Abstract
Background: Current ESC/EACTS guidelines recommend bioprosthetic valves for aortic valve replacement (AVR) in patients > 65 years, yet their use is increasing among younger individuals. The INSPIRIS Resilia (IR) valve, a next-generation bioprosthesis, was designed to improve durability and reduce structural valve degeneration (SVD). This study compares clinical and valve-related outcomes up to six years in patients undergoing AVR with either the IR or its predecessor, the Perimount Magna Ease (PME) valve. Methods: Between January 2017 and December 2023, 2053 patients underwent isolated or combined AVR at a single institution (1602 PME; 451 IR). Propensity-score matching identified 224 patient pairs with comparable baseline characteristics. Outcomes were assessed over follow-up extending up to six years, focusing on cardiovascular and valve-related adverse events. Transvalvular gradients were also assessed at follow-up. Results: After matching, mean age was 64.2 ± 7.7 years in both groups. Freedom from cardiovascular mortality at six years was similar between PME and IR (96.6% vs. 98.2%; p = 0.34), as were rates of stroke, rehospitalization, prosthetic valve endocarditis, and reintervention. A total of 12 PME (5.4%) and six IR valves (2.5%) were explanted during follow-up (p = 0.15), with prosthetic endocarditis representing the leading cause of reintervention. Only one case of severe SVD was observed in both groups. Conclusions: In patients undergoing AVR with comparable baseline risk profiles, IR and PME valves demonstrated similar clinical, valve-related, and hemodynamic outcomes up to six years of follow-up. Prosthetic valve endocarditis represented the leading cause of valve failure, whereas structural valve deterioration remained rare. Longer follow-up and a greater number of valve-related events will be necessary to determine whether differences in bioprosthetic valve degeneration emerge over time.
Keywords: aortic valve replacement, pericardial valve prosthesis, bioprosthesis, Inspiris Resilia valve, Perimount Magna Ease valve, structural valve degeneration
1. Introduction
In line with the latest guidelines, surgical aortic valve replacement (AVR) is indicated for patients younger than 75 years with severe aortic valve disease, with 65 years considered the threshold for selecting a bioprosthetic valve in the aortic position [1,2,3,4]. Nevertheless, over the past decades, there has been a growing trend toward the use of bioprosthetic valves in patients younger than 65 years old [5]. The third-generation stented bovine pericardial prosthesis, the Carpentier-Edwards Perimount Magna Ease (PME), has shown favorable outcomes in terms of durability and safety [6,7,8], with superior performance compared with other bioprosthetic valves, especially in the first 5–7 years from implantation [9,10]. The INSPIRIS Resilia (IR) aortic prosthesis, the most recent addition to the same product line, was developed to enhance durability through innovative tissue preservation technology, with mid-term data confirming its safety and efficacy [11,12]. However, limited real-world evidence is currently available comparing these two generations of prostheses. The aim of this study was to assess and compare the valve-related outcomes of the PME and IR aortic valve prostheses over follow-up extending up to six years in contemporary clinical practice.
2. Methods
2.1. Study Population
Data of all consecutive patients undergoing isolated or combined AVR with PME or IR valves from January 2017 to December 2023 were collected prospectively at the Division of Cardiac Surgery at the Azienda Universitaria Integrata of Verona. Preoperative, intraoperative and postoperative data were collected in a dedicated and anonymized database. All echocardiographic data were retrieved from the Institutional Database of Cardiological Referring Hospitals, which were all accredited to European standards of Echocardiography. Clinical follow-up was accomplished either by querying the Electronic Clinical Chart of each patient (retrieving data from the Regional Health Database) or by interviewing the patient. The study was conducted according to the guidelines of the Declaration of Helsinki and approved by the Ethical Committee of the Azienda Universitaria Integrata of Verona (BBCCH847CESC201, approval date: 22 January 2025). The informed consent was obtained from patients involved in the study.
2.2. EndpPoints
The primary endpoints were valve-related outcomes, including structural valve degeneration (SVD), prosthetic valve endocarditis, and reintervention requiring prosthesis explantation. Secondary endpoints included cardiovascular mortality, stroke, and rehospitalization for cardiovascular causes. SVD and non-SVD were assessed according to the latest Valve Academic Research Consortium-3 (VARC-3) criteria [13].
Follow-up echocardiographic data were obtained from patient interviews, reports provided by referring cardiologists, and the Regional Health Information System. Echocardiographic examinations were therefore performed independently at each patient’s referring center according to routine clinical practice, without centralized image review. Because some echocardiographic variables were inconsistently reported, analyses were restricted to parameters available in at least 50% of examinations, including mean and peak transvalvular gradients, peak velocity, left ventricular ejection fraction, left ventricular end-diastolic volume, and interventricular septal thickness. Accordingly, other prosthetic valve hemodynamic parameters, such as effective orifice area, indexed effective orifice area, Doppler velocity index and acceleration time, were not consistently available and could not be reliably analyzed. Echocardiographic assessments were analyzed at discharge, 1–3 years, and 4–6 years after surgery among patients remaining at risk with an available examination. A size-stratified analysis was also performed at each time point (small: 19–21 mm; medium: 23–25 mm; large: 27–29 mm).
