Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2026 Oct 17.
Published in final edited form as: Proc IEEE Int Symp Biomed Imaging. 2026 May 20;2026:10.1109/isbi61048.2026.11515952. doi: 10.1109/isbi61048.2026.11515952

PARALLEL ROUTE COHERENT MIXUP DEEP LEARNING FOR SINGLE SOURCE TO MULTI-DOMAIN GENERALIZED PROSTATE CANCER SEGMENTATION FOR MR GUIDED ADAPTIVE RADIOTHERAPY

Josiah Simeth 1, Sudharsan Madhavan 1, Andreas Wibmer 1, Daniel Gorovets 1, Sean McBride 1, Himanshu Nagar 1, Victoria Brennan 1, Neelam Tyagi 1, Harini Veeraraghavan 1
PMCID: PMC13670147  NIHMSID: NIHMS2211000  PMID: 42889479

Abstract

Magnetic resonance imaging (MRI) guided adaptive radiotherapy for prostate cancer (PCa) can allow to adapt treatment every day to the geometry of tumor and organs to deliver precise treatments while sparing organs of radiation. However, manual delineation of tumors and organs limits the adoption of this technology. Deep learning (DL) methods, though promising for in-distribution (ID) data that resembles training, deteriorate in performance when applied to out-of-distribution (OOD) datasets. Hence, we developed a novel parallel and coherent feature mixup (PaRC-mix) training approach for single source to multi-domain generalization. PaRC-mix creates feature augmentations at multiple network layers through matching linear combination of features extracted across training batches. PaRC-mix training was implemented in UNet++ to segment PCa from apparent diffusion coefficient images and compared to other mixup approaches. Models were trained on 2,029 samples from 3.0T GE MRI and tested on 557 PCa samples from 3 datasets used for diagnosis, treatment planning, and during radiation scans acquired using 3T Siemens, 3T Philips, and 1.5T Elekta Unity MR-Linac scanners from public and institutional datasets. PaRC-mix training led to significantly more accurate tumor detection (p < 0.001) and segmentation (p < 0.001) compared to other methods.

Index Terms—: Prostate Cancer, Cancer Segmentation, Deep Learning, Domain Generalization, Manifold Mixup

1. INTRODUCTION

Accurate segmentation of prostatic cancers (PCa) from magnetic resonance imaging (MR/MRI) is essential for MRI-guided radiotherapies. Current commercial and clinical solutions have seen great success in segmenting the whole prostate gland, but performance is much worse for PCa. Unlike prostate gland, segmentation of PCa is challenging and prone to inter-rater delineation variability because of poor tumor-tissue differentiation, small lesion sizes (under 2 cm3) as well as variable appearance in the peripheral, central, and transition zone due to complex anatomy of the prostate gland[1], [2], [3]. Hence, consistently accurate localization and delineation of PCa is essential for accurate delivery of biologically effective dose for safer and effective adaptive radiation treatments. Even when models are capable of segmenting PCa, the generalizability of these models to other institutions and datasets, particularly to clinical datasets like MR-simulation scans for planning and MR-Linac scans for treatment, is dubious. This is the problem of out of distribution data (OOD).

Multi-source domain adaptation mitigates accuracy degradation on OOD datasets by including multi-institution datasets into training, which is not practical for most applications due to limitations in transferring patient datasets from patient privacy concerns, as well as difficulty of obtaining manually delineated datasets from various institutions[3]. Another set of approaches employ generative adversarial networks (GAN) to synthesize different domain datasets and increase data diversity[4], [5], [6], [7]. Whereas the latter approach alleviates the need for labeled multi-domain datasets, it still requires unlabeled multi-institutional datasets for GAN training. Models trained on a single source and then refined through few-shot fine tuning have shown to be effective for prostate gland segmentation from ultrasound images. Alternatively, domain invariant features as organ shapes have shown to be effective to achieve multi-domain generalization. Whereas geometry is a useful feature for organs, cancerous lesions that depict considerable appearance and shape changes even in same patient undergoing treatment are less effective as a feature to inform segmentation.

