Purpose

To evaluate the in vivo efficacy of bone morphogenetic protein 9 (BMP9) relative to bone morphogenetic protein 2 (BMP2) in a beagle peri-implant critical-size defect model.

Methods

Peri-implant defects were created in beagle dogs and treated with either a collagen sponge (CS) or deproteinized bovine bone mineral with collagen (OCS-B Xenomatrix collagen [OCS-BC]), with or without BMP2 or BMP9. After 8 weeks, bone regeneration and osseointegration were evaluated using radiographic, histological, and biomechanical analyses.

Results

Radiographic analysis demonstrated that BMP treatment significantly increased peri-implant mineralization, with bone mineral density increasing from 0.597±0.151 (control) to 0.896±0.173 in the CS+BMP9 group (P<0.0001). Histological and histomorphometric analyses corroborated these findings, showing greater new bone formation and higher bone-to-implant contact (BIC) (7.943±7.048 vs. 68.90±20.27 in the CS+BMP9 group; P<0.05) without overt inflammatory reactions. Region-of-interest (ROI)-based micro-computed tomography analysis (200 μm) and resonance frequency analysis further supported improved osseointegration and stability, with osseointegration increasing from 20.32±6.976 to 70.37±0.785 in the CS+BMP9 group (P<0.0001) and the implant stability quotient (ISQ) peaking at 70.92±3.523 in the OCS-BC+BMP9 group (P<0.0001). Two-way analysis of variance indicated scaffold-dependent magnitudes for bulk endpoints, whereas interaction terms were not significant for BIC, ROI-based osseointegration, or ISQ, supporting preservation of BMP9-associated benefits across scaffold types for these outcomes.

Conclusions

BMP9 produced overall improvements comparable to BMP2 and may provide more reproducible osseointegration-related outcomes across scaffold types.

Keywords: Bone morphogenetic protein 2, Bone regeneration, Dental implants, Growth differentiation factor 2, Osseointegration

Graphical Abstract

graphic file with name jpis-56-417-abf001.webp

INTRODUCTION

Peri-implant defects compromise stable osseointegration [1]; therefore, predictable bone regeneration and rapid implant-bone anchorage remain central clinical objectives. Recent consensus reports and reviews highlight variable regenerative outcomes associated with peri-implant bone loss [2], reinforcing the need for biomaterials and biologics that reliably restore hard tissue and accelerate re-osseointegration. The success of implant-supported restorations is evaluated according to comprehensive success criteria and validated esthetic assessment systems [3], ensuring both functional stability and peri-implant soft-tissue harmony.

Bone morphogenetic protein 2 (BMP2) is widely used as a reference osteoinductive growth factor for oral and maxillofacial bone regeneration [4]. However, its clinical utility is limited by adverse effects, including postoperative inflammation, ectopic bone formation, osteoclast-mediated bone resorption, and inappropriate adipogenesis [5]. These complications contribute to inconsistent local efficacy and safety signals and have motivated the development of more efficient and safer osteoinductive strategies.

Accordingly, current research focuses on delivery systems designed to reduce burst release and lower the effective dose [6,7], as well as on alternative osteogenic cues that may match or surpass BMP2 activity while offering improved handling and safety profiles. Emerging evidence suggests that alternative morphogens, such as bone morphogenetic protein 9 (BMP9), exhibit robust osteogenic signaling and strong osteogenic potency in preclinical models, highlighting a potential strategy for achieving more predictable peri-implant bone regeneration and faster, safer osseointegration.

At the molecular level, BMP9 engages canonical BMP/Smad signaling more potently than BMP2 [8,9] and increases the expression of key osteogenic transcription factors, including runt-related transcription factor 2 (Runx2) [10]. BMP9 also enhances Wnt/β-catenin signaling, increasing β-catenin levels and accelerating bone repair [11]. Although BMP2 modulates both osteoblast and osteoclast dynamics [12,13], BMP9 appears to act predominantly along the osteogenic axis. In mesenchymal stem cells, BMP9 increases alkaline phosphatase (ALP) activity, promotes mineralized nodule formation, and upregulates osteogenic markers such as type I collagen (Col1), Runx2, ALP, and osteocalcin [14,15]. Collectively, these findings support BMP9 as a promising candidate for therapeutic bone regeneration.

Although BMP9 has been reported to be effective at lower doses than BMP2 in some experimental settings, the minimal effective dose and optimal dosing regimen of BMP9 have not been established in large-animal peri-implant critical-size defect models. In addition, direct comparative data evaluating BMP9 and BMP2 under identical experimental conditions using clinically relevant carriers, such as collagen sponge (CS) and deproteinized bovine bone mineral (DBBM), remain limited. Therefore, this study compared the effects of BMP9 and BMP2 on bone formation and osseointegration in a beagle peri-implant critical-size defect model while simultaneously examining the carrier effects of CS and DBBM on BMP efficacy.

MATERIALS AND METHODS

Animals

Fourteen male beagle dogs (age, 7–9 months; weight, 10–15 kg) with complete dentition and healthy periodontium were used. The animals were housed individually and monitored daily by veterinarians. This study followed the modified Animal Research: Reporting of In Vivo Experiments guidelines for preclinical research. All protocols were approved by the Institutional Animal Care and Use Committee of Seoul National University, Korea (approval No. SNU-220914-6).

