Abstract
Despite the advances in arthroscopic rotator cuff repair, postoperative structural failure remains a persistent problem. Retear patterns are commonly classified as type 1 failure, which is associated with the poor quality of the torn tendon edge, and type 2 failure, which occurs at the medial suture site owing to stress concentration within the repaired tendon. Consequently, we propose an arthroscopic medial augmentation technique using a suture tape‐based Krackow construct placed medial to the footprint as an adjunct to conventional rotator cuff repair. By obtaining additional fixation in more medial tendon tissue, this technique may reduce dependence on a compromised tendon stump and may also help distribute the load away from the medial suture site. This Technical Note describes the surgical details of this augmentation method that is intended to provide additional tendon reinforcement and load sharing without altering the surgeon's preferred primary repair configuration.

Despite advances in arthroscopic rotator cuff repair, postoperative structural failure remains a persistent problem. Retear patterns are commonly classified as type 1 failure, which is associated with poor quality of the torn tendon edge, and type 2 failure, which occurs at the medial suture site because of stress concentration within the repaired tendon. 1 , 2 , 3 These patterns suggest that both tissue quality at the tear margin and load distribution within the repaired cuff influence structural integrity.
To address these concerns, an arthroscopic medial augmentation technique using a suture tape‐based Krackow construct placed medial to the footprint has been developed. 4 , 5 By obtaining additional fixation in more medial tendon tissue, this technique is intended to supplement tendon purchase and provide load sharing alongside the primary repair. This Technical Note aims to describe the surgical details, indications, and conceptual rationale for this augmentation method.
SURGICAL TECHNIQUE
Indications for Procedure
Krackow stitch augmentation can be used with any arthroscopic rotator cuff repair. Its purpose is to provide additional tendon reinforcement and load sharing alongside the primary repair, and the number of locking loops can be adjusted according to the tear pattern, tendon quality, and intraoperative findings.
Augmentation may be applied to the supraspinatus, infraspinatus, or subscapularis individually, or to more than 1 tendon when indicated. Because it functions as an adjunct rather than a separate repair method, it can be incorporated into the surgeon's preferred strategy without altering the standard principles of cuff repair. It may be particularly useful when an additional tendon purchase is desired or when the tear is considered to be at an increased risk of postoperative structural failure.
Surgical Procedure
The surgery is performed under general anesthesia combined with an interscalene block in the beach‐chair position (Video 1). The initial step involves adequate mobilization of the torn cuff and visualization of the bursal surface. Before creation of the Krackow construct, the cuff is released as needed and confirmed to be reducible to the footprint without any undue tension (Figure 1). In a representative case, tenodesis of the long head of the biceps tendon is also performed before the augmentation technique is started, although the management of the biceps should be determined according to the individual case.
VIDEO 1.
This video shows Krackow stitch augmentation for arthroscopic rotator cuff repair. After cuff mobilization and adequate visualization, the torn cuff is laterally retracted with a grasper through the anterolateral portal. The supraspinatus tendon medial to the footprint is then viewed from the lateral portal. On the right side of the screen, the intramuscular tendon of the supraspinatus is visible beneath the fascia. The medial border of the tendon insertion is identified. The posteromedial and posterolateral loops are then created medial to the tendon insertion. A suture lasso is introduced through the anterior portal and passed through the cuff from anterior to posterior. The suture tape is then relayed through the tendon to create the posterolateral loop. The posteromedial loop is created in the same fashion. The tape is adjusted to maintain the locking loop configuration. After each loop is created, the slack is removed. Next, the anteromedial and anterolateral loops are created through the posterior portal in the same manner. The tape is relayed through the tendon, and the slack is removed as each loop is completed. After all 4 locking loops are created, the 2 free limbs are tensioned to confirm secure tendon grasp. The view is then switched to the posterolateral portal. Lateral traction on the limbs of the Krackow stitch confirms that the torn cuff can be reduced to the footprint. In this case, rotator cuff repair is performed using a suture‐bridge technique. The green lines indicate the medial‐row tapes, and the yellow arrows indicate the 2 limbs of the Krackow stitch. Krackow stitch augmentation is intended to reinforce the repair by distributing the load medial to the footprint. This is a postrepair glenohumeral joint view from the posterior portal. Video content can be viewed at https://doi.org/10.1002/atn2.70396.
FIGURE 1.

