Abstract
Background
Accurate assessment of the His–ventricular (HV) interval is essential to diagnosing infranodal conduction disease, but the influence of recording site and sex on HV values is not well defined.
Objective
To evaluate the impact of measurement location and sex on HV interval values using high-density (HD) mapping catheters in patients undergoing atrial fibrillation (AF) ablation.
Methods
We prospectively studied patients in sinus rhythm undergoing AF ablation. HV intervals were measured with a decapolar catheter and a HD mapping catheter at the end of the procedure. HD-based HV intervals were classified as proximal (HVprox), distal (HVdis), and right bundle (HVRB) recordings. Conduction velocities and sex-specific differences were analyzed.
Results
A total of 67 patients (mean age 64 ± 10 years, 33%women) were evaluated. The clinical HV interval was 45 ± 9 ms and shorter in women (40 ms vs. 47 ms, p < 0.001). HVprox was longer than HVdis (51 ± 10 ms vs. 46 ± 10 ms, p < 0.001) and HVRB (37 ± 10 ms; p < 0.001). Abnormal HV intervals (> 55 ms) were more often detected using HVprox than HVdis or HVRB. Conduction velocities did not differ by sex and correlated poorly with surface ECG parameters.
Conclusion
HV interval measurements vary significantly by recording site and sex. Proximal measurements reveal longer HV intervals and detect more conduction delays, while women have systematically shorter HV intervals. Anatomical precision and sex-specific interpretation are important for accurate diagnosis of infranodal conduction delay.
Graphical Abstract
Abbreviations: Dis: Distal His-Ventricle measurement, Prox: Proximal His-Ventricle measurement, RB: His-ventricle measurement over the right bundle.

Supplementary Information
The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02438-z.
Keywords: His-Ventricle Interval, His Cloud, His Bundle Electrogram
What is new?
HV interval measurements differ significantly by recording site, with proximal high-density mapping catheter recordings yielding longer intervals and identifying more patients with abnormal conduction than distal recordings.
Women exhibit consistently shorter HV intervals than men, across all measurement locations, emphasizing the need for sex-specific reference values in conduction assessment.
Standard clinical HV measurements closely reflect distal values, potentially underestimating conduction delay and influencing pacemaker decision-making.
Supplementary Information
The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02438-z.
Introduction
Accurate evaluation of infrahisian conduction is crucial for risk stratification in patients with suspected infranodal conduction disease across various clinical scenarios. The 2021 ESC Guidelines on Cardiac Pacing [1] recommend measurement of the His–ventricular (HV) interval in patients with unexplained syncope and bundle branch block, neuromuscular disorders with conduction abnormalities, or persistent conduction disturbances following TAVI, to detect infranodal conduction delay and inform decisions regarding permanent pacemaker implantation.
According to current guidelines, an HV interval < 55 ms is considered normal, > 55 ms abnormal, and ≥ 70 ms as typically warranting pacemaker implantation, especially in symptomatic individuals or those with high-risk features [2, 3]. Nonetheless, several studies reported that these cut-offs may not account for sex differences as women were shown to have shorter HV intervals than men [4–8].
Following the protocols of Josephson [9] and Zipes [10], the HV interval is measured from the earliest His bundle deflection to the onset of the QRS complex on the surface ECG. Ideally, the initial His electrogram deflection is identified by a prominent atrial electrogram; however, a prominent His deflection accompanied by a smaller atrial signal may lead to underestimation of the HV interval [11].
Although HV interval measurements can be obtained with standard quadripolar or ablation catheters, capturing the most proximal His signal is often technically demanding and time-consuming. High-density (HD) mapping catheters now allow detailed electroanatomical mapping through acquisition of large numbers of mapping points. In clinical practice, signals consistent with His electrograms are often annotated across different anatomical sites, forming a so-called "His-cloud," for instance to guide safe ablation distances. However, scientific data systematically evaluating the variation in HV interval across these His-cloud recordings are scarce.