A clinically practical approach is to train on a single source and with direct applicability to multi-target domain datasets by training models to extract domain invariant image features18. This approach can also be combined with other approaches to enhance the benefits of training when multiple domain datasets are available. A manifold feature mixup strategy was implemented into UNet++[8] to simultaneously regularize features extracted at different image resolutions across training batches and reduce feature variability to image differences.

2. METHODS

Feature mixup augmentation for training deep networks: The coherent mixup strategy used in PaRC-mix performs a non-linear mixup by sequentially varying features at all the feature layers occurring in the backbone as well as intermediate layers from deep skip and dense feature streams to produce a rich representation of the computed features. Hence, this approach allows extraction of a more comprehensive variation of the data at various feature resolutions and semantic context levels. Coherent feature mixup at any layer k in the network will involve a set of features from residual and skip layers that input to that feature layer Xk=(xk1,xk2,…xkn) along with the corresponding labels y. For example, in Figure 1, the features at a given layer are defined by the feature streams (lines and arrows) that intersect with the mixup block (green box) defining mixup at that layer. To execute coherent mixup we combine features and labels from two intermediate minibatches (Xk,yk) and (Xk’,yk’):

Xmixed=X*λ+X’*(1-λ)
ymixed=y*λ+y’*(1-λ)

Figure 1.

Figure 1.

The architecture for UNet++ with PaRC-mix. PaRC-mix can include any combination of layers for mixup. For each feature stream rsk passing through a mixup layer the features in each sample of the batch are interpolated using the weighting parameter (drawn from the beta distribution ꞵ(ɑ, ɑ)), with another random sample from the batch is held constant for all concurrent interpolations for each feature stream and the targets for each sample (yi). Dense skip connections are not depicted here to improve readability.

Incoherent mixup operates only on a subset of the feature streams, most often the layers occurring in the network backbone, e.g., Xk_backbone=(xkk). This results in incoherence between the omitted features and the rest of the network, including the target labels.

In our implementation we create the minibatch (X’k,y’k) by randomly shuffling the rows of the batch (Xk,yk), resulting in a random pairing of the samples in the superbatch. Our mixup approach allows a flexible mixup strategy spanning multiple feature layers, creating a non-linear mixup of more than a single pair of batch elements

2.1. Implementation

The method was applied to a standard UNet++ architecture [8] as shown in Figure 1. The model had a depth of five nodes, corresponding to four UNet++ subnetworks. Mixup training does not alter the network architecture, and, following training, the default network was used for testing.

We investigate 4 different training methods which differ from each other only in mixup strategy: (1) No-mixup, wherein the network is trained with only standard augmentations such as image rotations, scaling, color jittering, etc. (2) Input-mix, wherein the input images and labels to the network are subject to mixup using the inputs from different training batches. (3) Incoherent-mix, which incorporates feature mixup along the feature layers occurring in the network backbone, and (4) PaRC-mix, which incorporates coherent feature mixup along all parallel paths or features layers in the network.

Models were implemented in Pytorch[9]. Networks were trained with Adam using a learning rate of 0.0001. Models were initially trained with a fixed learning rate for 20 epochs, followed by a linearly decaying learning rate until a maximum of 600 epochs. The label smoothing hyperparameter ϵ, batch size, and mixup hyperparameters were determined empirically by best segmentation performance defined as the model with the highest normed score on the validation dataset. Label smoothing was applied with ϵ=0.001. Batch size was set to eight. Mixup weight defined using the distribution (1,1), which corresponds to a uniform distribution.

2.2. Patient characteristics and datasets

Patients with PCa from 4 different datasets (see Table 1) were analyzed and consisted of: (a) Training, institutional ID dataset of patients who underwent diagnostic imaging using 3 Tesla GE with endorectal coil followed by surgical resection[10], [11], (b) ProstateX, an open source OOD dataset[12], [13] acquired on 3 Tesla Siemens diagnostic scanners with manual PCa delineations[14], (c) MR-Sim, internal OOD dataset of patients with PCa acquired on 3 Tesla Philips MR scanners for simulating radiation treatment plans prior to MR guided RT, and (d) MR-Linac, internal OOD dataset of patients with prostate cancer who underwent hypofractionated adaptive RT on 1.5 Tesla Philips MR-Unity (Elekta) with onboard imager and Linac system, with images acquired daily prior to treatment. Internal data was collected in accordance with a protocol approved by the MSKCC institutional review board. ProstateX data was used retrospectively as provided in The Cancer Imaging Archive.

