Abstract
This study aimed to evaluate whether serial ultrasound measurements of antral volumes are reproducible and, if so, whether they are representative of the entire gastric contents and reliably measure gastric emptying. The antral volume was measured in man after oral and intragastric administration of known amounts of 5% glucose solutions, and on two separate occasions in the same subjects, after the ingestion of a standardised solid-liquid meal (1050 kcal). Antral volume measurements were performed in both supine and upright positions; inter- and intraobserver measurement errors were also assessed. After ingestion or intragastric administration of equal amounts of liquid, antral volumes determined by ultrasound showed a wide intersubject variability. In each individual subject, however, a linear trend was found between the antral volume and amount of ingested or administered liquid. Intrasubject variability of antral volume measurements was at its minimum in fasting conditions and 300 minutes after ingestion of the solid-liquid meal. Intra- and interobserver variations and whether the patient was erect or supine did not affect measurements of antral volumes. These results support the use of real time ultrasound in determining the gastric emptying time. Results at fasting and 300 minutes after a solid-liquid meal are stable end points of measurement.
Full text
PDFImages in this article
Selected References
These references are in PubMed. This may not be the complete list of references from this article.
- Bolondi L., Bortolotti M., Santi V., Calletti T., Gaiani S., Labò G. Measurement of gastric emptying time by real-time ultrasonography. Gastroenterology. 1985 Oct;89(4):752–759. doi: 10.1016/0016-5085(85)90569-4. [DOI] [PubMed] [Google Scholar]
- Brophy C. M., Moore J. G., Christian P. E., Egger M. J., Taylor A. T. Variability of gastric emptying measurements in man employing standardized radiolabeled meals. Dig Dis Sci. 1986 Aug;31(8):799–806. doi: 10.1007/BF01296046. [DOI] [PubMed] [Google Scholar]
- Holt S., Cervantes J., Wilkinson A. A., Wallace J. H. Measurement of gastric emptying rate in humans by real-time ultrasound. Gastroenterology. 1986 Apr;90(4):918–923. doi: 10.1016/0016-5085(86)90868-1. [DOI] [PubMed] [Google Scholar]
- Holt S., McDicken W. N., Anderson T., Stewart I. C., Heading R. C. Dynamic imaging of the stomach by real-time ultrasound--a method for the study of gastric motility. Gut. 1980 Jul;21(7):597–601. doi: 10.1136/gut.21.7.597. [DOI] [PMC free article] [PubMed] [Google Scholar]
- King P. M., Adam R. D., Pryde A., McDicken W. N., Heading R. C. Relationships of human antroduodenal motility and transpyloric fluid movement: non-invasive observations with real-time ultrasound. Gut. 1984 Dec;25(12):1384–1391. doi: 10.1136/gut.25.12.1384. [DOI] [PMC free article] [PubMed] [Google Scholar]