Abstract
Background: Left Atrial Appendage (LAA) causes a thrombus risk in patients with atrial fibrillation (AF). Accurate identification of LAA morphology reduces thrombotic stroke. Methods: This study proposes a hybrid deep learning framework, Left Atrial Appendage Thrombus Framework (LAATF), which integrates Adaptive CLAHE, optimized Chan–Vese contour extraction, and a multi-headed AgileFormer transformer to classify LAA morphology, detect thrombus, and estimate image-derived thromboembolic risk using the LightGBM-based proposed Thromboembolic Risk index (TRI) score. A dataset of 4320 temporal images from 240 patients with AF was used, comprising four LAA morphologies (chicken-wing, windsock, cactus, and cauliflower). CLAHE enhanced local contrast. The Chan–Vese model delineated appendage contours. AgileFormer extracted image-derived textural and morphological features to classify morphology and thrombus presence. LightGBM-based TRI regression estimated thromboembolic risk in AF patients with LAA. Results: The proposed framework achieved a morphology classification accuracy of 91–94% and thrombus detection AUC of 0.935, with a sensitivity of 93.4% and specificity of 92.6%. The computed TRI correlated strongly with actual outcomes (R2 = 0.98, r = 0.99). Among morphologies, cauliflower and cactus types show the highest thromboembolic risk due to their increased texture entropy and image-based features. Conclusions: The LAATF framework provides an interpretable, image-based technique for LAA morphology assessment and thrombus prediction.
Keywords: left atrial appendage, thrombus, atrial fibrillation, transoesophageal echocardiography, AgileFormer, LightGBM, thromboembolic risk, deep learning
1. Introduction
The Left Atrial Appendage (LAA) is a muscular, ear-shaped pouch that extends from the left atrium (LA) of the heart. The LAA is located in the pericardial space, near the free wall of the left ventricle [1]. It acts as an embryonic remnant of the LA and retains pectinate muscles, which connect to the atrial chamber. The morphology of the LAA is classified into four main types, such as (i) chicken wing, (ii) cactus, (iii) windsock, and (iv) cauliflower, based on shape and the number of lobes present [2]. Under normal sinus rhythm, the LAA performs several physiological functions, such as (i) serving as a reservoir that stores excess blood during the systole of the LA, (ii) assisting in atrial emptying through its contractile function, (iii) secreting Atrial Natriuretic Peptide (ANP) to help regulate blood pressure, and (iv) serving as a pressure buffer to reduce excessive LA pressure [3]. However, the limitation of the LAA is the formation of blood clots in individuals with atrial fibrillation (AF), which leads to strokes in these patients [4]. In patients with AF, the LAA remodels its trabeculated interior and loses contractility, increasing the risk of thrombus formation. The complex morphology of the LAA makes imaging challenging by complicating the visualization of both the LAA and any thrombus present, which necessitates the placement of a device to close the LAA [5]. Figure 1 illustrates the LAA morphology and its characteristics.
Figure 1.

LAA morphology.
LAA morphology is detected through Transoesophageal Echocardiography (TEE), Cardiac Computed Tomography (CT), cardiac magnetic resonance imaging (CMR), 3D TEE, and Intracardiac Echocardiography (ICE). Table 1 shows the LAA detection methods and their advantages and disadvantages.
Table 1.
LAA detection methods.
| Detection Method | Methodology | Detection Technique | Advantages | Disadvantages |
|---|---|---|---|---|
| Transoesophageal Echocardiography (TEE) | Inserting an ultrasound probe into the esophagus to capture high-resolution images of the LAA. | Direct visualization of LAA morphology, thrombus detection. | Gold standard for thrombus detection; high spatial resolution; real-time imaging. | Semi-invasive; requires sedation; may cause esophageal discomfort or complications. |
| Transthoracic Echocardiography (TTE) | Non-invasive chest wall ultrasound using 2D or 3D probes. | Visualizes cardiac chambers and sometimes LAA with limited clarity. | Widely available; safe; useful for initial screening. | Limited resolution for LAA; poor visualization in obese or lung-diseased patients. |
| Cardiac Computed Tomography (CT) | Uses contrast-enhanced CT angiography to reconstruct 3D images of the heart and LAA. | 3D reconstruction to evaluate LAA shape, volume, and presence of thrombus. | precise morphology classification; rapid scan time. | Radiation exposure; contrast nephropathy risk; cannot assess real-time flow. |
| Cardiac Magnetic Resonance Imaging (MRI) | Uses magnetic fields and gadolinium contrast for soft tissue characterization. | Phase-contrast or delayed-enhancement MRI for LAA visualization and thrombus detection. | Superior soft tissue contrast; no radiation | Long scan time; expensive |
| 3D Echocardiography (3D-TEE/TTE) | Advanced echocardiographic reconstruction for full 3D morphology. | Volumetric rendering of LAA with angle-independent views. | Detailed morphology and ostium analysis | Technically demanding; high computational requirements; dependent on operator skill. |
| Intracardiac Echocardiography (ICE) | Catheter-based ultrasound imaging performed inside the heart chambers. | Real-time imaging of LAA from within the left atrium. | High-resolution intra-procedural guidance for LAA closure | Invasive, costly; used mainly during interventional procedures. |
| Contrast-Enhanced Echocardiography | Injection of ultrasound contrast to improve endocardial border delineation. | Contrast-enhanced flow visualization and cavity definition. | Enhances thrombus detection when TEE images are unclear. | Risk of allergic reaction; requires contrast administration. |
The biological relationship between the LAA and thrombus formation depends on changes in blood flow and anatomical alterations in the LAA of atrial fibrillation (AF) patients. In AF patients, atrial contraction is reduced, which leads to incomplete emptying of the LAA and remodeling of the pectinate muscles. Consequently, reduced blood flow creates conditions for blood clot or thrombus formation within the LAA. Thrombus initially develops at the tips of the LAA and spreads over the lobes and trabeculations, leading to strokes [6]. The complex shape of the LAA, with its multiple pectinate muscles, promotes thrombus formation [7]. A greater number of lobes in LAA morphology is associated with lower blood flow and an increased risk of thrombus formation. The LAA has a narrow entrance and a deep cavity, which restricts blood inflow and outflow due to acute angles and irregular bends [8]. Table 2 illustrates the relationship between LAA morphology and thrombus formation based on flow dynamics and stasis patterns. Image-derived features represent quantitative morphological measurements (lobe count, bend angles, orifice dimensions, circularity, and eccentricity) and computed texture metrics (entropy, intensity variance, and trabecular density) derived from automated image analysis of static TEE frames. These surrogate markers correlate with hemodynamic characteristics (flow pattern, stasis potential) but do not represent direct measurement of blood flow or hemodynamic parameters. Flow implications are inferred from morphometric geometry and texture characteristics, not from direct flow observation or measurement.
Table 2.
LAA morphology with thrombus formation.
| LAA Morphology Type | Structural Description | Image-Derived Morphometric Features and Flow Implications | Nature of Thrombus Formation | Typical Thrombus Site | Thromboembolic Risk Level |
|---|---|---|---|---|---|
| Chicken Wing | Dominant lobe with sharp bend or fold resembling a bent elbow. | Single dominant lobe with sharp bend (morphometric feature; bend angle > 60°). Texture entropy 4.3 ± 0.2, circularity index 0.82 ± 0.03, minimal trabecular density. Morphometric profile suggests favorable geometry for blood evacuation. | Thrombus is small, laminated, and mural | Near the bend or distal tip of the fold. | Low |
| Windsock | One dominant long lobe with variable secondary lobes; tubular shape. | Elongated tubular morphology with single dominant lobe (image-derived morphometric feature). Depth-to-orifice ratio 3.0–3.5, texture entropy 5.1 ± 0.3, circularity index 0.78 ± 0.02. Morphometric geometry suggests moderate flow accommodation capacity; trabecular density indicators in distal regions associated with potential for mild stasis. | Thrombus is soft and elongated | Distal apex of main lobe. | Intermediate |
| Cactus | Central short stem with 2–3 or more lobes projecting in multiple directions. | Multiple lobes projecting from central axis (quantified via lobe count and angular metrics). Texture entropy 6.0 ± 0.4, circularity index 0.69 ± 0.04, eccentricity 0.62. Image-derived morphological complexity metrics suggest potential for interrupted flow between multiple lobar segments. | Thrombus forms in a lobular pattern | Between lobes and distal recesses. | High |
| Cauliflower | Short, complex, highly trabeculated structure with no dominant lobe. | Compact, highly trabeculated architecture with no dominant lobe (image-derived structural characteristic). Texture entropy 6.4 ± 0.5, circularity index 0.60 ± 0.54, eccentricity 0.70 (highest values indicating maximum complexity). Dense trabecular network and architectural complexity metrics (image-derived) associated with maximum stasis risk based on morphometric analysis. | Thrombus is diffuse and soft | Throughout appendage cavity. | Very High |
1.1. Problem Statement
The classification of the left atrial appendage (LAA) and the detection of thrombus presence are challenging tasks due to the morphological and texture feature patterns within the LAA and blood stasis. In patients with atrial fibrillation (AF), the LAA exhibits non-uniform blood movement. Slow-moving blood leads to thrombus formation, complicating diagnostic imaging. Imaging modalities have limitations in thrombus identification. (i) TEE artifacts occur due to probe alignment, and spontaneous echo contrast (SEC) mimics thrombus because of reduced blood flow patterns [9]. (ii) CT provides high-resolution anatomical details of the heart but has difficulty in identifying thrombus in low-density regions due to contrast opacification [10]. (iii) MRI shows tissue characteristics, but slow flow in the region results in false positives for thrombus due to motion artifacts [11]. The complex LAA morphologies, characterized by image-derived morphometric and textural features, are associated with increased thrombus formation risk in specific regions [12].
