The privacy and safety paradox regarding technical compliance and employer enforcement of home office lighting requirements

Roman Sikora 1,#, Ewa Korzeniewska 2,✉,#, Przemysław Markiewicz 1, Adrian Szelągowski 1, Małgorzata Serwach 3
PMCID: PMC13478453  PMID: 42243390

Abstract

The rapid shift to remote work following the COVID-19 pandemic transformed private residential spaces into permanent workplaces, often without professional ergonomic oversight. While occupational lighting is strictly regulated by standards such as EN 12,464–1, these norms are legally unenforceable in private homes due to privacy regulations. This study addresses the "Privacy-Safety Paradox" by conducting a comparative legal analysis of employer responsibilities versus privacy rights in the EU (including France, Germany, Italy, Portugal, and Poland) and the USA. It presents a case series analysis of five distinct home-office scenarios, evaluating illuminance levels (Eavg, Emin) and uniformity (U0) against occupational safety requirements. Results reveal a 100% non-compliance rate, with critical deficiencies identified in makeshift workspaces. The most severe case exhibited an average illuminance of only ~ 188 lx and a minimum of ~ 22 lx, which is drastically below the biologically required thresholds for visual health and circadian regulation. The study identifies a systemic “compliance gap” where legal protections of the home, such as the German Selbstauskunft model or the Italian "right to disconnect", limit the employer’s ability to perform physical audits. To mitigate this risk, the authors propose a simplified self-assessment checklist designed to allow remote workers to identify and correct visual hazards without specialized photometric equipment.

Keywords: Workplace lighting, Home office, Visual ergonomics, Remote work, Illuminance compliance, Occupational health

Subject terms: Engineering, Health occupations, Risk factors

Introduction

The beginning of 2019 became a breakthrough period for the world1. The SARS COV-2 virus pandemic sweeping the globe has changed many aspects of the everyday life of almost every person. To prevent the spread of the virus, some changes were made to stop the pandemic. One of the factors gradually introduced into people’s lives was the transfer of millions of workers to the home space1. Work in home office mode has significantly contributed to improving the global situation in the fight against the pandemic2–7. With the transfer of activities to the home space, employees around the world had to adapt their homes to be able to perform work duties away from their main workplaces. Employers were obliged to provide their employees with appropriate conditions to perform professional activities at home. Unfortunately, under the influence of the new, rapidly developing epidemiological situation, these duties have been abandoned in many cases, leaving people unprepared to work in a home office. In the long term, this contributed to a decrease in the effectiveness of activities performed, as well as the deterioration of the physical and mental health of employees8–15. Moreover16–26, describes the impact of indoor lighting on work efficiency and employee well-being. Ensuring proper lighting conditions also affects the health of workers.

The rapid shift to home-based work has exposed a significant regulatory gap common to many legal systems: the conflict between the employer’s responsibility for occupational safety and the employee’s right to privacy in their domicile. Professional activity in a home environment is not limited to digital tasks but is characterized by high variability, including tight d eadlines, resource scarcity, and the frequent overlap of domestic responsibilities such as childcare or household maintenance. While occupational health and safety (OHS) standards are stringent for traditional offices, their enforcement becomes legally ambiguous when the “office” is a private living room. The legal landscape in the European Union is diverse, yet it shares a common challenge: the "inviolability of the home" often outweighs the employer’s ability to conduct physical audits.

Adequate lighting is a key condition for ensuring effective, comfortable and safe work. Lighting conditions are an extremely important external factor affecting the proper functioning of the body. Good lighting contributes to precision, concentration and ensures human well-being. Taking into account the above-mentioned factors, the appropriate lighting conditions in the space in which people stay should be ensured. Work transferred from offices to residential homes should be performed with adequate lighting, and the time spent on tasks such as working at a computer, reading or watching films should be provided in comfortable conditions. Adequate lighting in rooms should be provided for both children and adults. In the case of children who received distance education during the SARS COV-2 pandemic, their time spent at home increased significantly. Due to many hours spent in living conditions, special attention should be paid to proper lighting27–30. Attention should be paid not only to workplaces in plants, offices or educational institutions, but also to those organized in one’s own home. The prevailing lighting conditions can be checked based on the measurements taken. In the case of the above-mentioned surfaces, the normative requirement is to measure the illumination intensity.

The EN 12,464–1 Light and lighting standard31 defines the areas in which they should be performed and determines the required lighting intensity values. Currently, there are no existing standards and regulations regarding the method of lighting in private residential buildings, clear standards regulating the measurement method, its frequency or guidelines regarding the qualifications of the person responsible for the tests and their interpretations. One way to assess the lighting used may be to compare private apartments to office spaces, the lighting conditions of which are regulated by standards. Based on the above-mentioned guidelines, the opinion issued about lighting conditions is not subjective but only confirmed by regulations and values developed by specialists in the field of lighting technology. An important issue in the design and evaluation of indoor lighting is how to take into account, in the conducted analysis, in addition to artificial light, the daylight32–36.

In32, the authors deal with the effects of daylight on indoor lighting. The purpose of the study described33 is to compare three methods for generating individual lighting characteristics to model user behaviour in a lighting environment. The created concept of “person” is used to represent typical users, highlighting their needs, perspectives and expectations.

In34 authors proved that CCT is one of the most important lighting factors influencing subjective comfort and preferences. Detailed analysis shows that lower CCT values are considered more comfortable and preferred for relaxation, while higher CCT values are considered more comfortable and preferred for work. Authors in34 conducted research related to the impact of lighting conditions on the perceived quality of space, comfort, cooperation, motivation, distraction and fatigue in the school laboratory. The presented results show that, according to most respondents, the room seemed spacious in daylight and at high color temperatures but cramped at low temperatures. A study reported in36 determined the effects of a correlated color temperature of 2700 K versus 6000 K, 500 lx at a desk on users’ performance and physiology during hourly exposure in the morning and afternoon. In their article37, Vasquez’s group presented the results of research conducted on representatives of Brazil, Colombia, Denmark, Italy, Poland and Japan aimed at examining the factors influencing participants’ satisfaction with lighting conditions in the home office, emphasizing user satisfaction with the visual environment. The presented data show differences in satisfaction depending on profession, gender and continent of residence of the participants.

According to the results of a study included38, the use of home as a workplace has become an important feature of labor markets in many Western economies, and this number has increased significantly in recent years, helped by the pandemic. By 2015, about 1 in 6 workers in the European Union worked from home for at least part of their working days. It is important to note that changes in living, working and commuting activities due to working from home have a huge impact on greenhouse gas emissions. Greenhouse gas emissions during a typical day (24 h) when working from home and working in the office were estimated and compared. The results showed in39 that working from home can reduce greenhouse gas emissions by 29.11% (4.06 kg CO2/person/day) compared to performing the same tasks in the office. The aim of the research published in40 was to evaluate the potential impact of circadian lighting design recommendations on energy that are gaining popularity in various typical applications, such as offices and classrooms. Two applications—an open office and a classroom—were simulated, and the output power clearance, spectral characteristics, surface reflectance distribution and desk orientation were examined to scale the potential impact. The article41 reviewed and summarized the effects of the lighting environment on task performance, particularly for audiences in built environments. Existing research has included a variety of performance tests on cognitive and perceptual performance, visual acuity and response, memory, reasoning and work performance. The purpose of the study, the results of which were published in42, was to identify daylighting design strategies that can optimize the visual environment in kindergarten classrooms in the context of Greece’s climate data, as well as to evaluate climate-based daylight modelling indices as an evaluation tool when designing daylighting processes. In addition to analysing lighting performance in the area of the visual task, there is also an assessment of the energy demand. Research results published in43 show that by taking into account emerging changes in hybrid work models and activity-based workspace environments, energy demand in the office building sector can fall below pre-pandemic Covid-19 levels, with significant energy savings of up to 50% less energy compared to the pre-pandemic situation. The choice of the adopted technology used in lighting has a significant impact on the amount of energy consumed as discussed by the authors in43.

In44–53, the authors deal with the problem of adapting lighting conditions to the individual needs of each person, which naturally arise from the different needs of individuals in the population. One important aspect of ensuring good lighting conditions is to reduce glare in the design of lighting systems, which the authors address in54. Lighting conditions should be constantly monitored to respond, if necessary, to changes that occur during the operation of the installation as described in55,56. Even a factor such as the view from a window can affect the well-being of the occupant. This issue is presented in57.

