Skip to main content
PLOS One logoLink to PLOS One
. 2026 Sep 25;21(9):e0359160. doi: 10.1371/journal.pone.0359160

Biometric verification using oral acoustic reflections

Amit Kam 1,*, Nir Iakoby 2, Daniel Tubiana 1, Eran Hochstadter 1, Roi Ram 1, Yaniv Zigel 2
Editor: Diego A Forero3
PMCID: PMC13614562  PMID: 42789573

Abstract

Biometric verification methods, such as voice, face, iris and fingerprint verification, are commonly used in smartphones, security systems, and medical devices. However, each involves tradeoffs in cost, accuracy, latency and susceptibility to spoofing. We present and report laboratory testing of Oral Cavity Acoustic Verification (OCAV), a biometric verification system that transmits sound waves into the user’s oral cavity, characterizes the acoustic response, and returns a verification decision by comparing the acoustic response to the individual’s prerecorded acoustic signature. A total of 108 healthy volunteers aged 18–60 years were recruited, and a unique acoustic profile was created for each participant. Across three recording sessions conducted one week apart, 20,860 genuine trials and 18,880 impostor trials were collected to evaluate verification accuracy. Verification accuracy was 90.1% for a single trial and 95.2% when pooling 5 consecutive trials. Unlike voice biometrics that depend on speech production and are sensitive to acoustic noise and audio playback attacks, OCAV exploits an active acoustic response from the oral cavity that may be less vulnerable to spoofing attacks. In contrast to other audio-based systems such as ear-canal acoustic biometrics, OCAV is intended for devices that already involve oral cavity contact. The potential applications include inhaler-based health monitoring, breath-alcohol tests, and the enforcement of nicotine-use restrictions. These capabilities can help support public health and safety efforts; for example, by monitoring youth access to e-vaping or detecting drivers’ alcohol consumption prior to ignition.

Introduction

Biometric technologies such as voice, face, iris, and fingerprint recognition have become integral parts of modern access control and security systems [1,2].

Related literature

Current biometric technologies involve tradeoffs between processing speed, hardware requirements, accuracy and vulnerability to spoofing. Voice recognition, for example, is highly susceptible to spoofing [3] and environmental noise [4]. Longer speech samples typically trade off speed for accuracy: studies show that the median equal-error rate (EER) drops from 23% in 2-second samples to 3% in 10-second samples [5]. Fingerprint recognition, which is known for its high accuracy, nevertheless requires specialized hardware and depends on fingerprint quality [6]. Accuracy rates range from approximately 98–99% when using advanced scanners and algorithms to 85–90% with small area capacitive sensors and simpler algorithms. Facial recognition achieves  ~ 99% accuracy in controlled tests but only 92–96% on unconstrained benchmarks when these include occlusions, pose changes, and varied lighting [7]. These systems also require high-resolution cameras and substantial computational resources, which can increase verification latency [8]. Controlled iris image-capture recognition is one of the highest-performing biometric modalities. In the NIST IREX IX evaluation, the most accurate one-to-one iris matcher achieved an estimated false-rejection rate of 0.57% at a false-acceptance rate of 0.001% [9]. However, iris recognition typically requires iris-specific imaging hardware, often near-infrared illumination, and cooperative eye positioning. Recent ear-canal acoustic methods report about 95–98% accuracy with 1–2% EER under the authors’ test conditions [10,11], thus highlighting the potential of acoustic biometrics for user verification. Table 1 summarizes different biometric approaches and highlights their limitations.

Table 1. Summary of related biometric approaches.

Biometric approach General methodology Reported performance/context Requirements and limitations
Voice Uses speech signals produced via the vocal tract and speaker-specific articulation patterns EER decreases with longer speech samples, from approximately 23% in 2-second samples to 3% in 10-second samples [5] Requires speech production, is sensitive to environmental noise and channel mismatch, and is vulnerable to replay/spoofing attacks [3,4]
Fingerprint Uses ridge-pattern images captured by a contact sensor High accuracy with advanced sensors (98–99%), but lower performance with small-area capacitive sensors (85–90%) Requires specialized contact hardware and depends on sensor quality and clear ridge detail [6]
Face Uses camera-based anatomical image capture and image-matching algorithms Approximately 99% accuracy in controlled tests, decreasing to about 92–96% on unconstrained benchmarks that include occlusion, pose changes, and varied lighting [7] Requires unobstructed imaging, suitable lighting, and camera hardware
Iris Uses iris-pattern image capture, typically with iris-specific imaging hardware and near-infrared illumination Very high verification performance under controlled iris-image capture; NIST IREX IX reported an estimated false-rejection rate of 0.57% at a false-acceptance rate of 0.001% for the most accurate one-to-one iris matcher [9] Requires cooperative eye positioning, sufficient iris focus and resolution, limited occlusion from eyelids/eyelashes/reflections, and iris-specific imaging hardware
Ear-canal acoustic Emits an acoustic signal into the ear canal and analyzes the reflected response Recent acoustic ear-canal systems report approximately 95–98% accuracy and 1–2% EER under the authors’ test conditions [10,11] Requires ear-canal access and is not naturally aligned with oral substance-exchange devices

Two recent surveys of biometrics for IoT devices identified ultra-low-power operation, protection of the biometric signature templates, and resilience to spoofing [12,13] as the three most persistent challenges and also underscored that current solutions tend to be based on cameras or fingerprint sensors that result in additional hardware overhead and on-device processing latency.

Aside from their utilization in security and access control, applications of biometric technologies are increasingly being explored for healthcare and substance-use monitoring. A recent systematic review of real-time patient identification evaluated fingerprint, face, and iris systems on accuracy, response time, usability, privacy, hygiene, safety, and operational factors [14]. An expert commentary argued that biometrics can reduce identification errors and improve safety, while highlighting infrastructure, privacy, and patient acceptance as key implementation constraints [15]. Other potential uses include preventing underage misuse of electronic cigarettes or vapes by identifying the designated user [16]. In cars that have a breathalyzer to test the alcohol level of the driver before ignition, biometric devices can confirm that the person taking the test is the actual driver [17]. These widely different uses demonstrate the versatility of biometric technologies beyond traditional security roles and confirm their relevance to public health and safety.

Study objective and main contribution

The main goal of this study was to develop and evaluate a low-cost, oral-acoustic biometric verification system that delivers sub-second, spoof-resistant user verification on resource-constrained devices. This article describes the Oral Cavity Acoustic Verification system (OCAV), a new biometric approach and device that capitalizes on oral cavity acoustic reflections generated during natural user inhalation to securely identify users. To the best of our knowledge, oral cavity acoustic reflections have never been implemented in biometric verification. By embedding authentication in the user’s natural inhalation behavior, the OCAV system enhances security with minimal user effort. The technology can be applied to multiple cases, including with important public health and safety applications such as eliminating spoof identification in electronic nicotine delivery systems (“vapes”), preventing breathalyzer spoofing, and validating patient identity in medical inhalers. By aligning biometric verification with habitual user behaviors at the point of oral substance exchange, the OCAV combines user-facing identification with a secure authentication method. Since verification takes place during inhalation, the OCAV system ensures that the authenticated individual is the one inhaling. For example, integrating this technology into e‑cigarettes could prevent unauthorized, including underage, use of e-cigarettes, by conducting an identity verification test at each inhalation (Fig 1).

Fig 1. The oral cavity acoustics verification system concept integrated into an electronic cigarette.

Fig 1

This feasibility study makes three main contributions:

  • Presents an oral acoustic verification approach that uses inhalation-triggered acoustic reflections from the oral cavity for user verification.

  • Describes the experimental workflow, including profile enrollment, transfer-function estimation, feature extraction, and verification scoring.

  • Evaluates the approach on a multi-session cohort of adult participants and reports genuine/impostor verification performance, including accuracy, AUC, EER, and subgroup analyses.

Materials and methods

Study design

A prospective study was conducted from December 2023 to April 2024 at the Biomedical Signal Processing Research Laboratory, Ben-Gurion University of the Negev, Israel, to evaluate the performance of the OCAV system.

Sampling and participants.

A total of 108 healthy adult participants were recruited for this study between December 17, 2023 and April 15, 2024, primarily from postings at Ben Gurion University of the Negev. They ranged in age from 18 to 60 and were evenly stratified into three age groups (18–30, 31–43, and 44–60), with 36 participants in each group.

Ethics.

Each participant was provided with detailed information about the trial, its purpose, procedures, and potential risks, and signed an informed consent form prior to participation. To protect participant confidentiality, participant data were key-coded using serial numbers (e.g., A001_171223). The study protocol was approved by the Ben‑Gurion University Human Subjects Research Committee (approval no. 467‑3). All procedures adhered to the Committee’s guidelines. Written informed consent was obtained from each participant before enrollment.

Safety and compliance: Safety measures were stringently enforced throughout the study to safeguard the well-being of all participants. Although there were no imminent risks to the participants in any form, at the end of each session, rigorous sterilization procedures were undertaken for each mouthpiece, accompanied by appropriate labeling for accurate identification of the respective participant’s mouthpiece allocation. The paramount concern throughout the study was stringent adherence to safety protocols and regulatory standards.

Eligibility criteria and demographics.

Candidates were excluded if pregnant, had any type of facial malformation that prevented full closure of the mouth on the mouthpiece or surgery or procedures affecting mouth structure. Table 2 lists the participants’ age, BMI, gender, and smoking status by age group.

Table 2. Demographics by age group (μ±σ).
Ages 18–30 Ages 31–43 Ages 44–60
Age (years) 25.6±1.7 36.1±3.9 50.7±5
BMI (kg/m2) 23±2.9 24.9±4.3 26.4±4.6
No. male (female) subjects 12 (24) 9 (27) 7 (29)
No. smokers (non-smokers) 16 (20) 15 (21) 14 (22)

The inhalation device

The OCAV device resembles an e-cigarette (Fig 2) and measures 120 mm × 20 mm × 15 mm (weight ≈ 35 g). It is pharmacologically inert and contains no nicotine, propylene glycol, vegetable glycerin, or flavoring additives commonly found in commercial e-liquids. It is powered by a rechargeable battery (connected via USB Type-C) and has a removable mouthpiece. The mouthpiece is 3D printed from biocompatible materials, ensuring safety during contact with bodily tissues. During the study, each participant was assigned a personal, dedicated mouthpiece that was sterilized between visits and discarded after the final session. The device is activated when the participant inhales. The inhalation-induced drop in internal pressure activates the pressure sensor, which then prompts the speakerphone to emit a 50 ms chirp (2–8 kHz) acoustic signal. Simultaneously, the on-board microphone captures the acoustic echoes from the participant’s oral cavity and digitizes them at 44.1 kHz (16 bit/sample) before streaming to a laptop for analysis.