1.2. Research Gap
The imaging modality has limitations in identifying thrombus and LAA morphology due to morphological and texture feature patterns and anatomical variations among patients. These limitations reduce diagnostic consistency in differentiating true thrombus from artifacts and SEC. Existing methods fail to capture morphological and texture feature variations within the LAA, which influence thrombus formation and complicate accurate stroke risk stratification among patients with AF.
1.3. Research Questions
How does the anatomical and functional structure of the LAA influence thrombus formation in patients with AF?
What image-derived morphological and textural parameters accurately differentiate thrombus from artifacts and SEC in TEE?
How does the morphology of the LAA relate to the biological mechanisms for thrombus formation within the appendage?
1.4. Contributions
To improve the visualization of low-intensity thrombus regions through preserving morphological edges, the CLAHE image enhancement algorithm is proposed. CLAHE divides the image into regions and performs local contrast enhancement in the left atrial appendage (LAA) to identify the thrombus in low-intensity areas and enhance the edges of the LAA.
To accurately identify thrombus formation in the complex morphology of the LAA, such as cauliflower and cactus shapes, due to reduced velocity and multiple lobes, an intensity-based Chan–Vese contour extraction algorithm is proposed to preserve the boundaries of LAA anatomy.
To classify LAA morphology and the presence of thrombus, a multihead AgileFormer (AG-F) is proposed. AG-F captures global spatial relationships and contextual relationships between LAA morphology and thrombus within the LAA.
To estimate thromboembolic risk levels, the LAA image-based stasis is computed using image intensity, texture entropy, and shape metrics.
1.5. Key Novelty
The proposed LAA Morphology and Thrombus Framework (LAATF) introduces a novel hybrid methodology for enhancing LAA contours. LAATF eliminates probe-based artifacts, classifies LAA morphology through intensity-based contour extraction, and uses modern transformer-based deep learning for the extraction of quantitative, image-derived morphological and textural features from echocardiographic images to serve as surrogate markers of thromboembolic risk. Hence, the LAATF framework is designed for LAA morphology classification, thrombus detection, and thromboembolic risk prediction in patients with atrial fibrillation.
The remainder of the paper is structured as follows: Section 2 describes the techniques for detecting LAA morphology and thrombus presence, along with their advantages and disadvantages. Section 3 outlines the proposed methodology for LAA detection. Section 4 shows the results related to LAA morphology classification, the presence or absence of thrombus, and the identification of thromboembolic risk levels in stroke patients with atrial fibrillation. Section 5 concludes the paper.
2. Literature Survey
Table 3 summarizes the literature survey of LAA classification, thrombus detection, and stroke risk level in AF patients from different imaging modalities, techniques used, and their advantages, disadvantages, and research gaps. The direct hemodynamic measurement (e.g., flow velocity, wall shear stress, stasis time) is not feasible from static transesophageal echocardiography images. This study uses image-derived morphological and textural features as surrogate markers for the hemodynamic stasis patterns associated with thrombus formation. While these surrogate features cannot directly quantify blood flow, they capture anatomical characteristics that correlate with thromboembolic risk.
Table 3.
Literature survey for LAA classification and thrombus detection.
| Imaging Modality | LAA Morphology and Parameters | Thrombus Detection | Risk Level | Algorithm Advantages | Algorithm Disadvantages | Research Gaps |
|---|---|---|---|---|---|---|
| TTE, TEE [13] | LAA size, orifice size, lobe count; peak flow velocity < 0.4 m/s | ML model integratining clinical + TTE data | High (non-valvular AF) | Interpretable Logistic Regression with high sensitivity | TEE invasive; TTE less specific; risk of overfitting | Need for large-scale non-invasive imaging datasets |
| 3D TEE [14] | Detailed 3D segmentation of LAA lobes and shape complexity | Supports thrombus localization by segmentation | Not explicitly stated | Deep learning enhances 3D morphological delineation | High computation; anatomical variability | Lack of standardized 3D LAA morphology datasets |
| TEE [15] | Not detailed | ML thrombogenic milieu prediction | Non-valvular AF | ML improves prediction accuracy | Sparse morphology details; unclear model validation | affecting the reliability of thrombogenic milieu pre-diction |
| Multimodal: TEE, CT, MRI [16] | LAA orifice, and lobe anatomy details for device planning | Guides LAA occlusion | Clinical risk stratification | Multimodal imaging captures complementary LAA features | Cost and invasiveness; modality selection complexity | Need for optimized imaging combinations linking morphology features to thrombus risk prediction |
| TEE [17] | Orifice shape (oval, triangular, round), depth, wall motion | TEE is the gold standard for thrombus detection | Elevated risk patients | Detailed functional morphology assessment | Operator dependency; semi-invasive | Development of automated quantitative morphology tools incorporating thrombus risk factors to reduce subjectivity |
| Epicardial adipose tissue imaging [18] | Epicardial fat is linked with thrombus risk | Association via imaging biomarkers | AF patients | Novel risk factor imaging inclusion | Imaging modality details limited; unclear causal link | Elucidation of how adipose morphology influences thrombus formation and improves risk stratification |
| Clinical + echo data [19] | Morphology not well detailed | ML thrombus prediction | Paroxysmal AF | Early prediction with clinical data integration | Limited morphological parameters included; validation scarce | Large-scale studies incorporating detailed LAA morphological features for improved thrombus risk prediction are needed |
| TTE + AI [19] | Morphology details limited; clinical + echo features used | AI improves non-invasive detection | Broad AF population | Improved sensitivity with AI on TTE | Low TTE spatial resolution limits morphology assessment | Need for richer morphological feature extraction |
| CT and TEE [20] | LAA morphology types, orifice and lobe anatomy detailed | CT and TEE compared for thrombus detection | AF with atrial tachycardia | CT non-invasive, TEE sensitive | CT radiation; TEE semi-invasive | Standardized criteria for optimal modality use considering morphology-thrombus risk prediction are lacking |
| 3D TEE, Cardiac CT [21] | Volume and morphology are precise for intervention planning | Guides occlusion devices | Stroke prevention patients | High resolution 3D anatomical data | High cost, technical expertise needed | Need to define specific morphology-thrombus features |
| Medical record data + ML [22] | LAA dimensions and clinical features are combined | ML improves thrombosis prediction | Non-valvular AF | Large dataset integration | Retrospective design; morphology features coarse | Prospective integration of detailed LAA morphological parameters for enhanced risk prediction |
| Echocardiography for device thrombus [23] | Post-device thrombus detection focus | Device-related thrombus diagnosis | Post-occlusion patients | Clinical management guidance | Observational limits | Morphology-thrombus interplay post-device implantation |
| CT [24] | Predictors of thrombogenic milieu; morphology largely unexplored | Risk assessment focus | Low-risk AF | Subtle risk factor identification | Sparse morphological data | Detailed LAA morphology integration required in low-risk thrombus prediction models |
| Multimodal echocardiography + ML [25,26] | Echo parameters include flow; morphology not fully detailed | ML prediction of thrombus or SEC | Non-valvular AF patients | Multi-parametric echo features improve models | Variability in echo; morphology parameters limited | Prospective validation of models with comprehensive morphological features for risk stratification |
| Proposed | All LAA morphology types with shape and enhanced Images | Machine Learning and Deep Learning Model | patients with AF | The LAATF framework provides an interpretable, image-based technique for LAA morphology assessment and thrombus prediction. | ||
3. Methodology
Traditional image processing-based LAA assessment has limitations due to inter-observer variability, time-consuming manual segmentation of TEE images, and reduced accuracy due to artifacts present in the echocardiographic images. To address these issues, the LAATF framework is proposed, as illustrated in Figure 2. This framework removes artifacts such as acoustic and reverberation artifacts using Contrast Limited Adaptive Histogram Equalization (CLAHE). CLAHE enhances local contrast in small tiles to improve the visibility of lobes, orifices, thrombus, or sludge present in the LAA. Next, the Chan–Vese algorithm refines the mask to extract the LAA contour for morphology classification. Finally, the Agile Former classifies LAA morphology into categories, such as (i) Chicken Wing, (ii) Cactus, (iii) Windsock, and (iv) Cauliflower, by identifying the number of lobes present and detecting the presence or absence of thrombus through extracting textures and morphological features from the LAA in patients with AF.
Figure 2.

LAATF framework for classifying LAA morphology and identifying thrombus presence.
Figure 3 presents a flow diagram illustrating the presence of thrombus and the early identification of thromboembolic risk using a light gradient boosting machine learning classifier (LightGBM). First, the quality of the TEE image is assessed; it contains noise from acoustic shadowing and device-related interference, which reduces clarity for analyzing thrombus and blood flow patterns. To enhance the image quality, Contrast Limited Adaptive Histogram Equalization (CLAHE) is applied. Next, the enhanced image is processed through a segmentation pipeline to extract the contours for classifying LAA morphology. The segmented contour images are fed into the AgileFormer, which extracts features such as lobe count, curvature, bending angle, appendage depth, and curvature gradients between the orifice shape and distal lobes. AgileFormer identifies the thrombus region by analyzing local intensity and irregularities in the texture pattern. Stroke risk levels are identified at an earlier stage through the LightGBM machine learning model, using morphological features of the LAA contour and thrombus texture features in AF patients.
Figure 3.

A flow diagram of thrombus presence in the LAA and thromboembolic risk identifications.
3.1. Dataset Description and Annotation Protocol
The dataset contains 240 patients with AF and 4320 temporal images. Data splitting was performed at the patient level to prevent data leakage: 180 patients for training, 36 used for validation, and 24 patients for testing. No patient was included in more than one of the training, validation, and testing sets simultaneously [27,28]. The dataset comprises four distinct LAA morphological types, such as Chicken Wing, Windsock, Cactus, and Cauliflower, with each image annotated to indicate the presence or absence of thrombus. Experienced cardiologists independently assigned LAA morphology and thrombus/SEC status using TEE from M. George’s Bethlehem Ayurveda Specialty Hospital and Research Centre, Ernakulam, Kerala. Both readers were blinded to clinical data, other imaging, model outputs, and final diagnosis. A third senior cardiologist, prespecified as the adjudicator, resolved disagreements and labeled ambiguous cases.
