Abstract
Aims
Artificial intelligence, particularly deep learning (DL), has shown significant potential for enhancing the assessment of echocardiograms in clinical practice. This systematic review and meta-analysis aimed to evaluate the performance of DL models and to identify factors affecting their performance.
Methods and results
A systematic review of the PubMed, CENTRAL, and Web of Science databases was conducted, yielding 16 248 potential publications. Of these, 160 studies met the inclusion criteria. Only studies applying fully automated DL networks to echocardiographic loops were considered. Performance estimates were pooled using a random-effects meta-analysis. The studies were categorized into five distinct groups: prediction of disease or mortality, replication of established measures, segmentation of cardiac chambers, classification of chamber views, and assessment of image quality. High heterogeneity that could not be resolved was observed in studies focusing on cardiac chamber segmentation and classification. Model performance was influenced by a variety of different factors, including medical target and input characteristics such as video resolution, number of frames used, and total participants included during training.
Conclusion
DL models achieve high performance across various applications in echocardiography. In selected tasks, they may reduce reliance on expert input and support greater automation of echocardiographic workflows. However, further validation, assessment of clinical utility, and evaluation in real-world settings are required before widespread clinical adoption.
Keywords: Echocardiography, Artificial intelligence, Deep learning, Meta-analysis
Graphical Abstract
Graphical Abstract.

Introduction
Echocardiography is a widely accessible, cost-effective, and non-invasive imaging technique that plays a pivotal role in assessing cardiac health.1 It is routinely available in most clinical practices and offers real-time visualization of cardiac structure and function, making it indispensable in the diagnosis and management of numerous cardiovascular conditions.2–4 Despite its extensive utility, the full diagnostic potential of echocardiography may remain untapped: while certain complex patterns and features might elude human interpretation, deep learning (DL) models are able to analyse these patterns5, representing an opportunity for advanced computational techniques to enhance its clinical value.6,7
In recent years, DL models have demonstrated remarkable capabilities in analysing echocardiographic videos, detecting patterns, and deriving measurements that traditionally required human expertise.8 Furthermore, by leveraging the rich data embedded in ultrasound videos, these models can also extract novel metrics of cardiac health imperceptible to the human eye.9 This ability positions DL models as potential tools for providing rapid, standardized assessments of echocardiographic studies.10 Moreover, they hold transformative potential for advancing the utility of this technique by enabling the discovery of new insights into patient health while enhancing diagnostic precision.11
In order to determine the potential of DL models as fully automated tools that expedite tasks traditionally done by physicians, a systematic literature review was conducted on the use of DL to assess cardiac health through the use of echocardiography alongside a meta-analysis of all comparable applications. Although numerous primary studies have reported promising results, the existing literature remains highly heterogeneous with respect to datasets, validation strategies, reported performance metrics, and even the types of tasks being assessed with DL. This heterogeneity makes it difficult to objectively interpret reproducibility and generalizability across clinical settings.
To date, published works have not performed a quantitative synthesis of performance of DL models on the same task across studies. A meta-analysis is therefore warranted to provide pooled performance estimates, assess between-study variability, and explore factors that may affect performance. Importantly, from a clinical perspective, individual high-performing models do not necessarily translate into reliable, scalable tools for real-world implementation. Quantitative synthesis therefore allows for a more rigorous evaluation of whether reported performance is consistent enough to support broader clinical adoption.
To our knowledge, no systematic review on DL in echocardiography, emphasizing what factors affect their performance, has yet been conducted. By pooling comparable outcomes, this study aims to provide a more objective and clinically meaningful assessment of the current maturity of fully automated DL-based echocardiographic tools, and to identify gaps where DL could feasibly be applied.
Methods
Systematic literature search
A systematic search was conducted using the online databases ‘PubMed’ (https://pubmed.ncbi.nlm.nih.gov/), ‘Cochrane Central Register of Controlled Trials’ (CENTRAL, https://www.cochranelibrary.com/central), and Web of Science (https://www.webofscience.com/). The search was limited to studies published after 2014 up to June 9th of 2026 to capture only novel works on DL. The search query used can be found in the Supplementary material online, Appendix I, Methods.
Study selection
Eligibility criteria were developed collaboratively with a team of epidemiologists, cardiologists, and DL experts. Articles were considered eligible if they employed DL methods to analyse echocardiographic video data in a fully automated pipeline, defined as execution without manual pre-processing, user-guided feature selection, or expert interpretation at inference time. Given the large volume of DL research in echocardiography, inclusion was further restricted to studies in which the DL application could reasonably be considered a physician assistance tool, meaning that the outputs of the model directly supported clinical interpretation or decision making rather than image formation. Accordingly, studies focused exclusively on image enhancement or reconstruction tasks, such as denoising, dehazing, super-resolution, or image reconstruction, were excluded.
Articles were excluded if they met any of the following criteria: irrelevant content, no DL methods applied, absence of echocardiography videos as input, use of proprietary software, no reported performance against a ground-truth reference, or publication as a review, case report, letter, or other non-original research article. Studies relying on manual input prior to application of the DL model were excluded, including manual selection of video frames, manual extraction of still images from videos, reported manual view selection, manual region-of-interest selection used as model input, or any other expert-driven processing required prior to model application. Studies combining automated DL analysis with manual pre-processing were therefore not considered fully automated and were excluded. Manual annotations used solely for generation of ground-truth labels (e.g. expert defined regions-of-interest or segmentation) or training of the DL models were permitted. Studies analysing specific echocardiographic views were included provided that manual view assignment prior to model application was not explicitly reported. When the method of view assignment was not described, studies were retained to avoid excluding potentially fully automated approaches. Transoesophageal, intracardiac, foetal, paediatric, and animal echocardiography studies were excluded. Point-of-care ultrasound and stress echocardiography studies were eligible for inclusion.
Eligible studies were required to operate directly on echocardiogram videos or automatically extracted video-derived frames and to report a clearly defined analytical task. Tasks of interest included the automation of functions traditionally performed by experts, specifically: (i) segmentation of cardiac chambers; (ii) estimation or prediction of established quantitative echocardiographic measurements; (iii) cardiac chamber view classification; and (iv) assessment of image quality. In addition, studies applying DL models to diagnose disease or to predict clinical outcomes, including mortality, from echocardiographic data were included.
Titles and abstracts of all identified articles were screened for eligibility by two researchers (A.R.M. and S.Z.) using the online tool EPPI Reviewer (https://eppi.ioe.ac.uk/EPPIReviewer-Web/). Any uncertainties regarding an article’s eligibility were resolved in a structured consultation process with two additional reviewers—specialists in cardiology (S.-O.T. and P.S.W.). Full-text articles were assessed only if the title or abstract suggested relevance to the research topic. Reasons for considering studies ineligible for inclusion were recorded for both abstract and full article screening. Risk of bias was assessed using a modified version of the Risk of Bias Assessment Tool for non-randomized Studies.12 Details are available in Supplementary material online, Appendix I.
Data extraction
Results reported in this review were based on testing with external datasets whenever possible. If external testing was not done, results from the held-out data were recorded instead. In cases where comparable results from the same study were reported for held-out datasets but not for external datasets, the held-out testing results were included. Collected data were aggregated by DL goals (prediction of death or disease, established measure replication, segmentation, cardiac view classification, and quality assessment) to facilitate further analysis. The type of data extracted from all articles is available in the Supplementary material online, Appendix I.
Statistical analysis
Sample sizes reported in the text refer explicitly to the number of individuals included in each study. In order to ensure consistent weighting across studies, those without information on the number of individuals in the testing set were excluded from the meta-analysis. Variance was calculated only for proportion-based metrics, using the reported performance estimate and the corresponding testing sample size. Proportions were transformed using the double-arcsine (Freeman-Tukey) method prior to meta-analysis to stabilize the variances of results reported in proportions. To ensure methodological consistency, meta-analyses were conducted separately for each performance metric, with studies pooled only when reporting the same measure (e.g. accuracy, area under the curve (AUC), Dice coefficient, mean absolute error, etc.) for comparable clinical tasks or outcomes. For non-proportion metrics for which standard errors, confidence intervals, or sufficient information to derive valid variance estimates were unavailable, inverse-variance pooling was not performed; these outcomes were summarized descriptively or analysed using the sample-weighted approaches specified in Supplementary material online, Appendix I. Different metric types were not combined unless a statistically valid transformation enabled direct comparison. Information on specific transformations used to create comparable metrics can be found in the Supplementary material online, Appendix I.