Recent advancements in lighting research emphasize that illuminance levels and correlated color temperature (CCT) are not merely technical parameters but critical factors influencing worker well-being, stress reduction, and cognitive performance. According to recent studies on Human-Centric Lighting (HCL), properly adjusted lighting can significantly reduce stress levels, with CCTs of 4000 K and 6000 K showing particular effectiveness in workplace design58. However, the interaction between illuminance and CCT is complex; while levels exceeding 750 lx may enhance attention and comfort in simulated VDT-based office tasks59, they can also lead to increased tension if not balanced with appropriate spectral characteristics60. Furthermore, the integration of adaptive lighting systems that monitor real-time cognitive workload and emotional states is becoming a key focus in modern office design to optimize the indoor environment for the human circadian system61. In the context of remote work, where professional oversight is absent, these sophisticated HCL strategies are virtually impossible to implement, potentially exacerbating the health risks associated with inadequate home-office lighting.

The paper presents the results of measurements and analysis of lighting parameters for selected working areas. These are areas in residential buildings that, as a result of restrictions related to the Covid-19 pandemic, have become for residents their temporary workplaces. Unlike previous international studies that predominantly focus on subjective worker comfort and perceived satisfaction, this research adopts a unique interdisciplinary approach. It bridges engineering in situ measurements with a comparative legal analysis of the “Privacy-Safety Paradox”, identifying a critical gap in the enforceability of occupational standards within private domestic spheres.

The privacy-safety paradox in remote work regulations

Establishing the legal framework for remote work requires a detailed examination of national labour codes and constitutional provisions. While the general conflict between privacy and safety has been outlined in the introduction, this section analyzes how specific jurisdictions (France, Poland, USA, etc.) translate these abstract rights into concrete employer obligations. The transition from „office-based” to „home-based” work necessitates a redefinition of the “workplace” and a reassessment of the tools available for health and safety monitoring.

The following legal comparison utilizes a functional and normative research method, analyzing the transposition of EU Directives (89/391/EEC and 90/270/EEC) into national legal frameworks and their collision with constitutional privacy protections. Table 1 presents a comparative analysis of this issue across multiple jurisdictions: the European Union (general framework), the United States (liberal approach), and Poland (detailed statutory regulation), illustrating that the lack of effective lighting oversight is a transnational structural problem.

Table 1.

Comparative analysis of employer responsibilities and constitutional privacy rights in remote work.

Jurisdiction Employer responsibility for home office safety Meetings / assessment frequency Right to inspection (Home) The regulatory conflict (Research gap) Privacy protection & inviolability of the home

United States

(OSHA Policy / Directive CPL 02–00-125)62

Limited. OSHA explicitly states it "will not conduct inspections of employees’ home offices" and does not hold employers liable for home office conditions No routine inspections; focused on complaint-driven audits None. The responsibility for the home environment is largely shifted to the employee Lack of regulation leads to voluntary (and often ignored) safety standards US Constitution: Protection against unreasonable searches and seizures
Germany63

High. Protection of personal rights and home inviolability (Art. 13 Grundgesetz)

Arbeitsschutzgesetz (ArbSchG): imposes on the employer the obligation to assess the risk (Gefährdungsbeurteilung) of working in a remote position

Periodic risk assessment (Gefährdungsbeurteilung) Very Limited. Physical inspections are rare; employers often use self-declaration with photos Monitoring systems (e.g., keyloggers) are strictly prohibited. Privacy takes precedence over direct OHS control Basic Law: Fundamental right to the inviolability of the home
France64 High (Art. L1222-9—L1222-11 Labor Code). Requires regular meetings to discuss workload and OHS Annual meetings (min. once a year) to discuss OHS and workload Regulated. Inspection must be transparent and "non-obtrusive"; constant screen monitoring is illegal Employer must ensure safe conditions through dialogue, but physical access remains difficult without consent Civil Code: Right to respect for private life
Portugal65 High (Código do Trabalho, Art. 165–171). Modern remote work law (2021) Initial setup assessment and periodic reviews Conditional. Employer may inspect equipment/OHS with 24-h notice and only in the presence of the worker. The applicable regulations provide for the employee’s right to work remotely One of the few systems with a clear inspection framework, though it still relies on employee cooperation Constitution: Inviolability of home; remote work law must respect private life
Italy66 Contract-based (Lavoro Agile framework) Annual written notice to the worker regarding OHS risks

Pre-defined. Rights must be specified in a mandatory “accordo individuale”

The law introduces privileged groups that are first to be entitled to remote work (e.g. parents of children up to 12 years old or people caring for people with disabilities)

Must respect the "right to disconnect" (diritto alla disconnessione) and privacy outside work hours Constitution: Home is inviolable; legal limits on audits
Belgium67 Code of Well-being at Work (VDU equipment focus) Periodic ergonomic reviews as per CAO 85 Restricted. Practically hard to enforce in private residences Strong emphasis on the right to disconnect creates a barrier to employer monitoring the workplace outside designated hours Constitution: Specific consent required for entry
Netherlands68 Arbeid somstandighedenbesluit (Arbowet). Safe home environment mandated Integrated into company’s OHS and risk management policy Restricted. Compliance is required but enforcement is limited by privacy A system based on trust and the impossibility of control without the employee’s consent means that ensuring an ergonomic workstation remains in the declarative sphere Constitution: General right to privacy and protected home
European Union69–71 High. According to Directives 89/391/EEC & 89/654/EEC, employers must ensure safety in all aspects related to work Implementation varies by national legislation No EU-level Labor Inspectorate. Enforcement is delegated to Member States. However, the ‘right to inspection’ is fundamentally restricted by the EU Charter of Fundamental Rights (Article 7), making national enforcement of OSH standards in private homes legally complex A systemic “enforcement gap” exists because the EU mandates safety standards but simultaneously provides the legal tools (privacy rights) that prevent their verification in remote settings EU Charter of Fundamental Rights:: Respect for private and family life

Poland (Case Study Context)

(Labour Code, Art. 6728 et seq.)72

High. Strict liability for accidents; employer must provide equipment and cover energy costs During initial setup or upon employee’s request Conditional. Inspection allowed only during work hours and strictly with the employee’s direct consent Creates a “liability trap” for employers and a “health trap” for workers who lack ergonomic knowledge Constitution: Right to the inviolability of the home

As shown in Table 1, regardless of the jurisdiction, the physical verification of lighting conditions (illuminance, glare, uniformity) by the employer is either legally restricted or administratively abandoned. Consequently, the burden of ensuring visual comfort falls on the employee, who typically lacks the necessary engineering knowledge and photometric equipment. This regulatory deadlock serves as the rationale for the case study analysis presented in this paper, where Poland is used as a representative example of this global challenge. From the point of view of the employer’s liability, it is worth checking the lighting conditions at the employee’s house.

A fundamental theoretical challenge in remote work regulations is the legal spatial definition of the „workspace” within a private domicile. A distinction must be drawn between „formal telework” in a dedicated, partitioned room and „ad-hoc remote work” performed in communal areas like kitchens or living rooms. In the latter case, the boundary of the employer’s jurisdiction becomes blurred. If the workspace is not physically isolated, any attempt at an ergonomic audit or the installation of professional lighting equipment inherently encroaches upon the private sphere of other household members. This spatial ambiguity creates a „grey zone” where the employer’s duty to provide equipment similar to office standards (as per OHS requirements) becomes practically and legally impossible to execute.

Beyond the employer-employee relationship, another critical stakeholder is the occupational physician. Under EU health surveillance principles, the physician’s role is to assess the compatibility between the worker’s health status and their workstation conditions. However, the „Privacy-Safety Paradox” creates a significant procedural gap for occupational medicine. While the physician must evaluate risks such as digital eye strain (computer vision syndrome) and circadian disruptions caused by poor lighting, they lack the legal authority to conduct home environment audits without explicit invitation. This limits the physician to reactive medicine based on patient self-reporting, rather than preventive oversight based on objective measurements of illuminance and uniformity. Consequently, the occupational physician becomes a silent witness to deteriorating ergonomic standards in home offices, unable to fulfill their preventive mandate due to the inviolability of the employee’s home.

The technical impossibility of conducting a full photometric audit according to EN 13,03273 standards, due to the lack of access to technical datasheets for private luminaires and the inability to perform destructive testing or laboratory characterization of lamps, is not a limitation of the study design, but a primary empirical finding. This represents the “Technical Enforcement Gap” within the Privacy-Safety Paradox. It demonstrates that even if an employer intended to verify compliance, the professional tools used in office lighting design (such as maintenance factors and photometric files) are practically non-transferable to the domestic sphere.

Methodology for measuring illumination intensity on the surface of the visual task area

The study follows an in situ assessment methodology to evaluate the immediate exposure of workers in ‘as-found’ conditions. Consequently, laboratory photometric procedures (as per EN 13,03273) and theoretical maintenance factors were excluded, as the primary objective was to document the real-world compliance gap rather than to model a controlled lighting environment. Furthermore, due to the private nature of the workspaces, detailed technical datasheets for the existing residential luminaires were unavailable, mirroring the real-world lack of employer oversight in home-office ergonomics.