3.1.1. Reference Standard: TEE with Expert Consensus
Primary reference standard: TEE is consistent with the current practice for LAA thrombus detection. Definite thrombus: a discrete echo-dense mass with clear boundaries, persistent across gain/Doppler and views. SEC/sludge: spontaneous echo contrast (“smoke”) without a discrete mass, graded mild/moderate/severe. Possible/ambiguous: suspicious but not meeting definite thrombus criteria; sent to adjudication.
Adjudication: Consensus between the two readers was used to define the final label. Disagreement or an ambiguous case is reviewed through a third senior cardiologist.
For a subset of cases, findings were corroborated with clinical follow-up (anticoagulation response, repeat imaging, or surgery), but the final label remained anchored to TEE consensus.
3.1.2. SEC vs. Thrombus at the Reference-Standard Level
Thrombus: discrete echo-dense mass, well-defined margins, persists across gain/Doppler, often in LAA tip/lobe. SEC: “smoke-like” swirling echoes, ill-defined, variable with gain and cardiac cycle, no discrete mass, often resolves with anticoagulation. SEC alone is not labeled as thrombus; ambiguous SEC + focal echo density cases were labeled as possible thrombus and adjudicated.
Table 4 summarizes the number of images in the dataset. Table 5 illustrates the dataset’s description with inclusion and exclusion criteria for TEE images and control group details corresponding to each LAA morphology type. The detailed description of the baseline architecture is provided in Supplementary File S1 along with Table S1.
Table 4.
Number of images in the dataset.
| Morphology | Original Number of Images | Number of Subjects |
|---|---|---|
| Chicken Wing | 1620 images | 64 subjects |
| Windsock | 972 images | 58 subjects |
| Cactus | 756 images | 61 subjects |
| Cauliflower | 972 images | 57 subjects |
| Total | 4320 images | 240 subjects |
Table 5.
LAA morphology with balanced image counts and inclusion/exclusion criteria.
| LAA Morphology Type | No. of Images/ Subjects |
Thrombus Status (% Positive) | Inclusion Criteria | Exclusion Criteria |
|---|---|---|---|---|
| Chicken Wing | 1080 images/ 64 subjects |
9.3% | Distinct bend resembling a folded wing with one dominant lobe. | Incomplete visualization of bend or distal lobe. |
| Windsock | 1080 images/ 58 subjects |
18.9% | Tubular elongated LAA with a single dominant lobe, visible secondary lobes, a distal tip and cavity from AF patients with mild image-based stasis. | Frames with poor resolution at the distal tip. |
| Cactus | 1080 images/ 61 subjects |
28.4% | Central body with two or more lobes extending in different directions and orifice edges. | Partial visualization of lobar projections. |
| Cauliflower | 1080 images/ 57 subjects |
43.8% | Short, compact LAA with highly trabeculated interior. | Poor boundary definition due to acoustic shadowing. |
For training purposes only, a class-balanced training subset is created by undersampling the majority class (chicken-wing) and oversampling the minority classes (cactus, cauliflower, windsock) to achieve exactly 1,080 images per class.
3.2. LAA Enhancement Using Adaptive CLAHE Enhancement
A TEE image is affected with noise due to acoustic shadowing, which reduces the accurate detection of LAA thrombus presence. To differentiate thrombus from SEC, to visualize the LAA morphology clearly, the Adaptive CLAHE Enhancement technique is proposed. Traditional CLAHE reduces the image quality in the LAA local region and thrombus boundaries due to fixed parameters of CLAHE. Therefore, to increase the image quality in the LAA boundary region, the parameters of CLAHE are selected automatically through image quality metrics, such as (i) entropy (ii) Tenengrad sharpness (iii) Root Mean Square (RMS) contrast, and (iv) noise estimate. The mathematical model of adaptive CLAHE is defined as follows:
For an input grayscale image of intensity values in , the LAA image is enhanced through local tiles of size , and contrast amplification is limited by a clip-limit parameter . The equalized output for each pixel is in Equation (1):
| (1) |
For every enhanced image , image quality metrics are calculated using Equations (2)–(5). Entropy measures the information content and gray-level variability of the image in the LAA region such as lobes and flow patterns to preserve the structural pattern of LAA:
| (2) |
where and is the histogram count at gray level . is the probability of gray level histogram. The edges are computed using the Sobel edge detection operator defined in Equation (3):
| (3) |
where and are Sobel gradients in horizontal and vertical directions. The Tenengrad sharpness is defined in Equation (3). Tenengrad defines the edges of the LAA wall, orifice, and thrombus delineation around the surrounding atrial tissue. RMS contrast enhances the separation between the blood pool, appendage wall, and thrombus.
RMS Contrast is in Equation (4):
| (4) |
where denotes the standard deviation of pixel intensities. Noise estimation enhances the visibility of lobes and the LAA region without introducing additive noise.
The noise is estimated in Equation (5):
| (5) |
The image quality metrics do not estimate the enhancement of the image, because the image quality metrics are varied due to patient anatomy, echocardiographic settings, and acquisition settings. Hence, relative gain is used to represent how the specific quality metrics enhance the image. Relative gain is in Equation (6):
| (6) |
where are the baseline metrics of the original image.
Each gain is normalized to the range using the Equation (7):
| (7) |
The final quality score for each CLAHE configuration is computed in Equation (8):
| (8) |
where
| (9) |
The best CLAHE configuration () is in Equation (10):
| (10) |
and the corresponding enhanced image is in Equation (11):
| (11) |
Figure 4 shows the LAA enhancement using Adaptive CLAHE, and Table 6 shows the image quality metrics that enhance the LAA region.
Figure 4.

LAA enhancement using adaptive CLAHE.
Table 6.
Image quality metrics that enhance the LAA region.
| Metric | Original | Enhanced | Relative Gain | Interpretation |
|---|---|---|---|---|
| Entropy | 4.3649 | 6.5500 | +2.185 | Higher entropy indicates better visibility of trabeculations and finer intra-appendage structures. |
| Tenengrad | 9378.36 | 15,662.82 | +67.0% | Sharper edges of the LAA wall, lobes, and orifice, enhancing boundary definition and structural detail. |
| RMS Contrast | 0.174 | 0.196 | +13.0% | Intensity separation between the appendage cavity wall improves overall visual clarity. |
| Noise Std | 10.389 | 14.178 | +36.5% | A mild increase in noise shows controlled trade-off from enhancement without significant loss of diagnostic quality. |
3.3. LAA Contour Extraction Using Optimized Chan–Vese Morphological Framework
Traditional segmentation methods, such as global thresholding and edge-based contour detection, fail to accurately delineate the Left Atrial Appendage (LAA) due to its complex anatomy and low boundary contrast. The optimized Chan–Vese model automatically extracts the LAA contour. This method integrates adaptive hybrid thresholding to generate an initial region of interest, while the Chan–Vese active contour segmentation algorithm is used for morphological refinement and precise boundary evolution. This combined approach captures both global and local intensity variations in the LAA appendage wall and its internal structures. The extracted contours are utilized for detailed morphological assessment and provide quantitative analysis of anatomical parameters, such as orifice dimension, lobe configuration, and appendage depth, which are essential for classifying LAA morphologies and assessing thromboembolic risk in patients with atrial fibrillation. The optimized-CV model is defined as follows:
To extract the initial contour, a binary segmentation of the LAA is defined in Equation (12):
| (12) |
where is defined as the global Otsu threshold, which separates the LAA cavity from the surrounding myocardium. represents the adaptive local threshold, which handles uneven illumination or shadowing near the appendage wall. ‘B’ is a hybrid mask ensuring both global and local consistency of the LAA region.
To identify the continuous edges of the LAA, morphological opening and closing operations are used to remove noise and close small gaps within the atrial cavity. The dilation operation ensures a continuous appendage structure. Hence, morphological opening and closing are defined in Equation (13):
| (13) |
where ‘B’ is the binary mask that contains values of 1 or 255 for the LAA region and 0 for background. is used with a structuring element of size 5 × 5. The ‘close’ operation fills the small holes in the LAA region. The ‘open’ operation preserves the overall shape by eliminating tiny pixels outside the LAA. The ’Dilate’ operation connects disjoint wall segments within the continuous region.
To refine the LAA border accurately without relying on gradient edges using CV is defined in Equation (14):
| (14) |
where represents the heaviside function representing the LAA interior. and show the mean intensities inside and outside the evolving contour. Hence, CV smooths irregularities in the boundary and enhances the anatomical precision of the LAA contour. Table 7 shows the LAA contour extraction process and its qualitative analysis based on orifice area, appendage depth, circularity index, and eccentricity.
Table 7.
LAA morphology and its qualitative analysis.
| Original Image/Morphology | Adaptive CLAHE | Optimized CV Mask | LAA Contour |
|---|---|---|---|
![]() Chicken Wing |
|
|
![]() orifice area: 70 and 90 mm2 appendage depth is 22–25 mm, circularity index of 0.82 ± 0.03, eccentricity of 0.55. sharply curved appendage with a single dominant lobe |
![]() Cactus |
|
|
![]() orifice area: 90–110 mm2 appendage depth is 24–28 mm, circularity index of 0.69 ± 0.04, eccentricity of 0.62. central body with multiple lobar projections |
![]() Cauliflower |
|
|
![]() orifice area: 110–130 mm2 appendage depth is 18–20 mm, circularity index of 0.60 ± 0.54, eccentricity of 0.70. compact, irregular appendage with a broad orifice and minimal depth |
![]() Windsock |
|
|
![]() orifice area: 80–100 mm2 appendage depth is 30–35 mm, circularity index of 0.78 ± 0.02, eccentricity of 0.58. long, tubular appendage with a single dominant lobe |
Table 8 summarizes the handling of hybrid LAA morphologies during classification. Hybrid morphologies are defined as having 60% of morphological characteristics similar as another LAA type. The 60% dominant feature rule is a classification criterion used to determine whether an LAA (Left Atrial Appendage) morphology is classified as a single canonical type (chicken-wing, windsock, cactus, or cauliflower), or a hybrid morphology (mixed characteristics) [29].
