Skip to main content
Imaging Neuroscience logoLink to Imaging Neuroscience
. 2026 Jul 27;4:IMAG.a.1317. doi: 10.1162/IMAG.a.1317

Bayesian insights into exchange and restriction in gray matter diffusion MRI

Maëliss Jallais 1,2,*, Quentin Uhl 3,4, Tommaso Pavan 3,4, Malwina Molendowska 1, Derek K Jones 1, Ileana Jelescu 3,4, Marco Palombo 1,2
PMCID: PMC13409282  PMID: 42524206

Abstract

Biophysical models in diffusion MRI (dMRI) hold promise for characterizing gray matter tissue microstructure. Yet, the reliability of their parameter estimates remains largely under studied, especially in models that incorporate water exchange. In this study, we investigate the accuracy, precision, and presence of degeneracy of two recently proposed gray matter models, NEXI and SANDIX, using established acquisition protocols, on both simulated and in vivo data. We employ µGUIDE, a Bayesian inference framework based on deep learning, to quantify parameter uncertainty and detect degeneracies, enabling a more interpretable assessment of model fits. Our results show that while some microstructural parameters, such as extra-cellular diffusivity and neurite signal fraction, are robustly estimated, others, including exchange time and soma radius, are often associated with high uncertainty and estimation bias, particularly under realistic noise conditions and reduced acquisition protocols. Comparison with non-linear least squares fitting highlights the critical advantage of uncertainty-aware methods: the ability to flag and filter out unreliable estimates. Together, these findings emphasize the need to report uncertainty and account for model degeneracies when interpreting model-based estimates. Our study advocates for the integration of probabilistic fitting approaches into imaging pipelines to improve reproducibility and biological interpretability.

Keywords: diffusion MRI, gray matter, water exchange, Bayesian inference, uncertainty, degeneracy

1. Introduction

Diffusion-weighted magnetic resonance imaging (dMRI) is a promising technique for characterizing brain microstructure in vivo using a paradigm called microstructure imaging (Alexander et al., 2017; Jelescu et al., 2020; Novikov, Fieremans, et al., 2018). By fitting biophysical models to dMRI signals, quantitative measures that reflect histologically meaningful features of tissue microstructure can be estimated.

Brain white matter (WM) microstructure has been extensively studied, and commonly used biophysical models typically include two or three non-exchanging compartments under a Gaussian diffusion assumption (Panagiotaki et al., 2012): axons modeled as a collection of zero-radius cylinders (namely “sticks”), following an orientation dispersion function (ODF); an anisotropic extra-neurite space modeled by an ellipsoid aligned with the main stick bundle direction; and, when needed, cerebrospinal fluid (CSF) contamination, included as a free water component. Numerous implementations have been proposed, varying the shape of the ODF, assumptions about the extra-neurite space diffusion, or introducing simplifying assumptions between the compartmental diffusivities (Fieremans et al., 2011; Jespersen et al., 2010; Novikov, Fieremans, et al., 2018; Novikov, Veraart, et al., 2018; Reisert et al., 2017; Zhang et al., 2012).

For a collection of impermeable sticks, the directionally averaged signal S is expected to follow a power-law decay for high b-values b, with S∝b−1/2 (Lee et al., 2020; Veraart et al., 2019). While WM approximately follows this behavior, deviations from this power law have been observed, reflecting sensitivity to finite axonal diameters (Veraart et al., 2020) and structural disorder (Fieremans et al., 2016). These deviations are substantially higher in gray matter (GM) (McKinnon et al., 2017; Veraart et al., 2020), indicating that GM microstructure cannot be captured by the same models.

This motivated the development of GM-specific biophysical models. Previous studies have explored multiple mechanisms underlying the distinct high-b behavior observed in GM (Jespersen et al., 2007, 2010; Komlosh et al., 2007; Shemesh & Cohen, 2011; Shemesh et al., 2012; Truong et al., 2014). Three main hypotheses have been proposed to explain the stronger deviation from the stick power law. The first one attributes it to the presence of cell bodies (namely somas) (Fang et al., 2020; Olesen et al., 2022; Palombo et al., 2020), and adds an extra spherical compartment modeling restricted diffusion within somas, such as in the Soma And Neurite Density Imaging (SANDI) model (Palombo et al., 2020). Somas are typically neglected in WM due to their relatively small density (5–10% ex vivo) (M. Andersson et al., 2020; Veraart et al., 2020), but occupy ∼10–20% of gray matter by volume (Motta et al., 2019; Shapson-Coe et al., 2021). Another approach suggests to account for exchange between the intra- and extra-neurite space across the neurite membranes, due to low myelination in GM tissue compared with WM, which allows water molecules to cross membrane boundaries and potentially bias measurements that assume impermeable compartments (Jelescu et al., 2022; Olesen et al., 2022). Reported exchange times vary between 3 and 5 ms in ex vivo rat cortex (Olesen et al., 2022), between 10 and 50 ms in in vivo rat cortex (Jelescu et al., 2022) and perfused neonatal mouse spinal cords (Williamson et al., 2019), between 10 and 80 ms in in vivo human cortex (Dong et al., 2025; Uhl, Pavan, Gerold, et al., 2025; Uhl et al., 2024; Veraart et al., 2020), and up to between 100 and 150 ms in astrocyte and neuron cultures (Yang et al., 2018), rat brain (Quirk et al., 2003), and rat brain cortical cultures (Bai et al., 2018). Finally, non-Gaussian diffusion along the dendrites was suggested to break down as a result of structural disorder, such as neurite undulation, beading, and dendritic spines (Chakwizira, Şimşek, et al., 2025; Henriques et al., 2019; Lee et al., 2020; Özarslan et al., 2018; Şimşek et al., 2025).

Recent studies suggest that exchange is the primary mechanism underlying the diffusion time dependence of the signal in both low- and high-b regimes, with the influence of soma becoming more significant at longer diffusion times within the high-b regime (Jelescu et al., 2022; Olesen et al., 2022). To account for these effects, new biophysical models have been proposed, such as the Neurite Exchange Imaging (NEXI) model (Jelescu et al., 2022) and the Standard Model with EXchange (SMEX) (Olesen et al., 2022), which both incorporate water exchange between anisotropic compartments, and the Soma and Neurite Density Imaging with Exchange (SANDIX) model (Dong et al., 2025; Olesen et al., 2022), which extends upon the SANDI model by accounting for both restriction in somas and permeative exchange across the neurites’ membrane (i.e., axons and cell processes), thereby enabling estimation of soma size and fraction in addition to exchange-related parameters.

Nevertheless, increasing model complexity comes at a cost. While models such as SANDIX offer more accurate representations of GM microstructure, they introduce additional parameters and potential degeneracies in the parameter space, making them more difficult to fit robustly (Jallais & Palombo, 2024; Olesen et al., 2022). This challenge is further exacerbated by the choice of the acquisition protocols, where differences in diffusion time (t), gradient strength (g), and b-value sampling directly influence model sensitivity. Protocols used in preclinical imaging benefit from ultra-strong gradients (typically 300–1000 mT/m) and short diffusion times, enabling high sensitivity to microstructural features such as soma and exchange. However, such protocols remain impractical in clinical settings due to time constraints and scanner hardware limitations (typically 20–80 mT/m gradients). Next-generation human MRI scanners equipped with ultra-strong gradient systems (up to 300 mT/m), such as the Connectom (Fan et al., 2014; Huang et al., 2021; Jones et al., 2018) or the MAGNUS (Abad et al., 2025) systems, bridge the gap between preclinical and clinical scanners by enabling acquisitions with short diffusion times and high b-values. While stronger gradients and shorter diffusion times increase sensitivity to microstructure, they do not fully resolve ambiguities between model parameters. Consequently, degeneracies, uncertainties, and trade-offs in parameter estimation must be systematically addressed to validate these models in both research and clinical settings (Afzali et al., 2021; Jallais & Palombo, 2024). While for WM models a proper analysis of model degeneracy has been done (Coelho et al., 2019; Jelescu et al., 2016), for complex GM models accounting for both restriction and exchange, this is still missing.

The goal of this study is to evaluate the fitting quality of SANDIX with both a preclinical and a Connectom acquisition protocol, by leveraging the µGUIDE Bayesian inference framework (Jallais & Palombo, 2024). µGUIDE enables the estimation of posterior distributions, which enable to quantify the fitting quality via an uncertainty measure, and highlight parameter degeneracies. We compare the performance of SANDIX with the simpler model NEXI. Using simulations, we investigate how the acquisition protocol and noise characteristics influence uncertainty and the emergence of degeneracies. We fit both biophysical models to in vivo human data of four healthy volunteers scanned on the high-gradient 3T Connectom scanner. Finally, we demonstrate the importance of incorporating uncertainty and degeneracy into the interpretation of results.

2. Methods

2.1. Biophysical models

In this study, we focus on two biophysical models that explicitly account for permeative exchange between neurites and the extra-cellular space: NEXI (Jelescu et al., 2022) and SANDIX (Olesen et al., 2022) (Fig. 1). While both models are rooted in the principles of the Kärger model (Fieremans et al., 2010; Kärger, 1985), they differ in two key aspects. First, NEXI is a two-compartment model that provides an analytical representation of the diffusion time-dependent signal under the narrow pulse approximation (E. O. Stejskal, 1965; Stejskal & Tanner, 1968). In contrast, SANDIX extends on the three-compartment SANDI model by incorporating permeative exchange between neurites and extra-neurite compartments. This makes it more comprehensive in representing GM tissue microstructure, at the cost of increased fitting complexity. Additionally, while NEXI relies on the narrow pulse approximation, SANDIX is based on a generalization of the Kärger model to arbitrary gradient profiles, as described by Ning et al. (2018), which requires a numerical resolution of an ordinary differential equation (ODE).

Fig. 1.

Two model diagrams compared. NEXI shows neurite sticks radiating outward labeled f_n with intra-neurite diffusivity D_n, extracellular exchange arrow t_ex, and D_e for extracellular space with fraction 1 minus f_n. SANDIX adds a soma sphere labeled f_s, radius r_s, diffusivity D_s, with fractions f_n and 1 minus f_n minus f_s. Legend: n neurites/sticks, s somas/spheres, s extracellular space/Gaussian.

