Published in final edited form as: Phys Fluids (1994). 2025 Sep 30;37(9):091926. doi: 10.1063/5.0287796

Establishing Hemodynamic Convergence Framework for Coronary Digital Twins Under Realistic Dynamic Heart Rates

Nusrat Sadia Khan 1, Cyrus Tanade 1, Justen Geddes 1, Amanda Randles 1
PMCID: PMC13425941  NIHMSID: NIHMS2182208  PMID: 42540504

Abstract

The advent of digital twins has increased the demand for longer-duration simulations that span multiple physiological states. Digital twins have emerged as powerful tools in cardiovascular modeling, enabling patient-specific simulations of coronary blood flow for non-invasive diagnosis and treatment planning. Although these simulations achieve high fidelity under steady or periodic heart rates, modeling real-world transitions, such as those arising from physical activity, requires careful evaluation of temporal convergence, the stabilization of hemodynamic parameters through the simulation of preceding cardiac cycles, or ‘pre-flows’. In this study, we present a physiologically grounded approach for determining the minimum number of preceding cardiac pre-flows necessary to achieve temporal convergence following abrupt heart rate (HR) changes. Using high-resolution patient-specific 3-dimensional (3D) simulations and inflow waveforms scaled from both synthetic and wearable-derived HR data, we quantify convergence behavior across velocity, pressure gradient, and wall shear stress at both cross-sectional and full-domain levels. Results show that simulating just two pre-flows is sufficient to achieve physiologically stable outputs across high-to-low and low-to-high HR transitions (<2% difference). These findings are further verified using continuous HR data obtained from wearable devices, with low and high HR segments extracted to represent natural extremes, confirming the robustness of the proposed convergence criterion under real-world dynamic inputs (<1% difference). This work establishes a computationally efficient and physiologically consistent criterion for dynamic-state simulations, facilitating the integration of cardiovascular digital twins with real-time sensing technologies.

I. INTRODUCTION

The rise of digital twins in cardiovascular medicine has created new demands for simulations that capture not just static physiological states, but dynamic transitions over time. These state-of-the-art models, designed to reflect patient-specific anatomy and evolving heart rate (HR) conditions, reform how we understand and predict vascular health. However, their clinical potential hinges on an often overlooked technical foundation: temporal convergence. That is, ensuring that the simulated hemodynamics reflect the true physiology rather than the artifacts of the initialization of the model. This requirement becomes especially critical when digital twins incorporate real-world transitions, such as rest to higher HR-scaled inflow conditions, where flow inputs evolve rapidly and boundary conditions change over time.

Although many existing cardiovascular digital twin studies are limited to single heartbeat analyzes under static conditions, typically representative beats entirely in rest or exercise states1–8, they do not address transitions between these HR conditions. This leaves a gap in the guidance to ensure convergence when sharp physiological changes occur. For applications of longitudinal monitoring, such as predicting vascular disease progression or detecting restenosis in the stent, the ability to track the hemodynamic state of a patient throughout dynamic HR changes spanning naturally occurring low and high HR ranges, such as those captured by wearable devices, is essential. In these scenarios, accurate modeling requires that the simulated flow fields converge reliably after each state change. Identifying the first convergent heartbeat ensures that clinically relevant metrics, such as fractional flow reserve or pressure–flow relationships, are derived from physiologically stable outputs without unnecessary simulation overhead, enabling efficient real-time and remote assessments.

Accurate hemodynamic simulations are critically dependent on temporal convergence, stabilization of flow fields after initial transients have dissipated, so that the computed outputs reflect true physiological behavior rather than numerical artifacts9–11. This requirement becomes even more essential in coronary digital twins12,13 that dynamically replicate the physiological state of a patient and aim to replicate dynamic heart rate (HR) conditions, where flow inputs change rapidly in response to activity or stress14. Without a reliable convergence framework, simulations risk misrepresenting clinically important hemodynamic biomarkers, especially in regions of stenosis or complex geometry. Moreover, as wearable technologies increasingly enable longitudinal tracking, the ability to integrate these data into accurate15–17, stable simulations becomes essential for the real-world deployment of digital twin systems in cardiovascular medicine18–22. The objective of this work is to establish a physiologically grounded and computationally efficient criterion for temporal convergence in 3-dimensional (3D) coronary blood flow simulations under dynamic HR transitions. This criterion is fundamental to enabling digital vascular twins to move beyond static snapshots of disease and toward state-of-the-art real-time models capable of tracking cardiovascular physiology through continuous changes.

Vascular digital twins, based on high-fidelity computational fluid dynamics (CFD), have been proven to be valuable for non-invasive diagnosis, risk stratification, and treatment planning by simulating pressure, velocity, and wall shear stress (WSS) in patient-specific coronary anatomies5–8,23. These models enable patient-specific assessments and in silico treatment planning, offering a powerful complement to invasive procedures24–27. Despite advances in model fidelity and clinical relevance, most existing digital twin frameworks operate over short temporal windows, often spanning only one or a few cardiac cycles1–4,28,29. Simulations are typically constructed and validated under static or idealized physiological states, such as resting heart rate and fixed boundary conditions1,3. Even as CFD solvers have matured to support large-scale 3D flow modeling, their application to dynamic, time-varying conditions remains limited. In particular, it is still uncommon for digital twins to incorporate continuous dynamic HR transitions across physiological ranges, such as abrupt increases or decreases in heart rate, within a single unified simulation.

Recent advances in sensing and computational infrastructure are beginning to make state-varying simulations in the longer term feasible30,31. However, this shift introduces a new challenge: when simulating a dynamically changing HR profile, how many preceding cardiac cycles must be included to ensure the solution is free from initialization transients and yields physiologically accurate hemodynamic outputs? Most prior work has focused on achieving convergence in periodic or steady-state settings4,32, but little is known about convergence behavior when modeling large transitions in input conditions, such as an abrupt HR increase or decrease. In addition, convergence is often assessed in single cross sections, which can miss critical spatial variations in complex stenosed anatomies where local flow features are highly sensitive to upstream changes14.

This study evaluates how abrupt changes in heart rate affect the convergence of patient-specific coronary flow simulations, with a focus on pressure, velocity, and WSS computed in both localized slices and throughout the vascular domain. The analysis spans synthetic transitions designed to bracket physiological extremes, as well as wearable-derived heart rate sequences that reflect real-world variability. The convergence behavior is examined across anatomical regions and hemodynamic metrics, revealing that flow fields typically stabilize after two cardiac cycles, regardless of the direction of transition or the input source. This result establishes a practical and physiologically justified standard for initializing simulations under dynamic conditions. The findings support the extension of vascular digital twins beyond static evaluations toward continuous, time-aware modeling, enabling broader integration with real-time sensing technologies in both clinical and remote settings. Moreover, by quantitatively characterizing convergence under dynamic HR transitions, this work strengthens the modeling foundations for the longitudinal hemodynamic mapping framework which aims to enable wearable-informed real-time coronary simulations30,31.

II. METHODS

A. Patient data and power analysis

To evaluate convergence behavior under real-world conditions, this study leveraged a robust dataset of previously collected, de-identified patient cases with confirmed coronary artery disease. No new patient recruitment, experimentation, or interaction was conducted. Instead, the coronary geometries used in this analysis were drawn from a validated dataset originally published in a prior study on non-invasive computation of fractional flow reserve using digital twins5. That study included 160 patients with angiographically confirmed disease, and was approved for retrospective analysis of coronary angiograms and associated clinical measurements. As the original data collection involved no direct patient contact, signed informed consent was not required.