Materials for in vivo experiments

A total of 56 titanium sandblasted, large-grit, acid-etched (SLA) surface implants (ø 3.3×8.0 mm; bone-level tapered implant, SLActive, Roxolid, Straumann AG, Basel, Switzerland), CS (Straumann Regenomer, NIBEC, Jincheon, Korea), and DBBM with 10% porcine Col1 (OCS-B Xenomatrix collagen [OCS-BC; Straumann XenoFlex]; NIBEC, Seoul, Korea) were used. The peri-implant defects were covered with a collagen membrane (BioGide; Geistlich Biomaterials, Wolhusen, Switzerland) [16].

Surgical procedure

The preclinical experimental procedure is shown in Figure 1A. General anesthesia was induced by intravenous injection of tiletamine hydrochloride/zolazepam hydrochloride (Zoletil 50; Virbac, Carros, France) and xylazine hydrochloride (Rompun; Bayer, Seoul, Korea). Bilateral mandibular premolars (P2, P3, and P4) were extracted, and the extraction sites healed uneventfully (Figure 1B). Twelve weeks after extraction, 2 box-shaped defects were created in the healed areas, and implants were placed at the center of each defect (Figure 1C). Each dog had 4 mandibular defects that were treated with different materials, as follows:

Figure 1. Experimental scheme and surgical procedures. (A) Study flowchart and group allocation. Bilateral mandibular premolars (P2, P3, and P4) were extracted 12 weeks prior to surgery. In each surgery, 2 box-shaped alveolar defects were created in the post-extraction regions of the mandible, and 1 implant was placed at the center of each defect. The peri-implant defects were allocated into the following groups: Control, CS, CS+BMP2, CS+BMP9, OCS-BC, and OCS-BC+BMP2, and OCS-BC+BMP9. Implant stability testing and micro-CT were performed 8 weeks after surgery. (B) The procedures for tooth extraction and healing are shown. (a) Pre-extraction; (b) tooth extraction of P2, P3, and P4, and suturing; (c) 1 week after extraction; and (d) 10 weeks after extraction. (C) Surgical procedures and defect schemes are shown. (a) Preoperative; (b) defect creation after flap elevation; (c) dental implant insertion; (d) defect scheme; (e) graft material insertion at the peri-implant site; (f) collagen membrane coverage, and (g) flap suturing.

Figure 1

CS: collagen sponge, BMP2: bone morphogenetic protein 2, BMP9: bone morphogenetic protein 9, OCS-BC: OCS-B collagen, CT: computed tomography, ISQ: implant stability quotient.

  • • Control group (n=8): empty defects (sham surgery)

  • • CS group (n=8): CS alone

  • • CS+BMP2 group (n=8): CS + 150 μg recombinant human [rh]-BMP2 (1.5 mg/mL, 100 μL)

  • • CS+BMP9 group (n=8): CS + 150 μg rh-BMP9 (1.5 mg/mL, 100 μL)

  • • OCS-BC group (n=8): OCS-BC alone

  • • OCS-BC+BMP2 group (n=8): OCS-BC + 150 μg rh-BMP2 (1.5 mg/mL, 100 μL)

  • • OCS-BC+BMP9 group (n=8): OCS-BC + 150 μg rh-BMP9 (1.5 mg/mL, 100 μL)

Thus, the total dose per defect was 150 μg for each BMP, with 100 μL of a 1.5-mg/mL solution loaded onto the carrier. Primary wound closure was achieved with 5-0 Ethilon (Ethicon, Johnson & Johnson International, New Brunswick, NJ, USA) using mattress and interrupted sutures. Antibiotics were administered for 5 days postoperatively, and the sutures were removed after 2 weeks. All animals were euthanized 8 weeks after surgery by intravenous injection of potassium chloride (2 mL/kg). The mandibles were block resected and fixed in 4% paraformaldehyde solution for 14 days.

Radiographic analyses

All samples were scanned by micro-computed tomography (micro-CT) using a SkyScan 1273 device (Bruker, Kontich, Belgium). Two cubic volumes of interest (VOIs), each measuring 3×3×3 mm3, were defined for each sample to analyze bone mineral density (BMD) and bone volume fraction (BV/TV). Image reconstruction was performed using NRecon (Bruker Micro-CT, Bruker AXS, Madison, WI, USA), and all quantitative assessments were performed using CTAn software (Bruker Micro-CT) (Figure 2). Cross-sectional images were visualized using DataViewer (Bruker Micro-CT) to confirm scan integrity and accurately locate the VOIs.

Figure 2. Micro-CT analyses. (A) Representative 3-dimensional reconstructed micro-CT images are shown for the (a) control, (b) CS, (c) CS+BMP2, (d) CS+BMP9, (e) OCS-BC, (f) OCS-BC+BMP2, and (g) OCS-BC+BMP9 groups. (B) Two-dimensional sagittal micro-CT images are shown for the (a) control, (b) CS, (c) CS+BMP2, (d) CS+BMP9, (e) OCS-BC, (f) OCS-BC+BMP2, and (g) OCS-BC+BMP9 groups. (C) Quantification of BMD is presented as a grouped bar graph comparing 2 scaffold types (CS and OCS-BC) across the following 4 growth factor conditions: control, NT, BMP2, and BMP9. NT indicates scaffold only (no growth factor). The BMP-treated groups (BMP2 and BMP9) exhibited significantly higher BMD values than the control group for both scaffold types. (D) Quantification of BV/TV is presented as a grouped bar graph. Similar to the BMD results, both BMP2 and BMP9 significantly increased BV/TV relative to the control group. Data are presented as mean ± standard deviation. Statistical significance was determined by 2-way analysis of variance followed by Tukey’s multiple-comparisons test.