2.3. Statistical Analysis
Descriptive statistics were used to summarize the data. Categorical variables are presented as absolute values and percentages, whereas continuous variables are expressed as mean ± standard deviation (SD) or median with interquartile range (IQR), as appropriate. Categorical variables were compared using the chi-square test or Fisher’s exact test when appropriate, depending on expected cell counts. Continuous variables were tested for normality using the Shapiro–Wilk test and compared using Student’s t-test or Mann–Whitney U test, as appropriate. Propensity score (PS) matching was performed using the nearest-neighbor method with a caliper width of 0.2 of the standard deviation of the logit of the propensity score. Variables included in the PS model were age, sex, body surface area (BSA), and baseline left ventricular ejection fraction (LVEF). These variables were selected a priori based on their established clinical relevance and their potential association with prosthesis selection and outcomes. Given the limited sample size and the need to preserve an adequate matched cohort, the PS model was intentionally restricted to a limited number of clinically relevant covariates. A standardized mean difference (SMD) < 0.10 was considered indicative of adequate balance between groups. Because diabetes mellitus remained the only baseline variable with a clinically relevant residual imbalance after matching (SMD = 0.40), a sensitivity analysis was performed using Cox proportional hazards regression models adjusted for diabetes mellitus. Kaplan–Meier analysis with log-rank testing was used to compare freedom from major valve-related outcomes. Competing risk analysis was performed for prosthetic valve reintervention using the Fine and Gray subdistribution hazard model, considering all-cause death as a competing event. Given the extremely low incidence of structural valve degeneration, competing risk analysis was not applied to this endpoint. Predictors of prosthetic valve endocarditis were assessed in the overall study population using Cox proportional hazards regression analysis. Univariable Cox regression analyses were initially performed including clinically relevant preoperative, intraoperative, and postoperative variables. Variables showing an association with prosthetic valve endocarditis at univariable analysis (p < 0.05) were subsequently entered into the multivariable model. The proportional hazards assumption was assessed using Schoenfeld residuals by testing covariate-by-time interactions. Repeated-measures ANOVA was used to compare echocardiographic parameters across different time points. A two-sided p-value < 0.05 was considered statistically significant. Statistical analyses were performed using SPSS Version 27.0 (IBM Corp., Armonk, NY, USA) and Stata Version 18 (StataCorp, College Station, TX, USA).
3. Results
3.1. Unmatched Population
From 2017 to 2023 a total of 2053 patients underwent isolated or combined AVR: 1602 (78%) received a PME valve, and 451 (22%) patients received an IR valve. Patients receiving PME were older (mean age 72.3 ± 8.8 vs. 59.5 ± 9.6 years old; p < 0.001) and were more likely to be affected by multiple comorbidities (arterial hypertension, dyslipidemia, coronary artery disease, atrial fibrillation, extracardiac arteriopathy), consequently reporting higher EuroSCORE II (5.8 ± 8.3% vs. 2.7 ± 5.4%, p < 0.001). IR patients were more likely to be affected by bicuspid aortic valve disease, diabetes mellitus and chronic pulmonary disease. At the time of surgery, infective endocarditis was present in 85 (5.3%) patients in the PME group and 39 (8.6%) patients in the IR group. Moderate-to-aortic regurgitation was more common in IR population (34.4% vs. 52.9%; p < 0.001). Preoperative clinical and echocardiographic characteristics are shown in Supplemental Tables S1 and S2. Isolated AVR was the most common intervention in both cohorts (47.5% vs. 49.9%; p = 0.37), followed by combined CABG in the PME population and by ascending aorta replacement in the IR population. The most frequently implanted prosthetic sizes were 21, 23 and 25 mm in both groups (Supplemental Table S3). No differences were observed in hospital mortality (0.3% vs. 0.6%; p = 0.15) and in postoperative incidence of major complications, except for pacemaker implantation that was significantly higher in patients implanted with PME (4% vs. 1.8%; p < 0.001) (Supplemental Table S4). During the six years of follow-up, cardiovascular mortality was higher in the PME population (5.2% vs. 2%; p = 0.003). No differences were found in rates of prosthesis explant (2.4% vs. 3.5%; p = 0.28). Two patients in each group underwent reoperation for severe SVD. Infective prosthetic endocarditis represented the leading cause of reintervention in both cohorts (85.7% vs. 84.6%; p = 0.74). Conversely, a higher rate of rehospitalization was observed among patients in the IR group. Detailed rates of all follow-up events are provided in Supplemental Table S5.
3.2. Propensity-Score-Matched Population
After propensity-score matching, baseline characteristics were well balanced between groups. Diabetes mellitus remained the only variable with a standardized mean difference exceeding the conventional threshold (SMD = 0.40), whereas all other baseline covariates showed satisfactory balance. A total of 224 matched pairs of patients receiving a PME or IR valve were analyzed. Mean age was 64.2 ± 7.7 in both groups, which have comparable preoperative risk profiles (EUROscore II 3.2 ± 5.06% vs. 2.7 ± 4.8, p = 0.13; SMD 0.1). At the time of surgery, infective endocarditis was present in 18 (8.0%) patients in the PME group and 13 (5.8%) patients in the IR group. Detailed baseline variables are summarized in Table 1 and Table 2.
Table 1.
Matched population. Baseline characteristics.