In this study, we sought to investigate the impact of recording site and sex on HV interval measurements using a HD mapping catheter.
Methods
His-interval measurement
We included consecutive patients undergoing catheter ablation for atrial fibrillation (AF) between September 2021 and June 2023. At the end of the ablation procedure, all patients received additional His-Ventricle interval (HV) measurements using both a decapolar and a high-density mapping catheter. The HV interval was measured using a decapolar catheters with 2 mm interelectrode spacing (Biosense Webster, USA) and a multipolar high-density mapping catheter (Pentaray or Octaray) at the end of the procedure in sinus rhythm using the 3D electroanatomic local activation map (Carto 3, Biosense Webster, USA). For signal filtering, a Low Pass of 300 Hz and a High Pass of 30 Hz with a notch filter at 50 Hz were used. A sample size of at least 50 patients was targeted based on prior literature for agreement assessment (intraclass correlation coefficient).
All HV measurements were defined as the time between the onset of the intracardiac His deflection and the onset of the QRS interval on the 12-lead surface ECG with a sweep speed of 100 mm/s. The HV interval was measured with the high density mapping catheters using three different methods based on the His Bundle electrogram – a proximal measurement (HVprox defined by a large A signal, a His signal and a small V signal, see main Figure), a distal measurement (HVdis defined by a small A signal, a His signal and a V signal) and a right-bundle measurement (HVRB defined as an electrogram without A signal, a His Signal and a large V signal). These measurements were then compared to the clinical HV interval measurement using a decapolar catheter. All measurements were performed at the end of the procedure in sinus rhythm.
The conduction speed through the various segments of the His bundle was calculated using the distance between the measurement locations and the difference in conduction time of the 3D electroanatomic activation map.
Finally, the agreement in HV interval measurements was calculated, between the HVprox from the high-density mapping catheter and the intraprocedural clinical HV measurement.
All measurements and tests were evaluated for male and female participants separately.
Statistical methodology
Continuous variables were summarized by means (standard deviation – SD) or medians (interquartile range – [IQR]) and were subjected to appropriate statistical tests based on the data distribution. Specifically, the Student's t-test and Mann–Whitney U test were utilized for comparisons, depending on the data's distribution characteristics. Paired data was assessed using either the paired versions of the t-test or the Wilcoxon signed-rank test, contingent upon the data distribution.
Categorical data underwent evaluation employing the Chi-squared test or Fischer test, as deemed suitable. Correlation analyses employed either Pearson's or Spearman's correlation coefficient, depending on the data distribution. Two complementary models were used. First, a multivariable linear regression analyzed the clinical (decapolar) HV interval — a single measurement per patient — adjusted for prespecified covariables (age, sex, coronary heart disease, hypertension, diabetes, body surface area, atrial fibrillation type, and rhythm at presentation); the outcome was log-transformed due to right-skew, and coefficients are reported as exponentiated (relative) effects. Second, because each patient contributed four HV measurements (clinical, proximal, distal and right bundle), the comparison across recording sites was performed with a linear mixed-effects model including a random intercept per patient to account for the within-patient correlation of repeated measurements; recording site was entered as a four-level fixed factor (clinical HV as reference), adjusted for the same prespecified covariables.
Sex-specific effects were assessed by including sex × recording-site (for the HV interval) and sex × segment (for conduction velocity) interaction terms in the mixed-effects models.
Measurement consistency with a decapolar catheter and the multipolar catheter in measuring the HV interval was assessed using the intraclass correlation coefficient with a two-way random-effects model, employing the average of all measurements and by Pearson’s R and R squared. The results were visually depicted through a Bland–Altman plot. Statistical significance was established at a P-value of 0.05. All statistical analyses were conducted using R version 4.2.1 (Vienna, Austria).
Results
A total of 67 patients (mean age 64 ± 10 years, 33% women) were evaluated. An overview of the baseline characteristics is presented in Table 1. Compared with men, women had lower rates of hypertension, shorter P-wave duration on surface ECG, and a different distribution of atrial fibrillation.
