invest Ophthalmol Vis Sci. (2023) 64:20. 10.1167/iovs.64.1.20 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 93.Savastano MC, Falsini B, Ferrara S, Scampoli A, Piccardi M, Savastano A, et al. Subretinal pigment epithelium illumination combined with focal electroretinogram and visual acuity for early diagnosis and prognosis of non-exudative age-related macular degeneration: new insights for personalized medicine. Transl Vis Sci Technol. (2022) 11:35. 10.1167/tvst.11.1.35 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 94.Sayegh RG, Sacu S, Dunavölgyi R, Kroh ME, Roberts P, Mitsch C, et al. Geographic atrophy and foveal-sparing changes related to visual acuity in patients with dry age-related macular degeneration over time. Am J Ophthalmol. (2017) 179:118–28. 10.1016/j.ajo.2017.03.031 [DOI] [PubMed] [Google Scholar]
- 95.Schaal KB, Freund KB, Litts KM, Zhang Y, Messinger JD, Curcio CA. Outer retinal tubulation in advanced age-related macular degeneration: optical coherence tomographic findings correspond to histology. Retina. (2015) 35:1339–50. 10.1097/IAE.0000000000000471 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 96.Schmidt-Erfurth U, Mai J, Reiter GS, Riedl S, Vogl WD, Sadeghipour A, et al. Disease activity and therapeutic response to pegcetacoplan for geographic atrophy identified by deep learning-based analysis of OCT. Ophthalmology. (2025) 132:181–93. 10.1016/j.ophtha.2024.08.017 [DOI] [PubMed] [Google Scholar]
- 97.Schmitz-Valckenberg S, Saßmannshausen M, Braun M, Steffen V, Gao SS, Honigberg L, et al. Interreader agreement and longitudinal progression of incomplete/complete retinal pigment epithelium and outer retinal atrophy in age-related macular degeneration. Ophthalmol Retina. (2023) 7:1059–68. 10.1016/j.oret.2023.07.021 [DOI] [PubMed] [Google Scholar]
- 98.Schweighofer J, Birner K, Mohamed H, Schrittwieser J, Bogunovic H, Reiter GS, et al. Benchmarking test-retest variability in microperimetry for intermediate age-related macular degeneration using MP-3 and MAIA. Can J Ophthalmol. (2025) 60:e879–87. 10.1016/j.jcjo.2025.05.002 [DOI] [PubMed] [Google Scholar]
- 99.Song X, Xu Q, Li H, Fan Q, Zheng Y, Zhang Q, et al. Automatic quantification of retinal photoreceptor integrity to predict persistent disease activity in neovascular age-related macular degeneration using deep learning. Front Neurosci. (2022) 16:952735. 10.3389/fnins.2022.952735 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 100.Steinberg JS, Saßmannshausen M, Fleckenstein M, Fimmers R, Oishi A, Holz FG, et al. Correlation of partial outer retinal thickness with scotopic and mesopic fundus-controlled perimetry in patients with reticular drusen. Am J Ophthalmol. (2016) 168:52–61. 10.1016/j.ajo.2016.04.025 [DOI] [PubMed] [Google Scholar]
- 101.Sulzbacher F, Roberts P, Munk MR, Kaider A, Kroh ME, Sacu S, et al. Relationship of retinal morphology and retinal sensitivity in the treatment of neovascular age-related macular degeneration using aflibercept. Invest Ophthalmol Vis Sci. (2014) 56:1158–67. 10.1167/iovs.14-14298 [DOI] [PubMed] [Google Scholar]
- 102.Inanc Tekin M, Sekeroglu MA, Demirtas C, Tekin K, Doguizi S, Bayraktar S, et al. Brain-derived neurotrophic factor in patients with age-related macular degeneration and its correlation with retinal layer thicknesses. Invest Ophthalmol Vis Sci. (2018) 59:2833–40. 10.1167/iovs.18-24030 [DOI] [PubMed] [Google Scholar]
- 103.Tepelus TC, Hariri AH, Al-Sheikh M, Sadda SR. Correlation between mesopic retinal sensitivity and optical coherence tomographic metrics of the outer retina in patients with non-atrophic dry age-related macular degeneration. Ophthalmic Surg Lasers Imaging Retina. (2017) 48:312–8. 10.3928/23258160-20170329-05 [DOI] [PubMed] [Google Scholar]
