Abstract
Background:
Interphalangeal (IP) joint fracture-dislocations are common hand injuries that can lead to joint instability, degenerative arthritis, joint stiffness, persistent pain, and decreased strength. We proposed the application of a self-designed dynamic external fixation with limited closed reduction using Kirschner wires. The objective of this study was to investigate the clinical efficacy of this technique in the treatment of IP joint fracture-dislocations of the proximal and distal IP joints.
Methods:
This retrospective study involved 44 patients who were treated for IP joint fracture-dislocations from February 2023 to November 2024. The study recorded and compared various metrics, including the Visual analog Scale (VAS) and range of motion (ROM) of the IP joint, both preoperatively and at the final follow-up.
Results:
All 44 patients were followed up after surgery for 12–23 months, with an average of (16.0 ± 3.1) months. All patients successfully completed the operation and were discharged from the hospital 3–5 days after the operation, with an average hospitalization time of (4.2 ± 0.8) days. The operative time was 30–50 minutes, with an average of (38.4 ± 5.9) minutes. During the follow-up period, all 44 patients healed successfully. One case exhibited finger joint angulation, and two cases experienced pin tract exudation. These were corrected by timely adjustment of Kirschner wires and tension, as well as anti-inflammatory treatment. No other complications, such as wire breakage, pin-tract infection, or fracture nonunion, were observed. At the final follow-up, the patients’ VAS scores were significantly lower, while the ROM values were significantly higher, and these differences were statistically significant (P < 0.05).
Conclusion:
The self-designed Kirschner wire external fixation frame combined with limited closed internal fixation for the treatment of IP joint fractures and dislocations is convenient and cost-effective; it provides reliable fixation, allows dynamic adjustment, minimizes trauma, promotes fracture healing, and facilitates the recovery of joint function. It is an ideal internal fixation method that is worthy of clinical promotion.
Keywords: fracture-dislocations, interphalangeal joint, limited closed reduction, self-designed dynamic external fixation
Introduction
Interphalangeal (IP) joint fracture-dislocations are common hand injuries, particularly among athletes, workers, and individuals engaged in high-risk activities[1,2]. Phalangeal fractures are among the most common injuries of the hand, accounting for about 19% of hand fractures[3]. According to reports in the literature, finger injuries account for 24% of hand injuries, with 49% of these finger injuries being accompanied by dislocation or subluxation[4]. Among these cases, proximal interphalangeal (PIP) joint fracture-dislocations are one of the most prevalent types[5,6]. The anatomy of the IP joint is complex, comprising the joint capsule, collateral ligaments, volar plate, and central slip of the extensor tendon, all of which play crucial roles in maintaining joint stability and function[7]. Due to the pivotal role of the IP joint in hand function, injury to this joint can lead to joint instability, degenerative arthritis, joint stiffness, persistent pain, and decreased strength[8,9].
HIGHLIGHTS
Periarticular fracture-dislocation presents a significant challenge in clinical management. Injury to the interphalangeal (IP) joint can lead to joint instability, degenerative arthritis, joint stiffness, persistent pain, and decreased strength, impairing hand function.
The key therapy for fracture-dislocation is stable reduction, ongoing maintenance, minimal trauma, a flat joint surface, and effective rehabilitation training.
Dynamic external fixation, which allows for early mobilization while maintaining joint alignment, has gained popularity but requires specialized equipment and expertise.
The self-designed Kirschner wire external fixation frame combined with limited closed internal fixation for the treatment of IP joint fractures and dislocations is convenient to obtain and cost-effective; it provides reliable fixation, allows dynamic adjustment, minimizes trauma, promotes fracture healing, and facilitates joint function recovery. It is an ideal internal fixation method and is worthy of clinical promotion.
