Skip to main content
Wiley Open Access Collection logoLink to Wiley Open Access Collection
. 2026 Apr 29;95(3):328–333. doi: 10.1111/cod.70177

Chromium and Cobalt in Used Leather Items: A Danish Market Survey

Mikkel Bak Jensen 1,2,✉, Christoffer Kursawe Larsen 1, Lichen Bruce Guan 3, Jonas F Hedberg 3,4, Yolanda S Hedberg 3,4, Claus Zachariae 2,5, Jeanne Duus Johansen 1,2
PMCID: PMC13441321  PMID: 42056680

ABSTRACT

Introduction

Leather is a recognised source of contact allergy to chromium (Cr). Cobalt (Co) has also been identified as a potential leather‐related allergen.

Objectives

To assess the presence and release of Cr and Co in used leather items available on the Danish secondhand market.

Methods

Thirty‐four used consumer leather items with expected direct skin contact during normal use were purchased from secondhand shops in Greater Copenhagen, Denmark. Cr and Co were measured using handheld X‐ray fluorescence (XRF). Cr(VI) was measured according to International Organization for Standardization (ISO) standard 17 075‐1 following pre‐conditioning with ISO 10195. Extractable Co was analysed using ISO 17072‐1 and inductively coupled plasma mass spectrometry.

Results

Cr(VI) was detected in 12/34 (35.3%) items, with an average concentration of 1.77 mg/kg (range: 0.52–4.16). Co was detected in 7/34 (20.6%) items, with an average concentration of 0.63 mg/kg (range: 0.33–1.44). Shoes accounted for most items with higher Cr(VI) concentrations.

Conclusion

Used leather items may contain measurable levels of Cr(VI) and Co. Secondhand leather represents a relevant exposure scenario that should be considered in future exposure assessments and regulatory discussions.

Keywords: allergic contact dermatitis, chromium, chromium dermatitis, cobalt, leather


Used leather items from the Danish second‐hand market frequently release chromium(VI) and, in some cases, cobalt. Some items exceed current EU limits, highlighting a persistent but underrecognised source of exposure in the circular economy that may contribute to ongoing contact allergy despite existing regulations.

graphic file with name COD-95-328-g001.jpg

1. Introduction

Chromium (Cr) is a known cause of allergic contact dermatitis. Leather is an important source of exposure, particularly from footwear [1, 2, 3]. Both trivalent Cr (Cr(III)) and hexavalent Cr (Cr(VI)) may be released from Cr‐tanned leather during use [4]. Cr(VI) is considered the most potent sensitiser [1, 4]. In 2015, a European Union (EU) restriction limited Cr(VI) in leather articles with skin contact to 3 mg/kg. A lower limit of 1 mg/kg has been proposed [5]. Cobalt (Co) may occur in leather as a component of dyes or finishing processes and has been suggested as a potential leather‐related allergen. Although evidence of Coin leather products is growing, few studies have systematically investigated the occurrence and quantity of Co released from such items [6, 7].

Despite the 2015 EU restriction, contact allergy to Cr remains frequent [2]. In a Danish cross‐sectional study of consecutively patch tested adults from 2016 to 2024, the prevalence of contact allergy to Cr was 2.1%, and trends were stable across years. Among clinically relevant cases, the most frequently reported sources were leather shoes and gloves [8]. A Danish market survey of newly imported leather items was published in 2024. Most items complied with the EU Cr(VI) limit, but Cr was frequently detected, and Co was measurable in a subset of samples. These findings raised questions about exposure from used leather items in the growing secondhand market. Used leather is a relevant exposure scenario. Such items may predate the EU restriction. Importantly, Cr(VI) in leather is not constant. Its formation and release can change over time and is influenced by storage and environmental conditions [9, 10].

The aim of this study was to investigate the presence and release of Cr and Co in used leather items.