Graphical representation of the considered gray matter biophysical models, with the following parameters: exchange time tex, neurites signal fraction fn, parallel diffusivity Dn∥, extra-cellular diffusivity De, soma signal fraction fs, and soma radius rs.

2.1.1. NEXI

NEXI is a two-compartment biophysical model based on the anisotropic Kärger model for a coherent fiber tract. The Kärger model assumes that the exchange is barrier limited, that is, lc2≪Dn∥·τi−e , where lc is the characteristic size of the intra-neurite compartment, Dn∥ is the parallel diffusivity within neurites, and τi−e is the residence time within the intra-neurite compartment before exchanging to the extra-neurite one (Fieremans et al., 2010; Kärger, 1985). Neurites are modeled as a collection of isotropically oriented sticks, neglecting branching, finite processes, and undulations (Olesen et al., 2022; Palombo et al., 2020), with a signal fraction fn. The extra-neurite space is modeled as isotropic Gaussian diffusion with diffusivity De <Dn∥. Water exchange between these two compartments is captured by a characteristic exchange time tex. The total diffusion signal is modeled as the spherical mean of kernel K:

S¯NEXI(q,t;tex,Dn∥,De,fn) =S|q=0·∫01K(q,t,g·n;tex,Dn∥,De,fn)d(g·n)

with

K(q,t,g⋅n;tex,Dn||,De,fn)=f'e−q2tD'n+(1−f')e−q2tD'e
D'n/e=12Dn+De+1q2tex∓De−Dn+2fn−1q2tex2+4fn(1−fn)q4tex212,
f'=1Dn'−De'[fnDn+(1−fn)De=De'],

where n are the neurite orientations, q is the wave vector along direction g, and Dn≡Dn∥(g·n)2.

The four parameters of interest here are, therefore, tex, Dn∥, De, and fn.

2.1.2. SANDIX

Olesen et al. (2022) proposed a generalization of NEXI to any gradient waveforms (Ning et al., 2018) dubbed Standard Model with EXchange (SMEX). The signal for a gradient direction g and intra-neurite signal fraction fn is defined as

SSMEX(q,t,g·n;tex,Dn∥,De,fn) =S1(t;tex,Dn∥,De,fn)+S2(t;tex,Dn∥,De,fn),

where S1(t;tex,Dn∥,De,fn) and S2(t;tex,Dn∥,De,fn) are obtained by integrating the following ODE:

ddt[S1(t)S2(t)]=  ([−1−fntexfntex1−fntex−fntex]−q2(t)[Dn∥(g·n)200De])[S1(t)S2(t)],

with n designing the orientation of a single stick, q(t)≡γ∫0tg(t′)dt′ and g the magnitude of the diffusion gradient pulse.

SANDIX adds a third compartment of impermeable spheres to SMEX to model soma. Spheres are modeled following the Gaussian Phase Approximation (GPA) (Balinov et al., 1993; Palombo et al., 2020) with radius rs, soma signal fraction fs, and a fixed diffusivity Ds = 3 µm2/ms:

S¯sphere(q,t;Ds,rs)≈exp{−2(γg)2Ds∑m=1∞am−4αm2rs2−2 ×[2δ−2+e−am2DS(Δ−δ)−2e−am2DSδ−2e−αm2DSΔ+e−αm2DS(Δ+δ)αm2DS]}

where δ and Δ are the diffusion pulse width and separation, and αm the mth root of the equation (αrs)−1J32(αrs)=J52(αrs) with Jn(x) the Bessel function of the first kind.

The exchange between somas and neurites is considered negligible at diffusion times below 20 ms (Palombo et al., 2020). Exchange between somas and extracellular water is also neglected due to negligible surface-to-volume ratio of somas relative to neurites and the small soma volume. The resulting direction-averaged signal is the following:

S¯SANDIX(q,t;tex,Dn||,De,fn,rs,fs) =fs⋅S¯sphere(q,t;Ds,rs)+(1−fs)    ⋅S¯SMEX(q,t;tex,Dn||,De,fn1−fs) (1)

This model thus adds two additional parameters compared with NEXI, for a total of six parameters to estimate tex, Dn∥, De, fn, rs, fs.

2.2. Acquisition protocols

We considered two Pulsed Gradient Spin Echo (PGSE) protocols from the literature, both previously used to fit the NEXI and SANDIX models described in Section 2.1. The first protocol is an extensive acquisition designed for ex vivo experiments, originally introduced by Olesen et al. (2022) to present SANDIX. The second protocol is the NEXI 3T Connectom protocol (Uhl et al., 2024), designed to be compatible with in vivo human acquisitions on the Connectom scanner. We present simulation results for both protocols, as well as in vivo results acquired with the NEXI 3T Connectom protocol (see Section 2.5 for details on data acquisition).

2.2.1. Extensive ex vivo acquisition protocol

This acquisition protocol was designed to enable the detection of a stick power law in GM and to explore the signal’s dependence on diffusion time using a 16.4 T Bruker Aeon scanner with a Micro5 probe (yielding gradient amplitudes up to 3000 mT/m). The gradient pulse width was fixed to δ = 4.5 ms and three separation times were considered: Δ = 16, 11, 7.5 ms. For each diffusion time, low b-values were set to 0.1, 0.5, 1, 2, 3, 4, and 5 ms/µm2. Higher b-values were sampled and approximately uniformly spaced in b−1/2 , as follows:

  • Δ = 16 ms: from 0.4 to 0.3 µm/ms1/2 with a spacing of 0.025 µm/ms1/2, and from 0.3 to 0.1 µm/ms1/2 with a spacing of 0.0125 µm/ms1/2, resulting in 21 b-values between 6.25 and 100 ms/µm2.

  • Δ = 11 ms: from 0.4 to 0.125 µm/ms1/2 with a spacing of 0.025 µm/ms1/2, resulting in 12 b-values between 6.25 and 64 ms/µm2.

  • Δ = 7.5 ms: from 0.4 to 0.15 µm/ms1/2 with a spacing of 0.025 µm/ms1/2, resulting in 11 b-values between 6.25 and 44.44 ms/µm2.

Ten sampling directions were used for b-values inferior to 25 ms/µm2, and 30 otherwise.

2.2.2. NEXI 3T connectom protocol

The NEXI 3T Connectom protocol was designed to estimate exchange time on a 3T Siemens Connectom scanner. This protocol consists of a combination of five b-values and four diffusion times, with b-values of 1, 2.5, 4, 6 and 7.5 ms/µm2 with, respectively, 13, 25, 25, 32, and 65 directions, and Δ = 20, 29, 39, and 49 ms. The gradient pulse width was fixed at 9 ms.

2.3. Evaluating model fit, uncertainty, and degeneracies using µGUIDE

To quantitatively assess model fitting quality and identify potential parameter degeneracies, we used µGUIDE (Jallais & Palombo, 2024), a general Bayesian inference framework based on simulation-based inference (Cranmer et al., 2020) that allows to estimate posterior distributions of biophysical model parameters.

µGUIDE is composed of two jointly optimized modules. First, a Multi-Layer Perceptron (MLP) is used to reduce the dimensionality of the input signal. Second, a Neural Posterior Estimator (NPE) approximates the posterior distribution by learning a conditional probability density estimator that minimizes the Kullback–Leibler divergence (Papamakarios & Murray, 2016). The conditional probability density approximators used here belong to a class of neural networks called normalizing flows (Papamakarios et al., 2021), a class of neural networks designed for flexible density estimation. A masked autoregressive flow architecture (Germain et al., 2015; Papamakarios et al., 2017) is implemented in µGUIDE. Further details on the training procedure are provided in Section 2.4.

The posterior distributions produced by µGUIDE provide valuable insights into both the confidence of parameter estimates and the landscape of the solution space. In particular, multi-modal posteriors, which are characterized by multiple distinct peaks, indicate degeneracy, meaning that different parameter combinations can produce equally plausible fits to the observed signal. We extracted three key summary statistics from the estimated posterior distributions:

  • the maximum a posteriori (MAP) estimate, representing the most probable parameter configuration;

  • an uncertainty measure, defined as the interquartile range of the 50% most probable samples, which quantifies the dispersion of the posterior distribution. Lower uncertainty values indicate higher precision in the MAP estimates;

  • the presence of degeneracy.

2.4. Simulation framework and model fitting setup

We generated synthetic dMRI signals across eight experimental conditions: both biophysical models (NEXI and SANDIX, see Section 2.1), each evaluated under the two acquisition protocols (see Section 2.2), with and without the addition of Rician noise.

For each scenario, parameter combinations were randomly sampled within biologically feasible ranges: tex ∈[1,150] ms; fn∈[0.05,0.95] for NEXI and fn∈[0.025,0.90] for SANDIX, fs∈[0.05,0.5]; Dn∥,De∈[0.1,3.0] µm2/ms; and rs∈[1,30] µm. To ensure uniform sampling while enforcing the De<Dn∥ constraint, we followed the transformation method from Jallais & Palombo, (2024); Jallais et al. (2022), using two independent variables u0 and u1∼U(0,1):

{Dn∥=(3.0−0.1)2·u0+0.1De=(Dn∥−0.1)·u1+0.1.     

Training was performed using the uniform u0 and u1, and transformed back to Dn∥ and De after inference. All parameters are normalized within the µGUIDE framework for inference.

To mimic acquired signals, we added Rician noise with a median signal-to-noise ratio (SNR) of 36, based on empirical noise distributions estimated using MP-PCA (Veraart et al., 2016) on the Connectom acquisitions (see Sections 2.5.1 & 2.5.2). Both noiseless and noisy datasets were used to assess the impact of noise on parameter estimation and number of degeneracies.

µGUIDE was trained separately for each experimental condition using 7·105 simulations. Using larger sets did not provide significant improvements, while required more time to train. A total of 5% of the simulations were randomly selected for validation. µGUIDE’s MLP module was used to reduce the input dimension to 14 features for NEXI and 22 features for SANDIX. These numbers were selected as optimal after preliminary testing in which the number of MLP features was varied between 5 and 30. The network was trained using a learning rate of 10−3, a minibatch size of 128, and early stopping after 50 epochs if no improvement in validation loss was obtained. A fine-tuning phase followed, using a learning rate of 10−4 and starting from the best checkpoint.