Periarticular fracture-dislocation presents a significant challenge in clinical management[10]. Timely and effective treatment can maximize the recovery of hand mobility and function[2]. The key principles of therapy for fracture-dislocation are stable reduction, ongoing maintenance, minimal trauma, a flat joint surface, and effective rehabilitation training[11]. Common clinical treatment modalities include conservative methods, such as splinting, and surgical interventions, such as open reduction and internal fixation (ORIF), closed reduction and internal fixation (CRIF), and dynamic external fixation. Each method has its advantages and limitations. Splinting often fails to provide sufficient stability for early mobilization, leading to joint stiffness and poor functional outcomes[12]. ORIF allows for direct visualization and anatomical reduction of the joint but is associated with risks such as soft tissue scarring, infection, and prolonged recovery time[13]. On the other hand, CRIF reduces the risk of soft tissue damage but may result in inadequate reduction or fixation failure[14]. However, postoperative pain and varying degrees of IP joint stiffness are almost inevitable complications, ultimately affecting hand function and quality of life[15]. Dynamic external fixation, which allows for early mobilization while maintaining joint alignment, has gained popularity but requires specialized equipment and expertise[16].
Dynamic external fixation combined with limited CRIF has emerged as a promising strategy. Building on these principles, we propose the application of a self-designed dynamic traction external fixation frame combined with limited closed reduction using a Kirschner wire. Therefore, the objective of this study was to investigate the clinical efficacy of this technique in the treatment of IP joint fracture-dislocations, including PIP and distal interphalangeal (DIP) joints.
Methods
Subjects
This retrospective study involved 44 patients who were treated for IP joint fracture-dislocations from February 2023 to November 2024. Ethical approval was obtained from our hospital ethics committee. Informed consent was obtained from all participants involved in the study. The general patients information is shown in Table 1. The study included 36 male patients and 8 female patients, comprising 30 right hands and 14 left hands. There were 12 cases of DIP joint injury and 32 cases of PIP joint injury. The fingers involved in all subjects were 16 index fingers, 12 middle fingers, 10 ring fingers, and 6 little fingers. According to the Schenck classification[17] for IP joint fracture-dislocations, there were 16 patients with type I, 16 patients with type II, and 12 patients with type III. The participants were aged between 19 and 55 years, with a mean age of 36.8 ± 12 years. The mean body mass index recorded was 26.0 ± 3.7 kg/m2. The datasets used and analyzed during the current study are available from the corresponding author on reasonable request. The inclusion criteria were: (1) all IP joint fracture-dislocations were closed injuries within the previous 2 weeks and failed conservative treatment; (2) patients with complete case records and follow-up exceeding 3 months; and (3) no absolute contraindications to surgery, as confirmed by preoperative examination. The exclusion criteria were: (1) multiple and open injuries; (2) injury exceeding 2 weeks in duration; (3) previous surgery for old fractures or dislocations; and (4) patients lost to follow-up with incomplete follow-up data. This cohort study has been reported in line with the STROCSS guidelines[18].
Table 1.
General information of the patients.
| Variable | Study subjects (n = 44) |
|---|---|
| Age, year (mean ± SD) | 36.8 ± 12 |
| Gender | |
| Male | 36 |
| Female | 8 |
| BMI (kg/㎡) | 26.0 ± 3.7 |
| Involved side | |
| Left | 14 |
| Right | 30 |
| Involved joint | |
| DIP | 12 |
| PIP | 32 |
| Involved finger | |
| Index finger | 16 |
| Middle finger | 12 |
| Ring finger | 10 |
| Little finger | 6 |
| Schenck classification | |
| I type | 16 |
| II type | 16 |
| III type | 12 |
Surgical instruments
The procedure requires two to five Kirschner wires, with specifications including diameters of 1.0 mm, 1.2 mm, and 1.5 mm. A rubber band can be fashioned from the cuff of a sterile glove. The accompanying instruments consist of an electric drill, Kirschner wire pliers, pliers, and scissors.
