Abstract
As uranium is a health hazard for nuclear fuel workers, correct dose assessments are necessary to ensure worker safety. Absorption parameters of uranium aerosols are important parameters for the dose assessments. In this study, size-fractionated uranium aerosols of uranium hexafluoride (UF6), ammonium uranyl carbonate (AUC), uranium dioxide (UO2), and uranium octoxide (U3O8) collected from four workshops at a nuclear fuel fabrication plant were used in two separate in vitro dissolution models, one with simulated lung-lining fluid (Gamble’s fluid) and one with simulated phagolysosomal fluid (PSF). The dissolution characteristics in the different simulated lung environments were assessed. Lung absorption parameters: the rapid fraction (fr), rapid rate (sr, d-1), and slow rate (ss, d-1) were derived, and the dosimetric impact was evaluated. The conversion workshop has a known presence of uranium aerosols of both soluble (UF6, AUC) and relatively insoluble (UO2) compounds. Absorption parameters derived for dissolution in Gamble’s fluid in comparison to dissolution in PSF showed a mixed pattern with impactor stages. Absorption parameters fr, sr, and ss were generally slightly lower in PSF. However, a higher slow rate in comparison to Gamble’s fluid was derived in PSF for some impactor cut-points, indicative of the different solubilities of the mixed aerosols. The fr, sr, and ss derived in PSF ranged between 0.1-0.3, 4-16 d-1, and 0.004-0.015 d-1, respectively. At the powder preparations and pelletizing workshops, less soluble uranium aerosols UO2 and U3O8, are present. The absorption parameters derived for the pelletizing workshop from PSF were fr: 0.02-0.025, sr:4-6 d-1, and ss: 0.0007-0.001 d-1. For the powder preparations workshops, the fr ranged between 0.01-0.045, sr ranged between 4-32 d-1, and ss ranged between 0.002-0.004 d-1. The slow rates derived in PSF were several times higher than for Gamble’s fluid, which resulted in ss: 0.00009-0.0004 d-1 and ss: 0.0001-0.001 d-1 for powder preparations and pelletizing workshops, respectively. The slow rate derived from dissolution in PSF showed good agreement with available in vivo data from studies performed at the pelletizing workshop. For the BA pelletizing workshop with UO2 and U3O8 aerosols that are blended with Gd2O3, fr, sr, and ss ranged between, 0.05-0.1, 1-7 d-1 and 0.002-0.005 d-1, respectively. No substantial differences in derived parameters for dissolution in PSF or Gamble’s fluid were visible. The difference between dissolution patterns in the two fluids between aerosols from the BA pelletizing and from the other two workshops are believed to be related to differences in the specific surface area (SSA), differences in the mixture of uranium compounds, and the blending with Gd2O3. No significant correlation between absorption parameters and impactor stages was found in any of the solutions for the four workshops, with the exception of ss for powder preparation workshop in PSF (R2=0.76, p=0.03). The general conclusions, when evaluating absorption parameters derived for each workshop in PSF and in Gamble’s fluid, were that the parameter most impacted by the type of lung fluid was the slow rate ss and that the effect was most significant for more insoluble uranium. The findings in this study demonstrate that in vitro dissolution in simulated phagolysomal fluid give more realistic estimates of absorption parameters for relatively insoluble material, such as UO2 and U3O8, that are more in line with in vivo data than in vitro dissolution in simulated lung lining fluid.
Keywords: dose, internal, lungs, human, nuclear fuel cycle, uranium
INTRODUCTION
With the increasing demand for fossil-free energy, a shift is underway to more nuclear power. The International Energy Agency (IEA) is projecting a record-high nuclear power output in the next several years (IEA 2024). Subsequently, with this comes an expansion of the nuclear fuel cycle industry. Workers in this industry are exposed to potentially hazardous substances through inhalation of uranium particulate matter. Uranium exposure is associated with both chemical and radiological effects such as kidney damage and risk for radiologically induced cancers. However, the relationship between cancer risk and organ dose has not yet been fully elucidated (ICRP 2021).
For adequate protection of nuclear fuel industry workers and to ensure compliance with regulations, worker exposure is regularly monitored, and the radiation dose is estimated (ICRP 2015). Individual monitoring of internal exposure usually consists of measurements of urine activity and/or external counting of lung activity. Estimates of dose such as the committed effective dose (CED) and the committed equivalent lung dose (Hlung) are derived from said measurements using biokinetic models from the International Commission on Radiological Protection (ICRP) (ICRP 1994, 2006, 2015, 2017). The models, the Human Respiratory Tract Model (HRTM) (ICRP 1994, 2015) and the Human Alimentary Tract Model (HATM) (ICRP 2006), describe the distribution, retention, excretion and uptake of material inhaled and ingested, respectively. In addition, the systemic model describes the distribution, retention, and excretion of material absorbed into blood (ICRP 2017). The HRTM and the HATM models require input parameters related to the physical and chemical properties of the inhaled material, such as the activity median aerodynamic diameter (AMAD) and the solubility of the chemical compound. Default values for input parameters are provided by ICRP, but for more accurate dose estimations, it is recommended to acquire material-specific input parameters (ICRP 2015).
This study relates to a nuclear fuel fabrication plant that employs a less common method of wet-route conversion of uranium hexafluoride (UF6) to uranium dioxide (UO2) via ammonium uranyl carbonate (AUC). There are four major workshops at the plant. In the first, the conversion workshop, uranium compounds such as AUC, UO2, and UF6, which in contact with moisture in the atmosphere or in the respiratory tract forms uranyl fluoride (UO2F2), are present. In the three other workshops, the powder preparation workshop, pelletizing workshop, and burnable absorber (BA) pelletizing workshop, UO2 and uranium oxtocide (U3O8) are present. In the BA pelletizing workshop, gadolinium oxide (Gd2O3) is mixed with the uranium oxides (Hansson et al. 2017). UF6 is classified by the ICRP as fast absorbed (Type F), UO2 and U3O8 as intermediate moderately to relatively insoluble material, while for AUC there is no classification available (ICRP 2017).
Previous studies at the site have investigated properties of the exposure such as the chemical compounds (Hansson et al. 2017), the size distribution (Hansson et al. 2020), and absorption parameters (Hansson et al. 2022; Yusuf et al. 2023, 2024).
The deposition of inhaled particles in the respiratory tract is governed by particle size, with larger particles more likely to deposit in the upper lung regions and smaller particles in the deeper alveolar regions. The deposited matter is then subject to several transport mechanisms, (1) mucociliary clearance of particles and macrophages to the gastrointestinal tract, (2) dissolution in the lung lining fluid, (3) phagocytosis and dissolution in the intracellular environment in macrophages, and (4) transport to the lymph nodes or the interstitium (Guilmette 1998; ICRP 2015). The time-dependent dissolution in the lung is described by a simple compartment model in the HRTM (ICRP 2015):
| (1) |
where N0 is the undissolved activity at time 0 and N(t) is the undissolved activity at time t. A fraction (fr) is rapidly dissolved with the rate of sr, and the remaining fraction is dissolved with a slower rate (ss).
Particles that deposit in the lungs are very likely to be subject to phagocytosis by both airway and alveolar macrophages depending on the deposition site and the solubility of the material. It is reported that a substantial fraction of particles deposited in the respiratory tract are engulfed by macrophages within the first day. A study of rat subjects showed that within the first 24 h, more than 90% of the lavageble Pu was found in the macrophages. Similar results were seen for inhalation of iron oxide in rats and rabbits (Ansoborlo et al. 1999; Guilmette 1998).