Table 1.
Baseline Characteristics
| Variable | Overall, N = 671 | Sex | p-value2 | |
|---|---|---|---|---|
| female, N = 221 | male, N = 451 | |||
| Age, years | 64 (10) | 66 (12) | 63 (10) | 0.33 |
| Body Surface Area, m2 | 2.1 (0.2) | 1.9 (0.2) | 2.2 (0.2) | < 0.001 |
| Arterial Hypertension, n% | 42 (63%) | 9 (41%) | 33 (73%) | 0.010 |
| Diabetes, n% | 7 (10%) | 1 (4.5%) | 6 (13%) | 0.41 |
| Coronary Heart Disease, n% | 13 (19%) | 2 (9.1%) | 11 (24%) | 0.19 |
| Chronic Kidney Disease, n% | 6 (9.0%) | 1 (4.5%) | 5 (11%) | 0.66 |
| Hyperthyroidism, n% | 2 (3.0%) | 1 (4.5%) | 1 (2.2%) | > 0.99 |
| Hypothyroidism, n% | 6 (9.0%) | 3 (14%) | 3 (6.7%) | 0.39 |
| Atrial Flutter, n% | 7 (10%) | 1 (4.5%) | 6 (13%) | 0.41 |
| Paroxysmal Atrial Fibrillation, n% | 27 (41%) | 15 (68%) | 12 (27%) | 0.001 |
| CHA2DS2–VA Score | 2 (1.6) | 1.8 (1.6) | 2.1 (1.6) | 0.077 |
| Rhythm Before EP Study | < 0.001 | |||
| Atrial Fibrillation, n% | 25 (37%) | 2 (9.1%) | 23 (51%) | |
| Atrial Flutter, n% | 2 (3.0%) | 0 (0%) | 2 (4.4%) | |
| Sinus Rhythm, n% | 40 (60%) | 20 (91%) | 20 (44%) | |
| P Wave Duration, ms | 125 (27) | 115 (27) | 131 (26) | 0.033 |
| PR Interval, ms | 168 [133–205] | 148 [128–174] | 179 [143–206] | 0.055 |
| QRS Duration, ms | 100 [94–150] | 95 [90–142] | 102 [94–152] | 0.15 |
| QT Interval, ms | 410 [382–438] | 420 [386–440] | 410 [380–434] | 0.82 |
| Class I c AAD | 3 (4.5%) | 1 (4.5%) | 2 (4.5%) | 0.99 |
| Class II AAD | 43 (65%) | 14 (64%) | 29 (66%) | 0.99 |
| Class III AAD | 13 (20%) | 3 (14%) | 10 (23%) | 0.52 |
1Mean (SD), Median [IQR] or Frequency (%) 2Welch Two Sample t-test; Pearson's Chi-squared test; Fisher's exact test; Wilcoxon rank sum test
Abbreviations: AAD – antiarrhythmic drug, EP – electrophysiological, IQR – Interquartile range, SD – standard deviation
The HV interval measured with a decapolar catheter (clinical HV interval) was 45 ± 9 ms overall, but significantly shorter in women than in men (40 ms vs 47 ms, p < 0.001). This sex difference was attenuated after multivariable adjustment for age, body surface area, coronary artery disease, diabetes, hypertension, type of atrial fibrillation and rhythm at presentation (p = 0.04).
His-cloud measurements
Using the HD mapping catheter, the mean proximal HV (HVprox) was 51 ± 10 ms, with significantly shorter values in women compared to men (48 ± 9 ms vs. 53 ± 10 ms, p = 0.03). The mean distal HV interval (HVdis) was 46 ± 10 ms (42 ± 8 ms in women vs. 48 ± 10 ms in men, p = 0.005). On average, HVprox exceeded HVdis by 5.1 ± 3 ms (women: 5.9 ± 3.5 ms; men: 4.7 ± 2.6 ms, p = 0.15) (Table 2).