| Baseline Characteristics | PME Population (n = 224) | IR Population (n = 224) | p | SMD |
|---|---|---|---|---|
| Age, years | 64.2 (7.7) | 64.2 (7.7) | 0.96 | 0.00 |
| Female sex | 70 (31.3) | 62 (27.7) | 0.41 | 0.08 |
| BSA, m2 | 1.91 (0.23) | 1.93 (0.22) | 0.37 | 0.08 |
| BMI, kg/m2 | 27.3 (4.7) | 26.9 (4.9) | 0.35 | 0.08 |
| Diabetes mellitus | 10 (4.5) | 40 (17.9) | <0.001 | 0.40 |
| COPD | 0 (0.0) | 3 (1.3) | 0.30 | 0.10 |
| Creatinine, mg/dL | 1.01 (0.78) | 1.11 (1.20) | 0.29 | 0.09 |
| Dialysis | 2 (0.9) | 6 (2.7) | 0.15 | 0.13 |
| EuroSCORE II, % | 3.5 (5.1) | 2.7 (4.8) | 0.13 | 0.10 |
| Hypertension | 148 (66.1) | 141 (63.4) | 0.59 | 0.06 |
| Dyslipidemia | 96 (42.9) | 95 (42.4) | 0.92 | 0.01 |
| Peripheral vascular disease | 21 (9.4) | 25 (11.2) | 0.50 | 0.05 |
| Atrial fibrillation | 0.92 | 0.06 | ||
| Paroxysmal | 17 (7.6) | 17 (7.6) | ||
| Persistent | 14 (6.3) | 12 (5.4) | ||
| Pacemaker | 10 (4.5) | 3 (1.3) | 0.08 | 0.13 |
| Prior cardiac surgery | 15 (6.7) | 19 (8.5) | 0.47 | 0.07 |
| Prior AVR | 10 (4.5) | 9 (4.0) | 0.81 | 0.02 |
| Coronary artery disease | 52 (23.2) | 58 (25.9) | 0.51 | 0.06 |
| Endocarditis | 18 (8.0) | 13 (5.8) | 0.35 | 0.07 |
| Aortic dissection | 8 (3.6) | 5 (2.2) | 0.40 | 0.08 |
| Bicuspid aortic valve disease | 53 (23.7) | 50 (22.3) | 0.74 | 0.03 |
AVR: aortic valve replacement; BSA: body surface area; BMI: body mass index; COPD: chronic obstructive pulmonary disease; IR: INSPIRIS RESILIA bioprosthetic valve; PME: Perimount Magna Ease bioprosthetic valve; SMD: standardized mean difference.
Table 2.
Matched population. Preoperative echocardiographic details.
| Baseline Echocardiography | PME Population (n = 224) | IR Population (n = 224) | p |
|---|---|---|---|
| LVEF, % | 55.8 (11.1) | 56.9 (10.7) | 0.29 |
| End-diastolic volume, mL | 152.5 (66.9) | 133.2 (41.7) | 0.02 |
| End-systolic volume, mL | 81.5 (50.1) | 59.9 (30.2) | 0.03 |
| Interventricular septal thickness, mm | 13.1 (3.5) | 13.2 (2.1) | 0.69 |
| Moderate-to-severe aortic stenosis | 146 (65.2) | 144 (64.3) | 0.84 |
| Moderate-to-severe aortic regurgitation | 80 (35.7) | 78 (34.8) | 0.84 |
| Peak transvalvular gradient, mmHg | 62.6 (29.8) | 62.1 (29.9) | 0.91 |
| Mean transvalvular gradient, mmHg | 41.5 (17.8) | 42.5 (15.2) | 0.56 |
| Peak velocity (Vmax), m/s | 3.8 (1.1) | 3.9 (0.8) | 0.91 |
IR: INSPIRIS RESILIA bioprosthetic valve; PME: Perimount Magna Ease bioprosthetic valve; LVEF: left ventricular ejection fraction.
3.2.1. Intraoperative and Postoperative Details
After matching, no differences in the intraoperative details were found. Isolated AVR was the most common operation in both groups, followed by concomitant CABG and ascending aorta replacement. In both cohorts, the most frequently implanted prostheses were the 23 and 25 mm sizes. Postoperative survival was 100% in both groups. No differences were described in major postoperative complications, with exceptions for pacemaker implantation that remained significantly more frequent in the PME group (4% vs. 0.9%; p = 0.002). Intraoperative and postoperative details are reported in Table 3 and Table 4.
Table 3.
Matched population. Intraoperative details.
| Intraoperative Details | PME Population (n = 224) | IR Population (n = 224) | p |
|---|---|---|---|
| Aortic prosthesis size | 0.69 | ||
| 19 mm | 16 (7.2) | 18 (8.1) | |
| 21 mm | 45 (20.2) | 54 (24.1) | |
| 23 mm | 81 (36.2) | 77 (34.4) | |
| 25 mm | 52 (23.2) | 54 (24.1) | |
| 27 mm | 25 (11.2) | 16 (7.1) | |
| 29 mm | 4 (1.8) | 4 (1.8) | |
| Isolated AVR | 106 (47.3) | 120 (53.6) | 0.17 |
| Concomitant procedures | |||
| Mitral valve surgery | 16 (7.1) | 12 (5.4) | 0.43 |
| Root replacement | 30 (13.4) | 6 (2.7) | <0.001 |
| Ascending aorta replacement | 31 (13.8) | 36 (16.1) | 0.51 |
| CABG | 35 (15.6) | 33 (14.7) | 0.79 |
| Other | 39 (17.4) | 39 (17.4) | 1.00 |
| Cardiopulmonary bypass time, min | 125.1 (59.9) | 110.9 (46.7) | 0.007 |
| Aortic cross-clamp time, min | 93.5 (34.7) | 86.9 (34.4) | 0.024 |
| Intra-aortic balloon pump support | 6 (2.7) | 4 (1.8) | 0.52 |
| ECMO support | 1 (0.4) | 2 (0.9) | 0.56 |
| Procedural mortality | 0 (0.0) | 0 (0.0) | — |
AVR: aortic valve replacement; CABG: coronary artery bypass grafting; ECMO: extracorporeal membrane oxygenation; IR: INSPIRIS RESILIA bioprosthetic valve; PME: Perimount Magna Ease bioprosthetic valve.
Table 4.