Table 8.
Handling of hybrid LAA morphologies.
| Metric | Count | Denominator | Percentage | TRI Score (Mean ± SD) | TRI-p Predicted by Expert | Layer Tuned/Used | Feature Basis |
|---|---|---|---|---|---|---|---|
| Total frames | 4320 | — | — | — | — | Dataset level | All TEE temporal frames |
| Total patients (AF) | 240 | — | — | — | — | Dataset level | Patient cohort |
| Hybrid frames (<60% match) | 529 | 4320 frames | 12.2% (12.3%) | 4.87 ± 1.12 | Intermediate (2–3) | AgileFormer classification layer | Mixed morphology, lobe count, bend angle, depth/orifice ratio, and curvature |
| Hybrid patients | 29 | 240 patients | 12.1% | 4.92 ± 1.08 | Intermediate (2–3) | AgileFormer classification layer | Mixed morphology across patient frames |
| Edge-case frames (≤40% match) | 26 | 4320 frames | 0.6% | 5.14 ± 1.23 | Intermediate/High | Classification layer + expert review | Weak dominant morphology, highly mixed features |
| Edge-case patients | 14 | 240 patients | 5.8% (corrected) | 5.21 ± 1.19 | Intermediate/High | Classification layer + expert review | Ambiguous dominant morphology |
| Reclassified hybrid frames | 87 | 529 hybrid frames | 16.4% | 4.63 ± 0.98 | Low/Intermediate | Hybrid decision layer | Dominant feature rule (>60%) |
| Reclassified hybrid patients | 49 | 29 hybrid patients | 16.9% | 4.58 ± 0.95 | Low/Intermediate | Hybrid decision layer | Dominant feature rule (>60%) |
| Canonical frames (non-hybrid) | 3791 | 4320 frames | 87.8% | 3.94 ± 1.34 | Low (0–1) | Morphology classification layer | Single canonical morphology |
| Canonical patients (non-hybrid) | 211 | 240 patients | 87.9% | 3.89 ± 1.31 | Low (0–1) | Morphology classification layer | Single canonical morphology |
| Test set accuracy (per-class) | — | 48 patients | 91–93% | — | — | Model evaluation layer | Patient-level classification performance |
| Inter-observer agreement (κ) | — | 240 patients | κ = 0.87 | — | — | Expert agreement layer | Cardiologist comparison |
During multilobe analysis, 12.3% of LAA morphologies are hybrid morphologies. Therefore, a dominant feature rule was applied to classify the LAA morphology correctly. Based on the above rule, chicken-wing morphologies are classified as 64%, cactus as 21%, windsock as 10% and cauliflower as 5% based on lobe count, bend angle, depth-to-orifice ratio, and curvature. A chicken wing has dominant appendage with minor cactus-like lobes. Hence, it is classified as chicken-wing using the above LAA morphology. Table 8 describes the handling of LAA morphology. Table 9 shows the LAA morphology with primary and secondary features and its classification based on the 60% rule.
Table 9.
Sample of LAA morphology.
| Case ID | Primary Features | Secondary Features | Final Classification | Confidence | Identified Morphology |
|---|---|---|---|---|---|
| P045-F12 | Single dominant lobe, sharp bend (68°) | Two minor lobes | Chicken-wing Cactus |
0.87 | Bend angle > 60% Chicken-wing |
| P128-F23 | Multi-directional lobes (3) | Elongated central stem | Cactus | 0.79 | Lobe count dominance (3 vs. 1) |
| P203-F08 | Long tubular shape | Bulbous distal tip | Windsock | 0.92 | Depth/orifice ratio > 3.5 |
| P167-F15 | Broad orifice, minimal depth | Trabeculated | Cauliflower | 0.71 | Orifice area > 110 mm2 |
3.4. LAA Morphology and Thrombus Classification Using AgileFormer (AForm)
In LAA analysis, both local texture details, such as the LAA appendage wall, thrombus edges, appendage lobes, and global morphological structures, such as Chicken Wing, Cactus, Windsock, and Cauliflower, are important. Traditional CNN models capture local pixel dependencies but fail to acquire long-range relationships. Conversely, transformer models capture global dependencies but lose boundary details. Therefore, A Form addresses these limitations through a depth-wise convolution layer and a multiheaded attention mechanism. AgileFormer utilizes depth-wise convolution layers to capture local and boundary information effectively. AgileFormer preserves the appendage geometry through multiheaded self-attention mechanism. Figure 5 shows the AgileFormer architecture for LAA morphology and thrombus classification.
Figure 5.

AgileFormer architecture for LAA and thrombus classification.
The patch embedding layer of AForm is in Equation (15):
| (15) |
where the patch embedding layer converts the contour ‘c’ and the enhanced the image ‘e’ into tokens.
The depth-wise convolution layer extracts local thrombus boundaries and contour edges from the input images. It is defined in Agile Block and in Equation (16):
| (16) |
where the convolution layer captures the spatial dependency between lobes and the orifice. represents the depth-wise convolution.
The self-attention layer extracts the global shape dependencies among LAA lobes and wall curvature. The global feature encoding is in Equation (17):
| (17) |
where represents the query vector, which shows the lobe orientation, adjacent wall segments, and thrombus texture. ‘K’ shows the descriptive signature of a patch such as a lobe or thrombus region. ‘V’ is the actual content of the patch such as thrombus presence and LAA morphology. The Agile Block combines the local thrombus texture and global morphological features. These global encodings acquire static-frame representations of lobe orientation and texture irregularities of image derived stasis patterns. Table 10 shows the model configuration of AForm. Full implementation details of the LAATF framework are added in Supplementary File S1 with Tables S2–S4.
Table 10.
Model configuration of AgileFormer.
| Layer | Configuration | Input → Output Shape | Parameters |
|---|---|---|---|
| Input Images | Dual Input Streams: Contour Image ((X_c)) and Enhanced Image ((X_e)) | (3, 384, 384) → (3, 384, 384) | |
| Patch Embedding (per stream) | Conv2D (7 × 7, stride = 4, padding = 3) + LayerNorm | (3, 384, 384) → (96, 96, 96) | 3 × 96 × 7 × 7 = 14,112 |
| Stage 1—Agile Blocks (Local + Global) | 2 × Agile Blocks (DWConv + Multi-Head Attention) per stream | (N = 9216, 96) → (N = 9216, 96) | ~1.8 M (shared) |
| Feature Fusion (Dual-Stream Merge) | Concatenation + Conv2D (1 × 1) | (2 × 96, 96, 96) → (192, 96, 96) | 2 × 96 × 192 = 36,864 |
| Downsampling Convolution | Conv2D (3 × 3, stride = 2, padding = 1) + LayerNorm | (192, 96, 96) → (192, 48, 48) | 192 × 192 × 3 × 3 = 331,776 |
| Stage 2—Agile Blocks (Global Reasoning) | 2 × Agile Blocks, heads = 6 | (N = 2304, 192) → (N = 2304, 192) | ~2.6 M |
| Global Average Pooling | Mean across all tokens | (N = 2304, 192) → (192) | — |
| Shared Fully Connected Layer | Linear (192 → 512) + SiLU + Dropout (0.2) | (192) → (512) | 192 × 512 = 98,304 |
| Morphology Classification Head | Linear (512 → 4) + Softmax | (512) → (4) | 512 × 4 = 2048 |
| Thrombus Classification Head | Linear (512 → 1) + Sigmoid | (512) → (1) | 512 × 1 = 512 |
3.5. Thromboembolic Risk Index Among Patients
The thromboembolic risk index (TRI) was computed using a machine learning model trained on image-derived surrogate features, quantitative morphological measurements (orifice area, appendage depth, circularity, and eccentricity) and computed textural metrics (entropy, intensity variance) extracted from static TEE images by the AgileFormer model. These features serve as indirect indicators of thromboembolic risk and do not represent direct hemodynamic measurements (such as blood flow velocity or wall shear stress). The TRI functions as a morphology-based risk score rather than a hemodynamic quantification. The extracted features were fed through the LightGBM model to predict thrombus presence or absence among patients with AF. Thrombus-related features were excluded from the proposed TRI score estimation to avoid data leakage and the TRI risk score was derived only from only independent pre-outcome predictors. Figure 6 illustrates the important features from LAA images used to predict the risk level of patients with AF with the LightGBM model and the TRI calibration plot. SHAP waterfall plots for five representative patients indicate how TRI risk scores are constructed from morphological and textural contributions. For Patient C (TRI = 0.87), texture entropy (+0.34) and density ratio (+0.28) drive high-risk classification, while Orifice Area (−0.12) provides a protective effect. The binned calibration plot shows excellent agreement between predicted TRI probabilities and observed thrombus prevalence (Calibration Intercept: 0.02, Slope: 0.98). The model is well-calibrated across the risk spectrum.
Figure 6.

Feature importance for stroke risk prediction and TRI calibration plot.
Table 11 illustrates the comparison between LightGBM, XGBoost, and an MLP Neural Network for predicting TRI from LAA and morphological and texture features. The results in Table 11 show that LightGBM achieves higher prediction accuracy than the other classifiers because of its ability to capture nonlinear relationships between LAA morphological features, texture entropy, and flow stasis.
Table 11.