In the intracellular environment, the phagolysosomal fluid significantly differs from that of the extracellular lung lining fluid with regard to chemical composition, complexing agents, and pH level. The lung lining fluid contains more complexing agents than the phagolysosomal fluid but has less oxidizing potential. The phagolysosomal fluid has a more acidic environment (pH of 4.5-5) compared to the near-neutral lung lining fluid (pH of about 7.3) (Ansoborlo et al. 1999; Innes et al. 2021). Poncy et al. (1992) investigated the dissolution of U3O8 in baboon alveolar macrophages and found a reduced dissolution, which was attributed to the precipitation of soluble uranium to uranium phosphate. The presence of uranium phosphate was also seen in rat alveolar macrophages subjected to UO2 and U3O8, with increasing uranium phosphate observed for more soluble uranium (Hengé-Napoli et al. 1996).
These factors all influence the dissolution of the inhaled material, making it essential to evaluate the dissolution in the intracellular environment, how it differs from the dissolution in the extracellular environment and the impact on in vitro derived absorption parameters. The ICRP also states in the HRTM that the dissolution rate in alveolar macrophages could be the rate-determining step in the absorption of more insoluble material (ICRP 1994).
Lung absorption parameters, the rapid fraction fr, the rapid dissolution rate sr, and the slow dissolution rate ss were derived by Hansson et al. (2022) for the four workshops at the uranium fabrication plant using a static in vitro lung dissolution model with simulated extracellular fluid. However, a following long-term follow-up study of retired workers indicated a faster slow dissolution rate (ss=0.008 d-1) for exposure to UO2 and U3O8 than that estimated from the in vitro study (ss=0.00007 d-1) (Yusuf et al. 2024). For relatively insoluble to insoluble compounds, the slow dissolution rate is likely to be governed by dissolution in the intracellular environment of macrophages. The incorporation of macrophages to in vitro studies has been reported to influence the dissolution rate and be useful for the prediction of the slow dissolution rate of relatively insoluble to insoluble compounds (Henge-Napoli et al. 1994; Poncy et al. 1992).
Particle-related properties, such as the specific surface area (SSA), density, porosity and size, also have an influence on the dissolution rate. Chazel et al. (1998) investigated the effect the SSA had on the dissolution of U3O8 particles, which showed an increasing solubility with larger SSA. It can be theorized that smaller particles dissolve faster than larger particles due to the larger surface-to-volume ratio. However, in the previous extracellular in vitro study, it was not possible to deduce a significant correlation between particle size and absorption parameter. It was believed that other particle-related properties such as the presence of a mixture of compounds with different size distributions or the SSA had a stronger influence on the dissolution (Hansson et al. 2022).
The aim of the present study is to evaluate the particle size related dissolution in the intracellular environment of lung macrophages and how it relates to the dissolution in the extracellular environment. Uranium particulate matter was collected from four workshops at a nuclear fuel fabrication plant using portable cascade impactors. In vitro dissolution experiments in simulated phagolysosomal lung fluid and lung lining fluid were conducted. Lung absorption parameters were then derived for nine different particle size ranges, and a dosimetric evaluation was conducted.
MATERIALS AND METHODS
Uranium sampling
Uranium aerosols were collected from four workshops at the plant: (1) the conversion workshop, (2) the powder preparation workshop, (3) the pelletizing workshop, and (4) the BA pelletizing workshop. In these workshops, (1) the incoming UF6 is converted to UO2 powder; (2) the powder is milled and blended and waste is oxidized; (2) pellets are produced after pressing, sintering, and grinding the UO2 powder; and (2) pellets are produced after pressing, sintering, and grinding the UO2 powder mixed with U3O8 and gadolinium oxide (Gd2O3). A more detailed description of the plant and workshops can be found in Hansson et al. (2017).
The uranium used at the site originates from low-enriched fuel. The enrichment levels, evaluated in a previous study by Yusuf et al. (2024), ranged between 3.7% and 4.6% 235U, with a mean enrichment of 3.85% over a 5-y period.
As the aim was to collect particles reflecting worker exposure situations, personal cascade impactors (Marple 298; Thermo Scientific, Waltham, MA) with Gillian 500 sampling pumps (Sensidyne, St. Petersburg, FL) were used for the sampling. The impactors were attached to the workers’ collars. The impactor had eight stages with cut-points based on aerodynamic size of 21.3, 14.8, 9.8, 6, 3.5, 1.55, 0.93, and 0.52 µm. The different impactor stages were equipped with mixed cellulose ester (MCE) (Thermo Scientific; SEC-290-MCE) impaction substrates and the last stage with polyvinyl chloride (PVC) filters (Thermo Scientific; SEF-290-P5). Sampling times varied between 16 and 48 h. When the sampling was completed, the substrates and filter were removed and measured for the total alpha activity using an LB 790 10-channel α-β Low-Level Counter (Berthold Technologies, Bad Wildbad, Germany). The substrates and filters were then stored in vacuum-sealed containers to reduce the risk of oxidization prior to the dissolution experiments. A more detailed description of the sampling methodology is available in Hansson et al. (2022).
Dissolution experiment
A static in vitro model with simulated phagolysosomal lung fluid (PSF), developed by (Stefaniak et al. 2005) was chosen (Table 1). The method has been widely used in recent years and has shown a good correlation with in vivo and cell data (Innes et al. 2021). For the dissolution in lung lining fluid, the widely used Gamble’s fluid (Table 2) was chosen (Ansoborlo et al. 1999). The duration of the dissolution experiments was set to 30 d to harmonize with the lifespan of alveolar macrophages (Stefaniak et al. 2017).
Table 1.
Phagolysosomal lung fluid (PSF), pH 4.5 adjusted with potassium hydroxide (KOH) 0.1M (Stefaniak et al. 2005).
| Compound | Concentration |
|---|---|
| Sodium phosphate dibasic anhydrous (Na2HPO4) | 142 mg L-1 |
| Sodium chloride (NaCl) | 6650 mg L-1 |
| Sodium sulfate anhydrous (Na2SO4) | 71 mg L-1 |
| Calcium chloride dihydrate (CaCl2 · 2H2O) | 29 mg L-1 |
| Glycine (C2H5NO2) | 450 mg L1 |
| Potassium hydrogen phthalate (KHP) | 4084.6 mg L-1 |
| Alkylbenzyldimethyl ammonium chloride (ABDC) | 50 ppm |
Table 2.
Gamble’s fluid, pH 7.3 adjusted with CO2 gas (Ansoborlo et al.1999).
| Compound | Concentration |
|---|---|
| Sodium phosphate monobasic (NaH2PO4) | 145 mg L-1 |
| Sodium chloride (NaCl) | 6,780 mg L-1 |
| Calcium chloride (CaCl2) | 23.1 mg L-1 |
| Ammonium chloride (NH4Cl) | 535 mg L-1 |
| Sodium bicarbonate (NaHCO3) | 2,290 mg L-1 |
| Glycine (C2H5NO2) | 450 mg L-1 |
| L-Cysteine | 243 mg L-1 |
| Trisodium citrate (Na3C6H5O7) | 52.1 mg L-1 |
From the four cascade impactor samplings, a total of 36 filters were acquired for the four workshops, and these along with four blank filters were used in the dissolution experiments.
Each substrate/filter was divided in half, one half for each fluid (PSF and Gamble’s), and placed in a filter holder sandwiched between two 0.2 µm pore size membrane filters with diameters of 47 mm (Supor-200, P/N 60402; PALL Life Sciences, Westborough, MA). The filter holders were then placed in plastic containers along with 100 g of simulated lung fluid and put in an incubator (INCO 2, Memmert GmbH, Schwabach, Germany) with a constant CO2-level of 5% and temperature of 37 °C. The simulated lung fluid was replaced with fresh fluid regularly (1 h, 3 h, 5 h, 10 h, 1 d, 2 d, 3 d, 7 d, 13 d, 20 d, 30 d).
