Skip to main content
PLOS One logoLink to PLOS One
. 2026 Sep 28;21(9):e0358007. doi: 10.1371/journal.pone.0358007

Comparative study on the clinical effectiveness of low-concentration cyclosporine eye drops in patients with dry eye disease

Jae Hyun Kim 1, Hui Kyung Kim 1, Young-Joo Shin 2, Chul Young Choi 3, Hong Kyun Kim 4, Eunchul Kim 5, Jae Yong Kim 6, Ji Eun Lee 7, SunWoong Kim 8, Moonwon Hwang 9, Jong-Seok Song 10, Dong Hyun Kim 11, Jong Soo Lee 1,12,*
Editor: Kofi Asiedu13
PMCID: PMC13618915  PMID: 42804440

Abstract

Purpose

This study aimed to evaluate the efficacy and safety of low-concentration, nanoparticle-based cyclosporine eye drops (SCAI-001 0.01% and SCAI-001 0.02%) compared to those of the conventional Restasis® (cyclosporine 0.05%) emulsion for dry eye disease (DED).

Methods

In this multicenter, randomized, double-blind, Phase 2 trial, patients with DED were assigned to three groups: SCAI-001 0.01%, SCAI-001 0.02%, and Restasis. The primary efficacy endpoint was the change in tear volume after 12 weeks. Secondary efficacy endpoints included changes in tear volume at 4 and 8 weeks, corneal and conjunctival surface staining scores, tear film breakup time (TBUT), standard patient evaluation of eye dryness questionnaire score (SPEED), and ocular surface disease index (OSDI) at 4, 8, and 12 weeks.

Results

Tear volume increased in all groups at 12 weeks without intergroup differences. SCAI-001 0.01% and SCAI-001 0.02% achieved earlier improvements in tear volume at 4 weeks than that of Restasis, although no significant between-group difference was observed at any time point. Conjunctival surface scores improved in all groups at 4, 8, and 12 weeks, excluding 4 weeks of Restasis. Conjunctival staining improved to a greater extent with SCAI-001 0.01% than with Restasis at weeks 4 and 8. Corneal surface scores, TBUT, SPEED, and OSDI scores improved in all groups at 4, 8, and 12 weeks without intergroup differences.

Conclusions

Low-concentration cyclosporine (SCAI-001 0.01% and SCAI-001 0.02%) demonstrated efficacy and safety comparable to that of Restasis in improving DED measures.

Trial registration

ClinicalTrials.gov Identifier: NCT05733624.

Introduction

Dry eye disease (DED) is a multifactorial disease characterized by the loss of homeostasis of the tear film and ocular surface with symptoms such as ocular discomfort and blurred vision. Tear film instability and hyperosmolality cause ocular surface inflammation, leading to damage to the ocular surface [1]. It has a reported prevalence of approximately 5–50% in Asia while 5–30% in United States, Australia, and Europe [2,3]. Topical steroids are commonly used to manage inflammation of the ocular surface, but their prolonged use is restricted owing to side effects such as increased intraocular pressure, ocular infections, and cataracts [4,5].

Cyclosporine is widely recognized as an anti-inflammatory agent effective in treating DED. It achieves this by reducing the number of inflammatory cells, increasing the number of goblet cells, and increasing tear production [5]. Cyclosporine binds intracellular cyclophilin to form a complex that inhibits calcineurin phosphatase, thereby suppressing transcription of pro-inflammatory cytokines such as interleukin-2, a key driver of T-cell-mediated ocular surface inflammation in DED [6]. This immunomodulatory action reduces conjunctival lymphocyte infiltration and inflammatory cytokine expression while increasing goblet cell density [7]. It also restores tear production suppressed by inflammation through recovery of corneal nerve function which strengthens reflex arcs to stimulate tear secretion [8].

Cyclopsorine has lipophilic characteristics and low water-solubility, owing to its amino acid ring structure and strong intramolecular attraction. Regarding 0.05% micro-emulsion cyclosporine, (Restasis, Allergan Inc., Irvine, CA, USA), organic solvents are used to improve its water-solubility [9–11]. However, being an anionic emulsion, its bioavailability may be compromised when applied to the negative charged corneal surface [11]. To address this, a 0.1% cyclosporine cationic emulsion (I-Kervis, Santen SAS, Evry, France) utilizing cetalkonium chloride, a cationic surfactant, has been introduced [10,12]. Recently, 0.05% nano-emulsion cyclosporine (Cyclosporine N, Taejoon, Seoul, Korea) with reduced particle size and utilizing a self-nanoemulsifying drug delivery system has been developed and is being used in clinical practice [13].

Since the introduction of cyclosporine eye drops, studies have demonstrated improvements in tear volume, tear film breakup time, and corneal staining scores in patients with DED [11–17]. Even when compared to diquafosol, cyclosporine has shown excellent improvement in corneal staining [2,18,19]. However, the burning sensation and discomfort associated with the use of cyclosporine have been identified as factors that reduce treatment compliance. This discomfort arises because cyclosporine is almost completely insoluble in water, thus needing to be dissolved in an organic solvent and assisted by a surfactant [9,13,20]. Regarding Restasis, castor oil and polysorbate 80 are the main side effect-inducing additives [11,16,21], and in I-kervis, surfactants such as tyloxapol and poloxamer 188, were reported to induce pain on the ocular surface [22–24].

SCAI therapeutics (Daejeon, Republic of Korea) has developed a novel cyclosporine ophthalmic formulation, SCAI-001 eye drops, with lower cyclosporine concentration (0.01% and 0.02%) than conventional cyclosporine eye drop such as 0.05% cyclosporine (Restasis, Allergan Inc.) but with greater solubility and permeability only with a small amount of surfactant. To improve the poor solubility of cyclosporine, SCAI eye drops employ a proprietary technology called Molecular Associated Innovative Substance that generates nanosized molecular complexes as the dissolved raw materials pass through physically confined space. This allows for the creation of a transparent formulation and reduces the need for additives. This Phase 2 study aimed to evaluate the efficacy and safety of SCAI-001 eye drops (cyclosporine 0.01% and 0.02%) in DED treatment by comparing them with Restasis (cyclosporine 0.05%).

Participants and methods

Study design

This was a Phase 2, multicenter, randomized, double-blind, active-controlled trial conducted at 11 medical institutions to compare the efficacy and safety of SCAI-001 0.01% and 0.02% with Restasis 0.05% in patients with DED. Participants were prospectively recruited from 4 January 2023 to 15 May 2023 with different initiation dates but a common end date at 11 medical institutions in South Korea. Recruitment began on the following dates: Pusan National University Hospital (18 January 2023); Hallym University Kangnam Sacred Heart Hospital (11 January 2023); Kangbuk Samsung Hospital (8 March 2023); Kyungpook National University Hospital (19 January 2023); The Catholic University of Korea, Bucheon St. Mary’s Hospital (28 February 2023); Asan Medical Center (21 February 2023); Pusan National University Yangsan Hospital (20 March 2023); Yonsei University Wonju Severance Christian Hospital (13 January 2023); Inje University Busan Paik Hospital (4 January 2023); Korea University Guro Hospital (26 January 2023); Korea University Anam Hospital (9 February 2023). All recruitment ended on 15 May 2023. As it was Phase 2 trial, the sample size was not based on statistical power calculation. A target of 30 participants per group was set, and accounting for an anticipated 20% dropout rate, 38 participants per group (114 in total) were planned for enrollment. The study consisted of a 3-week screening period (visit 1 and washout period), 12-week double-blind treatment period (Visits 2–6), and a 2-week safety follow-up period. This study was approved by the Internal Institutional Review Board (IRB) and adhered to relevant ethical guidelines. All research procedures and treatments were performed in accordance with the 1964 Declaration of Helsinki and its later amendments, or equivalent ethical standards. All participants provided written informed consent (IRB number: 2209-003-129). This clinical trial was registered at ClinicalTrials.gov (Identifier: NCT05733624; https://clinicaltrials.gov/study/NCT05733624) and was first posted on February 17, 2023. The protocol was finalized before enrollment, and no changes were made to the protocol after participant enrollment began. The timing of the ClinicalTrials.gov posting did not reflect any modification of the study design.

Study population

This study consecutively included adult men and women aged 19 years who were diagnosed to have DED and met the eligibility criteria. To be eligible, at least one of both eyes had to meet all of the following criteria at the screening: 1) Corneal staining score (Oxford grading) of ≥2 and corneal conjunctival inflammation, 2) non-anesthesia tear secretion test (Schirmer’s test) result of ≤10 mm/5 min (or nasal stimulation tear volume test result of ≥3 mm/5 min if the non-anesthesia tear volume test is 0 mm/5 min), and 3) tear film break-up time (TBUT) test result of ≤10 s, with the maximum corrected visual acuity of both eyes being 0.7 LogMAR. The visual acuity criterion was applied to exclude participants with visually significant ocular comorbidities that could confound the assessment of dry eye–related outcomes, and visual acuity was monitored throughout the study as a safety measure to detect any blurred vision associated with study medication use. Participants were required to understand the clinical trial and provide written voluntary consent. Participants registering for this clinical trial were excluded if they meet any of the criteria listed in S1 Appendix.