Measurements were intentionally conducted under artificial lighting conditions (at night or with windows shielded) to represent a worst-case scenario. This approach ensures that the workspace meets safety requirements regardless of weather or time of day, providing a stable baseline for legal and ergonomic compliance evaluation. This methodology aligns with the requirement that occupational lighting must provide adequate illuminance even in the absence of natural light.

The home-office spaces analyzed in this study were located in standard residential apartments with a consistent clearance height of 2.6 m. The internal surfaces (walls and ceilings) were finished in light colors (predominantly white or off-white) with typical reflection factors for residential interiors (approx. 0.7–0.8 for ceilings and 0.5–0.6 for walls). The furnishings at each workstation consisted of standard office or domestic desks and chairs, positioned according to the users’ daily work habits.

The research covered the visual task area, which included desktops intended for working at a computer, but also writing and reading activities are performed on them. According to the EN 12,464–131 standard, the illumination intensity in the visual task area should be 500 lx. This value allows for comfortable work that does not cause eye strain. During work with a computer and with CAD or BIM programs, the EN-12464–131 standard recommends that the illumination intensity in the visual task area should be 700 lx. Illuminance measurements were made using the Sonel LXP – 2 Luxmeter. According to the device specifications, luxmeter is a class B (spectral uncertainty f1 is ± 6%, cosine matching error f2 is ± 3%, linearity error f3 is ≤  ± 2%) .

Beyond the device-specific error (± 5% basic error, < 6% spectral matching), the total expanded uncertainty of the in situ measurements was estimated by considering additional factors such as the operator’s positioning. a. While a formal laboratory-grade uncertainty budget is difficult to fully quantify in non-controlled environments, we conservatively estimate the combined uncertainty from 5 to 12%. Crucially, since the recorded illuminance deficits in most cases exceeded 50–80% of the EN 12,464–131 requirements, the conclusions regarding non-compliance remain scientifically robust and statistically significant, as the gap far exceeds any potential measurement error.

Before the measurement process, the tested rooms were dimensioned, taking into account both the working surfaces and the window openings located in the given space. On the basis, an upper projection of the room was prepared, and then the light sources were identified and inspected. The type of lighting luminaire used and its location, as well as the light source used, were identified.

The measurements were made for a measuring grid with a mesh size of 10 cm x 10 cm. Given the multifunctional and often confined nature of home-office spaces, the distinction between the “task area”, “surrounding area” and “background” (per EN 12,464–131) is frequently blurred, a finding that underscores the difficulty of adapting residential rooms to professional office standards. Measurements were taken after the stabilization of the measuring equipment. In rooms equipped with roller blinds, the measurement was performed when they were completely closed to eliminate the influence of external lighting, for example from external lighting. Measurements were made for five workplaces used by students, children and teenagers at school age.

The standard31 introduces average illuminance EAVE and illuminance uniformity D to analyze the obtained results. The average illuminance is calculated from Eq. (1):

graphic file with name d33e659.gif 1

where:

Ei – illuminance at a given measurement point, (lx),

n – number of measurement points.

The illuminance uniformity U0 is calculated from Eq. (2):

graphic file with name d33e683.gif 2

EMIN – minimum illuminance on a surface, (lx),

EAVE – average illuminance on a surface, (lx).

The study focused exclusively on the physical measurement of lighting parameters (illuminance and uniformity) within private residential environments. No human subjects were involved in the measurement process, and no experimental protocols involving humans or human tissue were conducted. Access to the private premises was granted voluntarily by the property owners solely for technical photometric measurements. The study was explained in detail to all owners, and their informed consent was obtained before any procedures were performed. Therefore, the study did not require approval from an ethics committee as it does not constitute human subject research.

Analysis of lighting conditions of workplaces

To provide a comprehensive assessment of domestic work environments, five distinct case studies (designated TA1–TA5) were selected for detailed analysis. These cases were chosen to represent a diverse range of typical home-office scenarios, differing in terms of user demographics (age, visual needs), spatial constraints, and room occupancy. All technical photometric measurements were performed in accordance with relevant institutional guidelines, and explicit informed consent was obtained from all property owners prior to entering the premises. In all analyzed cases, the workstations were located in residential apartments in urban areas. The measurements were performed on a horizontal workplane (the desk surface) defined at a standard height of h = 0.75 m above the floor. Internal walls and ceilings were finished in light colors with standard reflectance. While external obstructions such as neighboring buildings or trees were present in some cases, they did not impact the results as all measurements were conducted under artificial light only. Table 2 summarizes the key characteristics of each analyzed workplace, establishing the context for the photometric measurements presented in subsequent sections.

Table 2.

Characteristics and user profiles of the analyzed home office workplaces (TA1–TA5).

Case ID User profile & primary activity Risk factors & ergonomic constraints Room area (m2) Lighting configuration
TA1

University Student / Remote Worker

(10 h/day usage)

Visual impairment (glasses required); High exposure time 9.90 Desk lamp, wall lamp, and central ceiling chandelier
TA2

High School Students (Siblings)

(Shared space, learning/entertainment)

Left-handedness (one user); Visual defect (contact lenses); Multi-user desk occupancy 7.74 Desk lamp (movable), ceiling downlights, and decorative LED strip
TA3

Early School Age Child

(Education/Writing)

Left-handedness; Developing visual system; Partial lighting failure (50% damage) 6.72 Desk lamp, ceiling downlights (one faulty)
TA4

Student / Designer

(Precision CAD/BIM work)

High visual precision required (> 700 lx recommended); Corrective glasses used 10.75 Desk lamp (low power), central ceiling chandelier
TA5

University Student

(Rented accommodation)

Rented space (limited modification options); Small room geometry causing potential glare 9.62 Free-standing floor lamp, central ceiling chandelier

In the next sections, due to the significant discrepancies in illuminance intensity between the analyzed cases (ranging from extreme underexposure in TA4 to high intensity in TA3), the color scales in the isoline maps presented for each described case, have been normalized to the maximum value recorded in each specific room. This approach was chosen to effectively visualize the internal distribution and uniformity (U0) patterns within each workspace. Absolute lux values are indicated by the specific color bars accompanying each figure, while the gradient illustrates relative intensity distribution.

TA1 workplace

The analyzed workplace is used by a full-time student who combines studies with home office work. The mentioned person used the workplace for up to 10 h a day, most often to perform professional duties, learn via electronic means of communication, and use the computer for entertainment purposes. The user of the examined space wore glasses, was right-handed and had a visual impairment. For this reason, in accordance with the EN-12464–131 standard, the required illuminance should increase up to 750 lx.

The tested workplace was located in one of the rooms in a multi-family building. The apartment was located on the seventh floor of a skyscraper located in Warsaw. The dimensions of the tested room were 3.3 m × 3 m (area 9.9 m2). The location of the building in relation to the cardinal directions is presented in Fig. 1. The windows in the analyzed room face west. The desk area was assumed as the workplace. The desk in the room being examined is located in the corner of the room. It was placed sideways to the window surface. Its dimensions are 1 m × 0.6 m. The light sources in the room were: a desk lamp placed on the right side of the desk, a wall lamp and a chandelier suspended in the central part of the room, as illustrated in Fig. 2.

Fig. 1.

Fig. 1

Location of the building with the cardinal directions where the workplace marked as TA1 is located.

Fig. 2.

Fig. 2

Location of lighting luminaires illuminating the TA1 workplace.

Table 3 lists the parameters of lighting luminaires and light sources used to illuminate the room in which the TA1 workplace is located.

Table 3.

List of parameters of lighting fixtures and light sources used to illuminate the room in which the TA1 workplace is located.

Desk lamp
Location (length and width in the room) 90 cm × 20 cm
The used light source LED: PHILIPS Softone
Power of the light source 16 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Additional features Adjustable lamp arm
Wall lamp
Location (length and width in the room) 270 cm × 10 cm
The used light source Compact fluorescent lamp: PHILIPS GENIE
Power of the light source 8 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Chandelier—3 light sources
Location (length and width in the room) 160 cm × 160 cm
The used light source Source LED Philips
Power of the light source 3 × 9 W = 27 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Luminous flux 3 × 806 lm = 2418 lm
Rated current of a single lamp 85 mA

The average illuminance in the workplace is EAVG = 444 lx. The maximum measured value is EMAX = 836 lx. The lowest value of illumination in the task area was EMIN = 148 lx. The illuminance uniformity is equal to 0.33. The measurement results are summarized in Table 4.

Table 4.