The pH levels of the simulated lung fluids were regularly monitored before and after every fluid change. For Gamble’s fluid, the average pH level at the start of each period was 7.33 ± 0.05 and rose to an average of 7.62 ± 0.14 after incubation. For the PSF solution, the pH level was stable at 4.54 ± 0.04 for the duration of each dissolution period.
Sample preparation
All collected leaching sample fluids were acidified with 4 mL of concentrated nitric acid for conservation. From these samples, 10 ml aliquots were withdrawn for subsequent uranium analysis by ICP-MS. Finally, 233U tracer, traceable to a 232U standard (National Physical Laboratory, product code R20-02), was added as yield determinant.
After the end of the 30-d leaching period, the filter holders were taken apart and the filter samples along with membrane filters were transferred to glass beakers, together with 2% nitric acid rinse of the filter holders. The samples were then digested with concentrated nitric acid followed by digestion in aqua regia during heating.
Sample analysis: ICP-MS
For the ICP-MS analysis, an Agilent 8900 ICP-MS/MS (Agilent Technologies, Inc., Chicopee, MA) in single quadrupole mode and broad peak resolution was used. Rinse solutions of 3% HNO3 were run before and after each sample to clean the system. Acid blanks of 3% HNO3 were run between samples to monitor the background level and detect possible memory effects. Mass numbers of 232, 233, 235, and 238 were analyzed for each sample, and a uranium isotopic reference standard IRMM-074/1 was regularly run to monitor the isotopic ratio of 233U, 235U, and 238U. The mass number 232 was used to monitor the 232Th levels as its hydride 232Th1H+ can affect the levels of the mass number 233. The mean count-rate ratio of mass numbers 232/233 for our samples were calculated to be 1.8 ± 1.4. Since the expected 232Th1H+/232Th+ is approx. 6.6 × 10−5, the contribution from 232Th1H+ could therefore be considered negligible (Hansson et al. 2022).
Replicate data were evaluated for outliers using Grubbs’s outlier test, and the detected outliers (5% significance level) were excluded (Grubbs 1969). The 233U, 235U and 238U mean count rates for each sample were calculated and background corrected by subtracting the count rate for prior measured 3% HNO3 acid blank samples and corrected for the tracer signal contribution based on measurements of a tracer blank. The 235U and 238U total content (µg) in each leached 100 g sample were calculated based on the known 233U tracer amount and corrected for the corresponding procedural blank content.
Sample analysis: alpha spectrometry
To each remaining fluid with aerosol filter sample, 232U tracer (Isotrak, AEA Technology, PLC, Didcot, UK) was added as yield determinant and the uranium was radiochemically separated with liquid-liquid extraction by tributyl phosphate (TBP). Thereafter, the samples were electrodeposited on stainless steel discs (Hallstadius 1984) and analyzed by ORTEC (Oak Ridge, TN) Octête plus alpha spectrometers with passivated implanted planar silicon detectors (Canberra PIPS, Mirion Technologies Inc, San Ramon, CA) with ORTEC Maestro software. The measurement time ranged between 3 and 29 d, and the average chemical recovery was 58%. The 238U activities (Bq) were evaluated and blank-adjusted.
A selection of samples (N=32) were analyzed with both alpha spectrometry and ICP-MS in order to evaluate the agreement between 238U concentration measured with the two different methods. The results showed good agreement between the two methods with a mean ratio (238Uα-spec/238UICP-MS) of 0.97 ± 0.07.
Data analysis
One-sided t-test was used to determine if a sample concentration was detectable; i.e., if sample concentration was significantly higher than corresponding blank concentration at 5% significance level, prior to procedural blank subtraction.
For each substrate/filter, (1) the accumulated dissolved 238U amount was calculated at each time point, (2) the dissolution rate (µg d-1) was calculated as the dissolved 238U amount (µg) in each sample divided by the time (d) in solvent, and (3) the undissolved fraction N(t)/N0 at each time point was then calculated from the accumulated dissolved 238U amount and the initial uranium content N0, as derived from the sum of the 238U amount (µg) in all leached samples and the substrate/filters.
From the dissolution rate, some outlying results (N=44, i.e., approx. 6% of the samples) were discovered with unusually high dissolution rates, which is believed to be explained by particle escape from the membrane filters (Hansson et al. 2022). These were identified as samples where the dissolution rate was more than three standard deviations away from the trend (defined as the mean from two adjacent samples) and were corrected for by substituting said outlying data point with the corresponding trend value.
Uncertainties were derived using the Monte Carlo method (JCGM 2008). Monte Carlo simulations were run 50,000 times for each sample; a Gaussian distribution was assigned for count rates and a rectangular distribution for weight and tracer concentrations.
The absorption parameters (fr, sr, and ss) were derived by fitting the undissolved fractions per substrate/filter using a non-linear regression model (MATLAB 2024) to eqn (1). The Monte Carlo method was used, and the curve-fitting for each impactor stage was performed 5,000 times. The absorption parameters and uncertainties were acquired for each impactor stage as the mean and standard deviation of the 5,000 estimates.
Dose evaluation
The Taurus (v. 1.3) (Public Health England, Chilton, UK) software for internal dosimetry was used to derive dose estimations of the resulting absorption parameters. Taurus implements the ICRP’s biokinetic models for dose calculations of internal exposure to uranium. As a previous study of the uranium exposure indicated bimodal size distributions (Hansson et al. 2020), a fine and coarse fraction made up of impactor stages with cut points <5µm and cut-points ≥5µm, respectively, was assumed. The committed effective dose (CED) and the lung equivalent dose (Hlung) after the inhalation of 1 Bq 234U were estimated for each workshop, using AMAD of both 5 and 15 µm, and absorption parameters derived for each type of lung fluid. The isotope 234U was chosen for dosimetric calculations as it is the main contributor to uranium alpha activity at the site, approximately 80% (Yusuf et al. 2024).
RESULTS
The 238U procedural blank levels for the leached samples measured with ICP-MS ranged between 0.002-0.082 ng mL-1. Of 792 leached samples analyzed, 768 samples had detectable 238U levels (i.e., were significantly above procedural blank 238U levels and the levels ranged between 0.0001-5.2 ng mL-1). The 238U activities for substrate/filter samples measured with alpha spectrometry were converted to mass using the specific activity 12,437 Bq g-1 (Meija et al. 2016). Of the 80 substrates and filters, 72 substrate/filter samples were correctly processed and had levels ranging between 0.099-12.9 µg, with procedural blank levels between 0.032-0.047 µg. The 8 filters that were incorrectly processed (i.e., radiochemically processed without yield determinant) belonged to the BA pelletizing and pelletizing workshops. Data on dissolution for some particle sizes in Gamble’s fluid and PSF, respectively, are therefore missing.
Undissolved fraction
Data on the undissolved fractions for all aerosol samples in simulated phagolysosomal lung fluid and lung lining fluid are presented in Appendix Figs. A1 and A2. Data on the undissolved fraction over time for selected cut-points for each workshop and for each type of lung fluid are displayed in Figs. 1 and 2. For the conversion workshop, where uranium compounds such as UO2, AUC, and the more soluble UF6 are present, the dissolution is shown to be faster in Gamble’s fluid than in PSF, with a more marked difference between impactor stages in Gamble’s fluid. The undissolved fractions after 30 d ranged between 0.39-0.70 and 0.51-0.78 in Gamble’s fluid and PSF, respectively.
Fig. 1.

Undissolved fraction over time and fitted curves for uranium aerosol samples from the conversion and the BA pelletizing workshops in simulated phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s). Data for three selected cut-points are displayed. For the BA pelletizing, data is missing for 0.52 µm in Gamble’s fluid due to problems during the chemical processing of the final filter samples. Error bars correspond to ± one standard deviation.
