. 2026 Aug 20;18:604910. doi: 10.2147/CCIDE.S604910

Degradation of the Strength of Elastomeric Chains Exposed to Energy Drinks in a Simulated Oral Environment

Fernanda-Elizabeth Quezada-Calle 1, Miriam Lima-Illescas 1,2,3, Katherine Cuenca-León 1,2,3, Edisson-Mauricio Pacheco-Quito 1,2,3,✉
PMCID: PMC13502321  PMID: 42639543

Abstract

Objective

This study was conducted to evaluate the degradation of strength in memory elastomeric chains after repeated exposure to different energy drinks under simulated oral cavity conditions.

Methods

The study included 180 memory elastomeric chains from three commercial brands. Their initial strength was measured at six time points after daily immersion in energy drinks. A descriptive analysis was performed, and the assumptions of repeated-measures ANOVA were verified. ANOVA was then applied to evaluate the variation in strength according to brand and immersion solution, followed by Tukey’s post-hoc test (p<0.05).

Results

The decrease in strength of various brands of elastomeric chains intensified over time, following a similar decay pattern. The elastomeric chains lost approximately 46% of their initial strength after 28 days of immersion in an energy drink, compared to a loss of 43% in the control group. Among the manufacturers evaluated, one group exhibited the greatest resistance to force degradation.

Conclusion

Considering the effects of manufacturer, duration, and type of energy drink, exposure to these beverages significantly accelerates force degradation in elastomeric chains. These findings support limiting the consumption of energy drinks during orthodontic treatment or selecting materials with greater resistance to force degradation.

Keywords: strength decay, elastomeric chains, in vitro, simulated oral environment

Introduction

Elastomeric chains (ECs) are some of the main devices for the application of force in contemporary orthodontics and are widely used in procedures such as space closure and canine traction. Manufactured predominantly from polyurethane, these chains offer significant clinical advantages, including their low cost and ease of use and manipulation independent of patient cooperation.1,2 However, these advantages are offset by a progressive and significant loss of applied force, a phenomenon inherent to the viscoelastic nature of the material, which can compromise biomechanical efficiency and the predictability of orthodontic treatment, particularly given that orthodontic therapy relies on the application of light, continuous, and controlled forces is essential to achieve efficient and biologically safe tooth movement; therefore, force degradation may directly affect treatment outcomes and duration. When exposed to the oral environment, elastomeric chains (ECs) initially exhibit elastic deformation, followed by irreversible plastic deformation, which results in a progressive decrease in strength over time. This loss of mechanical performance necessitates periodic replacement avoid functional inactivation of the material. This constitutes a recurring challenge in orthodontic clinical practice and a critical factor in the control of treatment biomechanics.3

In this context, the effectiveness of orthodontic treatments depends largely on the ability of mechanical devices to maintain stable, continuous, and biologically compatible forces over time.4–6 However, numerous studies have shown that the elastic materials used in orthodontics undergo a progressive loss of strength, a phenomenon attributed mainly to water absorption and interaction with salivary components, processes that induce modifications in the molecular structure of the polymer and alter its mechanical behavior.7–12 Additionally, previous research has demonstrated that exposure to chemical agents such as mouthwashes and acidic beverages can significantly influence the mechanical properties and force stability of elastomeric chains, highlighting the importance of evaluating different intraoral environments.13,14

In addition to the intrinsic factors of the oral environment—such as saliva, moisture, and pH variations—patients’ dietary habits play a significant role in the degradation of the mechanical properties of ECs.5,6 In this regard, the consumption of energy drinks has shown a sustained increase in recent years, especially among adolescents and young adults, an age group with a high prevalence of orthodontic treatment.15 This is particularly relevant given that this population is more likely to consume highly acidic and carbonated beverages during orthodontic therapy.

Studies have reported that energy drinks can accelerate the loss of strength of ECs, an effect attributed mainly to their acidic pH (~2.5–4.0) and high content of sugars and additives, as well as the presence of other bioactive components, such as caffeine.9,16 These components have also been described to negatively affect other orthodontic materials by promoting enamel erosion, demineralization, and weakening of bracket adhesion, in addition to causing stains and discoloration of the appliances.17

It has been documented that conventional occlusal clamps can lose between 40% and 60% of their initial strength during the first week of use, compromising tooth movement control and treatment efficiency.18 In response to this limitation, memory ECs were developed to provide a more sustained release of force, maintaining approximately 60% of their initial force after 28 days.19 Compared to conventional chains—which show reductions of around 50% in the first seven days—memory chains show significantly less degradation, close to 20%, allowing for reduced replacement frequency and improved biomechanical control of orthodontic treatment.1 These materials are designed to exhibit enhanced elastic recovery and improved resistance to force decay, making them a promising alternative in clinical orthodontics.

Despite the existing evidence on the effects of saliva, mouthwashes, and acidic beverages on conventional elastomeric chains, the specific impact of energy drinks—characterized by their unique chemical composition—on memory elastomeric chains remains insufficiently explored.13,14

Despite these advantages, specific scientific evidence on the effect of energy drinks on elastomeric chains under conditions simulating the oral environment remains limited. This knowledge gap justifies the need for research aimed at evaluating the impact of energy drinks on these frequently used clinical materials.