For the current analysis, we began with the cohort of 160 previously processed left coronary artery (LCA) geometries. A two-sample t-test was performed to determine the minimum sample size required to detect statistically significant differences in L2 error between simulation groups. An L2 error threshold of 10−3 was adopted, consistent with prior CFD studies involving patient-derived geometries that report this limit as an accepted numerical accuracy criterion1,33–37. The maximum expected error was set to 0.007, corresponding to the largest deviation observed in the cohort. The standard deviation was taken as 0.003, consistent with the findings of Vardhan et al.1, who reported a mean bias of approximately 0.003 for resting gradients when validating computational and angiographic pressure gradients. These values remained stable within 95% agreement limits, demonstrating that a standard deviation on the order of 0.003 is representative of rigorous coronary CFD comparisons. Using these parameters, the t-test indicated that N=6 representative LCA models would be sufficient to achieve statistical power for the specified effect size. Six models were therefore selected from the cohort to capture a broad range of anatomical and physiological variability, including differences in fluid domain volume, Euclidean distances between main branch radii, degrees of stenosis, and distribution across fractional flow reserve (FFR) classification categories (see Supplementary Table SI). Furthermore, continuous HR data from a different individual, spanning one hour and capturing extreme low and high HR segments within the recording, were sourced from an open access FitBit dataset38.

The algorithm described in previous studies was utilized to reconstruct the entire coronary tree model from pairs of coronary angiograms39,40. The processes of reconstruction of angiograms and recording of clinical measurements of aortic blood pressure, cardiac output, baseline heart rate, and hematocrit for the construction of a personalized digital twin are described in5,30,31,33,41.

B. Coronary Geometry Reconstruction and Computational Flow Modeling

To generate anatomically accurate digital twin models, patient-specific 3D coronary artery geometries were reconstructed from paired coronary angiograms using a previously established and validated reconstruction pipeline39,40. The reconstruction pipeline generated 2D vessel centerlines with associated diameters, which were then used to automatically compute full 3D coronary tree geometries. This method has been extensively validated and applied in prior work5,30,31,33,41.

Hemodynamic simulations were performed using HARVEY, a massively parallel fluid dynamics solver based on the lattice Boltzmann method (LBM)42,43. The solver uses a D3Q19 velocity discretization and single-relaxation-time Bhatnagar–Gross–Krook (BGK) collision operator to solve the Navier-Stokes equations. The lattice Boltzmann equation governs the time evolution of the particle distribution function fi(x,t) as:

fix+ciΔt,t+Δt=fi(x,t)+Ωi(x,t) (1)

where ci denotes the discrete lattice velocities and Ωi is the collision term. No-slip boundary conditions were enforced on rigid vessel walls using the halfway bounce-back method, while finite-difference boundary conditions were applied at the inlet and outlets44. All simulations were run on the Duke Compute Cluster using 1440 CPU tasks across 36 Intel Xeon E5–2695V4 ’Broadwell’ nodes.

Blood was modeled as an incompressible Newtonian fluid with a density of 1060 kg/m3. The dynamic viscosity values were derived from the measured hematocrit level (ϕ) using the empirical relationship45:

μ=μ01-ϕ (2)

where μ0=1.2cP is the assumed plasma viscosity1,33,45. The baseline clinical and geometric characteristics, including hematocrit, viscosity, severity of stenosis, FFR, and mesh resolution are summarized in Supplementary Table SI for the six geometries of the left coronary artery selected for this study.

Inlet flow waveforms were generated by scaling a representative coronary velocity profile46 according to patient-specific baseline cardiac output and resting HR (HRbaseline). The baseline coronary flow rate was estimated using the following:

Qbaseline=αQSVHRbaseline (3)

assuming a constant stroke volume QSV, approximated from clinical cardiac (CO) output data, and a literature-based coronary flow fraction, α47,48. To model dynamic conditions, the waveform was scaled to reflect instantaneous HR (HRinstant), using the corresponding coronary ostial area Aostial to calculate the maximum inlet velocity:

vmax=2QbaselineAostial⋅HRinstantHRbaseline (4)

The cardiac period was scaled according to the following:

τcardiac=60HRinstant (5)

This scaling approach was adopted intentionally to maintain consistent boundary conditions across cases and isolate HR as the primary variable of interest when assessing temporal convergence behavior, particularly for the largest possible shift between two consecutive cardiac cycles. By keeping waveform characteristics such as the systolic-to-diastolic ratio constant, any observed differences in convergence could be attributed solely to heart rate changes. In patient-specific coronary artery simulations, waveforms are often filtered and scaled to patient-specific blood pressures and heart rates at rest and stress to enable controlled comparisons between states49. Prior CFD models of coronary flow have similarly scaled resting waveforms by flow reserve factors to represent hyperemia, preserving waveform morphology while varying flow or heart rate to isolate specific effects50. Such scaling approaches are widely used in cardiovascular modeling to reduce complexity and focus on primary variables while maintaining a consistent baseline waveform shape for controlled analysis51.

We employed constant 2-element Windkessel models for the outlet boundary condition, consisting of peripheral resistance (Rp) and compliance (C). The Windkessel models were applied to the ends of each terminal branch to account for microvascular hemodynamics52:

Q=PRp+CdPdt (6)

C was assumed to be constant at 1 × 10−12 m3mmHg−1 based on53. Rp was distributed among the terminal vessels using relationships commonly used for patient-specific coronary simulations1,33,41,47,54:

Ri=Pmean∑j=1Nterminalrj3Qostialri3 (7)

where Ri is the peripheral resistance in each terminal vessel, Pmean is the mean arterial pressure, Qostial is ostial flow rate, r is the radius of the average terminal branch, and Nterminal is the number of terminal branches. We used a constant ostial flow rate in the resting state to parameterize the outflow conditions.

Pmean was computed from measured systolic and diastolic blood pressures (SBP and DBP, respectively):

Pmean=SBP+2DBP3. (8)

Patient-level SBP, DBP, CO, dominance, and terminal-branch counts are provided in Supplementary Table S2.

C. Hemodynamic Parameter Analysis

Three key hemodynamic parameters were evaluated in this study across all simulations: pressure distribution, velocity, and WSS. The pressure values computed in the lattice units were converted to physical units using a calibrated transformation by the Boltzmann density field of the lattice and matched to clinical manometric pressure data, following the procedure described in1,5. To assess the pressure drop across the lesion, we computed the pressure gradient (PG) along the left anterior descending artery (LAD) in multiple cross-sectional slices. PG was defined as the ratio of beat-averaged cross-section-averaged pressure downstream of the stenosis Pd to that at the ostium Pa:

PG=PdPa (9)

For complete 3D comparisons, the pressure distribution was evaluated point-wise across all fluid nodes in the domain. Velocity was extracted both as pointwise velocity vectors and as cycle-averaged magnitudes at each lattice point. WSS was computed at fluid nodes adjacent to vessel walls using a method adapted from55, with the WSS vector τi given by:

τi=-μωcs2ρfαneqcαjnjcαj-cαknink (10)

where fαneq is the non-equilibrium distribution function, μ is the blood viscosity, ω is the relaxation rate, ρ is the fluid density, cαj is the lattice velocity vector, and nj is the outward unit normal at the vessel wall. The magnitude of WSS was computed as the norm of τi. To evaluate differences across simulation conditions, we performed pointwise comparisons of WSS magnitude for each geometry and computed the distribution of absolute differences across all cases.