For inference, parameters were estimated independently for each signal by drawing 50,000 samples from the learned conditional posterior via rejection sampling, following the default value in µGUIDE’s implementation. This procedure enables recovery of the full posterior distribution for each model parameter. For each estimated posterior distribution, we estimated the MAP and uncertainty, and flagged degenerate posterior distributions.

2.5. dMRI Data

The study was approved by the School of Psychology Ethics Committee at Cardiff University. Written informed consent was obtained from all participants.

2.5.1. Data acquisition

We fitted NEXI and SANDIX on data from four healthy volunteers (two of whom rescanned on a different day) scanned following the NEXI 3T Connectom protocol (Uhl et al., 2024) on a 3T Siemens Connectom MRI scanner with a gradient amplitude of 300 mT/m (Siemens Heathineers, Erlangen, Germany). Diffusion-weighted images were acquired following the sequence parameters presented in Section 2.2.2. In total, 15 images at b = 0 ms/µm2 per Δ were also acquired. The other parameters were kept fixed: TE/TR = 76/3700 ms, FOV = 216 × 216 mm2, 1.8-mm isotropic resolution, partial Fourier = 0.75, GRAPPA = 2, and multiband = 2. An MPRAGE was acquired for anatomical reference (1-mm isotropic resolution, FOV = 256 × 256 mm2, 192 slices, TI/TR = 857/2300 ms). The total scan time was 45 minutes.

2.5.2. Data processing

Multi-shell multi-diffusion time data were preprocessed jointly. Pre-processing steps included MP-PCA magnitude denoising (Veraart et al., 2016), Gibbs ringing correction (Kellner et al., 2016), and distortion and eddy current correction (J. L. Andersson & Sotiropoulos, 2016). The cortical ribbon was segmented on the MPRAGE image using FastSurfer (Henschel et al., 2020) and projected onto the native diffusion image space using linear registration (Avants et al., 2009). Data were powder averaged using the arithmetic mean and normalized by the mean b = 0 ms/µm2 values before being fed to the trained µGUIDE for model parameters’ inference.

3. Results

3.1. Simulations

Figures 2 and 3 present simulated signals of representative gray matter tissue configurations (Jelescu et al., 2022; Olesen et al., 2022) under both acquisition protocols, in a noise-free scenario. It is worth noting that the b-values used in the Connectom protocol are not strong enough to reach the stick power law. Additionally, at fixed b-value, the dMRI signal—for the set of model parameters investigated—systematically decreases with diffusion time, reflecting the dominance on time dependence of exchange dynamics over structural restrictions, as enforced in both models (Olesen et al., 2022). Posterior distributions obtained using µGUIDE demonstrate accurate and consistent parameter recovery across both protocols and models, with noticeably improved accuracy (i.e., smaller bias in the MAP) and precision (i.e., narrower posterior distributions) when using the extensive ex vivo acquisition protocol. The pairplots further illustrate the relationships between parameters, showing weak correlations and compact, unimodal posterior distributions, consistent with good parameter recovery in this noise-free setting.

Fig. 2.

Two panels, A and B, each show diffusion signal decay curves plotted against b in milliseconds per micrometer squared, with legends for Extended and Connectom acquisitions at diffusion times Δ of 7.5, 11.0, 16.0, 20, 29, 39, and 49 milliseconds; inset graphs plot signal versus 1 over square root of Δ with shaded confidence bands showing a rising trend. Below each are corner plots of posterior distributions for parameters t_ex, D_i, D_e, and f_h, comparing Extended, Connectom, and ground truth, with diagonal histograms and off-diagonal joint density scatter.

Simulated signals of the NEXI model, without noise, obtained from exemplar gray matter tissues using both acquisition protocols, and posterior distributions obtained with µGUIDE. For each subplot, upper rows: Left plots show the signal with b-values inferior to 10 ms/µm2 as a function of b, and right subplot shows the signal for b-values superior to 5 ms/µm2 as a function of b−1/2 . Dots represent the simulated data, solid lines show signals generated from the MAP estimates, and shaded areas encompass all signals corresponding to parameter combinations sampled from the posterior distributions, illustrating their uncertainty. Bottom rows: Marginal posterior distributions of each parameter obtained with µGUIDE in the diagonal, and pairplots in the lower diagonal. Vertical black dashed lines and black crosses correspond to the ground truth values. Model parameters used to generate the signals are the following: (A) tex = 43 ms, Dn∥=2.55 µm2/ms, De =0.74 µm2/ms, fn=0.29 (Jelescu et al., 2022); (B) tex =8.15 ms, Dn∥=1.45 µm2/ms, De =0.55 µm2/ms, fn =0.525 (Olesen et al., 2022).

Fig. 3.

Two panels, A and B, each show signal decay plots with corresponding corner plots of parameter posterior distributions. Top plots show normalized signal versus b (ms per square micrometer) as decaying curves, with a companion axis versus 1 over the square root of b, comparing Extended and Connectom methods at diffusion times Δ from 7.5 to 49 ms. Corner plots below display PDFs and pairwise distributions for parameters including t_ex, D_i, D_e, f_n, r_s, and f_s, with ground truth marked; panel A shows tighter estimates while panel B shows broader spread.

Simulated signals of the SANDIX model, without noise, obtained from exemplar gray matter tissues using both acquisition protocols, and posterior distributions obtained with µGUIDE. For each subplot, upper rows: Left plots show the signal with b-values inferior to 10 ms/µm2 as a function of b, and right subplot shows the signal for b-values superior to 5 ms/µm2 as a function of b−1/2 . Dots represent the simulated data, solid lines show signals generated from the MAP estimates, and shaded areas encompass all signals corresponding to parameter combinations sampled from the posterior distributions, illustrating their uncertainty. Bottom rows: Marginal posterior distributions of each parameter obtained with µGUIDE in the diagonal, and pairplots in the lower diagonal. Vertical black dashed lines and black crosses correspond to the ground truth values. Model parameters used to generate the signals are the following: (A) tex = 43 ms, Dn∥=2.55 µm2/ms, De =0.74 µm2/ms, fn =0.29 , rs = 15 µm, and fs =0.2 (Jelescu et al., 2022); (B) tex =4.95 ms, Dn∥=1.0 µm2/ms, De =0.9 µm2/ms, fn =0.54 , rs =11.4 µm, and fs =0.13 (Olesen et al., 2022).

The difference in uncertainty observed for the NEXI model between scenarios A and B in Figure 2 can be explained by the underlying parameter regimes. In scenario A, the intra- and extra-neurite diffusivities are well separated (Dn∥=2.55 µm2/ms and De =0.74 µm2/ms), and the exchange time is relatively long (tex = 43), leading to more distinct signal contributions from each compartment and facilitating the estimation of fn. In contrast, in scenario B, the diffusivities are closer (Dn∥=1.45 µm2/ms and De =0.55 µm2/ms), and the exchange time is much shorter (tex =8.15 ms). This results in stronger mixing between compartments with similar diffusion properties, making it more difficult to disentangle their respective contributions and leading to increased uncertainty in fn. Similar trends are observed for the SANDIX model (Fig. 3). In addition, the longer diffusion times used in the Connectom protocol reduce sensitivity to fast exchange processes, which may further contribute to the increased uncertainty observed in this regime.

Figures 4 and 5 expand upon the results shown in Figures 2 and 3 by evaluating 1000 test simulations. These figures present µGUIDE fitting results for the NEXI and SANDIX models across both acquisition protocols, under both noise-free (A & B) and noisy (C & D) conditions. The extensive ex vivo protocol enables highly accurate and precise parameter estimation in the absence of noise, with minimal degeneracies (indicated by red dots) and low uncertainty (subplots A). However, its performance significantly degrades in the presence of noise, as the signal at high b-values is mostly lost (subplots C). In contrast, the Connectom protocol, relying on lower b-values, is less affected by low SNR, but suffers from reduced accuracy and increased variance even in noise-free settings (subplots B and D). Across simulations, we observe that low-uncertainty estimates tend to coincide with low-bias estimates (falling near the diagonal), whereas biased estimates (away from the diagonal) are typically associated with higher uncertainty. This suggests that wider posterior distributions may still encompass the ground truth values, even when MAP estimates are biased. Additionally, the presence of noise appears to reduce the number of detected degeneracies (Table 1). This can be explained by the increased uncertainty caused by noise, which widens the posterior distributions. In this scenario, multiple distinct peaks can blend into a single broader peak, causing degeneracies to be hidden.

Fig. 4.

NEXI parameter estimation scatter plots comparing MAP versus ground truth for t_ex, D_i, D_e, and f_n, arranged in four panels: A) Extended protocol noise-free, B) Connectom protocol noise-free, C) Extended noisy SNR about 36, D) Connectom noisy. Points highlighted by uncertainty percent, with uncertainty histograms below each. Noise-free panels show tight diagonal fits; noisy panels show more scatter, especially for t_ex.

Fitting results for the NEXI model using µGUIDE on 1000 test simulations. Results are shown for the extensive ex vivo acquisition protocol (A & C), and the NEXI 3T Connectom protocol (B & D). In each subplot, the top row displays the MAP estimates of the model parameters plotted against their ground truth values, color coded by their uncertainty values. Red dots indicate cases where the posterior distribution was identified as degenerate. The bottom row shows the distribution of uncertainty values across all test simulations.

Fig. 5.

SANDIX method comparison showing scatter plots of MAP versus ground truth for parameters f_ex, D_e superscript I, D_e, f_n, f_s across Extended and Connectom protocols, with points highlighted by uncertainty percentage and histogram distributions of uncertainty below; top rows show noise-free tightly correlated diagonals while bottom rows show noisy SNR near 36 with greater scatter.

Fitting results for the SANDIX model using µGUIDE on 1000 test simulations. Results are shown for the extensive ex vivo acquisition protocol (A & C), and the NEXI 3T Connectom protocol (B & D). In each subplot, the top row displays the MAP estimates of the model parameters plotted against their ground truth values, color coded by their uncertainty values. Red dots indicate cases where the posterior distribution was identified as degenerate. The bottom row shows the distribution of uncertainty values across all test simulations.

Table 1.

