Skip to main content
Annals of Pediatric Cardiology logoLink to Annals of Pediatric Cardiology
. 2026 Jul 31;19(4):443–445. doi: 10.4103/apc.apc_310_25

Middle aortic syndrome in a young child: A case successfully managed by a hybrid technique

Ayad Anass 1,✉, Sghir Salah 1, Sellouti Mohamed 1, Abilkassem Rachid 1
PMCID: PMC13475839  PMID: 42603039

Abstract

Middle aortic syndrome is a rare cause of renovascular hypertension in infants. We report a 21-month-old boy weighing 11 kg who presented with severe systemic hypertension (205/117 mmHg) and left ventricular (LV) dysfunction due to diffuse hypoplasia of the thoracoabdominal aorta. Echocardiography and computed tomography angiography showed two coarctation segments involving the superior mesenteric and renal arteries without inflammatory signs. After medical stabilization, acute pulmonary edema and cardiogenic shock developed. A hybrid transabdominal approach with sequential covered-stent implantation achieved favorable recovery, with normalization of blood pressure and improvement in LV function.

Keywords: Hybrid procedure, hypertension, infant, middle aortic syndrome, stent graft

INTRODUCTION

Middle aortic syndrome (MAS) is an uncommon cause of renovascular hypertension resulting from segmental or diffuse narrowing of the distal thoracic or abdominal aorta, accounting for only 0.5%–2% of all aortic coarctations.[1] It may be congenital, due to abnormal fusion of embryonic dorsal aortae, or acquired, secondary to inflammatory arteriopathies such as Takayasu disease.[1] Clinical manifestations depend on the severity and location of the obstruction and often include severe hypertension, heart failure, or claudication.[2] Early recognition and individualized management are crucial to prevent irreversible cardiovascular or renal damage.[3]

CASE REPORT

A 21-month-old male child, born at term with normal development, was referred for evaluation of a cardiac murmur and severe hypertension. On admission, he was alert and in good general condition. Blood pressure was markedly elevated at 205/117 mmHg in the right arm and 211/121 mmHg in the left, while lower limb pulses were weak and nonpalpable. Cardiac auscultation revealed a Grade 3/6 systolic murmur; no hepatomegaly or dysmorphic features were noted.

Electrocardiography showed left ventricular (LV) hypertrophy. Echocardiography revealed severe concentric LV hypertrophy, Grade III mitral regurgitation, diastolic dysfunction (E/E′ =22.4), and reduced shortening fraction (18%).[4] The aortic arch measured 14.3 mm, but the descending aorta could not be visualized, with no diastolic flow in the abdominal aorta. Doppler study identified a continuous high-velocity systolic-diastolic flow (Vmax = 2.3 m/s) at the subcostal level.[4]

Computed tomography (CT) angiography demonstrated a long, severe hypoplasia of the thoracoabdominal aorta measuring only 2 mm in diameter over a 5 cm segment, involving the superior mesenteric and renal arteries, without signs of arteritis [Figure 1].[5] Workup for Takayasu disease, Kawasaki disease, or connective tissue disorder was negative.

Figure 1.

Figure 1

Computed tomography angiography images demonstrate two areas of coarctation of the thoracoabdominal aorta: one located at the level of the left subclavian artery, and the other involving the distal thoracic aorta extending to the celiac trunk. There is also hypoplasia of the sub-isthmic aorta, measuring 8 mm in mean diameter

Initial management with beta-blockers achieved partial blood pressure control, but a few weeks later, the patient experienced cardiogenic shock with acute pulmonary edema and severe LV failure. Mechanical ventilation and inotropic support (dobutamine 20 µg/kg/min) were initiated. Given the life-threatening hemodynamic status and extensive aortic narrowing, a hybrid endovascular–surgical approach was selected.[6]

A small midline laparotomy of approximately 3–4 cm was performed to expose the abdominal aorta. A purse-string suture was placed just above the aortic bifurcation, allowing introduction of a 0.035-inch hydrophilic guidewire (Terumo) and a diagnostic catheter up to the ascending aorta. Contrast injection was used to delineate the stenotic segment and identify the superior mesenteric and renal arteries. Because of the marked narrowing, sequential dotterization and predilatation with 4-mm and 6-mm Mustang balloons (Boston Scientific) were necessary to permit advancement of a 12-French Check-Flo sheath (Cook Medical). During sheath progression, an aortic dissection was noted within the diseased segment. A 3.9-cm covered CP stent (Numed), mounted on a 12-mm balloon-in-balloon system, was deployed across the lower portion of the coarctation. A second 3.9-cm bare CP stent was then implanted in the upper segment, overlapping the initial stent by approximately 50%. Final angiography demonstrated resolution of the coarctation, absence of dissection, and preserved flow within the superior mesenteric and renal arteries [Figures 2 and 3].

Figure 2.

Figure 2

Intraoperative angiography images obtained before and after placement of the two endovascular stent grafts, showing resolution of the dissection image and preserved patency of the superior mesenteric artery

Figure 3.