Fig 2. The oral cavity acoustic verification device: front, side and top views.

Fig 2

(A) Device without mouthpiece, (B) Mouthpiece, (C) Device assembled with mouthpiece, (D) Schematic diagram labelling main components.

The OCAV system maps the acoustic transfer function (frequency-response curve) of the individual’s oral cavity by analyzing inhalation-triggered echo signals. Because each person’s oral-cavity geometry is different, it produces a characteristic acoustic transfer function. To verify identity, each new recording is compared to the participant’s stored profile generated during registration.

Feature extraction.

An oral acoustic reflection signal is recorded from each inhalation, y(n). Fig 3 illustrates a typical acoustic reflection, displayed as both a time-domain waveform and its spectrogram.

Fig 3. Typical oral acoustic reflection signal.

Fig 3

(A) time-domain waveform and (B) spectrogram.

The oral cavity is modeled as a linear-time-invariant (LTI) acoustic system with frequency response H(jω), as described in previous vocal-tract acoustics studies [18,19]. Because the transmitted signal was known and the oral reflected signal was captured, the transfer function can be estimated by dividing the Fourier spectra (4096-point FFT, Hann window) of the reflected signal, Y(jω)=F{y(n)}, and the transmitted signal, X(jω)=F{x(n)}, as shown in Eq. (1) and illustrated in Fig 4.

Fig 4. Oral cavity modulation.

Fig 4

H^(jω)=Y(jω)X(jω) (1)

Fig 5 compares the magnitude of the estimated transfer functions of two representative participants to illustrate the inter-subject variability exploited by the verification model.

Fig 5. Estimated Transfer functions of two different participants.

Fig 5

The estimated transfer function was also used to reconstruct the components of the recording explained by the oral acoustic response. As defined in Eq. 2, when y(n) is the recorded signal, x(n) is the transmitted chirp and h^(n)=F−1{H^(jω)} is the impulse response corresponding to the estimated transfer function, the reconstructed response y^(n) and recording residual r(n) is as follows:

y^(n)=x(n)*h^(n)r(n)=y(n)−y^(n) (2)

A 342-dimensional descriptive feature vector is then extracted from each estimated transfer function by concatenating the predefined descriptor groups into a single representation. This feature set summarizes the acoustic response in terms of the spectral magnitude patterns across the analyzed frequency range, the spectral structure of the early reflection component, the frequency-banded recording-residual characteristics, and permitted the extraction of global signal-quality measures such as clean-signal power, recording-noise power, and the SNR to capture the stable shape of the oral acoustic response and recording quality information. Dimensionality reduction was not applied in the current study before classification to preserve the direct interpretability of the predefined acoustic-response and signal-quality descriptors.

Enrollment process: Personal profile formation.

During user registration, 20 consecutive inhalation-triggered recordings were obtained from each participant. These recordings were processed as illustrated in Fig 6. For each recording, a descriptive feature vector was extracted. Outlier feature vectors identified by an Isolation Forest model (200 trees, contamination≈4%) were discarded. Specifically, the Isolation Forest was applied to recording quality features rather than to the final verification classifier output. These quality features included clean signal variance, pairwise consistency measures, correlation, smoothed spectrum deviation, skewness, kurtosis, and spectral flatness. This unsupervised step was used to remove atypical recordings before profile formation. The remaining vectors were averaged elementwise to yield a single representative vector, which was stored as the participant’s profile template.

Fig 6. Registration workflow from inhalation recordings to personal profile creation.

Fig 6

Verification process: Verifying claim of identity.

Upon an identity claim, a single inhalation-triggered recording is captured with the OCAV device. A 342-dimensional feature vector from each verification recording is extracted, using the same spectral energy and bandwidth features as described for profile creation. A comparison feature vector is constructed by pairing the candidate and template vectors and computing similarity-based descriptors. The resulting 242-dimensional comparison feature vector captures the pairwise relationship by concatenating absolute element-wise differences, signed differences, and cosine-normalized distances between the candidate and template features. The comparison vector is fed into a LightGBM gradient-boosted decision-tree classifier (200 trees, learning rate = 0.1), which returns a scalar verification score in the 0–1 range. Fig 7 illustrates the verification workflow, from single inhalation through feature extraction, comparison-vector construction, and LightGBM score output.

Fig 7. Verification workflow.

Fig 7

Classification model

To verify user identity, a Light Gradient Boosting Machine (LightGBM) machine-learning classifier [20] optimized for distributed learning and memory efficiency was implemented [21]. Because LightGBM grows trees leaf-wise by selecting splits that maximize loss reduction, it often outperforms level-wise algorithms such as XGBoost, as shown in finance-sector benchmarks (RMSE = 0.76 vs 0.83) [22].

The comparison between the candidate and profile transfer-function spectra is fed into the LightGBM classifier. For the current study, the LightGBM classifier was trained on a pre-existing in-house dataset of 20,000 comparison vectors (10,000 genuine and 10,000 impostor trials) thereby ensuring a 1:1 class balance. The participants enrolled to generate this training dataset were not included in the 108-participant evaluation cohort reported here. Model development and parameter selection were performed before evaluation and the data from the present study cohort was not used for classifier training to reduce the risk of overfitting to the present cohort.

The LightGBM classifier outputs a verification score on a continuous scale 0 ≤ s ≤ 1, where higher values indicate greater similarity between the recording and the claimed profile. The system compares the verification score to a fixed threshold (τ), where scores ≥ τ are considered as genuine (positive), and otherwise rejected (negative). A positive result is declared when the identity claim is accepted, and a negative result is declared when the claim is rejected. The classifier considers an identity claim to be genuine when it matches the verification recording to the participant’s own profile. A match to any other participant’s profile constitutes a false identity claim, and constitutes an impostor trial.

Experimental protocol

We hypothesized that each participant’s transfer function would be sufficiently distinctive to support identity verification. The experiment was conducted in a quiet office environment. Each participant underwent three consecutive sessions at intervals of approximately one week. During each session, participants took brief inhalations from the device. Participants first completed a structured pre-training session during which proper device use was demonstrated and practiced. The main objective was to instruct the participants to breathe in a uniform manner so that the resulting transfer-function plots would be comparable across trials. The participants were also taught to make sure that the mouthpiece was firmly connected to the device to maintain an airtight seal. This airtight seal also helps prevent background noise from interfering with the received signal. Training began with a provisional profile. Once verified, participants recorded the full 20-inhalation profile (Session 1 only). The testing step collected 80 inhalations. Fig 8 shows example signals obtained from participants’ inhalations using the device.

Fig 8. Acoustic echo waveforms captured during user inhalations.

Fig 8

The dark line represents the current inhalation, and the lighter line shows the immediately preceding inhalations. (A) Consistent inhalations, (B) Inconsistent inhalations, (C) Noisy signals.

Fig 9 shows the data flow from enrollment to analysis. Of the 108 participants, 5 were excluded, leaving 103 profiles (2,060 enrollment recordings) and 23,732 session recordings. Each session recording was paired with its owner’s profile (genuine) and with an impostor profile sampled at random (seed = 42), yielding 47,464 trials. After quality control (variance gate and unsupervised outlier filtering), 39,740 trials remained (20,860 genuine; 18,880 impostor). See S1 Appendix for step counts and rationales.

Fig 9. Data flow.

Fig 9

Performance metrics & statistical analyses.

The primary endpoints for assessing system performance were the overall single-trial accuracy and the area under the receiver operating characteristic (ROC) curve. These endpoints were selected to provide both application-level and threshold-independent performance measures. The secondary metrics included the equal error rate (EER) as well as the precision, recall, and F1 scores. The confidence intervals for these metrics and the ROC curves were computed using bias-corrected bootstrap methods (1,000 samples). Data normality was examined using the Shapiro-Wilk and Kolmogorov-Smirnov tests (significance threshold p < 0.001), which confirmed non-normal distributions. For the two-group comparisons (smokers vs. non-smokers), Mann-Whitney U tests with Bonferroni correction for multiple comparisons were applied. For analyses involving three or more unrelated groups (e.g., age brackets), a Kruskal-Wallis test followed by a Dunn-Bonferroni post hoc correction was utilized. Friedman tests with Nemenyi post hoc analyses were employed to examine repeated-measure effects (across visits). All analyses were conducted using Python 3.9 and associated libraries (NumPy 1.26 [23], Pandas 2.2 [24], SciPy 1.12 [25], scikit-learn 1.5 [26], matplotlib 3.9 [27], seaborn 0.13 [28]). All analyses were done on a standard desktop workstation (Intel Core i7 CPU, 32 GB RAM, no GPU acceleration was required).

Results

The results focused on verifying whether a claimed identity matched the enrolled profile. We report the EER, the operating point where the false-acceptance and false-rejection rates coincided, and overall accuracy. The ROC curve was plotted; i.e., sensitivity (true positive rate) versus the false positive rate to evaluate system discrimination for 20,860 genuine and 18,880 imposters trials (Fig 10). The Area Under the ROC Curve (AUC) was 0.942 (95% CI, bootstrap 0.940–0.944). Fig 11 shows the distribution of the verification scores for all genuine and impostor trials. The analysis implemented two thresholding strategies. First, a global threshold was applied uniformly across all participants, which yielded an overall accuracy of 88%. Then, to explore the system's potential under optimal conditions, we determined individual thresholds for each participant, which yielded an improved accuracy of 90%. Although participant-specific thresholds can enhance performance, they may introduce overfitting and reduce generalizability. Therefore, we report accuracy based on both the global and individual threshold results to provide a comprehensive evaluation. All the analyses and tables below are based on the participant-specific thresholds to illustrate the system's best-case performance. We improved the overall verification accuracy by aggregating up to five consecutive tests, from which we selected the maximum verification score within each window. The accuracy increased from 90.1% for one test to 95.2% for five tests. Each inhalation test required approximately 150 ms to capture and process. Consequently, aggregating five consecutive tests took well under one second (~750ms), confirming that multi-sample authentication remained compatible with real-time applications. Table 3 lists all performance measures from one to five consecutive tests.

Fig 10. ROC curve plot of all data.