Percentage of degenerate voxels for the NEXI and SANDIX models, in noise-free and noisy (SNR∼36) conditions, for both the extensive and Connectom protocols.

tex Dn∥ De fn rs fs
NEXI Extensive protocol Noise-free 1.2 1.3 2.0 0.1
Noisy 3.1 1.0 0.1 0.0
Connectom protocol Noise-free 2.5 4.2 5.1 0.5
Noisy 2.6 1.2 0.5 0.2
SANDIX Extensive protocol Noise-free 0.2 3.4 2.1 0.4 0.2 0.0
Noisy 0.0 1.2 0.4 0.2 0.2 0.2
Connectom protocol Noise-free 0.4 5.6 3.2 0.1 0.3 0.0
Noisy 1.3 0.0 0.0 0.0 0.2 0.1

Similar trends are obtained using a non-linear least squares (NLLS) fitting approach with Rician mean correction, as implemented in Uhl et al. (2024) (see Supplementary Figs. S1 and S2). However, some NLLS estimates reach the imposed parameter bounds (e.g., for the NEXI model, Dn, De at their upper limits and tex, fn near zero), indicating that the optimizer converged to boundary solutions of the parameter space rather than physiologically meaningful values. Additionally, even in the absence of noise, NLLS estimates for several SANDIX parameters exhibit substantial dispersion, reflecting the presence of multiple parameter combinations yielding similar signals and an optimization landscape likely containing multiple local minima. As a result, the optimizer may converge to different solutions that fit the data equally well. µGUIDE offers several advantages over NLLS, including the detection of degeneracies, the estimation of parameter uncertainty, and computational time between 5 and 12 times faster on simulations (see Supplementary Table S1).

As shown in Figure 4D, estimating the exchange time tex using the NEXI model under realistic conditions, that is, using the Connectom acquisition protocol with Rician-distributed noise, is challenging. This is especially true for longer exchange times that exceed the protocol’s range of sampled diffusion times (Δ∈[20;49] ms and δ = 9 ms), resulting in biased and uncertain estimates. Nonetheless, the NEXI model reliably estimates other key parameters such as De and fn. When applying the SANDIX model to simulations generated using the Connectom protocol and realistic noise levels, Figure 5D demonstrates that the exchange time estimates are mostly unreliable. However, as with NEXI, the model provided robust estimates of De and fn. In addition, we note that for soma radii larger than 17 µm, the uncertainty in the estimates increases, which is consistent with previous findings (Dong et al., 2025).

3.2. In vivo dMRI data

Figures 6 and 7 show the parameter estimates obtained using µGUIDE with the NEXI and SANDIX models on in vivo data from a participant scanned with the 3T Connectom protocol. Each figure displays both the MAP estimates and associated uncertainty measures for each parameter. Red dots indicate voxels presenting a degeneracy in their posterior distributions. As seen in the simulations, both models yield high uncertainty for the exchange time tex, indicating limited confidence in its estimation with the current protocol. In contrast, estimates of De and fn exhibit low uncertainty, consistent with the model’s robust performance for these parameters in the simulated data.

Fig. 6.

NEXI brain map figure with two rows of coronal brain slices across four columns of parameters: t_ex in milliseconds, D_i in square micrometers per millisecond, D_e in square micrometers per millisecond, and f_n in arbitrary units. Top row shows maximum-a-posteriori estimates, bottom row shows uncertainty in percent, each with coded scales; a dot legend indicates degeneracy.

Fitting results of the NEXI model on in vivo data from one participant scanned using the 3T Connectom protocol, estimated using µGUIDE. For each model parameter, the MAP estimate and associated uncertainty are shown for a single coronal slice of the brain. Voxels exhibiting degenerate posterior distributions are marked with red dots.

Fig. 7.

SANDIX brain mapping showing two rows of coronal brain slice images with coded values. Top row labeled Maximum-a-posteriori shows parameters t_ex ms, D_e^0 µm²/ms, D_a µm²/ms, f_e a.u., r_s µm, and f_s a.u. Bottom row shows the uncertainty percent for the same parameters. Each slice has a vertical scale bar.

Fitting results of the SANDIX model on in vivo data from one participant scanned using the 3T Connectom protocol, estimated using µGUIDE. For each model parameter, the MAP estimate and associated uncertainty are shown across a brain slice. Voxels exhibiting degenerate posterior distributions are marked with red dots.

Figure 8 presents a comparison of NEXI and SANDIX parameter estimates across the cortical ribbons of all participants, obtained using µGUIDE and the NLLS method, as implemented in Uhl et al. (2024). For µGUIDE, estimates are thresholded by their posterior uncertainty: we report distributions retaining only the voxels whose uncertainty is inferior to 50%, 30%, and 10%. Voxels with the lowest uncertainty are considered the most reliable. In contrast, no quality-based filtering is applied to the NLLS results. Notably, NLLS estimates frequently hit the boundaries of the predefined parameter ranges, indicating potential instability.

Fig. 8.

A grid of histograms comparing NEXI and SANDIX diffusion model parameters, with rows for muGUIDE MAPs and NLLS estimates. Columns show distributions of t_ex in milliseconds, D, D_e in micrometers squared per millisecond, f, r_s in micrometers, and f_s. MAP histograms are coded by uncertainty thresholds below 50, 30, and 10 percent, showing peaked distributions.

Comparison of parameter estimates across cortical ribbons from all participants using µGUIDE and an NLLS method. µGUIDE estimates are thresholded based on posterior distribution uncertainty, with distributions shown for voxels with uncertainty below 50%, 30%, and 10%. In some cases, thresholding does not alter the distribution, resulting in overlapping curves that may not be visually distinguishable.

Table 2 reports the proportion of voxels exhibiting posterior distribution degeneracies across all six acquisitions for both models. Table 3 summarizes the percentage of voxels with uncertainty below 50%, 30%, and 10%, respectively, again for both models.

Table 2.

Percentage of degenerate voxels across cortical ribbons from all data acquisitions.

tex Dn∥ De fn rs fs
NEXI 1.76 0.52 4.23 0.11
SANDIX 0.47 0.02 0.27 0.01 0.14 0.25

Table 3.

Percentage of voxels across cortical ribbons from all data acquisitions whose uncertainty is inferior to 50%, 30%, 20%, and 10%.

tex Dn∥ De fn rs fs
NEXI Uncertainty < 50% 99.98 100 100 100
Uncertainty < 30% 82.37 99.95 100 99.78
Uncertainty < 20% 51.18 85.44 99.87 99.29
Uncertainty < 10 40.85 8.71 91.72 51.23
SANDIX Uncertainty < 50% 100 100 100 100 100 100
Uncertainty < 30% 62.90 99.98 99.99 100 83.12 99.96
Uncertainty < 20% 38.5 52.12 99.15 99.79 31.51 82.02
Uncertainty < 10% 26.73 11.80 85.36 69.61 3.45 15.39

Estimates of the exchange time tex display a bimodal distribution, with peaks at both low and high values (Fig. 8). The high tex peak may reflect partial volume effects from WM, where myelin reduces the axons permeability (Dong et al., 2025). As expected from simulations, this peak disappears when filtering out voxels with high uncertainty. Only 40.85% (NEXI) and 26.73% (SANDIX) of voxels yield reliable tex estimates with uncertainty below 10% (corresponding to an interquartile range of ∼15 ms) (Table 3). With this uncertainty threshold, the mean MAP estimates are 5.51 ms (NEXI) and 7.24 ms (SANDIX), which reflect rapid water exchange across permeable neurite membranes.

For intra-neurite diffusivity Dn∥, µGUIDE and NLLS produce noticeably different distributions (Fig. 8). Only ∼10% of the Dn∥ estimates are deemed reliable with µGUIDE, with a mean MAP of 2.85 µm2/ms for NEXI and 2.88 µm2/ms for SANDIX (Table 3).

By contrast, estimates of extra-neurite diffusivity De and neurite signal fraction fn show more consistency for most voxels across both methods and models, although De distributions with NLLS present longer tail for SANDIX, and higher fn estimates for NEXI (Fig. 8). These parameters also exhibit the lowest uncertainty in the µGUIDE estimates, in agreement with simulation findings (Figs. 4 & 5).

Soma radii estimates (rs) show substantial differences between µGUIDE and NLLS. As predicted by simulations, estimates of large soma radii tend to have higher uncertainty (Fig. 5), causing the high-radius peak to disappear when filtering for voxels with less than 10% uncertainty (equivalent to a ∼3 µm interquartile range). Only 3.45% of voxels yield reliable rs estimates at this threshold (Table 3), clustering around one main peak at ∼10 µm, and a smaller one ∼5 µm. Estimates of the soma signal fraction fs are also uncertain, with only 15.39% of voxels passing the 10% uncertainty threshold. For those few voxels, the mean estimate of fs is 0.05.

Scan–rescan analyses for two participants show that the proportions of degenerate voxels (Table 4) and the percentages of voxels with uncertainty below 50%, 30%, and 10% (Table 5) are highly consistent across sessions for both models. This reproducibility suggests that the degeneracy detection and uncertainty quantification provided by µGUIDE are robust and reproducible.

Table 4.

Percentage of degenerate voxels across cortical ribbons from the scan–rescan acquisitions for both subjects (S1 and S2).

tex Dn∥ De fn rs fs
S1 S2 S1 S2 S1 S2 S1 S2 S1 S2 S1 S2
NEXI 1.77 1.77 0.42 0.54 4.20 4.51 0.09 0.13
SANDIX 0.42 0.52 0.03 0.02 0.23 0.26 0.01 0.01 0.14 0.13 0.20 0.21

Table 5.