Matched population. Postoperative details.
| Postoperative Complications | PME Population (n = 224) | IR Population (n = 224) | p |
|---|---|---|---|
| In-hospital mortality | 0 (0.0) | 0 (0.0) | — |
| Length of hospital stay, days | 9.2 (6.7) | 8.1 (7.9) | 0.14 |
| Surgical revision for bleeding | 6 (2.7) | 4 (1.8) | 0.53 |
| Perioperative acute myocardial infarction | 1 (0.4) | 4 (1.8) | 0.31 |
| Atrial fibrillation | 0.61 | ||
| Paroxysmal | 57 (25.4) | 66 (29.5) | |
| Persistent | 3 (1.3) | 3 (1.3) | |
| New permanent pacemaker implantation | 9 (4.0) | 2 (0.9) | 0.002 |
| Stroke | 0.08 | ||
| Transient ischemic attack (TIA) | 3 (1.3) | 1 (0.4) | |
| Minor stroke | 3 (1.3) | 0 (0.0) | |
| Major stroke | 5 (2.2) | 1 (0.4) | |
| Dialysis | 1 (0.4) | 1 (0.4) | 1.00 |
IR: INSPIRIS RESILIA bioprosthetic valve; PME: Perimount Magna Ease bioprosthetic valve; TIA: transient ischemic attack.
3.2.2. Follow-Up Results
The median follow-up was 35.8 months (IQR 22.9–61.7), with a mean follow-up of 42.1 ± 24.8 months (range 0.13–103.6 months). The study population contributed a total of 1571.3 patient-years of follow-up. Freedom from cardiovascular mortality at six years of follow-up was comparable between the two cohorts (96.6% in the PME group vs. 98.2% in the IR group; p = 0.34) (Figure 1). A total of 12 PME valves (5.4%) and six IR valves (2.5%) were explanted during follow-up (p = 0.15), with prosthetic endocarditis representing the leading cause of reintervention (nine [75%] in the PME group vs. five [83%] in the IR group; p = 0.53). During follow-up, infective endocarditis occurred in 24 patients (PME: 15; IR: 9). Early infective endocarditis (≤6 months after surgery) occurred in two patients in the PME group and two in the IR group, whereas late infective endocarditis (>6 months) occurred in 13 and seven patients, respectively. The distribution of early and late events did not differ significantly between prosthesis groups (p = 0.57). One case of severe SVD was observed in both groups. In particular, the IR patient was 66-year-old in chronic dialysis. Two patients in the PME group experienced severe prosthesis–patient mismatch (non-SVD) requiring reoperation. Freedom from prosthesis explant, endocarditis, rehospitalization, and stroke at six years was comparable between groups (Figure 2). The cumulative incidence of reintervention was comparable between groups, with no statistically significant difference between PME and IR valves (subdistribution hazard ratio [SHR] 0.69; 95% CI 0.25–1.91; p = 0.47) (Supplementary Figure S1).
Figure 1.
Matched populations. Kaplan–Meier estimation of freedom from cardiovascular mortality.
Figure 2.
Matched populations. Kaplan–Meier estimation of Freedom from endocarditis (A), from prosthesis explant (B), from stroke (C), and from rehospitalization (D).
Because diabetes mellitus remained the only baseline variable with a clinically relevant residual imbalance after propensity-score matching (SMD = 0.40), a sensitivity analysis adjusting for diabetes mellitus was performed. Adjustment for diabetes mellitus did not materially alter the association between prosthesis type and valve-related outcomes (Supplementary Table S8), supporting the robustness of the primary findings.
In addition, a subanalysis restricted to patients undergoing isolated AVR was also performed; no statistically significant differences were observed between PME and IR groups across any of the evaluated valve-related outcomes (Supplementary Tables S9–S11). Notably, cardiopulmonary bypass and aortic cross-clamp times remained shorter in the IR group, despite the absence of concomitant procedures. This finding may be related to the presence of dry storage, which could facilitate prosthesis preparation and contribute to a more efficient surgical workflow.
3.2.3. Risk Factors for Prosthetic Endocarditis at Follow-Up
Given that prosthetic valve endocarditis represented the leading cause of reintervention during follow-up in both the unmatched and matched population, a Cox proportional hazards regression analysis was performed to identify its independent predictors. Discharge aortic mean gradient (HR 1.075, 95% CI 1.026–1.126; p = 0.003) and cardiopulmonary bypass time (HR 1.006, 95% CI 1.002–1.010; p = 0.007) were independently associated with an increased risk of prosthetic valve endocarditis. Age showed a modest but significant inverse association with the outcome (HR 0.972, 95% CI 0.950–0.994; p = 0.013) (Supplemental Table S7). No significant association was found between prosthesis type and prosthetic valve endocarditis (HR 1.11, 95% CI 0.63–1.95; p = 0.717).
3.2.4. Prosthetic Hemodynamic at Follow-Up
Echocardiographic data at discharge were available in 208/224 (92.9%) patients in the IR group and 198/224 (88.4%) patients in the PME group. Among patients remaining at risk, echocardiographic examinations at 1–3 years were available in 94/178 (52.8%) and 59/181 (32.6%) patients in the IR and PME groups, respectively. At 4–6 years, echocardiographic data were available in 44/62 (71.0%) patients in the IR group and 53/140 (37.9%) patients in the PME group. The analysis of prosthetic hemodynamic revealed initially lower transprosthetic mean gradients at discharge in IR valves, overall (14.1 ± 5.4 mmHg vs. 11.94 ± 4.3 mmHg; p < 0.001), and among all size categories (Figure 3 and Supplemental Table S6). However, mean gradients became comparable between groups during follow-up (13.74 ± 8.1 mmHg vs. 12.95 ± 6.7 mmHg at 1–3 years, p = 0.5; 15.05 ± 5.1 mmHg vs. 14.14 ± 5.6 at 4–6 years, p = 0.18). Transvalvular peak velocities remained similar throughout the entire observation period (Figure 3 and Supplemental Table S6).
Figure 3.
Matched population. Hemodynamic valve performance stratified by size category (small: 19–21 mm; medium: 23–25 mm; large: 27–29 mm) at different time periods (discharge, 1–3 years and 4–6 years).