Fig 10

The ROC curve illustrates the tradeoff between the true positive rate (sensitivity) and false positive rate (1-specificity) for the OCAV system. Curves farther from the diagonal indicate better genuine/impostor discrimination. Based on 20,860 genuine trials and 18,880 impostor trials from 99 subjects, the AUC was 0.942 (95% CI: 0.940–0.944).

Fig 11. Distribution of verification confidence scores for genuine and impostor trials.

Fig 11

Violin plots depicting the distribution of verification confidence scores. The width of each violin represents the probability density of the data. The central line indicates the median score (value shown), and the inner lines denote the interquartile range. A greater separation between genuine and impostor score distributions indicates better verification discrimination.

Table 3. Consecutive test results (%).

Consecutive tests Accuracy (%) Recall (%) Precision (%) F1 (%) EER (%)
1 90.1 90.2 90.9 90.6 12.5
2 92.5 93.9 92.8 93.4 10.5
3 93.7 96.1 93.5 94.8 9.7
4 94.4 97.0 94.5 95.7 9.3
5 95.2 98.4 94.8 96.6 9.3

Normality test

The normality of the verification confidence scores (n = 39 740) was assessed using Shapiro-Wilk tests (W = 0.55, p < 0.001) and Kolmogorov-Smirnov tests (D = 0.58, p < 0.001), both of which rejected the null hypothesis of a normal distribution. Consequently, non-parametric analyses were employed: Mann-Whitney U tests for two-group comparisons, Kruskal-Wallis tests with Dunn-Bonferroni post hoc corrections for multi-group (age) comparisons, and Friedman tests with Nemenyi post-hoc analyses for repeated-measure comparisons.

Performance by visit

To assess temporal stability, the verification scores were analyzed separately for each of the three weekly sessions (Visit 1: 7,240 genuine and 6,607 impostor tests, visit 2: 6,854 genuine and 6,095 impostor tests, visit 3: 6,766 genuine and 6,178 impostor tests)

Fig 12 presents the ROC curves for Visits 1–3. Fig 13 shows violin plots of the verification-score distributions for genuine and impostor trials across these visits.

Fig 12. ROC plots by visits.

Fig 12

ROC curves for Visit 1, Visit 2 and Visit 3. Each curve plots the true-positive rate (genuine-acceptance rate) against the false-positive rate (impostor-acceptance rate). Curves farther from the diagonal indicate stronger genuine/impostor discrimination. The data are based on 7,240/6,607, 6,854/6,095 and 6,766/6,178 genuine/impostor verification trials for Visits 1–3, respectively. The dashed diagonal indicates chance performance.

Fig 13. Verification-score distributions by visit.

Fig 13

Violin plots showing the similarity-score distributions for genuine (right) and impostor (left) trials across the three weekly sessions. A greater separation between genuine and impostor score distributions indicates better verification discrimination. The central line marks the median; the two outer lines mark the inter-quartile range. Asterisks indicate pair-wise differences that remained significant after Nemenyi correction (*** p < 0.001).

The Friedman test comparing verification scores across the three visits returned a significant difference in genuine scores (χ22 = 73.2, p < 0.001) but no difference in imposter scores (χ22 = 0.06, p = 0.97). Thus., there was a statistically significant difference between visits in the expected true results. There was no significant difference in expected false scores. Given the significant Friedman test results for the expected true scores, pairwise comparisons were conducted using the Nemenyi test to identify which visits differed. The Nemenyi test indicated significant differences between Visit 1 and Visit 2 (p = 0.001) and between Visit 1 and Visit 3 (p = 0.001). There was no significant difference between Visit 2 and Visit 3 (p = 0.53).

Results by age group

To compare system performance across age groups, we created three evaluation subsets. Age Group 1 contributed 7,038 genuine and 6,556 impostor trials; Age Group 2 contributed 6,747 genuine and 6,118 impostor trials; and Age Group 3 contributed 7,075 genuine and 6,206 impostor trials. Performance by age group is presented in Fig 14 as ROC curves. Fig 15 illustrates the verification score distributions across age groups, with brackets indicating statistically significant pairwise differences based on the Kruskal-Wallis and Mann-Whitney U tests.

Fig 14. ROC curves by age groups.

Fig 14

Receiver-operating-characteristic curves for the three age brackets: 18–30 (Group 1), 31–43 (Group 2), and 44–60 (Group 3). Each curve plots the genuine-acceptance rate against the impostor-acceptance rate, derived from 7,038/6,556 (Group 1), 6,747/6,118 (Group 2) and 7,075/6,206 (Group 3) genuine/impostor trials, respectively. Curves farther from the diagonal indicate greater genuine/impostor discrimination.

Fig 15. Violin plots of prediction confidence scores by True Target (False and True) and Age Group.

Fig 15

Violin plots showing similarity-score distributions for genuine (right half of each violin) and impostor (left half) trials across the three age brackets. Each violin represents the distribution of scores for a specific age group within each verification category, genuine or imposter. A greater separation between genuine and impostor score distributions indicates better verification discrimination. Significant differences between age groups are indicated with asterisks above the dotted lines (*p < 0.05).

A Kruskal-Wallis H test revealed a statistically significant difference in verification scores across the three age groups for the expected genuine trials (H = 7.5, p = 0.02). Pairwise comparisons using the Mann-Whitney U test showed a statistically significant difference between Age Group 1 and Age Group 3 after Bonferroni correction (adjusted p = 0.04 < α = 0.05). No significant differences were found between the other pairs of age groups using Mann–Whitney U tests with Bonferroni correction (all adjusted p > 0.05). For the impostor trials, the Kruskal-Wallis H test indicated a significant difference across age groups (H = 6.7, p = 0.034). However, none of the pairwise comparisons between age groups were statistically significant after applying the Bonferroni correction (smallest adjusted p-value = 0.056).

Results by smoker/non-smoker groups

Verification metrics were also stratified by self‑reported smoking history. Smokers were defined as individuals who identified themselves as occasional, intermittent, or non-daily smokers, either currently or in the past. The type of smoked substance was not considered relevant to this analysis. The dataset comprised 8,760 genuine and 8,083 impostor trials from smokers, and 12,100 genuine and 10,797 impostor trials from non‑smokers.

Fig 16 shows the performance by Smokers/Non-Smokers, and Fig 17 shows the distribution of verification scores of the groups; significance in brackets corresponds to the statistical test results between verification scores.

Fig 16. ROC curves for smokers vs. non-smokers.

Fig 16

Receiver-operating-characteristic curves for self-reported smokers and non-smokers. Each curve plots the genuine-acceptance rate against the impostor-acceptance rate. Curves farther from the diagonal indicate better genuine/impostor discrimination. Data are based on 8,760 genuine / 8,083 impostor trials for smokers and 12,100 genuine / 10,797 impostor trials for non-smokers. The dashed diagonal indicates chance performance.

Fig 17. Violin plots showing the distribution of prediction confidence scores by True Target (True or False) and Smoking Status (Smoker vs. Non-Smoker).

Fig 17

Violin plots showing similarity-score distributions for genuine (right half of each violin) and impostor (left half) trials in smokers and non-smokers. A greater separation between genuine and impostor score distributions indicates better verification discrimination. An asterisk marks the only significant difference that survived Bonferroni correction (impostor scores, p < 0.05); the comparison of genuine scores was non-significant.

A Mann-Whitney U test revealed no significant difference in genuine verification scores between smokers and non-smokers (p = 0.83, z = 0.21), but a significant difference in impostor scores (p = 0.02, z = −2.1), with smokers exhibiting higher scores.

Discussion

This study evaluated OCAV, an inhalation-triggered verification system, in 99 adult participants. Using participant-specific thresholds, the OCAV achieved 90.1% single trial verification accuracy, which increased to 95.2% using the max score of five aggregated tests. When using a single global threshold, the single-trial accuracy was 88%. The overall AUC was 0.942 and the single trial EER was 12.5%. These findings suggest that under the conditions tested in this study, OCAV generated reliable biometric verification from oral-cavity acoustic reflections. To the best of our knowledge, biometric verification from oral-cavity acoustic reflections has never been reported. We examined variations across sessions, age, and smoking status. The subgroup analyses were exploratory and since some groups were relatively small, so that these results should be interpreted with caution. Across the three weekly visits, genuine-score distributions differed significantly between Visit 1 and Visits 2–3, whereas no significant difference was observed between Visits 2 and 3. The impostor-score distributions did not differ significantly across visits. As shown by the violin plots in Fig 13, the median genuine score remained high across all visits (1.00, 0.99, and 0.99 for Visits 1–3, respectively), compared with a median impostor score of 0.06 at each visit, substantial separation between the genuine and impostor distributions was retained. The ROC curves in Fig 12 nevertheless indicated a measurable session effect, with AUC values of 0.97, 0.94, and 0.92 for Visits 1–3, respectively. These findings support three- week repeatability in the conditions tested here: despite the session-related shift occurring primarily between the first and subsequent visits, the genuine scores remained substantially higher than the impostor scores across all three visits. Longer-term longitudinal studies are needed to further characterize permanence.

In terms of age, there was a small but significant difference in genuine scores (driven by Group 1 vs. Group 3), whereas the impostor comparisons were not statistically significant after Bonferroni correction, indicating little evidence for strong age-related effects. In terms of smoking status, the genuine scores were similar between smokers and non-smokers, but the impostor scores were slightly higher among smokers, the only comparison that remained significant after correction.

User-specific or adaptive thresholding is an established approach in biometric verification and could be incorporated into future OCAV implementations to account for inter-user score variability [29]. The two thresholding strategies implemented here reflect different implementation assumptions. A global threshold is simpler to deploy and scale because the same decision boundary is applied to all users, but it may not account for subject-specific differences in oral acoustic variability. Participant-specific thresholds can partially account for individual score distributions and may improve accuracy, but they require sufficient enrollment data and may reduce generalizability if optimized too closely to the enrollment set. Participant- Participant-specific thresholding affects the decision boundary applied after enrollment and does not in and of itself limit OCAV universality. In this study, the participant-specific thresholds improved single-trial accuracy by about 2% compared to the global threshold. Importantly, these participant-specific results should be interpreted as an upper-bound feasibility estimate under the present protocol, whereas the global-threshold result may better reflect a simpler scalable implementation.

