Abstract
Introduction
To explore the potential of a newly developed subtraction technique in coronary computed tomography angiography (CCTA) for improving image quality and vessel wall visibility without introducing misregistration artifacts.
Methods
Fifty-six patients who underwent CCTA scans using dual-layer detector spectral CT (SDCT) were retrospectively enrolled. Dark-blood images were generated by subtracting virtual non-contrast (VNC) datasets from 70-keV datasets. Qualitative evaluation of dark-blood images included assessments of image quality, inner-wall visualization, and outer-wall visualization. Quantitative parameters were compared between conventional CCTA images and dark-blood images. The quantitative assessment involved evaluating contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). SNRwall, SNRlumen, SNRperiaortic fat, CNRwall-lumen, and CNRwall-periaortic fat were calculated. Two experienced radiologists independently evaluated the images, and inter-rater variability was assessed.
Results
Patients were categorized into three groups based on plaque types: Group A (calcified plaques, n=88), Group B (non-calcified plaques, n=15), and Group C (vessels without plaque, n=56). Dark-blood images of non-calcified plaques and vessels without plaque exhibited higher image quality and inner-wall visualization scores compared to calcified plaques (all p < 0.05). The subjective scores of radiologists showed good consistency (all kappa values > 0.7). Compared to conventional images, dark-blood images demonstrated higher quantitative scores in terms of SNRwall, SNRlumen, SNRperiaortic fat, CNRwall-lumen, and CNRwall-periaortic fat (all p < 0.001).
Discussion
The dark-blood technique enabled superior coronary wall assessment without misregistration artifacts, overcoming a key limitation of prior subtraction CCTA. RCA motion artifacts remain a technical challenge that warrants phase-specific protocol optimization in our study.
Conclusion
Dark-blood images derived from SDCT demonstrated improved image quality of coronary arteries without misregistration artifacts and enhanced visualization of the coronary vessel wall.
Keywords: Dual-layer spectral CT, Coronary computed tomography angiography, Subtraction technique, Image quality, Coronary artery disease, Dark-blood images
1. INTRODUCTION
Coronary artery disease (CAD) has been established as the leading cause of death worldwide [1]. Coronary computed tomography angiography (CCTA) plays a pivotal role in the screening, decision-making, and treatment planning of CAD due to its noninvasive nature [2]. However, the interpretation of CCTA may be limited by severe calcified plaques or implanted stents, which induce blooming artifacts, beam-hardening effects, and partial volume averaging due to high intravascular contrast concentrations. These artifacts can impair the image quality of conventional CCTA and lead to an overestimation of stenosis [3]. Additionally, traditional bright-blood images have limitations in visualizing the vessel wall due to low contrast between the arterial wall and the lumen.
Subtraction CCTA was introduced a few years ago as a novel post-processing technique. However, a two-breath-hold subtraction method, which subtracts non-contrast images from contrast-enhanced images, can produce misregistration artifacts [4]. These artifacts have limited the development of subtraction technology. Using a dual-layer spectral detector CT (SDCT), dark-blood images can be generated without misregistration artifacts, because virtual non-contrast (VNC) and virtual monoenergetic images (VMI) are derived from the same dataset in the same cardiac phase.
SDCT uses a single X-ray source paired with a dual-layer detector system that enables spectral separation at the detector level. During image acquisition, the two detector layers simultaneously capture different X-ray absorption profiles, with the low-energy spectrum in the upper layer and high-energy photons in the deeper layer. By linearly combining these signals based on photoelectric and Compton effects, VNC and VMI datasets can be generated [5]. The system provides a range of energy levels from 40 to 200 kilo-electron-volts (keV) [6]. The 70-keV image, which closely approximates a conventional CT image, offers optimal image quality [7, 8], while the VNC image provides diagnostic confidence equivalent to a true non-contrast image [9]. In this study, dark-blood images were generated by subtracting VNC datasets from 70-keV datasets, ensuring complete spatial and temporal alignment. This approach suppressed the contrast agent in the vascular lumen, thereby enhancing lumen-to-wall contrast and facilitating vessel wall evaluation [10].
2. In previous studies, researchers primarily focused on subtracting calcified plaques and stents, often neglecting non-calcified plaques. This study aims to investigate whether a newly developed subtraction technique can enhance coronary vessel wall visualization across various plaque types without causing misregistration, potentially providing insights for the clinical application of subtraction methods.