- 104.Thiele S, Isselmann B, Pfau M, Holz FG, Schmitz-Valckenberg S, Wu Z, et al. Validation of an automated quantification of relative ellipsoid zone reflectivity on spectral domain-optical coherence tomography images. Transl Vis Sci Technol. (2020) 9:17. 10.1167/tvst.9.11.17 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 105.Thiele S, Wu Z, Isselmann B, Pfau M, Guymer RH, Luu CD. Natural history of the relative ellipsoid zone reflectivity in age-related macular degeneration. Ophthalmol Retina. (2022) 6:1165–72. 10.1016/j.oret.2022.06.001 [DOI] [PubMed] [Google Scholar]
- 106.Trinh M, Eshow N, Alonso-Caneiro D, Kalloniatis M, Nivison-Smith L. Reticular pseudodrusen are associated with more advanced para-central photoreceptor degeneration in intermediate age-related macular degeneration. Invest Ophthalmol Vis Sci. (2022) 63:12. 10.1167/iovs.63.11.12 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 107.Trinh M, Kalloniatis M, Alonso-Caneiro D, Nivison-Smith L. High-density optical coherence tomography analysis provides insights into early/intermediate age-related macular degeneration retinal layer changes. Invest Ophthalmol Vis Sci. (2022) 63:36. 10.1167/iovs.63.5.36 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 108.Trinh M, Khou V, Kalloniatis M, Nivison-Smith L. Location-specific thickness patterns in intermediate age-related macular degeneration reveals anatomical differences in multiple retinal layers. Invest Ophthalmol Vis Sci. (2021) 62:13. 10.1167/iovs.62.13.13 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 109.van Romunde SHM, Polito A, Peroglio Deiro A, Bertazzi L, Guerriero M, Pertile G. Morphological changes in the diseased retina on a healthy choroid-retinal pigment epithelial complex after full macular translocation for exudative age-related macular degeneration. Acta Ophthalmol. (2019) 97:e283–9. 10.1111/aos.13880 [DOI] [PubMed] [Google Scholar]
- 110.Vogl WD, Bogunović H, Waldstein SM, Riedl S, Schmidt-Erfurth U. Spatio-temporal alterations in retinal and choroidal layers in the progression of age-related macular degeneration (AMD) in optical coherence tomography. Sci Rep. (2021) 11:5743. 10.1038/s41598-021-85110-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- 111.von der Emde L, Pfau M, Dysli C, Thiele S, Möller PT, Lindner M, et al. Artificial intelligence for morphology-based function prediction in neovascular age-related macular degeneration. Sci Rep. (2019) 9:11132. 10.1038/s41598-019-47565-y [DOI] [PMC free article] [PubMed] [Google Scholar]
- 112.Wang DL, Agee J, Mazzola M, Sacconi R, Querques G, Weinberg AD, et al. Outer retinal thickness and fundus autofluorescence in geographic atrophy. Ophthalmol Retina. (2019) 3:1035–44. 10.1016/j.oret.2019.07.016 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 113.Weber S, Simon R, Schwanengel LS, Curcio CA, Augsten R, Meller D, et al. Fluorescence lifetime and spectral characteristics of subretinal drusenoid deposits and their predictive value for progression of age-related macular degeneration. Invest Ophthalmol Vis Sci. (2022) 63:23. 10.1167/iovs.63.13.23 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 114.Woronkowicz M, Lightman S, Tomkins-Netzer O. The prognostic value of total macular external limiting membrane and ellipsoid zone damage for clinical outcome in treatment-resistant neovascular age-related macular degeneration. Graefes Arch Clin Exp Ophthalmol. (2020) 258:2373–8. 10.1007/s00417-020-04869-4 [DOI] [PubMed] [Google Scholar]