Figure 2

CT: computed tomography, CS: collagen sponge, BMP2: bone morphogenetic protein 2, BMP9: bone morphogenetic protein 9, OCS-BC: OCS-B collagen, NT: not treated, BMD: bone mineral density, BV/TV: bone volume fraction.

Asterisks (*) indicate a significant difference compared with the control group within the same scaffold type (****P<0.0001). The hash symbol (#) indicates a statistically significant difference between the CS and OCS-BC groups within the same growth factor condition (##P<0.01, ####P<0.0001).

Histological analyses

All specimens were processed using Technovit 7200 VLC resin (Kulzer GmbH, Hanau, Germany) according to the manufacturer's guidelines. Samples were progressively dehydrated in a graded ethanol series, and the resin was infiltrated into both the implant and the surrounding tissues before polymerization under ultraviolet light. The polymerized blocks were sectioned using an Exakt cutting system (Exakt Apparatebau GmbH, Norderstedt, Germany) fitted with a diamond blade. Section thickness was initially set at approximately 100–300 μm. Each section was then ground and polished using the Exakt grinding system to a final thickness of approximately 80 μm. Staining was performed using multiple staining solutions (Polysciences, Warrington, PA, USA) to enhance tissue contrast.

To assess newly formed bone in direct contact with the implant surface, resin-embedded sections stained with hematoxylin and eosin (H&E) were qualitatively examined under light microscopy at ×100 magnification.

For histological evaluation, 2 regions of interest (ROIs) were defined for each implant on the mesial and distal sides (Figure 3A). Each ROI encompassed a cross-sectional area of the bone defect and measured approximately 3 mm in width (horizontal) and 4 mm in height (vertical). For percent area analysis, stained sections were photographed and analyzed using Image-Pro Plus v10.0 (Media Cybernetics, Rockville, MD, USA). Within each ROI, the total area and the area occupied by newly formed bone were quantified, and new bone formation was expressed as a percentage of the total ROI area [17]. To assess bone-to-implant contact (BIC), a 4-mm vertical segment along the implant surface was designated as the reference length. Within this segment, the length of the implant surface in direct contact with newly formed bone was measured [18]. BIC was calculated as the ratio of this contact length to the total reference length and expressed as a percentage. This dual assessment of the mesial and distal regions provides a comprehensive evaluation of peri-implant bone healing and osseointegration [19].

Figure 3. Histological analyses. (A) Representative histological sections stained with hematoxylin and eosin are shown for the (a) control, (b) CS, (c) CS+BMP2, (d) CS+BMP9, (e) OCS-BC, (f) OCS-BC+BMP2, and (g) OCS-BC+BMP9 groups. The upper images are shown at ×40 magnification, and the lower images are shown at ×100 magnification in the peri-implant region. When BMP9 or BMP2 was loaded into either the CS or OCS-BC scaffold, new bone formation was evident. However, in the OCS-BC+BMP9 and OCS-BC+BMP2 groups, some OCS-B particles were embedded within newly formed bone. (B) The percent area of new bone formation is presented as a grouped bar graph comparing 2 scaffold types (CS and OCS-BC) across the following growth factor conditions: control, NT, BMP2, and BMP9. NT indicates scaffold only (no growth factor). The BMP-treated groups showed a significant increase in the percentage of new bone area compared with the control group. (C) BIC values are presented as a grouped bar graph. Both the BMP2 and BMP9 groups showed significantly higher BIC percentages than the control group. Data are presented as mean ± standard deviation. Statistical significance was determined by 2-way analysis of variance followed by Tukey’s multiple-comparisons test.

Figure 3

CS: collagen sponge, BMP2: bone morphogenetic protein 2, BMP9: bone morphogenetic protein 9, OCS-BC: OCS-B collagen, NT: not treated, BIC: bone-to-implant contact.

Asterisks (*) indicate a significant difference compared with the control group within the same scaffold type (***P<0.001, ****P<0.0001). The hash symbol (#) indicates a statistically significant difference between the CS and OCS-BC groups within the same growth factor condition (#P<0.1, ##P<0.01, ###P<0.001).

The evaluation of osseointegration

For osseointegration analysis on micro-CT images [20], the ROI was delineated as a 200-μm zone immediately surrounding the implant surface (Figure 4A). Implant stability was assessed by resonance frequency analysis using an Osstell device (Osstell AB, Gothenburg, Sweden). Measurements were obtained in 2 perpendicular planes (buccolingual and mesiodistal) for each implant, and the implant stability quotient (ISQ) values from both directions were averaged.