Fig. 2.

Undissolved fraction over time and fitted curves for uranium aerosol samples from the powder preparation and the pelletizing workshops in simulated phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s). Data for three selected cut-points are displayed. For the pelletizing workshop data is missing for impactor cut-points 0.52 and 21.3 µm in PSF. For powder preparation a fitted curve for impactor cut-point <0.52 µm in PSF could not be derived, due to several samples being below the detection limit. Error bars correspond to ± one standard deviation.
The dissolution of aerosols acquired from the powder preparation and pelletizing, where the less soluble compounds UO2 and U3O8 are present, was shown to be dissolved slightly faster in PSF than in Gamble’s fluid. Also, here the difference in dissolution between impactor stages was more pronounced in Gamble’s fluid than PSF. The undissolved fractions ranged between 0.86-0.94 and 0.89-0.97 for the aerosols from the powder preparation workshop in PSF and Gamble’s fluid, respectively. The undissolved fractions ranged between 0.95-99 for the aerosols from the pelletizing workshop in Gamble’s fluid. For the dissolution in PSF, the undissolved fraction ranged between 0.94-0.97. However, data for the cut-points 0.52, 0.93 and 21.3 µm were missing.
The undissolved fraction in PSF for the BA pelletizing workshop ranged between 0.78-0.90 and showed the same trend as the results for the pelletizing and powder preparation workshops, with generally lower undissolved fractions in PSF than in Gamble’s fluid.
Absorption parameters
Fig. 3 shows absorption parameters (fr, sr, and ss) over impactor size cut-points for the conversion and BA pelletizing workshops in PSF and Gamble’s fluid.
Fig. 3.

Absorption parameters (fr, sr, and ss) derived from dissolution in phagolysosomal lung fluid (PSF) and surface lining fluid (Gamble’s), as a function of impactor size cut-point for the conversion and BA pelletizing workshops. For the BA pelletizing workshop data is missing for impactor cut-points <0.52, 0.52, 0.93, 1.55 and 14.8 µm in Gamble’s fluid, due to problems during the chemical processing of the final filter samples.
For the conversion workshop, a generally high fr > 0.2 for most impactor stages are estimated, with the fr being lower in PSF. The rapid rate ranges between 5-29 d-1 and is also generally higher in Gamble’s fluid than PSF. The slow rate shows a mixed pattern where the rate is higher in PSF for larger impactor cut-points, i.e., larger particles but the same is not seen for smaller impactor cut-points with the exception of the 0.52 µm cut-point. The ss ranged between 0.006-0.009 d-1 and 0.004-0.015 d-1 in Gamble’s fluid and PSF, respectively.
For the BA pelletizing workshop, data were available for all impactor stages in PSF but only for cut-points 3.5, 6, 9.8, and 21.3 µm in Gamble’s fluid. The results for fr and sr show small differences between Gamble’s fluid and PSF, with tendencies of slightly higher fr and sr in PSF in comparison to Gamble’s fluid for available cut-points. For the slow rate, a trend of higher ss in PSF is shown. The fr ranged between 0.04-0.1, the sr ranged between 1-22 d-1, and the ss ranged between 0.002-0.005 d-1 for the BA pelletizing workshop in PSF.
Absorption parameters for the powder preparation and pelletizing workshops are shown in Fig. 4. For the powder preparation workshop, the results for the rapid fraction fr showed a trend of slightly higher fr for Gamble’s fluid, which was most clearly seen for stages 0.52 and 0.93 µm. The results for the rapid rate indicated an overall slightly higher sr for PSF, although the difference for some impactor stages was small. The uncertainties for the sr, derived for two impactor stages 0.52 and 6 µm, were large (>70%). The slow rate in PSF and Gamble’s fluid ranged between 0.002-0.004 d-1 and 0.0001-0.001 d-1, respectively, indicating an 8 times higher ss in PSF in comparison to Gamble’s fluid.
Fig. 4.

Absorption parameters (fr, sr, and ss) derived from dissolution in phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s), as a function of impactor size cut-point for the powder preparation and pelletizing workshops. For the pelletizing workshop data is missing for impactor cut-points 0.52, 0.93 and 21.3 µm in PSF, due to problems during the chemical processing of the final filter samples. For the powder preparation workshop it was not possible to acquire a good fit for impactor cut-point <0.52 µm in PSF due to several data points being below detection limit.
The results for the pelletizing workshop showed a slightly higher fr in PSF in comparison to Gamble’s fluid, ranging between 0.016-0.024 and 0.012-0.039, respectively. The rapid rate ranged between 4-6 d-1 and 0.62-5.4 d-1 in PSF and Gamble’s fluid, respectively. The results for the slow rate indicated a higher ss in PSF in comparison to Gamble’s fluid, with ss ranging between 0.0006-0.001 d-1 and 0.00009-0.0004 d-1, respectively. However, data for impactor stages 0.52, 0.93 and 21.3 µm in PSF were not available.
No significant correlation between absorption parameters and impactor stages was found in any of the solutions for the four workshops, with the exception of ss for the powder preparation workshop in PSF (R2=0.76, p=0.03).
Dose evaluation
The CED per Bq and the Hlung per Bq for each workshop and each type of lung fluid are shown in Table 3. The comparison coefficients for ICRP reference absorption types are shown in Table 4. Dose estimates indicate that for more insoluble compounds, such as the aerosols from the powder preparation and pelletizing workshops, the CED per Bq and the Hlung per Bq are approximately 60% lower using absorption parameters derived from the PSF in comparison to using absorption parameters derived from dissolution in Gamble’s fluid, irrespective of AMAD. For the BA pelletizing workshop, the dose coefficients for an AMAD 15 µm are approximately 20% lower in PSF when comparing to Gamble’s fluid. For the conversion workshop, 33% higher dose coefficients are derived for the fine fraction in PSF in comparison to Gamble’s fluid, while for the coarse fraction, the dose coefficients were similar for dissolution in PSF and Gamble’s fluid.
Table 3.
Dose coefficients (CED and Hlung) for 1 Bq 234U were estimated using the Taurus software for inhalation intakes, for all workshops and AMADs 15 and 5 µm, respectively. Absorption parameters (fr,sr, and ss) for each workshop were derived from the dissolution in phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s). Absorption parameters for the coarse fraction (approximated by an AMAD 15 µm), were calculated as the weighted mean of absorption parameters from cut-points 6-21.3 µm (weighted by the fraction of total activity deposited at each impactor stage). Absorption parameters for fine fraction (approximated by an AMAD 5 µm) were calculated as the weighted mean of absorption parameters from cut-points <0.52-3 µm. The alimentary tract transfer factor (fA) was calculated as 0.02×fr.