Therefore, the aim of this study was to evaluate the degradation of strength in memory elastomeric chains after repeated exposure to different energy drinks under simulated oral cavity conditions. It was hypothesized that ECs exposed to energy drinks would experience a greater loss of strength compared to those not exposed (control group). The results of this study provide evidence that can help optimize clinical decision-making, promote healthy dietary habits in patients, and contribute to the development of orthodontic materials with greater resistance to adverse oral conditions.

Materials and Methods

Elastomeric Chains

This study used 180 short segments of gray memory elastomeric chains, which were selected for their frequent clinical use in orthodontics. Specimens were obtained from the same commercial lots of three internationally recognized brands and were randomly assigned to three groups based on the brand: C1 (TP Orthodontics Inc., La Porte, IN, USA), C2 (Ormco Corporation, Orange, CA, USA), and C3 (American Orthodontics, Sheboygan, WI, USA). This grouping was established to evaluate potential inter-brand variations in the mechanical behavior of elastomeric chains.

Energy Drinks and Control Solution

Two widely consumed energy drinks were evaluated: Beverage A (V220, Pichincha, Ecuador) and Beverage B (Red Bull, Red Bull GmbH, Fuschl am See, Salzburg, Austria). These drinks were selected based on their high availability in local and international markets, their popularity among consumers, and the differences in their chemical composition, particularly in the content of caffeine, sugars, and acidic additives—components potentially involved in the degradation of orthodontic materials. Artificial saliva was used both as a control to simulate the baseline conditions of the oral environment and for storing the samples during the experimental period. The artificial saliva was prepared using a standard formulation containing NaCl (0.4 g/L), KCl (0.4 g/L), CaCl2·2H2O (0.795 g/L), NaH2PO4·2H2O (0.78 g/L), Na2S·9H2O (0.005 g/L), and urea (1 g/L), with a pH adjusted to 7.0.

Equipment

The following equipment was used for measurement and experimental control: a digital dynamometer (Digital Force Gauge, model ZMF-500 N, Imada Inc., Northbrook, IL, USA), with an accuracy of ±0.2% of full scale ±1 digit and a resolution of 0.1 N; an incubation oven (Memmert, Schwabach, Bavaria, Germany); and a pH meter (BOECO, Hamburg, Germany). Prior to data collection, all measuring devices were calibrated according to the manufacturer’s instructions to ensure measurement accuracy.

Methods

Study Design

An in vitro experimental study was conducted under controlled laboratory conditions. Artificial saliva was used to simulate the oral environment and evaluate the mechanical behavior of the ECs under standardized conditions.

Ethical Considerations

This in vitro experimental study did not involve human participants, biological samples, identifiable data, or animals. The study protocol was reviewed and classified as exempt by the Research Ethics Committee of Universidad Católica de Cuenca, Ecuador (Approval code: CEISH-UCACUE-120-2024), as it involved exclusively commercially available orthodontic materials and laboratory-based mechanical testing procedures.

Sample Size

The sample size was determined using a two-proportion comparison test two-media comparison test, referencing the variability and mean differences reported in previous in vitro studies.17 The calculation considered a confidence level of 95%, a statistical power of 80%, a 1 precision, and a variance of 1.33 resulting in 20 20 elastomeric chain specimens per group with a total of 180 samples included in the study.

Experimental Randomization

The 180 specimens were randomly assigned to three groups based on the manufacturer: C1, C2, and C3. The immersion solutions included two types of energy drinks (beverage A and beverage B) and a control (artificial saliva).

Randomization was performed using a computer-generated random sequence to minimize allocation bias. Twenty samples were allocated to each manufacturer/immersion solution combination, ensuring a homogeneous distribution and comparability between groups, thereby strengthening the internal validity of the study. The sample size was consistent with previous in vitro studies, such as that reported by Martínez et al20 who evaluated 180 ECs and documented significant strength losses between brands.

Pilot Test

Prior to the main experiment, a pilot test was carried out using independent specimens that were not included in the final study sample. A total of 18 elastomeric chain specimens (10% of the total sample; two ECs per group) were used to train the research team in the handling of the dynamometer, incubation oven, and pH meter, as well as to standardize the measurement procedures.

Sample Preparation

The ECs were segmented into four-link units, cut from the sixth link, while leaving one link free at each end. For activation, a custom template with pins spaced 30 mm apart was used, corresponding to 50% activation of the initial elastomeric chain length.21

Immersion and Storage Protocol

The chains were immersed once daily in the corresponding energy drink for 120 seconds. Afterward, the samples were rinsed with distilled water to remove residue and simulate the effect of saliva in the oral cavity. Although this approach allows for standardization of the experimental conditions, it is acknowledged that distilled water does not fully replicate the buffering capacity and dynamic cleansing properties of natural saliva. For the duration of this 28-day study, all ECs were stored in artificial saliva at 37 °C.21–23

Force Measurement

The force released by the ECs was recorded in Newtons (N) at six-time intervals: T1 on day 0 (initial), T2 at 24 hours, T3 on day 7, T4 on day 14, T5 on day 21, and T6 on day 28, according to the experimental protocol illustrated in Figure 1. These times were selected based on usual clinical protocol, in which the ECs are replaced approximately every four weeks.10,22

Figure 1.

A flowchart detailing the experimental protocol for elastomeric chains over six time intervals.

Experimental design for measuring strength degradation in elastomeric chains (ECs).