Figure 4. Osseointegration analysis. (A) Representative 2-dimensional coronal micro-computed tomography images. (B) Quantitative osseointegration rates (%) are presented as a grouped bar graph comparing 2 scaffold types (CS and OCS-BC) across the following 4 growth factor conditions: Control, NT, BMP2, and BMP9. NT indicates scaffold-only (no growth factor). The BMP-treated groups (BMP2 and BMP9) showed significantly higher osseointegration rates than the control group for both scaffold types. (C) Resonance frequency analysis values (ISQ) are presented as a grouped bar graph. Implant stability, assessed via the ISQ, was significantly better in both the BMP2 and BMP9 groups than in the control group. Data are presented as mean ± standard deviation. Statistical significance was determined by 2-way analysis of variance followed by Tukey’s multiple-comparisons test.

Figure 4

CS: collagen sponge, OCS-BC: OCS-B collagen, NT: not treated, BMP2: bone morphogenetic protein 2, BMP9: bone morphogenetic protein 9, ISQ: implant stability quotient.

Asterisks (*) indicate a significant difference compared to the control group for the same scaffold type (*P<0.1, **P<0.01, ****P<0.0001). No hash symbols (#) are displayed in panels B and C, as the differences between the CS and OCS-BC groups in each growth factor condition were not statistically significant as assessed using Tukey’s post hoc test.

Statistical analysis

Data are presented as mean ± standard deviation. Statistical analyses were performed using GraphPad Prism 7 software (GraphPad Inc., San Diego, CA, USA). To evaluate the effects of 2 independent variables-growth factor condition (control, BMP2, and BMP9) and scaffold type (CS and OCS-BC)-and their interaction, 2-way analysis of variance (ANOVA) was performed. Tukey’s multiple-comparisons test was subsequently used for post hoc pairwise comparisons. Statistical significance was defined as P<0.05. In the figures, asterisks indicate significant differences compared with the control group within the same scaffold type (*: P<0.05, **: P<0.01, ***: P<0.001, and ****: P<0.0001). In addition, the hash symbol (#) denotes a statistically significant difference between the CS and OCS-BC groups within the same growth factor condition.

RESULTS

BMP2/9 markedly improved peri-implant bone density and volume on micro-CT

A preclinical study was conducted using a beagle model of peri-implant defects, as shown in Figure 1. On micro-CT analysis (Figure 2), the BMP2- and BMP9-treated groups showed visibly greater radiopacity than the control, CS, and OCS-BC groups in both 3-dimensional reconstructed images (Figure 2A) and 2-dimensional sagittal images (Figure 2B). Quantitative analysis showed that BMD was significantly higher in the CS+BMP2 group (0.898±0.093 vs. 0.597±0.151, P<0.0001) and the CS+BMP9 group (0.896±0.173 vs. 0.597±0.151, P<0.0001) than in the control group (Figure 2C, Supplementary Tables 1 and 2), and that BV/TV was significantly higher in the CS+BMP2 group (71.67±10.28 vs. 41.70±10.45, P<0.0001) and the CS+BMP9 group (71.13±11.02 vs. 41.70±10.45, P<0.0001) than in the control group (Figure 2D, Supplementary Tables 1 and 3). Notably, the CS+BMP2 and CS+BMP9 groups exhibited the highest BMD and BV/TV values among all groups (P<0.0001). Consistent with Figure 2C and D, these effect sizes indicate that BMP treatment substantially increased mineral density and BV/TV relative to the control condition. To directly evaluate whether the growth factor effects differed by scaffold type, we performed 2-way ANOVA (growth factor × scaffold) including the interaction term. Significant interactions were observed for BMD and BV/TV, indicating scaffold-dependent differences for these micro-CT endpoints (Figure 2C and D, Supplementary Table 4).

BMP2/9 increased peri-implant new bone area and BIC on histomorphometry

Histological analysis revealed increased new bone formation in the BMP2- and BMP9-treated groups (Figure 3). Qualitatively, sections showed denser peri-implant bone tissue in the BMP-treated groups, with particularly prominent bone accumulation around the implant surfaces in the CS+BMP9 and OCS-BC+BMP9 groups (Figure 3A). Morphologically, compared with untreated conditions, the BMP-treated groups more frequently displayed continuous bone-tissue bridging toward the implant surface and a more mature-appearing trabecular organization. In the OCS-BC groups, newly formed bone was often observed interspersed among graft particles, suggesting concurrent graft-associated remodeling and peri-implant bone formation. Importantly, within evaluable soft-tissue regions not yet replaced by bone, no prominent inflammatory cell aggregates or obvious inflammatory infiltration were observed, and no clear bone extension into soft tissues was identified, supporting the absence of overt adverse local tissue reactions in the examined sections.

Quantitatively, the percent area of new bone formation (Figure 3B) and BIC (Figure 3C) were significantly higher in the BMP-treated groups. The percent new bone area was significantly higher in the CS+BMP2 group (79.25±11.81 vs. 14.10±7.185, P<0.0001), CS+BMP9 group (80.42±7.215 vs. 14.10±7.185, P<0.0001), OCS-BC+BMP2 group (49.63±11.31 vs. 14.10±7.185, P<0.0001), and OCS-BC+BMP9 group (57.55±14.17 vs. 14.10±7.185, P<0.0001) than in the control group (Figure 3B, Supplementary Tables 1 and 5). Likewise, BIC was significantly higher in the CS+BMP2 group (65.74±27.67 vs. 7.943±7.048, P<0.0001), CS+BMP9 group (68.90±20.27 vs. 7.943±7.048, P<0.0001), and OCS-BC+BMP9 group (59.84±11.96 vs. 7.943±7.048, P<0.001) than in the control group (Figure 3C, Supplementary Tables 1 and 6). Thus, histomorphometry not only confirmed greater mineralized tissue formation, consistent with the micro-CT findings, but also demonstrated that this mineralized tissue translated into greater direct BIC and increased new bone occupancy within the defect region.