View from the posterolateral portal, right shoulder, and beach‐chair position. After cuff mobilization, the bursal surface of the rotator cuff is well visualized, representing the preparatory stage for the Krackow stitch augmentation. In this case, tenodesis of the biceps tendon has already been performed, although this should be determined according to the individual case.
After preparation, the arthroscope is placed in the lateral portal, and Krackow stitch augmentation is initiated under lateral viewing. The construct is placed in the tendon, medial to the medial edge of the footprint. A single 1.3‐mm SutureTape (Arthrex, Naples, FL) is used to create 4 locking loops, designated as anteromedial (AM), anterolateral, posteromedial (PM), and posterolateral (PL) loops. The stitch spacing and number of locking loops may be adjusted according to individual tear patterns and tissue quality (Figure 2).
FIGURE 2.

View from lateral portal, right shoulder, beach‐chair position. The bursal surface of the supraspinatus tendon is shown, and the intramuscular tendon is visible beneath the fascia (asterisk). The torn cuff is retracted laterally with a grasper to help define the area for Krackow stitch placement medial to the footprint. The 4 locking loops are designated the PM, PL, AM, and AL loops. (AL, anterolateral; AM, anteromedial; PL, posterolateral; PM, posteromedial.)
In the case shown in the video, a supraspinatus tear is the predominant lesion. Therefore, the Krackow stitch is started 1.5 cm medial to the edge of the supraspinatus footprint. In the medial row, the AM and PM loops are placed approximately 1.5 cm medial to the tendon‐bone attachment, with an interval of approximately 0.5 cm between them. The anterolateral and PL loops are then created as the lateral row with a pitch of 0.5 cm from the medial row, corresponding to a position 1.0 cm medial to the medial edge of the footprint.
The stitch passage begins at the PM loop. With the subacromial space visualized through the lateral portal, a 45° curved SutureLasso SD (Arthrex, Naples, FL) introduced through the anterior portal is passed through the tendon from anterior to posterior, perpendicular to the tendon fiber orientation (Figure 3). A 1.3‐mm suture tape is then shuttled through the tendon using a suture relay technique. The loop is completed by retrieving the posterior limb through the anterior portal and the anterior limbs via the posterolateral portal (Figure 4). The PL loop is then created in the same manner by relaying the tape that has been previously retrieved through the posterolateral portal (Figure 5). The PL limb is adjusted to pass superior to the PM limb before the second loop is completed. If the PL entry point lies posterior to the PM limb, this maneuver is unnecessary. After the creation of the PL loop, a grasper is used to remove the slack and gently tension the tape (Figure 6).
FIGURE 3.

View from lateral portal, right shoulder, beach‐chair position. During creation of the PM loop, a suture lasso is inserted through the anterior portal and passed through the tendon from anterior to posterior (arrows indicate the entry and exit points). At the exit point of the lasso, a retriever is used to assist the maneuver by pressing the tendon from the bursal side. A 1.3‐mm suture tape is subsequently shuttled through the tendon from posterior to anterior using a suture relay technique. (PM, posteromedial.)
FIGURE 4.

Right shoulder viewed from the lateral portal during completion of the PM loop. The posterior limb exiting on the bursal surface of the tendon is retrieved to the anterior portal, and the anterior limb exiting on the bursal surface is then retrieved to the posterolateral portal so that it passes over the limb previously brought to the anterior portal. This maneuver completes the PM loop. The dotted line indicates the presumed intratendinous course of the tape. (PM, posteromedial.)
FIGURE 5.

Right shoulder viewed from the lateral portal. For creation of the PL loop, a suture lasso was again introduced through the anterior portal and passed through the tendon from anterior to posterior (arrows indicate the entry and exit points). The tape is then shuttled through the tendon from posterior to anterior using a suture relay technique. The anterior limb of the PL loop is finally adjusted to pass over the anterior limb of the PM loop, thereby completing the PL loop. (PL, posterolateral; PM, posteromedial.)
FIGURE 6.

Right shoulder viewed from the lateral portal after completion of the PL loop. A grasper is used to remove slack and gently tension the tape. The completed PM and PL loops are shown. Solid lines indicate the course of the tape on the tendon surface hidden by tissue, and dotted lines indicate the presumed intratendinous course of the tape. (PL, posterolateral; PM, posteromedial.)
Next, an AM loop is created. A suture lasso is introduced through the posterior portal and passed through the cuff from the posterior to the anterior (Figure 7). The tape is brought out through the anterior portal and then relayed through the cuff to complete the third loop. The posterior limb of the AM loop is arranged to pass over the transverse tape, and after the loop is completed, the posterior limb is pulled laterally to remove the slack (Figure 8). The anterolateral loop is created similarly (Figure 9). After the slack is removed, the Krackow stitch is completed using 4 locking loops (Figure 10).
FIGURE 7.