Variance due to heterogeneity between studies was reported using the I2 statistic. Multilevel regression analyses were performed to address dependent data, in the case of this review, this occurred when a single study had multiple targets for their DL model, all with different effect sizes. In cases of residual heterogeneity, meta-regression analyses were performed if at least five studies reported relevant variables to test for moderation of results by characteristics describing the base architecture of the model, the size of the sample used for model training, the specific subgroup target, or any characteristic referring to the shape and size of the input. If sample size was not sufficient for analysis, moderators were applied independently. Cardiac chamber classification studies did not apply multilevel analysis due to independence of included works. Sensitivity analyses and outlier assessments were done using Cook’s distance (Cook’s D)13 to determine the undue influence of individual observations on model outcomes. Small-study effects were evaluated using funnel plots.14
Meta-analyses and meta-regression models were implemented using the R package metafor.15 A two-sided P-value below 0.05 was considered statistically significant. All statistical analyses were performed using the R statistical programming environment version 4.2.1. (https://www.r-project.org/).
Results
Study inclusion
A total of 16 248 studies were identified through abstract screening. After removing duplicates (n = 7903), 7710 articles were excluded based on title and abstract for not meeting inclusion criteria. A total of 635 full-text articles were assessed for eligibility. Ultimately, 160 articles, all of which can be found in the Supplementary material online, Appendix I, were included in the final systematic review and meta-analysis (see Figure 1). Independent screening of a random sample of 103 abstracts by the two reviewers demonstrated 92.2% agreement (Cohen’s κ = 0.78, P < 0.001). The summarized characteristics of all included studies are presented in Supplementary material online, Table S1. Counts for DL model architectures stratified by task are presented in Table 1. U-Net was the most commonly used architecture for segmentation, whereas ResNet and three-dimensional convolutional neural networks (3D CNNs) were most frequently employed for disease or mortality prediction and the replication of established echocardiographic measurements. Clinical targets assessed within the three major task categories (disease or mortality prediction, replication of established measurements, and segmentation) are summarized in Table 2. Valvular heart diseases were the most frequently investigated target in prediction studies, while systolic function was the most commonly assessed target in studies aiming to replicate established echocardiographic measurements, most often being left ventricular ejection fraction (LVEF). Risk of bias assessments are provided in Supplementary material online, Figure S1, which show that studies from 2024 onward were less likely to be rated as having high risk of bias compared with earlier publications. A timeline depicting the use of each architecture from 2018 to 2026, along with key DL advancements during this period, is presented in Figure 2.16–25
Figure 1.

Flowchart for study selection following PRISMA guidelines. DL, deep learning; PRISMA, preferred reporting items for systematic reviews and meta-analyses. The flowchart depicts the flow of information throughout each step of the systematic review.
Table 1.
Included studies aggregated by deep learning method used in each of the five tasks
| Total counts (N = 161) |
Disease/mortality prediction (N = 59) | Measurement replication (N = 59) | Segmentation (N = 59) |
Classification of views (N = 22) | Quality assessment (N = 10) | |
|---|---|---|---|---|---|---|
| U-Net and variations | 23.6 (38) | 3.39 (2) | 13.6 (8) | 47.5 (28) | N/A | N/A |
| ResNet and variations | 20.5 (33) | 20.3 (12) | 18.6 (11) | 8.47 (5) | 13.6 (3) | 20.0 (2) |
| 3D CNN | 16.1 (26) | 16.9 (10) | 16.9 (10) | 5.08 (3) | 13.6 (3) | N/A |
| R2 + 1D | 13.0 (21) | 18.6 (11) | 5.08 (3) | 1.69 (1) | 18.2 (4) | 20.0 (2) |
| 2D CNN | 7.45 (12) | 5.08 (3) | 5.08 (3) | 3.39 (2) | 13.6 (3) | 10.0 (1) |
| DeepLabV3 | 6.83 (11) | N/A | 11.9 (7) | 6.78 (4) | N/A | N/A |
| ViT | 4.97 (8) | 3.39 (2) | 1.69 (1) | 6.78 (4) | 4.55 (1) | N/A |
| VGG | 4.35 (7) | 5.08 (3) | 5.08 (3) | N/A | 4.55 (1) | N/A |
| DenseNet | 4.35 (7) | 1.69 (1) | 3.39 (2) | N/A | 9.09 (2) | 20.0 (2) |
| MobileNet | 3.73 (6) | N/A | N/A | 1.69 (1) | 9.09 (2) | 30.0 (3) |
| XceptionNet | 2.48 (4) | N/A | 1.69 (1) | 3.39 (2) | 4.55 (1) | N/A |
| PWC-Net | 2.48 (4) | N/A | 6.78 (4) | N/A | N/A | N/A |
| ConvNeXt | 1.86 (3) | 3.39 (2) | 1.69 (1) | N/A | N/A | N/A |
| ViViT | 1.86 (3) | 3.39 (2) | 1.69 (1) | N/A | N/A | N/A |
| Single use | 14.9 (24) | 13.6 (8) | 8.47 (5) | 15.3 (9) | 9.09 (2) | N/A |
Categories may overlap for individual studies. Categorical variables are presented as their relative (%) and absolute frequencies (n).
CNN, convolutional neural network; ViT, vision transformer; ViViT, video vision transformer; N/A, not applicable.
Table 2.
Included deep learning studies aggregated by clinical task being investigated, whether external validation was applied, and what type of training data were used
| Clinical target per task | Counts % (n) |
|---|---|
| Prediction of disease or mortality | 36.6 (59) |
| Valvular heart disease | 35.6 (21) |
| Non-ischaemic cardiomyopathy | 22.0 (13) |
| Other structural heart disease | 16.9 (10) |
| Heart failure | 16.9 (10) |
| Ischaemic cardiomyopathy | 13.6 (8) |
| Pulmonary vascular disease | 5.08 (3) |
| Medical device | 5.08 (3) |
| Mortality | 3.39 (2) |
| Atherosclerotic disease | 1.69 (1) |
| Arrhythmias | 1.69 (1) |
| Replication of established measures | 36.6 (59) |
| Systolic function | 71.2 (42) |
| Chamber volumes | 18.6 (11) |
| Cardiac geometry | 18.6 (11) |
| Event timing | 15.3 (9) |
| Diastolic function | 8.47 (5) |
| Demographic and anthropometrics | 5.08 (3) |
| Circulating biomarkers | 1.69 (1) |
| Segmentation | 36.6 (59) |
| Cardiac chambers | 89.8 (53) |
| Valves | 15.3 (9) |
| Vessels | 5.08 (3) |
| Validation type | |
| External | 53.4 (86) |
| Internal only | 46.6 (75) |
| Reported sample size | |
| Individuals | 83.2 (134) |
| Echocardiographic videos | 54.7 (88) |
| Echocardiographic studies | 21.1 (34) |
Categories may overlap for individual studies. Categorical variables are presented as their relative (%) and absolute frequencies (n). External datasets refer to independent datasets used for model testing only; studies in which the model was retrained or fine-tuned on the same dataset were not considered to have external validation.
Figure 2.

Timeline of published articles in the application of deep learning on echocardiography and their relation to advancements within the deep learning field. BERT, bidirectional encoder representations from transformers; ViT, vision transformer; CLIP, contrastive language-image pre-training; MAE, masked auto-encoder; SAM, segment anything. Classic CNN variants included 2D CNN, VGG, ResNet, DenseNet, EfficientNet, InceptionV3, MobileNetV2, XceptionNet, DCNN, 1D CNN, ConvNeXt, PWC-Net, and YoloV3, all of which are built on variations of convolutional layers for feature extraction in image or sequential data. Encoder-Decoders included U-Net, DeepLabV3, HRNet, Few-Shot Segmentation, and generic encoder modules, these networks are often used in segmentation and dense prediction. Spatiotemporal CNNs included 3D CNN, R2 + 1D, S3D, and SlowFast, all of which are designed to capture both spatial and temporal features for analysis of video or 3D data. Transformers included both ViT and ViViT (video vision transformer).