Table 1.

Number of intermediate to high risk (IHR) lesions for each dataset (counting lesions contained in separate scans multiple times), and the corresponding lesion characteristics in terms of volume and ADC.

Dataset Scanner Number of IHR or PIRADS>3 Lesions
(GS ≥ 7) /Total
Median Lesion Volume (cc) Median Lesion ADC (×10-3 mm2/s) Resolution
(mm3)

Training/ Validation Internal diagnostic w/ EC, 3T GE 147/191 0.84 [0.39–1.3] 0.95 [0.87–1.11] 0.625×0.625×3 and 0.78×0.78×3.6
ProstateX External diagnostic, 3T Siemens 76/298 1.1 [0.51–2.6] 0.96 [0.88–1.04] 2×2×3 and 2×2×4
MR-Sim Internal, planning, 3T Philips 59/59 0.58 [0.26–1.8] 0.81 [0.69–0.94]* 1.125×1.125×4
MR- Linac Internal, treatment, 1.5T Philips 200/200 1.52 [0.99–2.4]* 1.43 [1.28–1.53]* 1.92×1.92×4

Note that the images in the training and validation set used an endorectal coil (EC). Significant differences in lesion volume or ADC from the training set are marked with an *.

3. RESULTS

Example segmentations for each dataset and model can be seen in Figure 2. PaRC-mix had the highest generalization accuracy, outperforming other methods for both DSC and HD95. Table 2 contains the median DSC for each dataset and method, along with the relative recall and precision for each approach. As a general trend PaRC-mix and incoherent-mix improved precision (fewest false detections) over no-mix or input-mix, while PaRC-mix and input-mix improved recall (more lesions detected) and lesion DSC over no-mix and incoherent-mix.

Figure 2.

Figure 2.

Representative examples from analyzed MR scanners used in the testing datasets showing segmentation results produced by various training strategies. Manual delineation is depicted using solid “white” contour while model-generated segmentation is shown in dotted “cyan” color. The two columns of MR-Sim and MR-Linac show matching patients from MR-Sim and the first fraction of treatment on the MR-Linac.

Table 2.

(left) The median Dice scores comparing all lesions of GS ≥ 7 detected by at least one model.

(A) ProstateX,
3T Siemens
MR-Sim,
3T Philips
MR-Linac,
1.5T Philips
All

Dice Score
(diff)
Dice Score
(diff)
Dice Score
(diff)
Dice Score
(diff)

No-mixup
0.55 (↓0.09**) 0.42 (↓0.04*) 0.30 (↓0.04**) 0.34(↓0.07***)
Input-mix
0.59 (↓0.05) 0.44 (↓0.02) 0.30 (↓0.04**) 0.39 (↓0.02***)
Incoherent-mix
0.63 ↓0.01) 0.35 (↓0.11) 0.30 (↓0.04***) 0.37 (↓0.04***)
PaRC-mix 0.64 0.46 0.34 0.41

(B) ProstateX,
3T Siemens
MR-Sim,
3T Philips
MR-Linac,
1.5T Philips
All

Precision Precision Precision Precision

No-mixup
0.21* 0.18 0.16 0.18*
Input-mix
0.24 0.18 0.14 0.19
Incoherent-mix
0.29 0.20 0.17 0.22
PaRC-mix 0.27 0.21 0.17 0.21
(C) ProstateX,
3T Siemens
MR-Sim,
3T Philips
MR-Linac,
1.5T Philips
All

Recall Recall Recall Recall

No-mixup
0.87* 0.69 0.78 0.86
Input-mix
0.96 0.75 0.69** 0.85**
Incoherent-mix
0.99 0.68 0.72 0.85**
PaRC-mix 1 0.8 0.78 0.91

Models under-performing PaRC-mix are indicated with blue down arrow and those over-performing PaRC-mix are indicated by red up arrow. (B) shows precision and (C) shows recall metrics for each model and dataset. Models with significantly different scores compared to PaRC-mix are indicated by * for p < 0.05, ** for p < 0.01, *** for p < 0.001.

