Abstract
Operating matter-wave interferometers as quantum detectors for fundamental physics or inertial sensors with unprecedented accuracies relies on noise rejection, often implemented by correlating multiple sensors. They can be spatially separated (gradiometry or gravitational-wave detection) or consist of different internal states (magnetometry or quantum clock interferometry), with a signal-amplitude modulation serving as a signature of a differential phase. In this work, we introduce parameter estimation from amplitude collapse (PEAC) by applying statistical inference techniques for different magnetically sensitive substates of an atom interferometer. We demonstrate that PEAC provides higher trueness, resulting in a substantially reduced bias compared to standard methods for perfectly correlated signals, while achieving competitive precision near, but not at, vanishing amplitudes. This indicates that vanishing signals do not constitute the most favorable working point for high-accuracy sensing, relevant to quantum clock interferometry. PEAC presents a generally applicable complementary evaluation method for correlated interferometers without phase stability, increasing the overall accuracy and enabling applications beyond atom-based interferometry.
INTRODUCTION
To exploit the full potential of atom interferometers as quantum sensors at the highest accuracy, the signal of interest is often encoded in the differential phase between two correlated interferometers. This strategy suppresses common-mode noise and is an established, yet crucial tool for high-precision measurements, e.g., setting new records in the determination of the fine-structure constant (1, 2), forming the working principle of quantum-based gravitational-wave or dark-matter detectors (3–5) on large baselines (5, 6) and being central to operational and proposed quantum tests of fundamental physics (7–10) and general relativity (11–18). It is also key for robust sensors (19, 20) used in magnetometry (21–24), gyroscopy (25–28), or gradiometry (29–31) with applications in inertial sensing, exploration, and navigation (27, 32). In such real-world applications, the differential phase can be extracted even in noisy environments, where the interference signal cannot be resolved in a single interferometer.
However, differential phase estimation in correlation measurements poses its own challenges even for established techniques such as fitting ellipses to parametric plots of noisy but correlated bivariate data that extract the phase from the ellipses’ eccentricity (33–36).
Because concepts for specifying measurement quality are not used consistently across subfields, we adopt the following definitions (37, 38): Trueness denotes the closeness of the estimated (reconstructed) phase to the true (e.g., set) phase . As a practical quantitative measure of trueness, we consider the bias . Precision characterizes the closeness of agreement of repeated estimates under identical conditions. We therefore choose the spread, i.e., the standard deviation associated with the estimation process, as a quantifiable measure. Accuracy refers qualitatively to the combined effect of trueness and precision. While typically precise, ellipse-based phase estimation becomes biased except for a circle ( and odd multiples). These are the only phases where the estimator is unbiased. For all other cases, a systematic error is introduced. The trueness of the phase estimate degrades strongly near degeneracy points (), where the underlying ellipse collapses to a line.
In this work, we propose and implement parameter estimation from amplitude collapse (PEAC) as an additional, complementary statistical technique for noisy matter-wave interferometers and implement it for correlated interferometers in magnetometry and for velocimetry by deliberately inducing an amplitude collapse. We demonstrate, both experimentally and theoretically, that PEAC enhances the trueness by a bias reduction for a broad range of phase settings in magnetometry, albeit at the cost of precision, yielding overall improved accuracy also near the degeneracy points, i.e., for perfectly in-phase or -phase–shifted correlated interferometers.
PEAC is inspired by quantum clock interferometry (39–44), where a superposition of internal states undergoes an atom-interferometer sequence, creating a spatial superposition in which possible relativistic (45, 46) and proper-time effects (47) encode a periodic signal-amplitude loss associated with which-path information (48). Here, the internal states acquire different interferometer phases, e.g., due to relativistic effects associated with mass-energy equivalence, but are not measured individually. In particular, atoms in different internal states have slightly different rest masses due to their internal energy, known as mass defect (49, 50), which leads to state-dependent phase evolution in the interferometer. Although these differential phase shifts are typically minute and can, in certain situations, also be extracted using the methods discussed below, the question remains how such a signature can be most effectively used in quantum clock interferometry. Recent experiments (51) operate beyond the perturbative regime, with differential phases induced by magnetic field gradients, a mechanism that we also use in the present work.
Similar to those quantum-clock schemes, PEAC does not necessarily require measuring correlated interferometers individually but relies on the detection of (possibly incoherent) mixtures of them. A differential phase shift between the individual interferometers induces a beating of their superposed interference fringes. This characteristic structure manifests as collapses and revivals of the combined signal’s oscillation amplitude, whose pattern appears in statistical histograms of population measurements, extractable (32, 52–54) even when suffering large phase noise.
We analyze the PEAC performance in atom interferometers containing a stochastic mixture of magnetically sensitive substates to estimate the acceleration induced by a magnetic-field gradient. Using state-selective measurements, we compare this technique to corresponding ellipse fits, demonstrating that PEAC provides a complementary statistical analysis of existing correlation data not through joint phase fitting but via an optimally chosen transformation of the bivariate coordinates and their amplitude marginal distributions. Such an analysis can be always performed and optimized in addition to ellipse fits. PEAC demonstrates improved overall performance, with the highest accuracy for phases near, but not exactly at degeneracy points, in contrast to expectations from Gaussian uncertainty propagation. The signal amplitude is small but still finite, providing a working point that exhibits negligible bias and precision comparable to ellipse fitting. This observation highlights a distinct operating regime that differs from geometric phase amplification (51).
The method extracts a measurand, in our case the differential phase of interest, from histograms of a suitably chosen linear combination of correlated signals. It therefore requires a model for the dominant noise and for the functional dependence of the probability distribution on the measurand, in our case through the amplitude of an interference pattern. The method also depends on the weights or mixture fractions that define the combined signal. These weights, or other distribution-specific parameters, may be determined either by scanning the measurand or, if this is experimentally inaccessible, from independent experiments, as demonstrated below.
PEAC applies to a wide range of cases: coherent implementations such as quantum clocks and incoherent, stochastic mixtures of components. It allows extracting phase information in setups previously considered unsuitable, e.g., when these components spatially overlap. At the same time, it can also be applied in situations where components can be individually resolved, a necessary condition for ellipse fitting. Moreover, PEAC enables phase extraction even when phase fluctuations prevent fringe resolution in correlated interferometer signals (55, 56) and when the differential phase cannot be tuned, providing a valuable toolbox for next-generation platforms (13, 20, 21, 52, 54, 57) for matter-wave sensors with ultracold quantum gases. Furthermore, we extend the approach to related estimation problems in which information is encoded in contrast or envelope parameters, such as the extraction of effective temperatures or rotation rates from contrast-envelope fitting in atom interferometry (58–60). Last, it can be combined with any statistical inference technique, such as least-squares fitting or maximum likelihood estimation.
RESULTS
PEAC methodology
PEAC is an estimation method applicable to interferometric experiments that extracts the value of a parameter of interest from the amplitude of an interference signal without the need to resolve an individual interference fringe. We demonstrate this for two distinct parameters: the differential phase between correlated interferometers, extracted from the characteristic amplitude collapse of a combined signal for magnetometry in the “Magnetometry” section, and the momentum width of an atomic cloud, extracted from the decreasing amplitude upon deliberately opening the interferometer to reduce the clouds’ overlap in the “Velocimetry” section.
The parameter of interest is extracted from a statistical model with a known probability density function (PDF), which is experimentally probed by repeated measurements used to construct histograms. The PDF can be fitted directly to these histograms or one can use more sophisticated procedures such as maximum likelihood estimation to extract the PDF’s parameters (see the Supplementary Materials).
The PDF generally depends not only on the parameter of interest but also on additional experimental quantities, such as the intrinsic contrast. If a control parameter is experimentally accessible that induces a characteristic variation of the amplitude, then PEAC can be operated in scanning mode, permitting the simultaneous extraction of both intrinsic parameters and the quantity of interest. We demonstrate this mode of operation by scanning the differential phase for magnetometry and the timing asymmetry for velocimetry, from which the respective quantities of interest are extracted via a fit to the amplitude model.
If no such control parameter is accessible, but the intrinsic parameters of the PDF are sufficiently characterized by independent measurements, then PEAC is operated in static mode, allowing the quantity of interest to be estimated from a single experimental configuration. We demonstrate static operation in the “Correlation measurements—Connection to ellipse fitting” section, where we independently determine the intrinsic contrast from the individual signals of two correlated interferometers, which is then used to infer the magnetic field gradient without the necessity to scan the differential phase.
Magnetometry
In this subsection, we illustrate PEAC in scanning mode for a concrete experimental implementation exploiting the connection between the beat amplitude and a differential phase in a three-level system, as well as the associated level populations. Specifically, we apply PEAC to atom interferometry-based magnetometry (21–24) in one dimension, a benchmark application well-suited to typical vibration-prone environments and compact devices, even when state-selective interferometry is unavailable. Ultracold 87Rb atoms from a Bose–Einstein condensate (BEC) provide a suitable point source (32) with subrecoil momentum width, coherence, and access to efficient Bragg diffraction (61). Our experiment (62) creates BECs in a far-detuned crossed optical dipole trap (CDT), typically with 20,000 atoms at and a condensate fraction exceeding 80%. When no optical pumping or magnetic quantization is applied, the atoms occupy a stochastic mixture of all magnetic substates of the ground-state manifold . All states are addressed and Bragg-diffracted by a pair of counter-propagating laser beams (63) with a frequency difference , coupling the two momentum states and with the modulus of the effective wave vector of the two-photon Bragg transition. With these Bragg pulses, we implement a Mach–Zehnder atom interferometer (MZI) in a pulse configuration as illustrated in Fig. 1A. The laser-intensity envelopes of all three pulses are shaped as Blackman window pulses (64, 65) of length . We label the temporal separation of the maxima of two consecutive pulses by and , respectively. Identical values and result in a total duration of the MZI sequence up to .
Fig. 1. Spacetime diagram and signal extraction.

(A) Mach–Zehnder atom interferometer (MZI) realized by three Bragg pulses separated by and , respectively, driving transitions between momentum states (purple) and (green). The phase of the final pulse is shifted by , thus scanning the interference fringes at the two exit ports. The MZI is followed by a TOF that spatially separates the exits, during which an optional Stern–Gerlach (SG) field can separate the substates of the ground state within each momentum class in addition. (B) Fringe scans (20 settings of , 15 repetitions averaged, uncertainties omitted for visual clarity) at . Without the SG field, we observe the fringe (black), with the corresponding histogram from 300 measurements (left marginal, also displayed as a density plot on the far left) has a double-peak structure that depends on the signal’s amplitude. Applying an SG field allows resolving the individual signals per substate (blue, indigo, and red), whose histogram distributions are shown at the right marginal. The individual signals show equal amplitudes, while the amplitude of is reduced due to summation of the individual with shifted phases. (C) Combined density plot of the histograms of , obtained for a scan of the interferometer time , reveals the collapse and revival of the amplitude caused by the incoherent overlay of the three signals . The white lines trace the calculated amplitude as , parametrized by Eq. 3. The black dashed line corresponds to the data shown in (B).
After the symmetric MZI, a time of flight (TOF) spatially separates the interferometer output ports associated with the momentum states for measuring the atom numbers in different momentum classes , with the interferometric phase , baseline , and amplitude . We define the interferometer signal as the normalized population difference, i.e.,
| (1) |
where the signal’s baseline and amplitude satisfy and depend on . For more details on the experimental apparatus and the derivation of , we refer to Materials and Methods.