Percentage of voxels across cortical ribbons from the scan–rescan acquisitions for both subjects (S1 and S2) whose uncertainty is inferior to 50%, 30%, and 10%.

tex Dn∥ De fn rs fs
S1 S2 S1 S2 S1 S2 S1 S2 S1 S2 S1 S2
NEXI Uncertainty < 50% 99.99 99.99 100 100 100 100 100 100
Uncertainty < 30% 82.32 82.49 99.96 99.95 99.99 100 99.82 99.79
Uncertainty < 10% 42.16 40.58 7.95 9.22 91.77 91.39 49.78 51.51
SANDIX Uncertainty < 50% 100 100 100 100 100 100 100 100 100 100 100 100
Uncertainty < 30% 64.18 62.92 99.98 99.98 99.99 99.99 99.99 100 83.39 83.27 99.97 99.96
Uncertainty < 10% 27.87 27.15 11.22 11.57 85.36 85.81 68.42 69.82 3.21 3.29 14.41 16.08

Figure 9 replicates the comparison from Figure 8 using scan–rescan data from two participants (see Supplementary Fig. S3 for results on the second participant scanned twice). For µGUIDE, we show both the full distribution of MAP estimates and the subset of MAPs with uncertainty below 10%. Overall, both µGUIDE and NLLS yield similar parameter distributions and appear robust across sessions. The small differences observed between scan and rescan are likely attributable to noise effects. In particular, the largest variability is observed for Dn∥, which is consistent with this parameter showing higher uncertainty in both models.

Fig. 9.

A grid of histograms comparing NEXI and SANDIX diffusion models, each with pGUIDE and NLLS rows, plotting distributions of parameters t_ex (ms), D_i and D_e (micrometers squared per ms), f_n, r_s, and f_s. Bars represent Subject 1 Sessions 1 and 2 MAPs and NLLS fits, with lighter shades marking MAPs with uncertainty less than 10 percent. Distributions show peaked, skewed shapes with overlapping session curves.

Comparison of parameter estimates across cortical ribbon from one participant on two sessions using µGUIDE and an NLLS method. µGUIDE estimates are thresholded based on posterior distribution uncertainty, with distributions shown for voxels with uncertainty below 10%.

4. Discussion

In this work, we investigated the reliability of parameter estimates in GM biophysical models. Specifically, we examined the NEXI and SANDIX models, which have been proposed to account for exchange between neurites and the extra-cellular space. While these models hold promise for advancing our understanding of GM microstructure, their solution landscapes and the reliability of their parameter estimates have not been thoroughly assessed. Our results reveal that certain parameters, including exchange time, intra-neurite diffusivity, and soma radius and fraction, are challenging to estimate accurately. We show that the estimated values can be unreliable, either because multiple parameter combinations can explain equally well the observed data (i.e., degeneracies), or because the confidence in the estimates is inherently low (i.e., high uncertainty). These issues have significant implications for the interpretation of results based on these models. Thus, this study emphasizes the importance of quantifying the reliability of model parameter estimates, using Bayesian inference. We suggest highlighting degeneracies and uncertainties, for example, as provided by µGUIDE, to complement measures of MAP to refine and improve the interpretability of the biophysical model parameter estimates, ultimately leading to a more reliable understanding of the biological changes occurring in pathology and disease.

4.1. Choice of acquisition protocol and impact of noise

Our results demonstrate that extensively sampling the acquisition space across a broad range of b-values and diffusion times substantially reduces parameter degeneracies and leads to lower uncertainties. Simulations (Figs. 4 & 5) show that, in a noise-free scenario, the extensive protocol results in a low proportion of degenerate posterior distributions (1.2% for NEXI and 0.2% for SANDIX for tex) and yields estimates with low uncertainty (inferior to 20% for NEXI and 42% for SANDIX, for all parameters). In contrast, the reduced Connectom protocol, while still yielding reasonably accurate estimates, exhibits a higher incidence of degeneracies and greater uncertainty. Specifically, degeneracies are two times more likely to occur using the Connectom protocol compared with the extensive one for the exchange time with both models, and uncertainties are almost three times higher for tex with the NEXI model. Interestingly, we also observe that NEXI exhibits a higher proportion of degeneracies than SANDIX, both in simulations and in in vivo data (Tables 1 & 2). Importantly, this difference should not be interpreted as evidence that SANDIX is intrinsically more accurate. Rather, degeneracies reflect the ability of different parameter combinations to produce similar signals given both the model structure and the acquisition protocol. The simpler two-compartment structure of NEXI may lead to stronger parameter coupling given those acquisition protocols, where different combinations of exchange time and diffusivities produce similar signals, resulting in increased degeneracy. In contrast, the additional compartment in SANDIX can help capture specific signal features and partially reduce degeneracies in certain regimes. However, this increased model complexity does not fully resolve parameter degeneracies and instead leads to high uncertainty frequent degeneracies in the additional parameters related to the soma. This suggests that, in practice, the added flexibility of SANDIX does not necessarily translate into more reliable microstructural information in this setting. Instead, it emphasizes the importance of matching model complexity to the sensitivity of the acquisition protocol. Under limited acquisition conditions, simpler models such as NEXI may provide more robust and interpretable estimates, whereas more complex models require richer sampling strategies to ensure reliable parameter estimates.

Our results highlight the value of richer sampling for improving the robustness and reliability of parameter estimation in biophysical modeling. However, translating such rich sampling schemes to human in vivo studies remains challenging. The Connectom protocol already approaches the upper limit of acceptable scan duration for human participants (45 minutes), and the preclinical protocol is far too long (100 h and 14 minutes) to be feasible in this context. In clinical settings, where substantially shorter acquisition times are required, this challenge becomes even more pronounced. Reducing acquisition time would likely further degrade parameter estimation, increasing both uncertainty and degeneracy, particularly for parameters that already exhibit high uncertainty (e.g., exchange time and soma-related parameters). In addition to scan time constraints, hardware limitations, and particularly the achievable gradient strengths, restrict the accessible range of b-values and diffusion times, further limiting sensitivity to some model parameters. Importantly, shortening a protocol is not a trivial subsampling problem, as it requires re-optimizing the acquisition to preserve sensitivity to the parameters of interest. This underscores the need for dedicated protocol optimization strategies tailored to clinical constraints (e.g. Alexander (2008), Planchuelo-Gómez et al. (2024), Popolo et al. (2025), and Uhl, Pavan, Gerold, et al. (2025)), potentially guided by uncertainty and degeneracy measures (Popolo et al., 2025).

We further show that the presence of realistic (Rician-distributed) noise in the observed signals increases both the bias and uncertainty of parameter estimates, which in turn impact results interpretation. Estimates of large exchange times are particularly impacted, suggesting a reduced sensitivity to intermediate-to-long exchange times beyond the range of sampled diffusion times of the acquisition protocol. This reflects the “filtering” effect of the diffusion-time range, where only exchange processes with characteristic times comparable with the sampled diffusion times can be reliably estimated (Dong et al., 2025; Jelescu et al., 2022). When diffusion times are too short, slow exchange cannot be captured, causing exchange-time estimates to plateau once the ground truth exceeds the accessible diffusion-time window. Nevertheless, if biologically plausible exchange times in gray matter are on the order of a few tens of milliseconds, reduced sensitivity to much longer values may be less problematic in practice. While Rician noise was used to mimic realistic magnitude dMRI acquisitions, additional simulations using Gaussian noise with matched SNR (see Supplementary Fig. S4) yielded very similar uncertainty and degeneracy patterns, with only slightly reduced bias in the estimated parameters, as expected given the absence of the Rician noise floor at low signal levels. This indicates that the main effects observed here are primarily driven by the signal-to-noise ratio and acquisition design rather than the specific noise distribution.

Overall, these results highlight the critical influence of acquisition design, particularly b-value and diffusion time selection, as well as noise levels, on the accuracy and precision of biophysical parameter estimates. They underscore the need for designing acquisition protocols specifically optimized to enhance the reliability of parameter estimation in gray matter modeling. Future work should focus on refining these protocols to balance scan time, signal quality, and parameter sensitivity, using optimization methods such as Alexander (2008), Planchuelo-Gómez et al. (2024), Popolo et al. (2025), and Uhl, Pavan, Gerold, et al. (2025). Incorporating uncertainty and degeneracy measures into this optimization process could further guide the selection of acquisition parameters to maximize the robustness of parameter estimates.

4.2. Importance of characterizing degeneracy and uncertainty

Accurate interpretation of model-derived parameters is essential, as misinterpretations can lead to false conclusions. In this context, degeneracies and uncertainties as obtained from posterior distributions are useful complementary information that guide the interpretation of model estimates. Voxels with low posterior uncertainty indicate higher confidence in the corresponding parameter estimates, enabling the identification of robust trends and a more reliable understanding of the underlying tissue microstructure.

Although µGUIDE and NLLS fitting yield similar distributions for certain parameters such as De and fn, notable differences emerge for other parameters (Fig. 8). In particular, µGUIDE produces lower MAP estimates of exchange time than previously reported using NLLS in in vivo studies: 5.51 ms with NEXI and 7.24 ms with SANDIX (mean MAP estimates of voxels with non-degenerate posterior distributions with uncertainty inferior to 10%), compared with estimates between 10 and 50 ms typically reported in the literature (Dong et al., 2025; Jelescu et al., 2022; Uhl et al., 2024; Veraart et al., 2020). The high peak observed around ∼125 ms in µGUIDE results may be driven by partial volume effects with white matter (and/or CSF), as previously suggested (Dong et al., 2025).

The exchange-time estimates obtained in this study depend strongly on the uncertainty threshold applied. While estimates obtained with relaxed thresholds are consistent with previously reported values in the human cortex (≈ 10–80 ms), more conservative thresholds lead to substantially lower mean values. For example, for the NEXI model, the mean MAP decreases from 46.26 ms (<50%) to 43.25 ms (<30%), 24.20 ms (<20%), and 5.51 ms (<10%). A similar trend is observed for SANDIX, with mean values decreasing from 45.58 ms (<50%) to 33.39 ms (<30%), 8.80 ms (<20%), and 7.24 ms (<10%). This reflects a selection effect, whereby only voxels with deemed reliable estimates are retained as the threshold becomes smaller. This filtering excludes estimates with longer exchange times, which are more difficult to estimate reliably, thereby shifting the mean toward lower values. This effect is also closely related to the diffusion-time range of the acquisition protocol, which acts as a filter on the exchange times that can be reliably probed. In particular, the diffusion times used in this study (∼20–50 ms) limit sensitivity to longer exchange processes, resulting in higher uncertainty for large exchange times. Consequently, these values are more likely to be excluded by uncertainty-based filtering, leading to an apparent bias toward shorter exchange times. In comparison, NLLS estimates (54.07 ms for NEXI and 30.20 ms for SANDIX) fall within a similar range but do not account for uncertainty. These results highlight the importance of jointly considering acquisition design and uncertainty when interpreting exchange-time estimates. By leveraging degeneracy detection and uncertainty quantification from µGUIDE, unreliable voxels can be filtered out, isolating only the most trustworthy estimates. Consequently, the parameter distributions obtained via µGUIDE are more robust and interpretable than those derived from NLLS alone, reinforcing the importance of accounting for uncertainty and degeneracy in biophysical modeling.