4. Discussion
This study represents one of the largest and longest propensity-matched comparisons between the PME and the IR prosthesis in contemporary surgical practice. In a matched population with a mean age of 64 years, both prostheses demonstrated comparable valve-related clinical outcomes through six years of follow-up, including cardiovascular mortality, prosthetic valve explantation, structural valve deterioration, stroke, rehospitalization for cardiovascular causes, and overall hemodynamic performance. However, interpretation of long-term hemodynamic comparisons requires caution, as echocardiographic follow-up availability decreased over time and differed between groups. Therefore, late echocardiographic findings should be considered representative of patients with available follow-up data and may have been influenced by differential follow-up completion.
Only a limited number of propensity-score-matched and comparative studies have evaluated outcomes between IR and PME valves, all with short-term follow-up not exceeding three years; these investigations consistently reported similar survival, freedom from major adverse events, and satisfactory hemodynamic performance for both valves, with only minor differences in early postoperative gradients that did not translate into clinically meaningful benefits [14,15,16,17,18]. Our findings are fully consistent with these previous reports while extending the available evidence by providing longer follow-up in a propensity-matched cohort representative of contemporary patients undergoing surgical AVR at relatively young age.
Longer follow-up results of IR valve have been reported by the COMMENCE Trial [19,20]. Comparative analysis of data from the COMMENCE trial and the PARTNER 2A contemporary AVR arm demonstrated lower five-year rates of SVD in patients receiving the IR valve (1.0% vs. 4.8%). Moreover, the use of the IR was associated with a reduced incidence of late adverse valve-related events [20]. However, it is not a direct comparison; populations start from different risk profiles and the type of bioprosthesis in the PARTNER trial is not recognized.
The rationale for comparing these two prostheses derives from their close technological relationship. The PME valve has demonstrated excellent long-term clinical performance and durability, becoming one of the most extensively implanted bovine pericardial bioprostheses worldwide, with consistently low rates of structural valve degeneration over long-term follow-up [6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21]. The IR valve was subsequently developed from the same platform with the specific aim of improving tissue preservation rather than modifying prosthesis design. RESILIA tissue incorporates stable aldehyde capping technology, which neutralizes residual free aldehyde groups within the tissue, thereby reducing calcium-binding sites and limiting mineralization. In addition, glycerol-based preservation avoids permanent glutaraldehyde storage and has been shown in preclinical studies to reduce lipid-mediated calcification and tissue mineralization compared with conventionally treated bovine pericardium [22,23]. These biological characteristics provide the mechanistic rationale for the anticipated improvement in long-term valve durability.
Our study did not demonstrate differences in structural valve deterioration between the two prostheses during the present follow-up. Only one severe SVD event occurred in each group, preventing any robust comparison of long-term valve durability. This observation should not be interpreted as evidence of equivalent durability but rather as confirmation that both prostheses provide excellent mid-term valve-related outcomes with an extremely low incidence of clinically relevant structural valve degeneration. In our cohort, the only patient developing severe SVD after IR implantation was undergoing chronic dialysis, a well-recognized condition to accelerate bioprosthetic valve degeneration through disturbances in calcium-phosphate metabolism and accelerated tissue calcification [3,9,24]. An additional feature of the IR prosthesis is its expandable stent frame, specifically developed to facilitate future transcatheter valve-in-valve procedures. As bioprosthetic valves are increasingly implanted in relatively younger patients, lifetime management strategies have become an important consideration during prosthesis selection. Nevertheless, the long-term effectiveness of valve-in-valve approaches remains uncertain, particularly with respect to prosthesis–patient mismatch, residual transvalvular gradients, coronary access, and durability of subsequent transcatheter prostheses. Whether lifetime management should preferentially rely on future valve-in-valve interventions or on more aggressive surgical strategies at the index operation, including annular or root enlargement to maximize prosthesis size, remains an area of ongoing investigation.
Interestingly, although the rationale for adopting newer bioprosthetic technologies has largely focused on delaying structural valve degeneration, our findings suggest that prosthetic valve endocarditis currently represents a more frequent cause of valve failure than SVD during mid-term follow-up. Approximately 80% of all valve explantations in our series were performed because of infective endocarditis, whereas severe structural valve deterioration remained exceptionally uncommon. This observation is consistent with the evolving epidemiology of prosthetic valve failure. While improvements in tissue preservation have substantially reduced early structural degeneration, prosthetic valve endocarditis remains one of the most devastating complications after surgical valve replacement, accounting for nearly one-third of all cases of infective endocarditis and being associated with high morbidity, mortality, and a frequent need for complex redo surgery [25,26,27,28].
Recent evidence also suggests that the clinical burden of prosthetic valve endocarditis is increasing, likely reflecting the growing number of biological valve implantations, longer patient survival, an aging and increasingly comorbid population, and the expanding use of transcatheter valve therapies and intracardiac devices [25,26,27,28].
Importantly, prosthesis type was not independently associated with prosthetic valve endocarditis in our Cox regression analysis. Although active infective endocarditis at the time of the index operation was considered, detailed microbiological data and other infection-specific risk factors were not systematically available and could not be evaluated. Instead, higher discharge transprosthetic gradients, longer cardiopulmonary bypass time, and younger age emerged as independent predictors, suggesting that the risk of prosthetic valve infection is driven predominantly by patient- and procedure-related factors rather than by prosthesis design itself.
As biological prostheses are increasingly implanted in younger patients and lifetime valve management strategies become more common, the assessment of valve performance should extend beyond durability alone. Future studies should consider prosthetic valve endocarditis as an equally relevant determinant of long-term valve-related outcomes, since freedom from reintervention may ultimately depend on both degenerative and non-degenerative mechanisms of valve failure.