2. MATERIALS AND METHODS
2.1. Patient Population
This study was conducted in accordance with the Declaration of Helsinki. The ethics committee of the Affiliated Changshu Hospital of Nantong University approved this single-center retrospective study (CSEY2021115), and the requirement for written informed consent was waived. We included 64 consecutive patients who underwent clinically indicated CCTA using SDCT between February 2021 and October 2022. Patients with implanted stents (n = 3) or those exhibiting motion or pulsation artifacts (n = 5) were excluded. A prospective power analysis (α = 0.05, β = 0.2, effect size = 0.8) indicated a minimum requirement of 51 patients. Ultimately, 56 patients were evaluated. The flowchart of patient enrollment is shown in Fig. (1).
Fig. (1).

Flowchart of patient enrollment.
2.2. Scan Protocol
CCTA was performed using a 64-slice single-source SDCT (IQon, Philips Healthcare). Patients without contraindications and with a heart rate >75 bpm were administered a cardioselective beta-blocker (metoprolol 50 mg) 1 hour prior to scanning. Scans were performed during an inspiratory breath-hold with retrospective electrocardiogram gating in the cranial-caudal direction, covering the entire heart from the carina to the diaphragm. A contrast-enhanced scan was acquired following a non-contrast scan. Iodinated contrast medium (Iopamidol-370, Bayer Schering Pharma) was administered at 1.0–1.2 mL/kg at a rate of 3.5–4.5 mL/s, followed by 30 mL of physiological saline injected at the same rate. An automatic bolus-tracking technique with a trigger threshold of 120–150 Hounsfield units (HU) in the ascending aorta was employed. Scanning parameters were as follows: tube voltage, 120 kVp; tube current, automatically adjusted; collimation, 64 × 0.625 mm; pitch, 0.2; rotation time, 0.27 s; field of view, 220 mm; image matrix, 512 × 512; slice thickness, 0.67 mm; and slice increment, 0.34 mm.
2.3. Radiation Dose
The volume of CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy × cm) were automatically recorded post-scanning. The effective radiation dose (ED) was calculated using the formula ED = DLP × 0.014 mSv × mGy−1 × cm−1 [11].
2.4. Image Reconstruction and Post-Processing
Images were reconstructed and processed on a post-processing workstation (iDose4, IntelliSpace Portal version 9.0, Philips Healthcare). From a single spectral dataset covering the same range in the same cardiac phase, 70-keV and VNC images were extracted. Dark-blood images were then generated by subtracting the VNC datasets from the 70-keV datasets (Fig. 2a–l), effectively removing the contrast agent from the vessel lumen.
Fig. (2a-l).

Comparison of different types of plaque between conventional images and dark-blood images. Dark-blood images were generated by subtracting VNC datasets from 70-keV datasets. Vessel without plaque in LAD (a-d) clearly delineates the inner and outer vessel wall in dark-blood image. The presence of non-calcified plaques in RCA (e-h) and a calcified plaque in LAD (i-l) was observed. Compared with conventional images, both calcified and non-calcified plaques can improve the visualization of the vessel wall in dark-blood images.
2.5. Image Analysis
Segments with a diameter of 1.5 mm or greater were assessed, including the right coronary artery (RCA), left anterior descending artery (LAD), and left circumflex artery (LCX). Plaques were classified as calcified if HU was greater than 350 HU or non-calcified if HU was less than 350 HU.
Conventional and dark-blood images were evaluated blindly by two radiologists with 5 years (XY.C) and 10 years (XL.L) of experience in cardiovascular radiology. Qualitative image analysis of dark-blood images, including image quality, inner-wall visualization, and outer-wall visualization, was independently rated by both radiologists. These characteristics were scored using a 5-point Likert scale. A score of 1 indicated poor image quality with severe noise and artifacts, 2 indicated weak image quality with high noise and minimal artifacts, 3 indicated fair image quality with moderate noise and mild artifacts, 4 indicated good image quality with slight noise, and 5 indicated excellent image quality with sharp edges and no artifacts.