D. Evaluation

metrics and tolerance To assess the convergence of hemodynamic waveforms, we employed two complementary evaluation metrics: the percent difference and difference in relative L2 norm. Percent difference provides a relative measure of deviation between two time-varying waveforms and is defined as:

Percentdifference=∑x→1-x→2∑x→2×100 (11)

Here, x→1 and x→2 are vectors representing the evaluated and reference waveforms, respectively, over 40 time points of a cardiac cycle at a given cross-sectional slice. This metric is well suited for slice-based comparisons with relatively few spatial points, where cumulative absolute differences provide an interpretable measure of localized hemodynamic variation31,32. The relative L2 norm quantifies spatial deviations between two solutions across the full 3D domain and is computed as:

RelativeL2norm=y→1-y→22∑y→22 (12)

Here, y→1 and y→2 are vectors containing values of pressure, velocity, and WSS at each fluid point in the domain at a specific cardiac timepoint. This difference in relative L2 norm captures the energy-normalized Euclidean distance between the reference and ground-truth waveforms and is suitable for time-dependent convergence involving millions of fluid and shell points9,56. In this study, the relative L2 difference was evaluated at three physiologically important cardiac phases: ventricular end-diastole (TED), corresponding to the completion of ventricular filling; end-systole (TES), marking the end of ventricular ejection; and end of the cardiac cycle (TEnd), representing a full beat-to-beat transition. Both the domain-averaged and maximum (98th percentile) values of the relative L2 difference were examined to capture overall and peak deviations. A 5% threshold is commonly used in cardiovascular CFD studies as a clinically relevant standard for convergence57–59. To support stricter convergence assessment without significantly increasing computational cost, we adopted a 2% threshold60,61 for percent difference and an equivalent L2 norm of 0.0262 which provides a practical balance between physiological accuracy and simulation efficiency for dynamic-state modeling.

E. Methodological framework for evaluating convergence under dynamic heart rate transitions

To assess the temporal convergence of simulated hemodynamics in dynamic conditions, we developed a systematic framework leveraging both real-world and synthetic heart rate (HR) transitions. For each heartbeat or region of interest (ROI) within a wearable-derived HR sequence, a pulsatile inlet velocity waveform was generated by scaling a reference waveform from the literature, as described in Section IIB. To analyze the hemodynamic behavior in the stenosed LAD artery, three axial cross-sections were selected downstream of the ostium (used as the reference point for PG calculations): (1) immediately post-stenosis, (2) post-stenotic recovery region, and (3) a distal, near-outlet locations (Figure 1A). These locations were chosen for consistency across all patient-specific geometries and represent regions of high clinical and hemodynamic relevance..

FIG. 1.

FIG. 1.

Overview of the methodological framework for assessing temporal convergence in coronary simulations under heart rate (HR) transitions. (A) Inlet waveforms are scaled from literature using wearable-derived heart rate data and applied to patient-specific coronary geometries. All patients have stenosed left anterior descending artery (LAD) where three arterial slice locations were specified distal to the 1. ostium (reference point for PG) slice namely - 2. immediately after stenosis, 3. post-stenosis, and 4. near-outlet. (B) For each heartbeat of interest, simulations with varying pre-flows (Npre) are compared to a ground-truth (GT) (Npre=5) on the heartbeat or region of interest (ROI) selected from any real-world HR sequence to assess convergence. (C) Two extreme HR transitions: 200→50 bpm and 50→200 bpm – are modeled to bracket dynamic fluctuations in HR sequence.

Given a continuous HR time series, the primary objective was to determine the number of preceding cardiac cycles (denoted as Npre) required for the simulated hemodynamics to converge within the region of interest. For each selected ROI, simulations were repeated using increasing values of Npre=1,2,3,…, and compared against a ground-truth (GT) simulation using Npre=5 (Figure 1B)1. While convergence may occur in fewer than five cycles for some metrics, we selected Npre=5 as a conservative standard to ensure robust GT across all anatomical models and hemodynamic variables32,63,64. This choice is consistent with our prior workflow, where five pre-flow cycles were used to define convergence in patient-specific CFD simulations1,30,31. All three hemodynamics parameters were analyzed on the region of interest (ROI) between the reference and GT waveforms.

To ensure generalizability across a wide physiological spectrum, we modeled two extreme HR transitions: high-to-low (200 to 50 bpm) and low-to-high (50 to 200 bpm), representing the full range of resting and exertional HRs observed in population-scale studies65,66 (Figure 1C). These scenarios bracket real-world variability and allow robust evaluation of temporal convergence in dynamic HR conditions.

F. Approach for assessing convergence under HR transitions

To systematically evaluate convergence behavior in dynamically evolving HR conditions, we developed a simulation approach to address two key questions: (i) how many cardiac cycles upstream of a rapid HR shift influence the ROI? (ii) for each such scenario, how many preceding cardiac cycles (pre-flows, Npre) are required to achieve convergence.

For each HR transition scenario of high-to-low and low-to-high – we systematically varied the timing of the HR shift relative to the ROI. The shift timing was defined as the number of beats before the ROI at which the HR change occurred. For example, a shift occurring one beat before the ROI is expressed as:

ShiftTiming:shift=ROI-n (13)

This process is depicted in Figure 2, and the low-to-high case in Figure 3, each illustrating the shift construction and waveform comparison approach used to assess convergence.

FIG. 2.

FIG. 2.

Construction of subcases for the high-to-low heart rate transition (200 to 50 bpm). Regions of interest (ROI) are selected after the shift at beats ROI–1, ROI–2, ROI-3, …, ROI-n, and each ROI is compared with varying numbers of pre-flows (Npre=1,2,..) to a ground-truth simulation (Npre=5) to evaluate convergence.

FIG. 3.

FIG. 3.

Setup of subcases for the low-to-high heart rate transition (50 to 200 bpm). Each region of interest (ROI) beat is chosen post-transition (shift = ROI-1, ROI–2, ROI–3,…., ROI-n) and simulated with an increasing number of pre-flows (Npre=1,2,..). Convergence is assessed relative to a ground-truth waveform using Npre=5.

For each value of n, we compared the corresponding ROI waveforms (e.g., n = 1 vs n = 2) to identify the temporal extent to which upstream HR shifts continue to affect downstream hemodynamics. This approach established the number of meaningful subcases required to capture the influence of HR transitions.

Within each identified subcase, we then varied the number of pre-flows (Npre=1,2,3,…) and compared the resulting hemodynamic waveforms to a GT simulation with Npre=5. This analysis allowed us to determine the minimum number of pre-flows necessary to eliminate transient effects and achieve physiologically accurate hemodynamic predictions at the ROI.

III. RESULTS AND DISCUSSION

A. Heart rate transitions influence hemodynamics for up to two cardiac cycles

We evaluated the impact of upstream HR transitions on hemodynamics by comparing ROIs’s where shifts occur between one and four cardiac cycles (n = 1 to 4) prior to ROI. As shown in Figures 4 and 5, HR changes occurring within two beats prior to the ROI significantly influenced PG, velocity, and WSS, whereas shifts three or more beats upstream had negligible effects. This trend was consistent for both high-to-low and low-to-high transitions, supporting a two-beat temporal window for convergence assessment.

FIG. 4.

FIG. 4.

Percent difference in hemodynamic metrics across LAD cross-sectional slices under dynamic heart rate transitions in post-shift regions. (A) High-to-low HR transitions with comparisons between successive regions of interest (ROIs) where shift occurs at: (a) ROI–1 vs ROI–2, (b) ROI–2 vs ROI–3, and (c) ROI–3 vs ROI–4. (B) Comparison of ROI’s for low-to-high HR transitions with shifts at (d) ROI–1 vs ROI–2, (e) ROI–2 vs ROI–3, and (f) ROI–3 vs ROI–4. Percent differences in pressure gradient (PG), velocity, and wall shear stress (WSS) are computed at key LAD locations: post-stenosis, recovery region, and near-outlet. Both transitions had 5 pre-flows in pre-shift region for stable comparison. Convergence is evaluated using a 2% threshold and panels with red shading indicate comparisons exceeding the threshold, while green indicates convergence within the accepted tolerance

FIG. 5.

