Skip to main content

This is a preprint.

It has not yet been peer reviewed by a journal.

The National Library of Medicine is running a pilot to include preprints that result from research funded by NIH in PMC and PubMed.

bioRxiv logoLink to bioRxiv
[Preprint]. 2026 Sep 2:2026.08.28.747848. [Version 1] doi: 10.64898/2026.08.28.747848

A fiducial-based framework for precise MRI-guided stereotaxic targeting in nonhuman primates

Peyton Harmon, Reza Azadi
PMCID: PMC13684604  PMID: 42922567

ABSTRACT

Background

Accurate MRI-guided stereotaxic targeting in nonhuman primates requires reliable registration between MRI coordinates and stereotaxic space. We evaluated skull-fixed MR-compatible screw fiducials as a practical reference for this registration.

Results

Using a 3D-printed skull model with 28 fiducials and three internal targets, we compared offset translation, rigid registration, and affine registration under aligned and misaligned conditions. Offset translation was most sensitive to misalignment. Affine registration fit skull-surface fiducials closely, but rigid registration produced lower overall target errors. In vivo validation showed that implanted fiducials could be identified on MRI and re-measured during a later surgery.

Comparison with existing methods

This approach builds on previous fiducial-based stereotaxic methods by systematically comparing registration transforms, testing misalignment, evaluating fiducial number, and measuring accuracy at independent internal targets.

Conclusions

Skull-fixed fiducials provide a practical framework for MRI-to-stereotaxic registration. Rigid registration may offer the safest balance between correcting positioning differences and preserving accuracy at internal targets.

Highlights

  • MR-compatible screws provide an MRI-to-stereotaxic registration framework

  • Offset translation is sensitive to stereotaxic misalignment

  • Rigid registration improves accuracy at independent internal targets

  • Affine registration can overfit skull-surface fiducials

  • Implanted screw fiducials supported in vivo stereotaxic registration

Full Text

The Full Text of this preprint is available as a PDF (2.6 MB). The Web version will be available soon.


Articles from bioRxiv are provided here courtesy of Cold Spring Harbor Laboratory Preprints

RESOURCES