Skip to main content
NIHPA Author Manuscripts logoLink to NIHPA Author Manuscripts
. Author manuscript; available in PMC: 2026 Nov 13.
Published in final edited form as: Optom Vis Sci. 2026 Oct;103(10):e70107. doi: 10.1002/ovs2.70107

Interocular Symmetry of Ocular Rigidity and Related Ocular Parameters in Isometropia

Jonathan Medina-Cornejo 1, Kelly Lam 1, Yasaman Adel 1, Nimesh B Patel 1, Diane N Sayah 1
PMCID: PMC13759021  NIHMSID: NIHMS2218795  PMID: 42841226

Abstract

Purpose:

Driven by scleral stiffness, ocular rigidity (OR) is emerging as a critical factor in refractive development. While a common assumption is that OR is symmetric in a healthy individual’s eyes, empirical data remains scarce. This study directly tests this assumption by quantifying intereye OR differences in healthy, isometropic subjects.

Methods:

Isometropia was defined as intereye differences in spherical equivalent refraction (SER) of <0.50 diopters (D) and axial length (AL) of <0.15 mm. OR was measured using a validated method based on video-rate optical coherence tomography imaging and dynamic contour tonometry. A neural network approach was used to segment the choroid, obtain the pulsatile choroidal thickness and the volume (ΔV) change. OR was estimated based on Friedenwald’s pressure-volume relationship using the ΔV and the ocular pulse amplitude. In addition to OR, other acquired measurements included the aqueous depth (AD), central corneal thickness, Pascal-intraocular pressure (IOP), Goldmann correlated IOP, corneal compensated IOP, corneal hysteresis and corneal resistance factor (CRF).

Results:

Thirty-six subjects aged 17±6 years were enrolled, 33% of whom had isomyopia. Mean (SD) SER was −0.69 (1.48) D in OD and −0.68 (1.41) D in OS (p=0.88), and mean AL was 23.79 (0.94) mm in OD and 23.78 (0.94) mm in OS (p=0.36). No difference in OR was found between the right 0.017 (0.011)/μL and left 0.018 (0.012)/μL eyes (p=0.74; mean difference= −0.0003/μL). No significant intereye differences were observed for most parameters, although right eyes had slightly higher values for AD (0.03 mm, p<0.001), CRF (0.3 mmHg, p=0.006), and subfoveal choroidal thickness (11.5 μm, p=0.010).

Conclusions:

Our findings primarily show that OR displays strong interocular symmetry in healthy individuals with isometropia. Establishing normative symmetry of OR in living human eyes lays the groundwork for the biomechanical basis of refractive development and myopia, indicating that intereye differences in OR may reflect pathological change.

Significance:

Using a validated, non-invasive method, this study demonstrates that healthy individuals with isometropia exhibit highly symmetric ocular rigidity. Defining this normal intereye correspondence creates a valuable baseline for clinical research, providing a framework to isolate pathological structural asymmetry in conditions like glaucoma and anisometropia.

Keywords: ocular rigidity, refractive error, myopia, isometropia, biomechanics, sclera

Introduction

The sclera plays an important role in ocular growth and refractive development, including axial myopia. Myopia, or nearsightedness, is becoming a serious global public health problem due to its alarmingly increasing prevalence1, 2, and associated sight-threatening complications. Efforts are thus being deployed to better understand the mechanisms leading to excessive ocular growth, and detecting early progression to myopia.

The sclera, outer shell of the eye, is responsible for maintaining the eye’s shape, and ensuring optimal vision by modulating its length to allow light rays to focus on the retina3. It plays an active role in refractive development through remodeling of its extracellular matrix, leading to structural and biomechanical changes. During emmetropization, the eye grows and elongates until it is adjusted to the optical power of the eye4. In myopia, excessive elongation of the eye shifts the focal point in front of the retina, resulting in blurred distance vision but also leading to changes in the biomechanical properties5–7. The sclera becomes thinner, exhibits an increased creep rate, and loses biomechanical strength, all of which may render it more susceptible to further elongation8, 9. Ocular rigidity (OR) was defined by Jonas Friedenwald, a prominent ophthalmologist and scientist, as a “measure of the resistance, which the eye exerts to distending forces”10. OR is a global parameter, yet is primarily determined by the stiffness of the sclera which composes 80% of the eye’s outer surface. OR is described by the following pressure-volume relationship, also named Friedenwald’s equation10:

lnIOP/IOP0=ORV−V0.