2. Methods

2.1. Sample Collection

A convenience sample of used leather items was collected. All items were purchased secondhand in the Copenhagen area between February and March 2025, and the production date was unknown. Within each shop, items were selected to ensure a variation in product type and degree of wear.

Eligible items were consumer leather items with expected direct skin contact during normal use. Items were included when leather constituted the main material of the relevant surface. Items were excluded if the relevant contact surface was fully covered by a non‐leather layer.

Each item was assigned a unique identification number (ID) and categorised by product type (watch, wallet, belt, shoe), condition (lightly used, heavily worn), surface finish (matte, glossy, suede) and colour. Condition grading was based on visual inspection of the leather surface and edges. ‘Lightly used’ indicated limited visible wear with intact surface and minimal cracking or abrasions. ‘Heavily worn’ indicated clear signs of prolonged use, such as pronounced abrasions, cracking, peeling of finish, deformation or marked discoloration in high‐friction areas.

For laboratory analyses, detachable non‐leather components with no relevance to skin contact (e.g., metal buckles) were removed when feasible prior to cutting the leather. Leather was sampled from areas expected to have the most skin contact: the underside of watch straps and belts, the inner surfaces of wallets (e.g., fold areas) and the inner shoe areas in contact with the foot (e.g., lining or insole surface), when present.

2.2. Laboratory Analyses

Leather samples were first pre‐conditioned according to ISO 10195, which involves heat treatment of the dry leather at 80°C for 24 h [11]. ISO 10195 was used to avoid false‐negative results due to high relative humidities (> 35%) and to counter seasonal and inter‐laboratory effects of varying relative humidities. Immediately after that, Cr(VI) was analysed using the ISO 17075‐1 protocol [12]. In short, Cr(VI) was extracted from triplicate samples of leather in deaerated phosphate buffer (22.8 g/L K2HPO4‧3H2O) for 3 h, after which the solution and leather were separated. An ultraviolet–visible (UV–Vis) analysis was performed on calibration standards and the samples after reaction with 1,5‐diphenylcarbazide under acidic conditions (phosphoric acid) using an Agilent Cary 60 UV–Vis spectrometer, as in our previous work [6].

Several measures were undertaken to lower the limit of detection (LOD) for Cr(VI) in the ISO 17075‐1 method. UV–Vis spectra were collected rather than a single wavelength, and the 400–700 nm range was scanned to verify the peak (with a maximum at 540 nm) related to Cr(VI) and avoid possible interferences. The extra dilution of the samples described in the ISO17075‐1 was not performed to additionally lower the LOD. Reverse PhaseC18 Solid Phase Extraction (SPE) (Hypersep, Thermo Fisher) was employed to remove possible interfering colourants from the extract solution before the analysis. The calibration curve was a seven‐point (0, 20, 60, 125, 250, 500 and 1000 μg/L) linear (R 2 = 0.999) curve. The LOD for Cr(VI) was estimated at 0.3 mg/kg dry leather. ISO 17072‐1 was used to extract sweat‐soluble Co from all leather samples [13, 14]. The extraction was performed in artificial acid perspiration (0.5 g/L of L‐histidine monohydrochloride monohydrate, 5 g/L of sodium chloride, 2.2 g/L of sodium dihydrogen phosphate dihydrate) at pH 5.5 (adjusted by 0.1 M NaOH) at 37°C for 4 h. The Co was measured by inductively coupled plasma mass spectrometry (ICPMS), using a Thermo Scientific iCAP Q. R 2 of the calibration curve was 0.999. The LOD for extractable Co determined by ICPMS was 0.1 mg/kg dry leather.

Both ISO methods apply standardised extraction conditions with defined ratios between the sample mass and the extraction solution volume (both standards: 2 g leather sample per 100 mL of extraction solution). The final mg per kg of dry leather unit is calculated by multiplying the determined concentration in solution (μg/L) by any dilution factor, subtracting a blank value (solution without any leather item, treated and analysed in parallel), multiplying it by the exposure volume (in L) and finally dividing it by the dry weight of the leather sample. The weight of all individual leather samples was measured before the extraction methods using an analytical balance with 0.1 mg readability. Average and standard deviations refer to independent triplicate samples, and blank samples (no leather) were subtracted, if detectable, in all cases.