The results of illuminance measurements in the visual task area TA1 in lx.

y (cm) x (cm)
5 15 25 35 45 55 65 75 85
5 148 287 298 362 418 548 653 647 401
15 234 276 385 451 507 627 724 732 501
25 230 287 403 470 515 672 836 819 609
35 218 263 392 403 506 651 770 704 576
45 208 221 337 375 418 517 528 698 432
55 203 284 307 277 342 310 354 317 342

To ensure maximum rigor in the absence of a professional laboratory environment, a measurement grid of 10 × 10 cm was applied. This density significantly exceeds the minimum requirements of EN 12,464–131 for spaces of this scale, providing a high-resolution map of illuminance distribution. The ‘visual task area’ was strictly defined as the 40 × 60 cm zone directly in front of the operator where the primary tasks (reading/writing) occur. By applying this granular approach, we ensured that even the localized peak values were captured, confirming that the failure to meet standards is a systemic issue, not a result of poor sampling.

TA2 workplace

The workplace was located in a room used by two young people of the same age attending secondary school. It was used primarily for learning and entertainment purposes. The average time which was spent at the analyzed computer workstation was approximately 5 h a day. One of the siblings has a vision defect and wore contact lenses to correct the defect. They often used the examined site at the same time. One of them was left-handed (Fig. 3).

Fig. 3.

Fig. 3

Illuminance isolines in the visual task area TA1.

The analyzed workplace was located in a room in an apartment in a multi-family building on the sixth floor. The room had an area of 7.74 m2 with dimensions of 4.3 m × 1.8 m. The windows face southwest. The orientation of the multi-family building in which the room was located concerning the cardinal directions is shown in Fig. 4. The desk in the examined room is used as a two-station desk with dimensions of 1.8 m × 0.6 m. It took up the entire width of the room. There was a desk lamp with a movable arm on the desk surface, illuminating its left side (additional lighting for a left-handed user). There were five LED sources in the form of recessed downlights located in the ceiling made of cardboard and plaster structures. Additional decorative lighting was provided by a 12.2 m long LED strip built into the ceiling recess around the entire perimeter of the room (Fig. 5).

Fig. 4.

Fig. 4

Location of the building in relation to the cardinal directions where the workplace marked as TA2 is located.

Fig. 5.

Fig. 5

Location of lighting fixtures illuminating the TA2 workplace.

Table 5 contains the parameters of lighting luminaires and light sources used to illuminate the room in which the TA2 workplace is located.

Table 5.

List of parameters of lighting fixtures and light sources used to illuminate the room in which the TA2 workplace was located.

Desk lamp
Location (length and width in the room) 90 cm × 20 cm
The used light source LED: OSRAM VALUE CLASSIC
Power of the light source 4.9 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
CCT color temperature (K) 3300
Additional features Adjustable lamp arm
Downlight
Location (length and width in the room)

80 cm × 10 cm; 150 cm × 10 cm;

80 cm × 170 cm; 150 cm × 180 cm

The used light source LED GU10 5 W
Power of the light source 4 × 5 W = 20 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Luminous flux 4 × 650 lm = 2600 lm
CCT color temperature (K) 3000
LED tape
The used light source LED Kanlux LED LEDS -B
Length (m) 12.2
Power of the light source 4.8 W/m ≈ 59 W
Supply voltage 230 V AC / 12 V DC
CCT color temperature (K) 3000

In the case of TA2 workplace, the average illuminance is equal to EAVG = 376 lx. The calculated illuminance uniformity in the visual task area is 0.39 (Fig. 6).

Fig. 6.

Fig. 6

Illuminance isolines in the visual task area TA2.

Analyzig the measurement results the maximum value of illuminance is EMAX = 1070 lx and the lowest value is EMIN = 146 lx. The highest illuminance values were obtained in the task area near the installed desk lamp and one downlight luminaire located above the desk lamp. Installing a downlight with an LED source allowed for increased uniformity of illumination of the task area (Table 6).

Table 6.

Results of illuminance measurements in the visual task area TA2 in lx.

y (cm) x (cm)
5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175
5 188 227 296 309 400 380 393 308 303 301 286 265 245 238 229 256 307 219
15 196 221 354 331 387 488 456 405 396 411 395 344 311 311 296 295 268 235
25 197 224 381 388 446 586 509 451 406 423 407 367 323 324 306 297 265 229
35 204 260 432 428 526 947 635 530 443 435 403 372 334 335 308 281 261 219
45 208 260 439 422 611 981 893 611 467 408 385 364 369 307 285 247 227 176
55 150 233 421 415 650 1070 923 709 513 392 372 414 393 292 271 263 192 146

TA3 workplace

The examined workplace was used by a child of early school age primarily for educational purposes. Writing and reading activities as well as computer operation were performed on it. The young user was left-handed and has no visual impairments. The analyzed workplace was located in a three-room apartment in a multi-family building. The room has a rectangular shape with dimensions of 2.8 m × 2.4 m and the area of 6.72 m2. The windows in the examined room face northwest (Fig. 7). The workplace was a desk placed in the corner of the room, sideways to the window area with dimensions of 1 m × 0.5 m.

Fig. 7.

Fig. 7

Location of the building in relation to the cardinal directions where the workplace marked as TA3 is located.

The tested room was lit in the form of a desk lamp. There was a desk lamp on the surface of a small table and four LED sources in the form of recessed downlights in the suspended ceiling structure made of cardboard and plaster. The office lamp was equipped with a movable arm illuminating the left side of the desk (additional lighting for a left-handed user). At the time the measurements were taken, one of the light sources in the downlight fixtures did not function fully. The damage was estimated at 50%. The dimensions and location of the workplace and light points are shown in Fig. 8.

Fig. 8.

Fig. 8

Location of lighting fixtures illuminating the TA3 workplace.

Table 7 contains the parameters of lighting luminaires and light sources used to illuminate the room in which the TA3 workplace is located (Fig. 9).

Table 7.

List of parameters of lighting fixtures and light sources used to illuminate the room in which the TA3 workplace is located.

Desk lamp
Location (length and width in the room) 270 cm × 40 cm
The used light source LED energy-saving SMD2835
Power of the light source 15 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Downlights luminaires
Location (length and width in the room) 30 cm × 10 cm; 210 cm × 10 cm; 260 cm × 10 cm
Power of the light source LED SMD2835
Supply voltage 3 × 6 W = 18 W
Supply voltage 230–240 V
The frequency of the supply voltage 50–60 Hz
Luminous flux 3 × 600 = 1800 lm
Rated current (A) 0.12

Fig. 9.

Fig. 9

Illuminance isolines in the visual task area TA3.

For the TA3 workplace, the average illuminance is EAVG = 378 lx. Moreover, the maximum value of illuminance is EMAX = 1691 lx and the lowest value is equal to EMIN = 143 lx. Therefore, the illuminance uniformity in the visual task area is 0.30 Table 8.

Table 8.

Results of illuminance measurements in the visual task area TA3 in lx.

y (cm) x (cm)
55 115 225 335 445 555 665 775 885 995
55 154 160 177 188 221 240 301 660 1071 1451
115 153 156 175 187 215 248 346 635 987 1691
225 151 156 170 180 203 245 389 558 846 1081
335 145 152 164 167 189 222 373 461 726 879
445 143 148 151 155 167 181 268 286 282 270

TA4 workplace

The next analyzed case was a workplace used by a mechatronics student who combined studies with remote work. Working as a designer requires many hours spent at a desk, approximately 8–9 h a day. The main factor characterizing the tested position was the location of a laptop with an additional monitor to improve the performed work. In addition, the workplace was used for educational purposes. The user wore glasses adapted for working at a computer and was right-handed.

The workplace was located in a multi-family building on the second floor. The room in which the workplace was located has an area of 10.75 m2 and dimensions of 4.3 m × 2.5 m. The orientation of the building in relation to the cardinal directions is illustrated in Fig. 10. The window openings in the examined room were directed to the east. The desk (workplace) in the analyzed room was located in the corner of the room and had the dimensions 1.2 m × 0.7 m. It was made in the form of a countertop combined with a shelf in the form of a so-called extension. It was placed sideways to the window plane.

Fig. 10.

Fig. 10

Location of the building in relation to the cardinal directions where the workplace marked as TA4 is located.

The lighting in the room was a desk lamp and a chandelier. The parameters of these devices are listed in Table 9 and the location is shown in Fig. 11.

Table 9.

List of parameters of lighting fixtures and light sources used to illuminate the room in which the TA4 workplace is located.

Desk lamp
Location (length and width in the room) 110 cm × 0.2 cm
The used light source LED source
Power of the light source 15 W
Supply voltage 230 – 240 V AC / 5 V DC
The frequency of the supply voltage 50–60 Hz
Luminous flux (lm) 700
Chandelier
Location (length and width in the room) 240 cm × 130 cm
Light source used DLED Lumenix
Power of the light source 3 × 8 W = 24 W
Supply voltage 230 – 240 V
The frequency of the supply voltage 50—60 Hz
Luminous flux (lm) 3 × 2640 lm
Color Temperature (CCT) (K) 2900 K

Fig. 11.

Fig. 11

Location of lighting fixtures illuminating the TA4 workplace.

Table 9 contains the parameters of lighting luminaires and light sources used to illuminate the room in which the TA4 workplace is located (Fig. 12).