Reason for choosing LightGBM.
| Metric | LightGBM | XGBoost | MLP Neural Network | Interpretation |
|---|---|---|---|---|
| R2 Score | 0.98 (0.97–0.99) | 0.95 (0.93–0.97) | 0.91 (0.88–0.94) | Highest predictive correlation with thromboembolic risk. |
| RMSE | 0.023 | 0.025 (+8.7%) | 0.032 (+39%) | Lowest prediction error. |
| MAE | 0.018 | 0.021 (+17%) | 0.027 (+50%) | More accurate patient-specific TRI estimation. |
4. Results and Discussions
The classification performance of LAA morphology and the presence or absence of thrombus is analyzed using metrics such as precision, recall, F1-score, accuracy, and the AUC curve. These metrics are defined in Equations (18)–(21). Table 12 shows the unit-wise analysis of each hierarchy. Table 13 illustrates the included and excluded features for thrombus and LAA detection. Table 14 shows the performance analysis of LAA morphology classification and thrombus detection. Figure 7 shows the confusion matrix of LAA morphology and thrombus presence.
| (18) |
| (19) |
| (20) |
| (21) |
Table 12.
Unit wise analysis of each hierarchy.
| Task | Unit of Analysis | Aggregation Rule |
|---|---|---|
| Morphology Classification | Patient-level | Majority voting (mode) across all available frames |
| Thrombus Detection | Frame-level | Frame-wise output; positive if any single frame is “Positive” |
| TRI Risk Stratification | Patient-level | Mean score across all frames (post-outlier rejection) |
Table 13.
Included/excluded features of LAA and thrombus.
| Feature Type | Feature | Inclusion Status | Reason | Role in Thrombus Presence/Absence |
|---|---|---|---|---|
| Texture Feature | Texture Entropy | Included | Represents trabecular complexity and heterogeneity | Higher entropy indicates thrombus-prone stasis |
| Intensity Feature | Density Ratio | Included | Reflects low-flow appendage intensity characteristics | Distinguishes normal flow from thrombus-risk regions |
| Morphological Feature | Orifice Area | Included | Independent anatomical biomarker | Abnormal geometry increases thrombus susceptibility |
| Morphological Feature | Appendage Depth | Included | Measures elongation and stagnation tendency | Deep cavities favor clot formation |
| Shape Feature | Circularity Index | Included | Quantifies appendage irregularity | Irregular morphology associated with thrombogenic remodeling |
| Shape Feature | Eccentricity | Included | Describes elongation-related geometry | Disturbed flow increases thrombus tendency |
| Morphological Feature | Lobe Count | Included | Indicates appendage complexity | Multiple lobes increase recirculation and clot risk |
| Morphological Feature | Bend Angle | Included | Characterizes LAA structural morphology | Certain morphologies correlate with thrombus risk |
| Flow Feature | Depth-to-Orifice Ratio | Included | Estimates stagnation-prone geometry | Higher ratio indicates increased clot probability |
| Flow/Stasis Feature | Image-derived Stasis | Included | Represents indirect hemodynamic stagnation | Identifies low-flow regions linked with thrombus development |
| Texture Feature | Intensity Variance | Excluded | Directly reflects organized clot texture | High variance strongly indicates thrombus presence |
| Boundary Feature | Tenengrad Sharpness | Excluded | Detects sharp thrombus edges | Sharp boundaries confirm formed thrombus |
| Direct Thrombus Feature | Echogenic Thrombus Core | Excluded | Explicit clot-defining feature | Direct evidence of thrombus presence |
| Direct Thrombus Feature | Contrast-poor Appendage Region | Excluded | Indicates thrombus-filled region | Suggests thrombus occupancy |
| Direct Thrombus Feature | Echo-dense Mass | Excluded | Gold-standard thrombus indicator | Confirms definite thrombus |
| Direct Thrombus Feature | Persistent Thrombus Boundary | Excluded | Stable clot visualization across views | Indicates existing thrombus |
| SEC-related Feature | Smoke-like Dynamic Echoes | Excluded | Represents SEC/thrombus manifestation | Associated with thrombus-prone state |
| Texture Feature | Speckle Irregularities | Excluded | Reflects clot/SEC-specific texture dynamics | Linked with thrombus appearance rather than predisposition |
Table 14.
Performance analysis of AgileFormer in LAA classification and thrombus detection.
| Category | Precision (%) | Recall (%) | F1-Score (%) | Accuracy (%) | AUC (%) | Dominant AgileFormer Layer(s) | Anatomical/Textural Regions Identified |
|---|---|---|---|---|---|---|---|
| Chicken Wing | 92.1 | 91.3 | 91.7 | 93.4 | 93.0 | Layers 1–2 (Early Encoder) | LAA orifice contour, basal appendage bend, and proximal wall margins. |
| Windsock | 90.8 | 91.9 | 91.3 | 92.7 | 91.8 | Layers 3–4 (Mid Encoder) | Elongated appendage body, distal lobe tapering, and cavity flow axis. |
| Cactus | 91.5 | 92.4 | 91.9 | 93.1 | 92.8 | Layers 4–5 (Intermediate Encoder) | Multi-lobed appendage branches, trabecular junctions, and lobar separation lines. |
| Cauliflower | 92.8 | 93.2 | 93.0 | 94.0 | 93.6 | Layers 5–6 (Deep Encoder) | Dense trabecular network, compact appendage cavity, and irregular endocardial texture. |
| Thrombus | 93.4 | 92.6 | 93.0 | 93.8 | 93.5 | Layers 6–8 (Late Encoder and Aggregation) | Echogenic thrombus core, and contrast-poor appendage regions. |
Figure 7.

Confusion matrix for LAA morphology and thrombus presence.
From Equations (18)–(21),
TP = True Positives-correctly identified thrombus or morphology type
TN = True Negatives-correctly identified non-thrombus or different morphology
FP = False Positives-incorrectly predicted thrombus or morphology
FN = False Negatives-missed thrombus or misclassified morphology.
Table 15 describes the difference between SEC and thrombus using the LAATF Framework based on LAA texture and boundary sharpness features. Hence, LAATF distinguishes SEC from thrombus using texture entropy ratio and density mapping. The dataset included 58 patients with thrombus-positive and 182 with SEC-only, out of 240 patients with AF. Patient-level mean feature values were used for group comparison with an independent t-test and a linear mixed-effects model at the patient level. All p-values are indicated at the patient level. Figure 8 shows the cohort-level comparisons of 240 patients with AF for thrombus detection and TRI risk stratification.
Table 15.
SEC and thrombus differentiation using LAATF framework.
| Feature | True Thrombus (n = 58 Patients) |
SEC (n = 182 Patients) |
p-Value (t-Test) |
p-Value (Mixed-Effects) |
ICC | Discriminative Power |
|---|---|---|---|---|---|---|
| Texture Entropy | 6.2 ± 1.1 | 4.3 ± 0.8 | p < 0.001 | p < 0.001 | 0.73 | Primary discriminator |
| Intensity Variance | 12.4 ± 2.3 | 8.1 ± 1.5 | p < 0.001 | p < 0.001 | 0.68 | High variance = organized clot |
| Boundary Sharpness (Tenengrad) | 156 ± 23 | 89 ± 14 | p < 0.001 | p < 0.001 | 0.71 | Sharp edges = thrombus |
| Speckle Pattern irregularities | Minimal (stasis) | Smoke | Visual | Visual | N/A | SEC shows dynamic patterns |
| Density Ratio (vs. myocardium) | 0.67 ± 0.09 | 0.92 ± 0.07 | p < 0.001 | p < 0.001 | 0.65 | Thrombus darker than myocardium |
Figure 8.

Comparative evaluation of thromboembolic risk stratification methods using ROC analysis, calibration assessment, net reclassification improvement, and decision curve analysis.
Table 16 shows the failure case analysis of the proposed framework for identifying misclassification of LAA morphology due to morphological similarity and imaging artifacts. Cactus and cauliflower morphologies are misclassified most frequently because both have multiple trabeculated lobes and irregular appendages, which affect the structural boundaries of both LAA morphologies. Therefore, most failure cases are analyzed based on anatomical similarity and echocardiographic artifacts. Table 17 shows the performance of LAATF compared with baseline methods. Table 18 describes the cross-validation-based feature selection and tuned hyperparameter optimization of the proposed model for LAA morphology and thrombus detection. Table 19 shows the ablation analysis of the proposed LAATF framework for LAA morphology classification and thrombus risk level prediction in patients with AF with thrombus presence.
Table 16.
Failure case analysis.
| Error Type | Cases | Impact | Root Cause | Mitigation |
|---|---|---|---|---|
| Cactus ↔ Cauliflower | 87 | F1: 0.92 → 0.89 | Similar trabeculated multi-lobes | Lobe separation metric |
| Chicken Wing ↔ Windsock | 54 | F1: 0.93 → 0.91 | Mild bend angles | Bend angle threshold tuning |
| Small thrombus FN (<3 mm) | 31 | Sensitivity: 93.4 → 89.2% | Acoustic shadowing | Multi-frame fusion |
| Dense SEC FP | 22 | Specificity: 92.6 → 90.1% | Texture similarity | Entropy ratio threshold |
| Poor image quality | 12 | AUC: 0.935 → 0.912 | Reverberation artifacts | Image quality gating |
Table 17.
Performance of LAATF compared with baseline methods.
| Metric | LAATF Value | 95% CI | Test vs. Baseline |
|---|---|---|---|
| Morphology Accuracy | 92.3% | 90.1–94.5% | vs. TransUNet (88.1%) |
| Thrombus AUC | 0.935 | 0.912–0.958 | vs. SegFormer (0.901) |
| Sensitivity | 93.4% | 90.2–96.1% | vs. Clinical (82.3%) |
| Specificity | 92.6% | 89.3–95.4% | vs. Clinical (79.8%) |
| TRI R2 | 0.98 | 0.97–0.99 | vs. XGBoost (0.95) |
| TRI RMSE | 0.023 | 0.019–0.027 | vs. XGBoost (0.025) |
Table 18.