2.3. XRF‐Screening

A handheld X ray fluorescence (XRF) device (X MET8000, Uedem, Germany) was used to screen the leather surfaces for Cr and Co [15]. For each measurement, the instrument reported elemental content as weight percent (wt%) together with the statistical error estimated by the device from the single measurement. Measurements were performed using the manufacturer recommended alloy analytical mode for leather. The factory settings were applied with an energy source of 40 kV, an analytical depth of 100 μm and a measurement time of 8 s per measurement. The manufacturer did not provide a LOD for Co or Cr in leather for this configuration.

2.4. Statistical Analysis and Considerations

All statistical analyses were performed in R 4.5.0 (2025‐04‐11; R Foundation for Statistical Computing, Vienna, Austria). Data management and statistical analyses were conducted using the packages janitor, dplyr, gtsummary and rstatix, in addition to base statistical functions. Comparisons of concentrations were restricted to measurements above the limit of detection (LOD), and statistical analyses were primarily descriptive given the exploratory nature and sample size of the study.

3. Results

A total of 34 used leather items were analysed (Table 1). The sample comprised watch straps (n = 2), wallets (n = 7), belts (n = 16) and shoes (n = 9). Fifteen items (44.12%) were classified as lightly used or lightly worn, and 19 as heavily worn or heavily used. The most frequent colours were black (n = 15), dark brown (n = 8) and light brown (n = 7). The remaining items were brown (n = 2), blue (n = 1) and dark purple (n = 1).

TABLE 1.

Characteristics and chromium(VI) and extractable cobalt content of used leather items.

ID Product Condition Colour Cr (VI) (mg/kg) (±SD) a Co (mg/kg) (±SD) b XRF Cr (wt%) (±SD) XRF Co (wt%) (±SD)
1 Watch Lightly used Black < LOD < LOD 67.93 (1.40) 0.0
2 Watch Lightly used Black 2.37 (0.02) < LOD 61.33 (0.00) 0.0
3 Wallet Lightly used Blue 2.44 (0.01) 0.56 (0.01) 42.46 (9.81) 9.30 (4.13)
4 Wallet Heavily worn Black 1.95 (0.06) < LOD 60.47 (0.35) 0.0
5 Wallet Heavily worn Dark brown < LOD < LOD 36.78 (1.00) 0.0
6 Wallet Heavily worn Light brown < LOD < LOD 20.22 (7.38) 0.0
7 Wallet Heavily worn Light brown < LOD < LOD 47.52 (3.00) 0.0
8 Wallet Lightly used Dark purple < LOD < LOD 48.70 (2.60) 0.0
9 Wallet Heavily worn Dark brown < LOD < LOD 52.70 (3.88) 0.0
10 Belt Lightly worn Dark brown < LOD 0.34 (0.01) 0.00 (0.00) 0.0
11 Belt Lightly worn Black 1.01 (0.28) 0.48 (0.02) 1.32 (0.00) 0.0
12 Belt Heavily worn Light brown < LOD < LOD 0.00 (0.00) 0.0
13 Belt Lightly worn Dark brown < LOD < LOD 31.77 (0.00) 0.0
14 Belt Heavily worn Dark brown < LOD 1.44 (0.05) 3.66 (23.94) 0.0
15 Belt Lightly worn Dark brown < LOD < LOD 0.00 (17.84) 0.0
16 Belt Lightly worn Black < LOD < LOD 37.84 (0.00) 0.0
17 Belt Heavily worn Light brown < LOD 0.85 (0.05) 37.70 (0.00) 1.63 (0.0)
18 Belt Lightly worn Dark brown < LOD < LOD 45.22 (21.95) 0.0
19 Belt Heavily worn Light brown 0.52 (0.01) < LOD 30.88 (14.56) 0.0
20 Belt Heavily worn Light brown < LOD < LOD 0.00 (0.00) 0.0
21 Belt Heavily worn Dark brown < LOD < LOD 0.00 (25.88) 0.0
22 Belt Heavily worn Black < LOD < LOD 0.00 (0.00) 0.0
23 Belt Heavily worn Black < LOD < LOD 56.28 (2.06) 0.0
24 Belt Heavily worn Black < LOD < LOD 68.54 (32.31) 0.0
25 Belt Heavily worn Black < LOD < LOD 0.00 (0.00) 0.0
26 Shoe Heavily worn Light brown 0.85 (0.01) 0.33 (0.02) 72.49 (0.00) 0.0
27 Shoe Lightly used Brown 4.16 (0.05) 0.42 (0.07) 64.22 (5.41) 0.0
28 Shoe Lightly used Black 0.86 (0.01) < LOD 41.74 (19.27) 0.0
29 Shoe Heavily used Black 3.10 (0.03) < LOD 58.16 (6.05) 0.0
30 Shoe Lightly used Black < LOD < LOD 64.80 (5.25) 0.0
31 Shoe Lightly used Black 0.54 (0.02) < LOD 80.12 (0.00) 0.0
32 Shoe Heavily used Black 1.94 (0.01) < LOD 40.70 (19.71) 0.0
33 Shoe Heavily used Brown < LOD < LOD 8.62 (0.00) 0.0
34 Shoe Lightly used Black 1.51 (0.01) < LOD 53.40 (0.00) 0.0

