Analysis and mitigation of equipment-induced shortcuts in AI models for laparoscopic cholecystectomy

Sergey Protserov 1,2,3, Anastasiia Repalo 1,2,3, Pouria Mashouri 3, Jaryd Hunter 3, Caterina Masino 3, Amin Madani 2,3, Michael Brudno 1,2,3,*
Editor: Adam Hulman4
PMCID: PMC13649130  PMID: 42848867

Abstract

Machine learning models have seen a lot of success in medical image segmentation domain. However, one of the challenges that they face are confounders or shortcuts: spurious correlations or biases in the training data that affect the resulting models. One example of such confounders for surgical machine learning is the setup of surgical equipment, including tools and lighting. Using the task of identification of safe and dangerous zones of dissection in laparoscopic cholecystectomy images and videos as a use-case, we inspect two equipment-induced biases: the location of surgical tools in the field of view and the direction of lighting, both of which are tightly related to the region of interest. We propose methods for evaluating the severity of these biases based on measurements of model consistency under real or simulated exposure to these shortcuts, and augmentation-based methods for mitigating them. We show that our tool bias mitigations based on pasting tool images in random locations improve the models’ prediction consistency under tool movements by 9 percentage points in the most inconsistent cases, and by 4 percentage points on average. Our lighting bias mitigations based on simulated lighting adjustments help reduce fraction of pixels originally predicted as belonging to the dangerous zone that may flip to safe under light changes from 5% to 1.5%, without compromising segmentation quality.

Author summary

Artificial intelligence is increasingly used to support surgeons, for example by highlighting which tissue is safe to cut and which is dangerous during gallbladder removal (laparoscopic cholecystectomy), one of the most common abdominal operations. These systems can, however, learn the wrong lesson. We found that AI models for this task come to rely on where the surgeon places the instruments and where the camera light is pointed, rather than on the anatomy itself. Experienced surgeons tend to position their tools and lighting in predictable places, so the model takes a shortcut. The danger is that a less experienced surgeon, who handles equipment differently, could receive misleading guidance. This flaw is hard to detect because the pattern runs through all of the data, so ordinary testing does not reveal it. We developed a way to measure how strongly a model leans on these shortcuts, and a simple training method that breaks them by inserting instruments and extra lighting at random positions. Our approach makes predictions substantially more consistent without sacrificing accuracy, a step toward surgical AI that offers trustworthy guidance to surgeons at every level of experience.

Introduction

Surgical complications represent a substantial burden on global healthcare systems, contributing significantly to patient morbidity, mortality, and economic costs. Research indicates [1,2] that a significant portion of surgical adverse events is caused by errors in perception and decision-making among surgeons.

The integration of artificial intelligence and machine learning technologies into surgical practice offers a promising approach to addressing these challenges by providing real-time decision support to surgical teams. Advanced deep learning algorithms have demonstrated [3] remarkable capabilities in surgical computer vision tasks, achieving performance comparable to that of expert surgeons for the tasks of anatomical structure identification.

In recent years, deep learning machine models based on convolutional [4] and transformer [5] neural networks have seen much success in the field of medical image segmentation, as evidenced by multiple systematic reviews [6–13]. However, clinical utility of such models is not necessarily directly reflected by segmentation evaluation metrics, such as Dice score, precision and recall. Deployment of these models to clinical environments and their real-world usefulness are hindered by confounders present in the input images [14], allowing the model to demonstrate high performance on held-out test data that does not generalize to other settings. Some examples of such confounders are information that allows the model to distinguish between different hospital systems or departments [15] which have different prevalence of outcome of interest, or location of the object in the field of view being correlated with the segmentation label [16].

In this paper we consider the problem of identifying safe and dangerous zones of dissection during laparoscopic cholecystectomy (LC). While prior work [17,18] has shown that computer vision techniques can have broad applicability to this problem, we have identified two medical equipment-related confounders that are present in training and testing datasets, and affect models developed using this data. Specifically, medical tool location in the field of view and the direction of lighting are both highly correlated with safe and dangerous zone locations, due to how this surgery is performed. The tool tips of dissection instruments (scalpels, cauterizers) are most often found in the safe zone, as this is exactly where the surgeons perform dissections. Similarly, lighting is typically directed to the same zone of interest. Direction of lighting may be further correlated with the tool location, potentially complicating the relationship between tool, lighting and zones of interest.

In this work we propose methods for evaluating the extent to which a given model is affected by these biases. For tool bias, we use both manually and automatically obtained tool segmentations to find pairs of frames that are similar except for tool locations, and assess model prediction consistencies between frames in such pairs. For lighting bias, we assess how model predictions change when different simulated lighting adjustments are applied to the input frames. We therefore show that the models trained on biased datasets are indeed confounded by tool and lighting locations. We further propose augmentation-based strategies for mitigation of these issues, based on pasting in images of surgical instruments in random positions and random local lighting adjustments to break the correlations with safe/dangerous zone location. We show that the best tool bias mitigation result is achieved when the tool pasting augmentation is applied twice per input image during training, and this helps improve the models’ consistency under tool movements by 9 percentage points in the most inconsistent cases, and by 4 percentage points on average, and that tool texture, and not only shape, plays a significant role in these augmentations. We also found that the worst case for lighting bias is when the lighting is directed to the regions inside the predicted safe zone, which is, importantly, the most surgically-relevant scenario, and in such cases our mitigations help reduce the fraction of pixels originally predicted as belonging to the dangerous zone that may be predicted as safe zone under different lighting conditions from 5% to 1.5%. Altogether, we demonstrate that our mitigation strategies indeed help train unbiased models, without compromising segmentation quality, and therefore improve the models’ clinical usefulness and reliability.

Background work

Studies that consider the computer vision tasks related to laparoscopic surgery include EndoNet [19], where the authors develop a model for surgery phase recognition and tool detection in laparoscopic videos, DeepCVS [20], where the authors develop a model for highlighting hepatocystic anatomy and assessing whether the critical view of safety (CVS) has been established during laparoscopic cholecystectomy, and the study [17], where the authors develop models for highlighting hepatocystic anatomy and safe and dangerous zones of dissection during laparoscopic cholecystectomy. More recently Surgesture [21] focused on identifying the surgeon movements during laparoscopic cholecystectomy that can be used to quantify and summarize operative patterns of surgeons with different levels of expertise, while [18] further improved upon results from [17] and proceeded to deploy an optimized version of the model for safe/dangerous zone highlighting. Our work builds upon these publications, however focuses specifically on the biases introduced by medical equipment setup in the field of view. Finally, Zheng et al [22] describe a generative model-based system for improving the quality of laparoscopic videos by reducing image blur and removing smoke and camera fog. They demonstrate that the use of this system helps reduce the operation pause time and surgeon anxiety.