Table 2.
His-Cloud Measurements
| Variable | Overall, N = 671 | Sex | p-value2 | |
|---|---|---|---|---|
| female, N = 221 | male, N = 451 | |||
| Proximal HV Interval, ms | 51 (10) | 48 (9) | 53 (10) | 0.034 |
| Distal HV Interval, ms | 46 (10) | 42 (8) | 48 (10) | 0.005 |
| HV with Right Bundle Signal, ms | 37 (10) | 33 (8) | 40 (10) | 0.002 |
| HV Delta Proximal–Distal, ms | 5.1 (3.0) | 5.9 (3.5) | 4.7 (2.6) | 0.15 |
| HV Delta Distal-RB, ms | 8.4 (5.1) | 8.9 (5.5) | 8.2 (4.9) | 0.65 |
| Overall Propagation Speed, m/s | 1.5 (0.6) | 1.4 (0.6) | 1.5 (0.6) | 0.59 |
| Proximal Propagation Speed, m/s | 1.8 (1.0) | 1.6 (0.9) | 1.8 (1.0) | 0.43 |
| Distal Propagation Speed, m/s | 1.4 (0.7) | 1.5 (0.8) | 1.4 (0.6) | 0.61 |
1Mean (SD), Median [IQR] or Frequency (%) 2Welch Two Sample t-test
Abbreviations: HV- His-ventricle, RB – right bundle, SD – standard deviation
When measured over the right bundle (HVRB), the HV interval was significantly shorter, with a mean of 37 ± 10 ms (women: 33 ± 8 ms, men: 40 ± 10 ms, p = 0.002). Compared to HVdis, HVRB was on average 8.4 ± 5.1 ms shorter (women: 8.9 ± 5.5 ms, men: 8.2 ± 4.9 ms, p = 0.65). Differences in HV interval duration by measurement site and sex are visualized in the split violin plot (Fig. 1). Using linear mixed-effects models the differences between the four types of HV interval measurements remained statistically different after multivariable adjustment for age, sex, body surface area, hypertension, coronary artery disease, diabetes, type of atrial fibrillation and rhythm at presentation (Fig. 2).
Fig. 1.

Split Violin Plot of the HV interval in female (green) vs male(orange) patients in various catheter mapping positions. Proximal HV measurement (left) are significantly longer than the distal and Right Bundle measurements. Regardless of catheter position, the HV interval is always longer in men. Abbreviations: HV – His-Ventricle, RB – Right Bundle
Fig. 2.

Coefficient plot from a linear mixed-effects model showing the relative effects of measurement methods and clinical covariates on HV interval, with firebrick indicating measurement method estimates compared to clinical HV interval, and black for covariate effects; error bars represent 95% confidence intervals
Clinically, measurement location impacted the detection of prolonged HV intervals. Using the proximal site, 19 patients (28%) had abnormal HV intervals > 55 ms, compared to 8 patients (12%) using distal measurements and only 3 patients (5%) using right bundle recordings. Notably, two patients had HV intervals ≥ 70 ms (proximal and distal). Sensitivity analyses excluding patients with thyroid disorders, as well as an analysis accounting for antiarrhythmic treatment revealed similar results.
The conventional decapolar measurement most closely matched the distal His recording (mean difference 1.3 ms) and underestimated the proximal HV by 6.3 ms (95% CI 4.8–7.9). Relative to the proximal recording, a distal signal was on average 5.1 ms shorter (95% CI 4.4–5.8) and a right-bundle signal 13.5 ms shorter (95% CI 12.2–14.9).
His bundle propagation speed
The overall propagation speed from the proximal His recording site to the right bundle location was 1.5 ± 0.6 m/s, with no significant difference between sexes (women: 1.4 ± 0.6 m/s vs. men: 1.5 ± 0.6 m/s, p = 0.6). Sex-stratified differences in propagation times between His bundle recording sites are shown in Fig. 3.