Surgery
All patients were positioned supine, with the affected limb placed on the operating table. Standard disinfection and draping were performed, and a digital nerve block was administered. Prior to construction of the fixation frame, closed manual reduction or open reduction was performed for fractures or dislocations. The requirements for reduction of intra-articular fractures were as follows: no obvious step-off on the articular surface, no rotation or displacement of bone fragments involving the articular surface, and restoration of the normal curvature and alignment of the articular surface on anteroposterior and lateral fluoroscopic views, with no angular displacement in the coronal plane. For IP joint dislocations, the requirement was restoration of normal joint congruence. After reduction, a C-arm fluoroscope was used to confirm that the fractures or dislocations met the aforementioned standards on standard anteroposterior, lateral, and oblique views.
The self-designed Kirschner wire external fixation traction frame consists of three parts (Fig. 1). The first part of the traction frame is the main component (K1). A 1.5 mm Kirschner wire (K1) is percutaneously inserted 1 cm proximal to the fracture-dislocation, vertically through the midline of the side of the proximal phalanx, and passes through the cortex on the opposite side. The Kirschner wire is bent 90° distally at a point 5 mm from the skin surface of the finger to form a “U” shape. The second part of the traction frame (K2) is positioned at the same horizontal level as the first part, 1 cm distal to the fracture-dislocation, vertically through the midline of the side of the distal phalanx. A 1.2 mm Kirschner wire (K2) is percutaneously inserted, passing through the cortex on the opposite side. The Kirschner wire is bent 90° distally at a point 3 mm from the skin surface of the finger to form a “U” shape. Near the IP joint, the two wires are cut and bent backward to form hooks, which are then secured with a rubber band. The third part of the traction frame (K3) is located on the proximal side of K2, in the same plane and parallel to the other Kirschner wires. An additional Kirschner wire (K3) is inserted percutaneously. If the PIP joint is displaced dorsally, K3 is positioned on the palmar side of K1; if the joint is displaced palmarly, K3 is positioned on the dorsal side of K1 to block K1. Finally, a needle from a syringe is used as a positioning needle, placed at the potential puncture site and designed to guide the direction of needle insertion. After fluoroscopy, using the positioning needle as a reference, the joint space is distracted with a rubber band. Small fracture fragments are leveraged with Kirschner wires (K4) to achieve reduction, followed by fixation with 1–2 crossed 1.0 mm or 1.2 mm Kirschner wires, without penetrating the articular surface. Under C-arm fluoroscopy, the width of the joint space and the reduction status are observed. The width of the joint space is compared with that of the adjacent healthy finger. The tension of the rubber bands on both sides is adjusted. The wound and needle tracks are washed with diluted iodine solution, covered with alcohol-soaked gauze, and dressed with sterile dressing to complete the surgery.
Figure 1.

Schematic diagram of the operation. (A) A frontal view of the simulated fixation using an external Kirschner wire frame. (B) A side view of the simulated fixation using an external Kirschner wire frame.
Postoperative management
Routine postoperative care included prophylactic antibiotics for infection prevention, limb elevation to reduce swelling, analgesics for pain relief, and regular dressing changes for wound care. Patients were instructed to begin active mobilization of the PIP and DIP joints from the first postoperative day. Follow-up radiographs were scheduled on the first day, first week, second week, third week, fourth week, and sixth week postoperatively. Based on the reduction of fracture-dislocations and joint space alignment, the tension of the rubber bands on both sides was adjusted in a timely manner to correct lateral and shortening displacements. If a tendency toward separation was observed on one side, the tension of the rubber band on that side should be reduced; conversely, the tension should be increased. The external fixation frame was removed at 4 weeks postoperatively, and patients were encouraged to engage in rehabilitation exercises. At 6 weeks postoperatively, the remaining Kirschner wires were extracted based on the fracture healing status. This procedure involved disinfecting the puncture sites and using sterile Kirschner wire cutters to remove the exposed wires from one side before extracting the wires from the opposite side.
Clinical result evaluation
Perioperative data, including operative time, average hospital stay, and intraoperative complications, were recorded. The pain visual analog scale (VAS) and range of motion (ROM) were used to evaluate clinical outcomes.