Quantitative image analysis included measurements of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The mean CT value and standard deviation (SD) were measured three times within a region of interest (ROI) and averaged. ROIs were drawn on the vessel lumen, vessel wall, and periaortic fat near the plaque in the three coronary branches (RCA, LAD, and LCX). For vessels without plaques, ROIs were drawn in the same manner. ROIs were circular with an area of 0.4 mm2 and carefully positioned to avoid adjacent tissue and plaque. The size and location of the ROIs were kept consistent across both datasets using copy and paste commands.
SNRwall, SNRlumen, SNRperiaortic fat, CNR between the vessel wall and lumen (CNRwall-lumen), and between the wall and the periaortic fat (CNRwall-periaortic fat) were calculated using the following formula:
where the subscript “tissue” refers to mean ROI values in the vessel lumen and periaortic fat, respectively.
3. STATISTICAL ANALYSIS
Satistical analyses were performed using SPSS statistical software (Version 26.0, IBM, USA). Continuous data were assessed for normality using the Kolmogorov-Smirnov test. Parameters are presented as mean ± standard deviation (SD) for normally distributed data or as counts with percentages for categorical data. For multiple comparisons, paired sample t-tests with Bonferroni correction were applied. Inter-observer agreement for subjective image quality was evaluated using Kappa statistics, with values greater than 0.75 considered excellent, between 0.40 and 0.75 considered fair to good, and less than 0.40 considered poor. The Friedman test was used to compare quantitative parameters between calcified and non-calcified plaques in dark-blood images. A p-value of less than 0.05 was considered statistically significant.
4. RESULTS
4.1. Participants and Radiation Dose
A total of 56 patients (mean age 65.2 ± 11.4 years, range 36-86 years, 64.3% male) were enrolled. Nine vessels were excluded: six due to motion or pulsation artifacts, three due to diameters less than 1.5 mm, and one due to absence. Finally, 159 vessels [RCA (n=50), LAD (n=56), and LCX (n=53)] were included in the analysis. The vessels were divided into three groups based on plaque type: Group A (calcified plaque, n=88), Group B (non-calcified plaque, n=15), and Group C (vessels without plaque, n=56). Patient characteristics are listed in Table 1. The CTDIvol, DLP, and ED were 45.97 ± 1.98 mGy, 798.96 ± 72.82 mGy × cm, and 11.19 ± 1.02 mSv, respectively.
Table 1.
Patient characteristics. Data are expressed as mean ± standard deviation or counts (percentage).
| Characteristics | Value |
|---|---|
| Patient demographics (n = 56) | |
| Age (years) | 65.2 ± 11.4 |
| Male | 36 (64.3%) |
| Body mass index (kg/m2) | 24.1 ± 3.1 |
| Hypertension | 44 (78.6%) |
| Hyperlipidemia | 21 (37.5%) |
| Diabetes | 18 (32.1%) |
| Plaque characteristics (n =103) | |
| Calcified | 88 (83.8%) |
| Non-Calcified | 15 (14.3%) |
4.2. Qualitative Evaluation of Image Quality of Dark-blood Images
Two typical examples of calcified and non-calcified plaques in conventional and dark-blood images are shown in Fig. (2). Dark-blood images provided improved visualization of the vessel wall, whereas conventional images did not allow for observation of the coronary vessel wall and were therefore not scored. Qualitative evaluation included image quality, inner-wall visualization, and outer-wall visualization. The results of the qualitative evaluation scores for different plaque types are presented in Table 2.
Table 2.
Qualitative image quality scores of dark-blood images. Data are mean ± standard deviation. p < 0.05 indicates a statistically significant difference.