The OCAV system shares conceptual similarities with other excitation-response biometric modalities. For example, in speaker verification, airflow-driven vibration at the larynx provides the excitation, whereas the vocal tract, especially the oral and related cavities, acts like an acoustic filter that shapes the sound spectrum. Its resonances (formants) depend on the tract’s anatomy and geometry. These anatomical differences are one of the key reasons why voice has person-specific information and is widely leveraged in speaker verification research [30]. Ear-canal acoustic biometrics inject controlled acoustic signals into the ear canal and characterize the reflected response, leveraging the anatomical stability of the auditory canal [31]. This oral-cavity acoustic approach has several notable advantages over other biometric approaches. Anatomy-driven acoustics have been explored in the ear canal and showed person-specific impulse responses [10,11]. Speaker verification relies on speech and is sensitive to noise and channel mismatch [30,32]. Camera-based biometrics such as face and iris recognition require a clear unobstructed view and consistent lighting [33]. Fingerprint systems typically need finger contact with a clean sensor and clear ridge detail for best results [34]. The OCAV differs from most of these methods by using active sensing, where a brief acoustic audio signal is emitted when a pressure sensor detects inhalation, and the returning acoustic reflections are recorded by a microphone. As a result, the OCAV does not depend on speech input, camera input, or fingerprint capture quality. Under controlled conditions, our test-set AUC (0.942) indicated genuine/impostor separability consistent with our working assumption that anatomic acoustics can encode identity. Direct, head-to-head benchmarking with face/fingerprint/voice was beyond the scope of this study primarily because devices and protocols differ. For this reason, we interpret these findings as feasibility evidence for a complementary, low-effort verification modality. Biometric traits are typically evaluated according to criteria such as universality, distinctiveness, permanence, and resistance to circumvention [1,2]. In the current controlled study, we demonstrated distinctiveness (genuine-impostor separability) and short-term reliability (multi-session stability). Broader validation of large-scale universality, long-term permanence, liveness, spoof resistance, and any future standardization of this biometric trait will require further independent studies.

This study focused on verification accuracy under controlled use. The prototype used here represents laboratory implementation. In practical use, the hygiene requirements would depend on the target device and use model. For personal-use devices such as inhalers or e-cigarettes, the sensing unit would be integrated into a single-user device or used with a personal mouthpiece. For shared-use devices such as breathalyzers, disposable or replaceable mouthpieces, and cleaning protocols would be required. These implementation measures were not evaluated in the current study and require future validation. Because sensing is proximal and inhalation-triggered, the OCAV may be less sensitive to simple audio replay than speech-based methods. However, adversarial testing (e.g., timed replay, mechanical fixtures, or tamper attempts) could not be carried out and will be addressed in future work.

The OCAV technology has significant potential for integration into existing systems to enhance security and public safety. For instance, underage vaping remains common among adolescents (e.g., around 6% of all U.S. middle and high school students reported e‑cigarette use in 2024 [35]). Embedded within e‑cigarettes, the system could deter under-age use. When combined with breath-alcohol testing, mouth-specific verification could reduce cheating, such as having another person blow into the device. This aligns with emerging regulations in the U.S. and E.U. ADAS regulations that require in-vehicle alcohol-interlock systems. An oral-cavity-scanning device could thus enhance road safety by reducing alcohol-related accidents [36,37].

Strengths and limitations

The OCAV involves a brief interaction that generates an inhalation-triggered acoustic signal. Multi-session sampling per participant enabled assessment of within-person stability across visits. Subgroup analyses were conducted a-priori (age and smoking status) and the data were nearly balanced across groups, supporting fair comparisons. Genuine-impostor evaluations used randomized imposters drawn from the cohort, minimizing selection bias and improving the interpretability of the verification outcomes. From a feature-representation perspective, dimensionality reduction methods such as PCA or autoencoders were not applied in the present study because the feature set was computationally manageable and retained direct correspondence with interpretable acoustic-response and signal-quality descriptors. Future optimization should evaluate whether reduced feature representations can preserve performance while improving efficiency. The limitations include a single site, controlled conditions, and the fact that there was only one hardware prototype. Of the 108 enrolled, the data from 99 participants were analyzed after prespecified exclusions. We did not test robustness to background noise, posture, device variation, or long-term drift, and we did not perform replay/spoofing tests. The other limitations relate to the oral and inhalation-dependent nature of the measurement. Variability in inhalation force, flow, mouthpiece seal, tongue position, saliva, or moisture accumulation may have affected the acoustic response and could increase the false rejection rates outside the laboratory setting. Moisture condensation or saliva accumulation within the mouthpiece or acoustic channel could alter resonance characteristics, dampen acoustic reflections, and affect longitudinal reliability outside the laboratory. Hygiene requirements also depend on the intended use model, personal-use devices may use dedicated mouthpieces, whereas shared devices would require disposable or replaceable mouthpieces and cleaning protocols. Finally, spoofing risks, including artificial oral-cavity models or mechanically timed replay attempts, were not evaluated in this study. These issues require dedicated usability, hardware, hygiene, and adversarial testing before real-world deployment can be considered.

In this study, enrollment and verification were performed under controlled laboratory conditions. Therefore, device-to-device transferability was not evaluated. Use of separate devices at enrollment and verification could introduce differences related to speaker and microphone response, mouthpiece geometry, acoustic coupling, and environmental noise. Practical implementation would require standardized hardware, device calibration, and evaluation under realistic acoustic conditions. The participants were trained to use the device and to inhale in a relatively uniform manner. Therefore, the present results may not fully reflect use by untrained users or by users with more variable inhalation patterns. In real-world settings, differences in inhalation force, flow, mouthpiece seal, or user technique may increase false rejection rates and affect acceptability. These effects should be quantified in future usability and field studies. We also observed visible wear in some of the 3D-printed mouthpieces after repeated attachment-detachment, which could have weakened the seal and may have contributed to small session effects, which were not directly tested. These factors limit generalizability, so that the results should be interpreted as feasibility under the tested conditions rather than a head-to-head benchmark against face, fingerprint, iris, or voice systems.

Conclusion

The OCAV, a biometric verification device activated during natural inhalation, can reliably verify user identity using low‑cost, commodity hardware. We obtained a single‑trial accuracy of 90.1% (EER ≈ 12.5%) and 95.2% accuracy when aggregating five consecutive samples. Together with the ROC analysis (AUC = 0.942), these results support the feasibility of oral acoustic reflections for user verification under the controlled conditions tested here. The verification device achieved these results in less than 1 sec.

The OCAV system embeds identity verification directly into a user’s natural inhalation process. Each inhalation automatically triggers an acoustic echo recording and on-line verification, requiring no further user actions. This seamless integration illustrates its potential to reduce unauthorized use when incorporated into devices such as e-cigarettes and medical inhalers.

Future work should include testing in noisier and less controlled environments, as well as longitudinal validation over months or years in broader demographic and clinical cohorts. Studies should include direct comparisons with established biometrics, formal spoof-resistance testing, and evaluation of optimized device-integrated prototypes for durability and consistent acoustic coupling. Overall, the findings point to the promise of the OCAV system’s unique combination of speed, convenience, and embedded biometric verification for applications in public health and personalized security.

Supporting information

S1 Appendix. Overview of data flow.

Provides a detailed description of the data collection, administrative exclusions, verification-trial pairing, signal-quality filtering, anomaly rejection, and final cohort composition corresponding to Fig 9.

(PDF)

pone.0359160.s001.pdf (262.2KB, pdf)

Acknowledgments

We would like to thank Omer Gross, a biomedical engineering student at Ben-Gurion University, for her support in conducting the experiments for this study. Her assistance in data collection was essential to the successful completion of the experimental phase. We appreciate her valuable contribution to this research.

Data Availability

All data necessary to replicate the findings of this study are publicly available in the Zenodo repository: https://doi.org/10.5281/zenodo.17085926. The repository includes the anonymized comparison-feature matrix, trained LightGBM model, genuine/impostor labels and verification scores, and scripts required to reproduce the reported performance metrics. The de-identified oral-acoustic recordings, including the participant profile recordings, are also publicly available in the repository.

Funding Statement

This study was supported by Echo-ID Ltd., which provided institutional funding to Ben-Gurion University of the Negev for the conduct of this research. Echo-ID Ltd. also provided support in the form of salaries for authors A.K., D.T., E.H., and R.R., and provided the OCAV device used in this study. The study was designed collaboratively by academic investigators and co-author collaborators. The funder did not have any additional role in the independent data analysis, decision to publish, or preparation of the manuscript beyond the involvement of the named authors as co-investigators. The specific roles of these authors are articulated in the ‘Author Contributions’ section.