| Workshop | Impactor stages (n) |
AMAD (µm) |
fr (-) | SD | sr (d-1) | SD | ss (d-1) | SD | fA (-) | SD | CED Coefficient (µSv Bq-1) |
Hlung (µSv Bq-1) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Lung lining fluid (Gamble’s fluid) | ||||||||||||
| Conversion | 5 | 5 | 0.223 | 0.004 | 8.6 | 0.4 | 0.0093 | 0.0003 | 0.0045 | 0.00007 | 1.0 | 6.2 |
| BA pelletizing a | — | 5 | ||||||||||
| Powder preparation | 5 | 5 | 0.034 | 0.002 | 3.6 | 0.4 | 0.00028 | 0.00008 | 0.0007 | 0.00003 | 7.5 | 44.6 |
| Pelletizing | 5 | 5 | 0.0195 | 0.0009 | 2.2 | 0.2 | 0.00019 | 0.00005 | 0.0004 | 0.00002 | 9.4 | 55.9 |
| Conversion | 4 | 15 | 0.405 | 0.005 | 17.4 | 0.8 | 0.0063 | 0.0003 | 0.0081 | 0.00010 | 0.5 | 2.0 |
| BA pelletizing a | 3 | 15 | 0.058 | 0.001 | 0.91 | 0.04 | 0.00266 | 0.00007 | 0.0012 | 0.00002 | 1.1 | 4.7 |
| Powder preparation | 4 | 15 | 0.0303 | 0.0006 | 2.9 | 0.1 | 0.00053 | 0.00003 | 0.0006 | 0.00001 | 2.6 | 10.1 |
| Pelletizing | 4 | 15 | 0.0130 | 0.0006 | 3.8 | 0.5 | 0.00013 | 0.00004 | 0.0003 | 0.00001 | 4.8 | 20.8 |
| Phagolysosomal lung fluid (PSF) | ||||||||||||
| Conversion | 5 | 5 | 0.177 | 0.004 | 9.2 | 0.5 | 0.0060 | 0.0003 | 0.0035 | 0.00007 | 1.3 | 8.3 |
| BA pelletizing | 5 | 5 | 0.095 | 0.003 | 1.27 | 0.09 | 0.0040 | 0.0002 | 0.0019 | 0.00006 | 1.8 | 11.3 |
| Powder preparation b | 4 | 5 | 0.023 | 0.001 | 8 | 7 | 0.0022 | 0.0001 | 0.0005 | 0.00002 | 2.7 | 16.3 |
| Pelletizing c | 3 | 5 | 0.019 | 0.001 | 5 | 1 | 0.0009 | 0.0001 | 0.0004 | 0.00003 | 4.2 | 25.0 |
| Conversion | 4 | 15 | 0.266 | 0.004 | 7.9 | 0.3 | 0.0097 | 0.0003 | 0.0053 | 0.00008 | 0.4 | 2.0 |
| BA pelletizing | 4 | 15 | 0.0607 | 0.002 | 1.5 | 0.1 | 0.0038 | 0.0001 | 0.0012 | 0.00003 | 0.9 | 3.9 |
| Powder preparation b | 4 | 15 | 0.0202 | 0.0007 | 12 | 5 | 0.00341 | 0.00009 | 0.0004 | 0.00001 | 1.0 | 4.3 |
| Pelletizing c | 3 | 15 | 0.0208 | 0.0009 | 5.4 | 0.7 | 0.00082 | 0.00007 | 0.0004 | 0.00002 | 2.1 | 8.3 |
For coarse fraction in Gamble’s fluid, data for 14.8 µm is missing and for the fine fraction parameters could not be derived as 4 of 5 data points were missing.
For the fine fraction data for <0.52 µm was not included, as absorption parameters could not be derived due several samples being below the detection limit.
For the coarse fraction in PSF, data for 21.3 µm is missing and for fine fraction in PSF, data for 0.52 and 0.93 µm are missing.
Table 4.
Reference ICRP parameters from ICRP (2017).
| AMAD (µm) | fr (-) | sr (d-1) | ss (d-1) | fA (-) | CED coefficient (µSv Bq-1) |
Hlung (µSv Bq-1) |
|
|---|---|---|---|---|---|---|---|
| ICRP Type F | 5 | 1 | 10 | 0.02 | 0.25 | 0.23 | |
| ICRP Type F/M | 5 | 0.8 | 1 | 0.01 | 0.016 | 0.41 | 2.1 |
| ICRP Type M | 5 | 0.2 | 3 | 0.005 | 0.004 | 1.4 | 8.9 |
| ICRP Type M/S | 5 | 0.03 | 1 | 0.0005 | 0.0006 | 5.5 | 33 |
| ICRP Type S | 5 | 0.01 | 3 | 0.0001 | 0.0002 | 13 | 78 |
| ICRP Type F | 15 | 1 | 10 | 0.02 | 0.16 | 0.1 | |
| ICRP Type F/M | 15 | 0.8 | 1 | 0.01 | 0.016 | 0.18 | 0.7 |
| ICRP Type M | 15 | 0.2 | 3 | 0.005 | 0.004 | 0.65 | 2.9 |
| ICRP Type M/S | 15 | 0.03 | 1 | 0.0005 | 0.0006 | 2.6 | 10 |
| ICRP Type S | 15 | 0.01 | 3 | 0.0001 | 0.0002 | 5.4 | 24 |
DISCUSSION
The main objectives of the present study were to explore the difference in dissolution capabilities of phagolysosomal fluid and lung lining fluid and the impact on lung absorption parameters for soluble and relatively insoluble size-differentiated uranium aerosols.
Conversion workshop
For the conversion workshop, the undissolved fraction was lower in Gamble’s fluid, and a more prominent difference between particle sizes was visually discernable. The aerosols from the conversion workshop contain both soluble uranium, such as UF6 (which in contact with moisture forms UO2F2), AUC, and more insoluble uranium such as UO2. Hexavalent uranium (U6+) has higher solubility that increases in carbonate-rich and high pH solutions, such as the Gamble’s fluid (Hettiarachchi et al. 2019; Sutton and Burastero 2004). This could explain why aerosols from the conversion workshop with hexavalent uranium, such as UF6 and UO2F2, are more dissolvable in Gamble’s fluid than in PSF. Another explanation is that the phosphate concentration of the PSF in the acidic environment governs the dissolution, and with such phosphate complexation comes also a risk of precipitation of soluble uranium to uranium phosphate, which has been discussed in other studies (Guilmette et al. 2000; Hengé-Napoli et al. 1996; Poncy et al. 1992; Sutton and Burastero 2004).
Rapid fractions fr of 0.1-0.5 were derived in both lung fluids, consistent with moderate to relatively soluble material (i.e., Type M to Type F/M). Derived rapid rates, sr >5 d-1, were also indicative of soluble materiel (i.e., Type F). For the slow rate ss, the estimations ranged between 0.004-0.015 d-1, consistent with moderate to relatively soluble material (i.e., Type M to Type F/M). The fr and sr were 20% lower in PSF than Gamble’s fluid, while the ss was on average 60% higher in PSF for impactor cut-points 0.52, 9.8-21.3 µm and lower for all other cut-points. This varying effect on ss in the different fluids is believed to be due to the known presence of a mixture of soluble and insoluble compounds of different particle sizes. Hansson et al. (2022) performed an in vitro study in Gamble’s fluid using aerosols from the same four workshops with a longer study duration (100 d). The results for the conversion workshop indicated similar fr and sr as in the present study, i.e., Type M to Type F/M and Type F, respectively. The estimates of ss (0.0008 d-1) are low in comparison to the present study and more resembled Type M/S (ss=0.0005 d-1).
Powder preparation and pelletizing workshops
For the powder preparation and pelletizing workshops with the less soluble uranium aerosols UO2 and U3O8, the undissolved fractions were comparably high in both solutions and showed a slightly lower undissolved fraction in PSF (approx. 4%).
Looking at the results for the absorption parameters, estimated fr suggested Type S to Type M/S. The rapid rates for both workshops were higher than for Type M/S, suggesting Type M to Type F. The results for the slow rate were very interesting, as the data for powder preparation in PSF (0.002-0.004 d-1) resembled Type M/S (ss=0.0005 d-1) to Type M (ss=0.005 d-1), while data for Gamble’s fluid (0.0001-0.001 d-1) suggested Type S (ss=0.0001 d-1) to Type M/S. The ss data for pelletizing suggested Type S to Type M/S in Gamble’s fluid (0.00009-0.0004 d-1) and Type M/S in PSF (0.0007-0.001 d-1), displaying on average seven times higher slow rate in PSF in comparison to Gamble’s fluid. The findings in this study in Gamble’s fluid are consistent with the fr, sr, and ss parameters estimates found in previous study by Hansson et al. (2022) of Type S to M/S, Type M/S to F, and Type S to Type M/S, respectively. The resulting higher ss in PSF is more in line with findings in other studies and the ICRP recommended ss of 0.0005 d-1 (Chazel et al. 2000; Davesne and Blanchardon 2014; ICRP 2017; Sdraulig et al. 2008).