Another broad field of research relevant to this study is shortcut learning [14]. Confounders make models learn spurious correlations (shortcuts) in training data, instead of meaningful features. They are particularly insidious as they are likely to be also present in the test set built via a random split of the training data, leading to overconfidence in the performance of the model. One noteworthy example of such shortcuts is described in [15], where the authors found that convolutional neural networks trained for pneumonia screening from chest X-rays fail to generalize to external sites, while being able to predict which hospital system and even which hospital department a given image comes from. Analysis of activation maps showed that when predicting the source of a given image, the model “pays attention” to image corners, and laterality tokens specifically. The main finding of this paper is that when different hospital systems have different levels of pneumonia prevalence, the models can indirectly leverage this information to produce confounded predictions. The work [16] further studies shortcut learning in the context of medical image segmentation on two different datasets, demonstrating that presence of text and calipers in the fetal ultrasound images provides shortcuts for organ segmentation, and that centered location of skin lesions in the skin lesion segmentation dataset provides shortcuts that cause the models to under-perform if the lesion is not located at the center of the image at test time. That study shows that training on a cleaned-up version of the first dataset with text and calipers removed by inpainting, and applying random cropping augmentations to the second dataset, can help mitigate the respective biases. Our own augmentation-based bias evaluation and mitigation techniques are similar to these ideas proposed in [16]. The study [23] focuses on the shortcut in classifier models for skin cancer prediction which learn that in the ISIC dataset color calibration charts occur only in benign images, but not in malignant ones. The authors demonstrate the existence of this bias in trained models by artificially inserting these charts into malignant images, and inpainting them away in benign images. They further propose a de-biasing strategy based on inpainting the charts with benign skin pixels in biased images. We are not aware of any studies that focus specifically on shortcuts or confounders in surgical videos.

To reduce the impact of shortcuts, general-purpose shortcut learning mitigation strategies are available, such as Deep Feature Reweighting (DFR [24]), which amounts to re-training a model’s last layer on unbiased data, and MARG-CTRL [25] family of methods, which offers shortcut learning mitigation through various modifications of cross-entropy loss used during training.

Methods

Ethics statement

This research uses de-identified patient data, and has been approved by the University Health Network (UHN) Research Ethics Board, REB#20-5349.

Data

In this research, we use the following datasets:

  • The dataset previously described in [18] as Dataset 1 that consists of 2627 images from laparoscopic camera extracted from 289 LC videos across 136 different institutions from 37 countries and all continents, with pixel-level annotations of safe and dangerous zones of dissection available for every image. Safe zones correspond to the areas where a surgeon should perform dissections, while dangerous zones are locations where dissection is likely to result in an injury to the patient. We use this dataset and the problem of safe/dangerous zone segmentation for model bias analyses. The dataset was split into training, validation and testing subsets on a per-video basis, with 1843 images from 201 videos, 390 images from 43 videos and 394 images from 45 videos assigned to the corresponding sets. Out of the 2627 images, 2473 have surgical tools in them and 154 do not. An example of an annotated image from this dataset is shown in Fig 1.

  • Laparoscopic cholecystectomy images from CholecT50 [26], Cholec80 [19], CholecSeg8k [27] and Endoscapes [28] datasets, used with surgical tool segmentation masks from CholecInstanceSeg [29] dataset to train a tool segmentation model. These image datasets overlap with each other and with Dataset 1 described in the first item, so we carefully analyzed the overlaps and selected only a subset of images to ensure no data leakage takes place. The resulting split is 20546 images from 33 videos for training, 6730 images from 11 videos for validation and 3275 images from 11 videos for testing.

  • Two laparoscopic cholecystectomy videos from CholecTrack20 dataset [30] which are not present in any of the above mentioned datasets, used for scaling our tool bias mitigation evaluations to videos with model-provided (as opposed to manual) tool segmentations.

Fig 1. An example annotated image from the LC dataset.

Fig 1

Red highlight shows dangerous zone, green – safe zone, blue – background.

For the purposes of model training and evaluation, all images and masks were downscaled to the height of 128 pixels, and cropped or padded to the width of 288 pixels. Our previous experiments with this data showed that this aspect ratio provides an excellent coverage of the true variety of frame dimensionalities, and that larger resolutions do not provide any improvement.

A dataset overview is given in S1 Table.

Tool bias

Problem statement.

When conducting LC, the surgeons use a variety of surgical tools and instruments to perform a number of tasks, including dissecting, spreading, cutting or burning through tissues. Examples include scalpels, graspers and cauterization tools. If we consider the problem of identifying and highlighting safe and dangerous zones of dissection, it is clear that there is likely to be strong correlation between the positions of tools and the safe zone locations in any dataset for this problem (experienced surgeons are likely to only use tools in safe zones). Because of that, we hypothesize that models trained on such data will be biased by presence of the tools in the field of view, and may provide erroneous predictions depending on the actual location of the surgical tool. This would have the potential of being harmful if the tool is used by a less experienced surgeon, as the safe zone prediction will potentially “follow” the surgical tools.

General principles of evaluation.

Intuitively, a perfectly unbiased model would output the exact same predictions for two otherwise similar input frames that only differ in the positions of surgical tools. Our proposed tool bias evaluation methodology builds upon this idea, with the goal being to validate whether model’s predictions change due to the movement of the tool; the more they change, the more a model is affected by the presence of surgical instruments. Note that we can’t use safe/dangerous zone ground truth for tool bias assessment because that would require annotated frames that are temporally close enough to satisfy the “background is mostly static, only tools move” constraint. For each of the 289 surgical videos we have at most 10 annotated images that are spread uniformly along the video. Therefore, we use consistency of model predictions between similar frames as a proxy. The available ground truth is used to demonstrate that segmentation quality hasn’t dropped as a result of introducing the bias-mitigating augmentations in Section Segmentation performance. We implemented our tool bias evaluation methodology in two different variants, with manual or automated tool location tracking.

Manual evaluation.

We manually identified 23 short video fragments in the testing subset of videos, such that most of the movement in these fragments is attributed to surgical tools, and the background is mostly static. We then used Track Anything [31] program to interactively create frame-by-frame pixel-level annotations of surgical tools in these videos, while manually verifying every annotation. Then, for every such short video, we considered all frames with a step of 100 ms, and all possible pairs of these frames. We used Hausdorff distance between tool locations in the two frames, and mean squared distance between all non-tool pixels to identify frame pairs where the tools are relatively far apart, while the background is largely unchanged. For every video, we selected 50 frame pairs that best satisfied these criteria.

To evaluate a model for tool bias, we obtain the model’s predictions on all selected frames, and consider the predictions’ consistency between frames within every selected pair by measuring class average (average over the three segmentation classes: safe, dangerous and background) of Dice score between predictions obtained for both frames. We chose to use Dice score for this purpose because it is symmetric with respect to which image is considered as ground truth vs which is a predicted mask; this is important since the two frames within a pair are interchangeable.

Automated evaluation.

To demonstrate that manual tool tracking is not strictly necessary and our tool bias evaluation can be run at scale, we also performed the following steps to obtain more candidate frame pairs:

  1. Trained a model for semantic segmentation of surgical tools on the CholecInstanceSeg [29] dataset

  2. Used this model to obtain tool segmentations for the two videos from CholecTrack20 dataset [30]

  3. Using a sliding window of 5 seconds over the relevant parts of these videos, considered pairs of frames within every window

  4. Computed Hausdorff distances between tools, MSEs between non-tool pixels, and safe/dangerous zone segmentation consistencies of the baseline and augmented models for the frame pairs

  5. Considered the frame pairs from the two videos together, binned them by MSE and plotted consistency improvement of the augmented model versus baseline depending on Hausdorff distances between tools in the frame pairs

Mitigations.