Availability of imaging views and clinically relevant information
Most studies focused on the apical 4-chamber view, with apical 2-chamber being the second most assessed view, followed closely by parasternal long axis (Figure 3). The total number of the cardiac views used in each study based on categorization of the model goal is shown in Supplementary material online, Figure S2. For those studies aiming to predict presence of disease or all-cause mortality over time, study participant characteristics were reported in 40 out of 59 articles. Further information on the proportion of reported information of interest is detailed in Supplementary material online, Table S2.
Figure 3.

Proportion of the usage of individual cardiac views per study. The x-axis indicates the proportion of studies that used each specific chamber view. The number inside of each bar is the exact number of studies that used that view for each separate task. A) Prediction of disease or mortality. B) Replication of established echocardiographic measures. C) Segmentation of cardiac chambers. D) Classification of cardiac chamber views. E) Assessment of echocardiogram image quality.
Prediction of prevalent disease or all-cause mortality
A multilevel meta-regression analysis of proportions for studies predicting prevalent disease or all-cause mortality was conducted in two groups: one reporting model performance as overall accuracy (nstudies = 22, ntargets = 36) and the other using AUC (nstudies = 23, ntargets = 70). Studies aggregated by target being predicted and ordered by accuracy are provided in Table 3. Residual heterogeneity decreased stepwise with the addition of moderators to the model. The inclusion of specific DL architectures resulted in high heterogeneity (I2accuracy = 99.9%, I2AUC = 98.8%), which decreased with the addition of the target (I2accuracy = 98.4%, I2AUC = 98.1%), and further decreased with the addition of participants used in model training, video resolution, number of frames, and batch size (I2accuracy = 76.8%, I2AUC = 82.8%). Inclusion of the last batch of moderators additionally resolved any differences in performance across model architectures. Time dependent analysis revealed that model generalizability for prognostic tasks has increased in more recent studies (see Supplementary material online, Figure S3).
Table 3.
Subgroup of studies for prediction task aggregated by model target and performance
| First author, year of publication |
Details | Sample size (P/S/V)* | Proportion women (%) |
Population mean age | Network architecture | Performance metric | Value as reported |
|---|---|---|---|---|---|---|---|
| Bicuspid aortic valve | |||||||
| Holste, 2025 | 264 (24 405) P | 47 | 69 | ConvNeXt | AUC | 0.83 [0.65–0.96] | |
| Vukadinovic, 2026 | NR (108 913) P | NR | NR | ViT | AUC | 0.82 [0.73–0.90] | |
| Calcification | |||||||
| Vukadinovic, 2026 | Mitral annular | NR (108 913) P | NR | NR | ViT | AUC | 0.96 [0.94–0.98] |
| Yuan, 2023 | Coronary artery | 867 (1635) P | 37 | 72 | R2 + 1D | AUC | 0.85 [0.76–0.93] |
| Cardiac amyloidosis | |||||||
| Hwang, 2022 | Light-chain | 81 (930) P | 46 | 51 | 2D CNN | AUC | 1.00 |
| Slivnick, 2025 | 2035 (10 278) P | 53 | 67 | R2 + 1D | AUC | 0.93 [0.92–0.95] | |
| Chao, 2024 | 197 (381) P | 27 | 69 | ResNet | Overall accuracy | 92.7% ± 7.5% | |
| Zhang, 2018 | 179 (983) V | 55 | 57 | VGG | AUC | 0.87 | |
| Duffy, 2022 | 950 (6461) V | 54 | 65 | ResNet | AUC | 0.79 | |
| Cardiac function | |||||||
| Holste, 2025 | A) LV dysfunction B) RV dysfunction |
2270 (24 405) P 3156 (24 405) P |
47 | 69 | ConvNeXt | AUC | 0.99 [0.98–0.99] 0.94 [0.92–0.96] |
| Vukadinovic, 2026 | RV dysfunction | NR (108 913) P | NR | NR | ViT | AUC | 0.94 [0.88–1.00] |
| Liastuti, 2022 | Heart failure | 90 (138) P | 31 | 50 | VGG | Overall accuracy | 93.0% |
| Holste, 2025 | LV dysfunction | 3298 (24 405) P | 47 | 69 | ConvNeXt | AUC | 0.92 [0.90–0.93] |
| He, 2024 | Reduced EF | 152 (927) V | NR | NR | R2 + 1D | AUC | 0.92 [0.89–0.94] |
| Cassianni, 2024 | Preserved EF | 646 (1284) P | NR | NR | 3D CNN | Sensitivity | 89.8 [87.5–92.5] |
| Akan, 2025 | Reduced EF | NR (10 030) P | NR | NR | ViViT | Overall accuracy | 87.0% |
| Vukadinovic, 2026 | Diastolic dysfunction | NR (108 913) P | NR | NR | ViT | AUC | 0.86 [0.81–0.90] |
| Cheng, 2022 | LV dysfunction | 928 (3554) V | NR | NR | 3D CNN | Overall accuracy | 86.0% |
| Akerman, 2025 | Preserved EF | 240 (496) P | 55 | 75 | 3D CNN | AUC | 0.80 [0.76–0.80] |
| Ramadhan, 2024 | Heart failure | 79 (124) V | NR | NR | ViT | Overall accuracy | 77.3% |
| Petmezas, 2025 | Reduced EF | 145 (219) P | NR | 70 | TimeSformer | Overall accuracy | 73.0% ± 0.81% |
| Decoodt, 2024 | Heart failure | 2109 (2109) P | NR | NR | 3D CNN | Overall accuracy | 70.0% |
| Shad, 2021 | RV failure | 182 (723) P | 22 | 57 | 3D CNN | Specificity | 52.7% |
| Cardiomyopathies | |||||||
| Liu, 2023 | Dilated | 310 (1276) P | 29 | 52 | InceptionV3 | AUC | 1.00 |
| Oikonomou, 2025 | Transthyretin amyloid | 8842 (290 657) V | 49 | 69 | ResNet | AUC | 0.99 [0.99–1.00] |
| Liu, 2023 | Hypertrophic | 121 (1276) P | 29 | 52 | InceptionV3 | AUC | 0.99 |
| Hwang, 2022 | Hypertrophic | 191 (930) P | 46 | 51 | 2D CNN | AUC | 0.98 |
| Almandani, 2024 | Hypertrophic | 116 (233) V | NR | NR | SlowFast + I3D | AUC | 0.98 |
| Hwang, 2022 | Hypertensive | 112 (930) P | 46 | 51 | 2D CNN | AUC | 0.96 |
| Oikonomou, 2025 | Transthyretin amyloid | 112 (984) P | 44 | 74 | ResNet | AUC | 0.93 [0.90–0.96] |
| Zhang, 2018 | Hypertrophic | 495 (2739) V | 55 | 57 | VGG | AUC | 0.93 |
| Chen, 2023 | Hypertensive | 185 (297) P | 50 | 43 | 3D CNN | Overall accuracy | 91.9% |
| Duffy, 2022 | Hypertrophic | 2344 (6461) P | 54 | 65 | ResNet | AUC | 0.89 |
| Oikonomou, 2025 | Hypertrophic | 46 398 (290 657) V | 49 | 69 | ResNet | AUC | 0.89 [0.84–0.94] |
| Velmulapalli, 2025 | Hypertrophic | 1601 (8704) P | 53 | 59 | R2 + 1D | AUC | 0.87 [0.81–0.91] |
| Akita, 2024 | Hypertrophic | 160 (323) P | 41 | 55 | DCNN | AUC | 0.86 [0.76–0.96] |
| Holste, 2024 | Hypertrophic | 2280 (9122) P | 49 | 69 | ResNet | AUC | 0.81 [0.79–0.83] |
| Laumer, 2022 | Takotsubo | 114 (228) P | 92 | 68 | Auto-encoder | Overall accuracy | 75.5% ± 2.7% |
| Congenital heart defects | |||||||
| Kempny, 2019 | A. TGA B. Congenitally corrected TGA |
A. 92 (132) P B. 40 (132) P |
41 | 42 | 2D CNN | Overall accuracy | A. 100% B. 100% |
| Liu, 2023 | Atrial septal defect | 113 (1276) P | 29 | 52 | InceptionV3 | AUC | 0.97 |
| Dilation | |||||||
| Vukadinovic, 2026 | Aortic root | NR (108 913) P | NR | NR | ViT | AUC | 0.97 [0.94–0.99] |
| Diller, 2022 | RV | 308 (825) P | 72 | 51 | 2D CNN | Overall accuracy | 92.3% |
| Vukadinovic, 2026 | A) IVC B) RV C) RA D) LA |