In this equation, IOP is the intraocular pressure and V is the ocular volume. The gold standard measurement for OR is invasive and involves a manometric method where the eye is cannulated, injected with a known volume of fluid, and the corresponding IOP change is simultaneously measured11. Due to the invasiveness of the procedure, OR measurement has been limited to intraoperative cases, thus limiting the investigation of OR in refractive development and myopia in young healthy subjects. A direct non-invasive approach was developed to measure pulse-induced pressure-volume changes. This method uses video-rate optical coherence tomography (OCT) imaging and automated choroidal segmentation combined with Pascal tonometry to measure the pulsatile choroidal volume change (ΔV), and the ocular pulse amplitude respectively, and compute OR12, 13. This method has been validated against an invasive procedure and OR coefficients obtained invasively and non-invasively were found to be well correlated13. Using this optical method to measure OR in large cohorts, the role of OR in diseases such as open-angle glaucoma14–17, retinal diseases18, axial myopia19, 20, and spaceflight-associated neuro-ocular syndrome21, 22 was investigated. Lower OR (ie. more compliant sclera) was found in eyes with axial myopia compared to non-myopic eyes19, confirming previous reports using the intraoperative procedure23. Despite these advancements, important gaps in our understanding of the role of the sclera in eye growth and refractive development remain. An important and foundational question is whether OR is symmetric in both eyes of a healthy individual considering isometropic conditions. Establishing baseline interocular symmetry is a critical first step in understanding the role of OR in refractive development and myopia. To address this question, the objective of this study is to characterize interocular differences in OR in healthy subjects with isometropia.

Materials & Methods

This prospective study was approved by the University of Houston institutional review board (IRB, approval number 4296) and followed the tenets of the Declaration of Helsinki. Written informed consent (or parental permission and child assent for minor subjects) was obtained prior to any testing for all subjects.

Healthy subjects aged ≥ 6 years were recruited from the University Eye Institute at the University of Houston College of Optometry and the community as part of a larger prospective study. Subjects were included in this study if they had healthy eyes with isometropia. To characterize interocular symmetry, we defined isometropia using stricter criteria than the conventional threshold for anisometropia (commonly defined as an interocular difference in spherical equivalent refraction (SER) of ≥1.00 D or ≥ 0.50D)24. In this study, isometropia was defined as an inter-eye SER difference of <0.50 D and an ocular axial length (AL) difference of <0.15 mm. The AL criterion was selected based on the approximation that a 1 mm difference in AL corresponds to a refractive difference of approximately 2.5 to 3 D25. Subjects were excluded from the study if they had a history of ocular or systemic disease, an intraocular pressure ≥ 21 mm Hg, eye trauma or surgery, media opacities, unstable fixation, or a heavily pigmented choroid that precluded choroidal imaging. Additionally, individuals with a history of or currently treated for myopia control, as well as rigid contact lens wearers, were excluded.

Data collected on both eyes included SER using an open-field autorefractor (WAM-5500, grandseiko.com), AL and other biometric measurements such as the aqueous depth (AD) and central corneal thickness (CCT) (Lenstar LS900, haag-streit.com), IOP and the ocular pulse amplitude (OPA, Pascal tonometer, ziemergroup.com), and ocular rigidity measurements using our validated, non-invasive approach. Goldmann correlated IOP (IOPg), corneal compensated IOP (IOPcc), corneal hysteresis (CH), and resistance factor (CRF) were also measured using the Ocular Response Analyzer (ORA G3, Reichert.com). At least three measurements per eye were acquired using the ORA G3. For each eye, the single measurement with the highest waveform score (WS; quality score) was selected. Only measurements with WS greater than 5.0 in both eyes were included in the analysis.

The non-invasive measurement method for OR used in this study has been described in detail26. Briefly, video-rate OCT of the choroid is carried out using the Spectralis OCT2 (HeidelbergEngineering.com) with enhanced depth imaging mode. A neural network approach is used to segment the choroid and extract the volume of choroidal filling using a two-sphere model of the eye based on biometric data such as AL. The choroid is delineated in each frame of the video; the mean subfoveal choroidal thickness (CT) is calculated for each B-scan, and the pulsatile choroidal thickness change (ΔCT) is computed for the time-series. Since the choroid accounts for approximately 90% of the total ocular blood flow, we extrapolate ΔV from ΔCT using a two-sphere mathematical model of the choroid13 in which ΔV is equal to π2(ALadj+CT)2ΔCT, where ALadj is adjusted for the anterior chamber depth. During OCT video acquisition, finger oximetry is used to obtain the subject’s heart rate which is then used to confirm that choroidal fluctuations are due to the heart rate through a frequency spectrum analysis12, 26. Coupling ΔV with the ocular pulse amplitude, the OR is then computed using Friedenwald’s equation. This method, which has been validated against an invasive procedure13, was found to have good repeatability in adults and children26, and has been used to study OR in pathological processes in the eye14–16, 18–20.

Descriptive statistics were performed using Prism v.10 (GraphPad.com). Depending on data normality, paired t-test or the Wilcoxon signed-rank test was used to assess inter-eye differences. Inter-eye agreement was further evaluated using Bland-Altman analysis (including mean difference and 95% limits of agreement [LoA]), and intraclass correlation coefficients (ICC; two-way random effects model, single measure, absolute agreement). Pearson correlation or Spearman rank correlation was used to investigate correlations between the right and left eyes. A sensitivity analysis was carried out to verify the impact of the assumptions of normality on the results. If the results were robust to both statistical methods, the Pearson correlation coefficient was reported. A p-value ≤ 0.05 was considered significant.