To mitigate the tool bias, we used 215 images of surgical tools extracted from the training subset of videos, including from frames that were never annotated for safe/dangerous zones and therefore never used in model training, and defined a tool pasting augmentation, which pastes tools in random positions in the image during training, properly adjusting their size to the size of the target image, and with random rotations. We hope that pasting surgical tools in random places in the input image will break the correlation between tool position and safe zone location, leading to models that are more robust in the presence of surgical instruments. The tools that were used for augmentation include scalpels, graspers and cauterizers, and cover the same tool groups that are present in the validation and testing data subsets. These extracted tool images reflect the diversity of the collected surgical video samples, and by only using the training subset of videos for tool extraction we guarantee that there is no data leakage into the testing subset and procedures. Some examples of raw tool images as extracted from the frames are given in S1 Fig, and examples of tool-augmented images are presented in Fig 2B-C.

Fig 2. Examples of images augmented with our tool pasting augmentation.

Fig 2

A: Original image, without tool augmentation. B: Augmented image 1. C: Augmented image 2. D: Augmented image 3. Here pasted tool is filled with black color to validate whether the texture of the tool is significant.

To simulate presence of multiple tools in the field of view and make our augmentation stronger, we also tried applying the tool pasting augmentation several times to the same image, with 1–3 tools being pasted into every image, depending on a model training hyperparameter.

It is important to note that tool pasting augmentation also has an implicit effect of covering large sections of the original input, which may serve as a strong regularization technique in itself. To study the effect obscuring parts of the image may have on the model, we also consider the augmentation mode where the pasted tool is filled completely with black color (Fig 2D). On average, applying tool pasting augmentation once obstructs 6% of the input image, and applying it twice obstructs 11.5% of the image.

Lighting bias

Problem statement.

During LC, the light mounted on the laparoscopic camera is typically directed to the region of interest, where the dissection is being performed. Therefore, there is likely to be a correlation between direction of lighting and safe zone locations. This bias is also likely to be learned by the model, and may impact the performance of a system in a real-world deployment, especially when used by less experienced surgeons.

Evaluation.

To evaluate to what extent a given model suffers from lighting bias with a given input image, we first obtain the model’s prediction on this image, and then simulate additional lighting in different parts of the image. To study the effect directing lighting to different locations might have on predictions, we simulate lighting centered at different points in the predicted safe zone only, in the predicted dangerous zone only, or anywhere in the image. For every input image, for every lighting simulation mode, we created 50 transformed images. We then assess by how much predictions on the images with simulated lighting differ from the prediction on the original image. The intuition is that a model that is robust to lighting changes should have high consistency. We conduct this experiment on all images in the test subset, and aggregate the results across the images.

Mitigations.

Similarly to the idea of our tool pasting augmentation described in Section Mitigations, we implement a lighting augmentation that locally increases brightness of a random region within the image. The input image is converted from RGB to LAB color space, and a Gaussian blob is added to the L-channel with a center at a random position. The image is then converted back to RGB. For the purposes of evaluation, the intensity of the brightest point (center) of the Gaussian lighting blob is selected randomly between 20 and 50 L-channel points (which range from 0 to 100), for the purposes of augmentation it is fixed at 50 L-channel points. Some examples of images augmented in this manner are presented in Fig 3.

Fig 3. Examples of images augmented with our lighting augmentation.

Fig 3

A: Original image, without lighting augmentation. B: Augmented image 1. C: Augmented image 2, D: Augmented image 3.

Results

Baseline setup

We used SegFormer [32] architecture, and followed the standard machine learning practice of training multiple models with different hyperparameter sets to identify the best model with respect to value of the utilized loss function, cross-entropy, on the validation set. The best model selected in this manner is then used for evaluation on the test set. In our earlier work [18] we showed that SegFormer performs on par with U-Net [33], another well-established semantic segmentation architecture. We resize every image to a height of 128 pixels while preserving the aspect ratio. Our previous work with this dataset showed that this resolution is sufficient. The brightest 100x100 square within the image is selected, and the entire image is standardized so that this square has zero per-channel mean and unit per-channel standard deviation. This strategy is used instead of “regular” standardization, because some inputs have black borders (see Fig 4A) which would distort computations of mean and standard deviation if they were performed over the entire image.

Fig 4. Prediction inconsistencies on two pairs of frames, where top row (A, B) is one pair, bottom row (C, D) is another pair, and frames within each pair are similar except for tool positions.

Fig 4

Red highlights predicted dangerous zone, green – predicted safe zone, blue – predicted background. In both frames the presence of the surgical instrument has resulted in a larger predicted “safe” zone. Ground truth segmentations are not available for these frames.

Baseline tool bias

For our best model trained without tool pasting or lighting augmentations, the per-video consistency scores (described in Section General principles of evaluation), averaged over all selected frame pairs within a video, range between 0.67 and 0.97, with a mean of 0.87 and standard deviation of 0.075, which shows that the model is sensitive to surgical tool position within the field of view. Examples of the prediction inconsistency on two pairs of frames, where frames within a pair are similar except for tool position, are presented in Fig 4.

Tool bias mitigations

Manual tool tracking.

For each of the 23 short video segments and with manual tool tracking (described in the first part of Section Manual evaluation), for every selected pair of frames, we compared consistency of models trained with one and two iterations of tool pasting augmentation against the baseline model by subtracting the per-frame-pair consistency scores and averaging over the frame pairs in every video. Our findings aggregated over videos are presented in Fig 5. They show that for 18 out of 23 videos the model trained with one iteration of tool augmentations is more consistent than the baseline model, and that for 19 out of 23 videos the model trained with two iterations of tool augmentations is more consistent than the baseline model. Also, for 17 out of 23 videos two-iteration model is more consistent than one-iteration model.

Fig 5. Per-video difference in consistency score of the models trained with one (blue) or two (red) iterations of tool pasting augmentation versus the baseline model, for every short video fragment.

Fig 5

Error bars show standard deviation over 50 frame pairs.

To validate our claims statistically, we conducted three one-sided t-tests with paired samples, with the null hypotheses being “average per-video consistency scores for the model without any mitigations are not less than scores for the model with one iteration of tool pasting augmentation,” “average per-video consistency scores for the model without any mitigations are not less than scores for the model with two iterations of tool pasting augmentation,” “average per-video consistency scores for the model with one iteration of tool pasting augmentation are not less than scores for the model with two iterations of tool pasting augmentation,” with n = 23 for every test. The resulting p-values are, respectively, 0.016, 4.65·10−5 and 0.014, indicating significance and rejection of the null hypothesis in all three cases.

Our findings (summarized over all 23 videos) are presented in Table 1.