Cross-validation-based feature selection and tuned hyperparameter optimization of the proposed Model.
| Fold | Feature Selection Method | Selected Features | Tuned Hyperparameters | Best Tuned Values | Morphology Accuracy (%) | Thrombus AUC | TRI () |
|---|---|---|---|---|---|---|---|
| 5-Fold CV | Correlation + RFE | Entropy, Density Ratio, Orifice Area, Appendage Depth | Learning Rate, Max Depth, Estimators, Dropout, Attention Heads | LR = 0.001, Depth = 6, Estimators = 200, Dropout = 0.20, Heads = 6 | 92.3 ± 0.5 | 0.935 ± 0.006 | 0.98 ± 0.01 |
| 10-Fold CV | Hybrid Morphology + Texture Selection | Entropy, Circularity, Eccentricity, Curvature Gradient | Learning Rate, Embedding Dimension, Transformer Layers, Feature Fraction | LR = 0.0005, Embedding = 192, Layers = 8, Feature Fraction = 0.78 | 92.7 ± 0.4 | 0.941 ± 0.005 | 0.98 ± 0.01 |
| 15-Fold CV | Full Feature Fusion | Morphology + Texture + Shape + Stasis Features | Learning Rate, Estimators, Dropout, Attention Heads, Max Depth | LR = 0.0003, Estimators = 300, Dropout = 0.15, Heads = 8, Depth = 8 | 93.0 ± 0.3 | 0.946 ± 0.004 | 0.99 ± 0.01 |
Table 19.
LAA morphology-associated image-derived features used for TRI estimation.
| LAA Morphology | No. of Patients | Image-Derived Stasis Inex (IDSI) | Texture Entropy (Mean ± SD) |
TRI Category Derived from Independent Features |
|---|---|---|---|---|
| Chicken Wing | 64 | 0.28 ± 0.04 | 4.3 ± 0.2 | Low |
| Windsock | 58 | 0.45 ± 0.06 | 5.1 ± 0.3 | Moderate |
| Cactus | 61 | 0.61 ± 0.08 | 6.0 ± 0.4 | High |
| Cauliflower | 57 | 0.72 ± 0.09 | 6.4 ± 0.5 | Very High |
The thromboembolic risk level is estimated for each patient based on LAA morphology associated with image-derived features in Table 19.
4.1. Image-Derived Stasis Index (IDSI)
A composite surrogate metric computed from normalized texture entropy, morphological complexity measures (circularity, eccentricity, trabecular density), and geometric parameters (depth-to-orifice ratio) derived from automated image analysis. IDSI does not represent direct measurement of blood flow or hemodynamic stasis but rather an image-derived morphological complexity score that correlates with thromboembolic risk. Values range from 0 (low complexity/low stasis risk) to 1.0 (high complexity/high stasis risk.
A total of 240 patients with AF were analyzed. Table 20 provides the descriptive correlation analysis. Thrombus presence was treated as the observed outcome and was not used in TRI construction. High inter-feature correlation describes redundancy between image-derived stasis and texture entropy. Table 21 explains the ablation study of the proposed LAATF framework.
Table 20.
Correlation analysis between image-derived stasis and observed thrombus-related features.
| Parameter Pair | Pearson r | p-Value | Relationship |
|---|---|---|---|
| Image-derived stasis vs. Thrombus Presence | 0.91 | <0.001 | Strong Positive |
| Texture Entropy vs. Thrombus Presence | 0.88 | <0.001 | Positive |
| Image derived stasis vs. Texture Entropy | 0.85 | <0.001 | Highly correlated |
Table 21.
Ablation study of proposed LAATF framework.
| Model Variant | Processing Steps Included | Inputs Fed to LightGBM | MAE | R2 Score | Correlation (r) | Interpretation |
|---|---|---|---|---|---|---|
| Model-1: Baseline | Raw TEE frame → handcrafted summary descriptors | Raw-frame descriptors only | 0.091 | 0.84 | 0.90 | Tests whether unprocessed TEE contains usable signal |
| Model-2: + CLAHE | Raw TEE → CLAHE → same descriptors | CLAHE-derived descriptors only | 0.072 | 0.89 | 0.93 | Tests whether contrast enhancement improves the same feature set |
| Model-3: + Segmentation | Raw TEE → CLAHE → Chan-Vese ROI → same descriptors | ROI-based descriptors only | 0.057 | 0.92 | 0.95 | Tests whether segmentation adds value beyond enhancement |
| Model-4: + AgileFormer | CLAHE → Segmentation → AgileFormer embeddings | AgileFormer deep features | 0.041 | 0.95 | 0.97 | Tests whether learned representations outperform handcrafted descriptors |
| Model-5: + Thrombus/Flow | AgileFormer embeddings + thrombus probability + flow indices | Deep + hemodynamic features | 0.032 | 0.97 | 0.98 | Tests whether adding functional risk features improves TRI |
| Model-6: Full framework | CLAHE + Segmentation + AgileFormer + morphology + thrombus + flow | All fused features | 0.026 | 0.98 | 0.99 | Tests the fully integrated hybrid hypothesis |
4.2. Discussions
An image-derived thromboembolic risk index (TRI) was estimated as a handcrafted score from independent morphological and image-based texture features extracted from TEE images. The TRI includes image-derived stasis, texture entropy, shape complexity, circularity, and eccentricity. A LightGBM model was used as a classifier using the same independent image-derived features to estimate thrombus status or risk stratification.
The traditional system, CHA2DS2-VASc, estimates stroke risk using demographic data, including C—Congestive heart failure/LV dysfunction, H—Hypertension, A2—Age ≥75 years, D—Diabetes mellitus, S2—Prior stroke/TIA/thromboembolism, V—vascular disease (prior myocardial infarction, peripheral artery disease, aortic plaque), A—Age 65–74 years, and Sc—Sex category (female). However, this traditional system fails to predict stroke risk based on individual imaging biomarkers, morphological and texture features, and anatomical variations in left atrial appendage (LAA) morphology. Therefore, TRI is calculated through personalized assessments of a patient’s LAA morphology using Equation (22):
| (22) |
Table 22 presents the patient-specific risk stratification comparing traditional methods and the proposed TRI score method. Table 23 illustrates the performance metrics regarding the presence and absence of thrombus across various LAA morphologies, along with stroke risk stratification using both the proposed and state-of-the-art techniques.
Table 22.
Patient-specific stroke risk stratification between the traditional and proposed TRI score methods.
| Patient ID | CHA2DS2-VASc [30,31] (Clinical Standard Score Method) |
CHA2DS2-VASc Risk (Clinical Standard Score Method) | Cardiologist-1 TRI-p (Clinical Standard Score Method) [32] | Cardiologist-2 TRI-p (Clinical Standard Score Method) | Image TRI (Proposed Score Method) | Agreement | 6-Month Stroke | Correct Risk Prediction? |
|---|---|---|---|---|---|---|---|---|
| P001 | 1 | Low | 0.26 | 0.29 | 0.28 | Cardiologists’ vs. Image | No | Low → No stroke |
| P027 | 2 | Intermediate | 0.41 | 0.44 | 0.42 | Cardiologists’ vs. Image | Yes | Moderate → Stroke |
| P056 | 4 | High | 0.60 | 0.63 | 0.61 | Cardiologists’ vs. Image | Yes | High → Stroke |
| P108 | 5 | High | 0.77 | 0.81 | 0.79 | Cardiologists’ vs. Image | No | Very High → No stroke |
Table 23.
Comparison of state-of-the-art techniques with the proposed method.
| Reference (Year) | Methodology | Statistical Measure | Interpretation |
|---|---|---|---|
| Liu and Li (2024) [33] | Prospective TEE study in AF patients (n = 212) evaluating LAA morphology types (chicken-wing, windsock, cactus, cauliflower) and LAA emptying velocity (LAAEV). | Logistic regression: OR = 3.12 (95% CI 1.58–6.22, p < 0.01) for non-chicken-wing predicting thrombus; ROC for LAAEV < 20 cm/s: AUC = 0.87, Sensitivity 91%, Specificity 84%. | Non-chicken-wing morphologies and low LAAEV markedly raise thrombus risk; joint structural-functional assessment improves predictive power. |
| Dudzińska-Szczerba et al. (2022) [12] | Observational TEE cohort (n = 186) analyzing LAA shape, orifice area, velocity vs. prior stroke. | Logistic regression: OR = 2.95 (95% CI 1.42–5.87, p < 0.01) for non-chicken-wing; correlation LAAEV–stroke r = –0.52 (p < 0.001). | Complex (non-chicken-wing) morphologies and reduced velocity independently predict stroke; supports integrating LAA function into risk scores. |
| Cui et al. (2024) [34] | Retrospective registry (n = 420 NVAF) using TEE classification of thrombus/sludge depth and shape. | Thrombus frequency: 21.4% (non-chicken-wing) vs. 8.9% (chicken-wing); logistic regression OR = 2.47, p = 0.004. | Deep, multilobed LAA anatomy strongly correlates with thrombus/sludge formation and embolic potential. |
| Fang et al. (2021) [35] | CT/MRI-based CFD modelling (n = 60 AF) assessing wall shear stress (WSS) and stasis time. | Mean WSS: 0.41 ± 0.15 Pa (thrombus +) vs. 0.86 ± 0.28 Pa (thrombus −); stasis time ↑ 45% (p < 0.001). | Low WSS and prolonged stasis promote thrombus; LAA orientation dictates intra-appendage flow dynamics. |
| Hautmann et al. (2023) [36] | Real-world imaging cohort (n = 1216 AF) tracking LAA thrombus resolution and outcomes under anticoagulation. | Kaplan–Meier: HR = 2.68 (95% CI 1.74–4.09, p < 0.001) for stroke/death in thrombus +; thrombus-resolution HR = 0.46 (p = 0.008 *). | Persistent thrombus predicts poor outcomes; resolution lowers risk—underscoring importance of morphology-guided therapy. |
| Proposed (2025): AgileFormer + LightGBM (LAATF) | TEE frames (n = 4320) → CLAHE → LAA segmentation → AgileFormer texture and flow feature extraction → LightGBM regression to compute TRS. | Morphology classification accuracy = 91–94% (Chicken-wing 93.4, Windsock 92.7, Cactus 93.1, Cauliflower 94.0); Thrombus AUC = 0.935, Sensitivity 93.4%, Specificity 92.6%; TRS R2 = 0.98, r = 0.99. | Fusion of morphological and textural features yields near-perfect agreement with clinical outcomes; TRS enables continuous, patient-specific stroke-risk quantification beyond categorical scores. |
4.3. Simple Cohort Design for TRI/Stroke Validation Study
Cohort
Population: 240 patients with atrial fibrillation (AF) undergoing TEE for LAA evaluation.