Fig. 3.

The conduction speed in the proximal portion of the His bundle seems to be higher on average compared to the distal portion. In men, this difference is significant, while in women the conduction speed is more uniform
Estimated conduction velocity between the proximal and distal His bundle locations were 1.8 ± 1.0 m/s (women: 1.6 ± 0.9 m/s, men: 1.8 ± 1.0 m/s, p = 0.43). From the distal His to the right bundle, propagation speed was slightly lower at 1.4 ± 0.7 m/s (women: 1.5 ± 0.8 m/s, men: 1.4 ± 0.6 m/s, p = 0.6). In men, the distal conduction velocity was significantly slower than the proximal (1.4 ± 0.6 m/s vs. 1.8 ± 1.0 m/s, p = 0.005), whereas in women no significant difference was observed (1.5 ± 0.8 m/s vs. 1.6 ± 0.9 m/s, p = 0.63), however the interactions between sex and conduction velocity overall and within segments were not statistically significant (Supplement).
Correlation analysis revealed that overall, His propagation speed showed weak correlation with the surface ECG: P wave duration (R = –0.30, p = 0.02), PR interval (R = –0.23, p = 0.07), QRS duration (R = 0.20, p = 0.14), QT interval (R = 0.05, p = 0.70). No other baseline clinical parameters were associated with propagation speed.
Agreement in HV interval measurements
The proximal HV was measured in all patients with two catheters, a decapolar catheter and a high-density mapping catheter. The mean HV interval measured 45 ± 9 ms using a decapolar catheter (i.e., the clinical HV measurement) and 51 ± 10 ms with a high-density mapping catheter, respectively (mean difference -6 ms, 95% limits of agreement -19, 6 ms, ppaired T-test < 0.001). In women, the mean difference in measurements were slightly higher at -8 ms vs -6 ms in male (p = 0.18). Male patients demonstrated excellent agreement between methods (ICC 0.92; 95% CI, 0.85—0.95), while in female patients the agreement was good (ICC 0.72; 95% CI, 0.33—0.88). In patients with cardiovascular risk factors, agreement between the two measurement methods was excellent (ICC = 0.91; 95% CI, 0.85—0.95) but was moderate in case of patients without cardiovascular risk factors (ICC = 0.54; 95% CI, –0.13—0.82). The differences between measurements are illustrated in the Bland-Altmann plot (Fig. 4). Pearson’s correlation coefficient was R = 0.79 and the reliability coefficient was R2 = 0.62, p < 0.001.
Fig. 4.

Bland Altmann Plot showing the variation of the HV interval measurements between the two catheters dependent on sex
Discussion
In this study, we systematically evaluated the variability of HV interval measurements using a HD mapping catheter, focusing on the impact of measurement location and sex. We found that proximal HV intervals, in accordance with the definitions by Josephson [9] and Zipes [10], were on average 11% longer than distal HV intervals and 38% longer than right bundle measurements. Notably, the clinical HV interval recorded in clinical practice, closely mirrored the distal measurement, suggesting that standard HV interval measurements may underestimate conduction delay, especially when measured distally. Abnormal HV intervals > 55 ms were measured in 28% using proximal recording compared with only 12% using distal recordings, underscoring the importance of proximal HV measurements to avoid misclassification of conduction disease.
Several additional observations emerged from our analysis: First, we observed important sex-specific differences: Across all measurement sites (proximal, distal, and over the right bundle) women consistently exhibited shorter HV intervals than men. While overall His-bundle propagation velocity was similar between sexes, men demonstrated a significant drop in conduction speed from proximal to distal, a finding requiring further validation in larger cohorts. Second, His-bundle propagation velocity correlated poorly with any of the ECG parameters and baseline parameters with only the P wave duration showing a modest correlation (R = –0.30, p = 0.02).