3.1. Disaggregated analysis of models’ segmentation accuracies with varying lesion characteristics

Lesion level GS were available for ProstateX; 35 lesions had GS 4+ 3 or higher, 41 had GS 3+4, and 36 had GS 3+3. Disaggregated analysis found both PaRC-mix and incoherent-mix training achieved higher median accuracy than no-mixup or input-mix.

Lesion level zone designations were available for a subset of ProstateX, MR-Sim, and MR-Linac datasets . 38 lesions were designated in the peripheral zone (PZ) and 97 lesions in the transition zone (TZ). Lesions occurring in the anterior stroma were grouped with the TZ lesions.

Performance enhancement was most pronounced for the most difficult lesions. Lesions in the TZ were segmented with significantly higher accuracy compared to those occurring in the PZ [1], [15]irrespective of the training approach (no-mixup p<0.001, input-mix p=0.006, incoherent-mix p<0.001, PaRC-mix p = 0.003). Performance gap analysis comparing normed scores for lesions occurring in TZ and PZ showed the largest gap for no-mixup training (0.23) The performance gap decreased to 0.11 for input-mix, 0.16 for incoherent-mix, and 0.14 for PaRC-mix (which had the highest median DSC in both categories).

When assessed in terms of Gleason score the least aggressive lesions tended to be the hardest to segment. Performance gap was computed as the difference in the median normed score between intermediate or highly aggressive (GS 3+4 or higher) and less aggressive (GS 3+3) lesions for the individual methods. Models trained with no-mixup and input-mix resulted in the largest DSC performance gaps (0.059 and 0.071), indicating that these models were not as robust to variations in lesion aggressiveness. Mixup improved segmentations scores and feature mixup training reduced the performance gap, with a performance gap of 0.035 for incoherent-mix, and 0.006 for PaRC-mix.

These results indicate that mixup training, especially the feature mixup methods like PaRC-mix and incoherent mix improved the robustness of the models to variations in lesion aggressiveness or spatial location within the prostate gland.

3.2. Fine-tuning further enhanced accuracy for clinical cases on the MR-Linac dataset

Finetuning of the PaRC-mix model via a 5-fold cross validated division of the 40 MR-Linac patients resulted in a significant increase in DSC from 0.33 (0.18–0.43) to 0.38 (0.18–0.55), p<0.001, and decrease in HD95 from 7.76 mm (5.73 mm −11.84 mm) to 6.41 mm (4.75 mm - 9.82 mm), p<0.01. This was accompanied by a statistically significant drop in false positives, with precision increasing from 0.17 to 0.25 (p<0.001), but recall did not change significantly (0.78 vs 0.81, p = 0.36).

4. DISCUSSION

To our knowledge, this is the first PCa lesion segmentation approach that evaluated the generalization capability of a single source training method across a reasonably wide range of scanners and for patients scanned at different stages of disease and treatment, including diagnosis, planning simulation, and during hypofractionated radiation treatment. Importantly, our work also studied why generalization occurs with different training approaches. Prior works typically used data acquired from a single institution[1], [15]. A few prior works used data from different institutions for evaluation but were acquired with the same scanner manufacturer[16], [17], [18]. In our prior work, we evaluated UNet++ and multiple other methods on ProstateX and a subset of the MR-Sim scans[10]. In general, prior works, including ours, studied the capability of the models applied to diagnostic quality MRI as opposed to images acquired for treatment simulation and across the course of radiation treatment. Of note, prior works typically focused on segmenting the whole prostate gland, easier to segment than the intra-prostatic lesions due to the inherent difficulty in detecting the lesions and ensuing variability even between clinicians in delineating such lesions[1], [2], [3]. Furthermore, segmenting whole prostate gland is insufficient for dose escalation therapies that boost the dose to the dominant lesions, shown to be effective in reducing biological recurrence and increasing overall survival by clinical trials such as the multi-institutional FLAME trial.[19], [20]