By characterizing , for example, by scanning an interferometer fringe, one can extract the interferometric phase and thus the quantity of interest influencing . For instance, this could be the projection of an external acceleration in the direction of the Bragg beams. To scan an interference fringe, we offset the phase of the final pulse by 20 evenly spaced values of . We perform 15 repetitions per for improved signal to noise. A typical fringe for is shown in the center panel of Fig. 1B by the black trace. We see a clear oscillation and periodicity of the fringe characterized by its amplitude , phase , and baseline . If remains stable between all pulses, then a cosine can be fitted to the fringe, providing direct access to these parameters. Conversely, in the absence of phase stability, the amplitude and baseline of can be obtained via a statistical analysis (52, 54, 66, 67), albeit at the cost of losing the phase information. This procedure also can be applied to data obtained under phase-stable conditions, such as our measurements at small .
To demonstrate this statistical method, we show, at the left margin of Fig. 1B, a histogram associated with the fringe in black, where the statistics is generated from all 300 contributing measurements. The very left column shows the same histogram converted into a density plot using false-color coding. We observe the typical double-peak structure of the histogram (52, 66), where the distance of the peaks is roughly given by and their individual width is determined by baseline fluctuations of . This characterization is valid for a homoscedastic signal, where does not fluctuate, as specified in Materials and Methods, which is dominated by technical noise and operates well above the quantum-projection noise limit.
In addition to scanning via for a fixed value of , we also vary the interferometer time in steps of . The corresponding histograms are displayed as a composite density plot in Fig. 1C, where each column is obtained in the same way as in Fig. 1B corresponding to the histogram behind the dashed black line at . We observe a decrease of the signal amplitude for increasing with a collapse at , which is not due to loss of coherence, since revives for longer times. This behavior is caused by an underlying modulation of , which is a consequence of the beat of the three signals defined in analogy to Eq. 1 and associated with three substates. The substates experience a state-dependent acceleration, partly due to a magnetic field gradient, acquiring different phases , which induce this characteristic collapse and revival behavior. The magnetically insensitive substate acquires the phase , including and accelerations and perturbations common to all substates. The magnetically sensitive states with pick up the phases with the differential phase
| (2) |
between the two substates, induced by a Zeeman force that accelerates the state by in the direction of the Bragg beams and the state by the same magnitude but in the opposite direction. Here, we correct the conventional MZI phase for finite-pulse durations (68) in , which can approach 0.1 in our case with for short interferometer times. We present the derivation of the numerical factor in Materials and Methods.
In our experiment, we have additional access to the individual substates by applying the Stern–Gerlach (SG) method (69, 70) during a TOF after the MZI: In each momentum exit port, we can create a spatial separation of the substates by applying an additional magnetic field gradient as depicted in Fig. 1A (right). This method allows us to determine the oscillatory signal of the individual substates as displayed in the center panel of Fig. 1B, along with the corresponding histograms at the right marginals. As expected, we observe the same oscillation amplitude for all three substates, which is in particular larger than . Based on this insight, we conclude that in a nonstate-selective setting, the observable is , where are the weights of each substate in the incoherent stochastic mixture.
In the remainder of this section, we focus on this nonstate-selective setting. Here, the observable can be written as . The offset can be interpreted as a geometric phase (51) and depends on and (Materials and Methods). Here, is the baseline, and
| (3) |
is the amplitude, with the population imbalance , assuming . In this particular setting, we cannot access the differential phase directly from a histogram recorded for a single interferometer time , since the weights are unknown. However, scanning the interferometric time allows to infer . The underlying reason is the characteristic variation of the amplitude with , as evident from Eqs. 2 and 3, due to the overlay of the three individual interferometer signals with their respective phases. Crucially, the technique does not intrinsically require a scan of , provided the auxiliary parameters and are constrained by independent measurements or deterministic tuning, as is done in quantum clock experiments. In this case, the static mode of PEAC can be used to reconstruct the phase for each experimental setting.
In the present section, PEAC in its scanning mode is explicitly performed by fitting the histogram’s PDF for each to obtain , where the form of the PDF (52, 54, 67) and further details can be found in Materials and Methods. Using , we fit Eq. 3 with the help of Eq. 2 to extract the acceleration and further parameters , , , and . We calculate the modulated amplitude from these values and plot as white lines in Fig. 1C. The uncertainty of and all other experimental uncertainties in the following are obtained via bootstrapping (71–73), as explained in Materials and Methods.
Even in the presence of phase instability and a nonstate-selective setup, PEAC allows one to estimate the differential phase and thus . We emphasize that phase information cannot be extracted from a single histogram when the intrinsic PDF parameters are not independently known; however, by considering multiple times , the collapse of the amplitude enables the extraction of the phase. For comparison, as we have direct access to from SG population measurements, we directly obtain , , , , and , averaged over all values. These measured populations vary with every experimental realization and are unknown, if no state-selective detection is performed. While there are drifts on longer timescales, the population mixture appears constant within experimental uncertainties on the timescale of the performed experiments. Here, is the average amplitude of the substates obtained by fitting the individual histograms. These results are in good agreement with those obtained using PEAC.
If the populations and amplitude are known, e.g., from other, independent calibration measurements or the state preparation procedure, then the differential phase can be estimated from a single set of data for a fixed interferometer time , so that no control over the differential phase is necessary to implement PEAC. With these quantities at hand, Eq. 3 can be applied pointwise, so that we demonstrate PEAC in static mode in the “Correlation measurements—Connection to ellipse fitting” section. Last, we highlight that PEAC can even be applied to systems with more than three states, albeit at the cost of a richer beat structure of the amplitude (Materials and Methods).
Velocimetry
In the previous section, the observed amplitude collapse was caused by a beat signal of three correlated interferometer signals encoding a differential phase. We now demonstrate the broad applicability of PEAC by performing velocimetry of atomic clouds to determine their momentum width . Since we expect the same behavior for all substates, we restrict the analysis to the component extracted from a state-selective detection via the SG method. Similar to contrast envelope fitting (58–60), the interferometer is deliberately opened (74) according to Fig. 1A by shifting the last pulse by with a step size of . We operate the interferometer at a fixed value of and record five phase scans as described in the “Magnetometry” section, totalling to 100 realizations per . The timing asymmetry reduces the spatial overlap of the wave packets propagating along the two arms at the output ports. The resulting displacement scales as with the mass of 87Rb atoms. Assuming a Gaussian momentum distribution with width , the amplitude of the interference signal is suppressed by a Gaussian envelope with an apparent coherence time . Similar to magnetometry, we apply PEAC by extracting the amplitude from fits of the PDF to the histograms of the interferometer signal, again employing thousandfold bootstrapping. These amplitudes are then fitted to the Gaussian envelope to extract . In Fig. 2, we show the density plots of the resulting histograms with white solid lines tracing the envelope for the averaged fit parameters. We obtain and , with the center of the Gaussian shifted by . Given this apparent coherence time, we estimate the rms momentum spread as , which translates to an effective temperature of . These results agree with the widths obtained by TOF measurements (), with the remaining difference attributed to a broadening of the ensemble by resonant absorption imaging and contributions of the thermal component (75). Using the timing asymmetry as a control parameter, PEAC therefore enables the determination of the momentum width of an atomic ensemble from the collapse of the amplitude in a deliberately opened interferometer.
Fig. 2. Amplitude collapse in an open interferometer.

Density plot of an open interferometer signal for the component. Increasing timing asymmetry reduces the overlap of the two interferometer arms in the output, leading to an amplitude collapse. The white solid line traces the envelope of the amplitude collapse used to extract the momentum width of the atomic cloud.
Correlation measurements—Connection to ellipse fitting
As demonstrated in the “Magnetometry” section, PEAC can be used to extract differential phases from the overlay and resulting beat of correlated signals in the scanning mode. Here, we turn to the static mode establishing a connection to ellipse fitting. In addition to emphasizing the application to systems without state-selective measurement capabilities, we now shift our focus to correlated systems in a setup that allows for state selection, where all intrinsic parameters of the PDF have been obtained from independent measurements. In this case, no control over the quantity of interest, i.e., the differential phase , is required, and PEAC can be applied to each dataset at fixed interrogation time . Acknowledging that correlation measurements also can be carried out in systems with more than two distinct components (41, 76, 77), we restrict our evaluation to a two-state system, similar to typical quantum clocks using pulses to generate coherent superpositions between two internal states. We immediately can investigate this in our system by applying the SG method to distinguish the signals and choosing a symmetric sum of the states while excluding the magnetically insensitive state (). The summed signal
| (4) |
is scaled by choosing , anticipating Eq. 6. Evaluating Eq. 3 for this system and gives the amplitude modulation (45, 47)
| (5) |
In panels (a) to (d) of Fig. 3A, we plot the averaged fringes of the individual signals and for four distinct interferometer times , i.e., different phases . For increasing , phase noise induces a reduction in the observed fringe amplitudes of and , which are equal in magnitude. The observed fringe amplitude of decreases accordingly but is in addition modulated by and depends on the phase difference.
Fig. 3. Interference fringes, amplitude collapse, and signal correlation.

(A) Colored dots in panels (a) to (d) show the averaged interference fringes of (red), (blue), and (orange) for four different values of , i.e., for distinct differential phases . The beat of and leads to a collapsing amplitude of for (c). Uncertainties are omitted for visual clarity. (B) Collapse and revival of the amplitude (white) as a function of , inferred from the underlying histograms of shown as density plot, where darker regions correspond to higher bin counts. The collapses occur at the beat nodes around and . Dashed black lines indicate the times (a) to (d) from (A). (C) Bivariate scatter plots for times (a) to (d) of the correlated signals (vertical) and (horizontal), with a color coding as in (A) indicating the phase scan of . The eccentricity of the emerging ellipse encodes the differential phase . At and , the ellipses become degenerate and collapse to lines along the antidiagonal and diagonal, respectively.
The signals range from being slightly (a) and notably (b) out of phase via a vanishing in (c) for a differential phase to a rephasing at in (d). Resorting again to PEAC, we show the corresponding density plot of the histograms in Fig. 3B, with black dashed lines marking the chosen times from Fig. 3A. This visualization shows the collapse and revival of the amplitude with and by that with varying differential phase . The beat node of the signal at () becomes visible, with a secondary node discernible at (). Fitting the histogram PDF to for each interferometer time returns the time-dependent amplitude , while fits to can be used to obtain . The white line in Fig. 3B shows the envelope given by Eq. 5 for averaged values of and , obtained by bootstrapping the data and fitting. This envelope corresponds to the intrinsic amplitude of the signal, which is larger than the observed fringe amplitude, as the analysis of histograms is robust against phase noise.
Beside fitting the amplitude modulation, a known allows the pointwise estimation of the differential phase by inverting Eq. 5. To account for the ambiguity of the inverted cosine function, we unwrap the phase. Fitting Eq. 2 to the reconstructed phases returns an external acceleration of , which is in excellent agreement with our prior results.
We compare PEAC to a more established evaluation scheme for correlated systems based on parametric plots and fitting ellipses (33–35, 78–81). The correlated signals for the interferometer times of Fig. 3A are visualized in a bivariate scatter plot in Fig. 3C, with along the horizontal and along the vertical axis; each measurement realization is shown as a colored dot. The color is chosen to represent the adjusted phase , which results in a color gradient for the performed phase scan as can be seen in subfigures (a) to (d). For larger interferometer times , the color gradient becomes disordered, showing a transition to the phase-unstable regime of the experiment. While a scan of the phase traces the ellipse, the differential phase is encoded in its eccentricity, which we extract from geometric ellipse fitting routines (21, 82–84). A detailed explanation of our fitting routine can be found in Materials and Methods. With this approach, we estimate an external acceleration of , confirming the results obtained by PEAC.