Our findings emphasize the importance of both sex-specific reference values and the anatomical measurement site in accurately diagnosing His–Purkinje conduction disease. If the HV interval is measured too distally, clinically relevant conduction delays may be overlooked, especially in women who inherently present with shorter HV intervals [4, 5]. This observation aligns with earlier studies suggesting potential sex-related differences in cardiac conduction [4, 5, 12–14], possibly driven by variations in heart size [15], myocardial fibrosis, or ion channel distribution [6, 7]. Because women exhibit a systematically lower baseline HV, a single fixed 55 ms cutoff represents a higher relative threshold in women and may under-detect infranodal delay in women. Consistent with this, no woman in our cohort reached the pacemaker-associated threshold of 70 ms at any recording site, and women exceeded 55 ms only with proximal recording (23%). Whether sex-adjusted reference values would alter pacemaker decision-making remains unclear.
The HV interval may also come with a risk of overdiagnosis: proximal HV interval measurements, while sensitive, may inflate the prevalence of abnormal findings, potentially prompting unwarranted pacemaker implantation in borderline cases [16–18]. The clinical implications of overdiagnosis are substantial, as pacemaker therapy, although effective, carries non-negligible risks, including lead dislodgement, perforation, infection and is associated with a higher overall mortality [19–22]. Thus, a balanced interpretation integrating clinical and electrophysiological data remains essential.
As a single fixed threshold has not been validated across recording sites and the definition of the HV interval implies a proximal measurement, applying the conventional cutoff to more distal recordings underestimates conduction delay. As the proximal signal may be difficult to obtain in routine practice, an electrogram-based correction toward the proximal value — approximately + 5 ms for a distal signal and + 13 ms for a right-bundle signal — may serve as a pragmatic alternative when high-density His-cloud mapping is not available or is too resource-intensive. Nonetheless, such an approach requires further validation in larger cohorts of patients.
The agreement between the two measurements showed good overall reliability in HV interval measurements, but with greater variability among patients without cardiovascular risk factors. This suggests that measurement consistency is impacted by patient characteristics, reinforcing the need for standardized approaches.
Limitations
This study has several limitations. It included only patients undergoing catheter ablation for atrial fibrillation, which may limit generalizability to the general population as atrial fibrillation may be associated with underlying atrial disease, autonomic dysfunction, structural remodelling. Propagation speed calculations relied on estimated distances and did not fully account for the 3D anatomy of Koch’s triangle. No pharmacological or pacing stress protocols were applied to assess dynamic changes in conduction. The low number of females in the study may limit the power of some sex-specific analyses and may lead to model overfitting.
Conclusion
HV interval measurements vary significantly by catheter position and sex, with proximal recordings yielding consistently longer intervals and with women showing shorter HV intervals than men across all sites. Clinicians should incorporate anatomical location, sex-specific differences, and clinical context when interpreting HV intervals. Future research should focus on standardizing HV measurement protocols to optimize diagnostic accuracy and minimize both under- and overtreatment.
Supplementary Information
Below is the link to the electronic supplementary material.
Author Contribution
T.S. wrote the main manuscript text and statistical analysis, did the manuscript revision, J.D.F. statistical analysis review and manuscript review, P.B. prepared the main figure and overviewed the study. All authors contributed to data gathering and reviewed the manuscript.
Funding
Open access funding provided by University of Basel. None.
Data availability
No datasets were generated or analysed during the current study.