FIG. 5.

Relative L2 difference analysis averaged over the full 3D coronary domain in post-shift regions at three cardiac timepoints: end-diastole (TED), end-systole(TES), and end of cycle (TEnd). (A) High-to-low HR transitions, comparing successive ROI’s with shifts at (a) ROI–1 vs ROI–2, (b) ROI–2 vs ROI–3, (c) ROI–2 vs ROI–3. (B) Low-to-high HR transitions with shifts (ROI-n) at (d) ROI–1 vs ROI–2, (e) ROI–2 vs ROI–3, (f) ROI–2 vs ROI–3. Convergence is assessed using an L2 threshold of 0.02 for pressure, velocity, and wall shear stress (WSS) and both transitions had 5 pre-flows in pre-shift region for stable comparison. Red-shaded panels indicate differences exceeding tolerance; green panels indicate converged results

1. Percent difference in cross-sectional hemodynamics is highest immediately after transition

Figure 4 presents the percent differences in average PG, velocity and WSS at three locations along the LAD stenosis, post stenosis, and near the outlet, comparing ROIs generated from HR shifts occuring n beats before the ROI. For both cases A and B, with 5 cardiac cycles are there prior to an extreme shift, we observe that when the HR shift occurs one beat before ROI (n = 1), the percent difference relative to n = 2 exceeds the 2% threshold at multiple locations. This trend is especially pronounced in the velocity and the WSS. WSS is highly sensitive to transient flow characteristics and is known to reflect shear-driven endothelial responses30,67,68. Notably, as the HR shift moves further away from the ROI (i.e., n = 2 vs n = 3 and n = 3 vs n = 4), percent differences drop below the 2% threshold in all measured locations. This finding supports the conclusion that HR changes that occur within two beats prior to ROI (that is, n ≤ 2) can significantly influence local hemodynamics, while shifts further upstream (n>2) have minimal impact, effectively decoupling ROI from earlier dynamic transitions.

2. L2 domain difference shows flow stabilization by two beats after HR shift

Relative L2 difference (Figure 5) was averaged over full 3D domain at three cardiac timepoints – TED, TES, and TEnd, comparing ROI’s with n vs n + 1 for n = 1 to 3, where shift = ROI - n. For both transition cases, L2 difference values remain below the 0.02 threshold for ROI’s with n= 2 vs n= 3 and n= 3 vs n = 4 across all timepoints. However, in the ROI’s with n = 1 vs n = 2 comparisons, TED exhibits noticeable deviations above the threshold for multiple parameters, while TES and TEnd remain more stable.

Together with the slice-wise results, 3D domain analysis confirms that an upstream HR shift as early as two beats before the ROI (n = 2) is sufficient for achieving convergence across both localized and whole-domain hemodynamic metrics. This observation underscores the importance of pairing domain-level analysis with localized assessments to fully capture convergence behavior under dynamic conditions. Similar findings were observed when maximum (98th percentile) L2 differences were computed (shown in Supplementary Figure S1).

3. WSS deviations localize near stenosis and curvature

To resolve fine-grained hemodynamic differences induced by HR transitions, we examined absolute WSS differences in points throughout the coronary wall (Figure 6). In the high-to-low case (panel A), the n = 1 vs n = 2 comparison reveals widespread WSS deviations, with localized peaks exceeding 1.7 × 10−3 Pa near the stenotic region. However, the n = 2 vs n = 3 comparison shows a marked attenuation in spatial difference, with most differences falling below 1.1 × 10−4 Pa.

FIG. 6.

FIG. 6.

3D point-to-point differences in WSS across cardiac cycles for a representative patient geometry at end-diastole timepoint. (A) In the high-to-low HR transition, WSS differences decrease markedly from (a) n = 1 vs. n = 2 to (b) n = 2 vs. n = 3 when shift occurs at ROI-n. (B) Similarly, in the low-to-high HR transition, WSS differences diminish substantially from (c) n = 1 vs. n = 2 to (d) n = 2 vs. n = 3 when shift occurs at ROI-n. These spatial comparisons highlight the rapid stabilization of WSS following HR shifts, supporting the use of two pre-flows for achieving physiologically consistent simulations. Red and green shaded areas indicate converged and unconverged beats, respectively

A similar trend is observed in the low-to-high case (panel B), where the WSS differences for n= 1 vs. n= 2 reach 3.3 × 10−4 Pa, particularly near bifurcations and curved segments. These differences drop significantly in the comparison n = 2 vs. n = 3, with maximal deviations below 5.1 × 10−5 Pa.

These spatial patterns reinforce the conclusion that HR shifts occurring more than two beats upstream produce minimal residual influence on WSS. In particular, the peak differences in WSS align with areas of high curvature and stenosis, where flow instabilities are most sensitive to upstream perturbations. This finding further supports the two-beat stabilization window to ensure convergence in wall-dependent biomarkers essential for clinical relevance.

B. Two pre-flows are sufficient to ensure convergence at ROI across hemodynamic metrics

Temporal convergence was affected not only by the position of the HR shift, but also by the number of cardiac cycles simulated before. We analyzed within two pre-flows (Npre=2), the parameters converged across two subcases (n=1 and 2) for each of the two dynamic shift scenarios.

1. 1–2 pre-flows ensure convergence at LAD cross-sections depending on transition type

Table I demonstrates for high-to-low transitions, both ROI beats with shifts at n = 1 and n = 2 achieved convergence with Npre=1 across all parameters, with percent differences remaining below 2%. This behavior is consistent across all three slice locations for these two ROIs highlights the robustness of early convergence in decelerated HR conditions. On the other hand, for low-to-high transitions, velocity and WSS required Npre=2 to drop below the threshold. The elevated sensitivity to shifts occurring towards higher heart rate transition reflects the heightened inertia and transient development in flow structures. The trend of decreasing percent differences with increasing number of pre-flows for all cases have been showed in Supplementary Figure S2.

TABLE I.

Required Npre for convergence across slice locations (a= post-stenotic, b= recovery region, and c= near outlet) and HR transitions at 2% tolerance.

Location High-to-Low shift Low-to-High shift
ROI-1 ROI-2 ROI-1 ROI-2

PG V WSS PG V WSS PG V WSS PG V WSS
a <1 1 1 <1 1 1 <1 2 2 <1 2 2
b <1 1 1 <1 1 1 <1 2 2 <1 1 1
c <1 1 1 <1 1 1 <1 1 2 <1 1 1

PG = Pressure Gradient, V = Velocity, WSS = Wall Shear Stress.

2. Whole-domain relative L2 difference confirms need for two pre-flows in delayed ROIs

The relative L2 difference trends in Figure 7 reinforce the slice-wise results. For both types of transition, the ROI beats immediately after HR shift (n = 1) converged with Npre=1 in the TED, TES, and TEnd phases. However, for ROI beats located two cycles after the shift (n = 2), convergence in WSS and velocity required Npre=2. Notably, the relative L2 dropped from above the 0.02 threshold at Npre=1 to well below it at Npre=2, suggesting the necessity of additional upstream flow cycles to fully resolve transient flow evolution in those delayed cases. In several cases, the difference in relative L2 norm exceeded 0.02 for WSS at Npre=1 (e.g., TES phase in panel D and F), highlighting the persistence of upstream transient effects. At Npre=2, all differences consistently dropped below the threshold in all phases and metrics. This consistency reinforces the need for two pre-flows when simulating hemodynamic states not immediately influenced by the HR shift, where residual transients persist over multiple cycles. Comparable trends were also observed when evaluating the maximum (98th percentile) relative L2 differences for this analysis, as presented in Supplementary Figure S3.