The slow rate was also evaluated in two previous studies. One study involved long-term urinary excretion of uranium for two retired workers from the same nuclear fabrication plant, one previously working at the pelletizing workshop, resulted in an ss=0.0008 d-1 for the pelletizing workshop. A second study evaluated absorption parameters from urinary excretion data for 38 workers at the same pelletizing workshop, which resulted in ss=0.001 d-1. Those findings are considerably higher than the results found for dissolution in Gamble’s fluid and are more in line with the results for the slow rate in PSF. This corroborates the hypothesis that the intracellular dissolution in macrophages governs the absorption of insoluble material in the deep lungs.
BA pelletizing workshop
In the BA pelletizing workshop, the UO2 and U3O8 are blended with Gd2O3 and processed through compacting and granulation, which is then added with lubricant (Hansson et al. 2017). The results indicate lower undissolved fractions than for aerosols from powder preparation and pelletizing workshops. The absorption parameters derived for the BA pelletizing workshop in PSF, with fr (0.05-0.1), sr (1-7 d-1) and ss (0.002-0.005 d-1), point to Type M to Type M/S material. The absorption parameters that were derived for particle sizes with data available for both fluids were 3.5-9.8, and 21.3 µm. For these data points, differences between parameters derived for the two lung fluids were modest, and no substantial difference in the slow rate as seen for the other two workshops with UO2 and U2O8 was evident. This can be related to several factors that influence the dissolution: (1) differences in manufacturing process, which affects the SSA, (2) differences in the mixture of UO2 and U3O8, which have atoms in different states, i.e., U4+ and U5+(a mix of U4+ and U6+), where oxidation plays a more important role in the dissolution of the former, and (3) the blending with Gd2O3, which can increase the oxidation resistance and thereby influence dissolution in environments where the oxidation potential is important (Casella et al. 2016; Chazel et al. 1998, 2000; Glazoff et al. 2016; Guilmette et al. 2000; Scheele et al. 2021).
The variation in dissolution behavior between uranium oxides from different workshops may partly be due to differences in SSA. As uranium oxides with larger SSA can dissolve faster due to larger surface area available for contact with the dissolving fluid (Chazel et al. 1998, 2000). The different processing steps at the workshops, such as milling, pressing, and sintering, affect the SSA of the uranium particle and can be an explanation to part of the differences seen in the dissolution behavior between aerosols from the powder processing and pelletizing workshops.
The presence of Gd2O3 in the aerosols from the BA pelletizing workshop likely influence the dissolution behavior of the uranium oxides as it suppresses the oxidation-driven dissolution, which could explain why the difference in dissolution rates between the PSF and Gamble’s fluid was not as apparent for the BA pelletizing workshop as it was for uranium oxides from the other workshops.
Dose evaluation
The slow rate has a strong impact on dose estimates, and larger discrepancies are found in dose estimates for the powder preparation and pelletizing workshops when comparing CED and Hlung derived using absorption parameters estimated in PSF to those for Gamble’s fluid. The CED and the Hlung will be overestimated if the ss derived for insoluble uranium is highly underestimated as it is in Gamble’s fluid. This gives a strong argument for the importance of including the dissolution in macrophages, especially when deriving absorption parameters for insoluble material.
Uncertainties
A comprehensive discussion of the uncertainties related to the methodology can be found in Hansson et al. (2022). An in-depth discussion of the uncertainties associated with representing the in vivo lung environment using the two in vitro models is provided in Yusuf (2024). The relevance and possible impact of some of the main uncertainties will be briefly discussed.
Particle size
To acquire size differentiated particles, cascade impactors were employed. The impactor stages are defined so that the given cut-point represents the aerodynamic particle size with a 50% probability of impaction (Thermo Fisher Scientific Inc 2009). This means that adjacent stages will have some overlap containing particles of the same aerodynamic size. There is also the previously mentioned presence of agglomerated particles at higher cut-points along with larger particles impacting on lower cut-points due to particles bouncing. In combination, these effects give rise to uncertainties in the particle size represented by the impactor stages, which could interfere with the detection of a possible relationship between particle size and dissolution.
In vitro dissolution methods
To simulate extracellular lung fluid, the Gamble’s fluid was used, chosen in part to harmonize with a previous study (Hansson et al. 2022) and in part due to it being a classic medium for assessment of dissolution in the lung environment (Ansoborlo et al. 1999). A main concern when using the Gamble’ fluid is the preservation of the pH during the course of the dissolution experiment. The longest period between fluid changes in this study was 10 d in the final sampling. To ensure that pH levels did not drift too much during the experiments, an incubator with 5% CO2 gas was used. The maximal pH drift between two fluid changes was 0.44 from 7.28 to 7.72. This was deemed acceptable as the expected impact on the solubility with said drift is believed to be minimal (Hansson et al. 2022; Sutton and Burastero 2004).
To simulate phagolysosomal lung fluid, the PSF developed by Stefaniak et al. (2005) was chosen. The fluid has the pH level of the inner environment of phagolysosomes, while the ionic composition in parts was based on the serum ultrafiltrate (SUF) developed by Guldberg et al. (1998) and in parts the Gamble fluid. The KHP buffer is believed to have reduced the pH variation during the experiments, as the maximal pH drift between fluid changes was 0.05.
Duration of dissolution experiments
There were several limiting factors in determining the adequate time length for the dissolution experiments. As shown in a previous study by Hansson et al. (2022), the risk of particle penetration and membrane filter degradation increases with the duration of the dissolution experiment, mainly day 40 and later. However, a short experimental time in relation to insoluble particles with dissolution half-times of >1,000 d could involve a greater uncertainty and an overestimation of the slow rate parameter. For this study, a duration of 30 d was chosen to harmonize with the lifespan of alveolar macrophages and to minimize the risk of particle penetration and membrane filter degradation. As previously mentioned, no effect on the slow rate for insoluble uranium due to study duration was evident when comparing to results of the previous study with 100-d duration (Hansson et al. 2022). Some evidence of particle penetration/leakage was found, as 6% of the samples displayed unexpectedly increased dissolution rates. However, this was not concentrated to later time points but occurred randomly. The increased dissolution rates were corrected for as mentioned in the Methods section.
CONCLUSION
In this study, in vitro dissolution in simulated lung fluids was compared for lung-lining fluid (Gamble’s fluid) and phagolysosomal fluid (PSF). The dissolution of uranium aerosols (UF6, UO2, and U3O8) from four workshops at a nuclear fuel fabrication plant in the different lung fluids was evaluated.
The results showed a difference in the dissolution pattern between Gamble’s fluid and PSF, both for soluble and for more insoluble uranium particles, where dissolution was slightly slower in PSF for soluble uranium and faster for insoluble uranium. The general conclusion when evaluating absorption parameters derived for each workshop in PSF and in Gamble’s fluid was that the parameter most impacted by the type of lung fluid was the slow rate ss and that the effect was most significant for more insoluble uranium.
The comparison of dissolution in different types of lung fluids is a good method for a deeper understanding of the dissolution characteristics of different uranium compounds and to acquire better estimates of absorption parameters.