Two-way ANOVA showed a significant interaction for percent new bone area, indicating scaffold-dependent differences in the magnitude of the histomorphometric response. In contrast, the interaction term was not significant for BIC, suggesting that the overall BMP-associated improvement in BIC was maintained across scaffold types, even when the absolute gains in new bone area varied by scaffold (Supplementary Table 4).

BMP benefits for ROI osseointegration and ISQ were preserved regardless of scaffold type

To evaluate peri-implant osseointegration, a 200-μm-wide ROI surrounding the implant surface was delineated on micro-CT images (Figure 4A). The BMP-treated groups showed significantly higher values than the control group (Figure 4B), indicating that the micro-CT and histological findings were accompanied by improved mineralized tissue presence in the immediate implant-adjacent zone.

Osseointegration was significantly higher in the CS+BMP2 group (61.90±7.397 vs. 20.32±6.976, P<0.0001), CS+BMP9 group (70.37±0.785 vs. 20.32±6.976, P<0.0001), OCS-BC+BMP2 group (56.11±6.243 vs. 20.32±6.976, P<0.0001), and OCS-BC+BMP9 group (61.81±2.951 vs. 20.32±6.976, P<0.0001) than in the control group (Figure 4B, Supplementary Tables 1 and 7).

Resonance frequency analysis showed that the ISQ value was significantly higher in the BMP-treated groups than in the control group (P<0.0001; Figure 4C), with the highest value observed in the OCS-BC+BMP9 group (70.92±3.523; Supplementary Tables 1 and 8). Together, these data indicate that BMP-associated improvements in peri-implant bone formation and interface contact were accompanied by meaningful gains in stability-related outcomes.

For ROI-based osseointegration and ISQ, the interaction term was not significant, indicating that the beneficial effects were preserved across scaffold types for these measures, even though selected micro-CT and histomorphometric endpoints showed scaffold-dependent differences in magnitude (Supplementary Table 4).

DISCUSSION

To investigate whether the reported osteoinductive capacity of BMP9 translates into improved bone regeneration in vivo, we conducted a preclinical study using a beagle peri-implant defect model. Both BMP2 and BMP9 significantly improved peri-implant regeneration and stability relative to the control condition, as reflected by higher micro-CT BMD and BV/TV values, greater histomorphometric new bone area and BIC, and increased 200-μm ROI-based osseointegration and ISQ. Importantly, BMP9 generally produced improvements comparable to those of BMP2, with numerically favorable trends in selected measures but without consistent statistical superiority within the same scaffold type.

Qualitative inspection of the micro-CT reconstructions suggested differences in trabecular appearance between the growth factors, with BMP9-treated sites often appearing more consolidated and interconnected, whereas BMP2-treated sites more frequently showed a porous, honeycomb-like pattern, as previously reported [21]. These impressions should be interpreted cautiously because microarchitectural indices (e.g., connectivity density or porosity) were not primary quantitative endpoints in the present analysis. Nonetheless, they are consistent with previous reports that BMP2 can promote osteoclastogenesis and remodeling, potentially contributing to a more porous trabecular pattern under certain conditions [12]. In our study, stability-related outcomes supported the interpretation that BMP9-treated implants achieved at least comparable stability and, under some conditions, numerically greater stability than BMP2-treated implants.

The degree of scaffold dependence differed by endpoint. Two-way ANOVA revealed significant interaction effects for micro-CT and histomorphometric measures, including BMD, BV/TV, and percent new bone area, indicating that the magnitude of the growth factor effect varied by scaffold type for these endpoints. In contrast, no significant interaction was observed for clinically relevant outcomes such as BIC, ROI-based osseointegration, and ISQ, supporting the interpretation that BMP9-associated improvements in peri-implant integration and stability were largely preserved across scaffolds. Consistently, post hoc comparisons suggested that scaffold-dependent differences were more pronounced with BMP2, whereas BMP9 exhibited a comparatively uniform pattern across scaffold conditions.

This endpoint-specific profile may indicate that scaffold properties exert a greater influence on bulk mineralized tissue accrual and trabecular organization, through space maintenance and factor retention, than on stabilization of the immediate bone-implant interface. Further mechanistic confirmation will require dedicated analyses of local factor availability and release kinetics. The comparatively consistent efficacy of BMP9 across scaffolds, particularly for osseointegration-relevant endpoints, may be related to its receptor engagement [9,22], enhanced stability, and activation of both Smad-dependent and non-Smad signaling pathways [11,23].

In contrast, BMP2 often requires collagen-based carriers for sustained release and protection from proteolysis [24], whereas the potent biological activity of BMP9 may account for its strong osteogenic effects [25] even in the absence of a carrier. Importantly, our findings do not establish universal scaffold independence; rather, they indicate that BMP9-driven gains in integration- and stability-related outcomes were maintained across the scaffold types evaluated here, which has practical relevance when early stability and predictable integration are prioritized. One plausible interpretation is that bulk bone accrual is scaffold-modulated, whereas implant-adjacent stabilization is achieved once osteogenic signaling exceeds a local threshold within the peri-implant microenvironment.