Fig. 12.

Fig. 12

Illuminance isolines in the visual task area TA4.

The calculated value of average illuminance is equal to EAVG = 188 lx. the illuminance uniformity in the visual task area is U0 = 0.12 and the maximum and minimum illuminance values are equal to EMAX = 769 lx and EMIN = 22 lx, respectively (Table 10).

Table 10.

Results of illuminance measurements in the visual task area TA4 in lx.

y (cm) x (cm)
55 115 225 335 445 555 665 775 885 995 1105 1115
55 41 37 49 72 96 126 177 211 158 176 261 157
115 27 33 64 79 97 137 198 244 299 197 299 164
225 29 31 59 76 110 157 202 267 347 225 320 180
335 26 30 65 74 107 153 220 288 373 276 342 245
445 33 36 70 87 101 147 169 275 705 769 467 264
555 28 33 57 74 96 136 147 259 643 691 483 296

TA5 workplace

The last examined workplace was used on a daily basis by a full-time student who used the workplace mainly for educational purposes. The person was right-handed and without any visual impairments. The workplace was located in a rented room with dimensions of 3.7 m × 2.6 m and an area of 9.62 m2. The windows in the room faced west. The location of the building is shown in Fig. 13. The workplace was a desk with dimensions of 1.2 m × 0.6 m. The location of the workplace and light points is shown in Fig. 14.

Fig. 13.

Fig. 13

Location of the building in relation to the cardinal directions where the workplace marked as TA5 is located.

Fig. 14.

Fig. 14

Location of lighting luminaires illuminating the TA5 workplace.

The lighting was provided by two lamps. One of them was located next to the desk and a chandelier was installed in the central part of the room. Table 11 contains the parameters of lighting fixtures and light sources used to illuminate the room in which the TA5 workplace is located (Table 12).

Table 11.

List of parameters of lighting fixtures and light sources used to illuminate the room in which the TA5 workplace is located.

Free-standing floor lamp
Location (length and width in the room) 310 cm × 20 cm
The used light source LED source
Power of the light source 6 W
Supply voltage 230–240 V AC
The frequency of the supply voltage 50–60 Hz
Luminous flux (lm) 550
Color temperature (CCT) (K) 5300
Additional features Three-stage lamp dimmable
Chandelier
Location (length and width in the room) 180 cm × 130 cm
Light source used LED Arcchio
Power of the light source 7 W
Supply voltage 230—240 V
The frequency of the supply voltage 50—60 Hz
Luminous flux (lm) 700
Color Temperature (CCT) (K) 3000

Table 12.

Results of illuminance measurements in the visual task area TA5 in lx.

y
(cm)
x (cm)
55 115 225 335 445 555 665 775 885 995 1105 1115
55 140 168 194 245 324 258 267 277 292 272 184 122
115 157 177 208 228 275 292 304 312 386 506 369 124
225 148 203 247 300 326 402 447 482 489 703 541 286
335 134 187 289 337 416 473 595 649 719 788 840 382
445 122 226 345 356 453 563 685 729 851 1080 1078 411
555 116 270 326 403 382 475 512 564 660 924 816 342

The value of average illuminance in the TA5 workplace is EAVG = 405 lx. The maximum and minimum values of illuminance are EMAX = 1080 lx and EMIN = 116 lx, respectively. The calculated value of the illumination uniformity in the visual task area is equal to 0.29 (Fig. 15).

Fig. 15.

Fig. 15

Illuminance isolines in the visual task area TA5.

Discussion

The obtained results of measurements and analysis of lighting parameters are shown in Table 13 and are compared with the requirements of the standard 31.

Table 13.

Comparison of measured and calculated lighting parameters with the requirements of the standard31.

Workplace
(Task area)
Standard requirement
EN 12,464–1:2021
Measurement results Meeting requirements
EAVE (lx) U0 EAVE (lx) U0
TA1 500 0.6 444 0.33 No
TA2 356 0.39 No
TA3 378 0.30 No
TA4 187 0.12 No
TA5 405 0.29 No

The obtained results of lighting parameters measurements were made for selected areas of the workplaces in the private premises. None of the analyzed places met the required lighting parameters for workplaces. Particularly for the TA4 area, the obtained results deviate the most from the required values (the uniformity obtained from the analysis of the measurement results was several times lower than the value derived from the requirements). To ensure high methodological rigor, the total expanded uncertainty of the in situ measurements was estimated from 5 to 12%. This value accounts for device-specific errors (Class B luxmeter), spectral mismatch, and operator positioning in constrained domestic spaces. However, since the recorded illuminance deficits in critical cases (e.g., TA4) exceeded the requirements by over 80%, this margin of uncertainty does not alter the fundamental conclusion of non-compliance with EN 12,464–131

From a physiological perspective, such deep deficits are not merely administrative violations but active health stressors. The extremely low illuminance observed in TA4 (Emin ≈ 22 lx) forces the user’s visual system to operate near the mesopic range. Under these conditions, the pupil dilates significantly to capture more light, which reduces the depth of field. Consequently, the ciliary muscles must exert continuous, excessive effort to maintain focus on the screen, leading to rapid onset of asthenopia and tension headaches. In countries like Germany, where employers rely on self-declarations via photographs, critical photometric deficiencies, such as the ~ 22 lx minimum illuminance found in TA4 cannot be detected. A photograph may show a desk lamp, but it cannot accurately measure the lack of uniformity (U0 ~ 0.12).

In jurisdictions like Portugal, the requirement for a 24-h notice before inspection allows for temporary workspace adjustments that may not reflect daily reality. This further complicates the employer’s ability to identify long-term health stressors like the insufficient circadian stimulus found in TA4 due to warm light sources (≈ 2900 K). As noted in the introduction, lack of high-intensity, cool-spectrum light during the day may disrupt melatonin suppression, potentially leading to daytime somnolence and delayed sleep phase syndrome in remote workers19,46,50.

Relatively the best results of lighting parameters were obtained for the TA1 and TA5 workplaces, but even there the obtained results, especially the uniformity of illumination, are almost twice less than the expected values.

For workplaces used in private homes during remote work, there should be the same requirements for lighting parameters as for workplaces located in companies. This “technical enforcement gap” demonstrates that even with explicit intent, professional tools such as maintenance factors and photometric files are non-transferable to the domestic sphere. The conflict is further amplified in models like Italy’s ‘Lavoro Agile’, where the ‘right to disconnect’ creates a legal barrier to monitoring OHS compliance outside designated hours, effectively leaving the home office as an unmonitored environment. In companies, occupational health and safety officers are responsible for ensuring the proper workplace lighting requirements are met. They can perform the relevant illuminance measurements themselves (if they have the necessary knowledge and skills) or outsource them to an external company. In the case of a private home workplace, there are several problems. Firstly, the workplace is located inside a private property, so if the employer wants to outsource the measurements to a professional company or have an employee from the health and safety department who can perform the measurements, then the consent of the property owner would be required. The employer would have to force the employee to modify the lighting at his property if he was found to be in non-compliance with the current regulations, but it is highly debatable whether the employee would consent to such action. Arrangements for lighting and non-lighting requirements for workplaces where work is performed remotely can be regulated by an appropriate agreement between the employer and the employee. Another issue is the cost of lighting modernization.

If an occupational disease is found to be related to, for example an eye injury, who is liable? An employee who lacks knowledge of workplace lighting, or an employer who, by outsourcing remote work, failed to ensure proper working conditions. The solution to this problem is education and the proper information should be written in the employment contract.

The place of performing remote work is indicated by the employee but must be approved by the employer. Typically, this is the employee’s residence, though not necessarily. For instance, within the analyzed jurisdiction (Poland), according to Article 207 of the Polish Labour Code, the employer remains responsible for ensuring safety and hygiene, even in remote settings, despite their limited ability to control the home environment. Employees, in turn, are obliged to follow employer-provided training and guidelines regarding proper workstation setup.

Even before the pandemic, for example, home schoolers were doing this work at home. Their workplaces usually were not and are not adequately lit. This is primarily due to a lack of knowledge regarding workplace lighting. According to the authors, education on workplace lighting should be carried out from the beginning of education. Education should include the effects of lighting on living organisms including the effects of blue light, measurements and methods of assessing it, and the basic parameters of light sources and luminaires.

The most accurate results of illuminance measuring are obtained using a calibrated luxmeter. An employee or normal property user cannot be required to purchase such a device.

Considering the legal restrictions preventing employers from conducting physical inspections in private residences, ensuring visual comfort largely becomes the responsibility of the employee. However, most remote workers lack access to professional photometric equipment. To address this gap, Table 14 presents a simplified self-assessment checklist. This protocol was developed directly based on the critical deficiencies and ergonomic errors identified in the analyzed case studies (TA1–TA5). It allows for the rapid identification of visual hazards such as the lack of task lighting observed in TA4 or the shadowing issues pertinent to left-handed users in TA3 without the need for specialized instrumentation. It serves as a bridge for this regulatory gap. It respects the privacy laws of the EU and the liberal stance of the USA while providing a non-invasive method to mitigate the “compliance gap” where visual safety currently shifts entirely to the employee.