In vitro dissolution in phagolysosomal fluid gives more realistic estimates of absorption parameters for relatively insoluble materials such as UO2 and U3O8, which are more in line with in vivo data than parameters derived from in vitro dissolution in Gamble’s fluid.
Acknowledgments
Westinghouse Electric Sweden AB is acknowledged for participation in the study. Special thanks to Tu Mai and operators at the plants for helping with the aerosol sampling. Thanks to Marie Carlsson for helping with fluid changes.
The Swedish Radiation Safety Authority (grant number SSM2016-589-2) offered support for this research.
APPENDIX
Data on undissolved uranium on filter after completion of dissolution experiment as measured with alpha spectrometry are presented in Table A1. Complete data on the undissolved fractions over time for all workshops are presented in Figs. A1 and A2.
Table A1.
Alpha spectrometry measurement data of 238U activity on filter after dissolution experiment, i.e., undissolved uranium.
| Workshop | Impactor stage cut-point (µm) | 238U (Bq) | Gamble | 238U (µg) | SD | 238U (Bq) | PSF | 238U (µg) | SD |
|---|---|---|---|---|---|---|---|---|---|
| SD | SD | ||||||||
| BA pelletizing | 21.3 | 0.0227 | 0.0007 | 1.83 | 0.06 | 0.0287 | 0.0007 | 2.31 | 0.05 |
| 14.8 | 0.0226 | 0.0006 | 1.82 | 0.05 | |||||
| 9.8 | 0.147 | 0.001 | 11.80 | 0.09 | 0.125 | 0.002 | 10.1 | 0.2 | |
| 6 | 0.160 | 0.001 | 12.86 | 0.10 | 0.119 | 0.002 | 9.6 | 0.1 | |
| 3.5 | 0.125 | 0.002 | 10.0 | 0.2 | 0.086 | 0.002 | 6.9 | 0.1 | |
| 1.55 | 0.0508 | 0.0008 | 4.09 | 0.07 | |||||
| 0.93 | 0.0068 | 0.0002 | 0.55 | 0.02 | |||||
| 0.52 | 0.0029 | 0.0001 | 0.23 | 0.01 | |||||
| 0.25 | 0.0054 | 0.0003 | 0.43 | 0.02 | |||||
| Conversion | 21.3 | 0.0049 | 0.0001 | 0.39 | 0.01 | 0.0044 | 0.0001 | 0.36 | 0.01 |
| 14.8 | 0.0073 | 0.0002 | 0.59 | 0.01 | 0.0066 | 0.0002 | 0.53 | 0.02 | |
| 9.8 | 0.0082 | 0.0003 | 0.66 | 0.02 | 0.0091 | 0.0002 | 0.73 | 0.02 | |
| 6 | 0.0048 | 0.0002 | 0.39 | 0.02 | 0.0036 | 0.0001 | 0.29 | 0.01 | |
| 3.5 | 0.0039 | 0.0002 | 0.32 | 0.01 | 0.0052 | 0.0001 | 0.42 | 0.01 | |
| 1.55 | 0.0099 | 0.0003 | 0.79 | 0.02 | 0.0138 | 0.0004 | 1.11 | 0.04 | |
| 0.93 | 0.0059 | 0.0003 | 0.47 | 0.02 | 0.0056 | 0.0003 | 0.45 | 0.02 | |
| 0.52 | 0.0019 | 0.0001 | 0.149 | 0.009 | 0.0023 | 0.0001 | 0.19 | 0.01 | |
| 0.25 | 0.0089 | 0.0003 | 0.71 | 0.03 | 0.0064 | 0.0002 | 0.52 | 0.02 | |
| Pelletizing | 21.3 | 0.0043 | 0.0002 | 0.35 | 0.02 | ||||
| 14.8 | 0.0050 | 0.0001 | 0.40 | 0.01 | 0.0042 | 0.0002 | 0.34 | 0.01 | |
| 9.8 | 0.0064 | 0.0002 | 0.51 | 0.01 | 0.0089 | 0.0002 | 0.71 | 0.02 | |
| 6 | 0.0077 | 0.0003 | 0.62 | 0.02 | 0.0080 | 0.0002 | 0.65 | 0.02 | |
| 3.5 | 0.0059 | 0.0003 | 0.47 | 0.02 | 0.0048 | 0.0002 | 0.39 | 0.01 | |
| 1.55 | 0.0041 | 0.0001 | 0.33 | 0.01 | 0.0037 | 0.0001 | 0.30 | 0.01 | |
| 0.93 | 0.0023 | 0.0001 | 0.19 | 0.01 | |||||
| 0.52 | 0.0031 | 0.0002 | 0.25 | 0.01 | |||||
| 0.25 | 0.0069 | 0.0002 | 0.55 | 0.01 | 0.0049 | 0.0002 | 0.39 | 0.02 | |
| Powder preparation | 21.3 | 0.0111 | 0.0003 | 0.90 | 0.02 | 0.0110 | 0.0003 | 0.89 | 0.03 |
| 14.8 | 0.0150 | 0.0005 | 1.20 | 0.04 | 0.0135 | 0.0004 | 1.09 | 0.03 | |
| 9.8 | 0.0137 | 0.0004 | 1.10 | 0.03 | 0.0221 | 0.0006 | 1.78 | 0.05 | |
| 6 | 0.0106 | 0.0002 | 0.85 | 0.02 | 0.0192 | 0.0006 | 1.55 | 0.04 | |
| 3.5 | 0.0071 | 0.0003 | 0.57 | 0.02 | 0.0100 | 0.0003 | 0.80 | 0.02 | |
| 1.55 | 0.0074 | 0.0003 | 0.60 | 0.02 | 0.0061 | 0.0003 | 0.49 | 0.02 | |
| 0.93 | 0.0017 | 0.0001 | 0.133 | 0.009 | 0.0023 | 0.0001 | 0.18 | 0.01 | |
| 0.52 | 0.00123 | 0.00007 | 0.099 | 0.006 | 0.0021 | 0.0002 | 0.17 | 0.01 | |
| 0.25 | 0.00230 | 0.00009 | 0.185 | 0.007 | 0.0020 | 0.0001 | 0.16 | 0.01 |
Fig. A1.

Undissolved fraction over time and fitted curves for uranium aerosol samples from the conversion and BA pelletizing workshops in simulated phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s). Data for all impactor cut-points are displayed. Data for the BA pelletizing workshop for cut-points <0.52-1.55 and 14.8 µm in Gamble’s fluid are missing due to an error during chemical processing. Error bars correspond to ± one standard deviation.
Fig. A2.

Undissolved fraction over time and fitted curves for uranium aerosol samples from the powder preparation and pelletizing workshops in simulated phagolysosomal lung fluid (PSF) and lung lining fluid (Gamble’s). Data for all impactor cut-points are displayed. Data for the pelletizing workshop for cut-points 0.52, 0.93 and 21.3 µm in Gamble’s fluid are missing due to an error during chemical processing. Error bars correspond to ± one standard deviation. For powder preparation a fitted curve for impactor cut-point <0.52 µm in PSF could not be derived, due to several samples being below the detection limit.