Declarations
Disclosures
Teodor Serban has received research funding from the 'Swiss Academy of Medical Sciences' and the ‘Gottfried & Julia Bangerter-Rhyner’ Foundation. Philipp Krisai reports speaker fees from BMS/Pfizer. Sven Knecht has received funding from the 'Swiss Heart Foundation'. Felix Mahfoud has been supported by Deutsche Forschungsgemeinschaft (SFB TRR219, Project-ID 322900939), and Deutsche Herzstiftung. Saarland University has received scientific support from Ablative Solutions, Medtronic and ReCor Medical. Until May 2024, Felix Mahfoud has received speaker honoraria/consulting fees from Ablative Solutions, Astra-Zeneca, Inari, Medtronic, Merck, Novartis, Philips and ReCor Medical, all outside the submitted work. Michael Kühne reports grants from the Swiss National Science Foundation (Grant numbers 33CS30_148474, 33CS30_177520, 32473B_176178, 32003B_197524), the Swiss Heart Foundation, the Foundation for Cardiovascular Research Basel and the University of Basel, grants from Bayer, grants from Pfizer, grants from Boston Scientific, grants from BMS, grants from Biotronik, grants and personal fees from Daiichi Sankyo, all outside the submitted work. Christian Sticherling is a member of the Medtronic Advisory Board Europe and Boston Scientitic Advisory Board Europe, received educational grants from Biosense Webster and Biotronik and a research grant from the European Union’s FP7 program, and Biosense Webster and lecture and consulting fees from Abbott, Medtronic, Biosense-Webster, Boston Scientific, Microport and Biotronik all outside the submitted work. Patrick Badertscher has received research funding from the 'University of Basel', the Swiss Heart Foundation and Johnson&Johnson and reports personal fees from Abbott, BMS Pfizer, Boston Scientific and Bayer, all outside the submitted work. Others have nothing to declare.
Footnotes
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Teodor Serban and Jeanne du Fay de Lavallaz should be considered shared-first authors.
References
- 1.Glikson M, Nielsen JC, Kronborg MB, Michowitz Y, Auricchio A, Barbash IM, et al. 2021 ESC guidelines on cardiac pacing and cardiac resynchronization therapy. Eur Heart J. 2021;42:3427–520. [DOI] [PubMed] [Google Scholar]
- 2.Scheinman MM, Peters RW, Morady F, Sauve MJ, Malone P, Modin G. Electrophysiologic studies in patients with bundle branch block. Pacing Clin Electrophysiol. 1983;6:1157–65. [DOI] [PubMed] [Google Scholar]
- 3.Scheinman MM, Peters RW, Sauvé MJ, Desai J, Abbott JA, Cogan J, et al. Value of the H-Q interval in patients with bundle branch block and the role of prophylactic permanent pacing. Am J Cardiol. 1982;50:1316–22. [DOI] [PubMed] [Google Scholar]
- 4.Serban T, Knecht S, Mannhart D, de Lavallaz JduF, Schwendinger R, Krisai P, et al. Sex-specific differences in HV interval in a large cohort of patients. J Interv Card Electrophysiol. 2022. 10.1007/s10840-022-01427-2. [DOI] [PubMed] [Google Scholar]
- 5.Serban T, Knecht S, Mannhart D, Nestelberger T, Kaiser C, Leibundgut G, et al. Sex-specific differences in infranodal conduction properties in patients undergoing transcatheter aortic valve replacement. J Cardiovasc Transl Res. 2023;16:968–70. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Francisco-Pascual J, Rivas-Gándara N, Bach-Oller M, Badia-Molins C, Maymi-Ballesteros M, Benito B, et al. Sex-related differences in patients with unexplained syncope and bundle branch block: lower risk of AV block and lesser need for cardiac pacing in women. Front Cardiovasc Med. 2022;9:838473. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7.Taneja T, Windhagen Manhert B, Passman Rod, Goldberger J, Kadish A. Effects of Sex and Age on Electrocardiographic and Cardiac Electrophysiological Properties in Adults. Pacing and Clinical Electrophysiology. 2001;24:16–21. [DOI] [PubMed]
- 8.Bernier R, Tran DT, Sheldon RS, Kaul P, Sandhu RK. A population-based study evaluating sex differences in patients presenting to emergency departments with syncope. JACC Clin Electrophysiol. 2020;6:341–7. [DOI] [PubMed]
- 9.Josephson M. Josephson’s clinical cardiac electrophysiology. 5th ed. Lippincott Williams and Wilkins; 2015.