Prior methods for domain invariant segmentation often used geometric priors, which are applicable to organs but not tumors due to their highly variable appearance and shapes. Adversarial perturbation of image intensities[21] and image style to alter underlying first and second order texture statistics[22] can increase data diversity. However, such methods only vary the intensity statistics of the images themselves, which may not lead to sufficient diversity in the extracted features. Alternative methods such as feature-level augmentation implemented by linearly mixing input features from different domains[23] build on the input mixup methods[24]. Previously, Jung et al[25] demonstrated enhanced accuracy by implementing feature level mixup separately for input, encoder, decoder, bottleneck and skip level layers of a UNet. However, this approach did not implement any measures to ensure coherence between manifold mixup in the network backbone and the long skip connections. Other feature-level mixup approaches employed feature mixup at each skip connection and output of the bottleneck layer[26] or randomly manipulated the feature layers used for mixup augmentation[27] implemented into the UNet in the context of semi-supervised learning. PaRC-mix improves over prior methods by performing feature level mixup coherently into encoder, decoder, residual and skip features within a single network. Our results show that PaRC-mix that uses coherent mixup of features for all paths results in better generalization compared to the incoherent mixup approach when considering both networks.

There was a drop in performance when the models were directly applied to the MR-Linac datasets, possibly due to factors beyond image distribution shift such as differing norms for delineating lesions for radiation treatments relative to diagnosis by radiologists. We found that these segmentations can be improved by fine-tuning for radiation treatments. Further improvements could be achieved with patient-specific fine-tuning as needed to achieve highly accurate segmentation in consequent treatment fractions, reducing delineation requirements for radiation oncologists. This work focused on assessing the geometric accuracy of the AI generated segmentations compared to clinical delineations, but not in assessing if the AI segmentations further reduced clinical variability. Proper and detailed assessment of the same requires a larger and focused study and is planned future work. Our model was limited to using only the ADC instead of combining T2-weighted MRI to reduce impact of potential variations from T2-weighted imaging and limited accuracy improvement for combining the two modalities seen in our preliminary evaluation. Nevertheless, our results show reliable performance on multiple analyzed datasets with varied imaging acquisitions.

5. CONCLUSIONS

PaRCmix significantly improved the segmentation generalization to scanners and acquisitions outside the training distribution.

Fig. 3.

Fig. 3.

Disaggregated analysis depicts the DSC for the analyzed methods with respect to Gleason scores and lesion location categorized as peripheral zone or PZ and transition zone or TZ.

13. ACKNOWLEDGMENTS

This work is supported in part by NIH grant P30 CA008748. The authors thank the MSKCC im-aging and radiation sciences (IMRAS) seed grant.

