Skip to main content
Annals of Surgery logoLink to Annals of Surgery
. 1983 May;197(5):515–519. doi: 10.1097/00000658-198305000-00003

Response of extravascular lung water to intraoperative fluids.

G T Shires 3rd, A B Peitzman, S A Albert, H Illner, M F Silane, M O Perry, G T Shires
PMCID: PMC1353021  PMID: 6847271

Abstract

The effect of Ringer's Lactate (RL) and a colloid containing salt solution Plasmanate (PL) on extravascular lung water (EVLW) during aortic surgery was evaluated in a prospective study of 18 patients. Measured blood loss was replaced with packed red blood cells. In addition to red blood cell replacement, either RL or PL was infused (1) to maintain the cardiac output (CO) equal to or greater than the preoperative value, (2) to maintain the pulmonary capillary wedge pressure (PCWP) plus or minus 2 mmHg of preoperative values, and (3) to keep the urinary output greater than or equal to 30 cc/hr. Cardiac output, EVLW, PCWP, serum colloid osmotic pressure (COP), and intrapulmonary shunt fraction (Qs/Qt) were measured serially. All baseline values were similar between groups. The groups were well matched for age, associated disease, operating time, blood loss, and blood transfusions. During operation, the RL group required two times the rate of infusion of the PL group. Urine flow rates were similar on the day of surgery, but by postoperative days one and two, the PL group had approximately one-half of the urine flow rate compared to the RL group. Cardiac output and Qs/Qt increased in both groups. EVLW did not change after operation in either group, despite marked decrease in COP in the RL group. These data indicate that crystalloid resuscitation to physiologic endpoints does not increase extravascular lung water. Thus, manipulation of COP by PL was unnecessary in these patients.

Full text

PDF
515

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Boutros A. R., Ruess R., Olson L., Hoyt J. L., Baker W. H. Comparison of hemodynamic, pulmonary, and renal effects of use of three types of fluids after major surgical procedures on the abdominal aorta. Crit Care Med. 1979 Jan;7(1):9–13. doi: 10.1097/00003246-197901000-00003. [DOI] [PubMed] [Google Scholar]
  2. Carrico C. J., Canizaro P. C., Shires G. T. Fluid resuscitation following injury: rationale for the use of balanced salt solutions. Crit Care Med. 1976 Mar-Apr;4(2):46–54. [PubMed] [Google Scholar]
  3. Civetta J. M. A new look at the Starling equation. Crit Care Med. 1979 Mar;7(3):84–91. doi: 10.1097/00003246-197903000-00002. [DOI] [PubMed] [Google Scholar]
  4. Demling R. H. Correlation of changes in body weight and pulmonary vascular pressures with lung water accumulation during fluid overload. Crit Care Med. 1979 Apr;7(4):153–156. doi: 10.1097/00003246-197904000-00002. [DOI] [PubMed] [Google Scholar]
  5. Lewis F. R., Jr, Elings V. I. Microprocessor determination of lung water using thermal-green dye double indicator dilution. Surg Forum. 1978;29:182–184. [PubMed] [Google Scholar]
  6. Luz da P. L., Shubin H., Weil M. H., Jacobson E., Stein L. Pulmonary edema related to changes in colloid osmotic and pulmonary artery wedge pressure in patients after acute myocardial infarction. Circulation. 1975 Feb;51(2):350–357. doi: 10.1161/01.cir.51.2.350. [DOI] [PubMed] [Google Scholar]
  7. Peitzman A. B., Shires G. T., 3rd, Corbett W. A., Curreri P. W., Shires G. T. Measurement of lung water in inhalation injury. Surgery. 1981 Aug;90(2):305–312. [PubMed] [Google Scholar]
  8. Peitzman A. B., Shires G. T., 3rd, Illner H., Shires G. T. Pulmonary acid injury: effects of positive end-expiratory pressure and crystalloid vs colloid fluid resuscitation. Arch Surg. 1982 May;117(5):662–668. doi: 10.1001/archsurg.1982.01380290108019. [DOI] [PubMed] [Google Scholar]
  9. Schloerb P. R., Hunt P. T., Plummer J. A., Cage G. K. Pulmonary edema after replacement of blood loss by electrolyte solutions. Surg Gynecol Obstet. 1972 Dec;135(6):893–896. [PubMed] [Google Scholar]
  10. Skillman J. J., Restall D. S., Salzman E. W. Randomized trial of albumin vs. electrolyte solutions during abdominal aortic operations. Surgery. 1975 Sep;78(3):291–303. [PubMed] [Google Scholar]
  11. Thompson J. E., Vollman R. W., Austin D. J., Kartchner M. M. Prevention of hypotensive and renal complications of aortic surgery using balanced salt solution: thirteen-year experience with 670 cases. Ann Surg. 1968 May;167(5):767–778. doi: 10.1097/00000658-196805000-00015. [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Virgilio R. W., Rice C. L., Smith D. E., James D. R., Zarins C. K., Hobelmann C. F., Peters R. M. Crystalloid vs. colloid resuscitation: is one better? A randomized clinical study. Surgery. 1979 Feb;85(2):129–139. [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins

RESOURCES