References

  • 1.Shaheed K, Mao A, Qureshi I, Kumar M, Abbas Q, Ullah I, et al. A Systematic Review on Physiological-Based Biometric Recognition Systems: Current and Future Trends. Archives of Computational Methods in Engineering. 2021;28:4917–60. doi: 10.1007/s11831-021-09560-3 [DOI] [Google Scholar]
  • 2.Alrawili R, AlQahtani AAS, Khan MK. Comprehensive survey: Biometric user authentication application, evaluation, and discussion. Computers and Electrical Eng. 2024;119:109485. doi: 10.1016/j.compeleceng.2024.109485 [DOI] [Google Scholar]
  • 3.Wu Z, Evans N, Kinnunen T, Yamagishi J, Alegre F, Li H. Spoofing and countermeasures for speaker verification: A survey. Speech Commun. 2015;66:130–53. doi: 10.1016/j.specom.2014.10.005 [DOI] [Google Scholar]
  • 4.Khazaleh OR, Khrais LA. An investigation into the reliability of speaker recognition schemes: analysing the impact of environmental factors utilising deep learning techniques. J Eng Appl Sci. 2024;71(1). doi: 10.1186/s44147-023-00351-0 [DOI] [Google Scholar]
  • 5.Al-Karawi KA, Mohammed DY. Using combined features to improve speaker verification in the face of limited reverberant data. Int J Speech Technol. 2023;26(3):789–99. doi: 10.1007/s10772-023-10048-7 [DOI] [Google Scholar]
  • 6.Cader MA, Banks AJ, Chandran J, Hu J, Wang M, Yin X. Fingerprint systems: sensors, image acquisition, interoperability and challenges. Sensors. 2023;23:6591. doi: 10.3390/S23146591 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Wang M, Deng W. Deep face recognition: A survey. Neurocomputing. 2021;429:215–44. doi: 10.1016/j.neucom.2020.10.081 [DOI] [Google Scholar]
  • 8.Parashar A, Parashar A, Abate AF, Shekhawat RS, Rida I. Real-time gait biometrics for surveillance applications: A review. Image Vis Comput. 2023;138:104784. doi: 10.1016/j.imavis.2023.104784 [DOI] [Google Scholar]
  • 9.Quinn GW, Grother P, Matey J. IREX IX part one, performance of iris recognition algorithms. Gaithersburg, MD. 2018. doi: 10.6028/NIST.IR.8207 [DOI] [Google Scholar]
  • 10.Gao Y, Wang W, Phoha VV, Sun W, Jin Z. EarEcho. Proc ACM Interact Mob Wearable Ubiquitous Technol. 2019;3:1–24. doi: 10.1145/3351239 [DOI] [Google Scholar]
  • 11.Sun X, Chen J, He K, He Z, Du R, Feng Y. SCR-Auth: Secure Call Receiver Authentication on Smartphones Using Outer Ear Echoes. 2024;1–13.
  • 12.Yang W, Wang S, Sahri NM, Karie NM, Ahmed M, Valli C. Biometrics for Internet-of-Things Security: A Review. Sensors (Basel). 2021;21(18):6163. doi: 10.3390/s21186163 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Awad AI, Babu A, Barka E, Shuaib K. AI-powered biometrics for Internet of Things security: A review and future vision. J Inf Security Appl. 2024;82:103748. doi: 10.1016/j.jisa.2024.103748 [DOI] [Google Scholar]
  • 14.Essink HM, Knops A, Liqui Lung AMA, van der Meulen CN, Wouters NL, van der Molen AJ, et al. Real-Time Person Identification in a Hospital Setting: A Systematic Review. Sensors (Basel). 2020;20(14):3937. doi: 10.3390/s20143937 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Workie AB. The Role of Biometrics in Improving Patient Identification and Safety in Healthcare. 2023;11:1–2. doi: 10.19080/BBOAJ.2023.11.555806 [DOI] [Google Scholar]
  • 16.Bertrand A, Diaz MC, Hair EC, Schillo BA. Easy access: identification verification and shipping methods used by online vape shops. Tob Control. 2025;34(2):259–62. doi: 10.1136/tc-2023-058303 [DOI] [PubMed] [Google Scholar]
  • 17.Wochinger K. State of the practice of alcohol ignition interlock programs. Washington, DC. 2023. [Google Scholar]
  • 18.Chougule SV. Analyzing Vocal Tract Parameters of Speech. 2021. p. 369–76. doi: 10.1007/978-981-15-8391-9_27 [DOI] [Google Scholar]
  • 19.Fant G. The relations between area functions and the acoustic signal. Phonetica. 1980;37(1–2):55–86. doi: 10.1159/000259983 [DOI] [PubMed] [Google Scholar]
  • 20.Welcome to LightGBM’s documentation! LightGBM 4.5.0.99 documentation. https://lightgbm.readthedocs.io/en/latest/index.html Accessed 2024 September 4. [Google Scholar]
  • 21.Ke G, Meng Q, Finley T, Wang T, Chen W, Ma W. LightGBM: A highly efficient gradient boosting decision tree. Advances in Neural Information Processing Systems. 2017;3147–55.
  • 22.Machado MR, Karray S, de Sousa IT. LightGBM: an Effective Decision Tree Gradient Boosting Method to Predict Customer Loyalty in the Finance Industry. In: 2019 14th International Conference on Computer Science & Education (ICCSE), 2019. 1111–6. 10.1109/iccse.2019.8845529 [DOI]
  • 23.Harris CR, Millman KJ, van der Walt SJ, Gommers R, Virtanen P, Cournapeau D, et al. Array programming with NumPy. Nature. 2020;585(7825):357–62. doi: 10.1038/s41586-020-2649-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.McKinney W. Data Structures for Statistical Computing in Python. In: Proceedings of the Python in Science Conference, 2010. 56–61. 10.25080/majora-92bf1922-00a [DOI]
  • 25.Virtanen P, Gommers R, Oliphant TE, Haberland M, Reddy T, Cournapeau D, et al. SciPy 1.0: fundamental algorithms for scientific computing in Python. Nature Methods. 2020;17(3):261–72. doi: 10.1038/s41592-019-0686-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Pedregosa F, Michel V, Grisel OL, Blondel M, Prettenhofer P, Weiss R. Scikit-learn: Machine Learning in Python. Journal of Machine Learning Research. 2011;12:2825–30. [Google Scholar]
  • 27.Hunter JD. Matplotlib: A 2D graphics environment. Comput Sci Eng. 2007;9:90–5. doi: 10.1109/MCSE.2007.55 [DOI] [Google Scholar]
  • 28.Waskom M. seaborn: statistical data visualization. J Open Source Softw. 2021;6(60):3021. doi: 10.21105/joss.03021 [DOI] [Google Scholar]
  • 29.Jain AK, Ross A. Learning user-specific parameters in a multibiometric system. In: Proceedings. International Conference on Image Processing. I-57-I–60. 10.1109/icip.2002.1037958 [DOI]
  • 30.Kinnunen T, Li H. An overview of text-independent speaker recognition: From features to supervectors. Speech Communication. 2010;52(1):12–40. doi: 10.1016/j.specom.2009.08.009 [DOI] [Google Scholar]
  • 31.Mahto S, Arakawa T, Koshinak T. Ear Acoustic Biometrics Using Inaudible Signals and Its Application to Continuous User Authentication. In: 2018 26th European Signal Processing Conference (EUSIPCO), 2018. 1407–11. 10.23919/eusipco.2018.8553015 [DOI]
  • 32.Joshi S, Dua M. Noise robust automatic speaker verification systems: review and analysis. Telecommun Syst. 2024;87:845–86. doi: 10.1007/s11235-024-01212-8 [DOI] [Google Scholar]
  • 33.Grother P, Ngan M, Hanaoka K. Face Recognition Vendor Test (FRVT) Part 2. Gaithersburg, MD: National Institute of Standards and Technology. 2019. doi: 10.6028/NIST.IR.8271 [DOI] [Google Scholar]
  • 34.Fernandez‐Saavedra B, Sanchez‐Reillo R, Ros‐Gomez R, Liu‐Jimenez J. Small fingerprint scanners used in mobile devices: the impact on biometric performance. IET Biometrics. 2016;5(1):28–36. doi: 10.1049/iet-bmt.2015.0018 [DOI] [Google Scholar]
  • 35.Jamal A, Park-Lee E, Birdsey J, West A, Cornelius M, Cooper MR. Tobacco product use among middle and high school students — National Youth Tobacco Survey, United States, 2024. MMWR Morb Mortal Wkly Rep. 2024;73:917–24. doi: 10.15585/mmwr.mm7341a2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.National Highway Traffic Safety Administration. Advanced Impaired Driving Prevention Technology. National Highway Traffic Safety Administration. 2024. [Google Scholar]
  • 37.European Commission. Commission Delegated Regulation (EU) 2021/1243 of 19 April 2021 supplementing Regulation (EU) 2019/2144 concerning the alcohol interlock installation facilitation in motor vehicles and amending Annex II to that Regulation. European Commission. 2021. p. 11–5. [Google Scholar]

Decision Letter 0

Amit Krishan Kumar

16 Jan 2026

Dear Dr. Kam,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

Please submit your revised manuscript by Mar 02 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

  • A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

We look forward to receiving your revised manuscript.

Kind regards,

Kumar, PhD

Academic Editor

PLOS One

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1.Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Please note that PLOS One has specific guidelines on code sharing for submissions in which author-generated code underpins the findings in the manuscript. In these cases, we expect all author-generated code to be made available without restrictions upon publication of the work. Please review our guidelines at https://journals.plos.org/plosone/s/materials-and-software-sharing#loc-sharing-code and ensure that your code is shared in a way that follows best practice and facilitates reproducibility and reuse.

3. Thank you for stating the following in the Competing Interests section:

“I have read the journal's policy and the authors of this manuscript have the following competing interests: Echo-ID Ltd. provided institutional support by funding the university’s conduct of this research. Amit Kam, Daniel Tubiana, Eran Hochstater and Roi Ram are employees of Echo-ID Ltd. This affiliation does not alter our adherence to PLOS ONE policies on sharing data and materials.”

We note that one or more of the authors are employed by a commercial company: name of commercial company.

1. Please provide an amended Funding Statement declaring this commercial affiliation, as well as a statement regarding the Role of Funders in your study. If the funding organization did not play a role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript and only provided financial support in the form of authors' salaries and/or research materials, please review your statements relating to the author contributions, and ensure you have specifically and accurately indicated the role(s) that these authors had in your study. You can update author roles in the Author Contributions section of the online submission form.

Please also include the following statement within your amended Funding Statement.

“The funder provided support in the form of salaries for authors [insert relevant initials], but did not have any additional role in the study design, data collection and analysis, decision to publish, or preparation of the manuscript. The specific roles of these authors are articulated in the ‘author contributions’ section.”

If your commercial affiliation did play a role in your study, please state and explain this role within your updated Funding Statement.

2. Please also provide an updated Competing Interests Statement declaring this commercial affiliation along with any other relevant declarations relating to employment, consultancy, patents, products in development, or marketed products, etc.

Within your Competing Interests Statement, please confirm that this commercial affiliation does not alter your adherence to all PLOS ONE policies on sharing data and materials by including the following statement: "This does not alter our adherence to  PLOS ONE policies on sharing data and materials.” (as detailed online in our guide for authors http://journals.plos.org/plosone/s/competing-interests) . If this adherence statement is not accurate and  there are restrictions on sharing of data and/or materials, please state these. Please note that we cannot proceed with consideration of your article until this information has been declared.

Please include both an updated Funding Statement and Competing Interests Statement in your cover letter. We will change the online submission form on your behalf.

4. We note that you have indicated that there are restrictions to data sharing for this study. PLOS only allows data to be available upon request if there are legal or ethical restrictions on sharing data publicly. For more information on unacceptable data access restrictions, please see http://journals.plos.org/plosone/s/data-availability#loc-unacceptable-data-access-restrictions.

Before we proceed with your manuscript, please address the following prompts:

a) If there are ethical or legal restrictions on sharing a de-identified data set, please explain them in detail (e.g., data contain potentially identifying or sensitive patient information, data are owned by a third-party organization, etc.) and who has imposed them (e.g., a Research Ethics Committee or Institutional Review Board, etc.). Please also provide contact information for a data access committee, ethics committee, or other institutional body to which data requests may be sent.

b) If there are no restrictions, please upload the minimal anonymized data set necessary to replicate your study findings to a stable, public repository and provide us with the relevant URLs, DOIs, or accession numbers. For a list of recommended repositories, please see

https://journals.plos.org/plosone/s/recommended-repositories. You also have the option of uploading the data as Supporting Information files, but we would recommend depositing data directly to a data repository if possible.