Limitations
Several limitations should be acknowledged. First, this was a retrospective observational study, and residual confounding cannot be completely excluded despite propensity-score matching. The propensity score model was intentionally restricted to clinically relevant baseline variables to balance the need for adequate confounder adjustment with the preservation of a sufficiently large, matched cohort, given the limited sample size and substantial baseline differences between groups. As a consequence, diabetes mellitus represented the only baseline variable with clinically relevant residual imbalance after matching. However, a sensitivity analysis including adjustment for diabetes mellitus yielded consistent results, supporting the robustness of the primary findings.
Second, prosthesis selection was left to surgeon preference and may therefore have introduced selection bias. Nevertheless, this reflects contemporary real-world surgical practice and enhances the external validity of our results. Although both prostheses were implanted during the same study period, the IR valve was progressively adopted in routine clinical practice following its introduction, resulting in shorter follow-up availability and fewer patients remaining at risk at later time points. This temporal implantation pattern should be considered when interpreting longitudinal echocardiographic analyses.
Third, follow-up echocardiography was performed independently at referring institutions according to routine clinical practice, without centralized image review. Consequently, some echocardiographic variables were incompletely reported, precluding a comprehensive assessment of prosthetic valve hemodynamics. Longitudinal imaging data were unavailable for all patients, and interobserver variability cannot be excluded, although this limitation is expected to have similarly affected both study groups.
Finally, the very low incidence of severe structural valve deterioration, with only one event observed in each group, precludes any definitive comparison of long-term prosthetic durability. Although this finding is reassuring from a clinical perspective, it precludes any robust comparison of structural valve degeneration between prostheses and limits the ability to draw definitive conclusions regarding comparative long-term durability. Therefore, the present study should be interpreted primarily as an assessment of clinical, valve-related, and hemodynamic outcomes.
5. Conclusions
In patients undergoing surgical AVR with comparable baseline risk profiles, the IR and PME bioprostheses demonstrated similar valve-related clinical and hemodynamic outcomes during six years of follow-up. While both prostheses exhibited excellent mid-term performance with an extremely low incidence of SVD, prosthetic valve endocarditis emerged as the leading cause of valve failure and reintervention in contemporary practice. These findings suggest that, as the durability of surgical bioprostheses continues to improve, future investigations should evaluate both degenerative and non-degenerative mechanisms of valve failure. Longer follow-up will be necessary to determine whether the tissue preservation technology of the IR valve ultimately translates into superior long-term durability.
Acknowledgments
During the preparation of this manuscript/study, the authors used ChatGTP-5.6 Sol for the English language editing and table formatting. The authors have reviewed and edited the output and take full responsibility for the content of this publication.
Abbreviations
| AVR | Aortic valve replacement |
| BMI | Body mass index |
| BSA | Body surface area |
| CABG | Coronary artery bypass grafting |
| CI | Confidence interval |
| COPD | Chronic obstructive pulmonary disease |
| ECMO | Extracorporeal membrane oxygenation |
| EO | Early onset |
| EACTS | European Association for Cardio-Thoracic Surgery |
| ESC | European Society of Cardiology |
| HR | Hazard ratio |
| IABP | Intra-aortic balloon pump |
| IQR | Interquartile range |
| IR | INSPIRIS RESILIA bioprosthetic valve |
| LVEF | Left ventricular ejection fraction |
| LO | Late onset |
| NYHA | New York Heart Association |
| PME | Perimount Magna Ease bioprosthetic valve |
| PPM | Prosthesis–patient mismatch |
| PS | Propensity score |
| PVE | Prosthetic valve endocarditis |
| SD | Standard deviation |
| SMD | Standardized mean difference |
| SVD | Structural valve degeneration |
| TIA | Transient ischemic attack |
| VARC-3 | Valve Academic Research Consortium-3 |
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/medsci14030411/s1, Table S1: Unmatched population. Preoperative charatcteristics; Table S2: Unmatched population. Preoperative echocardiographic details; Table S3: Unmatched population. Intraoperative details; Table S4: Unmatched population. Postoperative complications; Table S5: Unmatched population. Follow-up events; Table S6: Matched population. Echocardiographic data stratified by size-category and time-period.; Table S7: Cox regression analysis of predictors of prosthetic endocarditis at follow-up; Table S8: Sensitivity analysis adjusting for diabetes mellitus in the propensity-matched cohort; Table S9: Sub analysis of Isolated AVR group. Preoperative details; Table S10: Sub analysis of Isolated AVR group. Intra and Postoperative details; Table S11: Subanalysis of Isolated AVR group. Kaplan–Meier Estimates of Freedom from Clinical Events. Figure S1: Cumulative incidence function (CIF) of prosthetic valve reintervention in PME and IR groups, with death as a competing risk (Fine and Gray model). No significant difference was observed between groups.
Author Contributions
Conceptualization, G.B.L.; methodology, A.F.; software, A.F.; validation, A.F. and F.P.; formal analysis, A.F.; investigation, F.P., M.T.D. and I.M.; resources, I.M.; data curation, F.P.; writing—original draft preparation, A.F.; writing—review and editing, G.B.L.; visualization, A.F.; supervision, G.B.L.; project administration, A.F. All authors have read and agreed to the published version of the manuscript.
Institutional Review Board Statement
The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of the Azienda Universitaria Integrata di Verona (BBCCH847CESC201, approval date: 22 January 2025).
Informed Consent Statement
Informed consent was obtained from all subjects involved in the study.
Data Availability Statement
The original contributions presented in this study are included in the article/Supplementary Materials. Further inquiries can be directed to the corresponding author.
Conflicts of Interest
The authors declare no conflicts of interest. Funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.