| Image quality score | p-value | ||||||
|---|---|---|---|---|---|---|---|
| Parameter and reader | Global segments (n=159) |
Group A
Calcified plaque (n=88) |
Group B
Non-calcified plaque (n=15) |
Group C
Without plaque (n=56) |
A vs. B | A vs. C | B vs. C |
| Image quality | |||||||
| Reader 1 | 4.87±0.39 | 4.81±0.48 | 4.93±0.26 | 4.96±0.19 | 0.033 | <0.001 | 0.305 |
| Reader 2 | 4.87±0.43 | 4.80±0.55 | 5.00±0 | 4.96±0.19 | 0.002 | <0.001 | 0.132 |
| Inner-wall visualization | |||||||
| Reader 1 | 4.91±0.33 | 4.83±0.43 | 4.93±0.26 | 5.00±0 | 0.001 | <0.001 | <0.001 |
| Reader 2 | 4.88±0.41 | 4.80±0.53 | 5.00±0 | 4.98±0.13 | 0.001 | <0.001 | 0.298 |
| Outer-wall visualization | |||||||
| Reader 1 | 4.93±0.34 | 4.89±0.44 | 5.00±0 | 5.00±0 | 0.412 | <0.001 | <0.001 |
| Reader 2 | 4.93±0.36 | 4.89±0.47 | 4.93±0.26 | 5.00±0 | 0.428 | <0.001 | <0.001 |
For all segments, inter-observer agreement was excellent for inner-wall visualization (kappa = 0.76), outer-wall visualization (kappa = 0.72), and overall image quality (kappa = 0.79). Non-calcified plaque images and vessels without plaque had higher qualitative scores for image quality and inner-wall visualization compared to calcified plaque images (all p < 0.05). No significant differences were observed between non-calcified plaque images and vessels without plaque. Regarding outer-wall visualization, vessels without plaque had higher qualitative scores (p < 0.001), with no significant difference between non-calcified and calcified plaque images.
4.3. Quantitative Evaluation of Image Quality
SNRwall, SNRlumen, SNRperiaortic fat, CNRwall-lumen, and CNRwall-periaortic fat were calculated. The detailed results for SNRs and CNRs in conventional and dark-blood images are presented in Table 3. The SNRs and CNRs for global segments, as well as for calcified and non-calcified plaques in dark-blood images, were significantly higher than those in conventional images (all p < 0.05). The exception was the CNRwall-lumen for non-calcified plaques, where the difference was not statistically significant (p = 0.371).
Table 3.
SNRs and CNRs of dark-blood images and conventional images. Data are mean ± standard deviation. P < 0.05 indicates a statistically significant difference.
| Parameter | n | Quantitative values | p-value | |
|---|---|---|---|---|
| Dark-blood images | Conventional images | |||
| SNR vessel wall | ||||
| Global segment | 159 | 174.14±128.16 | 2.91±2.55 | <0.001 |
| Calcified plaque | 88 | 161.92±80.55 | 3.29±3.16 | <0.001 |
| Non-calcified plaque | 15 | 355.02±286.59 | 2.87±2.14 | <0.001 |
| SNR vessel lumen | ||||
| Global segment | 159 | 302.20±225.00 | 34.93±19.96 | <0.001 |
| Calcified plaque | 88 | 281.32±217.73 | 30.84±17.01 | <0.001 |
| Non-calcified plaque | 15 | 215.02±93.01 | 31.66±16.32 | 0.014 |
| SNR periaortic fat | ||||
| Global segment | 159 | 439.34±231.78 | 12.62±7.11 | <0.001 |
| Calcified plaque | 88 | 444.41±258.77 | 12.51±7.47 | <0.001 |
| Non-calcified plaque | 15 | 432.45±159.67 | 11.98±7.66 | <0.001 |
| CNR between the vessel wall and lumen | ||||
| Global segment | 159 | 20.89±11.27 | 10.30±5.91 | <0.001 |
| Calcified plaque | 88 | 20.64±11.57 | 9.51±4.61 | <0.001 |
| Non-calcified plaque | 15 | 26.40±13.41 | 16.73±11.62 | 0.371 |
| CNR between the vessel wall and periaortic fat | ||||
| Global segment | 159 | 7.26±8.93 | 2.10±2.65 | <0.001 |
| Calcified plaque | 88 | 7.24±8.92 | 2.23±3.23 | <0.001 |
| Non-calcified plaque | 15 | 11.85±7.61 | 2.76±1.63 | <0.001 |
Differences between calcified and non-calcified plaques in dark-blood images are illustrated in Fig. (3). SNRwall for non-calcified plaques was significantly higher than that for calcified plaques (p < 0.05). However, the differences in other measurements were not statistically significant (p > 0.05).
Fig. (3).

Bar plots show signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) among calcified and non-calcified plaque in dark-blood images. The SNRwall, SNRlumen, SNRperiaortic fat, CNRwall-lumen, and CNRwall-periaortic fat were respectively analyzed. The ns symbol indicates the value p>0.05. The **** symbol indicates the value p<0.001.
