Skip to main content
Annals of Surgery logoLink to Annals of Surgery
. 1983 May;197(5):536–541. doi: 10.1097/00000658-198305000-00006

Intraoperative autotransfusion. Experience in 725 consecutive cases.

M M Keeling, L A Gray Jr, M A Brink, V K Hillerich, K I Bland
PMCID: PMC1353027  PMID: 6405702

Abstract

Autologous intraoperative transfusion employing the Haemonetics Cell Saver is reported in 725 patients from a general hospital population, of which 75% were cardiovascular patients. The remaining cases included various orthopedic procedures, splenectomy, craniotomy, ectopic pregnancies, Caesarian sections, and exploratory laparotomy. On occasion, this method was utilized in trauma and in pediatric surgery. The product of washed red blood cells gave an average yield of 573 cc per case with an average hematocrit of 55 cc/dl available for autologous infusion. In 100 consecutive open heart procedures operated prior to the Cell Saver period, an average of 1.97 units of bank blood was utilized during operation, as compared with 0.75 units in 100 consecutive cases studied employing the Cell Saver (p less than 0.0001). Homologous blood utilization during cardiac surgery declined more than 50% with the use of the Cell Saver. Quality control was monitored scrupulously and included special precautions against air embolism, abnormal coagulation, and sepsis. The overall mortality rate was 2.8%, and in no instance was mortality or morbidity ascribable to the autologous transfusion. Numerous advantages offered by autotransfusion include prevention of sensitization of the recipient to various antigens in donor erythrocytes, leucocytes, platelets, and plasma, and avoidance of transfusion-transmitted diseases, especially viral hepatitis. Additionally, autologous blood, the only perfectly compatible product, provided immediate availability while conserving blood bank resources. In circumstances in which the intraoperative blood loss exceeded 1000 cc in the adult, its use was observed to be cost-effective. In the present study, autotransfusion proved safe, efficient, and in some instances life saving.

Full text

PDF
536

Selected References

These references are in PubMed. This may not be the complete list of references from this article.

  1. Bell W. The hematology of autotransfusion. Surgery. 1978 Nov;84(5):695–699. [PubMed] [Google Scholar]
  2. Brewster D. C., Ambrosino J. J., Darling R. C., Davison J. K., Warnock D. F., May A. R., Abbott W. M. Intraoperative autotransfusion in major vascular surgery. Am J Surg. 1979 Apr;137(4):507–513. doi: 10.1016/0002-9610(79)90122-3. [DOI] [PubMed] [Google Scholar]
  3. Cain J. L. Autologous transfusions in elderly total joint replacement patients. A review of blood replacement methods. J Fla Med Assoc. 1979 Jan;66(1):35–38. [PubMed] [Google Scholar]
  4. Greenhalgh R. M., Kirk C. J., Bartoll A., Owen J., Mitchell T. R., Gerken A., Master B., Gregory I. C. Intraoperative autotransfusion for elective aortic surgery. Br J Surg. 1978 Oct;65(10):685–687. doi: 10.1002/bjs.1800651005. [DOI] [PubMed] [Google Scholar]
  5. Klebanoff G. Intraoperative autotransfusion with the Bentley ATS-100. Surgery. 1978 Nov;84(5):708–712. [PubMed] [Google Scholar]
  6. Kluge R. M., Calia F. M., McLaughlin J. S., Hornick R. B. Sources of contamination in open heart surgery. JAMA. 1974 Dec 4;230(10):1415–1418. [PubMed] [Google Scholar]
  7. Lilleaasen P., Frøysaker T. Fresh autologous blood in open-heart surgery. Influence on blood requirements, bleeding and platelet counts. Scand J Thorac Cardiovasc Surg. 1979;13(1):41–46. doi: 10.3109/14017437909101785. [DOI] [PubMed] [Google Scholar]
  8. Matsumoto K., Tomita M., Koga Y., Shibata K., Baba H., Uchida N., Iwamoto I. Intra- and postoperative autotransfusion in open heart surgery under simple hypothermia in children. Jpn J Surg. 1980 Mar;10(1):39–47. doi: 10.1007/BF02468645. [DOI] [PubMed] [Google Scholar]
  9. Mattox K. L. Comparison of techniques of autotransfusion. Surgery. 1978 Nov;84(5):700–702. [PubMed] [Google Scholar]
  10. Merrill B. S., Mitts D. L., Rogers W., Weinberg P. C. Autotransfusion: intraoperative use in ruptured ectopic pregnancy. J Reprod Med. 1980 Jan;24(1):14–16. [PubMed] [Google Scholar]
  11. Mullen S. A. Autologous blood transfusions. J Fla Med Assoc. 1979 Jan;66(1):31–34. [PubMed] [Google Scholar]
  12. Noon G. P. Intraoperative autotransfusion. Surgery. 1978 Nov;84(5):719–721. [PubMed] [Google Scholar]
  13. Orr M. Autotransfusion: the use of washed red cells as an adjunct to component therapy. Surgery. 1978 Nov;84(5):728–732. [PubMed] [Google Scholar]
  14. Parker F. B., Jr, West H. Autotransfusion following open-heart surgery. Ann Thorac Surg. 1978 Dec;26(6):559–562. doi: 10.1016/s0003-4975(10)62942-6. [DOI] [PubMed] [Google Scholar]
  15. Schaff H. V., Hauer J. M., Brawley R. K. Autotransfusion in cardiac surgical patients after operation. Surgery. 1978 Nov;84(5):713–718. [PubMed] [Google Scholar]
  16. Schaff H. V., Hauer J., Gardner T. J., Donahoo J. S., Watkins L., Jr, Gott V. L., Brawley R. K. Routine use of autotransfusion following cardiac surgery: experience in 700 patients. Ann Thorac Surg. 1979 Jun;27(6):493–499. doi: 10.1016/s0003-4975(10)63357-7. [DOI] [PubMed] [Google Scholar]
  17. Sharp W. V., Stark M., Donovan D. L. Modern autotransfusion. Experience with a washed red cell processing technique. Am J Surg. 1981 Oct;142(4):522–524. doi: 10.1016/0002-9610(81)90390-1. [DOI] [PubMed] [Google Scholar]
  18. Warnock D. F., Davison J. K., Brewster D. C., Darling R. C., Abbott W. M. Modification of the Haemonetics Cell Saver for optional high flow rate autotransfusion. Am J Surg. 1982 Jun;143(6):765–768. doi: 10.1016/0002-9610(82)90055-1. [DOI] [PubMed] [Google Scholar]
  19. Young J. N., Ecker R. R., Moretti R. L., Iverson L. I., Ennix C. L., Jr, Etheredge S. N., Webb R. L., Jackson W. S., May R. D., May I. A. Autologous blood retrieval in thoracic, cardiovascular, and orthopedic surgery. Am J Surg. 1982 Jul;144(1):48–52. doi: 10.1016/0002-9610(82)90600-6. [DOI] [PubMed] [Google Scholar]

Articles from Annals of Surgery are provided here courtesy of Lippincott, Williams, and Wilkins

RESOURCES