NR (108 913) P | NR | NR | ViT | AUC | 0.86 [0.81–0.91] 0.85 [0.80–0.90] 0.77 [0.74–0.81] 0.73 [0.70–0.75] |
| Medical devices | |||||||
| Vukadinovic, 2026 | A. MitraClip B. Transcatheter aortic valve replacement C. Pacemaker |
NR (108 913) P | NR | NR | ViT | AUC | A. 0.98 [0.94–1.00] B. 0.97 [0.90–1.00] C. 0.84 [0.81–0.87] |
| Christensen, 2024 | A. Transvenous aortic valve replacement B. MitraClip C. Pacemaker |
NR (224 685) P | 43 | 66 | ConvNeXt | AUC | A. 0.92 [0.91–0.92] B. 0.97 [0.97–0.97] C. 0.84 [0.84–0.84] |
| Ghorbani, 2020 | Pacemaker | 431 (3223) P | 48 | 61 | ResNet | AUC | 0.89 |
| Vafaeezadeh, 2021 | Prosthetic mitral valve | 447 (2044) P | NR | NR | EfficientNet | AUC | 1.00 |
| Mortality | |||||||
| Valsaraj, 2023 | A. 1-year B. 3-year C. 5-year |
A. 539 (3626) P B. 839 (2937) P C. 958 (2252) P |
35 | 66 | ResNet | Overall accuracy | A. 82.0% B. 81.0% C. 85.0% |
| Mou, 2026 | Pulmonary hypertension patients | 278 (586) P | 47 | 61 | ResNet | AUC | 0.82 [0.74–0.90] |
| Cerna, 2021 | 1-year | 6132 (42 095) P | NR | NR | 3D CNN | AUC | 0.76 [0.74; 0.77] |
| Myocardial infarction | |||||||
| Hamila, 2022 | NR (162) V | NR | NR | 3D CNN | Overall accuracy | 90.9% | |
| Muraki, 2022 | Acute | 99 (202) V | 31 | 68 | VGG | Overall accuracy | 85.1% |
| Laumer, 2022 | Acute | 114 (228) P | 92 | 68 | Auto-encoder | Overall accuracy | 74.1% ± 3.5% |
| Liu, 2023 | Prior | 406 (1276) P | 29 | 52 | InceptionV3 | AUC | 0.99 |
| Pericardial effusion | |||||||
| Holste, 2025 | 1027 (24 405) P | 47 | 69 | ConvNeXt | AUC | 0.94 [0.89–0.98] | |
| Potter, 2023 | 37 (76) V | 42 | 54 | YoloV3 | Overall accuracy | 91.0% [73.0–99.0] | |
| Vukadinovic, 2026 | NR (108 913) P | NR | NR | ViT | AUC | 0.89 [0.77–0.90] | |
| Pulmonary arterial hypertension | |||||||
| Diller, 2022 | 450 (825) P | 72 | 51 | 2D CNN | Overall accuracy | 100% | |
| Zhang, 2018 | 584 (3071) V | 55 | 57 | VGG | AUC | 0.85 | |
| Regional wall motion abnormalities | |||||||
| Holste, 2025 | 2195 (24 405) P | 47 | 69 | ConvNeXt | AUC | 0.98 [0.97–0.99] | |
| Gul, 2026 | 91 (153) P | NR | NR | ResNet | Overall accuracy | 94.5% | |
| Slivnick, 2024 | 10 722 (25 529) S | 52 | 71 | 3D CNN | Overall accuracy | 92.0% [87.0–96.0] | |
| Sahashi, 2025 | 678 (1453) P | 42 | 56 | R2 + 1D | AUC | 0.87 [0.82–0.92] | |
| Sanjeevi, 2023 | 47 (97) V | NR | NR | 3D CNN | Precision | 0.82 | |
| Huang, 2020 | 576 (5772) V | 49 | 64 | DenseNet | Overall accuracy | 81.6% [80.4–82.8] | |
| Sun, 2023 | 55 (137) P | NR | NR | ResNet | Overall accuracy | 76.2% ± 0.06% | |
| Stenosis | |||||||
| Holste, 2025 | A) Mitral B) Aortic |
901 (24 405) P 2020 (24 405) P |
47 | 69 | ConvNeXt | AUC | A) 1.00 [1.00–1.00] B) 1.00 [0.99–1.00] |
| Park, 2025 | Aortic | 6463 (8427) P | 50 | 68 | R2 + 1D | Overall accuracy | 97.0% |
| Yang, 2022 | Aortic | 499 (3491) S | 43 | 69 | S3D | Overall accuracy | 96.0% [95.0–97.0] |
| Vukadinovic, 2026 | Aortic | NR (108 913) P | NR | NR | ViT | AUC | 0.96 [0.92–0.99] |
| Holste, 2023 | Aortic | 1213 (5749) P | 48 | 70 | ResNet | AUC | 0.95 [0.94; 0.96] |
| Holste, 2024 | Aortic | 1609 (9122) P | 49 | 69 | ResNet | AUC | 0.95 [0.88–0.99] |
| Yang, 2022 | Mitral | 219 (3491) S | 43 | 69 | HRNet | Overall accuracy | 94.0% [93.0–96.0] |
| Vukadinovic, 2026 | Mitral | NR (108 913) P | NR | NR | ViT | AUC | 0.92 [0.86–0.98] |
| Dai, 2023 | Aortic | (16 066) P | 42 | 66 | ResNet | AUC | 0.88 ± 0.01 |
| Ahmadi, 2024 | Aortic | (2247) P | NR | NR | ResNet | Overall accuracy | 83.8% |
| Gu, 2025 | Aortic | NR (2572) S | NR | 59 | R2 + 1D | Overall accuracy | 79.7% |
| Vafaeezadeh, 2023 | Mitral | 1349 (1773) P | NR | NR | ViViT | Overall accuracy | 64.1% |
| Duffy, 2022 | Aortic | 1061 (6461) P | 54 | 65 | ResNet | PR-AUC | 0.08 |
| Oikonomou, 2024 | Progression—aortic | 4452 (12 599) P | 47 | 70 | ResNet | AUC | 0.07 [0.05–0.09] |
| Valve regurgitation | |||||||
| Holste, 2025 | A) Mitral B) Tricuspid |
4612 (24 405) P 4570 (24 405) P |
47 | 69 | ConvNeXt | AUC | A) 0.92 [0.91–0.94] B) 0.91 [0.90–0.93] |
| Vukadinovic, 2026 | A) Mitral B) Aortic C) Tricuspid |
NR (108 913) P | NR | NR | ViT | AUC | A) 0.91 [0.89–0.93] B) 0.89 [0.80–0.97] C) 0.88 [0.86–0.91] |
| Long, 2025 | Aortic | 9196 (52 672) S | 52 | 61 | R2 + 1D | Overall accuracy | 89.3% |
| Yang, 2022 | Aortic | 434 (3491) S | 43 | 69 | U-Net | Overall accuracy | 88.0% [0.86–0.90] |
| Holste, 2025 | Atrial | 1917 (24 405) P | 47 | 69 | ConvNeXt | AUC | 0.85 [0.81–0.89] |
| Cheng, 2022 | Aortic | 738 (3554) V | NR | NR | 3D CNN | Overall accuracy | 83.0% |
| Yang, 2022 | Mitral | 928 (3491) S | 43 | 69 | U-Net | Overall accuracy | 81.0% [0.79–0.83] |
| Long, 2025 | A) Mitral B) Tricuspid |
19 110 (52 672) S 21 084 (52 672) S |
52 | 61 | R2 + 1D | Overall accuracy | A) 79.7% B) 75.5% |
| Li, 2026 | Transcatheter edge-to-edge repair | 194 (633) P | 43 | 64 | ViViT | Overall accuracy | 73.3% [66.3–80.4] |
| Vrudhula, 2024 | Mitral | 47 576 (75 523) V | 43 | NR | R2 + 1D | Overall accuracy | 63.1% |
| Vrudhula, 2025 | Tricuspid | 57 867 (478 271) V | 44 | NR | R2 + 1D | Overall accuracy | 62.6% |
| Valve prolapse | |||||||
| Al-Alusi, 2026 | Mitral | 783 (16 902) P | 38 | 61 | MoViNet | AUC | 0.97 [0.95–0.99] |
| Wu, 2024 | Mitral | 183 (473) P | NR | NR | ResNet | Overall accuracy | 94.0% |
| Single time | |||||||
| Vukadinovic, 2026 | A) Elevated left ventricular pressure B) Elevated RV pressure |
NR (108 913) P | NR | NR | ViT | AUC | A) 0.94 [0.88–0.99] B) 0.80 [0.78–0.82] |
| Park, 2025 | LV outflow tract obstruction | 290 (722) P | 34 | 65 | R2 + 1D | AUC | 0.93 [0.92–0.95] |
| Holste, 2025 | A) Increased LV size B) Increased LV wall thickness C) Increased LA size D) Increased RA size |
1553 (24 405) P 3575 (24 405) P 6190 (24 405) P 3726 (24 405) P |
47 | 69 | ConvNeXt | AUC | A) 0.91 [0.88–0.93] B) 0.89 [0.88–0.94] C) 0.90 [0.88–0.92] D) 0.75 [0.72–0.78] |
| Huang, 2025 | Atrial high rate episode | NR (117) P | 60 | 76 | ResU-Net | AUC | 0.85 |
| Ghorbani, 2020 | A) LA dilation B) Left ventricular hypertrophy |
566 (3223) P 1091 (3223) P |
48 | 61 | ResNet | AUC | A) 0.86 B) 0.75 |
| Katsushika, 2021 | Cardiac sarcoidosis | 50 (199) P | 54 | 65 | R2 + 1D | Overall accuracy | 70.7% [54.5–83.9] |
| Sahashi, 2025 | Myocardial scarring | 614 (1453) P | 42 | 56 | R2 + 1D | AUC | 0.7 [0.61–0.78] |
| Chao, 2024 | Constrictive pericarditis | 184 (381) P | 27 | 69 | ResNet | Overall accuracy | 62.1% ± 21.5% |
Performance of subgroup for prediction tasks aggregated by model targets, including further details on specific diseases or subcategories of a disease as disclosed by the authors. Sample size is reported as either P, S, or V (participants, studies, or videos, respectively) and values shown are the number of individuals with the specific target and the total sample size for that study in parenthesis.