Table 14.

Simplified self-assessment checklist for home office visual ergonomics, derived from critical deficiencies identified in case studies TA1–TA5.

Category Assessment question (Checkpoint) Basis in case study (Risk identified) Corrective action
1. Illuminance Level Is there a dedicated task lamp directed specifically at the desk surface? TA4: Lack of effective task lighting resulted in critical underexposure (EAVG ≈ 188 lx, EMIN ≈ 22 lx) Install a desk lamp with adjustable arm. Ceiling lighting alone is insufficient for visual tasks
2. Directionality & Handedness Is the light source positioned on the side opposite to the dominant hand? TA2, TA3: Multi-user desks and left-handed users are prone to “shadow casting” if lighting geometry is not personalized

Right-handed: Place lamp on the Left

Left-handed: Place lamp on the Right

3. Uniformity & Contrast Is the area surrounding the visual task (monitor/paper) moderately illuminated, avoiding deep darkness? TA1, TA5: Low uniformity (U0 ≈ 0.3) causes high contrast ratios, forcing frequent eye accommodation and fatigue Introduce “background lighting” (e.g., LED strip or wall lamp) behind the monitor to reduce contrast between the bright screen and dark room
4. Glare Control Is the light source positioned to avoid direct visibility of the light source and reflections on the monitor screen? TA5: Small room dimensions (9.6 m2) increase the risk of reflections on screens from central lighting Adjust the lamp head angle. Use blinds to control daylight entering from windows facing the screen
5. Light Source Quality Is the Color Correlated Temperature (CCT) appropriate for work (neutral/cool white)? TA4, TA5: Use of warm sources (CCT < 3000 K) may promote relaxation rather than alertness required for cognitive tasks Replace light source with Neutral White (CCT ≈ 4000 K) sources for working hours to support concentration

However, in the case of companies, it is possible to allow employees to borrow such a device, after completing appropriate training or at the employee’s request, the company where they are employed will perform the measurements and assessment. In the case of individuals, this is a more complicated situation. They can use the knowledge available, e.g. in books, on the Internet and mobile applications for measuring illuminance. Unfortunately, in the case of mobile applications, their user does not know what measurement error is being performed and is not sure whether the measurement is being correctly performed.

Another problem is that both government agencies and the European Union are conducting extensive education on energy efficiency, which is usually understood as a reduction in electricity consumption for lighting purposes. The primary purpose of lighting is to provide the best possible lighting conditions for work as well as to relax. By reducing the power of the sources, i.e. the consumption of electrical energy, the luminous flux can be simultaneously reduced. Reducing the luminous flux can affect the illumination and its uniformity. This relationship is valid not only for the luminous flux, but also for the luminous intensity distribution. For an ordinary user—customer, the concept of the luminous intensity distribution is unknown. When choosing a light source or lighting fixture, customers are guided primarily by two criteria—price and power. The lower these parameters, the more attractive the product is. In many cases, however, misunderstandings occur and after purchase and installation, it turns out that the customer prefers a warm colour (2700 K) and has purchased a light source with a corelated colour temperature CCT, for example 4000 K. Another important parameter that is placed on the label of a light source or lighting fixture is the color rendering index. The average user does not know what it means and what value is required to perform a given visual task.

This study has certain limitations. By focusing on artificial lighting in an in situ “worst-case scenario”, it does not account for the benefits of daylight or long-term maintenance factors.

Finally, several limitations of this study should be acknowledged. Firstly, the research is based on a selected case series of five diverse home-office configurations. While these scenarios capture the most common makeshift and dedicated workspace types, they do not represent a statistically exhaustive survey of the entire remote-working population. Secondly, the analysis focused exclusively on artificial lighting to evaluate the ‘worst-case scenario’ for OHS compliance; thus, the mitigating effects of natural daylight during daytime hours were not quantified. Lastly, the ‘in situ’ nature of the measurements in private residences precluded a detailed technical audit of the lighting hardware (e.g., precise luminous flux degradation or age of the luminaires), focusing instead on the actual illuminance levels delivered to the user’s visual task area. However, this methodological choice was necessary to highlight the immediate legal and safety risks inherent in the unregulated home-office environment.

Conclusions

The main contribution of this study to the existing body of research is twofold. First, unlike previous studies that predominantly focus on subjective worker comfort or theoretical simulations, this research provides empirical, objective in situ data on the actual lighting conditions in remote workspaces. Second, it establishes a novel interdisciplinary link between technical non-compliance and the „Privacy-Safety Paradox”. While previous literature has identified ergonomic challenges in home offices, this study contributes a comparative legal-technical analysis that explains the systemic inability to enforce occupational safety standards within the private domestic sphere, thereby identifying a critical regulatory gap in modern labor frameworks. The paper presents the results of measurements of lighting parameters for selected work areas marked from TA1 to TA5. The measurements were performed for visual task areas, where the size of the calculation grid was determined the following requirements included in the EN 12,464–1 standard31. For the analyzed areas, the average illuminance in the visual task area should be 500 lx. Unfortunately, in none of the analyzed cases, the obtained lighting parameters are considered to meet the normative requirements. Especially for the analyzed areas marked as TA4 and TA5, the obtained value of lighting uniformity significantly deviates from the standard.

This systemic failure is intrinsically linked to the "Privacy-Safety Paradox" identified in the legal analysis, where the inviolability of the home protected by statutes such as the German Basic Law (Art. 13 Grundgesetz) or the Polish Labour Code effectively prevents employers from conducting necessary physical audits. Consequently, even in jurisdictions with modern remote work frameworks, such as Portugal and France, reliance on self-declarations and virtual inspections is insufficient to detect critical ergonomic hazards, including the extreme underexposure (Emin ≈ 22 lx) and poor uniformity (U0 ≈ 0.12) identified in TA4.

Although lighting conditions were somewhat better in the remaining cases, they still cannot be considered comfortable. Long-term work in such poorly lit environments may result in discomfort, reduced well-being, and, in the long run, irreversible damage to vision.

These results are particularly relevant today, as remote work has become a standard practice for many employers and employees, transforming private living spaces into permanent workplaces. While large organizations typically have units responsible for occupational health and safety, employees working from home must often assess and manage their own working conditions – including lighting.

The research identifies a systemic regulatory gap where constitutional privacy protections (e.g., Art. 13 Grundgesetz in Germany) outweigh the employer’s duty to conduct physical audits. To bridge this gap, future legislation should focus on defining the ‘occupational micro-environment’ within the home. Future legislation should focus on defining the ‘occupational micro-environment’ within the home to allow for targeted ergonomic interventions without compromising the inviolability of the entire residence.

Although this study focuses on lighting ergonomics, the authors recognize that a comprehensive assessment of remote work safety must also consider organizational and psychosocial factors, such as time pressure, the presence of other household members, and the quality of the indoor environment (ventilation, noise), which is an important direction for future interdisciplinary research.

The findings of this study pave the way for several promising avenues of future research. Firstly, expanding the current case series into a large-scale, multi-center statistical survey would provide a more comprehensive map of lighting ergonomics across different demographics. Secondly, further interdisciplinary research is needed to evaluate the role of “smart-lighting” and IoT (Internet of Things) solutions in bridging the compliance gap. Such systems could potentially ensure normative illuminance levels automatically, mitigating the lack of professional oversight. Additionally, longitudinal clinical studies could correlate the identified technical deficiencies with long-term health outcomes, such as digital eye strain or circadian rhythm disruption among remote workers. Finally, from a legal perspective, future work should explore the feasibility of ‘remote ergonomic auditing’ frameworks, where digital tools could provide verified evidence of compliance while respecting the constitutional inviolability of the home.

Consequently, despite stringent occupational safety laws in the EU and the varied regulatory approaches in the USA, the responsibility for visual health in remote work has largely shifted to the individual. The study proves that without the right to disconnect being balanced with safety education, as seen in the Italian model, the worker remains at risk. Instead of unenforceable physical inspections, we recommend the implementation of simplified self-assessment tools, such as the checklist proposed in this study, to empower workers to identify hazards like poor uniformity (U0 ≈ 0.12) independently.

The implementation of such non-invasive tools is essential to respect the privacy laws of the EU while mitigating the liability trap that currently affects both employers and employees.