Study protocol

Following the screening examination (Visit 1), registered participants underwent a discontinuation period (washout period) for at least 2 weeks from the previously administered treatment to eliminate the residual effects of prior dry eye treatments. If there is no ongoing dry eye treatment at clinical trial participation, the washout period may be omitted. At the baseline visit (Visit 2), the criteria were reevaluated, and eligible participants were randomly assigned to the following: study group 1 (SCAI-001 0.01%), study group 2 (SCAI-001 0.02%), or the control group (Restasis) in a 1:1:1 ratio. The randomization table was designed by an independent statistician using web-based statistical software (SAS, Version 9.4; SAS Institute, Cary, NC, USA) using the block randomization method with variable block size of 6 and 9. Investigators enrolling participants and those assigning interventions had no access to the sequence. Using an interactive web response system, the investigators assigned randomization numbers following the order of when the participants provided written consent. Participants, investigators, and outcome assessors were blinded to the group assignments until the database was locked. All study medications were identical in packaging to maintain blinding. Randomization codes were generated and kept by an independent statistician and were not disclosed to investigators or participants until study completion. Participants received the clinical trial medicine, one drop per eye, twice a day at 12-h intervals for 12 weeks and visited the hospital for examinations at weeks 1, 4, 8, and 12 (Visits 3–6) from the baseline visit. The visit, 12 weeks after baseline (Visit 6) marked the end of treatment for the investigational drug.

Efficacy assessments

The primary efficacy endpoint was the change in tear volume (Schirmer’s test) at 12 weeks compared with that of the baseline. Secondary efficacies included changes in tear volume at 4 and 8 weeks and changes in corneal staining score, conjunctival staining score, TBUT, standard patient evaluation of eye dryness questionnaire (SPEED) score, and ocular surface disease index (OSDI) scores at 4, 8, and 12 weeks compared to that of the baseline. Additionally, the study and control groups (SCAI-001 0.01% vs Restasis, SCAI-001 0.02% vs Restasis) were compared for evaluation variables at each time point.

Schirmer’s test.

To assess tear volume, a Schirmer’s test strip was placed inside the inferior temporal conjunctival sac for 5 minutes without topical anesthesia. The length of the tear-soaked area was measured in millimeters.

Corneal fluorescein staining.

Corneal staining was performed after fluorescein staining under slit-lamp illumination with a cobalt blue light source using a yellow filter. The degree of corneal staining was assessed on a 6-point scale according to the Oxford grading system.

Conjunctival Lissamine green staining.

After lissamine green staining, a drop of preservative-free normal saline was added to the stained area. The patient then blinked 3–4 times to evenly spread the dye over the tear film. The degree of conjunctival staining was then evaluated on a 6-point scale according to the Oxford grading system under a slit-lamp microscope.

TBUT.

TBUT was measured by observing the eyes after fluorescein staining under slit-lamp illumination using a cobalt blue light source. Spots, lines, or absences of fluorescein in the tear layer were noted from the time of the last blink, and the time until these observations was measured in seconds. The measurement was repeated three times in succession on the same eye, with the results recorded down to 1/100 seconds.

SPEED.

SPEED is designed to assess symptom severity, consisting of three items of symptom duration, frequency, and severity, with total scores ranging from 0 to 28 points. It evaluates the frequency (never occurs, 0 point; sometimes, 1 point; often, 2 points; and constant, 3 points) and severity (no special problems, 0 point; tolerable, 1 point; uncomfortable, 2 points; bothersome, 3 points; and intolerable, 4 points) of the dry eye symptoms experienced by the patient.

OSDI.

OSDI evaluates ocular symptoms (five questions), vision-related functions (four questions), and environmental factors that may cause symptoms (three questions). Each 12 questions are rated on a 5-point scale: none of the time, 0 point; some of the time, 1 point; half of the time, 2 points; most of the time, 3 points; and all of the time, 4 points.

Safety assessments

Ocular tolerability was assessed at 1, 4, 8, and 12 weeks of administration and extended for up to 14 weeks during the safety follow-up period. The severity of seven symptoms, including stinging/burning, itching, blurred vision, foreign body sensation, dryness, glare, and pain, was evaluated on a 4-level scale and scored (none, 0 point; mild, 1 point; moderate, 2 points; and severe, 3 points). Best-corrected visual acuity (BCVA), fundus examination, slit-lamp examination, conjunctival hyperemia, and intraocular pressure (IOP) were assessed at 1, 4, 8, 12 and 14 weeks. Abnormal findings at screening were collected as medical history, and after visit 1, clinically significant abnormal findings compared with that of the last visit were documented as adverse reactions.

Statistical analysis

Statistical analyses were performed using SAS (version 9.4 or higher, SAS Institute, Cary, NC, USA). Efficacy analyses were performed primarily on the full analysis set, which followed the intention-to-treat principle and included all participants who received at least one dose of the study drug and had at least one post-dose measurement of tear production using Schirmer’s test. Safety analyses were conducted on the safety set, defined as all participants who received at least one dose of the study drug and underwent at least one post-dose safety assessment. Missing data in efficacy endpoints for the full analysis set were handled by the last observation carried forward method. For the per-protocol set, analyses of efficacy and safety endpoints were performed using only available data without imputation. Normality of continuous data was assessed using the Shapiro–Wilk test. Continuous variables provided information on the number of observations; mean, standard deviation, median, minimum, and maximum values. Categorical variables are presented with frequency and percentage. We compared each study group to the control groups (SCAI-001 0.01% vs Restasis, SCAI-001 0.02% vs Restasis). Baseline characteristics and safety variables were analyzed using either a two-sample t-test or the Wilcoxon rank-sum test for continuous variables, depending on the normality assumption, and Pearson’s chi-square test or Fisher’s exact test for categorical variables, as appropriate. Within-group comparisons of each post-baseline value versus baseline for the efficacy endpoints were performed using the paired t-test or Wilcoxon’s signed-rank test, depending on the normality assumption. Between-group comparisons for the efficacy endpoints at each time point (weeks 4, 8, and 12) were performed using analysis of covariance (ANCOVA), adjusting for baseline values and clinical trial site. Given the exploratory nature of this Phase 2 study, no adjustment for multiplicity to control the type I error rate was applied for these comparisons. Accordingly, all secondary endpoint findings should be interpreted as exploratory. As a post-hoc sensitivity analysis, change in tear volume was additionally analyzed using a mixed model for repeated measures (MMRM).

Results

Patient demography

During the 2-week screening period, 128 patients were assessed, and 116 patients were randomly assigned to three groups. One participant was excluded for not taking medication, leaving 115 participants (40 in the SCAI-001 0.01% group, 37 in the SCAI-001 0.02% group, and 38 in the control group) for the full analysis set. Of total 116 randomized participants, 108 completed the study. Among these, 96 were included in the per-protocol set after excluding participants with predefined protocol deviations or investigational product compliance of < 80% (Fig 1). Reasons for withdrawal, baseline comparisons between completers and non-completers, and a sensitivity analysis using available cases are provided in S2 Appendix. No significant baseline differences were observed between completers and non-completers, and the sensitivity analysis showed no meaningful differences from the primary analysis. Among the 116 participants, 105 were female (90.5%), with no significant differences in sex, age, height, or weight between the study and control groups (Table 1).

Fig 1. Flow diagram of study.

Fig 1

FAS = full analysis set; PPS = per-protocol set. Reasons for exclusion from the PPS are not mutually exclusive, as some participants met more than one exclusion criterion.

Table 1. Baseline demographic characteristics.

SCAI-001 0.01% (N = 40) SCAI-001 0.02% (N = 38) Restasis (control)

(N = 38)
P-value
Sex (M:F, n[%]) 2:38 (5:95) 3:35 (7.9:92.1) 6:32 (15.8:84.2) 0.2715
Age (years) 45.93 ± 15.10(25–71) 44.79 ± 11.63 (24–67) 42.89 ± 12.38 (23–70) 0.6518
Age ≥ 50 (years, n[%]) 16 (40) 11 (28.9) 13 (34.1) 0.5899
Height (cm) 160.84 ± 4.38 (152.7–173) 160.50 ± 6.95 (147.1–179) 162.94 ± 7.78(149.6–183.5) 0.4493
Weight (kg) 56.92 ± 7.73(45.2–78.5) 57.23 ± 8.68 (44.7–80) 60.56 ± 10.75 (47–87.5) 0.2785

Efficacy outcomes

In both the FAS and PP, the change in tear volume at 12 weeks from baseline was significant in all groups. However, no significant differences were observed between the study and control groups. When analyzing the change in tear volume at 4 and 8 weeks, the SCAI-001 0.01% and SCAI-001 0.02% groups at 4 weeks as well as SCAI-001 0.02% and control groups at 8 weeks showed a significant increase compared with that of the baseline (Fig 2, Table 2). Sensitivity analysis using MMRM yielded results consistent with the ANCOVA findings for tear volume (S3 Appendix).

Fig 2. Mean change from baseline in tear volume by Schirmer’s test in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 2

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test).

Table 2. Baseline values and change from baseline of tear volume by Schirmer’s test in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

SCAI-001 0.01% (N = 40) P-value SCAI-001 0.02% (N = 37) P-value Control (Restasis) (N = 38) P-value
Schirmer’s test
Baseline 5.48 ± 2.43 5.89 ± 2.20 5.13 ± 2.35
4 weeks 7.68 ± 6.16 8.11 ± 4.72 5.82 ± 3.62
Change from baseline 2.20 ± 5.93 0.0081* 2.22 ± 3.77 0.0010* 0.68 ± 3.20 0.2997
8 weeks 7.30 ± 6.76 8.35 ± 4.69 7.50 ± 4.39
Change from baseline 1.83 ± 6.54 0.1572 2.46 ± 4.00 0.0005* 2.37 ± 4.08 0.0002*
12 weeks 8.43 ± 5.86 9.81 ± 7.21 7.26 ± 4.37
Change from baseline 2.95 ± 5.46 0.0013* 3.92 ± 6.85 0.0008* 2.13 ± 4.52 0.0075*

* Wilcoxon’s signed-rank test; Data are presented as mean ± standard deviation. P-values indicate the within-group comparison of each post-baseline value versus baseline. Baseline values and change from baseline for the secondary efficacy endpoints are presented in S4 Appendix.