ACC, overall accuracy; CCTGA, congenitally corrected transposition of the great arteries; HF, heart failure; LA, left atrium; LV, left ventricle; MV, mitral valve; RA, right atrium; rEF, reduced ejection fraction; RV, right ventricle; TAVR, transcatheter aortic valve replacement; TGA, transposition of the great arteries; IVC, inferior vena cava.
Segmentation of cardiac structures
The overall performance of segmentation models were an external validation was performed (n = 21) can be seen in Figure 4, where considerable between-study heterogeneity (I2 = 98.2%) was observed. Subgroup analysis by segmentation target did not reduce heterogeneity (I2left atrium = 97.5%; I2left ventricle = 94.9%), which was also the case with the addition of moderators for the basic architecture, the area of the segmented echocardiogram and number of participants used in model training (I2 = 98.8%). A test of moderators revealed that the included moderators did not explain any variability in the outcome (P for model comparison=0.99). There were no differences in model performance based on the area of the echocardiogram being segmented or the DL architecture applied after the inclusion of input-related moderators. A meta-analysis showing the performance of all studies, including those that did not test their method on an external dataset, is available in Supplementary material online, Figure S4. Longitudinal assessment of Dice coefficients for the four major cardiac chambers indicates that external performance of DL segmentation models has decreased over the past seven years (see Supplementary material online, Figure S5). Meta-analysis for segmentation of the mitral valve and an overview of tasks performed only once is available in Supplementary material online, Figure S6.
Figure 4.

Meta-analysis of the dice coefficient as a measure of performance for segmentation models stratified by cardiac chamber. DC, dice coefficient; CI, confidence interval. Proportions were calculated using the testing dataset. Sample size for all studies was provided in participants or transthoracic echocardiography studies. Studies reporting sample size in echocardiographic studies were included only when it could be reasonably interpreted from the text that a one-to-one correspondence with participants was intended. Such studies are marked with an *.
Replication of established measurements in echocardiography
In studies that assessed model accuracy for LVEF prediction using the mean absolute error (%, nstudies=9), a multilevel meta-regression analysis with the basic model architecture as moderator showed high heterogeneity (I2 = 98.1%). There were no significant differences in the performances of the different architectures (VGG, ConvNeXt, R2 + 1D, 3D CNN, U-Net, and PWC-Net) applied in these DL models. Meta-regression analysis showed no improved performance based on target variable. There were no significant differences observed between studies timing end-systole and end-diastole, nor between studies predicting volumes of different cardiac chambers (see Supplementary material online, Figure S7). For comparable studies, time dependent analysis of studies estimating LVEF demonstrates progressive gains in both internal and external validation performance (see Supplementary material online, Figure S8).
Classification of major cardiac imaging views
A meta-analysis of proportions was performed for those studies where the overall classification accuracy was available for individual cardiac chamber views and the models were externally validated (n = 9). The model showed high heterogeneity when classification of all chambers was analysed (I2 = 75.8%). Separating the analysis into individual chambers did not resolve the high heterogeneity (Figure 5). There were no differences due to target cardiac chamber or architecture employed. A meta-analysis including all studies, internally or externally validated, is available in Supplementary material online, Figure S9. Over time, models designed for chamber view classification show enhanced generalization performance, despite a gradual decline in performance within derivation cohorts (see Supplementary material online, Figure S10).
Figure 5.

Meta-analysis of the overall accuracy for classification of cardiac chamber views. Acc, accuracy; CI, confidence interval. Proportion of correct classifications were calculated with the test dataset. Sample size for all studies was provided in participants.
Assessment of echocardiogram video quality
There was a low number of comparable studies available in quality assessment (n = 4). However, meta-analysis was still performed and it showed no differences in the performance of different architectures (MobileNetV2, ResNet, and DenseNet). Overall, accuracy in quality assessment was lower than accuracy in studies focusing on replication of established measures or disease prediction. Additionally, there was high heterogeneity that could not be further resolved (Figure 6).
Figure 6.

Meta-analysis of the overall agreement of the fully automated video-based deep learning models with human measures of quality. Acc, accuracy; CI, confidence interval. Proportion of classification of quality in agreement with expert assessment was calculated using the test dataset. Sample size for all studies was provided in participants. Studies marked with an * are those were accuracy was estimated based on the provided individual accuracies per view.
Sensitivity analyses and risk of publication bias
In studies predicting death or mortality that used accuracy as their main performance metric, there were no instances of Cook’s D above 1. Modelling of replication studies showed one instance of Cook’s D > 1, after removal heterogeneity could not be calculated due to low power. Five studies focusing on segmentation tasks had a Cook’s D above the threshold of 1. After removal, heterogeneity was fully resolved (I2 = 0.00%). There were no chamber view classification studies or quality assessment studies with a Cook’s D over 1. Funnel plots assessing potential small-study effects are provided in Supplementary material online, Figure S11 and suggest that observed study effects are largely consistent with what would be expected under sampling variation alone, without evidence of substantial asymmetry. Because conventional funnel plots are difficult to interpret in diagnostic and prediction-model studies with heterogeneous metrics, tasks, and validation designs, these analyses were considered exploratory and were not interpreted as definitive evidence for or against publication bias.