In fact, both methods are inherently connected: The principal axes of the ellipses in Fig. 3C [(c) and (d)] are given by the diagonal and antidiagonal (see Materials and Methods for more details). The diagonal is proportional to the sum of the bivariate coordinates , while the antidiagonal is proportional to their difference . Rotating the bivariate coordinate system by the angle leads to the definition of the general signal
| (6) |
Hence, the special case denotes the axis along the diagonal and can be accessed even without state-selective measurements for two-component systems. A second case is , oriented along the antidiagonal, which can only be inferred in a state-selective setup. Consequently, for two correlated states such as presented here, applying PEAC generalizes to performing a statistical histogram analysis of the bivariate data along any angle . In Fig. 4, we depict the ellipses aligned to their principal axes and , i.e., rotated by clockwise, for (left) and (right) in the bivariate variables with complementing histograms at the marginals. The displayed ellipses are close to degeneracy, i.e., (left) and (right), where the method of ellipse fitting has known limitations. Especially large baseline fluctuations lead to large biases of the estimated phase close to these degeneracy points. Generally, the rotation angle encodes the population ratio of the two involved states and reflects any imbalance due to imperfect state preparation. In addition, for any recorded bivariate dataset, histograms can be constructed and analyzed along a chosen direction , complementing the ellipse-based analysis. For a detailed analysis of different choices of , we refer to the Supplementary Materials but report here the key insights. From simple Gaussian uncertainty propagation, one expects that is the optimal choice. However, this idea neglects a possible dependence of the amplitude uncertainty arising from the explicit fitting procedure. Taking this into account shows that PEAC can benefit from a slight deviation from in terms of a better trueness over a wider range. The optimal choice of can generally depend on the specific use case and application, such that we refrain to specify a single best value here and focus on for the remainder. In the following section, we investigate the systematic error and compare PEAC in trueness and precision to the ellipse fitting approach.
Fig. 4. Rotated bivariate scatter plots and histograms.

Rotating the original correlation signals (insets) for (, left) and (, right) by clockwise aligns the ellipses to their principal axes, which correspond to (horizontal) and (vertical). The marginal distributions show the histograms of and , illustrating that the two exchange their roles at the respective degeneracy points of . This representation visualizes the intrinsic link between ellipse-based estimation based on bivariate fitting and PEAC applied to and . Note that is only accessible by state-selective detection.
PEAC performance
To quantify the performance of PEAC, we assess the trueness and precision of phase estimation, without relying on scanning the differential phase. Figure 5A displays the unwrapped phase , reconstructed individually from the experimental data for each from geometric ellipse fitting (dark blue crosses, masked by orange crosses for most data points); see Materials and Methods for details. For a complementary theoretical analysis establishing a connection between experiment and theory, we use the control variable , which we convert to the corresponding via Eq. 2 using . Ideally, we expect the black dashed line representing identity, corresponding to perfect phase reconstruction , yet notable deviations of the experimental data occur. This discrepancy becomes more evident for the numerical replication of the experiment, shown as the dark blue line. We use the experimentally inferred parameters characterizing the signals (see details in Materials and Methods). In essence, the numerical replication allows for a much finer sampling of . The largest discrepancies occur at , i.e., at points of degeneracy, which are a fundamental limitation to ellipse-based phase estimation (33, 81). We experimentally study one of these degeneracy points in more detail: The inset at illustrates this discrepancy through a finer experimental sampling in . In this inset, the center of each rectangle denotes the mean, while its height is twice the empirical standard deviation extracted from bootstrapping, caused by the statistical nature of the baseline fluctuations. The experimental data obtained from ellipse fitting (dark blue) exhibits the same qualitative behavior as the numerical replication, thereby confirming the validity of our theoretical model. Hence, a bias in the vicinity of the degeneracy points deteriorates the trueness of the estimated phase.
Fig. 5. Performance of phase estimation: Ellipse fitting versus PEAC.

Comparison of ellipse fitting (dark blue) and PEAC along the (orange) and (light blue) directions. Experimental data are shown as crosses (error bars omitted for clarity) or rectangular bars, with centers indicating the mean and heights equal to twice the bootstrapped standard deviation. Solid lines are values obtained from numerical replications of the experiment. The dashed lines correspond to the set phases and amplitudes as reference values free of fitting errors. We convert the set phase via Eq. 2 to . (A) Reconstructed phase. The inset shows that ellipse fitting leads to a large bias near degeneracy despite high precision, while PEAC along the minor axis exhibits larger uncertainty but a reduced bias. (B) Modulation of the amplitudes and obtained from histogram fits along the two principal axes. We observe a deviation at degeneracy, contributing to PEAC’s remaining bias. (C) Bias obtained from numerical replications. PEAC along the favorable (minor) axis increases the effective bias-free region by a factor of 1.6 compared to ellipse fits, substantially enhancing trueness. The semi-transparent bands give the uncertainties extracted from 1000 replicated experiments. (D) Precision of phase estimation. Ellipse fitting maintains low uncertainty across all , while PEAC of achieves comparable precision only near, but not at the degeneracy point , as would be expected from simple Gaussian uncertainty propagation. This behavior arises from an ambiguity in the histogram’s PDF for small amplitudes. For PEAC, a distinct minimal uncertainty can be found, marking an optimal working point (see green arrow). The visible reduction in the ellipse’s uncertainty around the degeneracy points stems from the least-squares fitting routine converging to the boundary condition for the major semi-axis.
Figure 5B presents the amplitudes (orange) and (blue) of and , extracted from histogram fits. The data underline the collapse and revival behavior. Fits to the numerical replication lead to the solid lines for (orange) and (blue), which are phase shifted by , as expected from Fig. 4. The insets magnify the deviation near the degeneracy points. As in Fig. 5A, we present the ideal amplitudes and by black dashed lines. Applying PEAC to the experimental data, we infer via Eq. 5 and thus obtain the orange crosses in Fig. 5A and rectangles in its inset. See Materials and Methods for a detailed description of the full protocol. Compared to the reconstruction via the ellipse method, we see a larger standard deviation and by that a decrease in precision.
The numerical replication allows us to quantify the respective bias of the different estimation methods, shown in Fig. 5C as solid lines (dark blue: ellipse, orange: , blue: ). Enabled by state-selective detection through the SG method and postprocessing of the data, the difference signal is also analyzed using PEAC, revealing that the bias is -phase shifted relative to . The traces directly show the averaged bias and are a measure of trueness (high if ), while the shaded areas represent the uncertainty in phase reconstruction, obtained from statistical repetitions as detailed in Materials and Methods, and quantify the precision: Smaller uncertainty bands correspond to higher precision. This plot illustrates the challenges of the ellipse fitting method: While it can achieve high precision, it suffers from major bias leading to low trueness, particularly at points of degeneracy. For our data, the ellipse fitting method has negligible bias except for an interval of around the degeneracy points. In contrast, PEAC substantially increases the bias-free region, so that a bias is only observed in an interval around degeneracy and therefore enhances the trueness at the expense of precision. We also observe that and reverse their roles at opposing degeneracy points, such that applying PEAC to around benefits from higher precision, while analyzing is favorable around . Considering the bivariate plane of Fig. 4, we understand this behavior geometrically: The bias and precision are only substantially reduced when the histogram is obtained by projecting along the minor axis of the ellipse. We give more insights into the bias’s origin in Materials and Methods. Along the favorable minor axis, PEAC extends the range of phases for which effectively bias-free estimation is possible by a factor of 1.6 compared to ellipse fitting. Even along the major axis, PEAC performs slightly better than ellipse fitting, although with a high uncertainty, which depends on the number of measuring points and further optimization schemes (54). For phases within around degeneracy, we observe considerable variations in bias across all three cases. Since the variation amplitude is the smallest for the favorable direction of PEAC, it maintains a reduced bias and remains the optimal choice for phase estimation in this regime. Thus, PEAC achieves higher trueness compared to the ellipse method, which is a necessary condition for high-accuracy measurements, for which both trueness and precision are essential.
Last, we compare the precision of both methods by investigating the phase uncertainty shown as shaded areas in Fig. 5C. The values of the uncertainty are displayed as solid lines in Fig. 5D for a direct comparison. To benchmark the theoretical analysis, we also add the corresponding experimental values as crosses and vertical bars in the inset around degeneracy (dark blue: ellipse fitting, orange: , blue: ). The uncertainty of the ellipse method is almost constant across all phases and consistently lower than that of PEAC, for both and . The dip of its uncertainty around degeneracy arises because the geometric ellipse fits are constrained by boundaries that enforce physically reasonable, i.e., normalized, principal axes. Apparently, the tendency to converge to these boundaries reduces the statistical uncertainty. Nevertheless, PEAC can achieve uncertainty levels as low as ellipse fitting for specific phases near, but not exactly at degeneracy. In quantum clock interferometry, simple Gaussian uncertainty propagation suggests , where is the uncertainty of the oscillation amplitude. Following this intuition, the amplitude exhibits its steepest slope and by that the lowest uncertainty at . In contrast, a vanishing slope at implies a diverging phase uncertainty and explains why the major axis is unfavorable for PEAC along . However, as shown in the inset of Fig. 5B, we observe that near the degeneracy point , the fitted value of deviates from the expected behavior. This deviation and the connected increase in uncertainty arise from a merging of the two maxima of the PDF for low amplitudes, resulting in a single-peak PDF. Although no closed analytical expression describes this transition, a numerical analysis reveals that it occurs when , where is the standard deviation of the baseline fluctuations. Since depends on , this transition from a double-peaked to a single-peaked PDF can be associated with a differential phase, which for our experimental parameters is . This differential phase aligns well with our observation of an increase in both bias and uncertainty. To show that this observation holds for various settings, we performed a scan of the baseline noise . The corresponding two-dimensional scans are summarized and compared against ellipses in the Supplementary Materials. We observe that both bias and uncertainty of the phase estimation based on PEAC depend on baseline fluctuations. While ellipses show a superior behavior for vanishing noise, PEAC outperforms ellipse fits at higher noise levels. We observe that substantial bias is confined to a narrow region around degeneracy, where , and increases linearly with . In this region, the increased ambiguity in the fit parameters and results in larger bias and increased phase uncertainty . Therefore, despite the expectation from Gaussian uncertainty propagation, the minimal phase uncertainty is not observed at the degeneracy point , i.e., at vanishing signal amplitude. Minimal uncertainty is reached near, but not at the aforementioned degeneracy point, namely, where the signal amplitude is small but still finite. These insights allow us to define the working point to be that phase with no substantial bias and lowest phase uncertainty (see Fig. 5D green arrow). From our baseline-noise scan, we infer that the working point is in close proximity to the transition from a single-peak to a double-peak PDF. At this point, the level of uncertainty is similar to that of ellipse fitting, but the trueness is superior for nonvanishing baseline noise. Our analysis in the Supplementary Materials further indicates that this working point exhibits a linear scaling with . In addition and to establish a robust criterion for when an estimate can be trusted, we also normalize the bias in units of uncertainty in the Supplementary Materials, demonstrating that PEAC remains reliable throughout the entire interval in contrast to ellipses.
Naturally, these results depend not only on the specific noise and noise model but also on the chosen method of parameter estimation from a given PDF. In this article, we use a standard least-squares-based fitting routine because of its simplicity and numerical performance. However, other methods such as maximum likelihood estimation can provide better results. To compare these two approaches, we perform an analysis of bias and uncertainty in analogy to Fig. 5 (C and D) based on maximum likelihood estimation in the Supplementary Materials. In summary, we observe that this approach reduces both bias and uncertainty even further, albeit at the cost of a substantial increase in computational time. Given this trade-off, we have used least-squares-based fitting for our primary evaluation. However, the Supplementary Materials demonstrates that PEAC is inherently compatible with more sophisticated inference techniques and therefore compatible with further future improvements.
DISCUSSION
Although the statistical analysis of the noisy signal of an interferometer, such as histogram-based estimation of the underlying PDF, provides access to the oscillation amplitude and baseline fluctuations, it inherently lacks phase information. When two such signals are correlated, common-mode noise is suppressed, allowing for the extraction of a differential phase from the bivariate data, e.g., from fitting to ellipses (33–35, 78–81) or Lissajous curves (17, 85).