14. REFERENCES

  • [1].Chen MY, Woodruff MA, Dasgupta P, and Rukin NJ, “Variability in accuracy of prostate cancer segmentation among radiologists, urologists, and scientists,” Cancer Med, vol. 9, no. 19, pp. 7172–7182, Aug. 2020, doi: 10.1002/cam4.3386. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [2].Liechti MR et al. , “Manual prostate cancer segmentation in MRI: interreader agreement and volumetric correlation with transperineal template core needle biopsy,” Eur Radiol, vol. 30, no. 9, pp. 4806–4815, Sep. 2020, doi: 10.1007/s00330-020-06786-w. [DOI] [PubMed] [Google Scholar]
  • [3].Dai Z et al. , “Segmentation of the Prostatic Gland and the Intraprostatic Lesions on Multiparametic Magnetic Resonance Imaging Using Mask Region-Based Convolutional Neural Networks,” Adv Radiat Oncol, vol. 5, no. 3, pp. 473–481, Feb. 2020, doi: 10.1016/j.adro.2020.01.005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [4].Zhu Q, Du B, and Yan P, “Boundary-Weighted Domain Adaptive Neural Network for Prostate MR Image Segmentation,” IEEE Trans Med Imaging, vol. 39, no. 3, pp. 753–763, Mar. 2020, doi: 10.1109/TMI.2019.2935018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [5].Jiang J and Veeraraghavan H, “Unified cross-modality feature disentangler for unsupervised multi-domain MRI abdomen organs segmentation,” Med Image Comput Comput Assist Interv, vol. 12262, pp. 347–358, Oct. 2020, doi: 10.1007/978-3-030-59713-9_34. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [6].Jiang J et al. , “Tumor-aware, Adversarial Domain Adaptation from CT to MRI for Lung Cancer Segmentation,” Med Image Comput Comput Assist Interv, vol. 11071, pp. 777–785, Sep. 2018, doi: 10.1007/978-3-030-00934-2_86. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [7].“Unsupervised Domain Adaptation with Semantic Consistency Across Heterogeneous Modalities for MRI Prostate Lesion Segmentation | Domain Adaptation and Representation Transfer, and Affordable Healthcare and AI for Resource Diverse Global Health.” Accessed: Sep. 30, 2024. [Online]. Available: https://dl.acm.org/doi/abs/10.1007/978-3-030-87722-4_9 [Google Scholar]
  • [8].Zhou Z, Rahman Siddiquee MM, Tajbakhsh N, and Liang J, “UNet++: A Nested U-Net Architecture for Medical Image Segmentation,” in Deep Learning in Medical Image Analysis and Multimodal Learning for Clinical Decision Support, Stoyanov D, Taylor Z, Carneiro G, Syeda-Mahmood T, Martel A, Maier-Hein L, Tavares JMRS, Bradley A, Papa JP, Belagiannis V, Nascimento JC, Lu Z, Conjeti S, Moradi M, Greenspan H, and Madabhushi A, Eds., Cham: Springer International Publishing, 2018, pp. 3–11. doi: 10.1007/978-3-030-00889-5_1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [9].Paszke A et al. , “PyTorch: An Imperative Style, High-Performance Deep Learning Library,” in Advances in Neural Information Processing Systems, Curran Associates, Inc., 2019. Accessed: Jul. 19, 2022. [Online]. Available: https://proceedings.neurips.cc/paper/2019/hash/bdbca288fee7f92f2bfa9f7012727740-Abstract.html [Google Scholar]
  • [10].Simeth J et al. , “Deep learning-based dominant index lesion segmentation for MR-guided radiation therapy of prostate cancer,” Medical Physics, vol. 50, no. 8, pp. 4854–4870, 2023, doi: 10.1002/mp.16320. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [11].Fehr D et al. , “Automatic classification of prostate cancer Gleason scores from multiparametric magnetic resonance images,” PNAS, vol. 112, no. 46, pp. E6265–E6273, Nov. 2015, doi: 10.1073/pnas.1505935112. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [12].Armato SG et al. , “PROSTATEx Challenges for computerized classification of prostate lesions from multiparametric magnetic resonance images,” J Med Imaging (Bellingham), vol. 5, no. 4, p. 044501, Oct. 2018, doi: 10.1117/1.JMI.5.4.044501. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [13].Litjens G, Debats O, Barentsz J, Karssemeijer N, and Huisman H, “SPIE-AAPM PROSTATEx Challenge Data.” The Cancer Imaging Archive, 2017. doi: 10.7937/K9TCIA.2017.MURS5CL. [DOI] [Google Scholar]