During each measurement, the chains were maintained at a constant length of 30 mm, corresponding to the spacing of the template pins. After each measurement, the dynamometer was zeroed, ensuring the accuracy of the readings. At the end of each measurement day, the chains were remounted, maintaining the same pin spacing (Figure 1).

All measurements were performed by a single trained and calibrated operator to minimize inter-operator variability.

Bias Control

A blinded observer design was not applied; however, standardized data measurement and recording procedures were implemented, and all assessments were performed under identical experimental conditions to minimize variability and the risk of bias.

Statistical Analysis

A descriptive analysis was performed, calculating the mean and standard deviation of the EC strength according to the evaluation time and immersion solution. Data normality was verified using the Shapiro–Wilk test, and the Greenhouse-Geisser test was used for sphericity test (variances of the differences) on elastomeric chains groups. Baseline force values were compared between groups to assess initial equivalence.

For inferential analysis, a two-way repeated measures Analysis of variance (ANOVA) was applied (beverage × time), evaluating the main effects and interactions. ANOVA is a robust test and does not affect the type I error. Additionally, the factor “brand” (C1, C2, C3) was included in the analysis to evaluate its effect and interaction with solution and time. Tukey’s HSD post hoc test was used for comparisons between groups. The significance level was set at p < 0.05. The main effect of the time factor and beverages was estimated using the R-squared.

Additionally, the percentage of force loss relative to the initial force was calculated using the following formula: Force Loss (%) = [(F0 − Ft) / F0] × 100, where F0 corresponds to the initial force (day 0) and Ft corresponds to the force recorded in each interval. The analysis was performed in terms of both absolute residual force (N) and the percentage of force lost, allowing for a more comprehensive interpretation of the mechanical behavior of the ECs. Tables were created in Microsoft Excel® 2024, and statistical processing and graph generation were performed in SPSS® version 25.0.

Results

The average initial strength of the chains and the strength after being placed in the immersion solutions at different study time points were measured. Table 1 shows the mean and standard deviation of the initial strength, which were 8.018±1.744, 5.739±0.398, and 6.140±0.326 for the memory ECs groups C1, C2, and C3, respectively.

Table 1.

Mean and Standard Deviation of Force Decay (N) in Elastomeric Chains Across the Tested Immersion Solutions at Each Study Time Point

T1 T2 T3 T4 T5 T6
Elastomeric
chain
C1 8.018 ± 1.744 7.594 ± 0.988 6.878 ± 1.551 6.227 ± 0.955 5.577 ± 0.076 5.009 ± 0.708
C2 5.739 ± 0.398 4.999 ± 0.572 4.417 ± 0.611 4.053 ± 0.561 3.645 ± 0.446 3.188 ± 0.450
C3 6.140 ± 0.326 5.322 ± 0.426 4.719 ± 0.512 4.120 ± 0.462 3.537 ± 0.378 3.116 ± 0.426
p <0.001* <0.001* <0.001* <0.001* 0.004* 0.025*
Immersion solutions Control 6.871 ± 1.694 6.455 ± 1.468 6.066 ± 1.551 5.407 ± 1.527 4.526 ± 1.453 4.032 ± 1.371
Beverage A 6.489 ± 1.313 5.572 ± 1.274 4.788 ± 1.148 4.298 ± 0.974 3.894 ± 0.863 3.524 ± 0.831
Beverage B 6.536 ± 1.278 5.889 ± 0.937 5.160 ± 0.819 4.950 ± 0.789 4.339 ± 0.729 3.757 ± 0.721
p 0.287 <0.001* <0.001* <0.001* 0.004* 0.025*

Note: Data are presented as mean ± SD. Repeated-measures ANOVA test. *p < 0.05 was considered statistically significant.

Abbreviations: SD, standard deviation.

After being placed in the immersion solutions, the average initial strength was 6.871±1.694 f or the control group, 6.489±1.313 for chains immersed in Beverage A, and 6.536±1.278 for chains immersed in Beverage B.

Repeated-measures ANOVA showed that the chain brand had a statistically significant effect on the strength remaining over time (p < 0.001), particularly at times T1 to T4. Furthermore, a statistically significant interaction was identified between immersion solution and evaluation time (p < 0.001), indicating that the strength degradation pattern differs depending on the immersion solution.

There was a significant main effect of time intervals (p<0.001) with 84.1% (η2 =0.841) of the decline in strength of the elastomeric chains over time explained by this effect. Furthermore, the interaction between time and immersion solutions was also statistically significant (p<0.001) with 9% (η2 =0.090) explaining the degradation of the strength of the elastomeric chains (Table 2).

Table 2.

Interaction Between Immersion Solutions and Resistance Degradation of Elastomeric Chains Across Six-Time Intervals

Test Origin Type III Sum of Squares df Mean Square F p R-Squared
Greenhouse-Geisser Time 1056.181 2.694 391.996 934.979 <0.001* 0.841
Time × Immersion solutions 19.778 5.389 3.670 8.754 <0.001* 0.090
Error (Time) 1999.945 476.903 0.419  

Note: Greenhouse-Geisser correction was applied. *p < 0.05 was considered statistically significant.

Abbreviation: df: degrees of freedom.

Table 3 shows a comparison of the means and standard deviations of strength decline among the three ECs groups across all test solutions and evaluation times. The results show a progressive and statistically significant decrease in strength in all groups over the 28 days of the study (p<0.001), regardless of the type of chain or solution evaluated.

Table 3.