Corneal staining showed significant improvements at 4, 8, and 12 weeks compared to that of the baseline in all three groups. However, no significant differences were observed between the study and control groups (Fig 3).

Fig 3. Mean change from baseline in corneal staining by Oxford grading in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 3

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test).

After 4 weeks of treatment, the conjunctival surface staining score showed significant improvement in both SCAI-001 0.01% and SCAI-001 0.02%, whereas Restasis did not demonstrate such improvement. At 8 and 12 weeks, all three groups showed significant improvements. When comparing the study and control groups, the change in the conjunctival staining score at 4 and 8 weeks in the SCAI-001 0.01% group was statistically significant compared to that of the control group (Fig 4).

Fig 4. Mean change from baseline in conjunctival staining by Oxford grading in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 4

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test). ‡ = statistically significant difference between groups (P < 0.05, ANCOVA).

Other secondary efficacy measures, including TBUT, SPEED, and OSDI, showed significant increases at 4, 8, and 12 weeks in all three groups compared to the baseline. However, there was no intergroup difference between the groups in each follow up period (Fig 5, Fig 6, Fig 7).

Fig 5. Mean change from baseline in tear film break-up time in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 5

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test). † = statistically significant difference from baseline (P < 0.05, paired t-test).

Fig 6. Mean change from baseline in SPEED score in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 6

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test). † = statistically significant difference from baseline (P < 0.05, paired t-test).

Fig 7. Mean change from baseline in OSDI score in SCAI-001 0.01%, SCAI-001 0.02%, and Restasis group at 4, 8, and 12 weeks.

Fig 7

* = statistically significant difference from baseline (P < 0.05, Wilcoxon signed-rank test). † = statistically significant difference from baseline (P < 0.05, paired t-test).

Safety outcomes

In the ocular tolerability evaluation, no differences were observed in the severity scores of the seven symptoms between the study and control groups (Fig 8). Additionally, no significant between-group differences were observed in BCVA, fundus examination, slit-lamp examination, or IOP at any study visit.

Fig 8. Change in ocular tolerability symptom from baseline with intergroup comparison.

Fig 8

No significant difference was observed in the symptom scores at each visit between the SCAI-001 and Restasis groups. (all P > 0.05; Wilcoxon rank-sum test).

Discussions

This study utilized Molecular Associated Innovative Substance technology to enhance the solubility of cyclosporine using a minimal amount of surfactant. This approach yielded SCAI-001 eye drops with improved solubility and ocular penetration. In the present study, both SCAI-001 concentrations produced significant within-group improvements from baseline in tear volume by Schirmer’s test, corneal and conjunctival staining scores, TBUT, SPEED, and OSDI scores throughout the 12-week treatment period, with an ocular tolerability profile comparable to that of Restasis. Although SCAI-001 did not show statistically significant between-group superiority over Restasis on these measures, these findings suggest that a substantially reduced cyclosporine concentration can still achieve efficacy and safety comparable to the standard 0.05% formulation, enabled by enhanced drug solubility and ocular penetration.

Primary efficacy exhibited significant improvements in all three groups, indicating that, by reducing inflammation with cyclosporine, the integrity of the corneal epithelium increases, leading to enhanced stimulation of sensory nerve endings in the cornea and conjunctiva, ultimately normalizing nerve transmission signals to the lacrimal gland [11,25]. Consequently, both quantitative and qualitative improvements in lacrimal gland-produced tears were observed, suggested by a more favorable Schirmer’s test outcome.

Regarding the secondary efficacies of tear volume changes at 4 and 8 weeks, both the SCAI-001 0.01% and SCAI-001 0.02% groups showed significant increases at 4 weeks, whereas the SCAI-001 0.02% and Restasis groups displayed significant changes at 8 weeks. Compared to Restasis, the increase in tear secretion observed at the initial 4-week period following the use of SCAI eye drops may stems from the formation of more stable nanosized uniform molecules, which are expected to enhance its corneal solubility [9,13,16,26]. In contrast, Restasis may face challenges due to its non-uniform particle size, ranging from 67 to 2,489 nm, leading to potential instability and lower corneal permeability [14,27,28]. However, the comparison between the study and control groups did not yield significant differences in tear volume changes at each time point (Fig 2). Further clinical studies are needed to clarify how particle size uniformity contributes to this exploratory earlier clinical outcome in tear volume.

SCAI-001 0.01%, and SCAI-001 0.02% eye drops exhibited significant changes in dry eye indicators, including corneal staining, conjunctival staining, and TBUT at 4, 8, and 12 weeks. Corneal staining, conjunctival staining, and TBUT depend on mucus deficiency, meibomian gland dysfunction, and corneal epithelium stability [29]. Han et al. reported that the higher the cyclosporine concentration, the greater the effect [12]. However, in this study, even at low concentrations of SCAI-001 (0.01% and 0.02%), improvement in dry eye indicators was observed to be similar to Restasis. In particular, the improvement in the conjunctival staining scores at 4 and 8 weeks in the SCAI-001 0.01% group was significantly greater than that in the Restasis group (Fig 4). This may be partly explained by the lower surfactant content of SCAI-001 relative to Restasis, given that ophthalmic surfactants such as polysorbate 80 have been shown to exert dose-dependent cytotoxic and irritant effects on the conjunctival eye assays [30]. Similarly, CyclASol, a water-free cyclosporine 0.1% formulation that eliminates the need for solubilizing surfactants altogether, demonstrated significantly greater improvement in conjunctival staining compared with Restasis [31].

The overall results are consistent with a growing body of evidence on nanotechnology-based cyclosporine formulations. Rao et al. demonstrated that a micellar nanoparticulate cyclosporine 0.05% emulsion achieved efficacy exceeding conventional Restasis on Schirmer’s test, ocular surface staining, and OSDI scores in a multicenter, active-controlled trial [32]. Similarly, Eom et al. reported that a 0.08% nanoemulsion cyclosporine formulation administered once daily achieved noninferior improvements in OSDI, TBUT, ocular surface staining, and Schirmer’s test compared with conventional 0.05% cyclosporine administered twice daily [33]. A recent meta-analysis of seven randomized trials likewise found that nanoemulsion-based cyclosporine formulations produced significant improvements in TBUT and Schirmer’s test relative to conventional formulations [34]. Taken together with the present results, these data support the premise that nanosizing strategies can preserve therapeutic efficacy while allowing a reduction in concentration or dosing frequency.

In chronic diseases that require continuous use of eye drops over a long period, patient compliance with medication is very important for successful treatment. Non-compliance in patients with DED can lead to blurred vision and social concerns such as reduced work productivity and reduced quality of life [10]. According to various reports, patients using topical anti-inflammatory eye drops such as 0.05% cyclosporine or lifitegrast have been reported to experience discomfort, itching, or burning sensation during instillation, leading to non-compliance or medication discontinuation in 2.5–60% of cases [25,35].

In this study, discomfort was expected to improve with SCAI-001 eye drops, as it reduces the surfactant concentration. However, no significant difference was observed in the intraocular tolerance between the SCAI-001 and Restasis groups (Fig 8). This was a Phase 2 clinical trial, which is primarily designed to generate preliminary evidence on dose-response relationships and efficacy signals to inform subsequent Phase 3 development, rather than to provide confirmatory comparisons of safety and tolerability outcomes. Accordingly, the sample size was determined based on the primary efficacy endpoint (change in Schirmer’s test score at 12 weeks), and the study was not specifically powered to detect between-group differences in ocular tolerability. Therefore, the absence of statistically significant differences in symptom severity scores may not be interpreted as definitive evidence of equivalent irritation profiles. Adequately powered Phase 3 trials with tolerability-specific endpoints will be necessary to confirm whether the reduced excipient content of SCAI-001 confers a meaningful advantage in ocular comfort.

Even though the mechanism whereby irritation occurs when instilling cyclosporine is poorly understood, it is known that the surfactant used to create a mixed form of cyclosporine emulsion stimulates the transient receptor potential vanilloid type 1 (TRPV1), also known as the capsaicin receptor. This stimulation induces ocular surface irritation [24]. According to studies on cyclosporine in young female patients, factors with higher ocular surface staining scores, higher expression levels of matrix metalloproteinase 9 in tears, lower tear secretion, and shorter therapeutic durations of eye drops exhibit poor compliance and complaints of discomfort [10,18]. Chronic inflammation on the ocular surface sensitizes the corneal peripheral sensory nerves inducing neuroplastic changes, making TRPV1 more easily, spontaneously, or exaggerated [36,37]. This suggests that compliance may be reduced in patients with relatively severe inflammation associated with DED. In future studies, it will be necessary to evaluate ocular tolerability and compliance with low-dose cyclosporine based on the degree of dry eye and inflammation.