Footnotes
(Manuscript accepted 1 December 2025)
References
- Ansoborlo E, Henge-Napoli M, Chazel V, Gibert R, Guilmette R. Review and critical analysis of available in vitro dissolution tests. Health Phys 77:638-645; 1999. [DOI] [PubMed] [Google Scholar]
- Casella A, Hanson B, Miller W. The effect of fuel chemistry on UO2 dissolution. J Nucl Mater 476:45-55; 2016. [Google Scholar]
- Chazel V, Houpert P, Ansoborlo E. Effect of U3O8 specific surface area on in vitro dissolution, biokinetics, and dose coefficients. Radiat Prot Dosim 79:39-42; 1998. [Google Scholar]
- Chazel V, Houpert P, Ansorbolo E, Henge-Napoli M, Paquet F. Variation of solubility, biokinetics and dose coefficient of industrial uranium oxides according to the specific surface area. Radiat Prot Dosim 88:223-231; 2000. [Google Scholar]
- Davesne E, Blanchardon E. Physico-chemical characteristics of uranium compounds: a review. Int J Radiat Biol 90:975-988; 2014. [DOI] [PubMed] [Google Scholar]
- Glazoff MV, van Rooyen IJ, Coryell BD, Parga CJ. Comparison of nuclear fuels for treat: UO2 vs U3O8. Idaho: Idaho National Laboratory; No. INL/EXT-16-37972; 2016. [Google Scholar]
- Grubbs FE. Procedures for detecting outlying observations in samples. Technometrics 11:1-21; 1969. [Google Scholar]
- Guilmette RA. Issues and research on the biochemistry of inhaled actinides. J Alloys Compd 271-273:66-71; 1998. [Google Scholar]
- Guilmette RA, Hoover MD, Newton GJ, Howard RJ, Ortiz RN, Thomas JM, Trotter SM. The effect of in vitro dissolution system parameters for measuring the solubility of uranium aerosols. IRPA 10 [online]. 2000. Available at https://www.irpa.net/irpa10/cdrom/00780.pdf. Accessed 24 August 2024. [Google Scholar]
- Guldberg M, Christensen VR, Perander M, Zoitos B, Koenig AR, Sebastian K. Measurement of in-vitro fibre dissolution rate at acidic pH. Ann Occup Hyg 42:233-243; 1998. [Google Scholar]
- Hallstadius L. A method for the electrodeposition of actinides. Nucl Instrum Methods Phys Res 223:266-267; 1984. [Google Scholar]
- Hansson E, Pettersson HB, Yusuf I, Roos P, Lindahl P, Eriksson M. Particle size-dependent dissolution of uranium aerosols in simulated lung fluid: a case study in a nuclear fuel fabrication plant. Health Phys 123:11-27; 2022. [DOI] [PubMed] [Google Scholar]
- Hansson E, Pettersson HBL, Eriksson M. Uranium aerosol activity size distributions at a nuclear fuel fabrication plant. Health Phys 119:327-341; 2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Hansson E, Pettersson HBL, Fortin C, Eriksson M. Uranium aerosols at a nuclear fuel fabrication plant: characterization using scanning electron microscopy and energy dispersive x-ray spectroscopy. Spectrochim Acta Part B 131:130-137; 2017. [Google Scholar]
- Henge-Napoli M, Ansoborlo E, Donnadieu-Claraz M, Berry J, Gibert R, Mondan A, Pradal B. Solubility and transferability of several industrial forms of uranium oxides. Radiat Prot Dosim 53:157-161; 1994. [Google Scholar]
- Hengé-Napoli MH, Ansoborlo E, Claraz M, Berry JP, Cheynet MC. Role of alveolar macrophages in the dissolution of two different industrial uranium oxides. Cell Mol Biol Noisy--Gd Fr 42:413-420; 1996. [PubMed] [Google Scholar]
- Hettiarachchi E, Paul S, Cadol D, Frey B, Rubasinghege G. Mineralogy controlled dissolution of uranium from airborne dust in simulated lung fluids (SLFs) and possible health implications. Environ Sci Technol Lett 6:62-67; 2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- ICRP. Human respiratory tract model for radiological protection. Oxford: Pergamon Press; ICRP Publication 66, Ann. ICRP 24; 1994. [Google Scholar]
- ICRP. Human alimentary tract model for radiological protection. Oxford: Pergamon Press; ICRP Publication 100, Ann. ICRP 36 (1-2); 2006. [DOI] [PubMed] [Google Scholar]
- ICRP. Occupational intakes of radionuclides: part 1. Oxford: Pergamon Press; ICRP Publication 130, Ann. ICRP 44(2); 2015. [DOI] [PubMed] [Google Scholar]
- ICRP. Occupational intakes of radionuclides: part 3. Oxford: Pergamon Press; ICRP Publication 137, Ann. ICRP 46(3/4); 2017. [DOI] [PubMed] [Google Scholar]
- ICRP. Cancer risks from plutonium and uranium exposure. Oxford: Pergamon Press; ICRP Publication 150, Ann. ICRP 50(4); 2021. [DOI] [PubMed] [Google Scholar]
- IEA. Electricity 2024 — analysis and forecast to 2026. Paris: IEA; 2024. [Google Scholar]
- Innes E, Yiu HH, McLean P, Brown W, Boyles M. Simulated biological fluids — a systematic review of their biological relevance and use in relation to inhalation toxicology of particles and fibres. Crit Rev Toxicol 51:217-248; 2021. [DOI] [PubMed] [Google Scholar]
- JCGM. Evaluation of measurement data — supplement 1 to the “Guide to the expression of uncertainty in measurement” — propagation of distributions using a Monte Carlo method. JCGM 101:2008; 2008. Available at https://www.bipm.org/en/doi/10.59161/jcgm101-2008. Accessed 2 December 2020. [Google Scholar]
- MATLAB. 24.1.0.2537033 R2024A. Natick, MA: The MathWorks Inc.; 2024. [Google Scholar]
- Meija J, Coplen TB, Berglund M, Brand WA, De Bièvre P, Gröning M, Holden NE, Irrgeher J, Loss RD, Walczyk T. Atomic weights of the elements 2013 (IUPAC Technical Report). Pure Appl Chem 88:265-291; 2016. [Google Scholar]
- Poncy J-L, Metivier H, Dhilly M, Verry M, Masse R. In vitro dissolution of uranium oxide by baboon alveolar macrophages. Environ Health Perspect 97:127-130; 1992. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Scheele RD, Hanson BD, Casella AM. Effect of added gadolinium oxide on the thermal air oxidation of uranium dioxide. J Nucl Mater 552:153008; 2021. [Google Scholar]
- Sdraulig S, Franich R, Tinker R, Solomon S, O’Brien R, Johnston P. In vitro dissolution studies of uranium bearing material in simulated lung fluid. J Environ Radioact 99:527-538; 2008. [DOI] [PubMed] [Google Scholar]
- Stefaniak A, Guilmette R, Day G, Hoover M, Breysse P, Scripsick R. Characterization of phagolysosomal simulant fluid for study of beryllium aerosol particle dissolution. Toxicol In Vitro 19:123-134; 2005. [DOI] [PubMed] [Google Scholar]
- Stefaniak AB, Virji MA, Badding MA, Cummings KJ. Application of the ICRP respiratory tract model to estimate pulmonary retention of industrially sampled indium-containing dusts. Inhal Toxicol 29:169-178; 2017. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sutton M, Burastero SR. Uranium (VI) solubility and speciation in simulated elemental human biological fluids. Chem Res Toxicol 17:1468-1480; 2004. [DOI] [PubMed] [Google Scholar]
- Thermo Fisher Scientific Inc. Marpel personal cascade impactors series 290: Instruction manual Part number 100065-00. 2009. [Google Scholar]
- Yusuf I, Hansson E, Eriksson M, Lindahl P, Pettersson HBL. Uranium body clearance kinetics — a long-term follow-up study of retired nuclear fuel workers. Health Phys 127:520-535; 2024. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yusuf I, Hansson E, Eriksson M, Roos P, Lindahl P, Pettersson HBL. Particle size dependent dissolution of uranium aerosols in simulated gastrointestinal fluids. Health Phys 124:285-300; 2023. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Yusuf I. Uranium biokinetics and internal dosimetry. Linköping University Electronic Press; 2024. Dissertation. DOI:10.3384/9789180758260. [Google Scholar]