Skip to main content
Journal of Hip Preservation Surgery logoLink to Journal of Hip Preservation Surgery
. 2026 Oct 5;13(Suppl 1):i25. doi: 10.1093/jhps/hnag043.056

FP7.8 MRI vs CT for acetabular and femoral morphology in the diagnosis and surgical planning for acetabular dysplasia

Dr David Liu 1, Miles Batty 2, Mahdi Aghaalikhani 3, Shanika De Silva 4, Yi-Meng Yen 5, Young-Jo Kim 6, Mohammadreza Movahhedi 7, Ata Kiapour 8
PMCID: PMC13636997

Abstract

ICLB07 - The Digital Surgeon: Practical Tools and Navigation Basics for Your Everyday Practice, Session Room 12 (BMCC Level 3), October 8, 2026, 14:00 - 16:00

Introduction

Computed tomography (CT) is considered the standard of care for three-dimensional modeling and surgical planning in acetabular dysplasia. However, CT poses significant radiation risks towards an at-risk young population, as well as inability to assess soft tissue pathology. As such, additional magnetic resonance imaging (MRI) is often necessary for complete workup. We hypothesize that MRI provides equivalent morphological measurements compared to CT.

Methods

Following IRB approval, we retrospectively analyzed 45 consecutive patients with acetabular dysplasia who underwent both CT and MRI as part of pre-operative planning ahead of hip preservation surgery. For both CT and MRI, imaging through the distal femur was required for femoral version measurement. All CTs included the entire pelvis, whereas some MRIs did not include the full pelvis. A custom-developed and validated program (VirtualHip, Boston Children’s Hospital) was used to automatically segment bones, identify landmarks, define anatomical coordinate systems, and measure anatomical features. Key measurements included Tönnis angle, lateral center-edge angle, acetabular version, femoral version, and femoral head coverage. CT was treated as the reference standard. Mean absolute differences between MRI and CT were calculated for each variable. Paired t-tests and non-inferiority testing (with a clinical margin of error set to 5° or 5%) were performed to assess agreement.

Results

The generated 3D models from CT and MRIs were comparable (error <0.5mm). Mean absolute differences were within ±5° or ±5%, including femoral version (bias +2.5° Reikeras; +1.8° Murphy), LCEA at 12:00 (bias +3.8°), acetabular version (bias +5.0°), Tonnis angle (+3.2°). Femoral head coverage differed by <0.1% overall. No differences were statistically significant (p>0.05). Acetabular measurements demonstrated slightly higher discrepancy; however, in patients where the full pelvis was included in the available MRI, the magnitude of discrepancy was lower.

Discussion

MRI provides accurate, non-inferior 3D measurements of acetabular and femoral morphology compared to CT in patients with acetabular dysplasia. In addition to eliminating radiation exposure, MRI allows for evaluation of soft tissues including labrum, cartilage, and capsule that CT cannot assess. These findings support the role of MRI that captures the full pelvis with extension to the knee as a standalone imaging modality for diagnosis and surgical planning in acetabular dysplasia.

Clinical Reference

This study supports substituting CT with MRI for preoperative assessment in acetabular dysplasia. MRI offers comparable accuracy for 3D bone measurements, with added soft tissue detail and no radiation exposure – potentially changing standard imaging protocols in this young, at-risk population.


Articles from Journal of Hip Preservation Surgery are provided here courtesy of Oxford University Press