A limitation of this study is that tear volume by Schirmer’s test, the primary efficacy endpoint, is known to have high measurement variability due to reflex tearing during the test procedure. While this endpoint was chosen based on regulatory precedent and consistency with the reference drug’s pivotal trials, as well as its relevance to the mechanism of action of cyclosporine, future studies may benefit from adopting co-primary sign-and-symptom endpoints, such as corneal staining combined with a validated symptom score, as increasingly recommended by regulatory guidance for dry eye disease trials [38,39].

This Phase 2 study investigated the clinical efficacy and safety of low concentrations of cyclosporine for treating dry eye symptoms. Both the SCAI-001 0.01% and SCAI-001 0.02% formulations showed improvements in objective measures such as tear secretion, corneal and conjunctival surface staining scores, and TBUT over 12 weeks, as well as subjective measures such as SPEED and OSDI, comparable to that of Restasis. They also showed earlier increases in tear volume and better conjunctival improvement compared to Restasis but these exploratory findings were not confirmed by significant between-group differences and warrant further investigation in a larger Phase 3 trial. In conclusion, low-concentration cyclosporine eye drops should be further developed as an effective treatment for DED.

Supporting information

S1 Appendix. Exclusion criteria for the randomized controlled trial.

(DOCX)

pone.0358007.s001.docx (14.4KB, docx)
S2 Appendix. Reason for withdrawal by treatment group, comparison of baseline characteristics between study completers and non-completers, and sensitivity analysis of the primary efficacy endpoint using a mixed-effects model for repeated measures.

(DOCX)

pone.0358007.s002.docx (20.2KB, docx)
S3 Appendix. Sensitivity analysis of change in tear volume by Schirmer’s test from baseline using a mixed model for repeated measures.

(DOCX)

pone.0358007.s003.docx (21.3KB, docx)
S4 Appendix. Baseline values and change from baseline for secondary efficacy endpoints by visit and treatment group.

(DOCX)

pone.0358007.s004.docx (18.4KB, docx)
S1 Checklist. CONSORT checklist.

(DOCX)

pone.0358007.s005.docx (34.7KB, docx)
S1 Fig. CONSORT flow diagram of study participants.

(DOCX)

pone.0358007.s006.docx (64.1KB, docx)
S1 Protocol. Study protocol.

(PDF)

pone.0358007.s007.pdf (1.6MB, pdf)
S1 Dataset. Study dataset.

(ZIP)

Data Availability

All relevant data are within the paper and its Supporting information files.

Funding Statement

This research was supported by SCAI Therapeutics (Protocol No. SCAI‑001‑201; funder website: https://scaitrx.com/). SCAI Therapeutics funded the study and provided the investigational product. Research funding was provided to the participating institutions to support study conduct in accordance with the clinical trial agreement. The sponsor participated in study design, data collection oversight, data management, and statistical analysis. However, SCAI Therapeutics did not participate in manuscript drafting or preparation. The authors retained responsibility for data interpretation and the decision to submit the manuscript for publication.

References

  • 1.Wolffsohn JS, Benítez-Del-Castillo JM, Loya-Garcia D, et al. TFOS DEWS III: diagnostic methodology. Am J Ophthalmol. 2025;279:387–450. [DOI] [PubMed] [Google Scholar]
  • 2.Jung HH, Kang YS, Sung MS, Yoon KC. Clinical efficacy of topical 3% diquafosol tetrasodium in short tear film break-up time dry eye. J Korean Ophthalmol Soc. 2015;56(3):339. doi: 10.3341/jkos.2015.56.3.339 [DOI] [Google Scholar]
  • 3.Farrand KF, Fridman M, Stillman IÖ, Schaumberg DA. Prevalence of diagnosed dry eye disease in the United States among adults aged 18 years and older. Am J Ophthalmol. 2017;182:90–8. [DOI] [PubMed] [Google Scholar]
  • 4.Craig JP, Nichols KK, Akpek EK, Caffery B, Dua HS, Joo CK, et al. TFOS DEWS II definition and classification report. Ocul Surf. 2017;15:276–83. [DOI] [PubMed] [Google Scholar]
  • 5.Nelson JD, Craig JP, Akpek EK, Azar DT, Belmonte C, Bron AJ, et al. TFOS DEWS II Introduction. Ocul Surf. 2017;15:269–75. [DOI] [PubMed] [Google Scholar]
  • 6.Matsuda S, Koyasu S. Mechanisms of action of cyclosporine. Immunopharmacology. 2000;47(2–3):119–25. [DOI] [PubMed] [Google Scholar]
  • 7.Kunert KS, Tisdale AS, Stern ME, Smith JA, Gipson IK. Analysis of topical cyclosporine treatment of patients with dry eye syndrome: effect on conjunctival lymphocytes. Arch Ophthalmol. 2000;118(11):1489–96. doi: 10.1001/archopht.118.11.1489 [DOI] [PubMed] [Google Scholar]
  • 8.Bian X, Ma J, Liu Y, Feng Y, Liu Z, Zhang B, et al. Cyclosporine a in the treatment of dry eye disease: a narrative review. Front Ophthalmol (Lausanne). 2025;5:1700163. doi: 10.3389/fopht.2025.1700163 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Periman LM, Mah FS, Karpecki PM. A review of the mechanism of action of cyclosporine a: the role of cyclosporine A in dry eye disease and recent formulation developments. Clin Ophthalmol. 2020;14:4187–200. doi: 10.2147/OPTH.S279051 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Lee WJ, Chun YS, Kim KW. Contributing factors affecting ocular discomfort on instillation and compliance of 0.1% cyclosporine A cationic nanoemulsion. J Korean Ophthalmol Soc. 2021;62(4):429–38. doi: 10.3341/jkos.2021.62.4.429 [DOI] [Google Scholar]
  • 11.Yang S, Byun Y-S, Rho CR, Kim SY, Cho YK, Kim EC, et al. Comparisons for evaluation of efficacy and safety of cyclosporin A 0.05% ophthalmic emulsion treatment groups. J Korean Ophthalmol Soc. 2016;57(12):1849. doi: 10.3341/jkos.2016.57.12.1849 [DOI] [Google Scholar]
  • 12.Han H, Choi S. Comparison of the effects of 0.05% and 0.1% cyclosporine for dry eye syndrome patients after cataract surgery. J Korean Ophthalmol Soc. 2023;64(11):987–1000. doi: 10.3341/jkos.2023.64.11.987 [DOI] [Google Scholar]
  • 13.Shin EH, Lim DH, Yang CM, Chung T-Y. Comparison of efficacy and sensation of instillation between 0.05% cyclosporine nanoemulsion and microemulsion type. J Korean Ophthalmol Soc. 2019;60(3):239. doi: 10.3341/jkos.2019.60.3.239 [DOI] [Google Scholar]
  • 14.Lee JS, Yoon TJ, Kim KH. Cinical effect of Restasis® eye drops in mild dry eye syndrome. J Korean Ophthalmol Soc. 2009;50(10):1489. doi: 10.3341/jkos.2009.50.10.1489 [DOI] [Google Scholar]
  • 15.Kang H, Seong S, Choe CM, Kim SK, Choi TH. The effect of topical cyclosporine 0.05% on tear osmolarity for dry eye syndrome. J Korean Ophthalmol Soc. 2015;56(2):174. doi: 10.3341/jkos.2015.56.2.174 [DOI] [Google Scholar]
  • 16.Ji M, Choi CY, Kim S-J, Jeong J. The efficacies and safeties of a 0.05% cyclosporine nanoemulsion and a 0.1% cyclosporine cationic emulsion. J Korean Ophthalmol Soc. 2022;63(10):834–40. doi: 10.3341/jkos.2022.63.10.834 [DOI] [Google Scholar]
  • 17.Chen K-Y, Chan H-C, Chan C-M. Which topical ophthalmic drugs work best for Keratoconjunctivitis Sicca? A systematic review and meta-analysis. Naunyn Schmiedebergs Arch Pharmacol. 2026;399(1):769–82. doi: 10.1007/s00210-025-04454-8 [DOI] [PubMed] [Google Scholar]
  • 18.So HR, Baek J, Lee JY, Kim HS, Kim MS, Kim EC. Comparison of matrix metallopeptidase-9 expression following cyclosporine and diquafosol treatment in dry eye. Ann Med. 2023;55(1):2228192. doi: 10.1080/07853890.2023.2228192 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Lee JH, Song IS, Kim KL, Yoon SY. Effectiveness and optical quality of topical 3.0% diquafosol versus 0.05% cyclosporine A in dry eye patients following cataract surgery. J Ophthalmol. 2016;2016:8150757. doi: 10.1155/2016/8150757 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Ames P, Galor A. Cyclosporine ophthalmic emulsions for the treatment of dry eye: a review of the clinical evidence. Clin Investig (Lond). 2015;5(3):267–85. doi: 10.4155/cli.14.135 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Ayaki M, Yaguchi S, Iwasawa A, Koide R. Cytotoxicity of ophthalmic solutions with and without preservatives to human corneal endothelial cells, epithelial cells and conjunctival epithelial cells. Clin Exp Ophthalmol. 2008;36(6):553–9. doi: 10.1111/j.1442-9071.2008.01803.x [DOI] [PubMed] [Google Scholar]
  • 22.Park DH, Jin HN, Yoon HS, Yoon HJ, Yoon K-C. Assessment of the compliance with 0.1% cyclosporine A in dry-eye patients with Sjögren’s syndrome. J Korean Ophthalmol Soc. 2021;62(7):895–903. doi: 10.3341/jkos.2021.62.7.895 [DOI] [Google Scholar]
  • 23.Labetoulle M, Leonardi A, Amrane M, Ismail D, Garrigue J-S, Garhöfer G, et al. Persistence of efficacy of 0.1% cyclosporin A cationic emulsion in subjects with severe keratitis due to dry eye disease: a nonrandomized, open-label extension of the SANSIKA study. Clin Ther. 2018;40(11):1894–906. doi: 10.1016/j.clinthera.2018.09.012 [DOI] [PubMed] [Google Scholar]
  • 24.Lilja J, Lindegren H, Forsby A. Surfactant-induced TRPV1 activity--a novel mechanism for eye irritation? Toxicol Sci. 2007;99(1):174–80. doi: 10.1093/toxsci/kfm164 [DOI] [PubMed] [Google Scholar]
  • 25.Sall K, Stevenson OD, Mundorf TK, Reis BL. Two multicenter, randomized studies of the efficacy and safety of cyclosporine ophthalmic emulsion in moderate to severe dry eye disease. CsA Phase 3 Study Group. Ophthalmology. 2000;107(4):631–9. doi: 10.1016/s0161-6420(99)00176-1 [DOI] [PubMed] [Google Scholar]
  • 26.Anton N, Vandamme TF. Nano-emulsions and micro-emulsions: clarifications of the critical differences. Pharm Res. 2011;28(5):978–85. doi: 10.1007/s11095-010-0309-1 [DOI] [PubMed] [Google Scholar]
  • 27.Kale D. Emulsion micro emulsion and nano emulsion: a review. 2016. [Google Scholar]
  • 28.Anton V. Nano-emulsions and micro-emulsions clarifications. 2011. [DOI] [PubMed] [Google Scholar]
  • 29.Methodologies to diagnose and monitor dry eye disease: report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007). Ocul Surf. 2007;5(2):108–52. doi: 10.1016/s1542-0124(12)70083-6 [DOI] [PubMed] [Google Scholar]
  • 30.Al-Qaysi ZK, Al-Kinani AA, Alany RG. Ocular irritation potential and cytotoxicity of selected surfactants and cosurfactants: identifying suitable concentrations for topical ophthalmic formulations. Sci Pharm. 2026;94(2):46. [Google Scholar]
  • 31.Wirta DL, Torkildsen GL, Moreira HR, Lonsdale JD, Ciolino JB, Jentsch G, et al. A clinical phase II study to assess efficacy, safety, and tolerability of waterfree cyclosporine formulation for treatment of dry eye disease. Ophthalmology. 2019;126(6):792–800. doi: 10.1016/j.ophtha.2019.01.024 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Rao AT, Gupta A, Chauhan T, Basu S, Batra N, Sharma N, et al. Efficacy and safety of 0.05% micellar nano-particulate (MNP) cyclosporine ophthalmic emulsion in the treatment of moderate-to-severe keratoconjunctivitis sicca: a 12-week, multicenter, randomized, active-controlled trial. BMC Ophthalmol. 2023;23(1):121. doi: 10.1186/s12886-023-02838-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 33.Eom Y, Yoon KC, Kim HK, Song JS, Hyon JY, Kim HM. A multicenter, randomized, double-blind evaluation of the efficacy of TJO-087 versus 0.05% cyclosporine A in moderate to severe dry eye. J Ocul Pharmacol Ther. 2023;39(1):27–35. doi: 10.1089/jop.2022.0119 [DOI] [PubMed] [Google Scholar]
  • 34.Gouhiri AB, Aldemerdash MA, Zitouni N-O, Otmani Z, Abbas OF, Aldiban W, et al. The efficacy and safety of nanoemulsion compared to conventional cyclosporine in dry eye disease: a systematic review and meta-analysis. AJO Int. 2025;2(3):100143. doi: 10.1016/j.ajoint.2025.100143 [DOI] [Google Scholar]
  • 35.Byun YS, Lee JH, Park JH, Kim MK, Kim SJ, Joo CK. Cyclosporine 0.05% ophthalmic emulsion for dry eye in Korea: a prospective, multicenter, open-label, surveillance study. Korean J Ophthalmol. 2011;25:369–74. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Galor A, Moein H-R, Lee C, Rodriguez A, Felix ER, Sarantopoulos KD, et al. Neuropathic pain and dry eye. Ocul Surf. 2018;16(1):31–44. doi: 10.1016/j.jtos.2017.10.001 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Bereiter DA, Rahman M, Thompson R, Stephenson P, Saito H. TRPV1 and TRPM8 channels and nocifensive behavior in a rat model for dry eye. Invest Ophthalmol Vis Sci. 2018;59(8):3739–46. doi: 10.1167/iovs.18-24304 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 38.de Oliveira RC, Wilson SE. Practical guidance for the use of cyclosporine ophthalmic solutions in the management of dry eye disease. Clin Ophthalmol. 2019;13:1115–22. doi: 10.2147/OPTH.S184412 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Goldberg DF, Malhotra RP, Schechter BA, Justice A, Weiss SL, Sheppard JD. A phase 3, randomized, double-masked study of OTX-101 ophthalmic solution 0.09% in the treatment of dry eye disease. Ophthalmology. 2019;126(9):1230–7. doi: 10.1016/j.ophtha.2019.03.050 [DOI] [PubMed] [Google Scholar]