- 10.Ziad I, John M, Douglas Z. Clinical arrhythmology and electrophysiology: a companion to Braunwald’s heart disease. 3rd ed. Philadelphia: Elsevier; 2019.
- 11.Alboni P, Scarfó S, Baggioni GF, Paparella N, Cappato R, Cavallesco G. Relationship between the most proximal His bundle and the morphology of intracavitary pressure curves. Eur Heart J. 1989;10:887–91. [DOI] [PubMed] [Google Scholar]
- 12.Badertscher P, Mäder N, Serban T, Nestelberger T, Leibundgut G, Kaiser C, et al. Incidence of infranodal conduction delay in patients with left bundle branch block after transcatheter aortic valve replacement: impact of the 2021 ESC guidelines for cardiac pacing. Heart Rhythm. 2021;20:646–7. [DOI] [PubMed] [Google Scholar]
- 13.Badertscher P, Knecht S, Zeljković I, Sticherling C, de Asmundis C, Conte G, et al. Management of conduction disorders after transcatheter aortic valve implantation: results of the EHRA survey. EP Europace. 2022;24:1179–85. [DOI] [PubMed] [Google Scholar]
- 14.Badertscher P, Knecht S, Spies F, Auberson C, Salis M, Jeger R V., Fahrni G, Kaiser C, Schaer B, Osswald S, et al. Value of periprocedural electrophysiology testing during transcatheter aortic valve replacement for risk stratification of patients with new‐onset left bundle‐branch block. J. Am. Heart Assoc. 2022;11. 10.1161/JAHA.122.026239 [DOI] [PMC free article] [PubMed]
- 15.Hense H-W, Gneiting B, Muscholl M, Broeckel U, Kuch B, Doering A, et al. The associations of body size and body composition with left ventricular mass: impacts for indexation in adults. J Am Coll Cardiol. 1998;32:451–7. [DOI] [PubMed] [Google Scholar]
- 16.Chokshi AB. Impact of peer review in reduction of permanent pacemaker implantations. JAMA. 1981;246:754. [PubMed] [Google Scholar]
- 17.Lamas GA, Pashos CL, Normand S-LT, McNeil B. Permanent pacemaker selection and subsequent survival in elderly Medicare pacemaker recipients. Circulation. 1995;91:1063–9. [DOI] [PubMed] [Google Scholar]
- 18.Serban T, Knecht S, du Lavallaz JduF, Nestelberger T, Kaiser C, Leibundgut G, et al. Ventricular pacing burden in patients with left bundle branch block after transcatheter aortic valve replacement therapy. J Cardiovasc Electrophysiol. 2023;34:1464–8. [DOI] [PubMed] [Google Scholar]
- 19.Malyshev Y, Yang F. Editorial comment to: perioperative complications after pacemaker implantation: higher complication rates with subclavian vein puncture than with cephalic vein cut-down (Hasan et al.). J Interv Card Electrophysiol. 2022;66:811–3. [DOI] [PubMed] [Google Scholar]
- 20.White WB, Berberian JG. Pacemaker malfunction-review of permanent pacemakers and malfunctions encountered in the emergency department. Emerg Med Clin North Am. 2022;40:679–91. [DOI] [PubMed] [Google Scholar]
- 21.Kiviniemi MS, Pirnes MA, Eränen HJK, Kettunen RVJ, Hartikainen JEK. Complications related to permanent pacemaker therapy. Pacing Clin Electrophysiol. 1999;22:711–20. [DOI] [PubMed] [Google Scholar]
- 22.Badertscher P, Stortecky S, Serban T, Knecht S, Heg D, Tueller D, Jege R, Reuthebuch O, Muller O, Toggweiler S, et al. Long-Term outcomes of patients requiring pacemaker implantation after transcatheter aortic valve replacement: the swissTAVI registry. JACC Cardiovasc. Interv. 2025. 10.1016/j.jcin.2025.03.028 [DOI] [PubMed]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
No datasets were generated or analysed during the current study.