Mean and Standard Deviation of Residual Force in Elastomeric Chains According to Brand, Immersion Solution, and Evaluation Time

T1 T2 T3 T4 T5 T6
Control C1 8.650 ± 0.231 8.428 ± 0.087 8.167 ± 0.084 7.462 ± 0.086 6.493 ± 0.081 5.837 ± 0.093
C2 5.702 ± 0.231 5.228 ± 0.087 4.734 ± 0.084 4.195 ± 0.086 3.574 ± 0.081 3.108 ± 0.093
C3 6.264 ± 0.231 5.709 ± 0.087 5.297 ± 0.084 4.567 ± 0.086 3.512 ± 0.081 3.153 ± 0.093
p <0.001* <0.001* <0.001* <0.001* <0.001* <0.001*
Beverage A C1 7.703 ± 0.231 7.210 ± 0.087 6.249 ± 0.084 5.543 ± 0.086 4.983 ± 0.081 4.519 ± 0.093
C2 5.668 ± 0.231 4.522 ± 0.087 3.830 ± 0.084 3.575 ± 0.086 3.369 ± 0.081 3.085 ± 0.093
C3 6.098 ± 0.231 4.984 ± 0.087 4.287 ± 0.084 3.777 ± 0.086 3.329 ± 0.081 2.969 ± 0.093
p <0.001* <0.001* <0.001* <0.001* <0.001* <0.001*
Beverage B C1 8.093 ± 0.231 7.146 ± 0.087 6.219 ± 0.084 5.677 ± 0.086 5.254 ± 0.081 4.671 ± 0.093
C2 5.848 ± 0.231 5.249 ± 0.087 4.690 ± 0.084 4.392 ± 0.086 3.992 ± 0.081 3.374 ± 0.093
C3 6.059 ± 0.231 5.273 ± 0.087 4.572 ± 0.084 4.018 ± 0.086 3.771 ± 0.081 3.228 ± 0.093
p <0.001* <0.001* <0.001* <0.001* <0.001* <0.001*

Notes: Data are presented as mean ± SD. p-values correspond to comparisons among elastomeric chain brands within each immersion solution and evaluation time point using repeated-measures ANOVA across T1–T6. *p < 0.05 was considered statistically significant.

Abbreviation: SD: standard deviation.

Within the memory ECs group, the highest rate of strength loss compared to the control group at any time was related to Beverage A. In contrast, C1 was the most stable elastomer over time, undergoing less strength degradation.

After four weeks of evaluation, the group of ECs immersed in Beverage A lost 41% of their initial strength, compared to 33% in the control group and 39% in chains immersed Beverage B, with the differences being statistically significant (p<0.001).

Figure 2 shows the percentages of strength loss for group C2, which were similar across the solutions evaluated; however, chains immersed in Beverage A showed a slight increase in degradation, reaching 46%, compared to chains in the other immersion solutions. C3, in contrast, showed the highest percentage of strength degradation, with a 51% loss after immersion in Beverage A, compared to 49% in the control group and 46% after immersion in Beverage B. Additionally, the strength values showed a greater decrease during the first day. This is a well-known phenomenon in elastomers, where a sharp initial decrease is followed by a lower subsequent rate of strength degradation.6,18

Figure 2.

A grouped bar graph showing force degradation across Control, Beverage A and Beverage B for C1, C2 and C3.

Percentage of force degradation according to elastomeric chain brand.

Regarding the control group maintained in artificial saliva, all brands of ECs showed a progressive decrease in strength, albeit of a smaller magnitude, compared to the chains immersed in energy drinks. Likewise, the results show that Beverage A induced a more pronounced degradation in strength than Beverage B, regardless of the commercial brand evaluated.

Figure 3 presents a graphical comparison of the force degradation pattern of the three types of elastomeric chains evaluated across the different immersion solutions over time. Overall, all groups showed a progressive decrease in residual force during the 28-day experimental period, with the most pronounced reduction occurring during the first 24 hours. The degradation pattern varied according to both brand and immersion solution, with chains exposed to Beverage A generally showing greater force loss, while C1 maintained higher residual force values across most evaluation time points. This visual pattern supports the statistical findings regarding the influence of time, immersion solution, and brand on elastomeric chain force degradation.

Figure 3.

A multi line graph showing mean residual force of elastomeric chains C1, C2 and C3 over time. Nine line graphs arranged in 3 columns and 3 rows. Column headers: C1, C2, C3. Row labels at right: Control, Beverage A, Beverage B. Vertical axis label: Mean residual force (N). Vertical axis range shown from 2 to 8. Horizontal axis label: Evaluation time. Horizontal axis categories: T1, T2, T3, T4, T5, T6. Control row: C1 values at T1 to T6 are 9, 8, 8, 7, 6, 6. C2 values are 6, 5, 5, 4, 4, 3. C3 values are 6, 6, 5, 5, 4, 3. Beverage A row: C1 values are 8, 7, 6, 6, 5, 5. C2 values are 6, 5, 4, 4, 3, 3. C3 values are 6, 5, 4, 4, 3, 3. Beverage B row: C1 values are 8, 7, 6, 6, 5, 5. C2 values are 6, 5, 5, 4, 4, 3. C3 values are 6, 5, 5, 4, 4, 3.