- 115.Wu Z, Blodi BA, Holz FG, Jaffe GJ, Liakopoulos S, Sadda SR, et al. OCT-defined atrophic age-related macular degeneration changes associated with deep visual sensitivity losses: a multicenter study. Ophthalmol Sci. (2025) 5:100884. 10.1016/j.xops.2025.100884 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 116.Wu Z, De Zanet S, Blair JPM, Guymer RH. Loss of OCT outer retinal bands as potential clinical trial endpoints in intermediate age-related macular degeneration. Ophthalmol Sci. (2025) 5:100769. 10.1016/j.xops.2025.100769 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 117.Yang S, Gao Z, Qiu H, Zuo C, Mi L, Xiao H, et al. Low-reflectivity drusen with overlying RPE damage revealed by spectral-domain OCT: hint for the development of age-related macular degeneration. Front Med (Lausanne). (2021) 8:706502. 10.3389/fmed.2021.706502 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 118.Yordi S, Cakir Y, Cetin H, Talcott KE, Srivastava SK, Hu J, et al. Bacillary layer detachment in neovascular age-related macular degeneration from a phase III clinical trial. Ophthalmol Retina. (2024) 8:754–64. 10.1016/j.oret.2024.02.007 [DOI] [PubMed] [Google Scholar]
- 119.Yordi S, Cakir Y, Kalra G, Cetin H, Hu M, Abraham J, et al. Ellipsoid zone integrity and visual function in dry age-related macular degeneration. J Pers Med. (2024) 14:543. 10.3390/jpm14050543 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 120.Yordi S, Sarici K, Cetin H, Lunasco LM, Le TK, Sevgi DD, et al. Bacillary detachment in neovascular age-related macular degeneration: incidence, clinical features, and response to anti-VEGF therapy. Ophthalmol Retina. (2022) 6:1061–9. 10.1016/j.oret.2022.05.022 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 121.Yoshida K, Anegondi N, Pely A, Zhang M, Debraine F, Ramesh K, et al. Deep learning approaches to predict geographic atrophy progression using three-dimensional OCT imaging. Transl Vis Sci Technol. (2025) 14:11. 10.1167/tvst.14.2.11 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 122.Zhuang X, Pu J, Li M, Mi L, Zhang X, Ji Y, et al. Association between three-dimensional morphological features and functional indicators of neovascular age-related macular degeneration. Microvasc Res. (2024) 155:104716. 10.1016/j.mvr.2024.104716 [DOI] [PubMed] [Google Scholar]
- 123.Yang J, Zhang Q, Motulsky EH, Thulliez M, Shi Y, Lyu C. Two-year risk of exudation in eyes with nonexudative age-related macular degeneration and subclinical neovascularization detected with swept source optical coherence tomography angiography. Am J Ophthalmol. (2019) 208:1–11. 10.1016/j.ajo.2019.06.017 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 124.Sassmannshausen M, Pfau M, Thiele S, Fimmers R, Steinberg JS, Fleckenstein M, et al. Longitudinal analysis of structural and functional changes in presence of reticular pseudodrusen associated with age-related macular degeneration. Invest Ophthalmol Vis Sci. (2020) 61:19. 10.1167/iovs.61.10.19 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 125.Saeed A, Guymer RH, Hadoux X, Jannaud M, Dang D, Hodgson LAB, et al. Customized evaluation of progressive visual sensitivity loss in geographic atrophy to improve the power of clinical trials. Ophthalmol Sci. (2025) 5:100763. 10.1016/j.xops.2025.100763 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 126.Guymer RH, Rosenfeld PJ, Curcio CA, Holz FG, Staurenghi G, Freund KB, et al. Incomplete retinal pigment epithelial and outer retinal atrophy in age-related macular degeneration: classification of atrophy meeting report 4. Ophthalmology. (2020) 127:394–409. 10.1016/j.ophtha.2019.09.035 [DOI] [PMC free article] [PubMed] [Google Scholar]
- 127.Holz FG, Strauss EC, Schmitz-Valckenberg S, van Lookeren Campagne M. Geographic atrophy: clinical features and potential therapeutic approaches. Ophthalmology. (2014) 121:1079–91. 10.1016/j.ophtha.2013.11.023 [DOI] [PubMed] [Google Scholar]
- 128.Tricco AC, Lillie E, Zarin W, O’Brien KK, Colquhoun H, Levac D, et al. PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation. Ann Intern Med. (2018) 169:467–73. 10.7326/M18-0850 [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.