Although micro-CT provides valuable 3-dimensional, non-destructive visualization of peri-implant bone morphology, particularly for quantifying trabecular bone volume and architecture [26], it has inherent limitations in accurately assessing BIC, especially in the presence of bone graft particles [27]. When the scaffold consisted of CS, histological BIC measurements and micro-CT-based assessments of osseointegration yielded comparable results. However, with DBBM scaffolds, micro-CT analyses revealed similar levels of osseointegration in the OCS-BC+BMP2 and OCS-BC+BMP9 groups, whereas histological BIC measurements showed a notable difference between the 2 groups in the present study. Imaging artifacts, including beam hardening, limited spatial resolution, and overlapping radiodensities between graft materials and newly formed bone, can obscure the true implant interface or create false impressions of osseointegration, potentially leading to overestimation of BIC. In contrast, histological analysis, although destructive and limited to selected sections, provides high-resolution, 2-dimensional imaging that enables precise and direct evaluation of BIC [28,29]. Thus, micro-CT and histology provide complementary insights into peri-implant bone healing.

Despite these promising findings, the present study has several limitations. First, qualitative examination of the H&E-stained sections did not reveal prominent aggregates of inflammatory cells, marked inflammatory infiltration, or clear evidence of bone extension into adjacent soft tissues around the implant. However, comprehensive assessment remained limited: inflammation was not systematically graded, immune cell subsets were not characterized, and potential ectopic bone formation could not be rigorously evaluated because of section-related constraints and the lack of specific immunohistochemical markers. Second, the observation period was limited to 8 weeks; thus, the long-term stability, remodeling dynamics, and safety profile of BMP9 remain to be determined. Third, although this study focused on BMP/Smad and Wnt/β-catenin pathways, other signaling mechanisms involved in angiogenesis or immune modulation were not explored and may also contribute to BMP9-mediated bone regeneration. Fourth, BMP2 and BMP9 were administered at the same mass dose (150 μg) to enable a controlled comparison within our factorial design; however, this does not necessarily reflect equipotent dosing between the 2 proteins. Therefore, the present comparisons should be interpreted within the tested dosing condition, and future studies should include dose-response and/or equipotent-dose evaluations to determine the optimal dose for each BMP.

Within these limitations, the present study demonstrates that BMP9 significantly enhances osteogenic differentiation and peri-implant bone formation, yielding outcomes comparable to those of BMP2 and, for some measures, numerically favorable under the tested in vivo conditions.

Footnotes

Funding: This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF), funded by the Ministry of Education (2021R1A6A1A03039462, RS-2024-00349549), and Creative-Pioneering Researchers Program through Seoul National University. The dental implants (BLT SLActive, Roxolid) were provided by Straumann AG for this study.

Conflict of Interest: No potential conflict of interest relevant to this article was reported.

Author Contributions:
  • Conceptualization: Sungtae Kim, Jue Yeon Lee, Yoon Jeong Park, Chong Pyung Chung, and Young-Dan Cho.
  • Formal analysis: Hee-Seung Han, Dong Woo Lee.
  • Investigation: Hee-Seung Han, Dong Woo Lee.
  • Methodology: Sungtae Kim, Jue Yeon Lee, Yoon Jeong Park, Chong Pyung Chung, Young-Dan Cho.
  • Project administration: Yoon Jeong Park, Chong Pyung Chung, Young-Dan Cho.
  • Writing - original draft: Hee-Seung Han, Dong Woo Lee.
  • Writing - review & editing: Sungtae Kim, Jue Yeon Lee, Yoon Jeong Park, Chong Pyung Chung, Young-Dan Cho.

SUPPLEMENTARY MATERIALS

Supplementary Table 1

BMD, BV/TV, percent area of new bone formation (%), BIC (%) values, osteointegration rate (%), and ISQ values

jpis-56-417-s001.xls (25.5KB, xls)
Supplementary Table 2

Post-hoc pairwise comparisons of bone mineral density using Tukey’s multiple comparisons test

jpis-56-417-s002.xls (27KB, xls)
Supplementary Table 3

Post-hoc pairwise comparisons of bone volume fraction using Tukey’s multiple comparisons test

jpis-56-417-s003.xls (26.5KB, xls)
Supplementary Table 4

Two-way analysis of variance results (growth factor × scaffold) of BMD, BV/TV, percent area of new bone formation (%), BIC (%) values, osteointegration rate (%), and ISQ

jpis-56-417-s004.xls (26KB, xls)
Supplementary Table 5

Post-hoc pairwise comparisons of percent area of new bone formation using Tukey’s multiple comparisons test

jpis-56-417-s005.xls (27KB, xls)
Supplementary Table 6

Post-hoc pairwise comparisons of bone-to-implant contact using Tukey’s multiple comparisons test

jpis-56-417-s006.xls (27KB, xls)
Supplementary Table 7

Post-hoc pairwise comparisons of osteointegration using Tukey’s multiple comparisons test

jpis-56-417-s007.xls (26.5KB, xls)
Supplementary Table 8

Post-hoc pairwise comparisons of implant stability quotient using Tukey’s multiple comparisons test

jpis-56-417-s008.xls (26.5KB, xls)