Strength reduction in elastomeric chains C1, C2, and C3 over time according to immersion solution. Mean residual force values are shown for each elastomeric chain brand across the six evaluation time points: T1, baseline; T2, 24 hours; T3, 7 days; T4, 14 days; T5, 21 days; and T6, 28 days. Columns represent the elastomeric chain brands C1, C2, and C3, while rows represent the immersion solutions: control, Beverage A, and Beverage B. The numerical indicators inside the boxes correspond to the mean residual force values, expressed in Newtons (N) and rounded to the nearest whole number, for each brand, immersion solution, and time point. The trend lines indicate the progressive force decay observed during the 28-day experimental period.

Table 4 shows a comparative analysis of the commercial brands immersed in each solution; statistically significant differences were evident in most of the evaluated periods (T1-T6). In the control group, highly significant differences (p<0.05) were identified between the three brands at virtually all time points, demonstrating that even without exposure to external agents, the materials exhibit distinct mechanical behaviors in terms of strength retention.

Table 4.

Pairwise Comparison of p-values for Force Decay Among Elastomeric Chain Brands Over Time According to Immersion Solution

Control Beverage A Beverage B
T1 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 0.258 0.360 0.777
T2 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 <0.001* 0.010 0.962
T3 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 <0.001* 0.006 0.485
T4 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 0.016 0.259 0.003
T5 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 0.868 0.940 0.081
T6 C1 C2 <0.001* <0.001* <0.001*
C3 <0.001* <0.001* <0.001*
C3 C1 <0.001* <0.001* <0.001*
C2 0.952 0.683 0.304

Note: Pairwise comparisons were performed using Tukey’s post hoc test. *p < 0.05 was considered statistically significant.

In the group evaluated with Beverage A, significant differences were identified between brands in most of the comparisons performed. However, at later time points, particularly between T4 and T6, some comparisons between C2 and C3 did not reach statistical significance, suggesting a tendency towards similar behavior between these two brands as strength degradation progresses. Despite this, brand C1 maintained significant differences compared to C2 and C3 at most of the evaluated time points.

In the group evaluated with Beverage B a pattern comparable to that observed with Beverage A was identified: most comparisons between brands were statistically significant, although at several later time points, the differences between C2 and C3 did not reach significance (p>0.05). This indicates that with exposure to this beverage, the brands’ mechanical behaviors tend to converge as the strength progressively decreases. Again, C1 showed significant differences from the other two brands at most time points.

Overall, the results show that the chain brands exhibited distinct mechanical behaviors from the beginning and throughout the evaluation period, with C1 showing the most differentiated pattern, while C2 and C3 tended to become more similar at late time points, especially under exposure to energy drinks.

Discussion

The oral environment is a dynamic setting in which multiple physicochemical and biomechanical variables capable of altering the mechanical behavior of orthodontic biomaterials converge. In this context, the decrease in force in orthodontic appliances occurs progressively under constant tension, and the limited capacity of these materials to maintain a stable force during their clinical period of use is also evident. This instability is clinically relevant, as it can translate into uncontrolled variations in the magnitude of tooth movement, which depend on both the brand and the exposure time, potentially compromising the efficacy and provisional nature of orthodontic treatment.24,25

The results obtained are primarily related to three factors affecting the degradation of dental appliances: the brand of the appliance, the evaluation time, and the oral environment, which was simulated through exposure to immersion solutions. These findings are consistent with those in existing studies, which documented significant differences in the mechanical behavior of dental appliances both between products from the same manufacturer and between different manufacturers.9,20,25–27

There are various configurations of ECs, depending on the technology used in their manufacture. These include conventional and memory ECs. Regarding the brand, the results show that C1 exhibited the greatest strength stability over time, while C2 and C3 showed similar degradation patterns. These findings are consistent with those reported by Aldrees et al,28 who indicate that strength degradation is not uniform among ECs of different brands, suggesting a direct influence of the manufacturer on their mechanical behavior. These findings are consistent with those reported by Masoud et al29 and by Kochenborger et al6 in their 21-day study, who observed significant differences in force degradation between the evaluated elastomeric chains. Taken together, these results support the clinical recommendation of Dehghani et al9 to consider material strength stability when selecting ECs, especially in patients with dietary habits that may accelerate elastomer degradation.

Regarding the chemical environment, several authors have proposed that the decrease in strength in elastomeric materials has an inverse relationship with the pH of the oral medium; however, this association should not be interpreted as a linear or isolated phenomenon.30,31 In the pilot test of this study, pH values of 2.63 and 2.98 were recorded in Beverage A and Beverage B, respectively, which could explain, at least in part, the greater loss of strength observed in the chains exposed to these beverages. These findings are consistent with those reported by Khaleghi32 who demonstrated a critical degradation of strength in ECs subjected to acidic environments. In addition to pH, other factors such as the concentration of preservatives, pigments, chlorides, and phosphates, along with temperature, could significantly contribute to strength degradation. Dehghani et al9 showed that soft drinks produced a notable loss of strength in the evaluated chains, reaching the highest degradation values at 28 days, attributed to its combination of acidity, phosphoric acid, and sugars.

Additionally, Pithon et al21 noted that the consumption of carbonated beverages can reduce the rate of tooth movement, associating this effect with the influence of sugars on bone metabolism.