5. DISCUSSION
In our study, we investigated a novel subtraction technique based on SDCT, which improved visualization of the coronary vessel wall by suppressing lumen contrast enhancement. All image subtractions were successfully performed without misregistration artifacts. The quality of dark-blood images was sufficient for assessment, with clear depiction of both the inner and outer vessel walls.
Our results indicated that, in dark-blood images, calcified plaques primarily affected overall image quality and inner-wall visualization. However, outer-wall visualization did not show a statistically significant difference compared to vessels without plaques, regardless of plaque type. Additionally, SNRwall in calcified plaques was significantly lower than in non-calcified plaques, which may be due to the limited number of non-calcified plaques included in the study. Compared with conventional images, dark-blood images significantly increased SNRs and CNRs, particularly for calcified plaques, although no significant difference was observed in SNRwall-lumen for non-calcified plaques (p = 0.371).
Despite advancements in CT technology, accurately evaluating the percent diameter stenosis of coronary arteries remains challenging. Calcified plaques obscure lumen patency due to partial volume effects and beam-hardening artifacts, often leading to an overestimation of stenosis severity [12]. Moreover, diagnostic accuracy improves with physician experience, emphasizing the importance of proficiency in visual assessment techniques [13]. When the coronary vessel wall is clearly visualized, quantitative assessment of stenosis can substantially reduce inter-physician variability, thereby enhancing the reliability of diagnostic conclusions, as confirmed in our previous studies [14]. Similarly, prior research has demonstrated that CE-boost–derived dark-blood imaging improves image quality and plaque visibility in head and neck CTA [15].
The dark-blood sequence in magnetic resonance imaging has the potential to depict abnormalities in vascular walls [16]. CT post-processing techniques can also achieve blood signal suppression, including dual-energy CT material decomposition [9], manual adjustment of CT value distribution [17], and deep learning reconstruction algorithms [18]. Previous studies primarily focused on assessing calcified plaques and stents. In this study, we explored the value of dark-blood imaging for visualizing vascular walls and investigated differences across various plaque types. Furthermore, subtraction techniques have shown promise in eliminating blooming artifacts [19, 20]. Previous research reported misregistration artifacts in approximately half of the target segments [4], which hindered the development of subtraction techniques. This problem may result from differences in breath-hold times between non-contrast and contrast scans. Kidoh et al. developed a technique involving an initial scan at 50 HU attenuation of the ascending aorta followed by a second scan at peak attenuation, which shortened breath-hold time and reduced misregistration artifacts [21]. However, this study included only five patients, and breath-hold times remained longer than in standard scanning protocols. Subtraction using dual-energy CT has also been reported to mitigate mismatching artifacts [22]. In our study, dark-blood images were generated by subtracting virtual non-contrast images from monochromatic images derived from SDCT, captured in the same cardiac phase and image range. This approach enabled iodine subtraction from the lumen while avoiding misregistration artifacts.
In our study, iodine in the lumen was effectively subtracted using the ratio of CT attenuation between VNC and 70-keV images. Xu et al. suggested that 100 keV is the optimal monoenergetic energy level for evaluating calcification [23], which is higher than the 90 keV proposed by Stehli et al. [24]. Lower energy levels generally enhance intraluminal contrast but increase image noise and artifacts, whereas higher energy levels reduce contrast while decreasing noise and artifacts. The optimal keV threshold for diagnosing calcium-induced coronary stenosis remains debated. In our study, the 70-keV image provided image quality comparable to or better than conventional images [25], and was therefore selected for the subtraction process. VNC images were reconstructed using material decomposition algorithms, which effectively separate iodine from soft tissue. Both VNC and 70-keV images were obtained from routine clinical imaging, and because scan parameters were consistent, the radiation dose was equivalent to that of standard clinical CCTA.
This study has several limitations. First, a significant number of right coronary arteries (RCAs) were excluded due to artifacts. Coronary arteries are often best visualized at different phases of the R-R interval (RCA, 40%; LCX, 50%; LAD, 60–70%) [26]. In our study, reconstruction phases were primarily set at 70% of the R-R interval, which was optimal for the LAD but less so for the RCA. Additionally, the RCA’s location along the atrioventricular groove results in greater motion displacement and artifacts caused by atrioventricular motion asynchrony, which may explain the higher frequency of misregistration. Second, the sample size of this single-center study was relatively small, which may introduce selection bias. Third, plaque visibility was not further assessed. Future comparative studies between dark-blood CTA and MRI could provide a more comprehensive evaluation of coronary plaques.