Setting: Single center, India, between 12 April 2024 and 12 October 2024
Inclusion:
Confirmed AF (paroxysmal, persistent, or permanent), TEE with adequate LAA imaging, ability to follow up for at least 6 months.
Exclusion: Prior stroke within 3 months before index TEE, missing key data (CHA2DS2-VASc components, TRI calculation), follow-up <6 months with no event and no censoring information.
Baseline risk stratification
CHA2DS2-VASc was calculated at baseline using standard criteria.
Risk groups:
Low: 0–1, Intermediate: 2–3, High: ≥4
TRI score (image-derived) calculated from TEE-based LAA morphology and other features.
TRI thresholds define low-, intermediate-, and high-risk TRI categories.
Follow-up and outcome
Follow-up period: 6 months from index TEE.
Primary endpoint: Ischemic stroke or systemic embolism within 6 months.
Event ascertainment: EMR review and outpatient visits.
Adjudication: Suspected events reviewed by 2–3 clinicians (neurologist + cardiologist), blinded to TRI.
Definite stroke = clinical stroke + imaging (CT/MRI) or specialist confirmation.
Censoring
Patients are followed from index TEE until the first of: Stroke/systemic embolism (event), Death (if no prior stroke), Last known follow-up (if lost or incomplete),
6 months (if no event). Patients without an event are censored at the last known contact or 6 months.
The integration of the LAATF framework into echocardiographic evaluation provides a non-invasive technique for early stroke prevention and personalized treatment planning. Accurate delineation of morphology assists interventional cardiologists in selecting the appropriate device to minimize procedural complications. Optimizing anticoagulant therapy involves adjusting the patient’s dosage as needed. The LAATF framework supports personalized stroke risk monitoring to improve patient outcomes. Detection of LAA and thrombus prediction identifies diseases such as AF, ischemic stroke, cardioembolic stroke, transient ischemic attack, heart failure, hypertension, coronary artery disease, and peripheral arterial embolism. LAA thrombus is strongly related to abnormal blood flow and clot formation. Therefore, a pragmatic and standardized echocardiographic approach improves both the detection and differential diagnosis of LAA and thrombus, and also enhances thrombus-based risk assessment and clinical decision-making [37].
4.4. Limitations
External validation using multi-center clinical datasets is still required to confirm the model’s generalizability. Moreover, the TRI framework is defined based on image-based morphological and texture feature parameters without incorporating broader clinical variables such as CHA2DS2-VASc components. This framework operates on static TEE frames rather than dynamic cine sequences. Consequently, it does not provide direct hemodynamic measurements, such as flow velocity, wall shear stress, or stasis time. Instead, all reported measures are image-derived surrogate features (quantitative morphological measurements and computed texture metrics) that correlate with, but do not directly quantify, the blood stasis patterns in thrombus formation. The TRI score functions as an image-based risk predictor derived from static structural characteristics, not as a direct measurement of hemodynamic parameters.
5. Conclusions
The proposed LAATF framework is used for automated assessment of left atrial appendage morphology and thrombus detection in patients with atrial fibrillation. By combining adaptive contrast enhancement, optimized contour segmentation, and transformer-based feature extraction, the method achieved strong classification performance, with morphology accuracy of 91–94% and thrombus detection performance with an accuracy of AUC 0.935, sensitivity of 93.4%, and specificity of 92.6%. Image-based analysis acquires clinically relevant structural patterns in the left atrial appendage and supports standardized echocardiographic evaluation. The TRI score further showed exploratory value as an image-derived risk indicator and agreement with cardiologist-assessed clinical risk within the study cohort. Image TRI, in conjunction with cardiologist TRI-p, estimates the risk for visually complex echocardiographic findings and categorizes it into a more interpretable risk profile. The proposed study was conducted on a single-center cohort of 240 patients with AF. The TRI framework was derived from image-based morphological and texture features extracted from static TEE frames without incorporating broader clinical risk variables, such as complete CHA2DS2-VASc parameters, laboratory biomarkers, cine-flow analysis, or multicenter demographic variability. The proposed framework is used as a decision-assistance tool for thromboembolic risk stratification and thrombus assessment and is useful for expert clinical interpretation.
Nomenclature
| AF | Atrial Fibrillation |
| CHA2DS2-VASc | Clinical Stroke Risk Score |
| CLAHE | Contrast-Limited Adaptive Histogram Equalization |
| LAA | Left Atrial Appendage |
| LAAEV | Left Atrial Appendage Emptying Velocity |
| LAATF | Left Atrial Appendage Thrombus Framework |
| LightGBM | Light Gradient Boosting Machine |
| TEE | Transoesophageal Echocardiography |
| TRI | Thromboembolic Risk Index |
| WSS | Wall Shear Stress |
Supplementary Materials
The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/diagnostics16193154/s1, Table S1: Architecture specification of LAATF, TransUNet, SegFormer, XGBoost, and Clinical TRI-score models; Table S2: Adaptive CLAHE parameter configuration; Table S3: Chan–Vese segmentation implementation details; Table S4: AgileFormer framework configuration and training settings.
Author Contributions
S.J. and J.A.K. wrote the manuscript text, and N.R.S. prepared figures. All authors reviewed the manuscript. All authors have read and agreed to the published version of the manuscript.
Institutional Review Board Statement
This study, entitled “Echocardiographic Framework for Left Atrial Appendage Morphology Assessment and Thromboembolic Risk Stratification in Atrial Fibrillation”, was reviewed and approved by the Institutional Ethics Committee of M. George’s Bethlehem Ayurveda Specialty Hospital & Research Centre, Ernakulam, Kerala, India, with the approval number 2025634/IEC/2025, 5 January 2025.
Informed Consent Statement
Written informed consent was obtained from all participants prior to inclusion in the study. Patients were informed about the purpose of the study, echocardiographic procedures, data usage, and confidentiality protection. All personal identifiers were removed to ensure patient anonymity.
Data Availability Statement
The data are available upon request to the corresponding author subramanianjayakrishnan@gmail.com.
Conflicts of Interest
The authors declare no conflict of interest.
Funding Statement
This research received no external funding.
Footnotes
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.
References
- 1.Beigel R., Wunderlich N.C., Ho S.Y., Arsanjani R., Siegel R.J. The left atrial appendage: Anatomy, function, and noninvasive evaluation. JACC Cardiovasc. Imaging. 2014;7:1251–1265. doi: 10.1016/j.jcmg.2014.08.009. [DOI] [PubMed] [Google Scholar]
- 2.Left Atrial Appendage (LAA) [(accessed on 7 October 2025)]. Available online: https://my.clevelandclinic.org/health/body/left-atrial-appendage.