4.3. Robustness and reproducibility

Our scan–rescan analysis (Fig. 9) provides further insight into the robustness of parameter estimation using both µGUIDE and NLLS. Overall, the distributions of estimates were consistent across the two sessions for both methods, indicating good reproducibility. For µGUIDE, the agreement between sessions improved when restricting the analysis to voxels with low posterior uncertainty (<10%), highlighting the utility of uncertainty-based filtering to improve reliability. The differences observed between scan and rescan can largely be attributed to noise variability, with the intracellular diffusivity (Dn∥) showing the largest fluctuations, which is consistent with its higher uncertainty in both NEXI and SANDIX. These results suggest that while both µGUIDE and NLLS yield stable estimates at the subject level, incorporating uncertainty measures, as in µGUIDE, can improve the robustness of reproducibility assessments and help identify parameters more sensitive to noise.

4.4. Limitations

The current study has several limitations. First, we evaluated only two acquisition protocols: an extensive protocol developed for ex vivo acquisitions, and a protocol feasible on Connectom scanners. Neither reflects the typical scan parameters used in most clinical 3T MRI systems, which are constrained by lower gradient amplitudes and longer echo times, resulting in reduced achievable b-values and lower SNR per unit time (Uhl, Pavan, Feiweier, et al., 2025). To ensure a fair comparison between protocols, we added Rician noise at an identical level to both sets of simulated signals, even though this SNR level is unrealistically low for ex vivo acquisitions. This choice was made to isolate and study the impact of noise on model fitting performance, despite the fact that the extensive protocol is impractical in vivo due to its duration. Additionally, partial volume effects could have affected parameter estimates in the GM ribbon due to the limited resolution of the acquired images. Future studies could mitigate these effects by leveraging emerging acquisition techniques, such as the DW-GRASE sequence with 3D navigator (Li et al., 2025), which offer higher resolution for time-dependent dMRI.

Second, we focused exclusively on two biophysical models that incorporate exchange times, that is, NEXI and SANDIX. Other biophysical models also include exchange time, such as SMEX (see Section 2.1.2), or eSANDIX (Olesen et al., 2022), which also integrates impermeable neurites. In this study, our goal was not to determine which model best describes gray matter microstructure, but rather to demonstrate that parameter estimates from such models can be prone to degeneracies and uncertainty. This highlights a key limitation in current fitting approaches, where confidence in parameter estimates is not quantified and accounted for when interpreting the results, and degeneracies are ignored (Jallais & Palombo, 2024).

Third, this study focused exclusively on PGSE acquisitions and did not consider alternative diffusion encoding strategies that can help alleviate parameter degeneracies. Advanced diffusion waveforms can provide increased sensitivity to specific microstructural features and help disentangle the effects of restriction and exchange (Chakwizira, Szczepankiewicz, & Nilsson, 2025; Chakwizira, Westin, et al., 2023; Chakwizira, Zhu, et al., 2023; Lasič et al., 2024). Moreover, combining multiple complementary acquisition schemes, such as single and double diffusion encoding as proposed in Jallais et al. (2025), can further improve parameter estimation, enhance the robustness of the fitting, and reduce degeneracies. Future work should explore these strategies to effectively mitigate degeneracies.

5. Conclusion

In this study, we investigated the reliability of parameter estimates from biophysical models of gray matter that incorporate water exchange, with a focus on NEXI and SANDIX. Through simulations and in vivo data, we demonstrated that key parameters, such as exchange time, soma radius, and soma fraction, are challenging to estimate reliably, due to intrinsic model degeneracies, sensitivity to acquisition settings, and noise. While extensive protocols can substantially reduce uncertainty and the presence of degeneracies, they remain impractical for in vivo acquisitions. In contrast, protocols feasible for in vivo human applications, such as the NEXI 3T Connectom protocol, yield more robust fits in the presence of noise, but show reduced accuracy and increased parameter uncertainty. We showed that µGUIDE provides more robust and interpretable estimates than traditional NLLS fitting by identifying degenerate solutions and leveraging uncertainty measures derived from the posterior distributions. These findings highlight the importance of accounting for the reliability of individual estimates in biophysical modeling, particularly for drawing meaningful biological conclusions and comparing clinical populations. Ultimately, our work advocates for uncertainty-aware inference as a critical step toward more reliable and biologically meaningful diffusion MRI analysis.

Supplementary Material

Supplementary Material
IMAG.a.1317_supp.pdf (10.4MB, pdf)

Data and Code Availability

The code used in this study is available at https://github.com/mjallais/NEXI_SANDIX_uGUIDE. No new data was created during this study. The data analyzed are from a previously published study and are available from the original data custodians upon reasonable request, subject to a data sharing agreement and ethics approval, as described in https://doi.org/10.1162/imag_a_00104.

Author Contributions

Conceptualization: M.J., Q.U., I.J., M.P.; data curation: M.J., Q.U., T.P., M.M.; formal analysis: M.J., Q.U.; funding acquisition: D.K.J., I.J., M.P.; investigation: M.M., I.J., M.P.; methodology: M.J., Q.U., I.J., M.P.; supervision: I.J., M.P.; visualization: M.J., Q.U.; writing—original draft: M.J.; writing—review and editing: M.J., Q.U., M.M., D.K.J., I.J., M.P.

Funding

M.J. and M.P. are supported by UKRI Future Leaders Fellowship (MR/T020296/2 and 1073). Q.U., T.P. and I.J. are supported by an SNSF Eccellenza Fellowship (194260). This research was funded in whole, or in part, by a Wellcome Trust Strategic Award (104943/Z/14/Z). D.K.J. is also supported by Wellcome Discovery Awards (227882/Z/23/Z and 317797/Z/24/Z). For the purpose of open access, the author has applied a CC BY public copyright license to any Author Accepted Manuscript version arising from this submission.

Declaration of Competing Interest

The authors declare no competing interest.

Supplementary Materials

Supplementary material for this article is available with the online version here: https://doi.org/10.1162/IMAG.a.1317#supplementary-data