In this work, we establish a geometric connection between these two paradigms: We introduce PEAC, a method that performs a statistical analysis along a suitably chosen projection direction in the bivariate plane. It extracts a differential phase from the observed amplitude, which shows a characteristic collapse and revival due to the beat of overlaying signals. Unlike conventional ellipse fitting, which becomes ill-posed near degeneracy points () where the ellipse collapses to a noisy line (81), PEAC always applies a statistical inference technique to the marginal distribution. This procedure eliminates the issues of a geometric degeneracy and reduces systematic bias, thereby enhancing trueness and overall accuracy. We highlight five key advancements:
1) PEAC allows extracting differential phases and amplitudes in setups where the individual signals cannot be resolved independently, e.g., in nonstate-selective setups where the individual components overlap spatially, overcoming one limitation of conventional ellipse fitting. While we demonstrated PEAC by scanning the differential phase in the “PEAC methodology” section to characterize the signal, such a scan is not a mandatory requirement. Provided that the system’s relevant parameters, such as the weights and the intrinsic amplitude , are determined through independent measurements or initial calibrations, the differential phase can be inferred without an explicit scan. This flexibility is particularly advantageous in tests of fundamental physics or quantum clock interferometry, where the measurand may be minute and modulation of the differential phase is often experimentally impractical.
2) It is a complementary analysis applicable to any system employing ellipse fitting without the need for additional experimental resources. While it generally requires more data points than ellipse fitting due to its statistical nature, PEAC becomes a powerful tool when sufficient statistics are available. It generalizes naturally by projecting along an angle in the bivariate plane, enabling phase estimation of arbitrary mixtures of the correlated signals. For a given set of bivariate data, one can always perform PEAC along a different angle in addition to ellipse fitting (see the “Correlation measurements—Connection to ellipse fitting” section in combination with the Supplementary Materials) to improve the trueness of the estimated phase by reducing the bias and systematic error near degeneracy. While ellipse-based estimation is typically only unbiased at circular degeneracy points ( and odd multiples), PEAC provides a vanishing bias throughout the interval of , except for a region of around degeneracy. Consequently, PEAC is beneficial when the differential phase cannot be precisely controlled. Furthermore, in the “Correlation measurements—Connection to ellipse fitting” section, all parameters of the PDF were determined from independent measurements, experimentally demonstrating that differential phase estimation is possible without the necessity of controlling or scanning the measurand. A reduced bias closer to degeneracy is not merely a technical improvement but critical for high-accuracy null measurements, e.g., envisioned for tests of fundamental physics (7–10).
3) We demonstrate that PEAC directly connects to quantum clock interferometry (39–44) and answers the question of the optimal working point, which in fact is close to, but not exactly at, degeneracy. Notably, we observe no divergence of phase sensitivity close to degeneracy, as predicted from geometric phase amplification (51) when neglecting the vanishing oscillation amplitude or from Gaussian uncertainty propagation. Even in the context of fundamental physics applications, where one typically probes null signals or minute phase shifts and therefore has limited flexibility to access regimes with substantial amplitude collapse, PEAC has practical implications, as outlined above. Furthermore, recent quantum clock experiments using magnetic field gradients to measure geometric phases (51) have observed a considerable reduction in contrast, highlighting the relevance of such methods in realistic scenarios.
4) Beyond two correlated signals, we demonstrate the applicability of PEAC to three correlated signals, without requiring to resolve them individually, by the example of a mixture of three magnetic sublevels. The technique is therefore established as a complementary analysis of three- or higher-dimensional ellipse methods (76) by analyzing histograms along the semi-axes. Moreover, it can be applied to scenarios where an amplitude modulation is introduced deliberately into only one signal, situations that are inaccessible to ellipse fitting. For example, we extend contrast-envelope fits (58–60), a standard technique for atom interferometry, where the interferometer is partially or dynamically opened to control the visibility of the interference pattern. Similarly, it applies to schemes where a phase modulation translates into a characteristic amplitude modulation (86).
5) Last, PEAC is broadly applicable to a wide range of setups, from fully phase stable to noisy, phase-unstable regimes. The sensitivity of phase estimation can be enhanced by resorting to higher-order atom diffraction, demonstrating that it scales with increasing momentum transfer and can be applied to periodic signals beyond atom interferometry, such as atomic clocks (55, 56) or optical interferometers. Moreover, the statistical nature of the method offers potential for integration into hybrid classical-quantum sensors (87) or for locking devices to a regime of minimal phase uncertainty (88).
We identified a working point for PEAC at phases close to, but not exactly at, degeneracy. Using a numerical model and associated parameter scans, we showed that its exact location depends approximately linearly on the strength of baseline fluctuations. However, although a preferred phase of operation exists, PEAC remains applicable even when the differential phase cannot be sufficiently controlled. In this case, ellipse fitting exhibits a substantial bias across all phases except at , exceeding the statistical uncertainty, whereas PEAC yields a bias-free estimate except in a narrow region around degeneracy. By contrast, in the idealized absence of baseline fluctuations, ellipse fitting outperforms PEAC, as demonstrated by our numerical analysis.
Moving beyond the least-squares fitting of PDFs used in the main text, PEAC can be further improved by combining it with alternative statistical inference techniques, such as maximum likelihood estimation (89) discussed in the Supplementary Materials. Furthermore, it can be integrated with other approaches such as Bayesian methods (17, 54, 90). As these techniques pose a more targeted approach to parameter estimation, we anticipate a further reduction of the bias. Similarly, PEAC can be combined with recent developments in ellipse fitting, such as geometric procedures that minimize the bias with the help of optimized cost functions (21). Using PEAC in combination with ellipse fitting and inducing a feedback loop between these procedures can help to decrease the bias in a joint phase estimation protocol, especially close to degeneracy. One could further allow for adaptive bin sizes within a single histogram and automatically assess the number of required bins to resolve the important features of the PDF without increasing the statistics. Such a procedure would also lead to improved initial guesses for the fitting routines. PEAC is a classical statistical method, and the presented experimental results are obtained in a setup limited by technical noise one order of magnitude above shot noise. Further reducing technical noise sources leads to a regime in which the sensitivity is limited by quantum projection noise, i.e., shot noise. In this case, the signal is no longer homoscedastic, and PEAC must be adapted accordingly. At the same time, this regime constitutes the prerequisite for quantum-enhanced metrology. Combining PEAC with quantum input states, such as optimally squeezed states (84), has the potential to surpass current limits in quantum metrology and to advance perspectives in a broad range of applications.
MATERIALS AND METHODS
Experimental system and measurements
Our experimental setup produces BECs in a CDT by forced evaporative cooling (62, 91). To perform measurements in free space, the atoms are released from the CDT into free fall. Prior to the start of the MZI sequence, an expansion time of allows for the conversion of the mean-field to kinetic energy. After this expansion, typically (63) the momentum spread of the ensemble is . The laser beams used for Bragg diffraction are superimposed onto one of the CDT beams in a counter-propagating setup, oriented perpendicular to the direction of gravity. This ensures an initial momentum of in the direction of Bragg diffraction. To drive two-photon transitions, the Bragg beams are detuned by from the excited state manifold , transferring momentum along the Bragg axis. For the results presented in this article, we rely on first-order Bragg diffraction by choosing a detuning between the two beams, while our setup also allows for higher-order diffraction (63) by adjusting to other resonances. A Blackman window function for as a smooth pulse shape ensures efficient transfer between the coupled momentum states and reduces the population of parasitic momenta. We use a pulse length of as a compromise between velocity selectivity and diffraction efficiency, adjusting the peak Rabi frequency of the three pulses to adapt for the pulse configuration. Following each MZI, a TOF of typically is applied to separate the two interferometer ports spatially for detection. We perform resonant absorption imaging (92) of the atomic densities to gain access to the atom numbers and in each of the interferometer ports. Without optical pumping or a state-selective SG measurement, the densities of the three substates will spatially overlap and cannot be distinguished. However, our setup also allows using the SG method by applying a magnetic field gradient after the MZI, generated by one of the magnetic coils used for the magneto-optical trap, separating the substates spatially via the Zeeman force. A time delay of between the second pulse and the introduction of the magnetic field gradient prevents spurious phase contributions to the interferometer phase. The applied weak gradient is left on for a total of until detection to ensure proper state separation.
Derivation of signal S
The normalized difference between the atom numbers with detected in the two momentum classes leads to the signal
| (7) |
introducing the mean and differential baseline and , as well as the mean and differential amplitude and , respectively. With only two exit ports, the total atom number must be preserved and independent of the interferometric phase , implying . As a result, we find
| (8) |
In general, are suitable random variables describing experimental stochastic fluctuations of baselines and amplitudes, which may cause a heteroscedastic signal. It is typically assumed that the baseline noise is normally distributed and dominant, such that can be treated as constant (54). Observing a homoscedastic signal, i.e., in our setting treating as constant, is possible if both random variables are correlated. Assuming that and are perfectly correlated gives
| (9) |
where denotes the expectation value and the variance of a random variable. To have constant and excluding the trivial constant signal, i.e., , the condition
| (10) |
must be satisfied. With Eq. 10, we observe from the condition of perfect correlation (9) that the signal takes the form
| (11) |
in which only fluctuates.
Assuming normally distributed baselines with mean and standard deviation , for resolving a signal, the fluctuations must be sufficiently small, i.e., . If we additionally assume the same baseline fluctuations in both exits of the interferometer, i.e., , then we can treat the mean baseline as constant with and . With these stipulations we finally arrive at a homoscedastic signal
| (12) |
with of mean and variance , and , that has no amplitude fluctuations and only normally distributed baseline fluctuations.
Finite-pulse duration
The finite duration of the Bragg pulses can be a substantial fraction of the interferometer time , ranging from 3% up to 10% in our experiments and therefore introduces a non-negligible phase contribution (68, 93–95) that must be included in our phase analysis. To incorporate this phase contribution, we resort to a numerical treatment, necessary for time-dependent pulses and define the accumulated time-dependent pulse area
| (13) |
with the time-dependent Rabi frequency train described by the Blackman envelope . As in the experiment, we choose accounting for the pulses at and and for the pulse at . An external acceleration induces a time-dependent Doppler detuning , assuming that the atoms are initially on resonance in agreement with our experimental realization. For example, to obtain the phase of the state induced by , we evaluate (68)
| (14) |
numerically for and various . For a simplified analytical expression, we fit to the resulting values and obtain the fit parameter .
General amplitude modulation
Here, we present the derivation of the amplitude modulation in Eq. 3 of the main text. A sum of cosine functions weighted by with a common phase , but possible different phases , results (96) in
| (15a) |
with the modulated amplitude
| (15b) |
and offset phase
| (15c) |
In our setting we have , , and , such that after algebraic manipulations, we obtain Eq. 3 of the main text and find for the offset phase
| (16) |
A pointwise phase reconstruction is possible if all are known and can be obtained from
| (17) |
where we introduced .
Histogram fitting routine
We generate all histograms by binning the 300 measurements of each signal into bins. The width of the bins for each setting is adapted so that all 18 bins cover the whole range of acquired data and therefore depends on the signal’s maximum value. This change of bin size can be seen in Figs. 3B and 4. The square root rule is an established rule for creating histograms with an adequate resolution in our setting, although we note that this is not a trivial matter and leaves plenty of room for refinement (97, 98).
Probability density function
We start from the signal form of the main text, i.e., , where is a constant amplitude, is a (potentially fluctuating) phase that is used to scan a fringe, is a fixed phase, and is a normally distributed random variable describing baseline fluctuations.
At the same time, fluctuations of translate into a PDF for the observed amplitude (99)
| (18) |
if one assumes a uniform phase distribution with support . By linearly scanning in our experiment, we ensure that this uniform phase distribution is a good approximation, even in the absence of phase fluctuations, i.e., for short . However, any underlying PDF of can be used to adapt .