Statistical analysis
Statistical analyses were performed using SPSS version 26.0, with patient descriptive statistics reported as number (n) for categorical variables and mean ± standard deviation (SD) for continuous variables. Paired-sample t-tests were used to compare preoperative and final follow-up postoperative VAS scores and ROM, with P < 0.05 considered statistically significant.
Results
All 44 patients were followed up after surgery for 12–23 months, with an average of (16.0 ± 3.1) months. All patients successfully completed the operation and were discharged from the hospital 3–5 days after surgery, with an average hospitalization time of (4.2 ± 0.8) days. The operation time was 30–50 minutes, with an average of (38.4 ± 5.9) minutes. During the follow-up period, all 44 patients healed successfully. Two cases exhibited finger joint angulation, and four cases experienced pin-tract exudation. These were corrected through timely adjustment of Kirschner wire’ position and tension, as well as anti-inflammatory treatment. No other complications, such as wire breakage, pin-tract infection, or nonunion of fractures, were observed. At the final follow-up, the patients’ VAS scores were significantly lower, while ROM values were significantly higher, and these differences were statistically significant (P < 0.05).
Typical case
A 53-year-old man was admitted to the hospital with swelling and pain in the left middle finger caused by a car accident 2 hours earlier. He was diagnosed with a fracture at the base of the middle phalanx of the left middle finger and a dislocation of the proximal IP joint. Surgical treatment was performed 34 hours after the injury, and the postoperative outcome was favorable (Fig. 2).
Figure 2.

Operative procedure. (A and B) The radiological evidence of failure of preoperative conservative treatment. (C and D) Radiographs of postoperative stent and Kirschner wire fixation. (E and F) The radiographic appearance following removal of Kirschner wires. (G and H) Body-surface images of postoperative stent and Kirschner wire fixation. (I and J) The functional recovery status at the final follow-up.
Discussions
IP joint fractures are challenging, and the majority of injuries involve intra-articular fractures of the base of the middle phalanx combined with subluxation[19].
Common clinical treatment methods for finger joint injuries include external fixation with splints, internal fixation with Kirschner wires, plate and screw fixation, and joint replacement. However, postoperative complications such as varying degrees of pain and stiffness in the IP joints are almost inevitable, ultimately affecting hand function[15]. The use of splints for immobilization carries the risk of re-displacement during the fixation process[20]. Internal fixation with plates and screws allows for direct visualization and reduction of fractures; however, the surgical procedure can disrupt the blood supply to the bone tissue, thereby increasing the risk of delayed union or nonunion of the fracture. Additionally, the surgery may require stripping the periosteum, volar plate, joint capsule, and other soft tissues, which elevates the risk of joint capsule contracture and tendon adhesion, ultimately impairing the mobility of the finger joints[21].
The surgeon should pay attention to several important points: (1) thoroughly evaluate the condition to ensure that the skin and soft tissue of the affected finger meet the surgical requirements; (2) ensure that the Kirschner wires are inserted perpendicularly, ideally through the center of rotation of the phalangeal condyles, to achieve balanced force distribution on both sides; (3) conduct standardized X-ray examinations with regular follow-up and timely adjustments of the rubber band traction force to prevent displacement; (4) maintain the IP joint space in the traction frame consistent with that of the adjacent healthy finger, aiming to keep it at 1–2 mm; (5) perform meticulous, precise surgical operations, striving for a single successful closed reduction of small bone fragments to minimize trauma and prevent further damage or even osteonecrosis; and (6) implement appropriate edema and pain control. Provided that external fixation is stable, timely and well-planned postoperative rehabilitation training is beneficial for IP joint mobility. All subjects in this study achieved good reduction. All cases were performed under digital nerve block anesthesia, which facilitates testing the performance of the fixation frame during active movement of the affected finger intraoperatively. All cases underwent closed reduction, without the need for open reduction, which requires a high level of surgical skill. Regular follow-up was conducted postoperatively to observe the healing of fractures and dislocations and the maintenance of joint reduction. The rubber band tension of the external fixation traction frame was adjusted in a timely manner based on X-ray findings. Patients were encouraged to undergo phased rehabilitation exercises as required by the physician. Follow-up showed satisfactory functional outcomes of the finger joints in all patients.