Discussion
This systematic review and meta-analysis examined the current literature regarding the application of fully automated DL models to echocardiograms. To the knowledge of the authors, and within the scope of the pre-defined inclusion criteria, this is the first meta-analysis focusing specifically on fully automated, video-based analysis of echocardiography using DL. The primary focus of the analyses was the quantification of the performance of these models and the evaluation of factors influencing their accuracy. Inclusion of a large number of studies enabled a detailed investigation of various non-comparable tasks like prediction, replication, segmentation, classification, and quality assessment separately. The results demonstrated that DL models consistently achieve a good accuracy across a range of echocardiographic tasks. However, there exists substantial heterogeneity in performance that could not be resolved. This variability likely reflects systematic differences across studies, including variation in datasets, annotation standards, vendor-specific imaging characteristics, pre-processing pipelines, validation strategies, and reporting practices. In addition, publication bias, whereby studies with significant findings are more likely to be published, may have resulted in an overestimation of the effectiveness of certain models. For specific tasks, such as the segmentation of the right ventricle, for which fewer studies are available compared with more commonly assessed cardiac chambers like the left ventricle, results may be more susceptible to chance or variability within the data.26
Input to a DL network, constrained to number of frames, and echocardiogram resolution, and was found to have no significant influence on model performance when examined in isolation across the studies included in this review. This observation could have several explanations. First, models trained on smaller datasets may have been better optimized to handle what are conventionally considered ‘lower quality’ inputs, thereby mitigating performance differences.27 However, it is also possible that these models overfit the limited data, resulting in over-optimistic performance estimates. Second, current hardware limitations may have prevented the full use of larger or higher-quality inputs, leading to a trade-off in other computationally intensive features that enhance model performance.28 Third, there may be a lack of studies exploring the extremes of input size or quality. Compounding this issue, a considerable number of studies failed to report detailed input specifications, making it difficult to fully assess their impact. This lack of transparency was likely driven by the absence of standardized reporting requirements at the time of publishing for the articles. Notably, a temporal trend was observed whereby more recent publications demonstrated substantially improved reporting quality and lower assessed risk of bias. This improvement is likely attributable to the growing adoption of structured reporting and methodological guidance frameworks, including TRIPOD-AI, PRIME 2.0, and the TRUE-AIM report card. As adherence to such standards becomes more widespread, it is anticipated that methodological heterogeneity across studies will continue to decline over time.29–31
The studies included in this review employed two primary methodological approaches for LVEF estimation: one involving LV segmentation followed by computation using LVEDV and LVESV, consistent with standard clinical practice,32 and another based on direct regression of LVEF values from echocardiographic video data without intermediate volumetric analysis. Although the scope of meta-analysis was limited by heterogeneity in reporting, a consistent observation across multiple investigations is that DL-based measurements demonstrate lower variability compared with human interpretation.33,34 In contrast to the well-documented interobserver variability among expert readers in routine echocardiographic assessment,35 several studies have shown that automated DL approaches yield more reproducible estimates, in some cases with variability equal to or lower than that observed between experienced clinicians.36 This improved consistency represents a potentially meaningful advantage of DL systems.
The findings of this systematic review should be interpreted in the context of the current landscape in which several DL-based echocardiography tools have already achieved regulatory approval,37 including systems such as Caption Guidance Software (Caption Health, Inc., USA) for automated image acquisition and view guidance, EchoGo® Core (Ultromics Ltd., United Kingdom) for automated quantification, and Us2.ai (Us2.ai, Singapore) for comprehensive chamber and functional assessment. In contrast to many studies included in this review, which could only be validated in internal cohorts, these commercial systems have undergone extensive multicentre validation across diverse devices and populations to meet stringent regulatory requirements. Evidence from both commercial implementations and the studies analysed in this review suggests that DL applications for measurement automation and functional assessment can achieve reproducible performance with limited marginal gains from further incremental optimization. Accordingly, these domains appear to represent realistic opportunities for clinical adoption, provided that deployment is accompanied by appropriate workflow integration and post-implementation performance monitoring.
As these DL systems progress towards broader clinical integration, evaluation frameworks should then shift to prioritize endpoints that capture real-world utility. Rather than focusing solely on improvements in measurement precision, models should be assessed on their ability to influence patient management, streamline clinical decision making, and enhance workflow efficiency, such as reducing time to diagnosis or treatment initiation. Such outcome-oriented evaluation is essential to determine whether DL tools provide tangible benefits within healthcare systems and to guide development towards applications with meaningful clinical impact.
Despite considerable promise, integrating DL-based tools into routine echocardiographic workflows still faces considerable challenges. One fundamental barrier is the opacity of many DL models; their ‘black box’ nature can limit clinician trust and acceptance when explanations for specific outputs are not readily interpretable, hindering routine use in high-stakes decision making.38 There are also ethical, regulatory, and legal considerations to take into account, ranging from data governance and bias mitigation to liability for AI-assisted decisions, which compound the difficulty of deploying DL tools at scale, emphasizing the need for structured governance and real-world validation prior to broad clinical adoption.39
Although DL applications used to improve measurement acquisition appear sufficiently mature for focused clinical implementation, there are still domains where current approaches remain immature. For example, tasks such as diagnosing stenosis was found to be relatively difficult compared with other conditions. This is consistent with established methods in clinical practice, where accurate diagnosis of the condition typically relies on the combination of 2D and Doppler imaging.40–42 The DL models in these studies, however, did not have access to the latter. These findings underscore that while DL has demonstrated clear promise in measurement automation and function assessment, substantial methodological and clinical challenges remain in domains requiring richer multimodal data or deeper pathophysiological inference.
Contemporary advances in DL are increasingly driven by transformer-based architectures and large-scale foundation models; however, their adoption within echocardiography remains limited. Among the 160 full-text articles included in this review, only 16 employed state-of-the-art architectures to develop DL-based tools with potential for physician assistance, revealing a marked methodological gap between echocardiography research and the broader DL literature. This lag suggests that many current echocardiographic applications have not yet capitalized on recent advances in model design, scalability, and representation learning. However, recent work has increasingly explored multi-task DL frameworks as one strategy to more fully leverage the flexibility of DL.43–45 In contrast to the predominantly single-task approaches represented in our analysis, these models need to be trained on very large quantities of data and are designed to learn shared representations, potentially improving efficiency and consistency within a unified pipeline. Such approaches may offer one avenue to mitigate some of the heterogeneity observed across studies. While still emerging and not yet sufficiently represented to influence the quantitative results of this work, these developments signal a methodological broadening of the field that may shape future performance and validation patterns.
Most of the DL research in echocardiography focuses on incremental performance improvements for tasks that are advanced and technically mature and, in some cases, approved by regulatory authorities. While such work remains important for validation, robustness, and generalizability, the predominance of studies revisiting similar tasks―often using overlapping datasets and comparable model architectures―suggests that further methodological gains may yield diminishing returns in terms of incremental clinical benefit. In contrast, only few studies have focused on underexplored disease entities, longitudinal risk stratification, or decision-critical clinical questions where DL-based approaches might address unmet needs in echocardiographic practice. Furthermore, incorporation of multiple views remains limited. Shifting a greater proportion of research effort towards these higher-impact domains may better align methodological advances with clinically meaningful outcomes and help bridge the gap between technical performance and real-world utility.46
While DL holds clear promise to reduce physician workload and to augment clinical interpretation, most existing applications remain confined to tasks that replicate established human assessments. However, DL methods are uniquely capable of identifying complex, high-dimensional patterns and temporal dynamics that may be imperceptible to human observers, enabling the detection of subtle phenotypic signatures of disease. Only a comparatively small number of studies have explored prognostic modelling or diagnostic tasks not routinely addressed using echocardiography; as a result, the rich information embedded in echocardiographic videos remains largely underutilized.
Evidence from other imaging domains illustrates the potential of this paradigm. For example, the MIRAI DL model developed for mammography demonstrated the ability to predict an individual’s risk of developing breast cancer up to five years in advance.47 Such findings suggest that medical imaging modalities contain relevant information beyond current human interpretation. In echocardiography, similar DL approaches may therefore enable detection of cardiovascular conditions and risk patterns not typically captured by standard clinical assessment. A small subset of studies included in this systematic review have already begun to explore such applications, including prognostic modelling and non-traditional tasks derived directly from echocardiographic data. However, these efforts remain the exception rather than the norm. This imbalance highlights both the early emergence of more exploratory, insight-driven applications and the largely untapped opportunity for future research to fully exploit the unique strengths of DL.