Abbreviations: LOD, limit of detection; SD, standard deviation; wt%, weight percentage; XRF, X‐ray fluorescence.

a

Cr(VI) using ISO 17075‐1, with pre‐conditioning according to ISO 10195 (relative humidity < 35%), LOD 0.3 mg/kg.

b

Co analysis using ISO 17072‐1 (pH 5.5 at 37°C for 4 h), LOD 0.10 mg/kg.

3.1. ISO Standards

Cr(VI) was detected in 12/34 (35.3%) items, with a mean concentration of 1.77 mg/kg (median 1.73 mg/kg; interquartile range [IQR] 0.86–2.39; range: 0.52–4.16).

Two items exceeded 3 mg/kg, both shoes (ID 27: 4.16 mg/kg; ID 29: 3.10 mg/kg). Eight items exceeded 1 mg/kg (IDs 2, 3, 4, 11, 27, 29, 32, 34). Cr(VI) was most frequently detected in shoes (7/9), compared with watches (1/2), wallets (2/7) and belts (2/16). Among Cr(VI)‐positive items, mean concentrations were 2.37 mg/kg in watches, 2.20 mg/kg in wallets, 0.77 mg/kg in belts and 1.85 mg/kg in shoes.

Cr(VI) detection did not differ by wear category (7/15 lightly used/worn vs. 5/19 heavily worn/used; Fisher's exact test, p = 0.29). Among Cr(VI)‐positive items, concentrations were similar between wear categories (mean 1.84 vs. 1.67 mg/kg; Mann–Whitney U, p = 0.76).

Co was detected in 7/34 (20.6%) items, with a mean concentration of 0.63 mg/kg (median 0.48 mg/kg; interquartile range [IQR] 0.38–0.71; range: 0.33–1.44). Co was detected in 4/16 belts, 2/9 shoes and 1/7 wallets, and in none of the watch straps. Among Co‐positive items, mean concentrations were 0.78 mg/kg in belts and 0.38 mg/kg in shoes. The highest Co concentration was found in a belt (ID 14: 1.44 mg/kg). Co was detected in 4/15 lightly used or worn items and 3/19 heavily worn or used items, with mean concentrations of 0.87 mg/kg vs. 0.45 mg/kg, respectively.