Right shoulder viewed from the lateral portal. During creation of the AM loop, a suture lasso is introduced through the posterior portal and passed through the cuff from posterior to anterior (arrows indicate the entry and exit points). The posterior limb of the PM loop is then relayed through the cuff from anterior to posterior. Care is taken to ensure that the posterior limb of the AM loop passes over the transverse tape. (AL, anterolateral; AM, anteromedial; PM, posteromedial.)
FIGURE 8.

Right shoulder viewed from the lateral portal. The posterior limb of the AM loop is pulled laterally to remove slack, thereby completing the AM loop. (AM, anteromedial.)
FIGURE 9.

Right shoulder viewed from the lateral portal. During creation of the AL loop, a suture lasso is inserted through the posterior portal and passed through the cuff from posterior to anterior (arrows indicate the entry and exit points). The posterior limb of the AM loop is then relayed through the cuff from anterior to posterior. Care is taken to ensure that the posterior limb of the AL loop passes over the posterior limb of the AM loop. (AL, anterolateral; AM, anteromedial.)
FIGURE 10.

Right shoulder viewed from the lateral portal. After slack is removed from the tape, the Krackow stitch is completed with 4 locking loops. The 2 free limbs are then pulled laterally to confirm secure tendon grasp and reduction.
Lateral traction of the 2 free limbs confirms the reduction of the torn cuff edge and secures the tendon grasp. In a representative case, the cuff is repaired using the suture‐bridge technique with 8 limbs from 2 medial‐row anchors (4.75‐mm HEALICOIL REGENESORB Suture Anchors; Smith & Nephew, Andover, MA). Simultaneously, the 2 limbs from the Krackow stitch are secured in a straight configuration with anterior and posterior lateral‐row anchors (4.75‐mm BioComposite SwiveLock C Anchors; Arthrex, Naples, FL), thereby completing the augmentation (Figure 11).
FIGURE 11.