Table 1. A summary of consistency scores over all videos, for different tool bias mitigation strategies.
Mitigation strategy Min Max Mean ± std
no augmentations 0.668 0.970 0.873 ± 0.075
paste 1 black shape 0.674 0.966 0.876 ± 0.073
paste 1 real tool image 0.698 0.971 0.893 ± 0.062
paste 2 black shapes 0.652 0.973 0.879 ± 0.084
paste 2 real tool images 0.765 0.965 0.908 ± 0.052
paste 3 real tool images 0.780 0.977 0.897 ± 0.048
DFR 0.667 0.945 0.872 ± 0.073
MARG-CTRL 0.714 0.961 0.897 ± 0.053

Applying tool pasting augmentation once or twice improves the model’s robustness, while merely covering parts of the image with tool-shaped black objects does not result in any improvement. No additional benefit is achieved from pasting three tools.

For our best model trained with a tool pasting augmentation applied once for every input image during training, the per-video consistency scores range between 0.7 (was 0.67 for the baseline model) and 0.97 (was 0.97), with a mean of 0.89 (was 0.87) and standard deviation of 0.062 (was 0.075). For our best model trained with a tool pasting augmentation applied twice for every input image, the per-video consistency scores further improved to range between 0.76 and 0.96, with a mean of 0.91 and standard deviation of 0.052. This demonstrates that applying tool pasting augmentation helps improve prediction consistency scores, and that applying the augmentation twice for every image amplifies the effect.

To study the effect increasing the amount of iterations of tool pasting augmentation has on tool bias, and to distinguish between the de-biasing effect from tool pasting and the regularization effect from obstructing parts of the image, we also conducted experiments with three iterations of tool pasting, as well as one or two iterations of pasting tools filled with black color. They show that making more than two iterations of tool pasting augmentation does not provide any further benefit, and that tool texture actually plays a significant role, as merely obstructing parts of the input image with tool-shaped black objects does not help reduce tool bias at all.

We also implemented two pre-existing shortcut learning mitigation methods: DFR [24] and MARG-CTRL [25] (marg-log and SD variants), with proper hyperparameter optimization. DFR did not provide any improvement in consistency, while MARG-CTRL still lagged behind the “two tools” version of our augmentation (Table 1). Another advantage of our approach is that MARG-CTRL’s derivation relies on the model being trained with cross entropy loss and is not necessarily compatible with, e.g., the Dice loss that is frequently used in segmentation settings, and also with object detection problem formulation. Our augmentation is data-driven and loss- and task-agnostic.

To statistically compare our method against MARG-CTRL, we took our strongest augmentation (“two tools” version), and fit a linear mixed-effects model to consistency scores calculated between pairs of video frames. For these purposes, we used lme4 library [34]. The mixed effect model included a fixed effect for the method of correction, and random effects for both the video and frame pair. Our method demonstrated significantly higher consistency scores than MARG-CTRL (p-value = 0.0148).

In Fig 6 we show the predictions of the model trained with two iterations of tool pasting augmentations on the same pairs of frames as in Fig 4. It can be seen that this model is much more consistent than the baseline model.

Fig 6. Predictions of the model trained with two iterations of tool augmentation on the same pairs of frames as were shown in Fig 4.

Fig 6

Red highlights predicted dangerous zone, green – predicted safe zone, blue – predicted background. This model shows much better consistency than the baseline model (Fig 4). Ground truth segmentations are not available for these frames.

Validation at scale

For the automated tool tracking on two videos from CholecTrack20 dataset [30] using the model trained on CholecInstanceSeg [29], Fig 7 shows by how many percentage points our best augmented model is more consistent than the baseline, as the tool movement between frames in a pair grows. This plot shows that the improvement in consistency is always positive and that it grows as the Hausdorff distance between tool positions grows. This is in agreement with our theory that larger discrepancies in tool locations should make it more challenging for the model to stay consistent, and that our mitigation strategies help ensure consistency.

Fig 7. Safe/dangerous zone segmentation consistency improvement of tool-augmented model versus baseline, binned over non-tool pixel MSE and plotted against tool position Hausdorff distance.

Fig 7

Another takeaway from these experiments is that the surgical tool semantic segmentation model trained on CholecInstanceSeg dataset can be further used to extract more tool images and remove the need for manual tool annotation prior to using them for augmentation.

One could argue that numerical improvements of consistency may be misleading, because the model may be very consistent, but consistently wrong. In Section Segmentation performance we show that this is not the case for our augmented models, as they perform roughly on the same level as baseline models in terms of safe/dangerous zone segmentation metrics.

Baseline lighting bias

As described in Section Evaluation, to evaluate lighting bias we assess how much the model’s predictions change when we consider predictions on the original input image to be “ground truth”, and compare predictions on images with local lighting adjustments against them. We found that the most drastic changes occur when the center of the simulated lighting blob is in the predicted safe zone, which is, importantly, the most surgically-relevant scenario, and further consider this case specifically. Fig 8A shows row-normalized confusion matrix (computed for every original image with all its transformations, then averaged over all original images), where every entry in position ci,cj shows what proportion of pixels that originally belonged to class ci belong to class cj in the transformed image. These results show that on average, 5% of the pixels originally predicted as a dangerous zone are classified as safe due to lighting adjustment. This is a dangerous mistake to make. Further, lighting adjustment causes another 5% of pixels originally predicted as belonging to dangerous zone to be predicted as background. Fig 8B shows fully-normalized confusion matrix (computed for every original image with all its transformations, then averaged over all original images), where every entry in position ci,cj shows what proportion of pixels originally belonged to class ci and belong to class cj in the transformed image. Fully-normalized confusion matrices are used to highlight zone size changes. Baseline model that does not use augmentation shows higher changes in zone sizes: dangerous zone shrinks by 7%, while safe zone and background grow by 2% and 1.5% respectively.

Fig 8. Confusion matrices for lighting bias.

Fig 8

A: Row-normalized, without tool pasting or lighting augmentations. B: Fully-normalized, without tool pasting or lighting augmentations. C: Row-normalized, with lighting augmentations. D: Fully-normalized, with lighting augmentations.

Lighting bias mitigations

Row-normalized and fully-normalized confusion matrices for the best model trained with random lighting augmentations are presented in Fig 8C and Fig 8D. They show that only 1.5% (was 5% without augmentations) of dangerous zone pixels can now be made to be predicted as safe zone, and 3.3% (was 5%) – as background. A model that uses lighting augmentation also results in much more consistent sizes of predicted zones (dangerous zone shrinks by 2%, safe zone shrinks by around 0.1% and background grows by less than 0.7%). Random lighting augmentation makes the model more robust to lighting changes, and helps prevent dangerous pixel misclassifications.