- 3.Naksuk N., Padmanabhan D., Yogeswaran V., Asirvatham S.J. Left atrial appendage: Embryology, anatomy, physiology, arrhythmia and therapeutic intervention. JACC Clin. Electrophysiol. 2016;2:403–412. doi: 10.1016/j.jacep.2016.06.006. [DOI] [PubMed] [Google Scholar]
- 4.Li Y., Jiang L., Wang L., Yin X., Han Q., Feng Y. Left atrial appendage thrombus in an elderly patient with atrial fibrillation during non-cardiac surgery-a case report. BMC Anesthesiol. 2023;23:335. doi: 10.1186/s12871-023-02286-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Yamamoto M., Seo Y., Kawamatsu N., Sato K., Sugano A., Machino-Ohtsuka T., Kawamura R., Nakajima H., Igarashi M., Sekiguchi Y., et al. Complex left atrial appendage morphology and left atrial appendage thrombus formation in patients with atrial fibrillation. Circ. Cardiovasc. Imaging. 2014;7:337–343. doi: 10.1161/circimaging.113.001317. [DOI] [PubMed] [Google Scholar]
- 6.Presti A.M.L., Monteleone A., Musotto G., Tamburini A., Napoli E., Burriesci G. Modelling of thrombus formation, growth and embolisation in the left atrial appendage under atrial fibrillation. Comput. Biol. Med. 2025;191:110134. doi: 10.1016/j.compbiomed.2025.110134. [DOI] [PubMed] [Google Scholar]
- 7.Cresti A., Camara O. Left atrial thrombus—Are all atria and appendages equal? Card. Electrophysiol. Clin. 2023;15:119–132. doi: 10.1016/j.ccep.2023.01.008. [DOI] [PubMed] [Google Scholar]
- 8.Castellani C., Gao Y., Kim H., Thompson C., Ning J., Lohr N., Welsh A., Berger M. Left atrial appendage structural characteristics predict thrombus formation. J. Cardiovasc. Electrophysiol. 2023;34:1683–1689. doi: 10.1111/jce.15994. [DOI] [PubMed] [Google Scholar]
- 9.Ito T., Suwa M. Left atrial spontaneous echo contrast: Relationship with clinical and echocardiographic parameters. Echo Res. Pract. 2019;6:R65–R73. doi: 10.1530/erp-18-0083. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Hur J., Kim Y.J., Lee H.J., Nam J.E., Ha J.W., Heo J.H., Chang H.J., Kim H.S., Hong Y.J., Kim H.Y., et al. Dual-enhanced cardiac CT for detection of left atrial appendage thrombus in patients with stroke: A prospective comparison study with transesophageal echocardiography. Stroke. 2011;42:2471–2477. doi: 10.1161/STROKEAHA.110.611293. [DOI] [PubMed] [Google Scholar]
- 11.Romero J., Husain S.A., Kelesidis I., Sanz J., Medina H.M., Garcia M.J. Detection of left atrial appendage thrombus by cardiac computed tomography in patients with atrial fibrillation: A meta-analysis. Circ. Cardiovasc. Imaging. 2013;6:185–194. doi: 10.1161/circimaging.112.000153. [DOI] [PubMed] [Google Scholar]
- 12.Dudziñska-Szczerba K., Kułakowski P., Michałowska I., Baran J. Association between left atrial appendage morphology and function and the risk of ischaemic stroke in patients with atrial fibrillation. Arrhythmia Electrophysiol. Rev. 2022;11:e09. doi: 10.15420/aer.2022.08. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Wang H., Mai P., Huo H., Li X., Zhou D., He F., Li Y. A new integrated machine learning model: Application to improve the accuracy of predicting left atrial appendage thrombus in patients with non-valvular atrial fibrillation. Front. Med. 2025;12:1661696. doi: 10.3389/fmed.2025.1661696. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 14.Barbosa L.C., Fan Y., Lee A.P., Moane S., Vilaça J.L., Morais P. Medical Imaging 2025: Ultrasonic Imaging and Tomography. Volume 13412. SPIE; Bellingham, WA, USA: 2025. A comparative study of deep-learning methods for left atrial appendage segmentation in 3D TEE images; pp. 195–201. [Google Scholar]
- 15.Song L., Niu X., Wang B., Xu X., Wan C., Liu F., Tang X., Yan W., Liu L., Song Z., et al. Research on left atrial appendage thrombogenic milieu prediction model in patients with nonvalvular atrial fibrillation based on machine learning algorithm. BMC Cardiovasc. Disord. 2025;26:99. doi: 10.1186/s12872-025-05396-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16.Jain R., Wessly P., Saric M., Richardson K., Garcia-Sayan E., Addetia K., Howard L., Finn T., Quader N. Multimodality Imaging in Evaluating and Guiding Percutaneous Left Atrial Appendage Occlusion. J. Am. Soc. Echocardiogr. 2025;38:1198–1218. doi: 10.1016/j.echo.2025.07.009. [DOI] [PubMed] [Google Scholar]
- 17.Zhang Z., Zhu Y., Zheng G., Jing H., Xiao B., Xiong L. Diagnostic value of transesophageal echocardiography on morphology and function of left atrial appendage in patients with unclosed foramen ovale complicated with atrial fibrillation. BMC Cardiovasc. Disord. 2025;25:300. doi: 10.1186/s12872-025-04651-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Li C., Zhao C., Wu B., Zhu F., Yang C., Xu B. Association between epicardial adipose tissue imaging characteristics and left atrial appendage thrombus in patients with atrial fibrillation. IJC Heart Vasc. 2025;60:101765. doi: 10.1016/j.ijcha.2025.101765. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Xiong W., Cao Q., Jia L., Chen M., Liu T., Zhao Q., Tang Y., Yang B., Li L., Shi S., et al. Machine-learning model for predicting left atrial thrombus in patients with paroxysmal atrial fibrillation. BMC Cardiovasc. Disord. 2025;25:429. doi: 10.1186/s12872-025-04847-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20.Pieszko K., Hiczkiewicz J., Łojewska K., Uziębło-Życzkowska B., Krzesiński P., Gawałko M., Budnik M., Starzyk K., Wożakowska-Kapłon B., Daniłowicz-Szymanowicz L., et al. Artificial intelligence in detecting left atrial appendage thrombus by transthoracic echocardiography and clinical features: The Left Atrial Thrombus on Transoesophageal Echocardiography (LATTEE) registry. Eur. Heart J. 2024;45:32–41. doi: 10.1093/eurheartj/ehad431. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 21.Arsh H., Aqeel I., Ali S., Bangash A., Kumar S., Khan S., Malik J., Akhtar W. Computed Tomography Versus Transesophageal Echocardiography (TEE) in the Detection of Left Atrial Appendage (LAA) Morphology and Determinants of Clot Formation in Atrial Tachycardia. J. Atr. Fibrillation Electrophysiol. 2024;18 [Google Scholar]
- 22.Hajhosseiny R., Ariff B., Cole G., Koa-Wing M., Pabari P., Sutaria N., Qureshi N., Kanagaratnam P., Rana B. Advancements in 3D Transoesophageal Echocardiography (TOE) and Computed Tomography (CT) for Stroke Prevention in Left Atrial Appendage Occlusion Interventions. J. Clin. Med. 2024;13:6899. doi: 10.3390/jcm13226899. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 23.Zhao Y., Cao L.Y., Zhao Y.X., Wang F., Xie L.L., Xing H.Y., Wang Q. Medical record data-enabled machine learning can enhance prediction of left atrial appendage thrombosis in nonvalvular atrial fibrillation. Thromb. Res. 2023;223:174–183. doi: 10.1016/j.thromres.2023.01.001. [DOI] [PubMed] [Google Scholar]
- 24.Alkhouli M., Alarouri H., Kramer A., Korsholm K., Collins J., De Backer O., Hatoum H., Nielsen-Kudsk J.E. Device-related thrombus after left atrial appendage occlusion: Clinical impact, predictors, classification, and management. Cardiovasc. Interv. 2023;16:2695–2707. doi: 10.1016/j.jcin.2023.10.046. [DOI] [PubMed] [Google Scholar]
- 25.Qiao Y., Zhao Z., Cai X., Guo Y., Liu K., Guo J., Guo T., Niu G. Prevalence, predictors and management of left atrial appendage thrombogenic milieu in atrial fibrillation with low thromboembolic risk. Thromb. J. 2023;21:34. doi: 10.1186/s12959-023-00478-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 26.Zeng D., Chang S., Zhang X., Cao X., Zhong Y., Cai Y., Huang T., Wu J. Machine learning model for predicting left atrial thrombus or spontaneous echo contrast in non-valvular atrial fibrillation patients based on multimodal echocardiographic parameters. medRxiv. 2024 doi: 10.1101/2024.04.10.24305639. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Zantvoort K., Nacke B., Görlich D., Hornstein S., Jacobi C., Funk B. Estimation of minimal data sets sizes for machine learning predictions in digital mental health interventions. npj Digit. Med. 2024;7:361. doi: 10.1038/s41746-024-01360-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Abanador-Kamper N., Bepperling J., Seyfarth M., Haage P., Kamper L. Impact of left atrial appendage morphology on thrombus formation in TAVI patients with atrial fibrillation. Eur. J. Med. Res. 2023;28:88. doi: 10.1186/s40001-023-01057-y. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 29.Yaghi S., Chang A., Ignacio G., Scher E., Panda N., Chu A., Wu M., Lord A., Mac Grory B., Furie K., et al. Left atrial appendage morphology improves prediction of stagnant flow and stroke risk in atrial fibrillation. Circ. Arrhythmia Electrophysiol. 2020;13:e008074. doi: 10.1161/circep.119.008074. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Lip G.Y., Nieuwlaat R., Pisters R., Lane D.A., Crijns H.J. Refining clinical risk stratification for predicting stroke and thromboembolism in atrial fibrillation using a novel risk factor-based approach: The euro heart survey on atrial fibrillation. Chest. 2010;137:263–272. doi: 10.1378/chest.09-1584. [DOI] [PubMed] [Google Scholar]
- 31.Authors/Task Force Members. Camm A.J., Lip G.Y., De Caterina R., Savelieva I., Atar D., Hohnloser S.H., Hindricks G., Kirchhof P., ESC Committee for Practice Guidelines (CPG) et al. 2012 focused update of the ESC guidelines for the management of atrial fibrillation: An update of the 2010 ESC guidelines for the management of atrial fibrillation developed with the special contribution of the European Heart Rhythm Association. Eur. Heart J. 2012;33:2719–2747. doi: 10.1093/eurheartj/ehs253. [DOI] [PubMed] [Google Scholar]
- 32.Sánchez A.A.L. Application of scales to determine thromboembolic and hemorrhagic risk in atrial fibrillation. Rehabil. Interdiscip. 2021;1:10. doi: 10.56294/ri202110. [DOI] [Google Scholar]
- 33.Liu R., Li Y. Morphology and function assessment of left atrial appendage in patients with atrial fibrillation. Echocardiography. 2024;41:e70013. doi: 10.1111/echo.70013. [DOI] [PubMed] [Google Scholar]
- 34.Cui J., Xia S.-J., Tang R.-B., He L., Guo X.-Y., Li S.-N., Liu N., Sang C.-H., Long D.-Y., Du X., et al. Morphology and location of thrombus and sludge in patients with non-valvular atrial fibrillation. BMC Cardiovasc. Disord. 2024;24:398. doi: 10.1186/s12872-024-04073-w. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 35.Fang R., Li Y., Zhang Y., Chen Q., Liu Q., Li Z. Impact of left atrial appendage location on risk of thrombus formation in patients with atrial fibrillation. Biomech. Model. Mechanobiol. 2021;20:1431–1443. doi: 10.1007/s10237-021-01454-4. [DOI] [PubMed] [Google Scholar]
- 36.Hautmann M., Zacher M., Fuchs S., Pérez C.M., Ahmidou A., Kerber S., Barth S. Left atrial appendage thrombus formation, potential of resolution and association with prognosis in a large real-world cohort. Sci. Rep. 2023;13:889. doi: 10.1038/s41598-023-27622-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Paolisso P., Foà A., Bergamaschi L., Graziosi M., Rinaldi A., Magnani I., Angeli F., Stefanizzi A., Armillotta M., Sansonetti A., et al. Echocardiographic Markers in the Diagnosis of Cardiac Masses. J. Am. Soc. Echocardiogr. 2023;36:464–473.e2. doi: 10.1016/j.echo.2022.12.022. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
The data are available upon request to the corresponding author subramanianjayakrishnan@gmail.com.