CONCLUSION
Our study demonstrates that the subtraction-based dark-blood CT technique using SDCT, which involves subtracting VNC from monochromatic images, effectively eliminates misregistration artifacts while significantly enhancing the visualization of coronary artery walls. The single-phase acquisition avoids temporal mismatches and motion-related artifacts inherent in conventional dual-phase approaches, markedly improving the technical success rate of dark-blood imaging. By suppressing lumen density, this method enhances vessel wall conspicuity without compromising diagnostic image quality and has the potential to serve as a valuable quantitative tool for evaluating coronary stenosis. The observed differential effects of calcified plaques on dark-blood image quality may have clinical implications for treatment stratification. However, this technical feasibility study was not designed to assess therapeutic outcomes, and further research in larger cohorts is warranted. With additional refinement, dark-blood CTA could emerge as a practical, non-invasive alternative for comprehensive coronary artery evaluation.
ACKNOWLEDGEMENTS
Declared none.
LIST OF ABBREVIATIONS
- CAD
Coronary artery disease
- CCTA
Coronary computed tomography angiography
- SDCT
Dual-layer spectral detector CT
- VNC
Virtual non-contrast
- VMI
Virtual monoenergetic image
- keV
Kilo electron-volt
- CTDIvol
Volume of CT dose index
- DLP
Dose length product
- ED
Effective dose
- LAD
Left anterior descending
- RCA
Right coronary artery
- ROI
Region of interest
- CPR
Curved planar reconstruction
- LCX
Left circumflex artery
- SNR
Signal-to-noise ratio
- CNR
Contrast-to-noise-ratio
- SD
Standard deviation.
USE OF AI TOOLS DECLARATION
The authors declare they have not used Artificial Intelligence (AI) tools in the creation of this article.
AUTHORS’ CONTRIBUTIONS
The authors confirm their contribution to the paper as follows: Z.S.: Study conception and design; W.C.: Data collection; Y.L.: Data analysis or interpretation; C.H., H.U.: Methodology; Y.C.: Investigation; X.L.: Draft manuscript. All authors reviewed the results and approved the final version of the manuscript.
ETHICS APPROVAL AND CONSENT TO PARTICIPATE
The ethics committee of the Affiliated Changshu Hospital of Nantong University, China approved this single-center retrospective study (CSEY2021115), China.
HUMAN AND ANIMAL RIGHTS
All procedures performed in studies involving human participants were in accordance with the ethical standards of institutional and/or research committee and with the 1975 Declaration of Helsinki, as revised in 2013.
CONSENT FOR PUBLICATION
The requirement for written informed consent was waived.
STANDARDS OF REPORTING
STROBE guidelines were followed.
AVAILABILITY OF DATA AND MATERIAL
All the data and supporting information is provided within the article.
FUNDING
This work was supported by the Science and Technology Project for “Star of Medical Imaging” of Suzhou Medical Association (2023YX-Q01), and the Science and Technology Plan Project of Changshu Municipal Health Commission, China (CSWS202308).
CONFLICT OF INTEREST
The authors declare no conflict of interest, financial or otherwise.