Segmentation performance

While we have shown that models with lighting and tool augmentations are more consistent, it is also important to validate that their performance on the core task has not degraded as a result. Fig 9 shows row-normalized confusion matrices for segmentation quality for the baseline model and model with both two iterations of tool pasting augmentation and lighting augmentation. These confusion matrices show that the two models perform roughly on the same level in terms of segmentation quality, with the model with the augmentations performing slightly better, demonstrating that the proposed tool pasting and lighting augmentations do not affect segmentation quality on the dataset affected by both tool and location biases. One might wonder why the segmentation performance is almost unchanged given that the models trained with augmentations are supposed to generalize better by being more robust to spurious correlations. The reason is that such models are only supposed to generalize better to datasets not affected by these correlations, which, in this case, means real-life surgeries performed by less experienced surgeons, who may have difficulties with equipment positioning. Since the entirety of our dataset, including training, validation and testing splits, has such shortcuts, we expected the segmentation performance to remain roughly on the same level.

Fig 9. Row-normalized confusion matrices for segmentation quality.

Fig 9

A: Baseline model. B: Model with both two iterations of tool pasting and lighting augmentations.

Discussion

We have shown that surgical tool position and lighting direction act as confounders in training data for laparoscopic cholecystectomy computer vision models. Confounders of this kind elude standard machine learning evaluation: because the training, validation, and test splits all share the same shortcuts, a held-out test set, even one from a different institution, does not reveal the bias but rewards it. This is also why strong segmentation metrics do not necessarily reflect clinical utility. Dice, precision, and recall measure agreement with reference annotations on a same-distribution test set, so when a confounder pervades every split, high scores can coexist with behavior that is unreliable in the operating room.

Our consistency-based evaluation exposes this gap directly: a model can score well on static images yet change its safe and dangerous zone predictions when only an instrument’s position or the direction of lighting changes. Assessing clinical utility therefore requires measuring the stability of predictions under clinically realistic perturbations, not accuracy on a fixed test set alone.

These failure modes are clinically consequential. A predicted safe zone that expands to follow the instrument, or the baseline model’s reassignment of 5% of the pixels originally predicted as dangerous to the safe class when lighting is directed into the predicted safe zone (the most surgically relevant case, since it is where dissection occurs) are precisely the errors that could lead an operator to cut in a region that is in fact dangerous but that the system has labeled safe: the injury that safe and dangerous zone guidance exists to prevent. This risk is, moreover, unlikely to be evenly distributed. It would fall most heavily on surgeons in training and on those practicing in resource-limited settings, whose handling of instruments and lighting may depart from the expert patterns the model has implicitly encoded; a system that is least dependable for the operators who stand to benefit most from decision support inverts its own purpose and raises a question of equity alongside safety. We have not yet evaluated our models on data from less experienced operators, so this differential is a reasoned expectation grounded in the mechanism of the shortcut rather than a measured result; demonstrating it directly is an important direction for future work.

Our mitigation strategy addresses these confounders by decoupling anatomical recognition from equipment configuration, removing the model’s dependence on a cue that reflects who is operating rather than the anatomy itself. Because the augmentations are data-driven and agnostic to both the loss function and the model architecture, they can be incorporated into existing surgical AI training pipelines (and the consistency evaluation into existing validation protocols) without architectural change, lowering the barrier to adoption and likely generalizing beyond the SegFormer architecture used here. We expect both the problem and the mitigation to extend to other tasks on these datasets, such as identifying the liver, gallbladder, or hepatocystic triangle, or assessing whether the field of view and retraction are adequate, and to other surgical computer-vision problems. None of this comes at the cost of segmentation quality, which remains similar or slightly improved on our (necessarily biased) data (Section Segmentation performance).

As a limitation, we note that our augmented model failed to improve consistency under tool movements on 6 of 23 tested videos (see Fig 5). We conducted a manual analysis of these videos, and failed to identify a clear cause. One possible explanation is that during the manual evaluation phase the values of Hausdorff distance between tools and MSE between other pixels weren’t taken into account after they were used to select the frame pairs. In fact, these two measurements could be used to weigh the consistency scores of individual frame pairs during aggregation (as we did in the automated evaluation, summarized in Fig 7). We did not take into account these measurements during aggregation for manual evaluation, as that would complicate the analysis.

More broadly, the pervasiveness of these shortcuts in surgical datasets points to two needs: evaluation frameworks for medical computer vision that test consistency across variable conditions rather than accuracy on static images, and more diverse surgical datasets that deliberately capture variability in equipment positioning and other technical factors that would otherwise become hidden confounders. Together, these steps move the field toward surgical AI whose guidance can be trusted across the range of surgeons and operating conditions encountered in practice, a goal distinct from demonstrating strong performance on a single test dataset.

Supporting information

S1 Fig. Examples of tool images extracted from the video frames.

(TIF)

pdig.0001421.s001.tif (537.8KB, tif)
S1 Table. Overview of the datasets used in this study.

(PDF)

pdig.0001421.s002.pdf (41.6KB, pdf)

Acknowledgments

Declaration of generative AI and AI-assisted technologies use in the manuscript preparation process: During the preparation of this work the authors used a GLM 4.6 model as provided by Venice AI service, and a Claude Opus 4.8 model as provided by Anthropic, for editorial assistance. After using these services, the authors reviewed and edited the manuscript and take full responsibility for the content of the published paper.

Data Availability

The various datasets utilized in our paper are available as follows: The dataset previously referred to as “Dataset 1” in (Protserov et al., 2024) is human subject data that cannot be shared directly due to REB restrictions. The dataset is made available upon request through the Global Surgical Artificial Intelligence Collaborative. For access, please email info@surgicalai.org. The CholecT50, Cholec80, Endoscapes and CholecTrack20 datasets are described and available for download at https://camma.unistra.fr/datasets/, also see the information on data overlaps between the various datasets at https://github.com/CAMMA-public/camma_dataset_overlaps. The CholecInstanceSeg dataset is described and available for download at https://github.com/cai4cai/cholec_instance_seg. The CholecSeg8k dataset is described and available for download at https://www.kaggle.com/datasets/newslab/cholecseg8k. We make our code and model weights available at https://github.com/data-team-uhn/equipment_induced_shortcuts_in_lc.

Funding Statement

This study was funded by the University Health Network Foundation and an NSERC Discovery grant to M.B. M.B. is a CIFAR CCAI chair. The funders played no role in study design, data collection, analysis and interpretation of data, or the writing of this manuscript.