References

  1. Abad, N., Bhushan, C., Ajala, A., Sprenger, T., Marinelli, L., Morris, H. D., DeMarco, J. K., Hood, M., Kohls, G., Ho, V. B., & Foo, T. K. (2025). Feasibility of brain intra-axonal microstructure imaging with ultrahigh B-encoding using MAGNUS ultra-high-performance gradients. Imaging Neuroscience, 3, imag.a.68. 10.1162/imag.a.68 [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. Afzali, M., Nilsson, M., Palombo, M., & Jones, D. K. (2021). SPHERIOUSLY? The challenges of estimating sphere radius non-invasively in the human brain from diffusion MRI. NeuroImage, 237, 118183. 10.1016/j.neuroimage.2021.118183 [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Alexander, D. C. (2008). A general framework for experiment design in diffusion MRI and its application in measuring direct tissue-microstructure features. Magnetic Resonance in Medicine, 60(2), 439–448. 10.1002/mrm.21646 [DOI] [PubMed] [Google Scholar]
  4. Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2017). Imaging brain microstructure with diffusion MRI: Practicality and applications. NMR in Biomedicine, 32(4), 3841. 10.1002/nbm.3841 [DOI] [PubMed] [Google Scholar]
  5. Andersson, J. L., & Sotiropoulos, S. N. (2016). An integrated approach to correction for off-resonance effects and subject movement in diffusion MR imaging. NeuroImage, 125, 1063–1078. 10.1016/j.neuroimage.2015.10.019 [DOI] [PMC free article] [PubMed] [Google Scholar]
  6. Andersson, M., Kjer, H. M., Rafael-Patino, J., Pacureanu, A., Pakkenberg, B., Thiran, J.-P., Ptito, M., Bech, M., Bjorholm Dahl, A., Andersen Dahl, V., & Dyrby, T. B. (2020). Axon morphology is modulated by the local environment and impacts the noninvasive investigation of its structure–function relationship. Proceedings of the National Academy of Sciences, 117(52), 33649–33659. 10.1073/pnas.2012533117 [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Avants, B. B., Tustison, N., Song, G., Duda, J. T., & Johnson, H. J. (2009). Advanced normalization tools (ANTS). Insight J, 2(365), 1–35. 10.54294/uvnhin [DOI] [Google Scholar]
  8. Bai, R., Springer Jr., C. S., Plenz, D., & Basser, P. J. (2018). Fast, Na+/K+ pump driven, steady-state transcytolemmal water exchange in neuronal tissue: A study of rat brain cortical cultures. Magnetic Resonance in Medicine, 79(6), 3207–3217. 10.1002/mrm.26980 [DOI] [PubMed] [Google Scholar]
  9. Balinov, B., Jönsson , Linse, P., & Söderman, O. (1993). The NMR self-diffusion method applied to restricted diffusion. Simulation of echo attenuation form molecules in spheres and between planes. Journal of Magnetic Resonance, 104(1), 17–25. 10.1006/jmra.1993.1184 [DOI] [Google Scholar]
  10. Chakwizira, A., Şimşek, K., Szczepankiewicz, F., Palombo, M., & Nilsson, M. (2025). The role of dendritic spines in water exchange measurements with diffusion MRI: Double diffusion encoding and free-waveform MRI. NMR in Biomedicine, 39(7), e70315. 10.1002/nbm.70315 [DOI] [PubMed] [Google Scholar]
  11. Chakwizira, A., Szczepankiewicz, F., & Nilsson, M. (2025). Diffusion MRI with double diffusion encoding and variable mixing times disentangles water exchange from transient kurtosis. Scientific Reports, 15(1), 8747. 10.1038/s41598-025-93084-4 [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Chakwizira, A., Westin, C.-F., Brabec, J., Lasič, S., Knutsson, L., Szczepankiewicz, F., & Nilsson, M. (2023). Diffusion MRI with pulsed and free gradient waveforms: Effects of restricted diffusion and exchange. NMR in Biomedicine, 36(1), e4827. 10.1002/nbm.4827 [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. Chakwizira, A., Zhu, A., Foo, T., Westin, C.-F., Szczepankiewicz, F., & Nilsson, M. (2023). Diffusion MRI with free gradient waveforms on a high-performance gradient system: Probing restriction and exchange in the human brain. NeuroImage, 283, 120409. 10.1016/j.neuroimage.2023.120409 [DOI] [PubMed] [Google Scholar]
  14. Coelho, S., Pozo, J. M., Jespersen, S. N., Jones, D. K., & Frangi, A. F. (2019). Resolving degeneracy in diffusion MRI biophysical model parameter estimation using double diffusion encoding. Magnetic Resonance in Medicine, 82(1), 395–410. 10.1002/mrm.27714 [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Cranmer, K., Brehmer, J., & Louppe, G. (2020). The frontier of simulation-based inference. Proceedings of the National Academy of Sciences, 117(48), 30055–30062. 10.1073/pnas.1912789117 [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Dong, T., Lee, H.-H., Zang, H., Lee, H., Tian, Q., Wan, L., Fan, Q., & Huang, S. (2025). In vivo cortical microstructure mapping using high-gradient diffusion MRI accounting for intercompartmental water exchange effects. NeuroImage, 314, 121258. 10.1016/j.neuroimage.2025.121258 [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Fan, Q., Nummenmaa, A., Witzel, T., Zanzonico, R., Keil, B., Cauley, S., Polimeni, J. R., Tisdall, D., Van Dijk, K. R., Buckner, R. L., Wedeen, V. J., Rosen, B. R., & Wald, L. L. (2014). Investigating the capability to resolve complex white matter structures with high b-value diffusion magnetic resonance imaging on the MGH-USC connectom scanner. Brain Connectivity, 4(9), 718–726. 10.1089/brain.2014.0305 [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Fang, C., Nguyen, V.-D., Wassermann, D., & Li, J.-R. (2020). Diffusion MRI simulation of realistic neurons with SpinDoctor and the neuron module. NeuroImage, 222, 117198. 10.1016/j.neuroimage.2020.117198 [DOI] [PubMed] [Google Scholar]
  19. Fieremans, E., Burcaw, L. M., Lee, H.-H., Lemberskiy, G., Veraart, J., & Novikov, D. S. (2016). In vivo observation and biophysical interpretation of time-dependent diffusion in human white matter. NeuroImage, 129, 414–427. 10.1016/j.neuroimage.2016.01.018 [DOI] [PMC free article] [PubMed] [Google Scholar]
  20. Fieremans, E., Jensen, J. H., & Helpern, J. A. (2011). White matter characterization with diffusional kurtosis imaging. NeuroImage, 58(1), 177–188. 10.1016/j.neuroimage.2011.06.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Fieremans, E., Novikov, D. S., Jensen, J. H., & Helpern, J. A. (2010). Monte Carlo study of a two-compartment exchange model of diffusion. NMR in Biomedicine, 23(7), 711–724. 10.1002/nbm.1577 [DOI] [PMC free article] [PubMed] [Google Scholar]
  22. Germain, M., Gregor, K., Murray, I., & Larochelle, H. (2015). Made: Masked autoencoder for distribution estimation. International Conference on Machine Learning, 37, 881–889. 10.48550/arXiv.1502.03509 [DOI] [Google Scholar]
  23. Henriques, R. N., Jespersen, S. N., & Shemesh, N. (2019). Microscopic anisotropy misestimation in spherical-mean single diffusion encoding MRI. Magnetic Resonance in Medicine, 81(5), 3245–3261. 10.1002/mrm.27606 [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Henschel, L., Conjeti, S., Estrada, S., Diers, K., Fischl, B., & Reuter, M. (2020). FastSurfer - A fast and accurate deep learning based neuroimaging pipeline. NeuroImage, 219, 117012. 10.1016/j.neuroimage.2020.117012 [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Huang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., Fan, Q., Tian, Q., Ramos-Llordén, G., Lee, H.-H., Nummenmaa, A., Bilgic, B., Setsompop, K., Wang, F., Avram, A. V.,… Rosen, B. R. (2021). Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome. NeuroImage, 243, 118530. 10.1016/j.neuroimage.2021.118530 [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Jallais, M., Malaquin, S., Simsek, K., Valette, J., & Palombo, M. (2025). Combining single and double diffusion encoding for improved dendritic spine density estimation with magnetic resonance spectroscopy. Book of Abstracts ESMRMB 2025 Online 41st Annual Scientific Meeting 8–11 October 2025, 23, 24. 10.1007/s10334-025-01278-8 [DOI] [Google Scholar]
  27. Jallais, M., & Palombo, M. (2024). Introducing µGUIDE for quantitative imaging via generalized uncertainty-driven inference using deep learning. eLife, 13, RP101069. 10.7554/eLife.101069 [DOI] [PMC free article] [PubMed] [Google Scholar]
  28. Jallais, M., Rodrigues, P. L. C., Gramfort, A., & Wassermann, D. (2022). Inverting brain grey matter models with likelihood-free inference: A tool for trustable cytoarchitecture measurements. Machine Learning for Biomedical Imaging, 1(IPMI 2021 special issue), 1–28. 10.59275/j.melba.2022-a964 [DOI] [Google Scholar]
  29. Jelescu, I. O., de Skowronski, A., Geffroy, F., Palombo, M., & Novikov, D. S. (2022). Neurite exchange imaging (NEXI): A minimal model of diffusion in gray matter with inter-compartment water exchange. NeuroImage, 256, 119277. 10.1016/j.neuroimage.2022.119277 [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Jelescu, I. O., Palombo, M., Bagnato, F., & Schilling, K. G. (2020). Challenges for biophysical modeling of microstructure. Journal of Neuroscience Methods, 344, 108861. 10.1016/j.jneumeth.2020.108861 [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Jelescu, I. O., Veraart, J., Fieremans, E., & Novikov, D. S. (2016). Degeneracy in model parameter estimation for multi-compartmental diffusion in neuronal tissue: Degeneracy in model parameter estimation of diffusion in neural tissue. NMR in Biomedicine, 29(1), 33–47. 10.1002/nbm.3450 [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Jespersen, S. N., Bjarkam, C. R., Nyengaard, J. R., Chakravarty, M. M., Hansen, B., Vosegaard, T., Østergaard, L., Yablonskiy, D., Nielsen, N. C., & Vestergaard-Poulsen, P. (2010). Neurite density from magnetic resonance diffusion measurements at ultrahigh field: Comparison with light microscopy and electron microscopy. NeuroImage, 49(1), 205–216. 10.1016/j.neuroimage.2009.08.053 [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Jespersen, S. N., Kroenke, C. D., Østergaard, L., Ackerman, J. J., & Yablonskiy, D. A. (2007). Modeling dendrite density from magnetic resonance diffusion measurements. NeuroImage, 34(4), 1473–1486. 10.1016/j.neuroimage.2006.10.037 [DOI] [PubMed] [Google Scholar]
  34. Jones, D., Alexander, D., Bowtell, R., Cercignani, M., Dell’Acqua, F., McHugh, D., Miller, K., Palombo, M., Parker, G., Rudrapatna, U., & Tax, C. (2018). Microstructural imaging of the human brain with a ‘super-scanner’: 10 key advantages of ultra-strong gradients for diffusion MRI. NeuroImage, 182, 8–38. 10.1016/j.neuroimage.2018.05.047 [DOI] [PubMed] [Google Scholar]
  35. Kärger, J. (1985). NMR self-diffusion studies in heterogeneous systems. Advances in Colloid and Interface Science, 23, 129–148. 10.1016/0001-8686(85)80018-X [DOI] [Google Scholar]
  36. Kellner, E., Dhital, B., Kiselev, V. G., & Reisert, M. (2016). Gibbs-ringing artifact removal based on local subvoxel-shifts. Magnetic Resonance in Medicine, 76(5), 1574–1581. 10.1002/mrm.26054 [DOI] [PubMed] [Google Scholar]