FIG. 7.

FIG. 7.

Influence of number of pre-flows (Npre) on temporal convergence averaged over full 3D domain. (A,B) High-to-low subcases with HR shifts at ROI-1 and ROI-2. (C,D) Low-to-high subcases with HR shifts at ROI-1 and ROI-2. For each case, results are shown for Npre=1 (a, c, e, g) and Npre=2 (b, d, f, h) across three cardiac timepoints: end-diastole (TED), end-systole(TES), and end of cycle (TEnd) with respect to the ground-truth of Npre=5. Relative L2 differences are averaged across all patients, highlighting the improved convergence achieved with two pre-flows under both transition types. Purple and orange shaded panels indicate shifts at ROI-1 and ROI-2, respectively.

3. Pointwise WSS differences drop sharply with second pre-flow

Figures 8 and 9 provide pointwise maps of WSS differences for n = 2 ROIs. In the high-to-low case (Figure 8), WSS differences at Npre=1 ranged from 5.4 to 16.8 Pa, with high gradients observed near the bifurcation and along the lesion boundary. With Npre=2, the differences reduced dramatically, falling within 0.092 to 3.9 × 10−4 Pa, especially at end-diastolic and end-systolic phases.

FIG. 8.

FIG. 8.

Point-to-point differences in WSS magnitude for a representative patient geometry under a high-to-low HR transition. Results compare simulations using (A) Npre=1 and (B) Npre=2 against the ground truth (Npre=5). Contour maps illustrate spatial differences at three cardiac timepoints: end-diastole:(TED) (a,d), end-systole: (TES) (b,e), and end-of-cycle: (TEnd) (c,f). The reduction in WSS discrepancies with Npre=2 demonstrates improved convergence following HR transitions.

FIG. 9.

FIG. 9.

Point-to-point differences in WSS magnitude for a representative patient geometry under a low-to-high HR transition. Simulations with (A) Npre=1 and (B) Npre=2 are compared to the ground truth (Npre=5). Contour maps show WSS differences at three cardiac timepoints: end-diastole:(TED) (a,d), end-systole: (TES) (b,e), and end-of-cycle: (TEnd) (c,f). The reduction in WSS discrepancies with Npre=2 indicates improved spatial convergence following accelerated heart rate transitions.

Similarly, for the low-to-high case (Figure 9), regions of high WSS variation at Npre=1, extending from mid-vessel to distal segments showed absolute differences up to 16.8 Pa. At Npre=2, spatial differences fell below 1.0 Pa in most regions, and below 0.4 Pa in distal LAD. These spatial reductions confirm that two pre-flows are sufficient for achieving physiological convergence across the vascular wall, even under abrupt HR transition conditions. Importantly, this behavior was phase-consistent, confirming that the observed convergence is not only spatial but also temporally uniform across the cardiac cycle. These reductions in near-wall stress support the selection of Npre=2 as a physiologically justified standard for minimizing transient effects and ensuring convergence.

This analysis highlights that while one pre-flow may suffice for immediate post-transition states, a second pre-flow becomes necessary to resolve hemodynamic stability in slightly delayed regions of interest. This threshold ensures both global and localized convergence and provides a practical guideline for improving efficiency in dynamic cardiovascular digital twin simulations.

C. Real-world HR data confirms generalizability of two pre-flow Npre=2 condition

Having established that Npre=2 ensures convergence across various synthetic HR shift scenarios, we sought to verify this conclusion using real-world HR data as shown in Figure 10A and Figure 10B. From a continuous one-hour sequence of HR data, two distinct 10-beat segments corresponding to the lowest and highest recorded HR values were extracted (Figure 10(a) and (b)). Specifically, the wearable-derived HR data included a resting segment with a global minimum HR of 48 bpm (Figure 10(c)) and a high-HR segment with a peak HR of 192 bpm (Figure 10(d)). These selections represent natural extrema in HR variability and allowed us to test Npre=2 under representative edge-case dynamic inputs on one of the representative LCA geometries.

FIG. 10.

FIG. 10.

Verification of two pre-flows (Npre=2) using real-world HR sequences during (A) low-HR and (B) high-HR segments. Continuous HR data were analyzed over one-hour periods, with (a) low-HR and (b) high-HR segments identified. Ten consecutive heartbeats with extreme HRs were selected: (c) minimum HR of 48 bpm during the low-HR segment and (d) maximum HR of 192 bpm during the high-HR segment. Temporal convergence was confirmed with Npre=2 for PG, velocity, and WSS at the stenotic LAD location in a representative patient geometry for both (e) low-HR and (f) high-HR conditions.

Figures 10 (e) and (f) show the HR traces and the corresponding percentage difference values for each beat in the two selected HR segments. For the low-HR segment (panel e), HRs remained relatively stable with slight variability between beats. For all 10 beats tested at Npre=2, the percent difference in average PG, velocity, and WSS at the stenosed LAD slice remained below 2%. Similarly, for the high-HR segment (panel f), where HR varied more dramatically between successive beats, all beats achieved convergence with Npre=2 in all hemodynamic parameters at the stenotic location.

The percent difference values remained consistently below 2% for both HR segments, indicating whole-domain convergence. The fact that percent differences remained below the threshold despite modeling only heart rate–driven fluctuations, derived from wearable input data, demonstrates the robustness of using two pre-flows for convergence even under highly dynamic, real-life HR conditions. Importantly, convergence was observed consistently across all 10 heartbeats in each case, without requiring a beat-specific tuning of Npre. This result suggests that Npre=2 may serve as a generally applicable convergence guideline for dynamic digital twin simulations incorporating real-time wearable HR data.

Together, these findings provide strong verification for our earlier results and support the feasibility of using Npre=2 as a standard for convergence assessment in both synthetic and wearable-informed digital twin models.

IV. LIMITATIONS AND FUTURE WORK

This study employed constant outlet boundary conditions to isolate the effects of upstream HR transitions on temporal convergence. Although this simplification allowed for standardized comparisons, it does not reflect physiologic variability in coronary microcirculation or downstream autoregulatory effects. Previous work has shown that distal resistance variation significantly affects coronary perfusion under exercise and pharmacological stress69–71.

Future work should incorporate time-varying or patient-specific outlet models to capture autoregulatory behavior and enhance the realism of dynamic-state simulations. Incorporating these physiological responses will enable more accurate predictions of coronary hemodynamics during activity-induced transitions and further enhance the clinical relevance of coronary digital twins.

V. CONCLUSION

This study presents a systematic and physiologically grounded investigation into temporal convergence in patient-specific coronary simulations under dynamic HR conditions. We addressed two fundamental questions: (1) how far upstream an HR transition can influence hemodynamics in a downstream ROI, and (2) how many preceding cardiac cycles (Npre) are required to achieve convergence in key hemodynamic outputs. To evaluate worst-case scenarios, we modeled extreme HR transitions – from high to low (200 to 50 bpm) and low to high (50 to 200 bpm), using high-resolution 3D CFD simulations across anatomically diverse, patient-specific coronary geometries. Our findings show that abrupt changes in HR can affect downstream hemodynamics for up to two cardiac cycles. Simulating two pre-flows (Npre=2) was consistently sufficient to ensure convergence of pressure distribution, velocity, and WSS, both in cross-sectional slices and across the full 3D vascular domain. Notably, velocity and WSS were more sensitive to transient upstream conditions, especially near regions of stenosis and high curvature, while pressure distributions stabilized more quickly.