We will update your Data Availability statement on your behalf to reflect the information you provide.

5. When completing the data availability statement of the submission form, you indicated that you will make your data available on acceptance. We strongly recommend all authors decide on a data sharing plan before acceptance, as the process can be lengthy and hold up publication timelines. Please note that, though access restrictions are acceptable now, your entire data will need to be made freely accessible if your manuscript is accepted for publication. This policy applies to all data except where public deposition would breach compliance with the protocol approved by your research ethics board. If you are unable to adhere to our open data policy, please kindly revise your statement to explain your reasoning and we will seek the editor's input on an exemption. Please be assured that, once you have provided your new statement, the assessment of your exemption will not hold up the peer review process.

6. We notice that your supplementary figures are uploaded with the file type 'Figure'. Please amend the file type to 'Supporting Information'. Please ensure that each Supporting Information file has a legend listed in the manuscript after the references list.

Additional Editor Comments:

The authors are encouraged to carefully consider and respond to all reviewer comments in a comprehensive and balanced manner to strengthen the overall quality of the manuscript.

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

Reviewer #1: Partly

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: No

Reviewer #2: No

**********

3. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

Reviewer #2: Yes

**********

Reviewer #1: • A biometric characteristic is related to a human physical or behavioral characteristic, while acoustic reflections are the response of the human body to some external factor.

• This research is based on an artificial setting in which sound waves are transmitted in the oral cavity, and the acoustic response is captured and characterized for verification purposes. It is evident that the raw data collection setup has limited acceptability among users and is also susceptible to serious hygiene issues.

• There should be debate among experts before employing this strategy as a biometric trait. According to the authors, this has never been used as a biometric trait in past research works.

• As there is no prior literature available for this biometric trait, the comparison of this trait with the existing physical and behavioral biometric traits, like finger-vein, face shape, gait, etc., is supposed to be part of the literature. So that the experts may decide whether oral acoustic qualifies as a biometric trait or not.

• To facilitate the experts, for the biometric trait claimed in this manuscript, the degree of the qualities a biometric trait has, like acceptability, universality, uniqueness, reliability, liveliness, hard to counterfeit, etc. are to be reported through some lab or social experiment for which data is collected from common people.

• If some international biometric standardization organization approves oral acoustic as a valid biometric trait, this manuscript may be accepted for publication after the standard review process.

• The specification for hardware resources and software employed is to be mentioned in detail. The computing machine capability and the libraries, toolboxes, and functions employed in experimental simulations are to be mentioned along with the parameters/ hyperparameters details for facilitating researchers interested in confirmation of the reported results and performing comparative analysis.

Reviewer #2: Manuscript is interesting and following points should be considered during revision.

1) Classical biometric traits are inherently linked to stable human physiological or behavioral characteristics. In contrast, acoustic reflections primarily represent the body’s response to externally injected stimuli, which raises questions about their classification as a true biometric attribute.

2) The proposed methodology relies on an artificial acquisition setup where sound waves are actively introduced into the oral cavity and the resulting acoustic response is analyzed for identity verification. Such a data acquisition process may face significant challenges in terms of user comfort, practical acceptability, and hygiene, particularly in real-world deployment scenarios.

3) Given that the authors claim novelty in introducing oral acoustic response as a biometric modality, a broader discussion within the biometric research community appears necessary before considering its adoption. To the best of the reviewer’s knowledge, this modality has not been formally established or validated as a biometric trait in prior studies.

4) The manuscript should provide comprehensive details of the experimental setup, including hardware specifications and software resources. Information regarding the computing platform, employed libraries or toolboxes, and all relevant parameters and hyperparameters used in simulations should be explicitly stated to ensure reproducibility and facilitate comparative studies by future researchers.

5) To support the proposed claim, an evaluation of standard biometric properties such as universality, acceptability, uniqueness, permanence, reliability, liveness detection, and resistance to spoofing should be conducted. Ideally, these properties should be quantified through controlled laboratory studies or socially representative experiments involving data collected from a diverse population.

6) The authors should consider referencing prior studies on respiratory and airway acoustic/impedance modeling, where anatomical and biomechanical properties of the oral–respiratory system were shown to produce distinctive and repeatable acoustic responses. In particular, respiratory-signal-based modeling approaches used for inhalation impedance estimation and respiratory pattern analysis could provide additional context supporting the uniqueness and stability of oral acoustic reflections used for biometric verification. I suggest authors cite this: 'Spirometer and sEMG respiratory patterns for clinical decision support system'. ( doi: 10.1109/I2MTC53148.2023.10175925 )

7) Since there is no established literature on oral acoustics as a biometric modality, the manuscript would benefit from a comparative discussion with well-known physical and behavioral biometrics (e.g., fingerprint, finger-vein, facial structure, gait). Such a comparison could help clarify whether oral acoustic characteristics meet the fundamental criteria required of a biometric trait.

8) Acceptance of oral acoustic response as a valid biometric modality would be significantly strengthened if it were endorsed or standardized by a recognized international biometric standardization body. Without such validation, the contribution remains preliminary.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #2: No

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

Attachment

Submitted filename: CommentsToAuthors.docx

pone.0359160.s002.docx (14.6KB, docx)

Decision Letter 1

Diego Forero

5 May 2026

Dear Dr. Kam,

Please submit your revised manuscript by Jun 19 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

  • A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only  the individual author can complete the verification step; PLOS staff cannot  verify ORCID iDs on behalf of authors.

We look forward to receiving your revised manuscript.

Kind regards,

Diego A. Forero, MD; PhD

Academic Editor

PLOS One

Journal Requirements :

If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise.

Editorial Office Comments :

Please disregard the reports of Reviewer #2. As discussed with the Academic Editor, there is no need to respond to this reviewer.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

Reviewer #1: (No Response)

Reviewer #2: (No Response)

Reviewer #3: (No Response)

**********

2. Is the manuscript technically sound, and do the data support the conclusions??>

Reviewer #1: Partly

Reviewer #2: No

Reviewer #3: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: N/A

Reviewer #2: No

Reviewer #3: No

**********

4. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: No

Reviewer #2: No

Reviewer #3: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

Reviewer #2: No

Reviewer #3: Yes

**********

Reviewer #1: The authors present a novel biometric verification system based on oral cavity acoustics (OCAV).

The authors have largely ignored the first-round comment regarding approval of this biometric trait by an international biometric standardization organization, and then they should proceed with the review process.

However, these observations are to be communicated to the authors.

• The abstract highlights novelty but remains largely descriptive. Please sharpen the novelty claim by explicitly contrasting OCAV with ear-canal and voice biometrics in terms of anatomical stability, spoofing resilience, and deployment feasibility.

• The authors have combined the Introduction section with the related literature section. It is advised to separate both sections. A tabular summary will enhance the readability of the related literature section, listing the methodology employed, main performance metrics reported, and the shortcomings.

• The claimed contributions of the research work are to be mentioned at the end of the related literature section in bulleted form.

• However, the authors have mentioned that sterilization has been performed periodically to handle hygiene issues. The main concern is still there, that is, the serious hygiene issue. As the authors have mentioned, the OCAV profile is generated and recorded when an authorized / unauthorized user inhales using the OCAV system-installed inhaler. Therefore, in real-life environments, there are severe hygiene issues.

• As there will be separate devices used during the capturing of the subject’s OCAV signature at the time of enrollment (in the lab) and at the time of verification/identification (noisy real-life environment). There are chances of variations in the captured OCAV signatures at the enrollment and verification stages. This issue is to be discussed, and an explanation is required to handle it.

• The authors have mentioned that during the pre-training session, the participating subjects were trained regarding the proper usage of the inhaler. Hence, the margin of error and rejection rate for genuine users are expected to be higher when implemented in real life. Further, this uniform inhalation requirement results in limited acceptability, universality, and reliability.

• The approval letter (approval no. 467-3) is required to be presented in the Appendix.

• The 342-dimensional feature vector is described but not justified. Please explain why this dimensionality was chosen and whether dimensionality reduction (e.g., PCA, autoencoders) was considered to improve efficiency.

• The function of the Isolation Forest model requires explanation when employed to label the outlier feature vectors.

• The LightGBM classifier is trained on an in-house dataset. Clarify whether cross-validation was used and discuss risks of overfitting given the relatively small participant pool. This will reassure readers about methodological rigor.

• The authors have reported both global and participant-specific thresholds. Please expand the discussion of implications for deployment, particularly the trade-off between generalizability and personalization, and scalability concerns.

• These figures have the following concerns:

o Fig. 2 (D) schematic diagram: needs clearer labeling of components and signal flow.

o Fig. 5 transfer functions: there is only one transmitted and reflected signal, while the caption states ‘Transfer functions of two different participants’. No transfer function h(t) is defined in this figure in some mathematical equation form. This figure is to be revised.

o ROC and violin plots (Figs. 10–17): captions and text should explain what the differences mean, not just present curves.

• The discussion underplays limitations. Please add explicit mention of inhalation variability, spoofing risks (e.g., artificial oral cavities), and hygiene challenges, along with preliminary mitigation strategies.

• The conclusion section must justify the claimed contributions by referring to the presented experimental results in the form of performance metrics or ROC graphs.

• The conclusion could be enriched by suggesting next steps: testing in noisy environments, integration into commercial devices, and longitudinal studies to assess stability over months/years. This would give the paper a stronger translational impact.

Reviewer #2: 1) Wen authors say "Biometric verification methods, such as face and fingerprint verification, are commonly used in smartphones, security systems, and medical devices." This statement is generic background knowledge and contributes almost no technical information. The mention of medical devices is vague; biometric authentication is not yet widely standardized in clinical devices, so this claim should be clarified or supported. No connection is established with acoustic biometrics or physiological acoustics, which is the actual topic.

2) Anti-spoofing research in face and fingerprint recognition is highly mature. Go get you research right first before making any claims.

3) Readers mainly look at abstract to know authors' intelligent level. “Current systems are not readily adaptable to biometric verification in oral substance-exchange devices such as inhalers, breathalyzers, and nicotine devices.” where is proof of this statement. It ignores existing voice biometrics, which already operate through the oral cavity. There is major motivational gap.