References

  • 1.Way LW, Stewart L, Gantert W, Liu K, Lee CM, Whang K, et al. Causes and prevention of laparoscopic bile duct injuries: Analysis of 252 cases from a human factors and cognitive psychology perspective. Ann Surg. 2003;237(4):460–9. doi: 10.1097/01.SLA.0000060680.92690.E9 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Madani A, Vassiliou MC, Watanabe Y, Al-Halabi B, Al-Rowais MS, Deckelbaum DL, et al. What are the principles that guide behaviors in the operating room?: Creating a framework to define and measure performance. Ann Surg. 2017;265(2):255–67. doi: 10.1097/SLA.0000000000001962 [DOI] [PubMed] [Google Scholar]
  • 3.den Boer RB, de Jongh C, Huijbers WTE, Jaspers TJM, Pluim JPW, van Hillegersberg R, et al. Computer-aided anatomy recognition in intrathoracic and -abdominal surgery: A systematic review. Surg Endosc. 2022;36(12):8737–52. doi: 10.1007/s00464-022-09421-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.LeCun Y, Bengio Y, Hinton G. Deep learning. Nature 2015;521:436–44. 10.1038/nature14539 [DOI] [PubMed] [Google Scholar]
  • 5.Vaswani A, Shazeer N, Parmar N, Uszkoreit J, Jones L, Gomez AN, et al. Attention is All you Need. In: Neural Information Processing Systems; 2017. Available from: https://api.semanticscholar.org/CorpusID:13756489
  • 6.Esteva A, Chou K, Yeung S, Naik N, Madani A, Mottaghi A, et al. Deep learning-enabled medical computer vision. NPJ Digit Med. 2021;4(1):5. doi: 10.1038/s41746-020-00376-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 7.Elyan E, Vuttipittayamongkol P, Johnston P, Martin K, McPherson K, Moreno-García CF, et al. Computer vision and machine learning for medical image analysis: Recent advances, challenges, and way forward. Art Int Surg. 2022. doi: 10.20517/ais.2021.15 [DOI] [Google Scholar]
  • 8.Garrow CR, Kowalewski K-F, Li L, Wagner M, Schmidt MW, Engelhardt S, et al. Machine learning for surgical phase recognition: A systematic review. Ann Surg. 2021;273(4):684–93. doi: 10.1097/SLA.0000000000004425 [DOI] [PubMed] [Google Scholar]
  • 9.Nich C, Behr J, Crenn V, Normand N, Mouchère H, d’Assignies G. Applications of artificial intelligence and machine learning for the hip and knee surgeon: Current state and implications for the future. Int Orthop. 2022;46(5):937–44. doi: 10.1007/s00264-022-05346-9 [DOI] [PubMed] [Google Scholar]
  • 10.Chadebecq F, Vasconcelos F, Mazomenos E, Stoyanov D. Computer vision in the surgical operating room. Visc Med. 2020;36(6):456–62. doi: 10.1159/000511934 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Mascagni P, Alapatt D, Sestini L, Altieri MS, Madani A, Watanabe Y, et al. Computer vision in surgery: From potential to clinical value. NPJ Digit Med. 2022;5(1):163. doi: 10.1038/s41746-022-00707-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Pedrett R, Mascagni P, Beldi G, Padoy N, Lavanchy JL. Technical skill assessment in minimally invasive surgery using artificial intelligence: A systematic review. Surg Endosc. 2023;37(10):7412–24. doi: 10.1007/s00464-023-10335-z [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Guo K, Tao H, Zhu Y, Li B, Fang C, Qian Y, et al. Current applications of artificial intelligence-based computer vision in laparoscopic surgery. Laparosc Endosc Robot Surg. 2023;6(3):91–96. doi: 10.1016/j.lers.2023.07.001 [DOI] [Google Scholar]
  • 14.Geirhos R, Jacobsen J-H, Michaelis C, Zemel R, Brendel W, Bethge M, et al. Shortcut learning in deep neural networks. Nat Mach Intell. 2020;2(11):665–73. doi: 10.1038/s42256-020-00257-z [DOI] [Google Scholar]
  • 15.Zech JR, Badgeley MA, Liu M, Costa AB, Titano JJ, Oermann EK. Variable generalization performance of a deep learning model to detect pneumonia in chest radiographs: A cross-sectional study. PLoS Med. 2018;15(11):e1002683. doi: 10.1371/journal.pmed.1002683 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Lin M, Weng N, Mikolaj K, Bashir Z, Svendsen MBS, Tolsgaard MG, et al. Shortcut Learning in Medical Image Segmentation. In: International Conference on Medical Image Computing and Computer-Assisted Intervention. 2024. Available from: https://api.semanticscholar.org/CorpusID:268356676
  • 17.Madani A, Namazi B, Altieri MS, Hashimoto DA, Rivera AM, Pucher PH, et al. Artificial intelligence for intraoperative guidance. Ann Surg. 2022;276(2):363–9. doi: 10.1097/SLA.0000000000004594 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Protserov S, Hunter J, Zhang H, Mashouri P, Masino C, Brudno M, et al. Development, deployment and scaling of operating room-ready artificial intelligence for real-time surgical decision support. NPJ Digit Med. 2024;7(1):231. doi: 10.1038/s41746-024-01225-2 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Twinanda AP, Shehata S, Mutter D, Marescaux J, de Mathelin M, Padoy N. EndoNet: A deep architecture for recognition tasks on laparoscopic videos. IEEE Trans Med Imaging. 2017;36(1):86–97. doi: 10.1109/TMI.2016.2593957 [DOI] [PubMed] [Google Scholar]
  • 20.Mascagni P, Vardazaryan A, Alapatt D, Urade T, Emre T, Fiorillo C, et al. Artificial intelligence for surgical safety. Ann Surg. 2022;275(5):955–61. doi: 10.1097/SLA.0000000000004351 [DOI] [PubMed] [Google Scholar]
  • 21.Chen Z, An J, Wu S, Cheng K, You J, Liu J, et al. Surgesture: A novel instrument based on surgical actions for objective skill assessment. Surg Endosc. 2022;36(8):6113–21. doi: 10.1007/s00464-022-09108-x [DOI] [PubMed] [Google Scholar]
  • 22.Zheng Q, Yang R, Ni X, Yang S, Jiang Z, Wang L, et al. Development and validation of a deep learning-based laparoscopic system for improving video quality. Int J Comput Assist Radiol Surg. 2023;18(2):257–68. doi: 10.1007/s11548-022-02777-y [DOI] [PubMed] [Google Scholar]
  • 23.Nauta M, Walsh R, Dubowski A, Seifert C. Uncovering and correcting shortcut learning in machine learning models for skin cancer diagnosis. Diagnostics (Basel). 2021;12(1):40. doi: 10.3390/diagnostics12010040 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Kirichenko P, Izmailov P, Wilson AG. Last Layer Re-Training is Sufficient for Robustness to Spurious Correlations. arXiv preprint arXiv:2204.02937. 2022. Available from: https://api.semanticscholar.org/CorpusID:247996741
  • 25.Puli A, Zhang LH, Wald Y, Ranganath R. Don’t blame Dataset Shift! Shortcut Learning due to Gradients and Cross Entropy. ArXiv. 2023. arXiv:2308.12553. Available from: https://api.semanticscholar.org/CorpusID:261101253
  • 26.Nwoye CI, Yu T, Gonzalez C, Seeliger B, Mascagni P, Mutter D, et al. Rendezvous: Attention mechanisms for the recognition of surgical action triplets in endoscopic videos. Med Image Anal. 2022;78:102433. doi: 10.1016/j.media.2022.102433 [DOI] [PubMed] [Google Scholar]
  • 27.Hong WY, Kao CL, Kuo YH, Wang JR, Chang WL, Shih CS. CholecSeg8k: A Semantic Segmentation Dataset for Laparoscopic Cholecystectomy Based on Cholec80. 2020. Available from: https://arxiv.org/abs/2012.12453
  • 28.Murali A, Alapatt D, Mascagni P, Vardazaryan A, Garcia A, Okamoto N, et al. The Endoscapes dataset for surgical scene segmentation, object detection, and critical view of safety assessment: Official splits and benchmark. arXiv preprint arXiv:2312.12429. 2023. [Google Scholar]
  • 29.Alabi O, Toe KKZ, Zhou Z, Budd C, Raison N, Shi M, et al. CholecInstanceSeg: A tool instance segmentation dataset for laparoscopic surgery. Sci Data. 2025;12(1):825. doi: 10.1038/s41597-025-05163-w [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.Nwoye CI, Elgohary K, Srinivas A, Zaid F, Lavanchy JL, Padoy N. CholecTrack20: A Multi-Perspective Tracking Dataset for Surgical Tools. In: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). 2025.
  • 31.Yang J, Gao M, Li Z, Gao S, Wang F, Zheng F. Track Anything: Segment Anything meets videos. arXiv preprint arXiv:2304.11968. 2023. 10.48550/arXiv.2304.11968 [DOI]
  • 32.Xie E, Wang W, Yu Z, Anandkumar A, Álvarez JM, Luo P. SegFormer: Simple and Efficient Design for Semantic Segmentation with Transformers. In: Neural Information Processing Systems. 2021. Available from: https://api.semanticscholar.org/CorpusID:235254713
  • 33.Ronneberger O, Fischer P, Brox T. U-Net: Convolutional Networks for Biomedical Image Segmentation. ArXiv. 2015. arXiv:1505.04597. Available from: https://api.semanticscholar.org/CorpusID:3719281
  • 34.Bates D, Mächler M, Bolker B, Walker S. Fitting linear mixed-effects models using lme4. J Stat Softw. 2015;67(1):1–48. doi: 10.18637/jss.v067.i01 [DOI] [Google Scholar]
PLOS Digit Health. doi: 10.1371/journal.pdig.0001421.r001