These trends were maintained in all synthetic HR transition cases and further verified using real-world HR sequences derived from wearable devices capturing naturally occurring low and high HR segments. Across all conditions, a two-beat initialization window provided physiologically stable and computationally consistent outputs without requiring manual tuning of simulation parameters.

Together, this work establishes a robust, verified, and generalizable framework to ensure temporal convergence in dynamic-state cardiovascular digital twins. This capability is particularly important for longitudinal disease surveillance, where digital twins are continuously updated using real-time sensing data. By ensuring convergence during transitions across physiological states, the proposed framework supports an accurate assessment of hemodynamic changes over time, improving the reliability of digital twin–based predictions in scenarios such as monitoring in-stent restenosis progression or evaluating treatment efficacy during stress tests. By defining Npre=2 as a physiologically justified default, the study lays the foundation for a wearable-informed real-time modeling of coronary blood flow, allowing a greater adoption of digital twin technologies in clinical and remote monitoring applications.

Supplementary Material

Supplemental

See the supplementary material for Supplementary Table S1: Patient-specific clinical and geometric information; Supplementary Table S2:Patient-specific inputs for Windkessel parameterization; Supplementary Fig S1: Maximum (98th percentile) relative L2 difference analysis across full 3D coronary domain at three cardiac timepoints; Supplementary Fig S2: Determining number of pre-flows (Npre) required for temporal convergence in high-to-low and low-to-high HR transitions, based on patient-averaged data; Supplementary Fig S3: Influence of number of pre-flows (Npre) on temporal convergence with maximum (98th percentile) L2 difference taken over full 3D domain.

ACKNOWLEDGMENTS

The authors thank Dr. Arash Ghorbannia, William Ladd, Samreen Mahmud, and Dr. Benjamin Hezrony for their feedback and discussion. Research reported in this publication was supported by the National Institute On Aging of the National Institutes of Health under Award Number DP1AG082343. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health. Computing support for this work came from the Duke Compute Cluster.

NOMENCLATURE

BGK

Bhatnagar–Gross–Krook

CFD

Computational fluid dynamics

FFR

Fractional flow reserve

HR

Heart rate

LAD

Left anterior descending artery

LBM

Lattice Boltzmann

LCA

Left coronary artery

PG

Pressure gradient

ROI

Region of interest

TED

Ventricular end-diastole time point

TEnd

End of cardiac cycle time point

TES

Ventricular end-systole time point

WSS

Wall shear stress

Aostial

Coronary ostial area

α

Coronary flow fraction

cα

Discrete lattice velocity vector

cs

Lattice speed of sound

C

Compliance

n

Outward wall unit normal

τ

Wall shear stress vector

τcardiac

Cardiac period

fαneq

Non-equilibrium LBM particle distribution

HRbaseline

Baseline (resting) heart rate

HRinstant

Instantaneous (dynamic) heart rate

μ

Dynamic viscosity of blood

μ0

Plasma viscosity n: Beat number in upstream shift

n

Beat number in upstream shift

Npre

Number of pre-flow cycles

Pa, Pd

Proximal (ostial/aortic) and distal pressures

ϕ

Hematocrit

Q

Volumetric flow rate

Qbaseline

Baseline coronary flow rate

QSV

Stroke volume

Rp

Peripheral (outlet) resistance

ρ

Density of blood

vmax

Maximum inlet velocity

Footnotes

Conflict of Interest

The authors have no conflicts to disclose.

DATA AVAILABILITY

The data that support the findings of this study are available from the corresponding author upon reasonable request.