4) Missing details include:

a)Acoustic signal properties: frequency range, waveform type (chirp, sweep, impulse), sampling rate

b) Hardware configuration: microphone placement, speaker location

c) Feature extraction: spectral features?, resonant modes?, transfer function estimation?

d) Classifier: thresholding, machine learning model, template matching

e) Noise handling: saliva, breathing, tongue motion

f) Repeatability issues: mouth opening variability

Include ALL above details. Without it the work is useless.

5) Dataset description is minimal: gender distribution missing, ethnic diversity missing, dental conditions not reported,

orthodontics / dentures ignored

Oral cavity acoustics are heavily affected by: tongue position, saliva volume, jaw angle, dental structure

Report ALL above to make this article atleast useful

6) Give thorough information on trials. a) What defines a trial?; b) How are impostor trials generated?

7) Are impostors cross-subject comparisons or simulated attacks? Give a paragraph on this

8) Give MATHEMATICALLY and in TEXTS how session variability analyzed?

9) Show cross validation and ablation of it. One paragraph.

10) A thorough discussion and MATHEMATICAL MODEL of how environmental conditions were controlled?

11) Biometric systems should report: False Acceptance Rate (FAR), False Rejection Rate (FRR), Equal Error Rate (EER),

ROC or DET curves

12) There is No confidence intervals, No baseline comparisons, No statistical significance, No latency or computation cost shown.

13) Table 1 is scientifically wrong.

14) Have the courtesy to acknowledge the use of AI tools. Extremely large portions of the text show uniform phrasing patterns and stylistic structures that are commonly associated with generative AI-assisted writing. However, the manuscript does not contain any disclosure regarding the use of such tools. The authors are encouraged to clarify this aspect and include a formal statement on AI-assisted manuscript preparation. This also raises concerns on originality of the research.

15) “Potential applications include health monitoring with inhalers, alcohol testing with breathalyzers, and enforcement of nicotine-use restrictions.” This claims are speculative

16) “These capabilities can support public health and safety efforts, for example limiting youth access to nicotine products and monitoring impaired driving.” This is policy speculation rather than scientific contribution. It also introduces ethical and regulatory implications without discussing: privacy concerns, biometric storage security, spoofing resistance.

17) The work relies heavily on generic statements, provides minimal methodological detail and includes speculative application claims.

18) The authors’ response does not adequately satisfy the journal’s requirements regarding code availability and reproducibility.

While the authors state that they will release the trained LightGBM model, feature matrices, labels, and evaluation scripts, they explicitly acknowledge that the proprietary feature-extraction development framework and original model training procedure will not be shared. This omission is critical because the feature extraction pipeline constitutes the core methodological contribution of the work. Without access to the feature generation process, the community cannot reproduce the model inputs from the raw acoustic recordings.

Providing a trained model and precomputed feature matrices does not constitute reproducibility. At best, it allows partial verification of reported metrics under fixed inputs. It does not allow independent reconstruction of the analysis pipeline, nor does it allow verification that the reported features genuinely originate from the raw acoustic signals described in the manuscript.

In biometric verification systems, the feature extraction stage typically defines the discriminative representation of the biometric signal. Therefore, withholding the feature extraction framework effectively prevents: a) Independent validation of the acoustic signal processing pipeline, b) Reproduction of the 242-dimensional feature representation, c) Verification that the features correspond to physiologically meaningful acoustic characteristics, d) Re-training or stress-testing of the method under different experimental conditions

The statement that “retraining is not required to reproduce the published results” is not sufficient. Reproducibility requires that an independent researcher can regenerate the features, retrain the model, and reproduce the reported results starting from the raw data. The current proposal does not enable this.

Furthermore, the justification that the framework is proprietary does not override the journal’s reproducibility requirements. If the core algorithm cannot be released, the authors must either a) Provide the complete feature extraction code and training pipeline necessary to reproduce the results from raw recordings, or b) Provide a detailed, implementable description of the feature extraction process sufficient for independent reconstruction.

Without one of these options, the manuscript fails to meet the journal’s standards for transparency and reproducibility.

Unless the authors provide access to the full feature extraction pipeline and model training procedure, the manuscript does not comply with the journal’s code-sharing policy. In its current form, the study cannot be independently reproduced and therefore should not proceed to publication.

19) The Data Availability Statement should be revised to ensure that all primary data, including the raw acoustic recordings, are publicly accessible without restriction at the time of publication. If this cannot be done, the manuscript does not satisfy the journal’s data availability requirements.

20) The authors indicate that only the derived 242-dimensional feature matrix, trained LightGBM model, and evaluation scripts will be publicly deposited, while the raw acoustic recordings will only be available upon request. This is problematic for several reasons.

First, the raw recordings constitute the primary experimental data from which all results are derived. Restricting access to these data prevents independent verification of the signal processing steps and makes it impossible to confirm that the released feature matrix accurately reflects the underlying recordings.

Second, the claim that the raw recordings are “not required to reproduce the published results” is not acceptable. Reproducibility requires that independent researchers can reconstruct the entire analytical pipeline starting from the original data, not merely reproduce metrics from precomputed features supplied by the authors.

Third, providing data only “upon reasonable request” introduces a gatekeeping mechanism that conflicts with open-data principles and the journal’s requirement that materials necessary to replicate the findings be made publicly available without restriction.

Unless there are clear and justified ethical or legal constraints—which have not been demonstrated here—the raw de-identified recordings should be deposited in the same public repository as the other materials

21) All figures representation are pathetic. The fonts size, font type do not match. Most of it looks copied from other sources. Moreover, the authors' do not provide caption, maybe because they do not know what the diagram represents, because if they had overlooked, then 1 or 2 figures will have captions missing. In this case all figures are without captions. The quality of figures are bad and seem like snapshot from other sources. This is evident through varying parameters in figures. Authors also used white arrows. Authors chut make figures better.

22) The current experiments rely on a laboratory prototype and controlled acquisition conditions, which do not replicate the operational environment of the proposed applications (e.g., inhalers, breathalyzers, or nicotine devices). In such real-world settings, factors such as airflow, saliva presence, device geometry, user posture, and hygiene constraints can significantly alter the acoustic response of the oral cavity. Simply stating that the sensing unit could be embedded in personal oral devices does not resolve these concerns, as no experiments or simulations are presented to demonstrate robustness under such conditions. The manuscript should therefore acknowledge this limitation explicitly and avoid implying practical readiness for these applications without supporting experimental validation.

23) The study does not present empirical evaluation of universality, long-term permanence, liveness robustness, resistance to spoofing, or user acceptability, all of which are central criteria in determining whether a physiological signal can realistically function as a biometric trait. Simply discussing these criteria in the Discussion section does not substitute for experimental evidence.

24) The claim that oral acoustic response has not previously been used as a biometric identifier, a more rigorous comparative positioning against established biometric modalities is necessary. Without such evaluation, it is difficult to assess whether the proposed signal genuinely satisfies the foundational requirements expected of biometric traits.

25) At minimum, the manuscript should clearly frame the work as a preliminary feasibility study, avoid implying readiness as a biometric modality, and explicitly acknowledge that the majority of biometric validity criteria remain untested.

26) For proper reproducibility and comparative analysis, the manuscript should explicitly report:

a) Hardware specifications (CPU/GPU model, RAM, operating system)

b) Exact software versions (Python, libraries, toolkits)

c) Complete model configuration, including all LightGBM and Isolation Forest hyperparameters

d) Training configuration (random seeds, data splits, number of iterations, stopping criteria)

e) Any preprocessing or normalization steps applied before feature input

Without these details, it remains difficult for other researchers to replicate the reported results or perform meaningful comparisons. The Methods section should therefore provide a fully specified experimental configuration rather than a general description of the environment.

26) Show feature extraction block diagram clearly with all details.

27) Provide algorithm and pseudocode of the approach

28) The proposed method treats the acoustic signal as a generic feature vector for a gradient boosting classifier, which is an oversimplification of the underlying physical process. The oral cavity should be modeled explicitly as an acoustic system. The authors should implement acoustic transfer function identification, estimating the impulse or frequency response between the transmitted signal and the received response. In addition, the acoustic field within the oral cavity should be analyzed through modal decomposition based on the Helmholtz equation, allowing the extraction of resonance modes that can serve as physically meaningful biometric signatures.

29) The current approach lacks a physically interpretable model linking the measured reflections to the geometry of the oral cavity. The problem should be formulated as an inverse acoustic scattering or acoustic tomography problem, where reflected signals are used to infer structural properties of the cavity. Furthermore, the authors should incorporate classical system identification techniques (e.g., ARMA or state-space acoustic modeling) to estimate stable dynamic representations of the oral cavity response rather than relying solely on engineered features.

30) The machine learning framework remains relatively shallow and does not incorporate the known physics governing acoustic propagation. The authors should consider physics-informed neural networks (PINNs) so that the learned representations satisfy the governing acoustic equations (e.g., Helmholtz constraints). Additionally, the mapping between the transmitted excitation and the measured response should be modeled using neural operator frameworks (such as Fourier Neural Operators or DeepONet), which are specifically designed to learn functional mappings between signals in physical systems.

31) The verification process is currently formulated as a standard classifier, which is not aligned with modern biometric verification paradigms. The authors should adopt contrastive or metric-learning approaches (e.g., triplet loss or InfoNCE) to learn identity embeddings from acoustic responses. In addition, the decision stage should be formulated within a Bayesian verification framework, where likelihood ratios are used to evaluate the hypotheses of genuine versus impostor identity, which is standard practice in rigorous biometric system design.

32) The feature representation strategy remains purely statistical and does not explore structural properties of the acoustic response. The resonance spectra and response patterns should be analyzed using topological data analysis (e.g., persistent homology) to extract invariant descriptors of resonance structure. Furthermore, if cavity structure or response geometry can be inferred, the authors should explore geometric or graph-based learning methods, which are more appropriate for representing complex anatomical or acoustic manifolds.

33) While the study is described as a feasibility investigation, the manuscript still proposes a new biometric modality, which requires at least preliminary empirical assessment of the fundamental biometric properties beyond distinctiveness and short-term reliability.

The current evaluation remains limited to a relatively small and homogeneous cohort under controlled laboratory conditions. Key biometric characteristics—such as universality across broader populations, permanence over longer time scales, liveness detection, and resistance to spoofing—are not experimentally examined, yet these properties are central to determining whether a physiological signal can function as a practical biometric trait.