Figure 3

Computed tomography angiography illustrates the full length of the thoracoabdominal aortic narrowing and the marked collateral circulation that has developed. The celiac artery is opacified only through retrograde flow

Given the potential risk of aortic narrowing at the puncture site, the abdominal aorta was repaired with an end-to-end suture. At the end of the intervention, femoral pulses were satisfactory, and no significant pressure gradient was detected between upper and lower extremities. The patient was returned to the intensive care unit for management of left-sided heart failure and hypertension. He was discharged 1.5 months later, and follow-up echocardiography confirmed good LV systolic function. Follow-up imaging confirmed stent patency without restenosis.[7]

DISCUSSION

MAS is an uncommon but significant cause of secondary hypertension in children.[1,3] The condition may be congenital or acquired, but in infants, congenital origin is more likely when inflammatory markers are negative and supra-aortic branches are spared.[3,4] The pathophysiology of hypertension involves both mechanical obstruction and renovascular activation of the renin–angiotensin system.[3]

Imaging – using echocardiography, CT angiography, or MR angiography – is essential for diagnosis and preoperative planning.[5] It defines the extent of stenosis, collateral circulation, and visceral artery involvement.[5] In this case, diffuse thoracoabdominal narrowing with visceral vessel involvement made standard surgical repair high risk.[6]

Traditional management options include aortoplasty with patch augmentation for short lesions or aorto-aortic bypass for long-segment narrowing.[8] However, in infants, small vessel size and growth potential make prosthetic reconstruction technically difficult.[8] Endovascular angioplasty alone has limited long-term success due to restenosis and vessel recoil.[9] Hybrid approaches, combining limited surgical exposure with endovascular stent placement, offer a less invasive and effective alternative, particularly in critically ill or small patients.[2,6,8]

Recent reports highlight successful hybrid management in pediatric MAS with improved short-term outcomes and acceptable mid-term patency, though reinterventions may be needed with growth.[2,8,10] Careful follow-up is essential to monitor blood pressure control, stent integrity, and somatic growth.[7,9] In our patient, the hybrid procedure achieved immediate hemodynamic stabilization and significant recovery of ventricular function, avoiding the need for complex bypass grafting.[6]

CONCLUSION

MAS in infancy is a rare but severe cause of renovascular hypertension and heart failure.[1] Diagnosis relies on detailed multimodal imaging.[5] Hybrid repair combining open and endovascular techniques can be life-saving when conventional surgery is not feasible.[2,6,8] Early multidisciplinary management and long-term follow-up are crucial for optimal outcomes.[7,9]

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understands that name and initials will not be published, and due efforts will be made to conceal identity, but anonymity cannot be guaranteed.

Conflicts of interest

There are no conflicts of interest.

Funding Statement

Nil.

REFERENCES

  • 1.Delis KT, Gloviczki P. Middle aortic syndrome: From presentation to contemporary open surgical and endovascular treatment. Perspect Vasc Surg Endovasc Ther. 2005;17:187–203. doi: 10.1177/153100350501700302. [DOI] [PubMed] [Google Scholar]
  • 2.Tummolo A, Marks SD, Stadermann M, Roebuck DJ, McLaren CA, Hamilton G, et al. Mid-aortic syndrome: long-term out come of 36 children. Pediatr Nephrol. 2009;24:2225–32. doi: 10.1007/s00467-009-1242-6. [DOI] [PubMed] [Google Scholar]
  • 3.Lin YJ, Hwang B, Lee PC, Yang LY, Meng CC. Mid-aortic syndrome: a case report and review of the literature. Int J Cardiol. 2008;123:348–52. doi: 10.1016/j.ijcard.2006.11.167. [DOI] [PubMed] [Google Scholar]
  • 4.Connolly JE, Wilson SE, Lawrence PL, Fujitani RM. Middle aortic syn drome: Distal thoracic and abdominal coarctation, a disorder with mul tiple etiologies. J Am Coll Surg. 2002;194:774–81. doi: 10.1016/s1072-7515(02)01144-4. [DOI] [PubMed] [Google Scholar]
  • 5.Ayik F, Engin C, Ertugay S, Atay Y. Surgical repair of middle aortic syn drome in a three-year-old patient. J Card Surg. 2011;26:659–62. doi: 10.1111/j.1540-8191.2011.01322.x. [DOI] [PubMed] [Google Scholar]
  • 6.Barral X, de Latour B, Vola M, Lavocat MP, Fichtner C, Favre JP. Surgery of the abdominal aorta and its branches in children: late follow-up. J Vasc Surg. 2006;43:1138–44. doi: 10.1016/j.jvs.2006.01.033. [DOI] [PubMed] [Google Scholar]
  • 7.Porras D, Stein DR, Ferguson MA, Chaudry G, Alomari A, Vakili K, et al. Midaortic syndrome: 30 years of expe rience with medical, endovascular and surgical management. Pediatr Nephrol. 2013;28:2023–33. doi: 10.1007/s00467-013-2514-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Bergamini TM, Bernard JD, Mavroudis C, Backer CL, Muster AJ, Richardson JD. Coarctation of the abdominal aorta. Ann Vasc Surg. 1995;9:352–56. doi: 10.1007/BF02139406. [DOI] [PubMed] [Google Scholar]
  • 9.Coleman DM, Eliason JL, Ohye RG, Stanley JC. Long-segment thoracoabdominal aortic occlusions in childhood. J Vasc Surg. 2012;56:482–5. doi: 10.1016/j.jvs.2012.01.083. [DOI] [PubMed] [Google Scholar]
  • 10.Pilla CB, Fontes VF, Pedra CA. Endovascular stenting for aortic coarctation. Expert Rev Cardiovasc Ther. 2005;3:879–90. doi: 10.1586/14779072.3.5.879. [doi: 10.1586/14779072.3.5.879] [DOI] [PubMed] [Google Scholar]

Articles from Annals of Pediatric Cardiology are provided here courtesy of Wolters Kluwer -- Medknow Publications