Decision Letter 0

Feng Liu, Adam Hulman

7 Jun 2026

Response to Reviewers Revised Manuscript with Track Changes Manuscript Journal Requirements:

1. Please amend your detailed Financial Disclosure statement. This is published with the article. It must therefore be completed in full sentences and contain the exact wording you wish to be published.

a. State what role the funders took in the study. If the funders had no role in your study, please state: “The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.”

b. If any authors received a salary from any of your funders, please state which authors and which funders.

2. We ask that a manuscript source file is provided at Revision. Please upload your manuscript file as a .doc, .docx, .rtf or .tex.

3. Please provide separate figure files in .tif or .eps format.

For more information about figure files please see our guidelines:  LINK

https://journals.plos.org/digitalhealth/s/figures

https://journals.plos.org/digitalhealth/s/figures#loc-file-requirements

4. Please provide an Author Summary. This should appear in your manuscript between the Abstract (if applicable) and the Introduction, and should be 150–200 words long. The aim should be to make your findings accessible to a wide audience that includes both scientists and non-scientists. Sample summaries can be found on our website under Submission Guidelines: [LINK]

https://journals.plos.org/digitalhealth/s/submission-guidelines#loc-parts-of-a-submission

5. Your manuscript is missing the following sections: Discussion. Please ensure these are present, and in the correct order, and that any references to subheadings in your main text are correct. An outline of the required sections can be consulted in our submission guidelines here: [LINK]

https://journals.plos.org/digitalhealth/s/submission-guidelines#loc-parts-of-a-submission

6. In the online submission form, you indicated that "All data used in this research is either already available and cited appropriately, or available upon request.".

All PLOS journals now require all data underlying the findings described in their manuscript to be freely available to other researchers, either

1. In a public repository,

2. Within the manuscript itself, or

3. Uploaded as supplementary information.

This policy applies to all data except where public deposition would breach compliance with the protocol approved by your research ethics board. If your data cannot be made publicly available for ethical or legal reasons (e.g., public availability would compromise patient privacy), please explain your reasons by return email and your exemption request will be escalated to the editor for approval. Your exemption request will be handled independently and will not hold up the peer review process, but will need to be resolved should your manuscript be accepted for publication. One of the Editorial team will then be in touch if there are any issues.

7. Some material included in your submission may be copyrighted. According to PLOS’s copyright policy, authors who use figures or other material (e.g., graphics, clipart, maps) from another author or copyright holder must demonstrate or obtain permission to publish this material under the Creative Commons Attribution 4.0 International (CC BY 4.0) License used by PLOS journals. Please closely review the details of PLOS’s copyright requirements here: PLOS Licenses and Copyright. If you need to request permissions from a copyright holder, you may use PLOS's Copyright Content Permission form.

Please respond directly to this email or email the journal office and provide any known details concerning your material's license terms and permissions required for reuse, even if you have not yet obtained copyright permissions or are unsure of your material's copyright compatibility.

Potential Copyright Issues:

Figures 1,2,3,4,6: Please confirm (a) that you are the photographer; or (b) provide written permission from the photographer to publish the photo(s) under our CC-BY 4.0 license.

Additional Editor Comments (if provided): Reviewers' Comments:

Comments to the Author

1. Does this manuscript meet PLOS Digital Health’s publication criteria?>

Reviewer #1: Yes

Reviewer #2: Yes

**********

2. Has the statistical analysis been performed appropriately and rigorously?-->?>

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Have the authors made all data underlying the findings in their manuscript fully available (please refer to the Data Availability Statement at the start of the manuscript PDF file)??>

The PLOS Data policy

Reviewer #1: Yes

Reviewer #2: No

**********

4. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

Reviewer #2: Yes

**********

Reviewer #1: In this study, the authors identify and mitigate two shortcuts in the segmentation of laparoscopic cholecystectomy data with tools and lighting. The authors train a SegFormer model with data augmentation techniques, adding random tools or lighting to the images to mitigate the shortcuts. They show that training with such data augmentation improves the segmentation consistency across frames with different tool locations and lighting.

Strengths:

- The paper is overall clear and easy to follow. The figures and results nicely support the findings.

- The study is complete, with both shortcut identification and mitigation.

- The mitigation techniques based on data augmentation are simple and applicable to other models and other datasets.

- The authors include both performance variability and statistical analysis.

Weaknesses:

- It would be nice to motivate or explain further the lack of ground truth in the tool bias evaluation. Performance is important since, as the authors mention, you may be more consistent but in a wrong way. Why not use frames with ground truth available to have an evaluation of performance as well? It could be because there is not enough in the data, but this is not really explained currently.

- There is no explanation of what the added tools are. Are they tools extracted from other images in the dataset or from online sources? It could also be relevant to discuss whether the choice of tools can impact the mitigation (e.g., if the tools in the mitigation and in the test set are different).

- The authors already cite [16] for their study on shortcut learning in medical segmentation, but I believe it should be mentioned that they also propose mitigating the shortcut through data augmentation/modification, which is related to the method proposed in this submission.

- Two comments on reproducibility:

- I may have missed it, but I don’t see a link to the source code. It would be nice to have it publicly available.

- It would also be nice to include the final model's hyper parameters for the training.