3.2. XRF‐Screening

XRF screening detected Cr in 27/34 (79.4%) items, with a mean of 45.8 wt% (range: 1.3–80.1). Co was detected by XRF in 2/34 (5.9%) items (range: 1.6–9.3 wt%).

4. Discussion

This study shows that used leather items remain a relevant source of exposure to Cr and, in a subset, Co. Cr(VI) was detectable in 12 of 34 items, and two shoes exceeded the current EU limit of 3 mg/kg, with the highest concentration measured at 4.16 mg/kg (ID 27). Co was measurable in 7 of 34 items, with the highest concentration in a belt (ID 14, 1.44 mg/kg). Overall, shoes accounted for most of the higher Cr(VI) concentrations (mean 1.85 mg/kg), consistent with footwear being an important exposure source in clinical settings [8]. Cr and Co did not systematically co‐occur in the same products, and XRF detection of either metal did not predict chemically measurable release.

An important aspect of used leather is that its production date is typically unknown, and items may predate regulatory changes. Since May 2015, leather items intended to come into direct contact with the skin must not be marketed if the content of Cr(VI) is ≥ 3 mg/kg. However, this restriction does not apply to secondhand items. Regulatory efforts and market surveillance primarily target newly marketed products, leaving used leather items as a regulatory blind spot [16]. The longevity of leather creates a ‘legacy effect’ in the circular economy, as durable items produced before the 2015 restriction remain in circulation. As a result, legislative achievements in manufacturing may take decades to ensure safety across the secondhand market. This situation creates an exposure scenario in which consumers may encounter leather items that fall outside the current market controls.

In contrast, new Danish leather items generally comply with Cr(VI) limits. A 2024 Danish market survey of 87 new leather samples found Cr in 83.9% (average 41 mg/kg) and Cr(VI) in 7 out of 20 tested samples (average 1.4 mg/kg), with only one product exceeding the 3 mg/kg regulatory limit [6]. However, a 2021 questionnaire study involving 172 adult Danish dermatitis patients with Cr allergy found no immediate improvement in disease severity or self‐reported leather exposure 5 years after the regulation's adoption, suggesting that the regulation may not adequately protect already sensitised individuals [17]. This aligns with earlier findings that 66% of Cr‐allergic patients reported dermatitis caused by leather exposure, experiencing significantly lower quality of life and higher prevalence of dermatitis [18].

Outside the EU, a 2025 study analysing 105 leather samples from China found that 82% exceeded the EU regulatory limit of 3 mg Cr(VI)/kg, with total Cr ranging from 32 to 45 800 mg/kg and Cr(VI) from 0.5 to 64.3 mg/kg. This study also highlighted that brighter coloured leather products had greater bioaccessible Cr and total Cr(VI) contents, posing potential non‐carcinogenic and carcinogenic risks through long‐term dermal exposure [19].

Another reason for used leather items being a relevant Cr exposure may be the biologically plausible differences between new and used leather. Experimental work has shown that Cr(III) release tends to decrease with use, whereas Cr(VI) release may increase or remain unchanged over time [9]. This may relate to depletion of protective constituents in leather, such as antioxidants and other additives, through repeated exposure to sweat, water, friction and ageing, which can facilitate oxidation processes relevant for Cr(VI) formation and release [9, 20]. In addition, humidity conditions prior to testing and during real‐life use can influence Cr(VI) detectability, and dry indoor conditions are considered relevant for consumers [9, 21]. Notably, visual inspection proved insufficient for risk assessment in our sample. We found no clear correlation between the visible degree of wear and Cr(VI) levels (mean 1.84 mg/kg in lightly used vs. 1.67 mg/kg in heavily worn), suggesting that consumers cannot assess safety based on the physical condition of the leather.