Strengths and limitations
Several limitations should be acknowledged. The exclusion of non-peer reviewed work meant that studies available only on preprint servers such as arXiv, where state-of-the-art developments in computer science are often reported, were not included in this systematic review. The methodological heterogeneity of included studies may have introduced publication bias. Although the application of Cook’s D helped to identify and mitigate the influence of outliers, inconsistencies in reporting remain a significant concern. Performance metrics for identical prediction targets were often reported using non-standardized formats, and in many cases, the absence of measures of variability, such as standard deviations or confidence intervals, precluded inclusion in the meta-analysis. Additionally, overlap in training datasets, derivative model development, and repeated use of the same validation cohorts across studies may have reduced the independence of some performance estimates and should be considered when interpreting the pooled results. Certain moderator analyses could not be conducted due to incomplete or insufficient reporting of key study characteristics. Importantly, this review is restricted to published studies and does not include proprietary or commercial DL software. The performance of these systems may more closely reflect the true achievable performance of DL in echocardiography, given the rigorous validation required to meet regulatory standards. Their exclusion represents a potential source of bias and should be considered when interpreting the generalizability and clinical applicability of the pooled estimates. Additionally, limited reporting on algorithm retraining constrains full assessment of model performance and generalizability.
Despite these challenges, which are consistent with previously reported limitations in applied DL research,48 a considerable number of studies met the inclusion criteria, enabling valuable insights into the functioning of DL models as automated tools in echocardiography. The formation of subcategories based on prediction tasks and model architectures facilitated comparative analyses and yielded clinically and technically relevant insights into the performance of DL models as fully automated tools in echocardiographic assessment.
Conclusion
This systematic review and meta-analysis demonstrate a growing and increasingly robust body of evidence supporting the application of DL in echocardiography across a broad spectrum of clinical tasks. The available evidence suggests that some of these applications may be approaching readiness for clinical integration. If successfully validated and implemented, they have the potential to improve consistency, reduce interobserver variability, and alleviate physician workload, particularly in resource-limited settings, while complementing rather than replacing clinical judgment. Greater research effort should be directed towards unexplored areas, including longitudinal risk stratification, multimodal approaches, and diagnostic tasks not traditionally addressed by echocardiography, where DL’s capacity to detect subtle patterns may unlock genuinely novel clinical insight. Realizing this potential will require prioritization of regulatory readiness, external validation, and transparent model interpretability to foster clinician trust and facilitate responsible clinical integration. If these conditions are met, DL stands to move beyond replicating human expertise and towards augmenting it in ways that meaningfully advance cardiovascular care.
Supplementary Material
Acknowledgements
This work is part of the thesis of Aída Romano-Martínez.
Contributor Information
Aida Romano-Martinez, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; Systems Medicine, Institute of Molecular Biology (IMB), Mainz, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany.
Silav Zeid, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany; Clinical Epidemiology and Systems Medicine, Centre for Thrombosis and Hemostasis (CTH), University Medical Centre of the Johannes Gutenberg-University, Mainz, Germany.
Mykhailo Krolevets, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; Systems Medicine, Institute of Molecular Biology (IMB), Mainz, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany.
Konstantin Kontohow-Beckers, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany.
Vincent ten Cate, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany; Clinical Epidemiology and Systems Medicine, Centre for Thrombosis and Hemostasis (CTH), University Medical Centre of the Johannes Gutenberg-University, Mainz, Germany.
Philipp Lurz, German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany; Centre for Cardiology—Cardiology I, University Medical Centre of the Johannes Gutenberg-University, Mainz, Germany.
Sandy Engelhardt, Department of Cardiology, Angiology and Pneumology, Heidelberg University Hospital, Heidelberg, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Heidelberg/Mannheim, Heidelberg, Germany.
Stefan Kramer, Institute of Computer Science, Johannes Gutenberg University, Mainz, Germany.
Sven-Oliver Troebs, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; Boehringer Ingelheim International GmbH, Ingelheim am Rhein, Germany.
Philipp S Wild, Preventive Cardiology and Preventive Medicine, Department of Cardiology, University Medical Centre of the Johannes Gutenberg-University, Mainz Langenbeckstr. 1, Mainz 55131, Germany; Systems Medicine, Institute of Molecular Biology (IMB), Mainz, Germany; German Centre for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany; Clinical Epidemiology and Systems Medicine, Centre for Thrombosis and Hemostasis (CTH), University Medical Centre of the Johannes Gutenberg-University, Mainz, Germany.
Supplementary material
Supplementary material is available at European Heart Journal – Digital Health.
Author contributions
P.S.W., P.L., S.K., and S.E. acquired funding for the study. A.R.M., V.t.C., S.Z., P.L., S.E., S.K., S.-O.T., and P.S.W. conceived and designed the study. P.S.W. supervised the work. A.R.M., S.Z., M.K., V.t.C., and K.K.B. conceived the analysis. A.R.M., S.Z., M.K., and K.K.B. conducted the analysis. A.R.M., S.-O.T., and P.S.W. drafted the manuscript. All authors critically reviewed the manuscript and approved the final draft.
Funding
The present work and A.R.-M., K.K.-B., and V.t.C. were funded by the German Federal Ministry of Research, Technology, and Space (BMFTR 03ZU1202LB, 03ZU1202JC, 03ZU1202AA, respectively) within the future cluster curATime. S.Z. was funded by the Carl-Zeiss-Stiftung within Multi-dimensionAI (CZS-Project number: P2022-08-010). P.S. Wild is principal investigator of the German Centre for Cardiovascular Research (DZHK), principal investigator of the BMFTR DIASyM research core (BMFTR 161L0217A, 031L0217A, 16LW0241K), principal investigator of the future cluster curATime (BMFTR 03ZU1202AA, 03ZU1202CD, 03ZU1202DB, 03ZU1202JC, 03ZU1202KB, 03ZU1202MB, and 03ZU1202OA), principal investigator of EPIC-AI (BMFTR 01EQ2401A) and principal investigator of Multi-dimensionAI (CZS-Project number: P2022-08-010), funded by the Carl-Zeiss-Stiftung.
Data availability
Data are available upon reasonable request to the corresponding author.
References
- 1. Mohamed AA, Arifi AA, Omran A. The basics of echocardiography. J Saudi Heart Assoc 2010;22:71–76. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2. Price S, Platz E, Cullen L, Tavazzi G, Christ M, Cowie MR, et al. Echocardiography and lung ultrasonography for the assessment and management of acute heart failure. Nat Rev Cardiol 2017;14:427–440. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Senni M, Rodeheffer RJ, Tribouilloy CM, Evans JM, Jacobsen SJ, Bailey KR, et al. Use of echocardiography in the management of congestive heart failure in the community. J Am Coll Cardiol 1999;33:164–170. [DOI] [PubMed] [Google Scholar]
- 4. Williams L, Frenneaux M, Steeds R. Echocardiography in hypertrophic cardiomyopathy diagnosis, prognosis, and role in management. Eur J Echocardiogr 2009;10:iii9–iii14. [DOI] [PubMed] [Google Scholar]
- 5. Price S, Nicol E, Gibson D, Evans T. Echocardiography in the critically ill: current and potential roles. Intensive Care Med 2006;32:48–59. [DOI] [PubMed] [Google Scholar]
- 6. Krishnamoorthy VK, Sengupta PP, Gentile F, Khandheria BK. History of echocardiography and its future applications in medicine. Crit Care Med 2007;35:S309–S313. [DOI] [PubMed] [Google Scholar]
- 7. Gillam LD, Marcoff L. Echocardiography: past, present, and future. Circ Cardiovasc Imaging 2024;17:e016517. [DOI] [PubMed] [Google Scholar]