Right shoulder viewed from the lateral portal. Rotator cuff repair is performed with a suture‐bridge technique using 8 limbs from 2 medial‐row anchors. Simultaneously, the 2 limbs from the Krackow stitch are secured in a straight configuration with the anterior and posterior lateral‐row anchors, thereby completing the Krackow stitch augmentation. Arrows indicate the 2 Krackow‐derived limbs.
The main technical pearls and pitfalls of this procedure are summarized in Table 1. The potential advantages and disadvantages of this augmentation technique are listed in Table 2.
TABLE 1.
Pearls and Pitfalls of Krackow Stitch Augmentation
| Pearls | Pitfalls |
|---|---|
| Obtain sufficient visualization of the bursal surface before creating the Krackow construct. | Inadvertently incorporates the surrounding soft tissue when visualization is insufficient. |
| Perform adequate cuff mobilization to allow low‐tension footprint reduction. | Overtensioning of the construct during fixation. |
| Direct locking passes toward the tendinous tissue rather than muscle alone, whenever possible. | Passing the tape through the muscle tissue alone. |
| Do not strongly tension the tape until each locking loop has been clearly formed. | Strongly pulling the tape before the locking loop has been formed, causing the tape to become buried within the tissue. |
| Remove slack from the tape stepwise during loop creation. | Fixing the construct while residual slack remains in the locking loops. |
| Maintain balanced tension between the Krackow construct and primary repair. | Creating an imbalance between the Krackow construct and primary repair tension. |
TABLE 2.
Advantages and Disadvantages
| Advantages | Disadvantages |
|---|---|
| Can be incorporated without altering the surgeon's preferred repair strategy. | Overtension may contribute to postoperative pain or stiffness. |
| Can be applied to the supraspinatus, infraspinatus, or subscapularis, either individually or in combination. | Inadequate visualization may increase the risk of unintended suture passage through the surrounding tissue. |
| Provides additional tendon purchase in the tissue medial to the torn edge. | This technique is technically demanding and may increase operative time. |
| May reduce dependence on poor‐quality tendon stump tissue. | Complete arthroscopic visualization of the intramuscular tendon is not always possible. |
| The number and spacing of locking loops can be adjusted according to the tear pattern and tissue quality. | The biomechanical and clinical benefits of this augmentation remain unproven. |
DISCUSSION
The principal aim of this technique is to provide adjunctive medial tendon reinforcement during arthroscopic rotator cuff repair without replacing the surgeon's preferred primary repair construct. This Krackow construct is intended as an augmentation rather than an alternative repair method, providing additional tendon purchase and load sharing along with the primary repair. 6
One potential advantage of this augmentation is that it reduces dependence on the degenerative torn tendon edge by obtaining additional fixation in the more medial tendon tissue. Conventional cuff suturing often relies heavily on the tissue quality at or near the tear margin. 7 , 8 However, in chronic or degenerative tears, the tendon stump may be frayed, attenuated, or structurally compromised, making secure suture purchase more difficult and predisposing the construct to cut through or loss of fixation. In this setting, a technique that captures the tendon tissue medial to the torn edge may serve as a useful adjunct reinforcement strategy. 6 , 9
The rationale for selecting a Krackow‐type configuration is supported by its long‐standing role as a dependable tendon‐holding stitch. 5 , 10 Although the stitch itself is not novel, its use as an arthroscopic medial augmentation strategy in rotator cuff repair has not been clearly established. The time‐tested tendon‐grasping principle addresses the practical problem of insufficient purchase at a compromised tendon edge. 9 , 11 , 12
An additional technical consideration is that a Krackow‐type construct should engage the tendinous tissue rather than the muscle tissue whenever possible. Because complete arthroscopic visualization of the intramuscular tendon is usually not feasible, the surgeon must estimate its location based on known anatomy and preoperative imaging. 13 , 14 , 15 Accordingly, the medial locking passes should be directed toward the tissue that most likely corresponds to the intratendinous portion of the cuff while avoiding reliance on the muscle tissue alone. 16
This concept is also consistent with the general augmentation principles in rotator cuff surgery, in which the goal is reinforcement and load sharing rather than mechanical dominance over the primary repair. If the Krackow construct is too loosely tensioned, its reinforcing effect may be negligible; if it is too tightly tensioned, it may stress‐shield the primary repair or contribute to overtightening of the repaired cuff. Accordingly, the construct should be tensioned to a level that is mechanically balanced with the primary cuff repair. 17 , 18 , 19 , 20 , 21
However, this technique has some limitations. It is technically demanding and may increase operative complexity and surgical time. Inadequate visualization may lead to passage through the surrounding soft tissue, and excessive tension may contribute to postoperative pain or stiffness. Because this technique is intended strictly as augmentation, its success still depends on the quality and mechanics of the primary repair and should not be viewed as a substitute for adequate mobilization, appropriate repair tension, or sound footprint fixation. 22