References

  • 1.Schwarz F, Sahm N, Schwarz K, Becker J. Impact of defect configuration on the clinical outcome following surgical regenerative therapy of peri-implantitis. J Clin Periodontol. 2010;37:449–455. doi: 10.1111/j.1600-051X.2010.01540.x. [DOI] [PubMed] [Google Scholar]
  • 2.Mordini L, Sun N, Chang N, De Guzman JP, Generali L, Consolo U. Peri-implantitis regenerative therapy: a review. Biology (Basel) 2021;10 doi: 10.3390/biology10080773. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Cosyn J, Thoma DS, Hämmerle CH, De Bruyn H. Esthetic assessments in implant dentistry: objective and subjective criteria for clinicians and patients. Periodontol 2000. 2017;73:193–202. doi: 10.1111/prd.12163. [DOI] [PubMed] [Google Scholar]
  • 4.On SW, Park SY, Yi SM, Park IY, Byun SH, Yang BE. Current status of recombinant human bone morphogenetic protein-2 (rhBMP-2) in maxillofacial surgery: should it be continued? Bioengineering (Basel) 2023;10:1005. doi: 10.3390/bioengineering10091005. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.James AW, LaChaud G, Shen J, Asatrian G, Nguyen V, Zhang X, et al. A review of the clinical side effects of bone morphogenetic protein-2. Tissue Eng Part B Rev. 2016;22:284–297. doi: 10.1089/ten.teb.2015.0357. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Kong D, Shi Y, Gao Y, Fu M, Kong S, Lin G. Preparation of BMP-2 loaded MPEG-PCL microspheres and evaluation of their bone repair properties. Biomed Pharmacother. 2020;130:110516. doi: 10.1016/j.biopha.2020.110516. [DOI] [PubMed] [Google Scholar]
  • 7.Qi J, Wu H, Liu G. Novel strategies for spatiotemporal and controlled BMP-2 delivery in bone tissue engineering. Cell Transplant. 2024;33:9636897241276733. doi: 10.1177/09636897241276733. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Chen L, Zou X, Zhang RX, Pi CJ, Wu N, Yin LJ, et al. IGF1 potentiates BMP9-induced osteogenic differentiation in mesenchymal stem cells through the enhancement of BMP/Smad signaling. BMB Rep. 2016;49:122–127. doi: 10.5483/BMBRep.2016.49.2.228. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Upton PD, Davies RJ, Trembath RC, Morrell NW. Bone morphogenetic protein (BMP) and activin type II receptors balance BMP9 signals mediated by activin receptor-like kinase-1 in human pulmonary artery endothelial cells. J Biol Chem. 2009;284:15794–15804. doi: 10.1074/jbc.M109.002881. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Zhang L, Luo Q, Shu Y, Zeng Z, Huang B, Feng Y, et al. Transcriptomic landscape regulated by the 14 types of bone morphogenetic proteins (BMPs) in lineage commitment and differentiation of mesenchymal stem cells (MSCs) Genes Dis. 2019;6:258–275. doi: 10.1016/j.gendis.2019.03.008. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Tang N, Song WX, Luo J, Luo X, Chen J, Sharff KA, et al. BMP-9-induced osteogenic differentiation of mesenchymal progenitors requires functional canonical Wnt/beta-catenin signalling. J Cell Mol Med. 2009;13:2448–2464. doi: 10.1111/j.1582-4934.2008.00569.x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Bordukalo-Nikšić T, Kufner V, Vukičević S. The role of BMPs in the regulation of osteoclasts resorption and bone remodeling: from experimental models to clinical applications. Front Immunol. 2022;13:869422. doi: 10.3389/fimmu.2022.869422. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Song T, Huang D, Song D. The potential regulatory role of BMP9 in inflammatory responses. Genes Dis. 2022;9:1566–1578. doi: 10.1016/j.gendis.2021.08.010. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 14.Luu HH, Song WX, Luo X, Manning D, Luo J, Deng ZL, et al. Distinct roles of bone morphogenetic proteins in osteogenic differentiation of mesenchymal stem cells. J Orthop Res. 2007;25:665–677. doi: 10.1002/jor.20359. [DOI] [PubMed] [Google Scholar]
  • 15.Wang J, Zhang H, Zhang W, Huang E, Wang N, Wu N, et al. Bone morphogenetic protein-9 effectively induces osteo/odontoblastic differentiation of the reversibly immortalized stem cells of dental apical papilla. Stem Cells Dev. 2014;23:1405–1416. doi: 10.1089/scd.2013.0580. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Lee DW, Han HS, Kim YB, Seok S, Kim S, Lee JY, et al. Longitudinal comparative study on osteogenic capacity using two collagenated xenografts in artificial bone defects in beagles. Sci Rep. 2025;15:10408. doi: 10.1038/s41598-025-94284-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Vignoletti F, Johansson C, Albrektsson T, De Sanctis M, San Roman F, Sanz M. Early healing of implants placed into fresh extraction sockets: an experimental study in the beagle dog. De novo bone formation. J Clin Periodontol. 2009;36:265–277. doi: 10.1111/j.1600-051X.2008.01363.x. [DOI] [PubMed] [Google Scholar]
  • 18.Kang J, Shibasaki M, Terauchi M, Oshibe N, Hyodo K, Marukawa E. Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model. J Periodontal Implant Sci. 2024;54:96–107. doi: 10.5051/jpis.2204660233. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Kim DS, Kim DG, Park CJ, Cho LR. Histomorphometry and stability analysis of early loaded implants with two different surface conditions in beagle dogs. J Adv Prosthodont. 2009;1:10–18. doi: 10.4047/jap.2009.1.1.10. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Zhou P, He F, Liu B, Wei S. Nerve electrical stimulation enhances osseointegration of implants in the beagle. Sci Rep. 2019;9:4916. doi: 10.1038/s41598-019-41471-z. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 21.Khorsand B, Elangovan S, Hong L, Dewerth A, Kormann MS, Salem AK. A comparative study of the bone regenerative effect of chemically modified RNA encoding BMP-2 or BMP-9. AAPS J. 2017;19:438–446. doi: 10.1208/s12248-016-0034-8. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Salmon RM, Guo J, Wood JH, Tong Z, Beech JS, Lawera A, et al. Molecular basis of ALK1-mediated signalling by BMP9/BMP10 and their prodomain-bound forms. Nat Commun. 2020;11:1621. doi: 10.1038/s41467-020-15425-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Mostafa S, Pakvasa M, Coalson E, Zhu A, Alverdy A, Castillo H, et al. The wonders of BMP9: from mesenchymal stem cell differentiation, angiogenesis, neurogenesis, tumorigenesis, and metabolism to regenerative medicine. Genes Dis. 2019;6:201–223. doi: 10.1016/j.gendis.2019.07.003. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Arias-Betancur A, Badilla-Wenzel N, Astete-Sanhueza Á, Farfán-Beltrán N, Dias FJ. Carrier systems for bone morphogenetic proteins: an overview of biomaterials used for dentoalveolar and maxillofacial bone regeneration. Jpn Dent Sci Rev. 2022;58:316–327. doi: 10.1016/j.jdsr.2022.10.001. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Lamplot JD, Qin J, Nan G, Wang J, Liu X, Yin L, et al. BMP9 signaling in stem cell differentiation and osteogenesis. Am J Stem Cells. 2013;2:1–21. [PMC free article] [PubMed] [Google Scholar]
  • 26.Bissinger O, Probst FA, Wolff KD, Jeschke A, Weitz J, Deppe H, et al. Comparative 3D micro-CT and 2D histomorphometry analysis of dental implant osseointegration in the maxilla of minipigs. J Clin Periodontol. 2017;44:418–427. doi: 10.1111/jcpe.12693. [DOI] [PubMed] [Google Scholar]
  • 27.Schouten C, Meijer GJ, van den Beucken JJ, Spauwen PH, Jansen JA. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography. Biomaterials. 2009;30:4539–4549. doi: 10.1016/j.biomaterials.2009.05.017. [DOI] [PubMed] [Google Scholar]
  • 28.Stoppie N, van der Waerden JP, Jansen JA, Duyck J, Wevers M, Naert IE. Validation of microfocus computed tomography in the evaluation of bone implant specimens. Clin Implant Dent Relat Res. 2005;7:87–94. doi: 10.1111/j.1708-8208.2005.tb00051.x. [DOI] [PubMed] [Google Scholar]
  • 29.Bernhardt R, Kuhlisch E, Schulz MC, Eckelt U, Stadlinger B. Comparison of bone-implant contact and bone-implant volume between 2D-histological sections and 3D-SRµCT slices. Eur Cell Mater. 2012;23:237–248. doi: 10.22203/ecm.v023a18. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplementary Table 1