Moreover, we assume that baseline fluctuations are independent and identically distributed, such that their PDF is given by a normal distribution
| (19) |
with mean and variance , according to the central limit theorem. The PDF of a sum of two random variables is the convolution of their respective PDFs, i.e., the PDF of the signal is
| (20) |
For , this PDF shows a symmetric double-peak distribution. These maxima are roughly separated by , their width is determined by , and the PDF rapidly decays for . Contrary, for , the two maxima start to overlap, causing the double-peak structure to become washed out.
Initial guesses
For fitting the histogram’s PDF, see Eq. 5, we use scipy.optimize.curve_fit from the scipy package in python (100), returning , , and . To guarantee reliable convergence of the fit, accurate initial parameter guesses are essential. Note that the scipy.optimize.curve_fit method is based on a gradient approach, which is computationally efficient; however, the PDF is not differentiable with respect to even in a distributional sense. We noticed issues related to this nondifferentiability when using poor initial guesses.
The initial guess of the histogram’s mean is given by explicitly calculating the signal’s mean. A reliable initial guess for the standard deviation of the baseline fluctuations can be extracted from the rapid decay of the PDF: First, we determine one maximum of the histogram at . Starting from this maximum, we scan outward across the histogram to locate the position with , where the maximum has dropped to the fraction . We then roughly approximate the rapid outward drop of the histogram by an exponential decay, resulting in
| (21) |
which is well-defined since . The choice gave robust and reliable initial guesses.
The initial guess of the amplitude is obtained from the above guesses via
| (22) |
We numerically confirmed that , up to numerical factors. An analytical form is only possible for , where we find as expected.
Fitting procedure
When fitting a single histogram, we make use of the initial guesses according to the “Initial guesses” section. In the state-selective case, we have access to , , and , such that we can perform four histogram fits. We start by fitting the histogram’s PDF to based on the initial guesses from the previous section, returning , , and . We set to be the mean . Next, we use the mean as the initial guess for and , unless it is smaller than any bin width of . In the latter case, we use the initial guess routine of the “Initial guesses” section for and . Both and fluctuate with the same standard deviation , identical to that of , because for , the random variable is also normally distributed, i.e., . Since we have and , we find .
Last, we restrict the parameter to but otherwise estimate the amplitudes as in the “Initial guesses” section. These limits ensure the correct connection between and , allowing for a phase reconstruction via Eq. 5.
We apply the same procedure to the difference signal, but use for phase reconstruction. Unlike the amplitude and standard deviation of the baseline fluctuations, the mean is not an issue. Therefore, we use the mean of the respective signal as the initial guess.
Ellipse fitting routine
As a comparison to PEAC, we deploy an established approach to evaluate correlated signals based on fitting an ellipse to a bivariate parametric plot of two signals. We assume that the signals of the substates have the parametric form with amplitudes , baselines , common phase , and differential phase . The bivariate data span ellipses in the plane, where the eccentricity of the ellipse encodes the differential phase. We translate the parametric form into the algebraic description of conic sections with the coefficients
| (23) |
which for ellipses have to satisfy for . For the ellipse degenerates onto straight lines in the case of perfect correlation or anti-correlation. The direct evaluation of Eq. 8 gives access to the differential phase
| (24) |
As mentioned in the main text, diagonalizing the quadratic form and assuming equal amplitudes implying leads to the two principal axes of the ellipse along the and direction of the bivariate coordinate space, i.e., the diagonal and antidiagonal depending on the sign of .
Expressed in the bivariate plane, the signal for is
| (25) |
Clearly, this equation describes an ellipse with semi-axes along the diagonal/antidiagonal of the bivariate plane. Hence, we perform a geometric fit to general form
| (26) |
where are the moduli of the semi-axes and is the ellipse’s rotation angle in the bivariate plane. Using Eq. 15 to cast this into the form of Eq. 25 gives
| (27) |
This form of the differential phase allows using the two-argument arctangent of many programming languages. Minimizing the sum of the squared Euclidean distance gives rise to the so-called geometric ellipse fits (81, 82, 84). We use scipy.optimize.least_squares and scipy.optimize.minimize_scalar for this minimization process with the physical bounds , , and as we work with normalized signals. Because of its computational low cost, we use the Halíř and Flusser algorithm (79, 80) to fit the algebraic ellipse Eq. 23 to our data as an initial guess for the computationally more demanding geometric ellipse fits.
Bootstrapping
We assume that the experimental uncertainties of the homoscedastic interferometric signals stem from fluctuations of the signal’s baseline , parametrized by the standard deviation of a normal distribution in our model, while the amplitude of the signal is assumed to be constant. Since for any interferometer time we fit the PDF to all recorded data points, no uncertainty of this procedure can be extracted in a direct way. To estimate the uncertainties of measured quantities, we therefore implement a bootstrapping approach (71, 72, 101), assuming that our data provide a representative sample of the underlying probability distribution. For each interferometer time , we use all 300 available data points and randomly draw a set of 300 data points with replacement. In addition to the original data, we generate 999 random sets, giving us access to 1000 independent datasets per , each comprising 300 points. These datasets are then used to obtain the quantities of interest such as the amplitude or the differential phase via least-square fitting methods. Based on the extracted values, we compute mean and standard deviations for each quantity, which are reported in the main body of this article.
To validate the reliability of the bootstrapping procedure, we compare it against randomly generated numerical datasets. We find no substantial difference in the standard deviations between random and bootstrapped datasets.
Numerical replication
To investigate properties such as the bias or the uncertainty with finer resolution than experimentally being accessible with reasonable effort, we resort to a numerical replication of our experiment. For the numerically generated data, we use the amplitude and baseline fluctuations extracted from the experimental datasets, setting the mean baseline offset , since it corresponds to a translation that can be neglected. Similar to bootstrapping the experimental data, we produce 1000 numerical datasets containing 300 randomly generated values for each phase of interest. Here, we markedly increase the sampling of compared to the experiment to give access to finer details. Each random value of is computed by sampling a random phase and a baseline value drawn from a normal distribution with mean and variance . We implement the random number generation using the numpy.random.default_rng.uniform and numpy.random.default_rng.normal functions of the numpy package in python (102, 103). By producing 1000 individual datasets, rather than bootstrapping a single set, as it was done with the experimental data, we can check whether a systematic effect is apparent in the bootstrapping procedure itself, which assumes that the experimental sample size is sufficient to describe the underlying PDF. In our case, we find no systematic difference between the bootstrapped experimental data and numerically generated random data, hence we observe no systematic effects.
Origin of a bias in PEAC
We identified three main challenges that cause a bias in PEAC: (i) the signal’s amplitude becomes comparable to the standard deviation of the baseline fluctuations ; (ii) the true amplitude is close to the fit boundaries; and (iii) resolution limits imposed by bin size. In contrast to ellipse fits at the points of degeneracy, where the algebraic structure reduces to a line and fitting data to an ellipse is ill-posed, the underlying PDF used in PEAC is correct for all differential phases. Thus, the observed bias is not intrinsic to PEAC, but reflects limitations of any fit procedure in regimes of ambiguous parameters, parameters close to boundaries, or a finite resolution.
Addressing (i): Because of the amplitude modulation, the PDF of the histogram transitions from a double-peak to a single-peak distribution, as the two maxima begin to overlap until only one maximum remains, depending on the differential phase. Although no analytical form exists for this transition, we numerically found a threshold at . Below this limit, two equally plausible fits are possible because of the ambiguity in the combination of and . This ambiguity leads to a wider spread in the amplitude values , resulting in a wider spread of and by that increasing its uncertainty . Consequently, the true amplitude value becomes less likely, resulting in a distorted distribution overestimating the mean. A maximum likelihood estimation (89) instead or a Bayesian inference strategy (17, 54, 90) could in principle be used to mitigate this issue.
Addressing (ii): To ensure consistency between and , we impose the fit limits . For example, the upper limit guarantees that a phase reconstruction via Eq. 5 is possible, as higher amplitudes imply values outside the domain of the function. However, this constrain leads to a truncated distribution of fit parameters, whose mean underestimates the true amplitude value. Over- and underestimating are general limitations of any fit routine with physical or logical bounds of the fit parameters.
Addressing (iii): We use a fixed number of 18 bins, but the range of signal values and changes with the differential phase because of the modulation of and . A wider range of values implies bigger bin sizes reducing the fit resolution. In combination with (ii), this effect is most likely the reason for the bias in the difference signal (along the major axis) being bigger than the bias in the sum signal (along the minor axis) at .
Acknowledgments
We thank S. Abend, F. Di Pumpo, A. Friedrich, S. Kanthak, M. Meister, and D. Reinhard for stimulating discussions and suggestions. We acknowledge contributions from the Terrestrial Very-Long-Baseline Atom Interferometry (TVLBAI) proto-collaboration.
Funding:
The QUANTUS-VI project is supported by the German Space Agency at the German Aerospace Center [Deutsche Raumfahrtagentur im Deutschen Zentrum für Luft- und Raumfahrt (DLR)] with funds provided by the Federal Ministry for Economic Affairs and Climate Action [Bundesministerium für Wirtschaft und Klimaschutz (BMWK)] due to an enactment of the German Bundestag under grant no. 50WM2450E (QUANTUS-VI). The grant recipient is E.G., and this funding supports the position of D.D.
Author contributions:
Conceptualization: E.G., G.B., D.D. (supporting), and D.P. (supporting). Data curation: D.D., D.P., and L.L. (supporting). Formal analysis: D.D., D.P., and L.L. (supporting). Funding acquisition: E.G. and G.B. Investigation: D.D., D.P., and L.L. (supporting). Methodology: D.D., D.P., E.G. (supporting), and G.B. (supporting). Software: D.D., D.P., and L.L. (supporting). Supervision: E.G. and G.B. Validation: D.D., D.P., L.L., E.G., and G.B. Visualization: D.D., D.P., E.G. (supporting), and G.B. (supporting). Writing—original draft: D.D., D.P., and E.G. (supporting). Writing—review and editing: D.D., D.P., E.G., G.B., and L.L. (supporting).
Competing interests:
The authors declare that they have no competing interests.
Data, code, and materials availability:
All data and code needed to evaluate and reproduce the results in the paper are present in the paper, the Supplementary Materials, and a publicly accessible online repository at www.doi.org/10.5281/zenodo.21340342 based on https://github.com/TU-Darmstadt-APQ/PEAC.git. This study did not generate new materials.