Co deserves specific attention. Danish and other data suggest that Co can be present in leather, potentially linked to dyes and finishing chemistry, including pre‐metallised dyes where Cr or Co may be used [7, 22]. Although evidence of Co in leather products is growing, there is currently no EU legislation that establishes a limit value for Co in leather, which contrasts the regulated status of Cr(VI). This regulatory gap is relevant because leather exposure has been linked to Co related dermatitis in observational data, and leather is repeatedly highlighted as a plausible exposure source [6, 22, 23]. Our data highlight a limitation in using handheld XRF for allergen screening. The item with the highest Co release (ID 14) showed no detectable Co during XRF screening. This implies that XRF may lack the sensitivity to detect low‐level trace metals that are nonetheless capable of significant chemical release in artificial sweat.

The findings of this study are highly relevant considering the changing consumer behaviour, where secondhand clothing and accessories have become more popular among younger consumers as part of sustainability‐oriented choices. If secondhand markets increase the circulation of older leather items, Cr(VI) exposure could remain a driver of allergic contact dermatitis, even after the 2015 restriction [24]. Continued surveillance of consumer exposure, therefore, remains warranted.

Although the 2015 EU restriction specifically targeted Cr(VI), leather remains a relevant exposure source, particularly through secondhand items and ageing related changes in Cr release. In addition, leather may contain other sensitising metals such as Co, highlighting the need for continued surveillance of contact allergy to both Co and Cr. 4.1 Strengths and limitations.

Strengths of the study include: Used leather items were sampled from shops across Greater Copenhagen, representing a range of price levels. This diversity strengthens the assessment of the presence and concentration of Cr and Co in leather items available to Danish consumers. Metal content and release were measured using current ISO‐standardised methods, enhancing the reliability and relevance of the results for comparison with other studies and regulatory benchmarks.

Limitations include: The sample was based on convenience; information about production dates, tanning processes and usage history was not available. It would have been interesting to compare Cr(VI) and Co in used leather items produced before and after the 2015 EU‐regulation. Subgroup comparisons by product type, colour and wear condition were constrained by the small sample size.

4.1. Conclusion

Used leather items in Denmark contain measurable levels of Cr(VI) and Co. Cr(VI) was detected in 12/34 (35.28%) items. The EU limit of 3 mg/kg was exceeded in 2/34 (5.88%) items, both shoes, with a maximum of 4.16 mg/kg. Co was detected in 7/34 (20.6%) items, with a maximum of 1.44 mg/kg. These findings extend evidence from new leather products to the secondhand market. Secondhand purchases may increase exposure to items with potentially hidden concentrations of regulated metals, and reuse should be considered in future exposure assessments and regulatory discussions.

Author Contributions

Mikkel Bak Jensen: conceptualization, funding acquisition, writing – original draft, writing – review and editing, formal analysis, data curation, project administration, resources. Christoffer Kursawe Larsen: writing – original draft, investigation, resources, funding acquisition. Lichen Bruce Guan: methodology, writing – original draft, formal analysis, validation. Jonas F. Hedberg: formal analysis, validation, data curation, supervision, methodology, software. Yolanda S. Hedberg: formal analysis, methodology, validation, data curation, project administration, writing – review and editing, writing – original draft, investigation, supervision, software. Claus Zachariae: supervision, conceptualization, writing – review and editing, software. Jeanne Duus Johansen: supervision, project administration, writing – review and editing, conceptualization, funding acquisition.

Funding

This study has received funding from Aage Bang's Foundation and Canada Research Chairs Program (CRC‐2019‐00425, CRC‐2024‐00200).

Ethics Statement

The authors have nothing to report.