  37. Komlosh, M., Horkay, F., Freidlin, R., Nevo, U., Assaf, Y., & Basser, P. (2007). Detection of microscopic anisotropy in gray matter and in a novel tissue phantom using double pulsed gradient spin echo MR. Journal of Magnetic Resonance, 189(1), 38–45. 10.1016/j.jmr.2007.07.003 [DOI] [PubMed] [Google Scholar]
  38. Lasič, S., Chakwizira, A., Lundell, H., Westin, C.-F., & Nilsson, M. (2024). Tuned exchange imaging: Can the filter exchange imaging pulse sequence be adapted for applications with thin slices and restricted diffusion? NMR in Biomedicine, 37(11), e5208. 10.1002/nbm.5208 [DOI] [PMC free article] [PubMed] [Google Scholar]
  39. Lee, H.-H., Papaioannou, A., Novikov, D. S., & Fieremans, E. (2020). In vivo observation and biophysical interpretation of time-dependent diffusion in human cortical gray matter. NeuroImage, 222, 117054. 10.1016/j.neuroimage.2020.117054 [DOI] [PMC free article] [PubMed] [Google Scholar]
  40. Li, H., Zhu, Q., Lu, J., Shen, Y., Zhao, Z., Hsu, Y.-C., Yan, X., Zhang, Y., & Wu, D. (2025). Diffusion-weighted GRASE sequence with 3D navigator for high-resolution time-dependent diffusion MRI in the human cortical gray matter. Magnetic Resonance in Medicine, 94(4), 1654–1662. 10.1002/mrm.30587 [DOI] [PubMed] [Google Scholar]
  41. McKinnon, E. T., Jensen, J. H., Glenn, G. R., & Helpern, J. A. (2017). Dependence on b-value of the direction-averaged diffusion-weighted imaging signal in brain. Magnetic Resonance Imaging, 36, 121–127. 10.1016/j.mri.2016.10.026 [DOI] [PMC free article] [PubMed] [Google Scholar]
  42. Motta, A., Berning, M., Boergens, K. M., Staffler, B., Beining, M., Loomba, S., Hennig, P., Wissler, H., & Helmstaedter, M. (2019). Dense connectomic reconstruction in layer 4 of the somatosensory cortex. Science, 366(6469), eaay3134. 10.1126/science.aay3134 [DOI] [PubMed] [Google Scholar]
  43. Ning, L., Nilsson, M., Lasič, S., Westin, C.-F., & Rathi, Y. (2018). Cumulant expansions for measuring water exchange using diffusion MRI. The Journal of Chemical Physics, 148(7), 074109. 10.1063/1.5014044 [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2018). Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation. NMR in Biomedicine, 32(4), e3998. 10.1002/nbm.3998 [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Novikov, D. S., Veraart, J., Jelescu, I. O., & Fieremans, E. (2018). Rotationally-invariant mapping of scalar and orientational metrics of neuronal microstructure with diffusion MRI. NeuroImage, 174, 518–538. 10.1016/j.neuroimage.2018.03.006 [DOI] [PMC free article] [PubMed] [Google Scholar]
  46. Olesen, J. L., Østergaard, L., Shemesh, N., & Jespersen, S. N. (2022). Diffusion time dependence, power-law scaling, and exchange in gray matter. NeuroImage, 251, 118976. 10.1016/j.neuroimage.2022.118976 [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Özarslan, E., Yolcu, C., Herberthson, M., Knutsson, H., & Westin, C.-F. (2018). Influence of the size and curvedness of neural projections on the orientationally averaged diffusion MR signal. Frontiers in Physics, 6, 17. 10.3389/fphy.2018.00017 [DOI] [PMC free article] [PubMed] [Google Scholar]
  48. Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020). SANDI: A compartment-based model for non-invasive apparent soma and neurite imaging by diffusion MRI. NeuroImage, 215, 116835. 10.1016/j.neuroimage.2020.116835 [DOI] [PMC free article] [PubMed] [Google Scholar]
  49. Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012). Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison. NeuroImage, 59(3), 2241–2254. 10.1016/j.neuroimage.2011.09.081 [DOI] [PubMed] [Google Scholar]
  50. Papamakarios, G., & Murray, I. (2016). Fast ε-free inference of simulation models with Bayesian conditional density estimation. Advances in Neural Information Processing Systems, 29, 1–9. 10.52202/075280-1055 [DOI] [Google Scholar]
  51. Papamakarios, G., Nalisnick, E., Rezende, D. J., Mohamed, S., & Lakshminarayanan, B. (2021). Normalizing flows for probabilistic modeling and inference. The Journal of Machine Learning Research, 22(1), 2617–2680. 10.1017/9781316681411.006 [DOI] [Google Scholar]
  52. Papamakarios, G., Pavlakou, T., & Murray, I. (2017). Masked autoregressive flow for density estimation. Advances in Neural Information Processing Systems, 30. 10.52202/079017-3724 [DOI] [Google Scholar]
  53. Planchuelo-Gómez, Á., Descoteaux, M., Larochelle, H., Hutter, J., Jones, D. K., & Tax, C. M. (2024). Optimisation of quantitative brain diffusion-relaxation MRI acquisition protocols with physics-informed machine learning. Medical Image Analysis, 94, 103134. 10.1016/j.media.2024.103134 [DOI] [PubMed] [Google Scholar]
  54. Popolo, M. P. D., Palombo, M., Planchuelo-Gómez, Á., Tax, C. M. W., & Jallais, M. (2025). Subset selection in diffusion MRI: Uncertainty and degeneracy assessment with µGUIDE. ESMRMB. 10.13140/RG.2.2.17792.29441 [DOI] [Google Scholar]
  55. Quirk, J. D., Bretthorst, G. L., Duong, T. Q., Snyder, A. Z., Springer Jr., C. S., Ackerman, J. J., & Neil, J. J. (2003). Equilibrium water exchange between the intra- and extracellular spaces of mammalian brain. Magnetic Resonance in Medicine, 50(3), 493–499. 10.1002/mrm.10565 [DOI] [PubMed] [Google Scholar]
  56. Reisert, M., Kellner, E., Dhital, B., Hennig, J., & Kiselev, V. G. (2017). Disentangling micro from mesostructure by diffusion MRI: A Bayesian approach. NeuroImage, 147, 964–975. 10.1016/j.neuroimage.2016.09.058 [DOI] [PubMed] [Google Scholar]
  57. Shapson-Coe, A., Januszewski, M., Berger, D. R., Pope, A., Wu, Y., Blakely, T., Schalek, R. L., Li, P. H., Wang, S., Maitin-Shepard, J., Karlupia, N., Dorkenwald, S., Sjostedt, E., Leavitt, L., Lee, D., Bailey, L., Fitzmaurice, A., Kar, R., Field, B., … Lichtman, J. W. (2021). A connectomic study of a petascale fragment of human cerebral cortex (Preprint). Neuroscience. 10.1101/2021.05.29.446289 [DOI] [Google Scholar]
  58. Shemesh, N., Barazany, D., Sadan, O., Bar, L., Zur, Y., Barhum, Y., Sochen, N., Offen, D., Assaf, Y., & Cohen, Y. (2012). Mapping apparent eccentricity and residual ensemble anisotropy in the gray matter using angular double-pulsed-field-gradient MRI. Magnetic Resonance in Medicine, 68(3), 794–806. 10.1002/mrm.23300 [DOI] [PubMed] [Google Scholar]
  59. Shemesh, N., & Cohen, Y. (2011). Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MR: D-PFG reveals microstructures in gray matter. Magnetic Resonance in Medicine, 65(5), 1216–1227. 10.1002/mrm.22738 [DOI] [PubMed] [Google Scholar]
  60. Şimşek, K., Chakwizira, A., Nilsson, M., & Palombo, M. (2025). The role of dendritic spines in water exchange measurements with diffusion MRI: Time-dependent single diffusion encoding MRI. arXiv. 10.48550/arXiv.2506.18229 [DOI] [PubMed] [Google Scholar]
  61. Stejskal, E. O. (1965). Use of spin echoes in a pulsed magnetic-field gradient to study anisotropic, restricted diffusion and flow. The Journal of Chemical Physics, 43(10), 3597–3603. 10.1063/1.1696526 [DOI] [Google Scholar]
  62. Stejskal, E. O., & Tanner, J. E. (1968). Restricted self-diffusion of protons in colloidal systems by the pulsed-gradient, spin-echo method. Journal of Chemical Physics, 49, 1768–1777. 10.1063/1.1670306 [DOI] [Google Scholar]
  63. Truong, T.-K., Guidon, A., & Song, A. W. (2014). Cortical depth dependence of the diffusion anisotropy in the human cortical gray matter in vivo. PLoS One, 9(3), e91424. 10.1371/journal.pone.0091424 [DOI] [PMC free article] [PubMed] [Google Scholar]
  64. Uhl, Q., Pavan, T., Feiweier, T., Piredda, G. F., & Jelescu, I. (2025). Human gray matter microstructure mapped using neurite exchange imaging (NEXI) on a clinical scanner. Imaging Neuroscience, 3, IMAG.a.32. 10.1162/IMAG.a.32 [DOI] [PMC free article] [PubMed] [Google Scholar]
  65. Uhl, Q., Pavan, T., Gerold, J., Chan, K.-S., Jun, Y., Fujita, S., Bhatt, A., Ma, Y., Wang, Q., Lee, H.-H., Huang, S. Y., Bilgic, B., & Jelescu, I. (2025). Reduced NEXI protocol for the quantification of human gray matter microstructure on the Connectome 2.0 scanner. arXiv. 10.48550/ARXIV.2509.09513 [DOI] [Google Scholar]
  66. Uhl, Q., Pavan, T., Molendowska, M., Jones, D. K., Palombo, M., & Jelescu, I. O. (2024). Quantifying human gray matter microstructure using neurite exchange imaging (NEXI) and 300 mT/m gradients. Imaging Neuroscience, 2, 1–19. 10.1162/imag_a_00104 [DOI] [PMC free article] [PubMed] [Google Scholar]
  67. Veraart, J., Fieremans, E., & Novikov, D. S. (2019). On the scaling behavior of water diffusion in human brain white matter. NeuroImage, 185, 379–387. 10.1016/j.neuroimage.2018.09.075 [DOI] [PMC free article] [PubMed] [Google Scholar]
  68. Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016). Denoising of diffusion MRI using random matrix theory. NeuroImage, 142, 394–406. 10.1016/j.neuroimage.2016.08.016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  69. Veraart, J., Nunes, D., Rudrapatna, U., Fieremans, E., Jones, D. K., Novikov, D. S., & Shemesh, N. (2020). Noninvasive quantification of axon radii using diffusion MRI. eLife, 9, 49855. 10.7554/eLife.49855 [DOI] [PMC free article] [PubMed] [Google Scholar]
  70. Williamson, N. H., Ravin, R., Benjamini, D., Merkle, H., Falgairolle, M., O’Donovan, M. J., Blivis, D., Ide, D., Cai, T. X., Ghorashi, N. S., Bai, R., & Basser, P. J. (2019). Magnetic resonance measurements of cellular and sub-cellular membrane structures in live and fixed neural tissue. eLife, 8, e51101. 10.7554/eLife.51101 [DOI] [PMC free article] [PubMed] [Google Scholar]
  71. Yang, D. M., Huettner, J. E., Bretthorst, G. L., Neil, J. J., Garbow, J. R., & Ackerman, J. J. (2018). Intracellular water preexchange lifetime in neurons and astrocytes. Magnetic Resonance in Medicine, 79(3), 1616–1627. 10.1002/mrm.26781 [DOI] [PMC free article] [PubMed] [Google Scholar]
  72. Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012). NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain. NeuroImage, 61(4), 1000–1016. 10.1016/j.neuroimage.2012.03.072 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Material
IMAG.a.1317_supp.pdf (10.4MB, pdf)

Data Availability Statement

The code used in this study is available at https://github.com/mjallais/NEXI_SANDIX_uGUIDE. No new data was created during this study. The data analyzed are from a previously published study and are available from the original data custodians upon reasonable request, subject to a data sharing agreement and ethics approval, as described in https://doi.org/10.1162/imag_a_00104.


Articles from Imaging Neuroscience are provided here courtesy of MIT Press

RESOURCES