Reviewer #2: Review comments:

Protserov et al. present a well-designed study investigating strategies to mitigate shortcut learning related to tool position and lighting direction. The experimental design is robust, the analyses are comprehensive, and the topic is highly relevant to the development of trustworthy computer vision systems in healthcare. I believe the study is within the scope of PLOS Digital Health and addresses an important methodological challenge.

My main concern relates to the presentation of the work rather than the study itself. While the manuscript structure complies with PLOS Digital Health’s publication requirements, I found it difficult to distinguish between methodological details, results, and interpretation. As a consequence, some important methodological information and discussion points were not always easy to locate. I believe the manuscript would benefit from clearer reporting in several areas outlined below.

The comments are ordered by importance, then by appearance in the article.

1. In the Abstract, the study's main focus and key takeaways could be communicated more clearly. The current abstract emphasizes the background of shortcut learning but provides comparatively limited detail on the study design, principal findings, and conclusions.

2. In Section 3.2 (Data), there should be a comprehensive overview of all datasets used in the study, including Dataset 1, CholecTrack20, and Endoscapes. A summary table that includes the number of videos, the number of frames, the image resolution, and the number of frames containing visible tools would be helpful. I also recommend reporting the characteristics of the augmented subsets alongside those of the original datasets, as augmentation is a key component of the study.

3. In Section 4.4 (Validation at Scale), important methodological details are introduced within the Results section. I recommend providing a sufficiently detailed methodological description in the Methods section. This would make it easier for readers to understand the full picture of the study design and evaluate the reported findings.

4. In Section 4.3 (Tool Mitigation Bias), the results indicate that the augmentation strategy does not improve consistency across all videos. This is an interesting observation that could benefit from further discussion.

5. In the Introduction, the authors briefly mentioned the evaluation of clinical utility as an important challenge. However, this topic receives limited attention in the remainder of the manuscript. I encourage the authors to expand the discussion of the clinical implications of their findings and how the proposed mitigation strategy may contribute to the development of clinically reliable surgical AI systems.

6. Please include additional information to improve reproducibility, including code, trained model weights, preprocessing pipelines, and the availability of other materials.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

Do you want your identity to be public for this peer review?  If you choose “no”, your identity will remain anonymous but your review may still be made public.

For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #2: No

**********

Figure resubmission:

Reproducibility: --> -->-->To enhance the reproducibility of your results, we recommend that authors of applicable studies deposit laboratory protocols in protocols.io, where a protocol can be assigned its own identifier (DOI) such that it can be cited independently in the future. Additionally, PLOS ONE offers an option to publish peer-reviewed clinical study protocols. Read more information on sharing protocols at https://plos.org/protocols?utm_medium=editorial-email&utm_source=authorletters&utm_campaign=protocols-->?>

PLOS Digit Health. doi: 10.1371/journal.pdig.0001421.r003

Decision Letter 1

Feng Liu, Adam Hulman

10 Aug 2026

Analysis and Mitigation of Equipment-induced Shortcuts in AI Models for Laparoscopic Cholecystectomy

PDIG-D-26-00676R1

Dear Dr. Brudno,

We are pleased to inform you that your manuscript 'Analysis and Mitigation of Equipment-induced Shortcuts in AI Models for Laparoscopic Cholecystectomy' has been provisionally accepted for publication in PLOS Digital Health.

Before your manuscript can be formally accepted you will need to complete some formatting changes, which you will receive in a follow-up email from a member of our team.

Please note that your manuscript will not be scheduled for publication until you have made the required changes, so a swift response is appreciated.

IMPORTANT: The editorial review process is now complete. PLOS will only permit corrections to spelling, formatting or significant scientific errors from this point onwards. Requests for major changes, or any which affect the scientific understanding of your work, will cause delays to the publication date of your manuscript.

If your institution or institutions have a press office, please notify them about your upcoming paper to help maximize its impact. If they'll be preparing press materials, please inform our press team as soon as possible -- no later than 48 hours after receiving the formal acceptance. Your manuscript will remain under strict press embargo until 2 pm Eastern Time on the date of publication. For more information, please contact digitalhealth@plos.org.

Thank you again for supporting Open Access publishing; we are looking forward to publishing your work in PLOS Digital Health.

Best regards,

Adam Hulman, Ph.D.

Academic Editor

PLOS Digital Health

***********************************************************

Reviewer Comments (if any, and for reference):

Reviewer's Responses to Questions

Comments to the Author

Reviewer #1: All comments have been addressed

Reviewer #2: All comments have been addressed

**********

publication criteria?>

Reviewer #1: Yes

Reviewer #2: Yes

**********

3. Has the statistical analysis been performed appropriately and rigorously?-->?>

Reviewer #1: Yes

Reviewer #2: Yes

**********

4. Have the authors made all data underlying the findings in their manuscript fully available (please refer to the Data Availability Statement at the start of the manuscript PDF file)??>

The PLOS Data policy

Reviewer #1: Yes

Reviewer #2: Yes

**********

5. Is the manuscript presented in an intelligible fashion and written in standard English??>

Reviewer #1: Yes

Reviewer #2: Yes

**********

Reviewer #1: I thank the authors for their answers and the revised article. All my comments have been addressed.

Reviewer #2: Thank you for your thoughtful revision. I appreciate the effort the authors put into addressing all of my comments. I have reviewed the revised manuscript and am satisfied that my concerns have been adequately addressed. I have no further comments and believe the manuscript is suitable for publication.

**********

what does this mean?). If published, this will include your full peer review and any attached files.

Do you want your identity to be public for this peer review?  If you choose “no”, your identity will remain anonymous but your review may still be made public.

For information about this choice, including consent withdrawal, please see our Privacy Policy

Reviewer #1: No

Reviewer #2: No

**********

Associated Data

    This section collects any data citations, data availability statements, or supplementary materials included in this article.

    Supplementary Materials

    S1 Fig. Examples of tool images extracted from the video frames.

    (TIF)

    pdig.0001421.s001.tif (537.8KB, tif)
    S1 Table. Overview of the datasets used in this study.

    (PDF)

    pdig.0001421.s002.pdf (41.6KB, pdf)
    Attachment

    Submitted filename: responses_to_the_reviewers.pdf

    pdig.0001421.s003.pdf (112.8KB, pdf)

    Data Availability Statement

    The various datasets utilized in our paper are available as follows: The dataset previously referred to as “Dataset 1” in (Protserov et al., 2024) is human subject data that cannot be shared directly due to REB restrictions. The dataset is made available upon request through the Global Surgical Artificial Intelligence Collaborative. For access, please email info@surgicalai.org. The CholecT50, Cholec80, Endoscapes and CholecTrack20 datasets are described and available for download at https://camma.unistra.fr/datasets/, also see the information on data overlaps between the various datasets at https://github.com/CAMMA-public/camma_dataset_overlaps. The CholecInstanceSeg dataset is described and available for download at https://github.com/cai4cai/cholec_instance_seg. The CholecSeg8k dataset is described and available for download at https://www.kaggle.com/datasets/newslab/cholecseg8k. We make our code and model weights available at https://github.com/data-team-uhn/equipment_induced_shortcuts_in_lc.


    Articles from PLOS Digital Health are provided here courtesy of PLOS

    RESOURCES