  • [14].Cuocolo R, Stanzione A, Castaldo A, De Lucia DR, and Imbriaco M, “Quality control and whole-gland, zonal and lesion annotations for the PROSTATEx challenge public dataset,” European Journal of Radiology, vol. 138, p. 109647, May 2021, doi: 10.1016/j.ejrad.2021.109647. [DOI] [PubMed] [Google Scholar]
  • [15].Eidex ZA et al. , “MRI-based prostate and dominant lesion segmentation using cascaded scoring convolutional neural network,” Medical Physics, vol. 49, no. 8, pp. 5216–5224, 2022, doi: 10.1002/mp.15687. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • [16].Saha A, Hosseinzadeh M, and Huisman H, “End-to-end Prostate Cancer Detection in bpMRI via 3D CNNs: Effects of Attention Mechanisms, Clinical Priori and Decoupled False Positive Reduction,” Medical Image Analysis, vol. 73, p. 102155, Oct. 2021, doi: 10.1016/j.media.2021.102155. [DOI] [PubMed] [Google Scholar]
  • [17].Kohl S et al. , “Adversarial Networks for the Detection of Aggressive Prostate Cancer,” in Conference paper at MICCAI 2017 arXiv:1702.08014 [cs], MICCAI; 2017. Accessed: Nov. 08, 2021. [Online]. Available: http://arxiv.org/abs/1702.08014 [Google Scholar]
  • [18].Duran A, Dussert G, Rouvière O, Jaouen T, Jodoin P-M, and Lartizien C, “ProstAttention-Net: A deep attention model for prostate cancer segmentation by aggressiveness in MRI scans,” Medical Image Analysis, vol. 77, p. 102347, Apr. 2022, doi: 10.1016/j.media.2021.102347. [DOI] [PubMed] [Google Scholar]
  • [19].Cock LD et al. , “From once-weekly to semi-weekly whole prostate gland stereotactic radiotherapy with focal boosting: Primary endpoint analysis of the multicenter phase II hypo-FLAME 2.0 trial,” Radiotherapy and Oncology, vol. 185, Aug. 2023, doi: 10.1016/j.radonc.2023.109713. [DOI] [PubMed] [Google Scholar]
  • [20].Kerkmeijer LGW et al. , “Focal Boost to the Intraprostatic Tumor in External Beam Radiotherapy for Patients With Localized Prostate Cancer: Results From the FLAME Randomized Phase III Trial,” J Clin Oncol, vol. 39, no. 7, pp. 787–796, Mar. 2021, doi: 10.1200/JCO.20.02873. [DOI] [PubMed] [Google Scholar]
  • [21].Volpi R, Namkoong H, Sener O, Duchi J, Murino V, and Savarese S, “Generalizing to unseen domains via adversarial data augmentation,” in Proceedings of the 32nd International Conference on Neural Information Processing Systems, in NIPS’18. Red Hook, NY, USA: Curran Associates Inc., Dec. 2018, pp. 5339–5349. [Google Scholar]
  • [22].“Realistic Adversarial Data Augmentation for MR Image Segmentation | SpringerLink.” Accessed: Feb. 14, 2025. [Online]. Available: https://link.springer.com/chapter/10.1007/978-3-030-59710-8_65 [Google Scholar]
  • [23].Zhou K, Yang Y, Qiao Y, and Xiang T, “Domain Generalization with MixStyle,” Apr. 05, 2021, arXiv: arXiv:2104.02008. doi: 10.48550/arXiv.2104.02008. [DOI] [Google Scholar]
  • [24].Verma V et al. , “Manifold Mixup: Better Representations by Interpolating Hidden States,” in Proceedings of the 36th International Conference on Machine Learning, JMLR, 2019. Accessed: Sep. 30, 2024. [Online]. Available: https://research.aalto.fi/en/publications/manifold-mixup-better-representations-by-interpolating-hidden-sta [Google Scholar]
  • [25].Jung W, Park S, Jung K-H, and Hwang SI, “Prostate Cancer Segmentation using Manifold Mixup U-Net,” presented at the International Conference on Medical Imaging with Deep Learning -- Extended Abstract Track, Apr. 2019. Accessed: Nov. 08, 2021. [Online]. Available: https://openreview.net/forum?id=r1l80Lw45E [Google Scholar]
  • [26].Zhu J, Shi L, Yan J, and Zha H, “AutoMix: Mixup Networks for Sample Interpolation via Cooperative Barycenter Learning,” in Computer Vision – ECCV 2020, Vedaldi A, Bischof H, Brox T, and Frahm J-M, Eds., Cham: Springer International Publishing, 2020, pp. 633–649. doi: 10.1007/978-3-030-58607-2_37. [DOI] [Google Scholar]
  • [27].Bdair T, Wiestler B, Navab N, and Albarqouni S, “ROAM: Random layer mixup for semi-supervised learning in medical images,” IET Image Processing, vol. 16, no. 10, pp. 2593–2608, 2022, doi: 10.1049/ipr2.12511. [DOI] [Google Scholar]

RESOURCES