REFERENCES

  • 1.Vardhan M, Gounley J, Chen SJ, Chi EC, Kahn AM, Leopold JA, and Randles A, “Non-invasive characterization of complex coronary lesions,” Scientific reports 11, 1–15 (2021), publisher: Springer. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Xie X, Li N, Yu T, Pu W, Lin H, Li X, Li G, Li C, Chen Y, and Lian K, “Validation of a novel computational fluid dynamics based method for assessing intracoronary flow: Combining coronary angiography and fractional flow reserve,” Catheterization and Cardiovascular Interventions (2025). [DOI] [PubMed] [Google Scholar]
  • 3.Ho NN, Lee KY, and Lee S-W, “Uncertainty quantification of computational fluid dynamics-based predictions for fractional flow reserve and wall shear stress of the idealized stenotic coronary,” Frontiers in Cardiovascular Medicine 10, 1164345 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Vignon-Clementel I, Figueroa C, Jansen K, and Taylor C, “Outflow boundary conditions for 3D simulations of non-periodic blood flow and pressure fields in deformable arteries,” Computer Methods in Biomechanics and Biomedical Engineering 13, 625–640 (2010), publisher: Taylor & Francis _eprint: 10.1080/10255840903413565. [DOI] [PubMed] [Google Scholar]
  • 5.Vardhan M, Tanade C, Chen SJ, Mahmood O, Chakravartti J, Jones WS, Kahn AM, Vemulapalli S, Patel M, Leopold JA, et al. , “Diagnostic performance of coronary angiography derived computational fractional flow reserve,” Journal of the American Heart Association 13, e029941 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Taylor CA, Petersen K, Xiao N, Sinclair M, Bai Y, Lynch SR, UpdePac A, and Schaap M, “Patient-specific modeling of blood flow in the coronary arteries,” Computer Methods in Applied Mechanics and Engineering 417, 116414 (2023). [Google Scholar]
  • 7.Gaur S, Achenbach S, Leipsic J, Mauri L, Bezerra HG, Jensen JM, Bøtker HE, Lassen JF, and Nørgaard BL, “Rationale and design of the heartflownxt (heartflow analysis of coronary blood flow using ct angiography: Next steps) study,” Journal of cardiovascular computed tomography 7, 279–288 (2013). [DOI] [PubMed] [Google Scholar]
  • 8.Nørgaard BL, Leipsic J, Gaur S, Seneviratne S, Ko BS, Ito H, Jensen JM, Mauri L, De Bruyne B, Bezerra H, et al. , “Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in suspected coronary artery disease: the nxt trial (analysis of coronary blood flow using ct angiography: Next steps),” Journal of the American College of Cardiology 63, 1145–1155 (2014). [DOI] [PubMed] [Google Scholar]
  • 9.Khalili E, Daversin-Catty C, Olivares AL, Mill J, Camara O, and Valen-Sendstad K, “On the importance of fundamental computational fluid dynamics toward a robust and reliable model of left atrial flows,” International Journal for Numerical Methods in Biomedical Engineering 40, e3804 (2024). [DOI] [PubMed] [Google Scholar]
  • 10.Mittal R, Seo JH, Vedula V, Choi YJ, Liu H, Huang HH, Jain S, Younes L, Abraham T, and George RT, “Computational modeling of cardiac hemodynamics: Current status and future outlook,” Journal of Computational Physics 305, 1065–1082 (2016). [Google Scholar]
  • 11.Arbia G, Corsini C, Moghadam ME, Marsden AL, Migliavacca F, Pennati G, Hsia T-Y, Vignon-Clementel IE, Investigators MOCHAM, et al. , “Numerical blood flow simulation in surgical corrections: what do we need for an accurate analysis?” Journal of Surgical Research 186, 44–55 (2014). [DOI] [PubMed] [Google Scholar]
  • 12.National Academies of Sciences, Engineering, and Medicine et al. , “Foundational research gaps and future directions for digital twins (2024),”. [PubMed]
  • 13.National Academy of Sciences, Engineering, and Medicine et al. , “Foundational research gaps and future directions for digital twins,” (2024). [PubMed]
  • 14.Malota Z, Glowacki J, Sadowski W, and Kostur M, “Numerical analysis of the impact of flow rate, heart rate, vessel geometry, and degree of stenosis on coronary hemodynamic indices,” BMC Cardiovascular Disorders 18, 132 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Hughes A, Shandhi MMH, Master H, Dunn J, and Brittain E, “Wearable devices in cardiovascular medicine,” Circulation research 132, 652–670 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Köhler C, Bartschke A, Fürstenau D, Schaaf T, and Salgado-Baez E, “The value of smartwatches in the health care sector for monitoring, nudging, and predicting: Viewpoint on 25 years of research,” Journal of Medical Internet Research 26, e58936 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Ming DK, Sangkaew S, Chanh HQ, Nhat PT, Yacoub S, Georgiou P, and Holmes AH, “Continuous physiological monitoring using wearable technology to inform individual management of infectious diseases, public health and outbreak responses,” International Journal of Infectious Diseases 96, 648–654 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Vallée A, “Envisioning the future of personalized medicine: Role and realities of digital twins,” Journal of Medical Internet Research 26, e50204 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Sel K, Osman D, Zare F, Masoumi Shahrbabak S, Brattain L, Hahn J-O, Inan OT, Mukkamala R, Palmer J, Paydarfar D, et al. , “Building digital twins for cardiovascular health: from principles to clinical impact,” Journal of the American Heart Association 13, e031981 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Katsoulakis E, Wang Q, Wu H, Shahriyari L, Fletcher R, Liu J, Achenie L, Liu H, Jackson P, Xiao Y, et al. , “Digital twins for health: a scoping review,” NPJ digital medicine 7, 77 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Papachristou K, Katsakiori PF, Papadimitroulas P, Strigari L, and Kagadis GC, “Digital twins’ advancements and applications in healthcare, towards precision medicine,” Journal of Personalized Medicine 14, 1101 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Li X, Loscalzo J, Mahmud AF, Aly DM, Rzhetsky A, Zitnik M, and Benson M, “Digital twins as global learning health and disease models for preventive and personalized medicine,” Genome Medicine 17, 11 (2025). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Grande Gutiérrez N, Alber M, Kahn AM, Burns JC, Mathew M, McCrindle BW, and Marsden AL, “Computational modeling of blood component transport related to coronary artery thrombosis in kawasaki disease,” PLoS computational biology 17, e1009331 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Rajani R, Modi B, Ntalas I, and Curzen N, “Non-invasive fractional flow reserve using computed tomographic angiography: where are we now and where are we going?” Heart 103, 1216–1222 (2017). [DOI] [PubMed] [Google Scholar]
  • 25.Sankaran S, Lesage D, Tombropoulos R, Xiao N, Kim HJ, Spain D, Schaap M, and Taylor CA, “Physics driven real-time blood flow simulations,” Computer Methods in Applied Mechanics and Engineering 364, 112963 (2020). [Google Scholar]
  • 26.Tanade C and Randles A, “Harvi: Real-time intervention planning for coronary artery disease using machine learning,” in International Conference on Computational Science (Springer, 2024) pp. 48–62. [Google Scholar]
  • 27.Tanade C and Randles A, “Real-time virtual intervention for simple and serial coronary artery disease using the harvi framework,” Journal of Computational Science 87, 102570 (2025). [Google Scholar]
  • 28.Chaniotis A, Kaiktsis L, Katritsis D, Efstathopoulos E, Pantos I, and Marmarellis V, “Computational study of pulsatile blood flow in prototype vessel geometries of coronary segments,” Physica Medica 26, 140–156 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Toloui M, Nikparto A, Firoozabadi B, and Saidi MS, “Numerical simulations of haemodynamic factors and hyperelastic circumferential strain/stress in the ideal and healthy-patient-specific carotid bifurcations for different rheological models,” International Journal of Biomedical Engineering and Technology 6, 387–412 (2011). [Google Scholar]
  • 30.Tanade C, Rakestraw E, Ladd W, Draeger E, and Randles A, “Cloud Computing to Enable Wearable-Driven Longitudinal Hemodynamic Maps,” in Proceedings of the International Conference for High Performance Computing, Networking, Storage and Analysis, SC ’23 (Association for Computing Machinery, New York, NY, USA, 2023) pp. 1–14. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 31.Tanade C, Khan NS, Rakestraw E, Ladd W, Draeger EW, and Randles A, “Establishing the longitudinal hemodynamic mapping framework for wearable-driven coronary digital twins,” npj Digital Medicine (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Pfaller MR, Pham J, Wilson NM, Parker DW, and Marsden AL, “On the Periodicity of Cardiovascular Fluid Dynamics Simulations,” Annals of Biomedical Engineering 49, 3574–3592 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Vardhan M, Gounley J, Chen SJ, Kahn AM, Leopold JA, and Randles A, “The importance of side branches in modeling 3D hemodynamics from angiograms for patients with coronary artery disease,” Scientific reports 9, 1–10 (2019), publisher: Springer. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 34.Mirramezani M, Diamond SL, Litt HI, and Shadden SC, “Reduced Order Models for Transstenotic Pressure Drop in the Coronary Arteries,” Journal of Biomechanical Engineering 141 (2019), 10.1115/1.4042184. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Madhavan S and Kemmerling EMC, “The effect of inlet and outlet boundary conditions in image-based CFD modeling of aortic flow,” BioMedical Engineering OnLine 17, 66 (2018). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Les AS, Shadden SC, Figueroa CA, Park JM, Tedesco MM, Herfkens RJ, Dalman RL, and Taylor CA, en“Quantification of Hemodynamics in Abdominal Aortic Aneurysms During Rest and Exercise Using Magnetic Resonance Imaging and Computational Fluid Dynamics,” Annals of Biomedical Engineering 38, 1288–1313 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Gamilov T, Kopylov P, and Simakov S, en“Computational Simulations of Fractional Flow Reserve Variability,” in enNumerical Mathematics and Advanced Applications ENUMATH 2015, Lecture Notes in Computational Science and Engineering, edited by Karasözen B, Manguoğlu M, Tezer-Sezgin M, Göktepe S, and Uğur (Springer International Publishing, Cham, 2016) pp. 499–507. [Google Scholar]