Finally, the findings of this study suggest that the technical and legal challenges of remote work lighting must be re-evaluated through the lens of public health. When a significant percentage of the population transitions to home-based work without adequate ergonomic oversight, individual occupational hazards scale up to collective public health issues. Prolonged exposure to sub-standard illuminance and poor uniformity (as evidenced in our case studies) contributes to the prevalence of computer vision syndrome (CVS), circadian rhythm disruptions, and cumulative eye strain across the workforce. Therefore, bridging the „compliance gap” is not only a matter of employer liability but a necessary intervention to prevent a long-term decline in visual and mental well-being at the population level. Integrating OHS standards with public health initiatives may be the only viable path to ensuring that the digital transformation of work does not result in a systemic health deficit.

Author contributions

Conceptualisation, R.S., E.K. and P.M.; methodology, R.S., E.K. and P.M.; validation, R.S., E.K. and P.M.; investigation, R.S., E.K., P.M., A.S. and M.S.; writing—original draft preparation, R.S., E.K. P.M. and M.S.; writing—review and editing, R.S., E.K. and P.M.; supervision, R.S. and E.K. All authors have read and agreed to the published version of the manuscript.

Data availability

Data are contained within the article.

Declarations

Competing interests

The authors declare no competing interests.

Ethics approval and consent to participate

Not applicable. The study did not involve human subjects, human tissue samples, or clinical/biological experiments. Technical, physical measurements of lighting parameters were conducted in situ. Consent was obtained from property owners only to access the premises for technical lighting measurements. Formal ethical approval from an institutional bioethics committee was not required.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Roman Sikora and Ewa Korzeniewska have contributed equally to this work.