Funding Statement
This research received no external funding.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
- 1.Praz F., Borger M.A., Lanz J., Marin-Cuartas M., Abreu A., Adamo M., Marsan N.A., Barili F., Bonaros N., Cosyns B., et al. 2025 ESC/EACTS Guidelines for the Management of Valvular Heart Disease. Eur. Heart J. 2025;46:ehaf194. doi: 10.1093/eurheartj/ehaf194. [DOI] [PubMed] [Google Scholar]
- 2.Otto C.M., Nishimura R.A., Bonow R.O., Carabello B.A., Erwin J.P., Gentile F., Jneid H., Krieger E.V., Mack M., McLeod C., et al. 2020 ACC/AHA Guideline for the Management of Patients with Valvular Heart Disease: Executive Summary. Circulation. 2021;143:e35–e71. doi: 10.1161/CIR.0000000000000932. [DOI] [PubMed] [Google Scholar]
- 3.Bismee N.N., Javadi N. Bioprosthetic Aortic Valve Degeneration after TAVR and SAVR: Incidence, Diagnosis, Predictors, and Management. J. Cardiovasc. Dev. Dis. 2024;11:384. doi: 10.3390/jcdd11120384. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Malvindi P.G., Luthra S., Olevano C., Salem H., Kowalewski M., Ohri S. Aortic Valve Replacement with Biological Prosthesis in Patients Aged 50–69 Years. Eur. J. Cardiothorac. Surg. 2021;59:1077–1086. doi: 10.1093/ejcts/ezaa429. [DOI] [PubMed] [Google Scholar]
- 5.Isaacs A.J., Shuhaiber J., Salemi A., Isom O.W., Sedrakyan A. National Trends in Utilization and In-Hospital Outcomes of Mechanical Versus Bioprosthetic Aortic Valve Replacements. J. Thorac. Cardiovasc. Surg. 2015;149:1262–1269.e3. doi: 10.1016/j.jtcvs.2015.01.052. [DOI] [PubMed] [Google Scholar]
- 6.Francica A., Benvegnù L., Biagio L.S., Tropea I., Luciani G.B., Faggian G., Onorati F. Ten-Year Clinical and Echocardiographic Follow-Up of Third-Generation Biological Prostheses in the Aortic Position. J. Thorac. Cardiovasc. Surg. 2024;167:1705–1713.e8. doi: 10.1016/j.jtcvs.2022.10.023. [DOI] [PubMed] [Google Scholar]
- 7.Piperata A., Fiocco A., Cavicchiolo A., Ponzoni M., Pesce R., Gemelli M., Evangelista G., Gastino E., Michelotti S., Mazzaro E., et al. Carpentier-Edwards Magna Ease Bioprosthesis: A Multicentre Clinical Experience and 12-Year Durability. Eur. J. Cardiothorac. Surg. 2022;61:888–896. doi: 10.1093/ejcts/ezab552. [DOI] [PubMed] [Google Scholar]
- 8.Anselmi A., Aymami M., Tomasi J., D’aLessandro G., Langanay T., Corbineau H., Mancini J., Flecher E., Verhoye J.-P. Late Clinical and Echocardiographic Results with the Magna Ease Pericardial Aortic Bioprosthesis. Eur. J. Cardiothorac. Surg. 2024;65:ezad351. doi: 10.1093/ejcts/ezad351. [DOI] [PubMed] [Google Scholar]
- 9.Squiers J.J., Robinson N.B., Audisio K., Ryan W.H., Mack M.J., Rahouma M., Cancelli G., Kirov H., Doenst T., Gaudino M., et al. Structural Valve Degeneration of Bioprosthetic Aortic Valves: A Network Meta-Analysis. J. Thorac. Cardiovasc. Surg. 2023;166:52–59. doi: 10.1016/j.jtcvs.2021.12.047. [DOI] [PubMed] [Google Scholar]
- 10.Caporali E., Bonato R., Klersy C., Ferrari E. Hemodynamic Performance and Clinical Outcome of Pericardial PERIMOUNT Magna and Porcine Hancock-II Valves in Aortic Position. J. Card. Surg. 2019;34:1055–1061. doi: 10.1111/jocs.14212. [DOI] [PubMed] [Google Scholar]
- 11.Bavaria J.E., Griffith B., Heimansohn D.A., Rozanski J., Johnston D.R., Bartus K., Girardi L.N., Beaver T., Takayama H., Mumtaz M.A., et al. Five-Year Outcomes of the COMMENCE Trial Investigating Aortic Valve Replacement with RESILIA Tissue. Ann. Thorac. Surg. 2023;115:1429–1436. doi: 10.1016/j.athoracsur.2021.12.058. [DOI] [PubMed] [Google Scholar]
- 12.Onorati F., Geisler D., Theron A., Francica A., Caruso V., Mariani C., Fiore A., Hegeman R., Porto A., Folliguet T., et al. Five-Year Results of Aortic Valve Replacement with a Novel Bioprosthesis: Real-World Data from a Large Multicenter Registry. Ann. Thorac. Surg. 2025;121:127–136. doi: 10.1016/j.athoracsur.2025.03.015. [DOI] [PubMed] [Google Scholar]
- 13.Généreux P., Piazza N., Alu M.C., Nazif T., Hahn R.T., Pibarot P., Bax J.J., Leipsic J.A., Blanke P., Blackstone E.H., et al. Valve Academic Research Consortium 3: Updated Endpoint Definitions for Aortic Valve Clinical Research. J. Am. Coll. Cardiol. 2021;77:2717–2746. doi: 10.1016/j.jacc.2021.02.038. [DOI] [PubMed] [Google Scholar]