REFERENCES
- 1.Malakar A.K., Choudhury D., Halder B., Paul P., Uddin A., Chakraborty S. A review on coronary artery disease, its risk factors, and therapeutics. J Cell Physiol. 2019;234(10):16812–16823. doi: 10.1002/jcp.28350. [DOI] [PubMed] [Google Scholar]
- 2.Lin L., Wang Y., Yi Y., Cao J., Kong L., Qian H., Zhang H., Wu W., Wang Y., Jin Z. Application of the low-dose one-stop-shop cardiac CT protocol with third-generation dual-source CT. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2017;39(1):34–41. doi: 10.3881/j.issn.1000-503X.2017.01.007. [DOI] [PubMed] [Google Scholar]
- 3.Serruys P.W., Hara H., Garg S., Kawashima H., Nørgaard B.L., Dweck M.R., Bax J.J., Knuuti J., Nieman K., Leipsic J.A., Mushtaq S., Andreini D., Onuma Y. Coronary computed tomographic angiography for complete assessment of coronary artery disease. J Am Coll Cardiol. 2021;78(7):713–736. doi: 10.1016/j.jacc.2021.06.019. [DOI] [PubMed] [Google Scholar]
- 4.Fuchs A., Kühl J.T., Chen M.Y., Helqvist S., Razeto M., Arakita K., Steveson C., Arai A.E., Kofoed K.F. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography. J Cardiovasc Comput Tomogr. 2015;9(5):393–398. doi: 10.1016/j.jcct.2015.03.016. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Greffier J., Villani N., Defez D., Dabli D., Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023;104(4):167–177. doi: 10.1016/j.diii.2022.11.003. [DOI] [PubMed] [Google Scholar]
- 6.Kalisz K., Rassouli N., Dhanantwari A., Jordan D., Rajiah P. Noise characteristics of virtual monoenergetic images from a novel detector-based spectral CT scanner. Eur J Radiol. 2018;98:118–125. doi: 10.1016/j.ejrad.2017.11.005. [DOI] [PubMed] [Google Scholar]
- 7.Doerner J., Wybranski C., Byrtus J., Houbois C., Hauger M., Heneweer C., Siedek F., Hickethier T., Große Hokamp N., Maintz D., Haneder S. Intra-individual comparison between abdominal virtual mono-energetic spectral and conventional images using a novel spectral detector CT. PLoS One. 2017;12(8):e0183759. doi: 10.1371/journal.pone.0183759. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.D’Angelo T., Lanzafame L.R.M., Micari A., Blandino A., Yel I., Koch V., Gruenewald L.D., Vogl T.J., Booz C., Bucolo G.M., Cannizzaro M.T., Ascenti G., Mazziotti S. Improved coronary artery visualization using virtual monoenergetic imaging from dual-layer spectral detector CT angiography. Diagnostics. 2023;13(16):2675. doi: 10.3390/diagnostics13162675. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Si-Mohamed S., Dupuis N., Tatard-Leitman V., Rotzinger D., Boccalini S., Dion M., Vlassenbroek A., Coulon P., Yagil Y., Shapira N., Douek P., Boussel L. Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma. Eur Radiol. 2019;29(12):6762–6771. doi: 10.1007/s00330-019-06322-5. [DOI] [PubMed] [Google Scholar]
- 10.Rotzinger D.C., Si-Mohamed S.A., Shapira N., Douek P.C., Meuli R.A., Boussel L. “Dark-blood” dual-energy computed tomography angiography for thoracic aortic wall imaging. Eur Radiol. 2020;30(1):425–431. doi: 10.1007/s00330-019-06336-z. [DOI] [PubMed] [Google Scholar]
- 11.Chu P.W., Kofler C., Haas B., Lee C., Wang Y., Chu C.A., Stewart C., Mahendra M., Delman B.N., Bolch W.E., Smith-Bindman R. Dose length product to effective dose coefficients in adults. Eur Radiol. 2023;34(4):2416–2425. doi: 10.1007/s00330-023-10262-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12.Abdulla J., Pedersen K.S., Budoff M., Kofoed K.F. Influence of coronary calcification on the diagnostic accuracy of 64-slice computed tomography coronary angiography: A systematic review and meta-analysis. Int J Cardiovasc Imaging. 2012;28(4):943–953. doi: 10.1007/s10554-011-9902-6. [DOI] [PubMed] [Google Scholar]