This technique has several advantageous aspects. First, the surgical fixation materials used are Kirschner wires and rubber bands, which are readily available and cost-effective. Second, the external fixation frame is custom-made according to each patient’s injury condition, making it easy to install and remove. Third, the external fixation is small in volume and lightweight, with minimal impact on the movement of adjacent fingers, and does not interfere with imaging examinations, nor does it obscure the joint surface and fracture fragments. Fourth, the percutaneous external fixation alone or in combination with small incisions for fracture reduction is minimally invasive, preserving the blood supply to the fracture fragments and promoting fracture healing. Fifth, the dynamic traction provided by the external fixation is continuous and adjustable, without damaging the soft tissues such as the joint capsule, tendons, and volar plate, which can prevent contracture of the collateral ligaments, the volar plate, and the joint capsule around the joint, increase the joint space, and provide space for the reduction of phalangeal fractures. Sixth, through the dynamic traction of the external fixation frame, appropriate active movement can be initiated immediately after surgery, providing ample opportunity for later joint recovery and maximizing the restoration of finger function. There are limitations to this study. First, the sample size in this study was relatively small, and the follow-up duration was relatively short. Second, our study was a case series with no control group. Third, the study did not include treatment and follow-up of fractures and dislocations of the IP joints of the thumb. Fourth, further research with larger sample sizes and longer follow-up periods is needed.
Conclusions
The self-designed Kirschner wire external fixation frame combined with limited closed internal fixation for the treatment of IP joint fractures and dislocations is convenient to obtain and cost-effective; it provides reliable fixation, allows dynamic adjustment, minimizes trauma, promotes fracture healing, and facilitates joint function recovery. It is an ideal internal fixation method and is worthy of clinical promotion.
Acknowledgements
Not applicable.
Footnotes
Zhiyong Zhou and Weihao Zhu contribute equally to this work.
Sponsorships or competing interests that may be relevant to content are disclosed at the end of this article.
Contributor Information
Zhiyong Zhou, Email: zzyhtlxm@sina.com.
Weihao Zhu, Email: zhuweihao19950106@163.com.
Xu Sun, Email: sunxu123020@163.com.
Weiwei Jiang, Email: jiangweiwei778899@163.com.
Ethical approval
Our research was approved by the medical ethics committee of our committee. The ethical number is KY 2025-064-01.
Consent
All participants agreed to sign the consent form and to follow the treatment plan.
Sources of funding
All authors declared no sources of funding for our research.
Author contributions
Z.Z., W.Z., X.S., W.J., and Z.L., drafted the manuscript and contributed to reviewing and finalizing the manuscript. All authors reviewed the manuscript for intellectual content and approved the submission.
Conflicts of interest disclosure
The authors have no conflicts of interest to declare.
Research registration unique identifying number (UIN)
ChiCTR2000035018.
Guarantor
Not applicable.
Provenance and peer review
Not applicable.
Data availability statement
All data generated or analyzed during this study are included in the paper. The datasets supporting the conclusions of this article are included within the article.