- 14.Francica A., Tonelli F., Rossetti C., Galeone A., Perrone F., Luciani G.B., Onorati F. Perimount MAGNA Ease Versus INSPIRIS RESILIA Valve: A Propensity Score-Matched Analysis of Hemodynamic Performance in Patients Below 70 Years of Age. J. Clin. Med. 2025;in press doi: 10.3390/jcm12052077. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Saiydoun G., Nassar E., Saadé S., Aludaat C., Rubin S., Alqdeimat I., Ruggieri V.G. Mid-Term Outcomes after Aortic Valve Replacement in Patients Under 70: A Comparative Study of INSPIRIS RESILIA Versus PERIMOUNT MAGNA EASE Bioprostheses. Interdiscip. Cardiovasc. Thorac. Surg. 2025;40:ivaf169. doi: 10.1093/icvts/ivaf169. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Bernard J., Georges G., Hecht S., Pibarot P., Clavel M.-A., Babaki S., Kalavrouziotis D., Mohammadi S. Mid-Term Clinical and Echocardiographic Results of the INSPIRIS RESILIA Aortic Valve: A Retrospective Comparison to the Magna Ease. Interdiscip. Cardiovasc. Thorac. Surg. 2023;37:ivad117. doi: 10.1093/icvts/ivad117. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Maeda K., Shimamura K., Yoshioka D., Inoue K., Yamada S., Yamashita K., Kawamura A., Hiraoka A., Yoshitaka H., Kitabayashi K., et al. Midterm Outcomes After Surgical Aortic Valve Replacement with the INSPIRIS RESILIA from a Multicenter AVR Registry. J. Cardiol. 2023;82:261–267. doi: 10.1016/j.jjcc.2023.05.012. [DOI] [PubMed] [Google Scholar]
- 18.D’oNofrio A., Cibin G., Tessari C., Lorenzoni G., Luzi G., Manzan E., Gregori D., Gerosa G. INTU-ITA and RES-ITA Investigators. Multicenter, Propensity-Weighted Comparison of Stented, Rapid-Deployment and New-Generation Aortic Valves. Int. J. Cardiol. Heart Vasc. 2024;54:101487. doi: 10.1016/j.ijcha.2024.101487. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Beaver T., Bavaria J.E., Griffith B., Svensson L.G., Pibarot P., Borger M.A., Sharaf O.M., Heimansohn D.A., Thourani V.H., Blackstone E.H., et al. Seven-Year Outcomes Following Aortic Valve Replacement with a Novel Tissue Bioprosthesis. J. Thorac. Cardiovasc. Surg. 2024;168:781–791. doi: 10.1016/j.jtcvs.2023.09.047. [DOI] [PubMed] [Google Scholar]
- 20.Bartus K., Bavaria J.E., Thourani V.H., Xu K., Keuffel E.L. Structural Hemodynamic Valve Deterioration Durability of RESILIA Tissue Versus Contemporary Aortic Bioprostheses. J. Comp. Eff. Res. 2023;12:e220180. doi: 10.2217/cer-2022-0180. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Bourguignon T., Bouquiaux-Stablo A.-L., Candolfi P., Mirza A., Loardi C., May M.-A., El-Khoury R., Marchand M., Aupart M. Very Long-Term Outcomes of the Carpentier-Edwards PERIMOUNT Valve in Aortic Position. Ann. Thorac. Surg. 2015;99:831–837. doi: 10.1016/j.athoracsur.2014.09.030. [DOI] [PubMed] [Google Scholar]
- 22.Flameng W., Hermans H., Verbeken E., Meuris B. A Randomized Assessment of an Advanced Tissue Preservation Technology in the Juvenile Sheep Model. J. Thorac. Cardiovasc. Surg. 2015;149:340–345. doi: 10.1016/j.jtcvs.2014.09.062. [DOI] [PubMed] [Google Scholar]
- 23.De La Fuente A.B., Wright G.A., Olin J.M., Duhay F.G., Kapelak B., Bochenek M., Bartus K., Sadowski J. Advanced Integrity Preservation Technology Reduces Bioprosthesis Calcification while Preserving Performance and Safety. J. Heart Valve Dis. 2015;24:101–109. [PubMed] [Google Scholar]
- 24.Rodríguez-Gabella T., Voisine P., Puri R., Pibarot P., Rodés-Cabau J. Aortic Bioprosthetic Valve Durability: Incidence, Mechanisms, Predictors, and Management of Surgical and Transcatheter Valve Degeneration. J. Am. Coll. Cardiol. 2017;70:1013–1028. doi: 10.1016/j.jacc.2017.07.715. [DOI] [PubMed] [Google Scholar]
- 25.Hadji-Turdeghal K., Jensen A.D., Bruun N.E., Iversen K.K., Bundgaard H., Smerup M., Kober L., Østergaard L., Fosbøl E.L. Temporal Trends in the Incidence of Infective Endocarditis in Patients with a Prosthetic Heart Valve. Open Heart. 2023;10:e002269. doi: 10.1136/openhrt-2023-002269. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Delgado V., Marsan N.A., de Waha S., Bonaros N., Brida M., Burri H., Caselli S., Doenst T., Ederhy S., Erba P.A., et al. 2023 ESC Guidelines for the Management of Endocarditis. Eur. Heart J. 2023;44:3948–4042. doi: 10.1093/eurheartj/ehad193. [DOI] [PubMed] [Google Scholar]
- 27.Habib G., Erba P.A., Iung B., Donal E., Cosyns B., Laroche C., Popescu B.A., Prendergast B., Tornos P., Sadeghpour A., et al. Clinical Presentation, Aetiology and Outcome of Infective Endocarditis: Results of the ESC-EORP EURO-ENDO Registry. Eur. Heart J. 2019;40:3222–3232. doi: 10.1093/eurheartj/ehz620. [DOI] [PubMed] [Google Scholar]
- 28.Pettersson G.B., Hussain S.T. Current AATS Guidelines on Surgical Treatment of Infective Endocarditis. J. Thorac. Cardiovasc. Surg. 2017;153:1241–1258.e29. doi: 10.1016/j.jtcvs.2016.09.093. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The original contributions presented in this study are included in the article/Supplementary Materials. Further inquiries can be directed to the corresponding author.