When comparing the different immersion solutions, Beverage A induced the greatest loss of strength across all the chain brands evaluated, surpassing both Beverage B and the control group with artificial saliva. This pattern coincides with that reported by Abbass et al16 who observed significant differences in force degradation depending on the type of beverage at the end of four weeks. In particular, they found that carbonated, sugar-sweetened beverages caused greater degradation than others. This aligns with the reported findings, where Beverage A was more detrimental than Beverage B.

Furthermore, the degree of strength loss was greater in their study, which can be attributed to the number of daily immersions of the chains in energy drinks. Therefore, the importance of consumption frequency can be inferred: the more frequently acidic drinks are ingested, the greater the cumulative degradation of elastic strength.

Although Beverage A did show significant differences compared to the control group in this study, these findings do not coincide with those reported by Leão et al10 who, evaluated the behavior of intermaxillary elastics and concluded that the chemical nature of different beverages did not influence the percentage of strength degradation over time. This discrepancy between the two studies could be attributed to the difference in the type of material evaluated (continuous stretch chains versus intermaxillary elastics), as well as to variations in the composition, polymer structure, and mechanical behavior of each type of elastomer. This suggests that although intermaxillary elastics may be less sensitive to the chemical components of beverages, continuous stretch chains do exhibit greater susceptibility, especially to beverages with more aggressive characteristics, such as energy drinks.

The results show that the evaluated ECs were unable to maintain constant force release throughout the observation period. The greatest strength degradation occurred on the first day, followed by a considerably lower rate of degradation over the next four weeks. This is consistent with the findings of Torres et al33 who concluded that although the initial force exerted by the chains on the teeth is sufficient, changes occurring after 21 days can render it insufficient. These results contrast with those of Kumar et al,30 whose data were not statistically significant over the 28-day study period. Therefore, the orthodontist should educate the patient on scheduling regular appointments for optimal results and recommend avoiding energy drinks while wearing braces.

Melo et al21 noted that artificial saliva can induce greater strength degradation in elastomeric prostheses than that caused by various beverages, a statement that does not agree with the findings of the present study. This observation partially coincides with the results obtained, as it confirms that the simulated oral environment is a determining factor in strength loss. In addition, the systematic review by Andhare et al34 indicated that the strength loss recorded in in vivo studies is greater than that observed in in vitro models, suggesting that saliva components and the dynamic conditions of the oral environment significantly influence the progressive decrease in the elasticity of elastomeric materials.

Although this study’s in vitro design allowed precise control of the experimental variables, the findings do not fully reproduce clinical conditions, which limits their direct extrapolation to daily orthodontic practice. The behavior of ECs in the oral environment may be influenced by several factors not replicated in the experimental design, including salivary flow and buffering capacity, temperature fluctuations, oral microbiota, enzymatic activity, masticatory forces, intermittent stretching, oral hygiene habits, individual dietary patterns, and variations in the frequency and duration of contact between the elastomeric chains and the ingested beverages. Therefore, the magnitude of force degradation observed under laboratory conditions may differ from that occurring in vivo, where exposure to energy drinks is usually intermittent and modulated by the cleansing and neutralizing effects of saliva.

Consequently, future research should focus on conducting in vivo or in situ studies in patients who regularly consume energy drinks to confirm the clinical relevance of the observed findings. Furthermore, the implementation of automated measurement systems and the use of more precise equipment are recommended to optimize the reproducibility of the results. Similarly, it would be pertinent to evaluate other types of elastomers, such as ECs of different pigmentations or intermaxillary elastics, as well as to compare sugar-sweetened and sugar-free energy drinks, with the aim of isolating the specific effect of their various components. These lines of research will expand existing knowledge and strengthen evidence-based clinical decision-making.

Conclusion

Elastomeric chains exposed to energy drinks suffered significantly greater strength degradation than those kept in a neutral environment, confirming that consumption of these beverages can compromise the orthodontic force applied. The results also demonstrated brand- and beverage-specific differences, suggesting that material composition, manufacturing characteristics, and the chemical properties of the immersion solution may influence the resistance of elastomeric chains to force decay.

From a clinical perspective, these findings support the recommendation to limit the consumption of highly acidic energy drinks during orthodontic treatment, particularly when elastomeric chains are used for space closure or tooth movement control. However, because this study was conducted under controlled in vitro conditions, the results should be interpreted with caution and should not be directly extrapolated to all clinical scenarios. In the oral environment, factors such as salivary flow, buffering capacity, oral hygiene, dietary habits, masticatory forces, and the frequency and duration of beverage exposure may modify the degree of force degradation.

Therefore, while the present findings provide useful evidence for clinical decision-making and patient counseling, further in vivo and in situ studies are needed to confirm the real impact of energy drink consumption on elastomeric chain performance during orthodontic treatment.

Acknowledgments

The authors thank the Universidad Católica de Cuenca, Cuenca, Ecuador, for its constant and timely support. Eddison-Mauricio Pacheco-Quito, Katherine Cuenca-León, and Miriam Lima-Illescas are members of the Research Group: Innovación y Desarrollo Farmacéutico en Odontología, Jefatura de Investigación y Desarrollo, Universidad Católica de Cuenca, Cuenca, Ecuador. Edisson-Mauricio Pacheco-Quito is an associate member of the Academy of Sciences of Ecuador.

Funding Statement

The work was funded by the Universidad Católica de Cuenca, Cuenca, Ecuador, and is anchored to the research project called: “Evaluación mecánica y antimicrobiana del quitosano agregado en adhesivos ortodóncicos. Estudio in vitro”, approved under code PIC5P23-55.