References
- [1].Kreiger N, Kelsey JL, Harris C, et al. Injuries to the upper extremity: patterns of occurrence. Clin Plast Surg 1981;8:13–19. [PubMed] [Google Scholar]
- [2].Miller EA, Friedrich JB. Management of finger joint dislocation and fracture-dislocations in Athletes. Clin Sports Med 2020;39:423–42. [DOI] [PubMed] [Google Scholar]
- [3].van Onselen EB, Karim RB, Hage JJ, et al. Prevalence and distribution of hand fractures. J Hand Surg Br 2003;28:491–95. [DOI] [PubMed] [Google Scholar]
- [4].Mall NA, Carlisle JC, Matava MJ, et al. Upper extremity injuries in the national football league: part I: hand and digital injuries. Am J Sports Med 2008;36:1938–44. [DOI] [PubMed] [Google Scholar]
- [5].Cotterell IH, Richard MJ. Metacarpal and phalangeal fractures in athletes. Clin Sports Med 2015;34:69–98. [DOI] [PubMed] [Google Scholar]
- [6].Lee JJ, Park HJ, Choi HG, et al. Open reduction of proximal interphalangeal fracture-dislocation through a midlateral incision using absorbable suture materials. Arch Plast Surg 2013;40:397–402. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [7].Leibovic SJ, Bowers WH. Anatomy of the proximal interphalangeal joint. Hand Clin 1994;10:169–78. [PubMed] [Google Scholar]
- [8].O’rourke SK, Gaur S, Barton NJ. Long-term outcome of articular fractures of the phalanges: an eleven year follow up. J Hand Surg Br 1989;14:183–93. [DOI] [PubMed] [Google Scholar]
- [9].Elfar J, Mann T. Fracture-dislocations of the proximal interphalangeal joint. J Am Acad Orthop Surg 2013;21:88–98. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [10].Kostoris F, Addevico F, Murena L, et al. Proposal of a new dynamic distraction device to treat complex periarticular fractures of the metacarpophalangeal joint of long finger. Hand (N Y) 2020;15:87–91. [DOI] [PMC free article] [PubMed] [Google Scholar]
- [11].Keramidas E, Solomos M, Page RE, et al. The Suzuki frame for complex intra-articular fractures of the proximal interphalangeal joint of the fingers. Ann Plast Surg 2007;58:484–88. [DOI] [PubMed] [Google Scholar]
- [12].Aladin A, Davis TR. Dorsal fracture-dislocation of the proximal interphalangeal joint: a comparative study of percutaneous Kirschner wire fixation versus open reduction and internal fixation. J Hand Surg Br 2005;30:120–28. [DOI] [PubMed] [Google Scholar]
- [13].Bain GI, Mehta JA, Heptinstall RJ, et al. Dynamic external fixation for injuries of the proximal interphalangeal joint. J Bone Joint Surg Br 1998;80:1014–19. [DOI] [PubMed] [Google Scholar]
- [14].Hynes MC, Giddins GE. Dynamic external fixation for pilon fractures of the interphalangeal joints. J Hand Surg Br 2001;26:122–24. [DOI] [PubMed] [Google Scholar]
- [15].Le Nen D. Extra-articular fractures of the digital metacarpals and phalanges of the long fingers. Chir Main 2014;33:1–12. [DOI] [PubMed] [Google Scholar]
- [16].Kiefhaber TR, Stern PJ. Fracture dislocations of the proximal interphalangeal joint. J Hand Surg Am 1998;23:368–80. [DOI] [PubMed] [Google Scholar]
- [17].Schenck RR. Classification of fractures and dislocations of the proximal interphalangeal joint. Hand Clin 1994;10:179–85. [PubMed] [Google Scholar]
- [18].Agha RA, Mathew G, Rashid R, et al. Revised strengthening the reporting of cohort, cross-sectional and case-control studies in surgery (STROCSS) guideline: an update for the age of Artificial Intelligence. Prem J Sci 2025;10:100081. [Google Scholar]
- [19].Lee JK, Kim YS, Lee JH, et al. Open reduction and internal fixation for dorsal fracture-dislocation of the proximal interphalangeal joint. Offene reposition und interne fixation dorsaler luxationsfrakturen des proximalen interphalangealgelenkes. Handchir Mikrochir Plast Chir 2020;52:18–24. [DOI] [PubMed] [Google Scholar]
- [20].Taljanovic MS, Jones MD, Ruth JT, et al. Fracture fixation. Radiographics 2003;23:1569–90. [DOI] [PubMed] [Google Scholar]
- [21].Cheah AEJ, Chong AK. Soft-tissue coverage of the hand. Current Orthopaedic Practice 2012;23:336–45. [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
All data generated or analyzed during this study are included in the paper. The datasets supporting the conclusions of this article are included within the article.