Decision Letter 0

Kofi Asiedu

7 Jun 2026

Dear Dr. Lee,

Thank you for submitting your manuscript to PLOS ONE. After careful consideration, we feel that it has merit but does not fully meet PLOS ONE’s publication criteria as it currently stands. Therefore, we invite you to submit a revised version of the manuscript that addresses the points raised during the review process.

==============================

For Lab, Study and Registered Report Protocols: These article types are not expected to include results but may include pilot data.

==============================

Please submit your revised manuscript by Jul 22 2026 11:59PM. If you will need more time than this to complete your revisions, please reply to this message or contact the journal office at plosone@plos.org. When you're ready to submit your revision, log on to https://www.editorialmanager.com/pone/ and select the 'Submissions Needing Revision' folder to locate your manuscript file.

  • A letter that responds to each point raised by the academic editor and reviewer(s). You should upload this letter as a separate file labeled 'Response to Reviewers'.

  • A marked-up copy of your manuscript that highlights changes made to the original version. You should upload this as a separate file labeled 'Revised Manuscript with Track Changes'.

  • An unmarked version of your revised paper without tracked changes. You should upload this as a separate file labeled 'Manuscript'.

If you would like to make changes to your financial disclosure, please include your updated statement in your cover letter. Guidelines for resubmitting your figure files are available below the reviewer comments at the end of this letter.

If applicable, we recommend that you deposit your laboratory protocols in protocols.io to enhance the reproducibility of your results. Protocols.io assigns your protocol its own identifier (DOI) so that it can be cited independently in the future. For instructions see: https://journals.plos.org/plosone/s/submission-guidelines#loc-laboratory-protocols. Additionally, PLOS ONE offers an option for publishing peer-reviewed Lab Protocol articles, which describe protocols hosted on protocols.io. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols.

As the corresponding author, your ORCID iD is verified in the submission system and will appear in the published article. PLOS supports the use of ORCID, and we encourage all coauthors to register for an ORCID iD and use it as well. Please encourage your coauthors to verify their ORCID iD within the submission system before final acceptance, as unverified ORCID iDs will not appear in the published article. Only  the individual author can complete the verification step; PLOS staff cannot  verify ORCID iDs on behalf of authors.

We look forward to receiving your revised manuscript.

Kind regards,

Kofi Asiedu, O.D., Ph.D. FAAO

Academic Editor

PLOS One

Journal Requirements:

When submitting your revision, we need you to address these additional requirements.

1. Please ensure that your manuscript meets PLOS ONE's style requirements, including those for file naming. The PLOS ONE style templates can be found at

https://journals.plos.org/plosone/s/file?id=wjVg/PLOSOne_formatting_sample_main_body.pdf and

https://journals.plos.org/plosone/s/file?id=ba62/PLOSOne_formatting_sample_title_authors_affiliations.pdf

2. Please upload a new copy of Figure 8 as the detail is not clear. Please follow the link for more information:  https://journals.plos.org/plosone/s/figures

3. Original Protocol Contains Confidentiality Notice.

4. Original Protocol Contains Logo.

5. Please include captions for your Supporting Information files at the end of your manuscript, and update any in-text citations to match accordingly. Please see our Supporting Information guidelines for more information: http://journals.plos.org/plosone/s/supporting-information.

6. Thank you for providing your underlying data as Supporting Information.

We note that the data set contains text or data that is not in English. Please note that PLOS is an English-language publisher, so we require data sets to be provided in English as well. Please upload an English-language version of your data set.

This will also allow us to determine if your data follows PLOS standards per our Data Availability policy here: https://journals.plos.org/plosone/s/data-availability

7. We note that there is identifying data in the Supporting Information file “Supporting information.zip”. Due to the inclusion of these potentially identifying data, we have removed this file from your file inventory. Prior to sharing human research participant data, authors should consult with an ethics committee to ensure data are shared in accordance with participant consent and all applicable local laws.

Data sharing should never compromise participant privacy. It is therefore not appropriate to publicly share personally identifiable data on human research participants. The following are examples of data that should not be shared:

-Name, initials, physical address

-Ages more specific than whole numbers

-Internet protocol (IP) address

-Specific dates (birth dates, death dates, examination dates, etc.)