Conflicts of Interest

The authors declare no conflicts of interest.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

  • 1. Thyssen J. P., Strandesen M., Poulsen P. B., Menné T., and Johansen J. D., “Chromium in Leather Footwear‐Risk Assessment of Chromium Allergy and Dermatitis,” Contact Dermatitis 66, no. 5 (2012): 279–285, 10.1111/j.1600-0536.2011.02053.x. [DOI] [PubMed] [Google Scholar]
  • 2. Thyssen J. P., Jensen P., Carlsen B. C., Engkilde K., Menné T., and Johansen J. D., “The Prevalence of Chromium Allergy in Denmark Is Currently Increasing as a Result of Leather Exposure,” British Journal of Dermatology 161, no. 6 (2009): 1288–1293, 10.1111/j.1365-2133.2009.09405.x. [DOI] [PubMed] [Google Scholar]
  • 3. Hansen M. B., Menné T., and Johansen J. D., “Cr(III) Reactivity and Foot Dermatitis in Cr(VI) Positive Patients,” Contact Dermatitis 54, no. 3 (2006): 140–144, 10.1111/j.0105-1873.2006.00802.x. [DOI] [PubMed] [Google Scholar]
  • 4. Hansen M. B., Johansen J. D., and Menné T., “Chromium Allergy: Significance of Both Cr(III) and Cr(VI),” Contact Dermatitis 49, no. 4 (2003): 206–212, 10.1111/j.0105-1873.2003.0230.x. [DOI] [PubMed] [Google Scholar]
  • 5. Unknown , Opinion of the Committee for Risk Assessment and Opinion of the Committee for Socio‐Economic Analysis on an Annex XV Dossier Proposing Restrictions of the Manufacture, Placing on the Market or Use of a Substance Within the EU (European Chemicals Agency (ECHA), 2020), https://echa.europa.eu/de/registry‐of‐restriction‐intentions/‐/dislist/details/0b0236e182446136. [Google Scholar]
  • 6. Jensen M. B., Alinaghi F., Chen I., et al., “Chromium and Cobalt in Leather: A Danish Market Survey,” Contact Dermatitis 91, no. 5 (2024): 398–403, 10.1111/cod.14643. [DOI] [PubMed] [Google Scholar]
  • 7. Thyssen J. P., Johansen J. D., Jellesen M. S., et al., “Consumer Leather Exposure: An Unrecognized Cause of Cobalt Sensitization,” Contact Dermatitis 69, no. 5 (2013): 276–279, 10.1111/cod.12101. [DOI] [PubMed] [Google Scholar]
  • 8. Kursawe Larsen C., Jensen M. B., Isufi D., Zachariae C., Johansen J. D., and Schwensen J. F. B., “Trends in Contact Allergy to Chromium Following the 2015 European Union Leather Regulation,” Contact Dermatitis 94, no. 1 (2026): 67–72, 10.1111/cod.70045. [DOI] [PubMed] [Google Scholar]
  • 9. Hedberg Y. S. and Lidén C., “Chromium(III) and Chromium(VI) Release From Leather During 8 Months of Simulated Use,” Contact Dermatitis 75, no. 2 (2016): 82–88, 10.1111/cod.12581. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10. Mathiason F., Lidén C., and Hedberg Y. S., “Chromium Released From Leather—II: The Importance of Environmental Parameters,” Contact Dermatitis 72, no. 5 (2015): 275–285, 10.1111/cod.12334. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11. European Committee for Standardization , ISO 10195:2018 | IULTCS/IUC 41—Leather—Chemical Determination of Chromium(VI) Content in Leather Thermal Pre‐Ageing of Leather and Determination of Hexavalent Chromium (European Committee for Standardization; ), (2018), https://www.iso.org/standard/73378.html. [Google Scholar]
  • 12. European Committee For Standardization , Leather—Chemical Determination of Chromium(VI) Content in Leather—Part 1: Colorimetric Method (ISO 17075‐1:2017) (European Committee for Standardization; ), (2017), https://www.sis.se/en/produkter/textile‐and‐leather‐technology/leather‐technology/leather‐and‐furs/sseniso1707512017/. [Google Scholar]
