Abstract
This prospective study of 80 patients compared the results of liver scintiscan, ultrasound, and CT scan to the objective findings recorded at laparotomy. Analysis of these data revealed no significant differences in sensitivity, specificity, or accuracy among these three imaging procedures, although a trend toward increased accuracy of the CT scan was noted. In a composite analysis, the accuracy was not improved by combining two or all three of these examinations. A lesion by lesion analysis revealed the inability of any of the three currently used techniques to accurately detect lesions less than 3 cm in diameter.
Full text
PDF





Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Castagna J., Benfield J. R., Yamada H., Johnson D. E. The reliability of liver scans and function tests in detecting metastases. Surg Gynecol Obstet. 1972 Mar;134(3):463–466. [PubMed] [Google Scholar]
- Cedermark B. J., Schultz S. S., Bakshi S., Parthasarathy K. L., Mittelman A., Evans J. T. The value of liver scan in the follow-up study of patients with adenocarcinoma of the colon and rectum. Surg Gynecol Obstet. 1977 May;144(5):745–748. [PubMed] [Google Scholar]
- Drum D. E., Beard J. M. Scintigraphic criteria for hepatic metastases from cancer of the colon and breast. J Nucl Med. 1976 Aug;17(8):677–680. [PubMed] [Google Scholar]
- Ferrucci J. T., Jr Body ultrasonography (second of two parts). N Engl J Med. 1979 Mar 15;300(11):590–602. doi: 10.1056/NEJM197903153001104. [DOI] [PubMed] [Google Scholar]
- HOGG L., Jr, PACK G. T. Diagnostic accuracy of hepatic metastases at laparotomy. AMA Arch Surg. 1956 Feb;72(2):251–252. doi: 10.1001/archsurg.1956.01270200067012. [DOI] [PubMed] [Google Scholar]
- Kilgore E. S., 3rd, Calabretta A. M., Weidner W. A., Graham W. P. The accuracy of liver scanning in the detection of metastatic disease. J Surg Oncol. 1975;7(5):351–354. doi: 10.1002/jso.2930070505. [DOI] [PubMed] [Google Scholar]
- Lamarque J. L., Bruel J. M., Dondelinger R., Vendrell B., Pelissier O., Rouanet J. P., Michel J. L., Boulet P. The use of iodolipids in hepatosplenic computed tomography. J Comput Assist Tomogr. 1979 Feb;3(1):21–24. doi: 10.1097/00004728-197902000-00004. [DOI] [PubMed] [Google Scholar]
- McNeil B. J., Adelstein S. J. Determining the value of diagnostic and screening tests. J Nucl Med. 1976 Jun;17(6):439–448. [PubMed] [Google Scholar]
- Rosenthal S., Kaufman S. The liver scan in metastatic disease. Arch Surg. 1973 May;106(5):656–659. doi: 10.1001/archsurg.1973.01350170028007. [DOI] [PubMed] [Google Scholar]
- Ruiter D. J., Byck W., Pauwels E. K., Taconis W. K., Spaander P. J. Correlation of scintigraphy with short interval autopsy in malignant focal liver disease: a study of 59 cases. Cancer. 1977 Jan;39(1):172–177. doi: 10.1002/1097-0142(197701)39:1<172::aid-cncr2820390128>3.0.co;2-v. [DOI] [PubMed] [Google Scholar]
- Scherer U., Büll U., Rothe R., Eisenburg J., Schildberg F. W., Meister P., Lissner J. Computerized tomography and nuclear imaging of the liver: a comparative study in 83 cases. Eur J Nucl Med. 1978 Apr 1;3(2):71–80. doi: 10.1007/BF00251627. [DOI] [PubMed] [Google Scholar]
- Scherer U., Rothe R., Eisenburg J., Schildberg F., Meister P., Lissner J. Diagnostic accuracy of CT in circumscript liver disease. AJR Am J Roentgenol. 1978 Apr;130(4):711–714. doi: 10.2214/ajr.130.4.711. [DOI] [PubMed] [Google Scholar]
- Snow J. H., Jr, Goldstein H. M., Wallace S. Comparison of scintigraphy, sonography, and computed tomography in the evaluation of hepatic neoplasms. AJR Am J Roentgenol. 1979 Jun;132(6):915–918. doi: 10.2214/ajr.132.6.915. [DOI] [PubMed] [Google Scholar]
- Sullivan D. C., Taylor K. J., Gottschalk A. The use of ultrasound to enhance the diagnostic utility of the equivocal liver scintigraph. Radiology. 1978 Sep;128(3):727–732. doi: 10.1148/128.3.727. [DOI] [PubMed] [Google Scholar]
- Taylor K. J., Carpenter D. A., Hill C. R., McCready V. R. Gray scale ultrasound imaging. The anatomy and pathology of the liver. Radiology. 1976 May;119(2):415–423. doi: 10.1148/119.2.415. [DOI] [PubMed] [Google Scholar]
- Vermess M., Chatterji D. C., Doppman J. L., Grimes G., Adamson R. H. Development and experimental evaluation of a contrast medium for computed tomographic examination of the liver and spleen. J Comput Assist Tomogr. 1979 Feb;3(1):25–31. doi: 10.1097/00004728-197902000-00005. [DOI] [PubMed] [Google Scholar]