Simply stating that these evaluations are outside the scope of the present study is not sufficient, particularly when the manuscript discusses potential deployment in security-sensitive applications. At minimum, the manuscript should clearly limit its claims to a preliminary feasibility demonstration, and explicitly acknowledge that the majority of standard biometric validation criteria remain untested and require dedicated investigation before the modality can be considered viable.

34) Authors used very old references in their manuscript, include at least 20 more references from year 2022 to 2026.

35) Why is Omer Gross removed from authorship if the personal did the major work. The acknowledgement raises a concern regarding authorship attribution. The authors state that Omer Gross “provided support in conducting the experiments” and that her “assistance in data collection was essential to the successful completion of the experimental phase.” This description suggests a substantial contribution to the experimental work and primary data acquisition, which typically qualifies as a significant research contribution.

According to widely accepted authorship guidelines (e.g., ICMJE and similar editorial standards), individuals who make substantial contributions to the acquisition of data or experimental execution should normally be considered for authorship, particularly when their role is described as essential to the completion of the study.

The authors should therefore clarify the exact nature and extent of Omer Gross’s contribution. If she indeed played a central role in conducting the experiments and collecting the primary dataset used in the study, her contribution appears to meet the threshold for authorship rather than acknowledgement.

The authors should either: a) Include Omer Gross as a co-author, with her contributions clearly stated, or b) Provide a clear explanation confirming that the contribution does not meet the journal’s authorship criteria and that she has agreed to be acknowledged instead.

Clarification is necessary to ensure compliance with proper authorship and contribution standards.

36) The conclusion overstates the practical readiness and comparative performance of the proposed system. The study was conducted under controlled laboratory conditions with a limited cohort, yet the text implies performance comparable to established biometric systems and readiness for deployment in real devices. Moreover, an EER of approximately 12.5% is relatively high for biometric verification, and the claim of strong resistance to spoofing is not supported by dedicated adversarial experiments. The conclusion should therefore be moderated to reflect that the study represents a preliminary feasibility evaluation, and avoid claims of comparability with standard biometrics or real-world applicability without further large-scale, longitudinal, and security-focused validation.

Reviewer #3: The authors have done a commendable job addressing several of the concerns raised in the previous review round. However, before the manuscript can be fully accepted for publication, there are critical methodological clarifications regarding the machine learning pipeline and the physical constraints of the hardware that must be explicitly addressed in the text.

1. Critical Methodological Ambiguity

In the "Classification Model" section, the authors state: "We trained the LightGBM classifier on a pre-existing in-house dataset of 20,000 comparison vectors...". It is imperative to explicitly clarify the demographic origin of this "in-house dataset." Specifically, the authors must state whether the subjects in this training dataset are entirely mutually exclusive from the 108 subjects used in the testing cohort. If there is any subject overlap between the pre-existing training set and the test set, this would introduce a substantial risk of data leakage and could materially inflate the reported AUC and accuracy estimates. Please add a sentence or paragraph explicitly defining the separation between the training and testing sets to assure the readers of the model's generalizability and statistical rigor.

2. Fluid Dynamics and Inhalation Variance

The system relies on a pressure drop during inhalation to trigger the acoustic chirp. Under controlled laboratory conditions, subjects were trained to breathe uniformly. However, in real-world applications (e.g., impaired individuals using breathalyzers, or patients with varying respiratory capacities), inhalation force and velocity will fluctuate significantly. Such variations could affect the measured acoustic transfer function and therefore the stability of verification performance in real-world use.

Did the training or testing protocols evaluate intra-subject variance across different inhalation intensities? If this variable was controlled or assumed constant, it must be explicitly acknowledged as a constraint in the "Strengths and limitations" section, as natural respiratory variance could affect the stability of the transfer function in field deployments.

3. Environmental Degradation of the Acoustic Channel

In the limitations section, the authors appropriately mention the mechanical wear of the 3D-printed mouthpieces. However, for a device handling oral substance-exchange, acoustic sensors are highly susceptible to micro-environmental changes.

Please add a brief acknowledgment in the limitations section regarding the potential impact of moisture condensation or saliva accumulation within the acoustic channel over time. These factors can alter the resonance and dampen the acoustic reflections, which would be important to consider for longitudinal reliability outside the laboratory.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #2: No

Reviewer #3: Yes:  Fabian León-Vargas

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

Attachment

Submitted filename: CommentsToAuthors.docx

pone.0359160.s004.docx (17.2KB, docx)
PLoS One. 2026 Sep 25;21(9):e0359160. doi: 10.1371/journal.pone.0359160.r004

Author response to Decision Letter 2


18 Jun 2026

All response to editor and reviewers are in the Response to Reviewers doc

Attachment

Submitted filename: Response_to_Reviewers_auresp_2.docx

pone.0359160.s007.docx (25.9KB, docx)

Decision Letter 2

Diego Forero

7 Jul 2026

Dear Dr. Kam,

Please submit your revised manuscript by Aug 21 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

  • A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only  the individual author can complete the verification step; PLOS staff cannot  verify ORCID iDs on behalf of authors.

We look forward to receiving your revised manuscript.

Kind regards,

Diego A. Forero, MD; PhD

Academic Editor

PLOS One

Journal Requirements:

If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise.

Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

Reviewer #1: All comments have been addressed

Reviewer #3: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions??>

Reviewer #1: Yes

Reviewer #3: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: Yes

Reviewer #3: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: No

Reviewer #3: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

Reviewer #3: Yes

**********

Reviewer #1: Comments to Authors:

In response to the previous round comments, the authors have made significant changes. These observations are made from the revised manuscript:

• The Authors stated that the study was a controlled feasibility study rather than a standardized or fully validated biometric modality.

• Enhancements have been made to the abstract and introduction, which include contrasts between OCAV and existing biometric approaches, and a comparative literature table.

• Bulleted contributions, ethics approval paperwork, and better labeling of figures have been added.

• Increased discussion of limitations (hygiene issues, inhalation variation, spoofing risk, device variation) has been added.

• Technical details have been explained, including the 342-dimensional feature vector, Isolation Forest role, LightGBM training/testing separating and thresholding strategies.

• The claimed contributions have been linked to the derived conclusions and set future directions.

These points of improvement are to be communicated to the authors.

1. The authors have included this sentence in the main contributions (Identify current limitations related to controlled acquisition, inhalation variability, device consistency, hygiene, and the need for future validation). This sentence should not be written in the main contributions but should be mentioned in the conclusion and discussion sections only.

2. The discussion from line number 398 to 414 of the revised manuscript gives the impression that the genuine scores vary between trial sessions. Hence, OCAV has low permanence. Permanence is a characteristic required for a human quality to be qualified as a biometric trait. Some justification for this should be included in the manuscript.

3. The authors should clarify that using participant-specific thresholds won’t affect the universality of the OCAV inversely.

4. The given reason for the dismissal of PCA/autoencoders as “not applicable because manageable” is convincing. If there is a better reason, for example, interpretability or reproducibility, then there will be more confidence in the feature set chosen.

5. The manuscript should be checked for English language mistakes employing some human language expert or specialized language software in consent with the authors.

Reviewer #3: Comments were properly addresed. The OCAV system represents an innovative approach to biometric verification, and this foundational study provides a solid and honest framework for future longitudinal and real-world validations.

I recommend the manuscript for acceptance in its current form.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #3: Yes:  Fabian León-Vargas

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

Attachment

Submitted filename: CommentsToAuthors.docx

pone.0359160.s006.docx (13.9KB, docx)

Decision Letter 3

Diego Forero

10 Sep 2026

Biometric verification using oral acoustic reflections

PONE-D-25-49343R3

Dear Dr. Kam,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Diego A. Forero, MD; PhD

Academic Editor

PLOS One

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

Reviewer #1: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions??>

Reviewer #1: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

**********

Reviewer #1: In response to the previous round comments, the authors have made significant changes. All the communicated observations have been addressed in the revised manuscript.

However, I still feel that it is required to perform longer span longitudinal study to evaluate the degree of OCAV permanence and other biometric characteristics. This point has already been acknowledged by the authors at line number 421 of the revised manuscript.

The manuscript has also been reviewed by human English language expert. Therefore, in my opinion, the manuscript may be accepted in the current form.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

**********

Attachment

Submitted filename: CommentsToAuthors.docx

pone.0359160.s008.docx (12.6KB, docx)

Acceptance letter

Diego Forero

PONE-D-25-49343R3

PLOS One

Dear Dr. Kam,

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team.

At this stage, our production department will prepare your paper for publication. This includes ensuring the following:

* All references, tables, and figures are properly cited

* All relevant supporting information is included in the manuscript submission,

* There are no issues that prevent the paper from being properly typeset

You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps.

Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing.

If we can help with anything else, please email us at customercare@plos.org.

Thank you for submitting your work to PLOS One and supporting open access.

Kind regards,

PLOS One Editorial Office Staff

on behalf of

Dr. Diego A. Forero

Academic Editor

PLOS One

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Appendix. Overview of data flow.

    Provides a detailed description of the data collection, administrative exclusions, verification-trial pairing, signal-quality filtering, anomaly rejection, and final cohort composition corresponding to Fig 9.

    (PDF)

    pone.0359160.s001.pdf (262.2KB, pdf)
    Attachment

    Submitted filename: CommentsToAuthors.docx

    pone.0359160.s002.docx (14.6KB, docx)
    Attachment

    Submitted filename: Response to reviewers.docx

    pone.0359160.s005.docx (29.3KB, docx)
    Attachment

    Submitted filename: CommentsToAuthors.docx

    pone.0359160.s004.docx (17.2KB, docx)
    Attachment

    Submitted filename: Response_to_Reviewers_auresp_2.docx

    pone.0359160.s007.docx (25.9KB, docx)
    Attachment

    Submitted filename: CommentsToAuthors.docx

    pone.0359160.s006.docx (13.9KB, docx)
    Attachment

    Submitted filename: Response_to_Reviewers_auresp_3.docx

    pone.0359160.s009.docx (21.3KB, docx)
    Attachment

    Submitted filename: CommentsToAuthors.docx

    pone.0359160.s008.docx (12.6KB, docx)

    Data Availability Statement

    All data necessary to replicate the findings of this study are publicly available in the Zenodo repository: https://doi.org/10.5281/zenodo.17085926. The repository includes the anonymized comparison-feature matrix, trained LightGBM model, genuine/impostor labels and verification scores, and scripts required to reproduce the reported performance metrics. The de-identified oral-acoustic recordings, including the participant profile recordings, are also publicly available in the repository.


    Articles from PLOS One are provided here courtesy of PLOS

    RESOURCES