  • 13. European Committee for Standardization , ISO 17072‐1:2019(en) Leather—Chemical Determination of Metal Content—Part 1: Extractable Metals (European Committee for Standardization; ), (2019), https://www.iso.org/standard/73706.html. [Google Scholar]
  • 14. European Committee For Standardization , Leather—Chemical Determination of Metal Content—Part 2: Total Metal Content (ISO 17072‐2:2019) (European Committee for Standardization; ), (2019), https://www.sis.se/en/produkter/textile‐and‐leather‐technology/leather‐technology/leather‐and‐furs/ss‐en‐iso‐17072‐22019/. [Google Scholar]
  • 15. Artounian K. and Hamann D., “Handheld X‐Ray Fluorescence Spectroscopy Evaluation of Leather Chromium and Cobalt,” Occupational Medicine 71, no. 6–7 (2021): 298–300, 10.1093/occmed/kqab122. [DOI] [PubMed] [Google Scholar]
  • 16. Thyssen J. P., Menné T., and Johansen J. D., “Hexavalent Chromium in Leather is Now Regulated in European Union Member States to Limit Chromium Allergy and Dermatitis,” Contact Dermatitis 70, no. 1 (2014): 1–2, 10.1111/cod.12182. [DOI] [PubMed] [Google Scholar]
  • 17. Alinaghi F., Thyssen J. P., Zachariae C., and Johansen J. D., “No Immediate Effect of Regulatory Reduction of Chromium in Leather Among Adult Patients With Chromium Allergy,” Contact Dermatitis 85, no. 5 (2021): 514–522, 10.1111/cod.13925. [DOI] [PubMed] [Google Scholar]
  • 18. Bregnbak D., Thyssen J. P., Zachariae C., and Johansen J. D., “Characteristics of Chromium‐Allergic Dermatitis Patients Prior to Regulatory Intervention for Chromium in Leather: A Questionnaire Study,” Contact Dermatitis 71, no. 6 (2014): 338–347, 10.1111/cod.12291. [DOI] [PubMed] [Google Scholar]
  • 19. Liu C., Liu C., Juhasz A. L., Dong W. J., and Ma L. Q., “Human Health Risks of Chromium in Bright‐Colored Leather Products: Speciation‐Based Insights into Dermal Permeation,” Environment International 200 (2025): 109538, 10.1016/j.envint.2025.109538. [DOI] [PubMed] [Google Scholar]
  • 20. Wright A., Laundry‐Mottiar L., and Hedberg Y. S., “The Ability of Sweat and Buffer Solutions to Reduce Hexavalent Chromium of Relevance for Leather Extraction,” Regulatory Toxicology and Pharmacology 133 (2022): 133, 10.1016/j.yrtph.2022.105222. [DOI] [PubMed] [Google Scholar]
  • 21. Graf D., “Formation of CR(VI) Traces in Chrome‐Tanned Leather: Causes, Prevention & Latest Findings,” Journal of the American Leather Chemists Association 96, no. 5 (2001): 169–179. [Google Scholar]
  • 22. Hamann D., Hamann C. R., Kishi P., Menné T., Johansen J. D., and Thyssen J. P., “Leather Contains Cobalt and Poses a Risk of Allergic Contact Dermatitis: Cobalt Indicator Solution and X‐Ray Florescence Spectrometry as Screening Tests,” Dermatitis 27, no. 4 (2016): 202–207, 10.1097/DER.0000000000000200. [DOI] [PubMed] [Google Scholar]
  • 23. Bregnbak D., Thyssen J. P., Zachariae C., Menné T., and Johansen J. D., “Association Between Cobalt Allergy and Dermatitis Caused by Leather Articles—A Questionnaire Study,” Contact Dermatitis 72, no. 2 (2015): 106–114, 10.1111/cod.12319. [DOI] [PubMed] [Google Scholar]
  • 24. Fischer L. A., Voelund A., Andersen K. E., Menné T., and Johansen J. D., “The Dose–Response Relationship Between the Patch Test and ROAT and the Potential Use for Regulatory Purposes,” Contact Dermatitis 61, no. 4 (2009): 201–208, 10.1111/j.1600-0536.2009.01607.x. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.


Articles from Contact Dermatitis are provided here courtesy of Wiley

RESOURCES