- 13.Giusca S., Schütz M., Kronbach F., Wolf D., Nunninger P., Korosoglou G. Coronary computer tomography angiography in 2021 - Acquisition protocols, tips and tricks and heading beyond the possible. Diagnostics. 2021;11(6):1072. doi: 10.3390/diagnostics11061072. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Li X., Xu Y., Sun Z., Chen W., Chen X., Hu C.H. Accuracy and consistency of subtraction dual-layer spectral computed tomography in diagnosing coronary stenosis: Invasive coronary angiography validation study. Quant Imaging Med Surg. 2025;15(7):6137–6146. doi: 10.21037/qims-24-1810. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15.Li J., Zhang Y., Hou J., Li Y., Zhao Z., Xu M., Liu W. Clinical application of dark-blood imaging in head and neck CT angiography: Effect on image quality and plaque visibility. Acad Radiol. 2024;31(6):2478–2487. doi: 10.1016/j.acra.2023.11.015. [DOI] [PubMed] [Google Scholar]
- 16.Edelman R.R., Leloudas N., Pang J., Koktzoglou I. Dark blood cardiovascular magnetic resonance of the heart, great vessels, and lungs using electrocardiographic-gated three-dimensional unbalanced steady-state free precession. J Cardiovasc Magn Reson. 2021;23(1):127. doi: 10.1186/s12968-021-00808-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17.Rowe S.P., Chu L.C., Recht H.S., Lin C.T., Fishman E.K. Black-blood cinematic rendering: A new method for cardiac CT intraluminal visualization. J Cardiovasc Comput Tomogr. 2020;14(3):272–274. doi: 10.1016/j.jcct.2019.09.019. [DOI] [PubMed] [Google Scholar]
- 18.Su T., Zhang Z., Chen Y., Wang Y., Li Y., Xu M., Wang J., Li J., Tian X., Jin Z. Dark-blood computed tomography angiography combined with deep learning reconstruction for cervical artery wall imaging in takayasu arteritis. Korean J Radiol. 2024;25(4):384–394. doi: 10.3348/kjr.2023.1078. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Guo W., Tripathi P., Yang S., Qian J., Rai B., Zeng M. Modified subtraction coronary CT angiography with a two-breathhold technique: Image quality and diagnostic accuracy in patients with coronary calcifications. Korean J Radiol. 2019;20(7):1146–1155. doi: 10.3348/kjr.2018.0845. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Qiao J., Li S., Yang H., Chen X., Zhu T., Li Q., Wan W., Xu Y., Ge B., Zhao Y., Tang Y., Li F., He Y., Xia L. Subtraction improves the accuracy of coronary CT angiography in patients with severe calcifications in identifying moderate and severe stenosis: A multicenter study. Acad Radiol. 2023;30(12):2801–2810. doi: 10.1016/j.acra.2022.11.033. [DOI] [PubMed] [Google Scholar]
- 21.Kidoh M., Utsunomiya D., Oda S., Yuki H., Funama Y., Namimoto T., Yamamuro M., Yamashita Y. Optimized subtraction coronary CT angiography protocol for clinical use with short breath-holding time-initial experience. Acad Radiol. 2015;22(1):117–120. doi: 10.1016/j.acra.2014.09.020. [DOI] [PubMed] [Google Scholar]
- 22.De Santis D., Jin K.N., Schoepf U.J., Grant K.L., De Cecco C.N., Nance J.W., Vogl T.J., Laghi A., Albrecht M.H. Heavily calcified coronary arteries. Invest Radiol. 2018;53(2):103–109. doi: 10.1097/RLI.0000000000000416. [DOI] [PubMed] [Google Scholar]
- 23.Xu C., Yi Y., Han Y., Xie H., Lu X., Vembar M., Leiner T., Jin Z., Wang Y. Incremental improvement of diagnostic performance of coronary CT angiography for the assessment of coronary stenosis in the presence of calcium using a dual-layer spectral detector CT: Validation by invasive coronary angiography. Int J Cardiovasc Imaging. 2021;37(8):2561–2572. doi: 10.1007/s10554-021-02205-3. [DOI] [PubMed] [Google Scholar]
- 24.Stehli J., Clerc O.F., Fuchs T.A., Possner M., Gräni C., Benz D.C., Buechel R.R., Kaufmann P.A. Impact of monochromatic coronary computed tomography angiography from single-source dual-energy CT on coronary stenosis quantification. J Cardiovasc Comput Tomogr. 2016;10(2):135–140. doi: 10.1016/j.jcct.2015.12.008. [DOI] [PubMed] [Google Scholar]
- 25.Hering D.A., Kröger K., Bauer R.W., Eich H.T., Haverkamp U. Comparison of virtual non-contrast dual-energy CT and a true non-contrast CT for contouring in radiotherapy of 3D printed lung tumour models in motion: A phantom study. Br J Radiol. 2020;93(1116):20200152. doi: 10.1259/bjr.20200152. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Kalisz K., Buethe J., Saboo S.S., Abbara S., Halliburton S., Rajiah P. Artifacts at cardiac CT: Physics and solutions. Radiographics. 2016;36(7):2064–2083. doi: 10.1148/rg.2016160079. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
All the data and supporting information is provided within the article.