-Contact information such as phone number or email address

-Location data

-ID numbers that seem specific (long numbers, include initials, titled “Hospital ID”) rather than random (small numbers in numerical order)

Data that are not directly identifying may also be inappropriate to share, as in combination they can become identifying. For example, data collected from a small group of participants, vulnerable populations, or private groups should not be shared if they involve indirect identifiers (such as sex, ethnicity, location, etc.) that may risk the identification of study participants.

Additional guidance on preparing raw data for publication can be found in our Data Policy (https://journals.plos.org/plosone/s/data-availability#loc-human-research-participant-data-and-other-sensitive-data) and in the following article: http://www.bmj.com/content/340/bmj.c181.long.

Please remove or anonymize all personal information “ID”, ensure that the data shared are in accordance with participant consent, and re-upload a fully anonymized data set. Please note that spreadsheet columns with personal information must be removed and not hidden as all hidden columns will appear in the published file.

8. If the reviewer comments include a recommendation to cite specific previously published works, please review and evaluate these publications to determine whether they are relevant and should be cited. There is no requirement to cite these works unless the editor has indicated otherwise.

9. Please review your reference list to ensure that it is complete and correct. If you have cited papers that have been retracted, please include the rationale for doing so in the manuscript text, or remove these references and replace them with relevant current references. Any changes to the reference list should be mentioned in the rebuttal letter that accompanies your revised manuscript. If you need to cite a retracted article, indicate the article’s retracted status in the References list and also include a citation and full reference for the retraction notice.

[Note: HTML markup is below. Please do not edit.]

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

1. Is the manuscript technically sound, and do the data support the conclusions?

Reviewer #1: Partly

Reviewer #2: Yes

Reviewer #3: Partly

Reviewer #4: Partly

**********

2. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: No

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: No

Reviewer #2: Yes

Reviewer #3: No

Reviewer #4: Yes

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: No

Reviewer #2: Yes

Reviewer #3: Yes

Reviewer #4: No

**********

Reviewer #1: A sample size calculation is critical for this study design.

For a longitudinal study, a linear mixed model or a generalized estimating equations (GEE) approach is recommended. Both within-group and between-group comparisons can be performed in a single model. GEE can accommodate non-normal outcomes, and baseline values can be adjusted as covariates. Linear mixed/GEE models also handle data that are missing at random reasonably well. T-tests use less data with reducing statistical power. Consult a statistician especially for the primary analysis.

Present a table showing baseline values and change from baseline at each time point, at least for the primary outcome. P-values may need adjustment for secondary outcomes.

What was the block size used for randomization?

Table 1 should assess balance across all three groups, not only treatment vs control. There is no need to label the statistical method in the p-value column; instead, specify the methods in the Statistical Analysis section (e.g., continuous variables were compared using t-tests and categorical variables using chi-square tests).

In Figure 1, “Safety” should replace “Saftey.” Replace “Safety Set” with “FAS,” and omit “Excluded from the FAS n=0.” There is no need to show safety set in the flow diagram.

In addition, the exclusion criteria for the PPS are unclear. For example, is use of a contraindicated drug considered a compliance issue or a protocol deviation/violation also?

Clarify the reasons for dropouts (e.g., lack of efficacy vs safety-related reasons).

Reviewer #2: The manuscript entitled “Comparative study on the clinical effectiveness of low-concentration cyclosporine eye drops in patients with dry eye syndrome” addresses a clinically relevant question regarding whether lower-concentration nanoparticle-based cyclosporine formulations can provide comparable efficacy and tolerability to conventional cyclosporine 0.05% emulsion in dry eye syndrome. The multicenter, randomized, double-blind design is a strength, and the topic is potentially valuable. However, the present manuscript requires several important corrections before it can be considered acceptable. I recommend minor revision, provided that the authors address the following points rigorously.

First, the trial-registration timing must be clarified transparently. The manuscript states that recruitment began on 4 January 2023 and that ClinicalTrials.gov registration was first posted on 17 February 2023. This raises concern that the trial may have been registered after participant recruitment had already started. The authors must explicitly state whether registration was prospective or retrospective, whether the protocol was finalized before enrollment, and whether any outcomes were changed after enrollment began.

Second, the interpretation of efficacy is too favorable relative to the actual primary endpoint. The primary endpoint was change in tear volume at 12 weeks, and although all groups improved from baseline, there were no significant intergroup differences. Therefore, the conclusion should not imply superiority of SCAI-001. The authors should state clearly that SCAI-001 showed comparable efficacy to Restasis, while the earlier 4-week tear-volume improvement was exploratory and not supported by significant between-group difference.

Third, the statistical analysis requires clearer correction for multiplicity. The manuscript reports many secondary outcomes across multiple time points, including Schirmer’s test, corneal staining, conjunctival staining, TBUT, SPEED, and OSDI at 4, 8, and 12 weeks. Without adjustment for multiple comparisons, isolated findings such as better conjunctival staining with SCAI-001 0.01% at weeks 4 and 8 may be false-positive. The authors should clarify whether multiplicity adjustment was planned or explicitly label these findings exploratory.

Fourth, the handling of missing data and attrition requires more detailed justification. Of 116 randomized participants, only 96 completed the study and were included in the per-protocol set. The authors used last observation carried forward for missing efficacy endpoints. This approach can bias treatment-effect estimation in dry eye trials with fluctuating symptoms. The authors should provide reasons for withdrawal by group, compare baseline features of completers and non-completers, and add sensitivity analyses using available-case or mixed-model methods.

Fifth, the conflict-of-interest and funding statements require careful revision. The submission form states that SCAI Therapeutics supported the study and had a role in study design, data collection, and analysis, yet the competing-interest statement says that no competing interests exist. This is not sufficiently transparent. The authors should explicitly disclose sponsor involvement in trial design, product supply, data management, statistical analysis, manuscript preparation, and publication decisions, and clarify whether any authors received payment, consulting support, or institutional funding.

Sixth, the manuscript would benefit from more comprehensive contextualization within the current dry eye disease treatment landscape. Several relevant systematic reviews and meta-analyses addressing topical therapy, ocular surface management, and adjunctive dry eye interventions should be considered to strengthen the Introduction and Discussion. The following listed 4 studies are very helpful to consider for citation: 1. PMID: 40679590; DOI: 10.1007/s00210-025-04454-8, because it directly compares topical ophthalmic drugs for keratoconjunctivitis sicca and is highly relevant to positioning cyclosporine among current pharmacologic options; 2. PMID: 40393913; DOI: 10.1016/j.clae.2025.102438, because punctal plugs are a commonly used non-pharmacologic strategy and provide broader context for tear-volume improvement in dry eye disease; 3. PMID: 40352434; DOI: 10.1177/25158414251338775, because thermal pulsation therapy is relevant to meibomian gland dysfunction-associated dry eye and helps contextualize non-immunomodulatory treatment approaches; and 4. PMID: 40204900; DOI: 10.1038/s41433-025-03790-6, because botulinum toxin A represents an emerging dry eye intervention and broadens the discussion of current and developing therapeutic strategies.

Overall, this manuscript addresses an important therapeutic question and provides useful randomized clinical data. However, the authors must correct the trial-registration transparency issue, moderate efficacy claims, address multiplicity, clarify attrition and missing-data handling, and improve disclosure of sponsor involvement. After these minor but necessary revisions, the manuscript can be accepted for publication.

Reviewer #3: 1. Missing data on baseline dry eye severity. Please supplement this part of the results. Baseline imbalance could confound results.

2. In this Clinical Trial, the primary efficacy endpoint was the change in tear volume after 12 weeks. While, as we all known, the Schirmer test, with poor reproducibility and high stimulation effect, has a high coefficient of variation, is of limited clinical relevance compared to objective signs like corneal staining and BUT. Please explain the reason for using tear volume as the primary efficacy endpoint.

3. As authors has mentioned in the introduction, SCAI eye drops (0.01% and 0.02% cyclosporine) with lower concentrations, aiming to alleviate discomfort such as ocular irritation and foreign body sensation caused by the formulation of conventional cyclosporine eye drop such as 0.05% cyclosporine (Restasis, Allergan Inc.). While, safety outcomes showed that in theocular tolerability evaluation, no differences were determined in the severity scores of the sev-en symptoms between the study and control groups. Does this result deviate from the mai-n purpose of the innovative low‑concentration cyclosporine eye drops?

Reviewer #4: This study is good one in the field of dry eye management. There are some issues in introduction, methodology and discussion. This study has problems in language, sentence construction and some repetition. Best wishes!

Line 63: please mention mechanism of action in detail.

Line 119: What sampling technique was used?

Line 119: This study included adult men and women aged 19 years who were diagnosed to have DES. (need to change the present line with this one)

Line 122: Why is visual acuity significant in case of dry eye syndrome?

Line 131: Why was washout period of 2 week considered?

Line 135: How have you differentiated treatment group and control group as restasis is not a placebo treatment?

Line 160: How have you addressed reflex lacrimation?

Line 199: Restructure the sentence.

Line 209: Does this mean the patients with only one post-drug follow up were also included in the analysis?

Line 285: Restructure the sentence.

Line 291: Discussion portion lack comparison of the results with similar study.

Line 292: This first paragraph of discussion seems similar to the introduction. So kindly omt repetition.