Most importantly, no dedicated biomechanical data validate this specific construct for rotator cuff repair or show that medial Krackow augmentation with suture tape improves repair biomechanics or reduces the risk of type 2 retears. Similarly, clinical outcome data have not shown that this augmentation improves healing or structural integrity after repair. Accordingly, the present report should be understood as a description of a potentially useful surgical concept and technical option, rather than proof of superiority over established methods. Future biomechanical and clinical studies are required to determine whether augmentation improves healing and decreases postoperative medial cuff failure.
DECLARATION OF GENERATIVE AI AND AI‐ASSISTED TECHNOLOGIES IN THE WRITING PROCESS
During the preparation of this work, the authors used ChatGPT (OpenAI) for English translation and NaturalReader for video narration. After using this tool/service, the authors reviewed and edited the content as needed and take full responsibility for the content of the publication.
DISCLOSURES
The authors (H.N., Y.M., R.A., S.S., K.H., T.Y., M.G.) declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
ACKNOWLEDGMENTS
The authors thank Editage for providing English language editing of the manuscript.
REFERENCES
- 1. Cho NS, Lee BG, Rhee YG. Arthroscopic rotator cuff repair using a suture bridge technique: Is the repair integrity actually maintained? Am J Sports Med. 2011;39:2108‐2116. [DOI] [PubMed] [Google Scholar]
- 2. Lee WY, Cho HH, Jeon YS, et al. Comparison of clinical and biomechanical results of arthroscopic rotator cuff repair using conventional and triple‐row suture‐bridge techniques. J Orthop Surg (Hong Kong). 2025;33:10225536251364198. [DOI] [PubMed] [Google Scholar]
- 3. Shimokobe H, Gotoh M, Honda H, et al. Risk factors for retear of large/massive rotator cuff tears after arthroscopic surgery: An analysis of tearing patterns. J Orthop Surg Res. 2017;12:140. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4. Krackow KA, Thomas SC, Jones LC. A new stitch for ligament‐tendon fixation. Brief note. J Bone Joint Surg Am. 1986;68:764‐766. [PubMed] [Google Scholar]
- 5. Sherman SL. Editorial commentary: The Krackow stitch: More than 30 years of tendon repair and still holding strong. Arthroscopy. 2018;34:669‐670. [DOI] [PubMed] [Google Scholar]
- 6. Cho NS, Yi JW, Lee BG, Rhee YG. Retear patterns after arthroscopic rotator cuff repair: Single‐row versus suture bridge technique. Am J Sports Med. 2010;38:664‐671. [DOI] [PubMed] [Google Scholar]
- 7. Takeuchi N, Kozono N, Nishii A, et al. Stump classification was correlated with retear in the suture‐bridge and double‐row repair techniques for arthroscopic rotator cuff repair. Knee Surg Sports Traumatol Arthrosc. 2021;29:2587‐2594. [DOI] [PubMed] [Google Scholar]
- 8. Kawamata J, Fukuta S, Kano M, Yoshikawa K, Sairyo K. Tendon stump change as a risk factor for structural failure of arthroscopic rotator cuff repair. JSES Int. 2025;9:1118‐1123. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Rashid MS, Lo IKY. Editorial commentary: Causes of failure after arthroscopic rotator cuff repair. Arthroscopy. 2021;37:2087‐2089. [DOI] [PubMed] [Google Scholar]
- 10. Hahn JM, Inceoglu S, Wongworawat MD. Biomechanical comparison of Krackow locking stitch versus nonlocking loop stitch with varying number of throws. Am J Sports Med. 2014;42:3003‐3008. [DOI] [PubMed] [Google Scholar]
- 11. Brusalis CM, Fenn TW, Larson JH, Hapa O, Nho SJ. All‐endoscopic modified Krackow suture for proximal hamstring repair. Arthrosc Tech. 2023;12:e1473‐e1478. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 12. Haroun Y, Sobhy MH, et al. Comparison between 4 different suture configurations for rotator cuff repair: A biomechanical animal study. SICOT J. 2024;10:39. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13. Grant JA, Miller BS, Jacobson JA, et al. Intra‐ and inter‐rater reliability of the detection of tears of the supraspinatus central tendon on MRI by shoulder surgeons. J Shoulder Elbow Surg. 2013;22:725‐731. [DOI] [PubMed] [Google Scholar]
- 14. Mochizuki T, Sugaya H, Uomizu M, et al. Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff. J Bone Joint Surg Am. 2008;90:962‐969. [DOI] [PubMed] [Google Scholar]
- 15. Volk AG, Vangsness CT Jr. An anatomic study of the supraspinatus muscle and tendon. Clin Orthop Relat Res. 2001;384:280‐285. [DOI] [PubMed] [Google Scholar]
- 16. Jernheden I, Szaro P. The internal structure of the infraspinatus muscle: A magnetic resonance study. Surg Radiol Anat. 2022;44:1439‐1453. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Park JS, McGarry MH, Campbell ST, et al. The optimum tension for bridging sutures in transosseous‐equivalent rotator cuff repair: A cadaveric biomechanical study. Am J Sports Med. 2015;43:2118‐2125. [DOI] [PubMed] [Google Scholar]
- 18. Hackl M, Nacov J, Kammerlohr S, et al. Intratendinous strain variations of the supraspinatus tendon depending on repair technique: A biomechanical analysis regarding the cause of medial cuff failure. Am J Sports Med. 2021;49:1847‐1853. [DOI] [PubMed] [Google Scholar]
- 19. Steinhaus ME, Makhni EC, Cole BJ, Romeo AA, Verma NN. Outcomes after patch use in rotator cuff repair. Arthroscopy. 2016;32:1676‐1690. [DOI] [PubMed] [Google Scholar]
- 20. Xiao M, Abrams GD. Editorial commentary: Tension of the repair during rotator cuff surgery appears to matter more than medial‐lateral footprint coverage. Arthroscopy. 2025;41:2269‐2270. [DOI] [PubMed] [Google Scholar]
- 21. Miyake S, Shibata T, Kobayashi S, et al. Risk factors for high repair tension during rotator cuff repair. Orthop J Sports Med. 2024;12:23259671241276445. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Huntington LS, Coles‐Black J, Richardson M, et al. The use of suture‐tape and suture‐wire in arthroscopic rotator cuff repair: A comparative biomechanics study. Injury. 2018;49:2047‐2052. [DOI] [PubMed] [Google Scholar]