BMD, BV/TV, percent area of new bone formation (%), BIC (%) values, osteointegration rate (%), and ISQ values

jpis-56-417-s001.xls (25.5KB, xls)
Supplementary Table 2

Post-hoc pairwise comparisons of bone mineral density using Tukey’s multiple comparisons test

jpis-56-417-s002.xls (27KB, xls)
Supplementary Table 3

Post-hoc pairwise comparisons of bone volume fraction using Tukey’s multiple comparisons test

jpis-56-417-s003.xls (26.5KB, xls)
Supplementary Table 4

Two-way analysis of variance results (growth factor × scaffold) of BMD, BV/TV, percent area of new bone formation (%), BIC (%) values, osteointegration rate (%), and ISQ

jpis-56-417-s004.xls (26KB, xls)
Supplementary Table 5

Post-hoc pairwise comparisons of percent area of new bone formation using Tukey’s multiple comparisons test

jpis-56-417-s005.xls (27KB, xls)
Supplementary Table 6

Post-hoc pairwise comparisons of bone-to-implant contact using Tukey’s multiple comparisons test

jpis-56-417-s006.xls (27KB, xls)
Supplementary Table 7

Post-hoc pairwise comparisons of osteointegration using Tukey’s multiple comparisons test

jpis-56-417-s007.xls (26.5KB, xls)
Supplementary Table 8

Post-hoc pairwise comparisons of implant stability quotient using Tukey’s multiple comparisons test

jpis-56-417-s008.xls (26.5KB, xls)

Articles from Journal of Periodontal & Implant Science are provided here courtesy of Korean Academy of Periodontology

RESOURCES