Supplementary Materials
This PDF file includes:
Sections S1 to S5
Figs. S1 to S8
REFERENCES
- 1.Morel L., Yao Z., Cladé P., Guellati-Khélifa S., Determination of the fine-structure constant with an accuracy of 81 parts per trillion. Nature 588, 61–65 (2020). [DOI] [PubMed] [Google Scholar]
- 2.Parker R. H., Yu C., Zhong W., Estey B., Müller H., Measurement of the fine-structure constant as a test of the Standard Model. Science 360, 191–195 (2018). [DOI] [PubMed] [Google Scholar]
- 3.Arvanitaki A., Graham P. W., Hogan J. M., Rajendran S., Van Tilburg K., Search for light scalar dark matter with atomic gravitational wave detectors. Phys. Rev. D 97, 075020 (2018). [Google Scholar]
- 4.Derr D., Giese E., Clock transitions versus Bragg diffraction in atom-interferometric dark-matter detection. AVS Quantum Sci. 5, 044404 (2023). [Google Scholar]
- 5.Abend S., Allard B., Alonso I., Antoniadis J., Araújo H., Arduini G., Arnold A. S., Asano T., Augst N., Badurina L., Balaž A., Banks H., Barone M., Barsanti M., Bassi A., Battelier B., Baynham C. F. A., Beaufils Q., Belić A., Beniwal A., Bernabeu J., Bertinelli F., Bertoldi A., Biswas I. A., Blas D., Boegel P., Bogojević A., Böhm J., Böhringer S., Bongs K., Bouyer P., Brand C., Brimis A., Buchmueller O., Cacciapuoti L., Calatroni S., Canuel B., Caprini C., Caramete A., Caramete L., Carlesso M., Carlton J., Casariego M., Charmandaris V., Chen Y.-A., Chiofalo M. L., Cimbri A., Coleman J., Constantin F. L., Contaldi C. R., Cui Y., Ros E. D., Davies G., del Pino Rosendo E., Deppner C., Derevianko A., de Rham C., De Roeck A., Derr D., Di Pumpo F., Djordjevic G. S., Döbrich B., Domokos P., Dornan P., Doser M., Drougakis G., Dunningham J., Duspayev A., Easo S., Eby J., Efremov M., Ekelof T., Elertas G., Ellis J., Evans D., Fadeev P., Fanì M., Fassi F., Fattori M., Fayet P., Felea D., Feng J., Friedrich A., Fuchs E., Gaaloul N., Gao D., Gardner S., Garraway B., Gauguet A., Gerlach S., Gersemann M., Gibson V., Giese E., Giudice G. F., Glasbrenner E. P., Gündoğan M., Haehnelt M., Hakulinen T., Hammerer K., Hanımeli E. T., Harte T., Hawkins L., Hees A., Heise J., Henderson V. A., Herrmann S., Hird T. M., Hogan J. M., Holst B., Holynski M., Hussain K., Janson G., Jeglič P., Jelezko F., Kagan M., Kalliokoski M., Kasevich M., Kehagias A., Kilian E., Koley S., Konrad B., Kopp J., Kornakov G., Kovachy T., Krutzik M., Kumar M., Kumar P., Lämmerzahl C., Landsberg G., Langlois M., Lanigan B., Lellouch S., Leone B., Le Poncin-Lafitte C., Lewicki M., Leykauf B., Lezeik A., Lombriser L., Lopez-Gonzalez J. L., Asamar E. L., Monjaraz C. L., Luciano G. G., Mahmoud M. A., Maleknejad A., Krutzik M., Marteau J., Massonnet D., Mazumdar A., Cabe C. M., Meister M., Menu J., Messineo G., Micalizio S., Millington P., Milosevic M., Mitchell J., Montero M., Morley G. W., Müller J., Müstecapl ioğlu Ö. E., Ni W.-T., Noller J., Odžak S., Oi D. K. L., Omar Y., Pahl J., Paling S., Pandey S., Pappas G., Pareek V., Pasatembou E., Pelucchi E., Pereira dos Santos F., Piest B., Pikovski I., Pilaftsis A., Plunkett R., Poggiani R., Prevedelli M., Puputti J., Veettil V. P., Quenby J., Rafelski J., Rajendran S., Rasel E. M., Sfar H. R., Reynaud S., Richaud A., Rodzinka T., Roura A., Rudolph J., Sabulsky D. O., Safronova M. S., Santamaria L., Schilling M., Schkolnik V., Schleich W. P., Schlippert D., Schneider U., Schreck F., Schubert C., Schwersenz N., Semakin A., Sergijenko O., Shao L., Shipsey I., Singh R., Smerzi A., Sopuerta C. F., Spallicci A. D. A. M., Stefanescu P., Stergioulas N., Ströhle J., Struckmann C., Tentindo S., Throssell H., Tino G. M., Tinsley J. N., Mircea O. T., Tkalčec K., Tolley A. J., Tornatore V., Torres-Orjuela A., Treutlein P., Trombettoni A., Tsai Y.-D., Ufrecht C., Ulmer S., Valuch D., Vaskonen V., Vázquez-Aceves V., Vitanov N. V., Vogt C., von Klitzing W., Vukics A., Walser R., Wang J., Warburton N., Webber-Date A., Wenzlawski A., Werner M., Williams J., Windpassinger P., Wolf P., Woerner L., Xuereb A., Yahia M. E., Cruzeiro E. Z., Zarei M., Zhan M., Zhou L., Zupan J., Zupanič E., Terrestrial very-long-baseline atom interferometry: Workshop summary. AVS Quantum Sci. 6, 024701 (2024). [Google Scholar]
- 6.Abdalla A., Abe M., Abend S., Abidi M., Aidelsburger M., Alibabaei A., Allard B., Antoniadis J., Arduini G., Augst N., Balamatsias P., Balaž A., Banks H., Barcklay R. L., Barone M., Barsanti M., Bason M. G., Bassi A., Bayle J.-B., Baynham C. F. A., Beaufils Q., Beldjoudi S., Belić A., Bennetts S., Bernabeu J., Bertoldi A., Bigard C., Bigelow N. P., Bingham R., Blas D., Bobrick A., Boehringer S., Bogojević A., Bongs K., Bortoletto D., Bouyer P., Brand C., Buchmueller O., Buica G., Calatroni S., Calmels L., Canizares P., Canuel B., Caramete A., Caramete L.-I., Carlesso M., Carlton J., Carman S. P., Carroll A., Casariego M., Chairetis M., Charmandaris V., Chauhan U., Chen J., Chiofalo M. L., Ciampini D., Cimbri A., Cladé P., Coleman J., Constantin F. L., Contaldi C. R., Corgier R., Dash B., Davies G. J., de Rham C., De Roeck A., Derr D., Dey S., Di Pumpo F., Djordjevic G. S., Döbrich B., Dornan P., Doser M., Drougakis G., Dunningham J., Duspayev A., Easo S., Eby J., Efremov M., Elertas G., Ellis J., Entin N., Fairhurst S., Fanì M., Fassi F., Fayet P., Felea D., Feng J., Flack R., Foot C., Freegarde T., Fuchs E., Gaaloul N., Gao D., Gardner S., Garraway B. M., Garrido Alzar C. L., Gauguet A., Giese E., Gill P., Giudice G. F., Glasbrenner E. P., Glick J., Graham P. W., Granados E., Griffin P. F., Gué J., Guellati-Khelifa S., Gupta S., Gupta V., Hackermueller L., Haehnelt M., Hakulinen T., Hammerer K., Hanımeli E. T., Harte T., Hartmann S., Hawkins L., Hees A., Herbst A., Hird T. M., Hobson R., Hogan J., Holst B., Holynski M., Hosten O., Hsu C. C., Huang W. C.-W., Hughes K. M., Hussain K., Hütsi G., Iovino A., Isfan M.-C., Janson G., Jeglič P., Jetzer P., Jiang Y., Juzeliūnas G., Kaenders W., Kalliokoski M., Kehagias A., Kilian E., Klempt C., Knight P., Koley S., Konrad B., Kovachy T., Krutzik M., Kumar M., Kumar P., Labiad H., Lan S.-Y., Landragin A., Landsberg G., Langlois M., Lanigan B., Leone B., Le Poncin-Lafitte C., Lellouch S., Lewicki M., Lien Y.-H., Lombriser L., Asamar E. L., Lopez-Gonzalez J. L., Lu C., Luciano G. G., Lundblad N., de J. López Monjaraz C., Lowe A., Mackoit-Sinkevičienė M., Maggiore M., Majumdar A., Makris K., Maleknejad A., Marchant A. L., Mariotti A., Markou C., Matthews B., Mazumdar A., Cabe C. M., Meister M., Mentasti G., Menu J., Messineo G., Meyer-Hoppe B., Micalizio S., Migliaccio F., Millington P., Milosevic M., Mishra A., Mitchell J., Morley G. W., Mouelle N., Müller J., Newbold D., Ni W.-T., Niehof C., Noller J., Odžak S., Oi D. K. L., Oikonomou A., Omar Y., Overstreet C., Veettil V. P., Pahl J., Paling S., Pan Z., Pappas G., Pareek V., Pasatembou E., Paternostro M., Pathak V. K., Pelucchi E., Pereira dos Santos F., Peters A., Pichery A., Pikovski I., Pilaftsis A., Pislan F.-C., Plunkett R., Poggiani R., Prevedelli M., Rafelski J., Raidal J., Raidal M., Rasel E. M., Renaux-Petel S., Richaud A., Rivero-Antunez P., Rodzinka T., Roura A., Rudolph J., Sabulsky D., Safronova M. S., Sakellariadou M., Salvi L., Sameed M., Sarkar S., Schach P., Schäffer S. A., Schelfhout J., Schilling M., Schkolnik V., Schleich W. P., Schlippert D., Schneider U., Schreck F., Schwartzman A., Schwersenz N., Sergijenko O., Sfar H. R., Shao L., Shipsey I., Shu J., Singh Y., Sopuerta C. F., Sorba M., Sorrentino F., Spallicci A. D. A. M., Stefanescu P., Stergioulas N., Stoerk D., Sunilkumar H. T., Ströhle J., Tam Z., Tandon D., Tang Y., Tell D., Tempere J., Temples D. J., Thampy R. P., Tietje I. C., Tino G. M., Tinsley J. N., Mircea O. T., Tkalčec K., Tolley A. J., Tornatore V., Torres-Orjuela A., Treutlein P., Trombettoni A., Ufrecht C., Urrutia J., Valenzuela T., Valerio L. R., van der Grinten M., Vaskonen V., Vázquez-Aceves V., Veermäe H., Vetrano F., Vitanov N. V., von Klitzing W., Wald S., Walker T., Walser R., Wang J., Wang Y., Weidner C. A., Wenzlawski A., Werner M., Wörner L., Yahia M. E., Yazgan E., Cruzeiro E. Z., Zarei M., Zhan M., Zhang S., Zhou L., Zupanič E., Terrestrial very-long-baseline atom interferometry: Summary of the second workshop. EPJ Quantum Technol. 12, 42 (2025). [Google Scholar]
- 7.Rosi G., Sorrentino F., Cacciapuoti L., Prevedelli M., Tino G. M., Precision measurement of the Newtonian gravitational constant using cold atoms. Nature 510, 518–521 (2014). [DOI] [PubMed] [Google Scholar]
- 8.Lamporesi G., Bertoldi A., Cacciapuoti L., Prevedelli M., Tino G. M., Determination of the newtonian gravitational constant using atom interferometry. Phys. Rev. Lett. 100, 050801 (2008). [DOI] [PubMed] [Google Scholar]
- 9.Fixler J. B., Foster G. T., McGuirk J. M., Kasevich M. A., Atom interferometer measurement of the newtonian constant of gravity. Science 315, 74–77 (2007). [DOI] [PubMed] [Google Scholar]
- 10.Pikovski I., Zych M., Costa F., Brukner Č., Universal decoherence due to gravitational time dilation. Nat. Phys. 11, 668–672 (2015). [Google Scholar]
- 11.Schlippert D., Hartwig J., Albers H., Richardson L. L., Schubert C., Roura A., Schleich W. P., Ertmer W., Rasel E. M., Quantum test of the universality of free fall. Phys. Rev. Lett. 112, 203002 (2014). [Google Scholar]
- 12.Asenbaum P., Overstreet C., Kim M., Curti J., Kasevich M. A., Atom-interferometric test of the equivalence principle at the 10−12 level. Phys. Rev. Lett. 125, 191101 (2020). [DOI] [PubMed] [Google Scholar]
- 13.Barrett B., Antoni-Micollier L., Chichet L., Battelier B., Lévèque T., Landragin A., Bouyer P., Dual matter-wave inertial sensors in weightlessness. Nat. Commun. 7, 13786 (2016). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Schaffrath S., Störk D., Di Pumpo F., Giese E., Unified laboratory-frame analysis of atomic gravitational-wave sensors. AVS Quantum Sci. 7, 044402 (2025). [Google Scholar]
- 15.Yu N., Tinto M., Gravitational wave detection with single-laser atom interferometers. Gen. Relativ. Gravit. 43, 1943–1952 (2011). [Google Scholar]
- 16.Chaibi W., Geiger R., Canuel B., Bertoldi A., Landragin A., Bouyer P., Low frequency gravitational wave detection with ground-based atom interferometer arrays. Phys. Rev. D 93, 021101 (2016). [Google Scholar]
- 17.Barrett B., Antoni-Micollier L., Chichet L., Battelier B., Gominet P.-A., Bertoldi A., Bouyer P., Landragin A., Correlative methods for dual-species quantum tests of the weak equivalence principle. New J. Phys. 17, 085010 (2015). [Google Scholar]
- 18.Barrett B., Condon G., Chichet L., Antoni-Micollier L., Arguel R., Rabault M., Pelluet C., Jarlaud V., Landragin A., Bouyer P., Battelier B., Testing the universality of free fall using correlated 39K-87Rb atom interferometers. AVS Quantum Sci. 4, 014401 (2022). [Google Scholar]
