Abstract
BACKGROUND: Stroke distance, the systolic velocity integral of aortic blood flow, is a linear analogue of stroke volume; its product with heart rate is minute distance, analogous to cardiac output. OBJECTIVE: To investigate the feasibility of assessing cardiac output in children with a simple non-invasive Doppler ultrasound technique, and to determine the normal range of values. METHODS: Peak aortic blood velocity, stroke distance, and minute distance were measured through the suprasternal window in 166 children (mean age 9.6 years, range 2-14) using a portable non-imaging Doppler ultrasound instrument. RESULTS: The technique was well tolerated by all the children participating. Mean peak aortic blood velocity was 138 cm/s and was independent of age. Mean stroke distance was 31.8 cm and showed a small but significant increase with age; mean minute distance was 2490 cm and fell with age, as did heart rate. CONCLUSIONS: Suprasternal Doppler ultrasound measurement of stroke distance is a convenient, well tolerated, non-invasive technique for the assessment of cardiac output in children. The normal range of values during childhood has been established. The technique has great potential for assessing hypovolaemia in children.
Full text
PDF



Images in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Anderson I. D., Woodford M., de Dombal F. T., Irving M. Retrospective study of 1000 deaths from injury in England and Wales. Br Med J (Clin Res Ed) 1988 May 7;296(6632):1305–1308. doi: 10.1136/bmj.296.6632.1305. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Little R. A., Kirkman E., Driscoll P., Hanson J., Mackway-Jones K. Preventable deaths after injury: why are the traditional 'vital' signs poor indicators of blood loss? J Accid Emerg Med. 1995 Mar;12(1):1–14. doi: 10.1136/emj.12.1.1. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Mowat D. H., Haites N. E., Rawles J. M. Aortic blood velocity measurement in healthy adults using a simple ultrasound technique. Cardiovasc Res. 1983 Feb;17(2):75–80. doi: 10.1093/cvr/17.2.75. [DOI] [PubMed] [Google Scholar]
- Sammy I., Hanson J., James M. R. Cerebral oximetry and stroke distance: the future of emergency department monitoring? J Accid Emerg Med. 1996 Sep;13(5):313–315. doi: 10.1136/emj.13.5.313. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Towfiq B. A., Weir J., Rawles J. M. Effect of age and blood pressure on aortic size and stroke distance. Br Heart J. 1986 Jun;55(6):560–568. doi: 10.1136/hrt.55.6.560. [DOI] [PMC free article] [PubMed] [Google Scholar]