Disclosure

The authors declare no conflicts of interest regarding the publication of this article.

References

  • 1.Kardach H, Biedziak B, Olszewska A, Golusińska-Kardach E, Sokalski J. The mechanical strength of orthodontic elastomeric memory chains and plastic chains: an in vitro study. Adv Clin Exp Med. 2017;26(3):373–12. doi: 10.17219/acem/61957 [DOI] [PubMed] [Google Scholar]
  • 2.Halimi A, Azeroual MF, Doukkali A, El Mabrouk K, Zaoui F. Elastomeric chain force decay in artificial saliva: an in vitro study. Int Orthod. 2013;11(1):60–70. doi: 10.1016/j.ortho.2012.12.007 [DOI] [PubMed] [Google Scholar]
  • 3.Younus AA, Kayarkar VS, Wankhade SB, Verulkar AA, Padmanaban A, Bhurani SR. Force decay of orthodontic elastomeric chains: a systematic review. IP Indian J Orthod Dentofacial Res. 2023;9(1):26–29. doi: 10.18231/j.ijodr.2023.006 [DOI] [Google Scholar]
  • 4.Braga E, Souza G, Barretto P, Ferraz C, Pithon M. Experimental evaluation of strength degradation of orthodontic chain elastics immersed in hot beverages. J Indian Orthod Soc. 2019;53(4):244–248. doi: 10.1177/0301574219867540 [DOI] [Google Scholar]
  • 5.Menon V, Madhavan S, Chacko T, Gopalakrishnan S, Jacob J, Parayancode A. Comparative assessment of force decay of the elastomeric chain with the use of various mouth rinses in simulated oral environment: an in vitro study. J Pharm Bioallied Sci. 2019;11:269–273. doi: 10.4103/JPBS.JPBS_9_19 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kochenborger C, Lopes D, Menezes E, Antunes D, Hahn L. Assessment of force decay in orthodontic elastomeric chains: an in vitro study. Dental Press J Orthod. 2011;16(6):93–99. doi: 10.1590/S2176-94512011000600015 [DOI] [Google Scholar]
  • 7.Javidi P, Bashardoust N, Shekarbaghani A. Evaluation of force decay rate in orthodontic elastomeric chains in the environment of various mouthwashes: a systematic review. Dent Res J. 2023;20:1–11. doi: 10.4103/1735-3327.372656 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Nakhaei S, Agahi RH, Aminian A, Rezaeizadeh M. Discoloration and force degradation of orthodontic elastomeric ligatures. Dental Press J Orthod. 2017;22(2):45–54. doi: 10.1590/2177-6709.22.2.045-054.oar [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Dehghani M, Alavian N, Noori N, Omidkhoda M. The Effect of different soft drinks on the force degradation of conventional and memory orthodontic elastic chains: an in-vitro study. Front Dent. 2023;20:1–9. doi: 10.18502/fid.v20i29.13347 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Leao Filho JCB, Gallo DB, Santana RM, Guariza-Filho O, Camargo ES, Tanaka OM. Influence of different beverages on the force degradation of intermaxillary elastics: an in vitro study. J Appl Oral Sci. 2013;21(2):145–149. doi: 10.1590/1678-7757201302256 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Aghili HA, Hoseini SM, Yassaei S, Fatahi Meybodi SA, Zaeim MHT, Moghadam MG. Effects of carbonated soft drink consumption on orthodontic tooth movements in rats. J Dent. 2014;11(2):123–130. [PMC free article] [PubMed] [Google Scholar]
  • 12.Pulgaonkar R, Chitra P. Stereomicroscopic analysis of microleakage, evaluation of shear bond strengths and adhesive remnants beneath orthodontic brackets under cyclic exposure to commonly consumed commercial “soft” drinks. Indian J Dent Res. 2021;32(1):98–103. doi: 10.4103/ijdr.IJDR_936_18 [DOI] [PubMed] [Google Scholar]
  • 13.Salih Al Qassar SS, Ismael AJ, Dewachi ZB. Influence of different types of mouthwashes on force decay of elastomeric chain recommended in SARS-COV-2 pandemic. J Orthod Sci. 2024;13(1):1–7. doi: 10.4103/jos.jos_18_24 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Al Qassar SSS, Qibi LH, Qasim AA, Dawood HM. Evaluation of antiseptic mouthwashes protocol against SARS-CoV-2 on orthodontic appliances (an in vitro study). Braz Dent Sci. 2024;27(2):1–8. doi: 10.4322/bds.2024.e4196 [DOI] [Google Scholar]
  • 15.Ajibo C, Van Griethuysen A, Visram S, Lake AA. Consumption of energy drinks by children and young people: a systematic review examining evidence of physical effects and consumer attitudes. Public Health. 2024;227:274–281. doi: 10.1016/j.puhe.2023.08.024 [DOI] [PubMed] [Google Scholar]
  • 16.Abbass NN, Albo Hassan AF, Nahidh M. The effect of energy drinks on force degradation of elastomeric chains (An in vitro study). J Orthod Sci. 2024;13(1):1–7. doi: 10.4103/jos.jos_43_24 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Von Bremen J, Kloukos D, Bettenhäuser-Hartung L, Schmid JQ. Energy drink-induced white spot lesions on labial and lingual tooth surfaces in adolescents treated with lingual appliances: a retrospective cohort study. Clin Oral Invest. 2025;29(7):370. doi: 10.1007/s00784-025-06445-8 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Subroto MIA, Putri APH, Putri LSDA, Hidayati L. Generation I and generation II elastomeric chains characteristics comparison in artificial saliva immersion. Brazilian Dent Sci. 2020;24(1):1–9. doi: 10.14295/bds.2021.v24i1.2180 [DOI] [Google Scholar]