- 19.Bongs K., Holynski M., Vovrosh J., Bouyer P., Condon G., Rasel E., Schubert C., Schleich W. P., Roura A., Taking atom interferometric quantum sensors from the laboratory to real-world applications. Nat. Rev. Phys. 1, 731–739 (2019). [Google Scholar]
- 20.Elliott E. R., Aveline D. C., Bigelow N. P., Boegel P., Botsi S., Charron E., D’Incao J. P., Engels P., Estrampes T., Gaaloul N., Kellogg J. R., Kohel J. M., Lay N. E., Lundblad N., Meister M., Mossman M. E., Müller G., Müller H., Oudrhiri K., Phillips L. E., Pichery A., Rasel E. M., Sackett C. A., Sbroscia M., Schleich W. P., Thompson R. J., Williams J. R., Quantum gas mixtures and dual-species atom interferometry in space. Nature 623, 502–508 (2023). [DOI] [PubMed] [Google Scholar]
- 21.Meister M., Müller G., Boegel P., Roura A., Pichery A., Reinhardt D. B., Estrampes T., Ströhle J., Giese E., Ahlers H., Herr W., Schubert C., Charron É., Müller H., Williams J. R., Rasel E. M., Schleich W. P., Gaaloul N., Bigelow N. P., Magnetometry with a space-based differential atom interferometer. Nat. Commun. 17, 6089 (2026). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Hardman K. S., Everitt P. J., Donald G. D. M., Manju P., Wigley P. B., Sooriyabandara M. A., Kuhn C. C. N., Debs J. E., Close J. D., Robins N. P., Simultaneous precision gravimetry and magnetic gradiometry with a Bose-Einstein condensate: A high precision, Quantum Sensor. Phys. Rev. Lett. 117, 138501 (2016). [DOI] [PubMed] [Google Scholar]
- 23.Zhou M.-K., Hu Z.-K., Duan X.-C., Sun B.-L., Zhao J.-B., Luo J., Precisely mapping the magnetic field gradient in vacuum with an atom interferometer. Phys. Rev. A 82, 061602 (2010). [Google Scholar]
- 24.Hu Z.-K., Duan X.-C., Zhou M.-K., Sun B.-L., Zhao J.-B., Huang M.-M., Luo J., Simultaneous differential measurement of a magnetic-field gradient by atom interferometry using double fountains. Phys. Rev. A 84, 013620 (2011). [Google Scholar]
- 25.Gustavson T. L., Landragin A., Kasevich M. A., Rotation sensing with a dual atom-interferometer Sagnac gyroscope. Class. Quantum Gravity 17, 2385–2398 (2000). [Google Scholar]
- 26.Berg P., Abend S., Tackmann G., Schubert C., Giese E., Schleich W. P., Narducci F. A., Ertmer W., Rasel E. M., Composite-Light-Pulse Technique for High-Precision Atom Interferometry. Phys. Rev. Lett. 114, 063002 (2015). [DOI] [PubMed] [Google Scholar]
- 27.Canuel B., Leduc F., Holleville D., Gauguet A., Fils J., Virdis A., Clairon A., Dimarcq N., Bordé C. J., Landragin A., P. Bouyer, Six-Axis Inertial Sensor Using Cold-Atom Interferometry. Phys. Rev. Lett. 97, 010402 (2006). [DOI] [PubMed] [Google Scholar]
- 28.Beydler M. M., Moan E. R., Luo Z., Chu Z., Sackett C. A., Guided-wave Sagnac atom interferometer with large area and multiple orbits. AVS Quantum Sci. 6, 014401 (2024). [Google Scholar]
- 29.Sorrentino F., Bodart Q., Cacciapuoti L., Lien Y.-H., Prevedelli M., Rosi G., Salvi L., Tino G. M., Sensitivity limits of a Raman atom interferometer as a gravity gradiometer. Phys. Rev. A 89, 023607 (2014). [Google Scholar]
- 30.Snadden M. J., McGuirk J. M., Bouyer P., Haritos K. G., Kasevich M. A., Measurement of the Earth's Gravity Gradient with an Atom Interferometer-Based Gravity Gradiometer. Phys. Rev. Lett. 81, 971–974 (1998). [Google Scholar]
- 31.Bertoldi A., Lamporesi G., Cacciapuoti L., de Angelis M., Fattori M., Petelski T., Peters A., Prevedelli M., Stuhler J., Tino G. M., Atom interferometry gravity-gradiometer for the determination of the Newtonian gravitational constant G. Eur. Phys. J. D 40, 271–279 (2006). [Google Scholar]
- 32.Dickerson S. M., Hogan J. M., Sugarbaker A., Johnson D. M. S., Kasevich M. A., Multiaxis Inertial Sensing with Long-Time Point Source Atom Interferometry. Phys. Rev. Lett. 111, 083001 (2013). [DOI] [PubMed] [Google Scholar]
- 33.Foster G. T., Fixler J. B., McGuirk J. M., Kasevich M. A., Method of phase extraction between coupled atom interferometers using ellipse-specific fitting. Opt. Lett. 27, 951–953 (2002). [DOI] [PubMed] [Google Scholar]
- 34.Zhang X., Zhong J., Lyu W., Xu W., Zhu L., Wang M., Chen X., Tang B., Wang J., Zhan M., Dependence of the ellipse fitting noise on the differential phase between interferometers in atom gravity gradiometers. Opt. Express 31, 44102–44112 (2023). [DOI] [PubMed] [Google Scholar]
- 35.Fitzgibbon A., Pilu M., Fisher R., Direct least square fitting of ellipses. IEEE Trans. Pattern Anal. Mach. Intell. 21, 476–480 (1999). [Google Scholar]
- 36.Z. L. Szpak, W. Chojnacki, A. van den Hengel, Guaranteed Ellipse Fitting with the Sampson Distance, in Computer Vision– ECCV 2012, A. Fitzgibbon, S. Lazebnik, P. Perona, Y. Sato, C. Schmid, Eds. (Springer Berlin Heidelberg, 2012), pp. 87–100. [Google Scholar]
- 37.Joint Committee for Guides in Metrology, International Vocabulary of Metrology—Basic and general concepts and associated terms (VIM) (JCGM, ed. 3, 2012); 10.59161/JCGM200-2012. [DOI]
- 38.ISO, Accuracy (trueness and precision) of measurement methods and results—Part 1: General principles and definitions (ISO, ed. 2, 2023); www.iso.org/obp/ui/#iso:std:iso:5725:-1:ed-2:v1:en.
- 39.Roura A., Gravitational redshift in quantum-clock interferometry. Phys. Rev. X 10, 021014 (2020). [Google Scholar]
- 40.Pumpo F. D., Ufrecht C., Friedrich A., Giese E., Schleich W. P., Unruh W. G., Gravitational Redshift Tests with Atomic Clocks and Atom Interferometers. PRX Quantum 2, 040333 (2021). [Google Scholar]
- 41.Rosi G., D’Amico G., Cacciapuoti L., Sorrentino F., Prevedelli M., Zych M., Brukner Č., Tino G. M., Quantum test of the equivalence principle for atoms in coherent superposition of internal energy states. Nat. Commun. 8, 15529 (2017). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 42.Borregaard J., Pikovski I., Testing quantum theory on curved spacetime with quantum networks. Phys. Rev. Res. 7, 023192 (2025). [Google Scholar]
- 43.C. Fromonteil, D. V. Vasilyev, T. V. Zache, K. Hammerer, A. M. Rey, J. Ye, H. Pichler, P. Zoller, Non-local mass superpositions and optical clock interferometry in atomic ensemble quantum networks. arXiv:2509.19501 [quant-ph] (2025).
- 44.M. Gündoğan, R. Barzel, D. Rätzel, Gravitational time dilation in quantum clock interferometry with entangled multi-photon states and quantum memories. arXiv:2601.02470 [quant-ph] (2026).
- 45.Zych M., Costa F., Pikovski I., Brukner Č., Quantum interferometric visibility as a witness of general relativistic proper time. Nat. Commun. 2, 505 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46.Covey J. P., Pikovski I., Borregaard J., Probing curved spacetime with a distributed atomic processor clock. PRX Quantum 6, 030310 (2025). [Google Scholar]
- 47.Loriani S., Friedrich A., Ufrecht C., Di Pumpo F., Kleinert S., Abend S., Gaaloul N., Meiners C., Schubert C., Tell D., Wodey É., Zych M., Ertmer W., Roura A., Schlippert D., Schleich W. P., Rasel E. M., Giese E., Interference of clocks: A quantum twin paradox. Sci. Adv. 5, eaax8966 (2019). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 48.Margalit Y., Zhou Z., Machluf S., Rohrlich D., Japha Y., Folman R., A self-interfering clock as a “which path” witness. Science 349, 1205–1208 (2015). [DOI] [PubMed] [Google Scholar]
- 49.Yudin V., Taichenachev A., Mass defect effects in atomic clocks. Laser Phys. Lett. 15, 035703 (2018). [Google Scholar]
- 50.Asano T., Giese E., Di Pumpo F., Quantum field theory for multipolar composite bosons with mass defect and relativistic corrections. PRX Quantum 5, 020322 (2024). [Google Scholar]
- 51.Zhou Z., Carrasco S. C., Sanner C., Malinovsky V. S., Folman R., Geometric phase amplification in a clock interferometer for enhanced metrology. Sci. Adv. 11, eadr6893 (2025). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 52.Geiger R., Ménoret V., Stern G., Zahzam N., Cheinet P., Battelier B., Villing A., Moron F., Lours M., Bidel Y., Bresson A., Landragin A., Bouyer P., Detecting inertial effects with airborne matter-wave interferometry. Nat. Commun. 2, 474 (2011). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 53.Abend S., Gebbe M., Gersemann M., Ahlers H., Müntinga H., Giese E., Gaaloul N., Schubert C., Lämmerzahl C., Ertmer W., Schleich W. P., Rasel E. M., Atom-chip fountain gravimeter. Phys. Rev. Lett. 117, 203003 (2016). [DOI] [PubMed] [Google Scholar]
- 54.Pelluet C., Arguel R., Rabault M., Jarlaud V., Métayer C., Barrett B., Bouyer P., Battelier B., Atom interferometry in an Einstein elevator. Nat. Commun. 16, 4812 (2025). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 55.Zheng X., Dolde J., Cambria M. C., Lim H. M., Kolkowitz S., A lab-based test of the gravitational redshift with a miniature clock network. Nat. Commun. 14, 4886 (2023). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 56.Bothwell T., Kennedy C. J., Aeppli A., Kedar D., Robinson J. M., Oelker E., Staron A., Ye J., Resolving the gravitational redshift across a millimetre-scale atomic sample. Nature 602, 420–424 (2022). [DOI] [PubMed] [Google Scholar]
- 57.Struckmann C., Corgier R., Loriani S., Kleinsteinberg G., Gox N., Giese E., Métris G., Gaaloul N., Wolf P., Platform and environment requirements of a satellite quantum test of the weak equivalence principle at the 10−17 level. Phys. Rev. D 109, 064010 (2024). [Google Scholar]
- 58.Müller H., Chiow S.-w., Long Q., Herrmann S., Chu S., Atom interferometry with up to 24-photon-momentum-transfer beam splitters. Phys. Rev. Lett. 100, 180405 (2008). [DOI] [PubMed] [Google Scholar]
- 59.Kovachy T., Asenbaum P., Overstreet C., Donnelly C. A., Dickerson S. M., Sugarbaker A., Hogan J. M., Kasevich M. A., Quantum superposition at the half-metre scale. Nature 528, 530–533 (2015). [DOI] [PubMed] [Google Scholar]
- 60.d'Armagnac de Castanet Q., Cognets C. D., Arguel R., Templier S., Jarlaud V., Ménoret V., Desruelle B., Bouyer P., Battelier B., Atom interferometry at arbitrary orientations and rotation rates. Nat. Commun. 15, 6406 (2024). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 61.Hartmann S., Jenewein J., Giese E., Abend S., Roura A., Rasel E. M., Schleich W. P., Regimes of atomic diffraction: Raman versus Bragg diffraction in retroreflective geometries. Phys. Rev. A 101, 053610 (2020). [Google Scholar]
- 62.Lauber T., Küber J., Wille O., Birkl G., Optimized Bose-Einstein-condensate production in a dipole trap based on a 1070-nm multifrequency laser: Influence of enhanced two-body loss on the evaporation process. Phys. Rev. A 84, 043641 (2011). [Google Scholar]
- 63.Pfeiffer D., Dietrich M., Schach P., Birkl G., Giese E., Dichroic mirror pulses for optimized higher-order atomic Bragg diffraction. Phys. Rev. Res. 7, L012028 (2025). [Google Scholar]
- 64.Blackman R. B., Tukey J. W., The measurement of power spectra from the point of view of communications engineering—Part I. Bell Syst. Tech. J. 37, 185–282 (1958). [Google Scholar]
- 65.E.Weisstein, Blackman Function, MathWorld–A Wolfram Resource (Wolfram Research Inc); https://mathworld.wolfram.com/BlackmanFunction.html.