Please add conclusion.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #2: No

Reviewer #3: No

Reviewer #4: Yes: Raju Kaiti

**********

[NOTE: If reviewer comments were submitted as an attachment file, they will be attached to this email and accessible via the submission site. Please log into your account, locate the manuscript record, and check for the action link "View Attachments". If this link does not appear, there are no attachment files.]

To ensure your figures meet our technical requirements, please review our figure guidelines: https://journals.plos.org/plosone/s/figures

You may also use PLOS’s free figure tool, NAAS, to help you prepare publication quality figures: https://journals.plos.org/plosone/s/figures#loc-tools-for-figure-preparation.

NAAS will assess whether your figures meet our technical requirements by comparing each figure against our figure specifications.

PLoS One. 2026 Sep 28;21(9):e0358007. doi: 10.1371/journal.pone.0358007.r002

Author response to Decision Letter 1


5 Aug 2026

Reviewer #1:

1. A sample size calculation is critical for this study design.

: As it is a Phase 2 study as specified in the study protocol (Section 11.3), the sample size was determined not based on statistical power calculation but based on the exploratory nature of the study. Considering 30 subjects per group plus a 20% drop-out rate for exploratory investigation, the study plans to recruit 38 subjects per treatment group. We have revised the Methods section of the manuscript to state this rationale (page 8, line 122).

2. For a longitudinal study, a linear mixed model or a generalized estimating equations (GEE) approach is recommended. Both within-group and between-group comparisons can be performed in a single model. GEE can accommodate non-normal outcomes, and baseline values can be adjusted as covariates. Linear mixed/GEE models also handle data that are missing at random reasonably well. T-tests use less data with reducing statistical power. Consult a statistician especially for the primary analysis.

: We thank the reviewer for this comment. We would like to clarify that between-group comparisons for all efficacy outcomes were performed using analysis of covariance (ANCOVA) adjusting for baseline value and clinical trial site — not t-tests as you may have inferred. We have revised the Statistical Analysis subsection to state this explicitly (page 13, line 253). In addition, as suggested, we performed a post-hoc sensitivity analysis of the primary endpoint (change in tear volume) using a mixed model for repeated measures (MMRM), incorporating treatment, visit, and treatment-by-visit interaction as fixed effects and site and baseline value as covariates. The MMRM results were consistent with the pre-specified ANCOVA findings of comparable efficacy between SCAI-001 and Restasis. The MMRM results are presented in S3 Appendix and added to the revised manuscript (page 15, line 286).

3. Present a table showing baseline values and change from baseline at each time point, at least for the primary outcome. P-values may need adjustment for secondary outcomes.

: We have added a new table (Table 2) presenting baseline values, values at each post-baseline visit (Weeks 4, 8, and 12), and the corresponding change from baseline for the primary endpoint (Schirmer's test) in each treatment group. Values for all secondary endpoints (corneal staining, conjunctival staining, TBUT, SPEED, and OSDI) are now provided in S4 Appendix. As this was a Phase 2 exploratory study, no adjustment for multiplicity was pre-specified for secondary endpoints (Protocol Section 11.2.5), and p-values for these outcomes should be interpreted as exploratory (page 14, line 258).

4. What was the block size used for randomization?

: Participants were randomized in a 1:1:1 ratio with variable block size of 6 and 9. It is added to Study protocol subsection (page 9, line 161).

5. Table 1 should assess balance across all three groups, not only treatment vs control. There is no need to label the statistical method in the p-value column; instead, specify the methods in the Statistical Analysis section (e.g., continuous variables were compared using t-tests and categorical variables using chi-square tests).

: We revised Table 1 to compare baseline characteristics across all three treatment groups simultaneously and moved the statistical test labels from the p-value column to the Statistical Analysis section, as suggested.

6. In Figure 1, “Safety” should replace “Saftey.” Replace “Safety Set” with “FAS,” and omit “Excluded from the FAS n=0.” There is no need to show safety set in the flow diagram.

: We have revised Figure 1 accordingly.

7. In addition, the exclusion criteria for the PPS are unclear. For example, is use of a contraindicated drug considered a compliance issue or a protocol deviation/violation also?

We clarify that compliance is defined by dosing adherence rate, and is therefore distinct from contraindicated drug use. The apparent overlap arose because "Protocol deviation/violation" in Figure 1 was missing the word "Other," implying it could include contraindicated drug use as well. We have corrected this to "Other protocol deviation/violation" to clarify that these are separate, non-overlapping exclusion categories.

8. Clarify the reasons for dropouts (e.g., lack of efficacy vs safety-related reasons).

: Of the 8 dropouts, one was attributable to a drug-related adverse event; four were due to voluntary withdrawal of consent; three were due to protocol-related reasons—including use of a prohibited concomitant medication (antihistamine), prior use of cyclosporine eye drops within the screening exclusion window found out after randomization, and incomplete screening laboratory tests—none related to lack of efficacy. This clarification has been added to the S2 Appendix.

Reviewer #2: The manuscript entitled “Comparative study on the clinical effectiveness of low-concentration cyclosporine eye drops in patients with dry eye syndrome” addresses a clinically relevant question regarding whether lower-concentration nanoparticle-based cyclosporine formulations can provide comparable efficacy and tolerability to conventional cyclosporine 0.05% emulsion in dry eye syndrome. The multicenter, randomized, double-blind design is a strength, and the topic is potentially valuable. However, the present manuscript requires several important corrections before it can be considered acceptable. I recommend minor revision, provided that the authors address the following points rigorously.

1. First, the trial-registration timing must be clarified transparently. The manuscript states that recruitment began on 4 January 2023 and that ClinicalTrials.gov registration was first posted on 17 February 2023. This raises concern that the trial may have been registered after participant recruitment had already started. The authors must explicitly state whether registration was prospective or retrospective, whether the protocol was finalized before enrollment, and whether any outcomes were changed after enrollment began.

: This study was conducted as an MFDS-authorized clinical trial in Korea. Prior to enrollment of the first participant, the study protocol, informed consent form, and related study documents were reviewed and approved by both the Ministry of Food and Drug Safety (MFDS) and the Institutional Review Board (IRB). The study objectives, eligibility criteria, endpoints, and statistical analysis plan were finalized before participant enrollment commenced.

Although the ClinicalTrials.gov record was first posted on 17 February 2023, after enrollment had begun on 4 January 2023, registration on ClinicalTrials.gov was not a regulatory requirement for conduct of this trial in Korea. The study was registered to enhance transparency and public accessibility of trial information.

Importantly, no changes were made to the study objectives, primary endpoint, secondary endpoints, eligibility criteria, or statistical analysis plan after participant enrollment began. The timing of the ClinicalTrials.gov posting did not reflect any modification of the study design or outcome measures. This clarification has been added to the Study design section of the revised manuscript (page 8, line 132).

2. Second, the interpretation of efficacy is too favorable relative to the actual primary endpoint. The primary endpoint was change in tear volume at 12 weeks, and although all groups improved from baseline, there were no significant intergroup differences. Therefore, the conclusion should not imply superiority of SCAI-001. The authors should state clearly that SCAI-001 showed comparable efficacy to Restasis, while the earlier 4-week tear-volume improvement was exploratory and not supported by significant between-group difference.

We thank the reviewer for this important observation. We have revised the Abstract and Discussion to state clearly that SCAI-001 demonstrated efficacy comparable to Restasis, and that the earlier tear-volume improvement observed at 4 weeks was a secondary, exploratory finding not supported by a statistically significant between-group difference (page 19, line 360), (page 23, line 452).

3. Third, the statistical analysis requires clearer correction for multiplicity. The manuscript reports many secondary outcomes across multiple time points, including Schirmer’s test, corneal staining, conjunctival staining, TBUT, SPEED, and OSDI at 4, 8, and 12 weeks. Without adjustment for multiple comparisons, isolated findings such as better conjunctival staining with SCAI-001 0.01% at weeks 4 and 8 may be false-positive. The authors should clarify whether multiplicity adjustment was planned or explicitly label these findings exploratory.

As this was an exploratory Phase 2 trial, no multiplicity adjustment was applied across secondary endpoints and time points, per the pre-specified statistical analysis plan (Protocol Section 11.2.5). All secondary endpoint findings should therefore be interpreted as exploratory rather than confirmatory. This clarification has been added to Statistical analysis section of the revised manuscript (page 14, line 256).

4. Fourth, the handling of missing data and attrition requires more detailed justification. Of 116 randomized participants, only 96 completed the study and were included in the per-protocol set. The authors used last observation carried forward for missing efficacy endpoints. This approach can bias treatment-effect estimation in dry eye trials with fluctuating symptoms. The authors should provide reasons for withdrawal by group, compare baseline features of completers and non-completers, and add sensitivity analyses using available-case or mixed-model methods.

: We thank the reviewer for this comment. Reasons for withdrawal, baseline comparisons between completers and non-completers, and a sensitivity analysis using available cases are now provided in S2 Appendix. No significant baseline differences were observed between completers and non-completers, and the sensitivity analysis showed no meaningful differences from the primary analysis (page 14, line 270).

5. Fifth, the conflict-of-interest and funding statements require careful revision. The submission form states that SCAI Therapeutics supported the study and had a role in study design, data collection, and analysis, yet the competing-interest statement says that no competing interests exist. This is not sufficiently transparent. The authors should explicitly disclose sponsor involvement in trial design, product supply, data management, statistical analysis, manuscript preparation, and publication decisions, and clarify whether any authors received payment, consulting support, or institutional funding.