References

  • 1.European Foundation for the Improvement of Living and Working Conditions: Report “Living and working in Europe 2020 YEARBOOK”. https://www.eurofound.europa.eu/en/publications/all/living-and-working-europe-2020 (accessed online 15 February 2026).
  • 2.Li, Q., Long, R., Chen, H., Chen, F. & Wang, J. Visualized analysis of global green buildings: development, barriers and future directions. J. Clean. Prod.245, 118775. 10.1016/j.jclepro.2019.118775 (2020). [Google Scholar]
  • 3.WHO. Considerations for Quarantine of Contacts of COVID-19 Cases 7 (World Heal. Organ., 2021). [Google Scholar]
  • 4.Freire-Gonz´alez, J., Vivanco, D.F. Pandemics and the environmental rebound effect: reflections from COVID-19, Environ. Resour. Econ. 1–4 (2020) [DOI] [PMC free article] [PubMed]
  • 5.Fezi, B. A. Health engaged architecture in the context of COVID-19. J. Green Build.15(2), 185–212 (2020). [Google Scholar]
  • 6.J. Honey-Roses, I. Anguelovski, J. Bohigas, V. Chireh, C. Daher, C. Konijnendijk, J. Litt, V. Mawani, M. McCall, A. Orellana, E. Oscilowicz, The Impact of COVID-19 on Public Space: a Review of the Emerging Questions. 10.31219/osf.io/rf7xa (2020).
  • 7.Narayanamurthy, G. & Tortorella, G. Impact of COVID-19 outbreak on employee performance – Moderating role of industry 4.0 base technologies. Int. J. Prod. Econ.234, 108075. 10.1016/j.ijpe.2021.108075 (2021). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Young, E. Homes’ Influance on Mental Health Boosts Architectures’ Value (RIBA, 2020). [Google Scholar]
  • 9.Cuerdo-Vilches, T., Navas-Martín, M. Á. & Oteiza, I. A mixed approach on resilience of Spanish dwellings and households during covid-19 lockdown. Sustain12, 1–24. 10.3390/su122310198 (2020). [Google Scholar]
  • 10.Blume, C., Schmidt, M. H. & Cajochen, C. Effects of the COVID-19 lockdown on human sleep and rest-activity rhythms. Curr. Biol.30(14), R795–R797. 10.1016/j.cub.2020.06.021 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Bergefurt, L., Weijs-Perrée, M., Appel-Meulenbroek, R. & Arentze, T. The physical office workplace as a resource for mental health – A systematic scoping review. Build. Environ.207, 108505. 10.1016/j.buildenv.2021.108505 (2022). [Google Scholar]
  • 12.Singh, A., Syal, M., Grady, S. C. & Korkmaz, S. Effects of green buildings on employee health and productivity. Am. J. Public Health100, 1665–1668 (2010). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Douglas, I. P. et al. Physical workplaces and human well-being: A mixed-methods study to quantify the effects of materials, windows, and representation on biobehavioral outcomes. Build. Environ.224, 109516. 10.1016/j.buildenv.2022.109516 (2022). [Google Scholar]
  • 14.Altena, E. et al. Dealing with sleep problems during home confinement due to the reco-19 outbreak: practical recommendations from a task force of the European CBT-I Academy. J. Sleep Res.29, e13052 (2020). [DOI] [PubMed] [Google Scholar]
  • 15.van Hoof, J., Bennetts, H., Hansen, A., Kazak, J. K. & Soebarto, V. The living environment and thermal behaviours of older south Australians: a multi-focus group study. Int. J. Environ. Res. Publ. Health16, 935 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Yu, H. & Akita, T. Effects of illuminance and color temperature of a general lighting system on psychophysiology while performing paper and computer tasks. Build. Environ.228, 109796. 10.1016/j.buildenv.2022.109796 (2023). [Google Scholar]
  • 17.Deng, M., Wang, X. & Menassa, C. C. Measurement and prediction of work engagement under different indoor lighting conditions using physiological sensing. Build. Environ.203, 108098. 10.1016/j.buildenv.2021.108098 (2021). [Google Scholar]
  • 18.Konstantzos, I., Sadeghi, S. A., Kim, M., Xiong, J. & Tzempelikos, A. The effect of lighting environment on task performance in buildings – A review. Energy Build.226, 110394. 10.1016/j.enbuild.2020.110394 (2020). [Google Scholar]
  • 19.Obayashi, F. et al. Development of an illumination control method to improve office productivity. In Symposium on Human Interface and the Management of Information 939–947 (Springer, 2007). [Google Scholar]
  • 20.Ricketts, E. J. et al. Electric lighting, adolescent sleep and circadian outcomes, and recommendations for improving light health. Sleep Med. Rev.64, 101667. 10.1016/j.smrv.2022.101667 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Webb, A. R. Considerations for lighting in the built environment: Non-visual effects of light. Energy Build.38(7), 721–727 (2006) (Special Issue on Daylighting Buildings.). [Google Scholar]
  • 22.Yeom, S., Kim, H., Hong, T., Park, H. S. & Lee, D. E. An integrated psychological score for occupants based on their perception and emotional response according to the windows’ outdoor view size. Build. Environ.10.1016/j.buildenv.2020.107019 (2020). [Google Scholar]
  • 23.Boyce, P. R. Human Factors in Lighting third ed. (CRC Press Taylor & Francis Group, 2014). [Google Scholar]
  • 24.Altomonte, S. et al. Ten questions concerning well-being in the built environment. Build. Environ.180, 106949 (2020). [Google Scholar]
  • 25.Blocken, B. et al. Can indoor sports centers be allowed to re-open during the COVID-19 pandemic based on a certificate of equivalence?. Build. Environ.10.1016/j.buildenv.2020.107022 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Cvetković, D., Nešović, A. & Terzić, I. Impact of people’s behavior on the energy sustainability of the residential sector in emergency situations caused by COVID-19. Energy Build.230, 110532. 10.1016/j.enbuild.2020.110532 (2021) (ISSN 0378-7788). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Xue, P., Mak, C. M. & Cheung, H. D. The effects of daylighting and human behavior on luminous comfort in residential buildings: A questionnaire survey. Build. Environ.81, 51–59 (2014). [Google Scholar]
  • 28.Wirz-Justice, A., Skene, D. J. & Münch, M. The relevance of daylight for humans. Biochem. Pharmacol.191, 114304. 10.1016/j.bcp.2020.114304 (2021). [DOI] [PubMed] [Google Scholar]
  • 29.Fontoynont, M. Daylight Performance of Buildings (Earthscan/Routledge, 2014). 10.4324/9781315073743. [Google Scholar]
  • 30.Knoop, M. et al. Daylight: What makes the difference?. Light. Res. Technol.52(3), 423–442. 10.1177/1477153519869758 (2020). [Google Scholar]
  • 31.EN 12464–1: Light and lighting-Lighting of work places-Part 1: Indoor work places (2021).
  • 32.Vasquez, N. G., Rupp, R. F., Andersen, R. K. & Toftum, J. Occupants’ responses to window views, daylighting and lighting in buildings: A critical review. Build. Environ.219, 109172. 10.1016/j.buildenv.2022.109172 (2022). [Google Scholar]
  • 33.Sokol, N. et al. Personas for lighting’ Three methods to develop personas for the indoor lighting environment. Energy Build.278, 112580. 10.1016/j.enbuild.2022.112580 (2023). [Google Scholar]
  • 34.Wang, Q., Xu, H., Zhang, F. & Wang, Z. Influence of color temperature on comfort and preference for LED indoor lighting. Optik129, 21–29. 10.1016/j.ijleo.2016.10.049 (2017). [Google Scholar]
  • 35.Smolders, K. C. H. J. & de Kort, Y. A. W. Investigating daytime effects of correlated colour temperature on experiences, performance, and arousal. J. Environ. Psychol.50, 80–93. 10.1016/j.jenvp.2017.02.001 (2017). [Google Scholar]
  • 36.Zoubi, M. K., Rashidi, A., Ali AL-Alawneh, W., Issa, M. M. & Alqamaz, S. The influence of light colour temperatures on interior design student performance in classroom studies. Civ. Eng. Archit.12(1), 61–69. 10.13189/cea.2024.120105 (2024). [Google Scholar]
  • 37.Giraldo Vasquez, N. et al. Lighting conditions in home office and occupant’s perception: Exploring drivers of satisfaction. Energy Build.261, 111977. 10.1016/j.enbuild.2022.111977 (2022). [Google Scholar]
  • 38.Doling, J. & Arundel, R. The home as workplace: A challenge for housing research. Housing Theory Soc.39(1), 1–20. 10.1080/14036096.2020.1846611 (2022). [Google Scholar]
  • 39.Wu, H., Chang, Y. & Chen, Y. Greenhouse gas emissions under work from home vs. office: An activity-based individual-level accounting model. Appl. Energy353, 122167. 10.1016/j.apenergy.2023.122167 (2024) (Part B). [Google Scholar]
  • 40.Safranek, S., Collier, J. M., Wilkerson, A. & Davis, R. G. Energy impact of human health and wellness lighting recommendations for office and classroom applications. Energy Build.226, 110365. 10.1016/j.enbuild.2020.110365 (2020). [Google Scholar]
  • 41.Xia, B. & Li, Z. Optimization of residential urban-block morphology based on its synthetic effects on indoor and outdoor natural lighting environments. Sustain. Cities Soc.97, 104698. 10.1016/j.scs.2023.104698 (2023) (ISSN 2210-6707). [Google Scholar]
  • 42.Samiou, A. I., Doulos, L. T. & Zerefos, S. Daylighting and artificial lighting criteria that promote performance and optical comfort in preschool classrooms. Energy Build.258, 111819. 10.1016/j.enbuild.2021.111819 (2022). [Google Scholar]
  • 43.Mantesi, E., Chmutina, K. & Goodier, C. The office of the future: Operational energy consumption in the post-pandemic era. Energy Res. Soc. Sci.87, 102472. 10.1016/j.erss.2021.102472 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Ferreira de Souza, D., Fernandes da Silva, P. P., Almeida Fontenele, L. F., Damaceno Barbosa, G. & de Oliveira Jesus, M. Efficiency, quality, and environmental impacts: A comparative study of residential artificial lighting. Energy Rep.5, 409–424. 10.1016/j.egyr.2019.03.009 (2019). [Google Scholar]
  • 45.Naves, C. et al. Lighting conditions in home office and occupant’s perception: An international study. Energy Build.261, 111957. 10.1016/j.enbuild.2022.111957 (2022). [Google Scholar]
  • 46.Pompei, L., Blaso, L., Fumagalli, S. & Bisegna, F. The impact of key parameters on the energy requirements for artificial lighting in Italian buildings based on standard EN 15193-1:2017. Energy Build.263, 112025. 10.1016/j.enbuild.2022.112025 (2022). [Google Scholar]
  • 47.Bournas, I. & Dubois, M. C. Residential electric lighting use during daytime: A field study in Swedish multi-dwelling buildings. Build. Environ.10.1016/j.buildenv.2020.106977 (2020). [Google Scholar]
  • 48.Wall, R. T. Crosbie Potential for reducing electricity demand for lighting in households: an exploratory socio-technical study. Energy Pol.37(3), 1021–1031 (2009). [Google Scholar]
  • 49.C.F. Chen, G.Z. de Rubens, X. Xu, J. Li, Coronavirus comes home? Energy use, home energy management, and the social-psychological factors of COVID-19, Energy Res. Soc. Sci., 101688. (2020). [DOI] [PMC free article] [PubMed]
  • 50.Despenic, M., Chraibi, S., Lashina, T. & Rosemann, A. Lighting preference profiles of users in an open office environment. Build. Environ.116, 89–107. 10.1016/j.buildenv.2017.01.033 (2017). [Google Scholar]
  • 51.Gerhardsson, K. M. & Laike, T. User acceptance of a personalised home lighting system based on wearable technology. Appl. Ergon.96, 103480. 10.1016/j.apergo.2021.103480 (2021). [DOI] [PubMed] [Google Scholar]
  • 52.de Vries, A., Souman, J. L., de Ruyter, B., Heynderickx, I. & de Kort, Y. A. W. Lighting up the office: The effect of wall luminance on room appraisal, office workers’ performance, and subjective alertness. Build. Environ.142, 534–543. 10.1016/j.buildenv.2018.06.046 (2018). [Google Scholar]
  • 53.Gentile, N. et al. Evaluation of integrated daylighting and electric lighting design projects: Lessons learned from international case studies. Energy Build.268, 112191. 10.1016/j.enbuild.2022.112191 (2022). [Google Scholar]
  • 54.Wolska, A. & Sawicki, D. Practical application of HDRI for discomfort glare assessment at indoor workplaces. Measurement151, 107179. 10.1016/j.measurement.2019.107179 (2020). [Google Scholar]
  • 55.Wang, Y., Yang, W. & Wang, Q. Multi-objective parametric optimization of the composite external shading for the classroom based on lighting, energy consumption, and visual comfort. Energy and Buildings275, 112441. 10.1016/j.enbuild.2022.112441 (2022). [Google Scholar]
  • 56.Allan, A. C., Garcia-Hansen, V., Isoardi, G. & Smith, S. S. Subjective assessments of lighting quality: A measurement review. Leukos15(2–3), 115–126. 10.1080/15502724.2018.1531017 (2019). [Google Scholar]
  • 57.Ulrich, R. View through a window may influence recovery from surgery. Science27(224), 420–421 (1984). [DOI] [PubMed] [Google Scholar]
  • 58.Fekry, S. A., Hosny, S. S., Sabry, H. & Fathy, F. Lighting impact on stress reduction: A study of correlated color temperature in workplace design utilizing neuroarchitecture principles. Build. Environ.278, 112972. 10.1016/j.buildenv.2025.112972 (2025). [Google Scholar]
  • 59.Zhao, X. et al. Predictive modeling of office lighting comfort: Interactive effects of illuminance and color temperature on EEG and cognitive workload. Journal of Building Engineering118, 115023. 10.1016/j.jobe.2025.115023 (2026). [Google Scholar]
  • 60.Li, Y. et al. Bridging photometric parameters and emotional well-being: Validating the atmosphere perception scale to optimize illuminance and CCT interactions in occupational lighting. Build. Environ.10.1016/j.buildenv.2025.113533 (2025).41312418 [Google Scholar]
  • 61.Heidari, B., Abravesh, M. & Khodabakhshian, M. Human-centric lighting in office spaces: Daylight strategies and environmental influences on visual effects and circadian health. Build. Environ.10.1016/j.buildenv.2025.113538 (2025). [Google Scholar]
  • 62.OSHA Directive CPL 02–00–125 – Home-Based Worksites Policy, United States.
  • 63.Grundgesetz für die Bundesrepublik Deutschland (Basic Law), Article 13: Inviolability of the home; Arbeitsstättenverordnung (ArbStättV)
  • 64.French Labor Code (Code du travail), Article L1222–9 to L1222–11 regarding telework.
  • 65.Portuguese Labor Code (Código do Trabalho), Articles 165–171 (Remote Work Law 2021), Lei No 7/2009.
  • 66.Italian Law No. 81/2017 (Lavoro Agile framework) and the "Right to Disconnect".
  • 67.Belgian Code of Well-being at Work, Book VI, Title 2 regarding Visual Display Unit Equipment (VDU).
  • 68.Dutch Working Conditions Decree (Arbeidsomstandighedenbesluit), Section "Analysis of lighting conditions of workplaces": Special requirements for telework, Article 5.12.
  • 69.Council Directive 89/391/EEC of 12 June 1989 on the introduction of measures to encourage improvements in the safety and health of workers at work (entered into force on 19 June 1989).
  • 70.Council Directive 89/654/EEC of 30 November 1989 concerning the minimum safety and health requirements for the workplace.
  • 71.Charter of Fundamental Rights of the European Union, Article 7: Respect for private and family life (2012/C 326/02).
  • 72.Act of 26 June 1974 – Polish Labour Code, Art. 67(28) and Art. 207. Journal of Laws - Uniform text No 277/2025
  • 73.EN 13032 standard - Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

Data are contained within the article.