- 66.Chiow S.-w., Kovachy T., Chien H.-C., Kasevich M. A., 102ℏk large area atom interferometers. Phys. Rev. Lett. 107, 130403 (2011). [DOI] [PubMed] [Google Scholar]
- 67.Berrada T., van Frank S., Bücker R., Schumm T., Schaff J.-F., Schmiedmayer J., Integrated Mach–Zehnder interferometer for Bose–Einstein condensates. Nat. Commun. 4, 2077 (2013). [DOI] [PubMed] [Google Scholar]
- 68.Bertoldi A., Minardi F., Prevedelli M., Phase shift in atom interferometers: Corrections for nonquadratic potentials and finite-duration laser pulses. Phys. Rev. A 99, 033619 (2019). [Google Scholar]
- 69.W. Gerlach, O. Stern, Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld, in Walther Gerlach (1889–1979): Eine Auswahl aus seinen Schriften und Briefen, H.-R. Bachmann, H. Rechenberg, Eds. (Springer Berlin Heidelberg, Berlin, Heidelberg, 1989) pp. 26–29. [Experimental Evidence for Space Quantisation in a Magnetic Field]. [Google Scholar]
- 70.M. Bauer, The Stern-Gerlach Experiment, Translation of: “Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld”. arXiv:2301.11343 [physics.hist-ph] (2023). [Experimental Evidence for Space Quantisation in a Magnetic Field].
- 71.B. Efron, R. J. Tibshirani, An introduction to the bootstrap (Chapman and Hall/CRC, 1994). [Google Scholar]
- 72.Efron B., The bootstrap and modern statistics. J. Am. Stat. Assoc. 95, 1293–1296 (2000). [Google Scholar]
- 73.Zoubir A. M., Boashash B., The bootstrap and its application in signal processing. IEEE Signal Process. Mag. 15, 56–76 (1998). [Google Scholar]
- 74.Roura A., Zeller W., Schleich W. P., Overcoming loss of contrast in atom interferometry due to gravity gradients. New J. Phys. 16, 123012 (2014). [Google Scholar]
- 75.Turpin A., Polo J., Loiko Y. V., Küber J., Schmaltz F., Kalkandjiev T. K., Ahufinger V., Birkl G., Mompart J., Blue-detuned optical ring trap for Bose-Einstein condensates based on conical refraction. Opt. Express 23, 1638–1650 (2015). [DOI] [PubMed] [Google Scholar]
- 76.Rosi G., Cacciapuoti L., Sorrentino F., Menchetti M., Prevedelli M., Tino G. M., Measurement of the gravity-field curvature by atom interferometry. Phys. Rev. Lett. 114, 013001 (2015). [DOI] [PubMed] [Google Scholar]
- 77.X. Jiang, D.-C. Cheng, Fitting of 3D circles and ellipses using a parameter decomposition approach, in Fifth International Conference on 3-D Digital Imaging and Model ing (3DIM’05) (IEEE, 2005), pp. 103–109; 10.1109/3DIM.2005.46. [DOI] [Google Scholar]
- 78.Chiow S.-w., Herrmann S., Chu S., Müller H., Noise-immune conjugate large-area atom interferometers. Phys. Rev. Lett. 103, 050402 (2009). [DOI] [PubMed] [Google Scholar]
- 79.R. Halíř, J. Flusser, Numerically stable direct least squares fitting of ellipses, in Proceedings of 6th International Conference in Central Europe on Computer Graphics and Visualization (WSCG) (UNION Agency, 1998) vol. 98, pp. 125–132. [Google Scholar]
- 80.C. Hill, Ellipse fitting algorithm (scipython.com, 2021); https://scipython.com/blog/direct-linear-least-squares-fitting-of-an-ellipse/.
- 81.Ridley K., Rodgers A., An investigation of errors in ellipse-fitting for cold-atom interferometers. EPJ Quantum Technol. 11, 79 (2024). [Google Scholar]
- 82.Gander W., Golub G. H., Strebel R., Least-squares fitting of circles and ellipses. BIT Numer. Math. 34, 558–578 (1994). [Google Scholar]
- 83.Ahn S. J., Rauh W., Warnecke H.-J., Least-squares orthogonal distances fitting of circle, sphere, ellipse, hyperbola, and parabola. Pattern Recognit. 34, 2283–2303 (2001). [Google Scholar]
- 84.Corgier R., Malitesta M., Sidorenkov L. A., Pereira Dos Santos F., Rosi G., Tino G. M., Smerzi A., Salvi L., Pezzè L., Optimized squeezing for accurate differential sensing under large phase noise. Quantum Sci. Technol. 10, 045016 (2025). [Google Scholar]
- 85.Chen X., Zhong J., Song H., Zhu L., Wang J., Zhan M., Proportional-scanning-phase method to suppress the vibrational noise in nonisotope dual-atom-interferometer-based weak-equivalence-principle-test experiments. Phys. Rev. A 90, 023609 (2014). [Google Scholar]
- 86.S. Otabe, N. Kaku, T. Sato, M. Miranda, T. Kawasaki, M. Kozuma, Sensitivity enhancement in atom-interferometer gyroscopes via phase-modulation signal readout scheme. arXiv:2506.23250 [physics.atom-ph] (2025).
- 87.Templier S., Cheiney P., d’Armagnac de Castanet Q., Gouraud B., Porte H., Napolitano F., Bouyer P., Battelier B., Barrett B., Tracking the vector acceleration with a hybrid quantum accelerometer triad. Sci. Adv. 8, eadd3854 (2022). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 88.Chiow S.-w., Williams J., Yu N., Noise reduction in differential phase extraction of dual atom interferometers using an active servo loop. Phys. Rev. A 93, 013602 (2016). [Google Scholar]
- 89.L. Pezzè, A. Santoni, C. Mazzinghi, M. Fattori, A. Smerzi, Joint estimation of phase and uncorrelated dephasing in a differential quantum interferometer. arXiv:2503.18166 [quant-ph] (2025).
- 90.Stockton J. K., Wu X., Kasevich M. A., Bayesian estimation of differential interferometer phase. Phys. Rev. A 76, 033613 (2007). [Google Scholar]
- 91.D. Pfeiffer, “Novel techniques for atom trapping and large-momentum-transfer atom interferometry,” thesis, Technische Universität Darmstadt (2025); 10.26083/tuprints-00031145. [DOI] [Google Scholar]
- 92.W. Ketterle, D. S. Durfee, D. M. Stamper-Kurn, Making, probing and understanding Bose-Einstein condensates. arXiv:cond-mat/9904034 (1999).
- 93.Antoine C., Matter wave beam splitters in gravito-inertial and trapping potentials: Generalized ttt scheme for atom interferometry. Appl. Phys. B 84, 585–597 (2006). [Google Scholar]
- 94.Li X., Shao C.-G., Hu Z.-K., Raman pulse duration effect in high-precision atom interferometry gravimeters. J. Opt. Soc. Am. B 32, 248–257 (2015). [Google Scholar]
- 95.Bott A., Di Pumpo F., Giese E., Atomic diffraction from single-photon transitions in gravity and Standard-Model extensions. AVS Quantum Sci. 5, 044402 (2023). [Google Scholar]
- 96.E. Weisstein, Harmonic addition theorem (MathWorld–A Wolfram Resource); https://mathworld.wolfram.com/HarmonicAdditionTheorem.html.
- 97.Shimazaki H., Shinomoto S., A Method for Selecting the Bin Size of a Time Histogram. Neural Comput. 19, 1503–1527 (2007). [DOI] [PubMed] [Google Scholar]
- 98.H. O. Lohaka, “Making a Grouped-data frequency table: Development and examination of the iteration algorithm,” thesis, Ohio University (2007); https://etd.ohiolink.edu/acprod/odb_etd/ws/send_file/send?accession=ohiou1194981215. [Google Scholar]
- 99.R. Chattamvelli, R. Shanmugam, Arcsine distribution, in Continuous Distributions in Engineering and the Applied Sciences—Part I (Springer, 2021), pp. 57–68; 10.1007/978-3-031-02430-6_5. [DOI] [Google Scholar]
- 100.Virtanen P., Gommers R., Oliphant T. E., Haberland M., Reddy T., Cournapeau D., Burovski E., Peterson P., Weckesser W., Bright J., van der Walt S. J., Brett M., Wilson J., Millman K. J., Mayorov N., Nelson A. R. J., Jones E., Kern R., Larson E., Carey C. J., Polat İ., Feng Y., Moore E. W., Plas J. V., Laxalde D., Perktold J., Cimrman R., Henriksen I., Quintero E. A., Harris C. R., Archibald A. M., Ribeiro A. H., Pedregosa F., van Mulbregt P., SciPy 1.0 Contributors , SciPy 1.0: Fundamental algorithms for scientific computing in Python. Nat. Methods 17, 261–272 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 101.Efron B., Tibshirani R., Bootstrap methods for standard errors, confidence intervals, and other measures of statistical accuracy. Statist. Sci. 1, 54–75 (1986). [Google Scholar]
- 102.Harris C. R., Millman K. J., van der Walt S. J., Gommers R., Virtanen P., Cournapeau D., Wieser E., Taylor J., Berg S., Smith N. J., Kern R., Picus M., Hoyer S., van Kerkwijk M. H., Brett M., Haldane A., Fernández del Río J., Wiebe M., Peterson P., Gérard-Marchant P., Sheppard K., Reddy T., Weckesser W., Abbasi H., Gohlke C., Oliphant T. E., Array programming with NumPy. Nature 585, 357–362 (2020). [DOI] [PMC free article] [PubMed] [Google Scholar]
- 103.Python Software Foundation, Python Language Reference, version 3.12 (Python, 2026); https://docs.python.org/3/reference/.
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Sections S1 to S5
Figs. S1 to S8
Data Availability Statement
All data and code needed to evaluate and reproduce the results in the paper are present in the paper, the Supplementary Materials, and a publicly accessible online repository at www.doi.org/10.5281/zenodo.21340342 based on https://github.com/TU-Darmstadt-APQ/PEAC.git. This study did not generate new materials.