: We thank the reviewer for pointing out this inconsistency between the funding disclosure and the competing-interest statement. It is revised as follows.

- Competing Interests : The authors declare no personal competing interests. No authors received personal payments, or other financial compensation from SCAI Therapeutics in relation to this study.

- Funding statement : SCAI Therapeutics funded the study and provided the investigational product. Research funding was provided to the participating institutions to support study conduct in accordance with the clinical trial agreement. The sponsor participated in study design, data collection oversight, data management, and statistical analysis. However, SCAI Therapeutics did not participate in manuscript drafting or preparation. The authors retained responsibility for data interpretation and the decision to submit the manuscript for publication.

Changes in competing interests is provided in the comment field, as the "Competing Interests" section of the submission form was not editable.

6. Sixth, the manuscript would benefit from more comprehensive contextualization within the current dry eye disease treatment landscape. Several relevant systematic reviews and meta-analyses addressing topical therapy, ocular surface management, and adjunctive dry eye interventions should be considered to strengthen the Introduction and Discussion. The following listed 4 studies are very helpful to consider for citation: 1. PMID: 40679590; DOI: 10.1007/s00210-025-04454-8, because it directly compares topical ophthalmic drugs for keratoconjunctivitis sicca and is highly relevant to positioning cyclosporine among current pharmacologic options; 2. PMID: 40393913; DOI: 10.1016/j.clae.2025.102438, because punctal plugs are a commonly used non-pharmacologic strategy and provide broader context for tear-volume improvement in dry eye disease; 3. PMID: 40352434; DOI: 10.1177/25158414251338775, because thermal pulsation therapy is relevant to meibomian gland dysfunction-associated dry eye and helps contextualize non-immunomodulatory treatment approaches; and 4. PMID: 40204900; DOI: 10.1038/s41433-025-03790-6, because botulinum toxin A represents an emerging dry eye intervention and broadens the discussion of current and developing therapeutic strategies.

: We thank the reviewer for this valuable suggestion. We have added a citation to the Introduction (page 6, line 85).

Overall, this manuscript addresses an important therapeutic question and provides useful randomized clinical data. However, the authors must correct the trial-registration transparency issue, moderate efficacy claims, address multiplicity, clarify attrition and missing-data handling, and improve disclosure of sponsor involvement. After these minor but necessary revisions, the manuscript can be accepted for publication.

Reviewer #3:

1. Missing data on baseline dry eye severity. Please supplement this part of the results. Baseline imbalance could confound results.

: We have added new tables (Table 2 and S4 appendix) presenting baseline values.

2. In this Clinical Trial, the primary efficacy endpoint was the change in tear volume after 12 weeks. While, as we all known, the Schirmer test, with poor reproducibility and high stimulation effect, has a high coefficient of variation, is of limited clinical relevance compared to objective signs like corneal staining and BUT. Please explain the reason for using tear volume as the primary efficacy endpoint.

: We appreciate the reviewer's insightful comment regarding the choice of primary efficacy endpoint. We acknowledge that Schirmer's test is known to have relatively high inter-individual and intra-individual variability.

However, tear volume was selected as the primary endpoint for the following reasons. First, this design followed regulatory and academic precedent set by cyclosporine-class ophthalmic formulations. Restasis® (cyclosporine 0.05%) was approved by FDA in 2003 based on a statistically significant improvement in tear production measured by Schirmer’s test (De Oliveira et al., Clin Ophthalmol 2019). This same endpoint design was subsequently adopted as the sole primary efficacy endpoint in the phase 3 trial of OTX-101 (cyclosporine ophthalmic solution 0.09%, approved by the FDA in 2018 as Cequa®), in which a significantly greater proportion of eyes achieved improvement in Schirmer's test score (Goldberg et al., Ophthalmology 2019).

Second, SCAI-001 was developed with the primary mechanistic goal of enhancing corneal penetration and normalizing sensory nerve signaling to the lacrimal gland, thereby increasing quantitative tear secretion; tear volume change is therefore the endpoint most directly aligned with this proposed mechanism of action.

We have added a statement regarding this point as limitations in discussion section and noting it as a consideration for future trial design (page 22, line 440).

3. As authors has mentioned in the introduction, SCAI eye drops (0.01% and 0.02% cyclosporine) with lower concentrations, aiming to alleviate discomfort such as ocular irritation and foreign body sensation caused by the formulation of conventional cyclosporine eye drop such as 0.05% cyclosporine (Restasis, Allergan Inc.). While, safety outcomes showed that in the ocular tolerability evaluation, no differences were determined in the severity scores of the seven symptoms between the study and control groups. Does this result deviate from the main purpose of the innovative low concentration cyclosporine eye drops?

: We thank the reviewer for this insightful and

Attachment

Submitted filename: Response to Reviewers.docx

pone.0358007.s010.docx (28.5KB, docx)

Decision Letter 1

Kofi Asiedu

25 Aug 2026

Comparative study on the clinical effectiveness of low-concentration cyclosporine eye drops in patients with dry eye disease

PONE-D-25-46652R1

Dear Dr. Lee,

We’re pleased to inform you that your manuscript has been judged scientifically suitable for publication and will be formally accepted for publication once it meets all outstanding technical requirements.

Within one week, you’ll receive an e-mail detailing the required amendments. When these have been addressed, you’ll receive a formal acceptance letter and your manuscript will be scheduled for publication.

An invoice will be generated when your article is formally accepted. Please note, if your institution has a publishing partnership with PLOS and your article meets the relevant criteria, all or part of your publication costs will be covered. Please make sure your user information is up-to-date by logging into Editorial Manager at Editorial Manager® and clicking the ‘Update My Information' link at the top of the page. For questions related to billing, please contact billing support.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they’ll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

Kind regards,

Kofi Asiedu, O.D., Ph.D. FAAO

Academic Editor

PLOS One

Additional Editor Comments (optional):

Reviewers' comments:

Reviewer's Responses to Questions

Comments to the Author

Reviewer #1: All comments have been addressed

**********

2. Is the manuscript technically sound, and do the data support the conclusions??>

Reviewer #1: (No Response)

**********

3. Has the statistical analysis been performed appropriately and rigorously? -->?>

Reviewer #1: (No Response)

**********

4. Have the authors made all data underlying the findings in their manuscript fully available??>

The PLOS Data policy

Reviewer #1: (No Response)

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: (No Response)

**********

Reviewer #1: (No Response)

**********

what does this mean?). If published, this will include your full peer review and any attached files.

If you choose “no”, your identity will remain anonymous but your review may still be made public.

Do you want your identity to be public for this peer review?  For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

**********

Acceptance letter

Kofi Asiedu

PONE-D-25-46652R1

PLOS One

Dear Dr. Lee,

I'm pleased to inform you that your manuscript has been deemed suitable for publication in PLOS One. Congratulations! Your manuscript is now being handed over to our production team.

At this stage, our production department will prepare your paper for publication. This includes ensuring the following:

* All references, tables, and figures are properly cited

* All relevant supporting information is included in the manuscript submission,

* There are no issues that prevent the paper from being properly typeset

You will receive further instructions from the production team, including instructions on how to review your proof when it is ready. Please keep in mind that we are working through a large volume of accepted articles, so please give us a few days to review your paper and let you know the next and final steps.

Lastly, if your institution or institutions have a press office, please let them know about your upcoming paper now to help maximize its impact. If they'll be preparing press materials, please inform our press team within the next 48 hours. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact onepress@plos.org.

You will receive an invoice from PLOS for your publication fee after your manuscript has reached the completed accept phase. If you receive an email requesting payment before acceptance or for any other service, this may be a phishing scheme. Learn how to identify phishing emails and protect your accounts at https://explore.plos.org/phishing.

If we can help with anything else, please email us at customercare@plos.org.

Thank you for submitting your work to PLOS One and supporting open access.

Kind regards,

PLOS One Editorial Office Staff

on behalf of

Dr. Kofi Asiedu

Academic Editor

PLOS One

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Appendix. Exclusion criteria for the randomized controlled trial.

    (DOCX)

    pone.0358007.s001.docx (14.4KB, docx)
    S2 Appendix. Reason for withdrawal by treatment group, comparison of baseline characteristics between study completers and non-completers, and sensitivity analysis of the primary efficacy endpoint using a mixed-effects model for repeated measures.

    (DOCX)

    pone.0358007.s002.docx (20.2KB, docx)
    S3 Appendix. Sensitivity analysis of change in tear volume by Schirmer’s test from baseline using a mixed model for repeated measures.

    (DOCX)

    pone.0358007.s003.docx (21.3KB, docx)
    S4 Appendix. Baseline values and change from baseline for secondary efficacy endpoints by visit and treatment group.

    (DOCX)

    pone.0358007.s004.docx (18.4KB, docx)
    S1 Checklist. CONSORT checklist.

    (DOCX)

    pone.0358007.s005.docx (34.7KB, docx)
    S1 Fig. CONSORT flow diagram of study participants.

    (DOCX)

    pone.0358007.s006.docx (64.1KB, docx)
    S1 Protocol. Study protocol.

    (PDF)

    pone.0358007.s007.pdf (1.6MB, pdf)
    S1 Dataset. Study dataset.

    (ZIP)

    Attachment

    Submitted filename: Response to Reviewers.docx

    pone.0358007.s010.docx (28.5KB, docx)

    Data Availability Statement

    All relevant data are within the paper and its Supporting information files.


    Articles from PLOS One are provided here courtesy of PLOS

    RESOURCES