  • 19.Mirhashemi AH, Saffarshahroudi A, Sodagar A, Atai M. Force-degradation pattern of six different orthodontic elastomeric chains. J Dent. 2012;9(4):204–215. [PMC free article] [PubMed] [Google Scholar]
  • 20.Martinez S, Torres E, Duran J, et al. Degradación de la fuerza de cadenas elastoméricas utilizadas en ortodoncia: evaluación in vitro. Cienc Frontera. 2021;175–180. [Google Scholar]
  • 21.Melo Pithon M, Lacerda-santos R, Rocha Santana L, Rocha M, Oliveira Leal R, Moura Santos M. Does acidic drinks vs Controls differents interfere with the force of orthodontic chain elastics? Biosci J. 2014;30(6):1952–1958. [Google Scholar]
  • 22.Pithon MM, Rodrigues AC, Sousa ÉLSM, De Souza Santos LP, Dos Santos Soares N. Do mouthwashes with and without bleaching agents degrade the force of elastomeric chains? Angle Orthod. 2013;83(4):712–717. doi: 10.2319/081012-646.1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Heidari S, Fattahi H, Oshagh M, Torkan S, Khajeh F. The effect of different environmental factors on force degradation of three common systems of orthodontic space closure. Dent Res J. 2015;12(1):50–56. doi: 10.4103/1735-3327.150331 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Torres-Reyes P, Manuel-Chávez GA, Cavazos-López E, Aguilera-Longoria I, Arellano-Sandoval Z. Evaluación de la degradación de la fuerza de cadenas elastoméricas de cuatro marcas diferentes [Evaluation of the degradation of the strength of elastomeric chains of four different brands]. Journal Odontol. 2019;23(12):42–50. [Google Scholar]
  • 25.Solis A, Daniela M, Chica C, Paulina F, Calderón B, Estuardo M. Estudio in vitro de la durabilidad, deformación elástica y plástica de tres tipos de módulos elastoméricos [In vitro study of durability, elastic and plastic deformation of three types of elastomeric modules]. Rev Latinoam Ortodon Odontopediatr. 2014;1–14. [Google Scholar]
  • 26.Mousavi SM, Mahboobi S, Rakhshan V. Effects of different stretching extents, morphologies, and brands on initial force and force decay of orthodontic elastomeric chains: an in vitro study. Dent Res J. 2020;17(5):326–337. doi: 10.4103/1735-3327.294331 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.da Andréa Fonseca JM, Adriana de Alcantara CS, Lincoln IN. Avaliação in vitro da força liberada por elásticos em cadeia [In vitro evaluation of force delivered by elastic chains]. Dental Press J Orthod. 2011;16(6):1–8. [Google Scholar]
  • 28.Aldrees AM, Al-Foraidi SA, Murayshed MS, Almoammar KA. Color stability and force decay of clear orthodontic elastomeric chains: an in vitro study. Int Orthod. 2015;13(3):287–301. doi: 10.1016/j.ortho.2015.06.003 [DOI] [PubMed] [Google Scholar]
  • 29.Masoud AI, Tsay TP, BeGole E, Bedran-Russo AK. Force decay evaluation of thermoplastic and thermoset elastomeric chains: a mechanical design comparison. Angle Orthod. 2014;84(6):1026–1033. doi: 10.2319/010814-28.1 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Kumar K, Shetty S, Krithika MJ, Cyriac B. Effect of commonly used beverage, soft drink, and mouthwash on force delivered by elastomeric chain: a comparative in vitro study. J Int Oral Health. 2014;6(3):7–10. [PMC free article] [PubMed] [Google Scholar]
  • 31.Nobahari M, Safari F, Geramy A, Hooshmand T, Kharazifard MJ, Arab S. Effect of three common hot beverages on the force decay of orthodontic elastomeric chain within a 28-day period: an in vitro study. Korean J Orthod. 2024;54(3):153–159. doi: 10.4041/kjod23.160 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Khaleghi A, Ahmadvand A, Sadeghian S. Effect of citric acid on force decay of orthodontic elastomeric chains. Dent Res J. 2021;18(31):1–7. doi: 10.4103/1735-3327.316648 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Torres-Rosas R, Torres-Gómez N, Camero-Leal JA, Jurado C, López-Ravelo H, Argueta-Figueroa L. Force decay and elongation of orthodontic elastomeric chains exposed to different beverages common in the diet: an in vitro study. Dent Med Probl. 2023;60(3):413–420. doi: 10.17219/dmp/148052 [DOI] [PubMed] [Google Scholar]
  • 34.Andhare P, Datana S, Agarwal SS, Chopra SS. Comparison of in vivo and in vitro force decay of elastomeric chains/modules: a systematic review and meta analysis. J World Fed Orthod. 2021;10(4):155–162. doi: 10.1016/j.ejwf.2021.07.003 [DOI] [PubMed] [Google Scholar]

Articles from Clinical, Cosmetic and Investigational Dentistry are provided here courtesy of Dove Press