  • 38.Furberg R, Brinton J, Keating M, and Ortiz A, “Crowd-sourced Fitbit datasets 03.12.2016–05.12.2016,” (2016), 10.5281/zenodo.53894. [DOI] [Google Scholar]
  • 39.Chen SJ and Carroll JD, “3-d reconstruction of coronary arterial tree to optimize angiographic visualization,” IEEE transactions on medical imaging 19, 318–336 (2000). [DOI] [PubMed] [Google Scholar]
  • 40.Green NE, Chen S-YJ, Hansgen AR, Messenger JC, Groves BM, and Carroll JD, “Angiographic views used for percutaneous coronary interventions: A three-dimensional analysis of physician-determined vs. computer-generated views,” Catheterization and Cardiovascular Interventions 64, 451–459 (2005). [DOI] [PubMed] [Google Scholar]
  • 41.Tanade C, Feiger B, Vardhan M, Chen SJ, Leopold JA, and Randles A, “Global sensitivity analysis for clinically validated 1d models of fractional flow reserve,” in 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) (IEEE, 2021) pp. 4395–4398. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 42.Randles AP, Kale V, Hammond J, Gropp W, and Kaxiras E, “Performance analysis of the lattice boltzmann model beyond navier-stokes,” in 2013 IEEE 27th International Symposium on Parallel and Distributed Processing (IEEE, 2013) pp. 1063–1074. [Google Scholar]
  • 43.Randles A, Draeger EW, Oppelstrup T, Krauss L, and Gunnels JA, “Massively parallel models of the human circulatory system,” in Proceedings of the International Conference for High Performance Computing, Networking, Storage and Analysis, SC ’15 (Association for Computing Machinery, New York, NY, USA, 2015) pp. 1–11. [Google Scholar]
  • 44.Latt J, Chopard B, Malaspinas O, Deville M, and Michler A, “Straight velocity boundaries in the lattice boltzmann method,” Physical Review E 77, 056703 (2008). [DOI] [PubMed] [Google Scholar]
  • 45.Pirofsky B et al. , “The determination of blood viscosity in man by a method based on poiseuille’s law,” The Journal of clinical investigation 32, 292–298 (1953). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 46.Hadjiloizou N, Davies JE, Malik IS, Aguado-Sierra J, Willson K, Foale RA, Parker KH, Hughes AD, Francis DP, and Mayet J, “Differences in cardiac microcirculatory wave patterns between the proximal left mainstem and proximal right coronary artery,” American Journal of Physiology-Heart and Circulatory Physiology 295, H1198–H1205 (2008). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 47.C. A. Taylor, T. A. Fonte, and J. K. Min, “Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve: scientific basis,” Journal of the American College of Cardiology 61, 2233–2241 (2013). [DOI] [PubMed] [Google Scholar]
  • 48.Wilson RF, Wyche K, Christensen BV, Zimmer S, and Laxson DD, “Effects of adenosine on human coronary arterial circulation.” Circulation 82, 1595–1606 (1990). [DOI] [PubMed] [Google Scholar]
  • 49.Jiang MX, Khan MO, Ghobrial J, Rogers IS, Pettersson GB, Blackstone EH, and Marsden AL, “Patient-specific fluid–structure simulations of anomalous aortic origin of right coronary arteries,” JTCVS techniques 13, 144–162 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 50.Hair J, Timmins L, El Sayed R, Samady H, and Oshinski J, “Effect of patient-specific coronary flow reserve values on the accuracy of mri-based virtual fractional flow reserve,” Frontiers in Cardiovascular Medicine 8, 663767 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 51.Mao Y and Zhang Y, “Coronaryhemodynamics: An automated simulation framework for coronary artery hemodynamics using openfoam,” arXiv preprint arXiv:2501.08340 (2025). [Google Scholar]
  • 52.Westerhof N, Lankhaar J-W, and Westerhof BE, “The arterial Windkessel,” Medical & Biological Engineering & Computing 47, 131–141 (2009). [DOI] [PubMed] [Google Scholar]
  • 53.Feiger B, Kochar A, Gounley J, Bonadonna D, Daneshmand M, and Randles A, “Determining the impacts of venoarterial extracorporeal membrane oxygenation on cerebral oxygenation using a one-dimensional blood flow simulator,” Journal of Biomechanics 104, 109707 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 54.Sharma P, Itu L, Zheng X, Kamen A, Bernhardt D, Suciu C, and Comaniciu D, “A framework for personalization of coronary flow computations during rest and hyperemia,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE, 2012) pp. 6665–6668. [DOI] [PubMed] [Google Scholar]
  • 55.Matyka M, Koza Z, and Mirosław Ł, “Wall orientation and shear stress in the lattice boltzmann model,” Computers & Fluids 73, 115–123 (2013). [Google Scholar]
  • 56.Zhang J, Brindise MC, Rothenberger S, Schnell S, Markl M, Saloner D, Rayz VL, and Vlachos PP, “4d flow mri pressure estimation using velocity measurement-error-based weighted least-squares,” IEEE transactions on medical imaging 39, 1668–1680 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 57.McGah PM, Leotta DF, Beach KW, and Aliseda A, “Effects of wall distensibility in hemodynamic simulations of an arteriovenous fistula,” Biomechanics and modeling in mechanobiology 13, 679–695 (2014). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 58.Valeti C, Sudhir B, and Patnaik B, “Influence of hemodynamics on a patient-specific middle cerebral artery bifurcating aneurysm: An fsi study,” in Conference on Fluid Mechanics and Fluid Power (Springer, 2023) pp. 615–627. [Google Scholar]
  • 59.Renaldo AC, Lane MR, Shapiro SR, Mobin F, Jordan JE, Williams TK, Neff LP, Gayzik FS, and Rahbar E, “Development of a computational fluid dynamic model to investigate the hemodynamic impact of reboa,” Frontiers in Physiology 13, 1005073 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 60.Nannini G, Saitta S, Mariani L, Maragna R, Baggiano A, Mushtaq S, Pontone G, and Redaelli A, “An automated and time-efficient framework for simulation of coronary blood flow under steady and pulsatile conditions,” Computer Methods and Programs in Biomedicine 257, 108415 (2024). [DOI] [PubMed] [Google Scholar]
  • 61.Sun L, Ding L, Li L, Yin N, Yang N, Zhang Y, Xing X, Zhang Z, and Dong C, “Hemodynamic characteristics of cardiovascular system in simulated zero and partial gravities based on cfd modeling and simulation,” Life 13, 407 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 62.Wang L, Chen Z, Xu Z, Yang Y, Wang Y, Zhu J, Guo X, Tang D, and Gu Z, “A new approach of using organ-on-a-chip and fluid–structure interaction modeling to investigate biomechanical characteristics in tissue-engineered blood vessels,” Frontiers in Physiology 14, 1210826 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 63.Azarnoosh J, Ghorbannia A, Ibrahim E-SH, Jurkiewicz H, Kalvin L, and LaDisa JF Jr, “Temporal evolution of mechanical stimuli from vascular remodeling in response to the severity and duration of aortic coarctation in a preclinical model,” Scientific Reports 13, 8352 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 64.Ellwein L, Samyn MM, Danduran M, Schindler-Ivens S, Liebham S, and LaDisa JF Jr, “Toward translating near-infrared spectroscopy oxygen saturation data for the non-invasive prediction of spatial and temporal hemodynamics during exercise,” Biomechanics and modeling in mechanobiology 16, 75–96 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 65.Avram R, Tison GH, Aschbacher K, Kuhar P, Vittinghoff E, Butzner M, Runge R, Wu N, Pletcher MJ, Marcus GM, et al. , “Real-world heart rate norms in the health eheart study,” NPJ digital medicine 2, 58 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 66.Lach J, Wiecha S, Śliż D, Price S, Zaborski M, Cieśliński I, Postuła M, Knechtle B, and Mamcarz A, “Hr max prediction based on age, body composition, fitness level, testing modality and sex in physically active population,” Frontiers in physiology 12, 695950 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 67.Cecchi E, Giglioli C, Valente S, Lazzeri C, Gensini GF, Abbate R, and Mannini L, “Role of hemodynamic shear stress in cardiovascular disease,” Atherosclerosis 214, 249–256 (2011). [DOI] [PubMed] [Google Scholar]
  • 68.Jiang J and Strother C, “Computational Fluid Dynamics Simulations of Intracranial Aneurysms at Varying Heart Rates: A “Patient-Specific” Study,” Journal of Biomechanical Engineering 131, 091001 (2009). [DOI] [PubMed] [Google Scholar]
  • 69.Munneke AG, Lumens J, Arts T, and Delhaas T, “A closed-loop modeling framework for cardiac-to-coronary coupling,” Frontiers in physiology 13, 830925 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 70.Yang H, Zhang J, Assi I, Nallamothu BK, Garikipati K, and Figueroa CA, “A multi-physics model of flow from coronary angiography: Insights into microvascular function,” arXiv preprint arXiv:2412.04798 (2024). [DOI] [PubMed] [Google Scholar]
  • 71.Geng Y, Wu X, Liu H, Zheng D, and Xia L, “Index of microcirculatory resistance: State-of-the-art and potential applications in computational simulation of coronary artery disease,” Journal of Zhejiang University-SCIENCE B 23, 123–140 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]