- 8. Krittanawong C, Omar AMS, Narula S, Sengupta PP, Glicksberg BS, Narula J, et al. Deep learning for echocardiography: introduction for clinicians and future vision: state-of-the-art review. Life 2023;13:1029. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Song Y, Zheng S, Li L, Zhang X, Zhang X, Huang Z, et al. Deep learning enables accurate diagnosis of novel coronavirus (COVID-19) with CT images. IEEE/ACM Trans Comput Biol Bioinform 2021;18:2775–2780. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Esteva A, Robicquet A, Ramsundar B, Kuleshov V, DePristo M, Chou K, et al. A guide to deep learning in healthcare. Nat Med 2019;25:24–29. [DOI] [PubMed] [Google Scholar]
- 11. Raparthi M, Prasad Kasaraneni B, Reddy Gayam S, Kanth Kondapaka K, Pushyamitra Pattyam S, Putha S, et al. Deep learning for personalized medicine-enhancing precision health with AI. J Sci Technol 2020;1:82–90. [Google Scholar]
- 12. Kim SY, Park JE, Lee YJ, Seo HJ, Sheen SS, Hahn S, et al. Testing a tool for assessing the risk of bias for nonrandomized studies showed moderate reliability and promising validity. J Clin Epidemiol 2013;66:408–414. [DOI] [PubMed] [Google Scholar]
- 13. Cook RD. Detection of influential observation in linear regression. Technometrics 1977;19:15–18. [Google Scholar]
- 14. Egger M, Smith GD, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. BMJ 1997;315:629–634. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Viechtbauer W. Conducting meta-analyses in R with the metafor package. J Stat Softw 2010;36:1–48. [Google Scholar]
- 16. He K, Zhang X, Ren S, Sun J. Deep residual learning for image recognition. Proc IEEE Comput Soc Conf Comput Vis Pattern Recognit 2016:770–778. [Google Scholar]
- 17. Vaswani A, Shazeer N, Parmar N, Uszkoreit J, Jones L, Gomez AN, et al. Attention is all you need. Adv Neural Inf Process Syst 2017;30. [Google Scholar]
- 18. Devlin J, Chang M-W, Lee K, Toutanova K. Bert: Pre-training of deep bidirectional transformers for language understanding. Proc NAACL-HLT 2019:4171–4186. [Google Scholar]
- 19. Tan M, Le Q. Efficientnet: rethinking model scaling for convolutional neural networks. Int Conf Mach Learn. PmLR; 2019. p 6105–6114. [Google Scholar]
- 20. Brown T, Mann B, Ryder N, Subbiah M, Kaplan JD, Dhariwal P, et al. Language models are few-shot learners. Adv Neural Inf Process Syst 2020;33:1877–1901. [Google Scholar]
- 21. Dosovitskiy A, Beyer L, Kolesnikov A, Weissenborn D, Zhai X, Unterthiner T, et al. An image is worth 16 × 16 words: Transformers for image recognition at scale. arXiv preprint arXiv:201011929. 2020. 10.48550/arXiv.2010.11929 [DOI]
- 22. Radford A, Kim JW, Hallacy C, Ramesh A, Goh G, Agarwal S, et al. Learning transferable visual models from natural language supervision. Int Conf Mach Learn. PmLR; 2021. p 8748–8763. [Google Scholar]
- 23. He K, Chen X, Xie S, Li Y, Dollár P, Girshick R. Masked autoencoders are scalable vision learners. Proc IEEE Conf Comput Vis Pattern Recog. IEEE; 2022. p 15979–15988. [Google Scholar]
- 24. Rombach R, Blattmann A, Lorenz D, Esser P, Ommer B. High-resolution image synthesis with latent diffusion models. 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR). IEEE; 2022. p 10674–10685. [Google Scholar]
- 25. Kirillov A, Mintun E, Ravi N, Mao H, Rolland C, Gustafson L, et al. Segment anything. Proceedings of the IEEE International Conference on Computer Vision. IEEE; 2023. p 4015–4026. [Google Scholar]
- 26. Baker WL, Michael White C, Cappelleri JC, Kluger J, Coleman CI. Understanding heterogeneity in meta-analysis: the role of meta-regression. Int J Clin Pract 2009;63:1426–1434. [DOI] [PubMed] [Google Scholar]
- 27. Richter ML, Byttner W, Krumnack U, Wiedenroth A, Schallner L, Shenk J. (Input) size matters for CNN classifiers. Int Conf Artif Neural Netw 2021;0:133–144. [Google Scholar]
- 28. Thompson NC, Greenewald K, Lee K, Manso GF. The computational limits of deep learning. arXiv preprint arXiv:200705558. 2020;10
- 29. Collins GS, Moons KG, Dhiman P, Riley RD, Beam AL, Van Calster B, et al. TRIPOD+ AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ 2024;385:e078378. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30. Kagiyama N, Tokodi M, Hathaway QA, Arnaout R, Davies R, Dey D, et al. PRIME 2.0: proposed requirements for cardiovascular imaging-related multimodal-AI evaluation: an updated checklist. Cardiovascular Imaging 2026;19:225–251. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31. Kolossváry M, Smith EE, Reeves MJ, Layton A, Mills NL, Motwani M, et al. The transparent reporting and evaluation of artificial intelligence models (TRUE-AIM) report card: a quality assurance initiative of the American Heart Association journals to promote high-quality, reproducible artificial intelligence research. Circulation 2025;152:e311–e322. [DOI] [PubMed] [Google Scholar]
- 32. Thomas JD, Popović ZB. Assessment of left ventricular function by cardiac ultrasound. J Am Coll Cardiol 2006;48:2012–2025. [DOI] [PubMed] [Google Scholar]
- 33. Tromp J, Bauer D, Claggett BL, Frost M, Iversen MB, Prasad N, et al. A formal validation of a deep learning-based automated workflow for the interpretation of the echocardiogram. Nat Commun 2022;13:6776. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34. Salte IM, Østvik A, Olaisen SH, Karlsen S, Dahlslett T, Smistad E, et al. Deep learning for improved precision and reproducibility of left ventricular strain in echocardiography: a test-retest study. J Am Soc Echocardiogr 2023;36:788–799. [DOI] [PubMed] [Google Scholar]
- 35. Johri AM, Picard MH, Newell J, Marshall JE, King MEE, Hung J. Can a teaching intervention reduce interobserver variability in LVEF assessment: a quality control exercise in the echocardiography lab. JACC Cardiovasc Imaging 2011;4:821–829. [DOI] [PubMed] [Google Scholar]
- 36. Mor-Avi V, Blitz A, Schreckenberg M, Addetia K, Kebed K, Scalia G, et al. Deep learning assisted measurement of echocardiographic left heart parameters: improvement in interobserver variability and workflow efficiency. Int J Cardiovasc Imaging 2023;39:2507–2516. [DOI] [PubMed] [Google Scholar]
- 37. Hirata Y, Kusunose K. AI in echocardiography: state-of-the-art automated measurement techniques and clinical applications. JMA J 2025;8:141–150. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 38. Sehly A, Jaltotage B, He A, Maiorana A, Ihdayhid AR, Rajwani A, et al. Artificial intelligence in echocardiography: the time is now. Rev Cardiovasc Med 2022;23:256. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39. Nasef D, Nasef D, Sawiris V, Weinstein B, Garcia J, Toma M. Integrating artificial intelligence in clinical practice, hospital management, and health policy: literature review. J Hosp Manag Health Policy 2025;9:20. [Google Scholar]
- 40. Rana M. Aortic valve stenosis: diagnostic approaches and recommendations of the 2021 ESC/EACTS guidelines for the management of valvular heart disease–a review of the literature. Cardiol Cardiovasc Med 2022;6:315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 41. Skjaerpe T, Hegrenaes L, Hatle L. Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 1985;72:810–818. [DOI] [PubMed] [Google Scholar]
- 42. Saikrishnan N, Kumar G, Sawaya FJ, Lerakis S, Yoganathan AP. Accurate assessment of aortic stenosis: a review of diagnostic modalities and hemodynamics. Circulation 2014;129:244–253. [DOI] [PubMed] [Google Scholar]
- 43. Christensen M, Vukadinovic M, Yuan N, Ouyang D. Vision–language foundation model for echocardiogram interpretation. Nat Med 2024;30:1481–1488. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 44. Vukadinovic M, Chiu IM, Tang X, Yuan N, Chen TY, Cheng P, et al. Comprehensive echocardiogram evaluation with view primed vision language AI. Nature 2025;650:970–977. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45. Holste G, Oikonomou EK, Tokodi M, Kovács A, Wang Z, Khera R. Complete AI-enabled echocardiography interpretation with multitask deep learning. JAMA 2025;334:306–318. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 46. Yang F, Zhang Y, Gao Y, Wang B, Lin X, Chen X, et al. Deep learning-assisted aortic stenosis detection and grading based on multiview versus single-view echocardiography. Quant Imaging Med Surg 2025;15:11192–11204. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 47. Yala A, Mikhael PG, Strand F, Lin G, Smith K, Wan Y-L, et al. Toward robust mammography-based models for breast cancer risk. Sci Transl Med 2021;13:eaba4373. [DOI] [PubMed] [Google Scholar]
- 48. Aggarwal R, Sounderajah V, Martin G, Ting DSW, Karthikesalingam A, King D, et al. Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis. NPJ Digit Med 2021;4:65. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Data Availability Statement
Data are available upon reasonable request to the corresponding author.