Results

Thirty-six healthy subjects (14 males) with mean (SD) age 17 (6) years (range of 9 to 36 years) were included in this study. Reflecting local diversity, our sample was 44% Hispanic, 31% Black, 14% White, and 11% Asian. Spherical refractive error ranged from −5.43D to +1.38D, with twelve subjects (33%) presenting with isomyopia (SER ≤ −0.50 D in each eye). All measurements including auto-refraction, tonometry, ocular biometry and non-invasive OR measurements were acquired in both eyes for each subject. Clinical characteristics, interocular mean differences, and 95% LoAs are summarized in Table 1. No significant interocular difference was observed for OR, with mean (SD) values of 0.017 (0.011) /μL in the right eye and 0.018 (0.012) /μL in the left eye (p=0.74), and mean interocular difference of −0.0003/μL (Figure 1). Similarly, fellow eyes exhibited no significant difference for all other measurements, including SER, AL and Pascal-IOP (Figure 2). Small statistical differences were found for AD (mean difference = 0.03 mm, p<0.001), CRF (mean difference = 0.3 mmHg, p=0.006) and CT (mean difference = 11.5 μm, p=0.010), with higher values in the right eye. Overall, all parameters demonstrated strong interocular correlation and moderate to excellent agreement between the right and left eyes (Table 2). For OR specifically, the ICC and Bland-Altman analysis confirmed high inter-eye agreement (ICC = 0.87; mean difference = −0.0003/μL, 95% LoA: −0.012, 0.012) (Table 2; Figure 3).

Table 1.

Clinical characteristics for 36 young healthy subjects with isometropia. Data is presented as mean (SD) where applicable.

Right Eye Left Eye Mean difference 95% LoA p-value
Spherical equivalent refraction (D) −0.69 (1.48) −0.68 (1.41) −0.01 −0.47, 0.46 0.88
Axial length (mm) 23.79 (0.94) 23.78 (0.94) 0.01 −0.15, 0.17 0.36
Aqueous depth (mm) 3.16 (0.30) 3.13 (0.29) 0.03 −0.05, 0.11 <0.001
Central corneal thickness (μm) 558 (31) 557 (31) 1.6 −11.2, 14.3 0.16
Pascal-IOP (mmHg) 15.3 (2.1) 14.9 (2.1) 0.4 −2.39, 3.24 0.085
Ocular pulse amplitude (mmHg) 2.0 (0.8) 2.0 (0.6) 0.04 −1.03, 1.11 0.67
Goldmann correlated IOP (mmHg) 15.8 (3.9) 15.4 (3.7) 0.4 −3.42, 4.27 0.20
Corneal compensated IOP (mmHg) 14.4 (3.1) 14.2 (3.0) 0.2 −3.94, 4.39 0.53
Corneal hysteresis (mmHg) 12.1 (1.2) 11.9 (1.4) 0.2 −1.07, 1.39 0.14
Corneal resistance factor (mmHg) 12.0 (1.9) 11.7 (2.0) 0.3 −0.80, 1.35 0.006
Mean subfoveal choroidal thickness (μm) 313.0 (52.0) 301.6 (49.9) 11.5 −38.2, 61.2 0.010
Pulsatile choroidal thickness change (μm) 13.2 (6.5) 13.9 (7.5) −0.7 −10.4, 9.0 0.39
Pulsatile choroidal volume change (μL) 9.1 (4.4) 9.6 (5.3) −0.5 −7.1, 6.1 0.36
Ocular rigidity (1/μL) 0.017 (0.011) 0.018 (0.012) −0.0003 −0.012, 0.012 0.74

IOP = intraocular pressure; LoA = limits of agreement

Figure 1.

Figure 1.

Plot comparing the distribution of ocular rigidity in the right (OD) and left (OS) eyes of 36 individuals with isometropia defined as SER < 0.50 D and AL < 0.15 mm. Mean ocular rigidity was 0.017 ± 0.011/μL in OD and 0.018 ± 0.012/μL in OS (p=0.74), demonstrating no inter-eye difference in ocular rigidity in isometropia.

Figure 2.

Figure 2.

Plots showing the distribution of spherical equivalent refraction (mean ± SD for OD: −0.69±1.48 D; OS: −0.68±1.41 D, p=0.88) (left); axial length (OD: 23.79±0.94 mm and OS: 23.78±0.94 mm, p=0.36) (center); and Pascal-IOP (OD: 15.3 ± 2.1 mmHg, OS: 14.9 ± 2.1 mmHg, p=0.09) (right), in 36 subjects with isometropia. No significant inter-eye differences were found for all these parameters.

Table 2.

Pearson and intraclass correlation coefficients between right and left eye parameters in isometropia (n=36).

Pearson p-value ICC (95% CI)
Spherical equivalent refraction 0.99 <0.001 0.99 (0.97–0.99)
Axial length 1.00 <0.001 1.00 (0.99–1.00)
Aqueous depth 0.99 <0.001 0.99 (0.95–1.00)
Central corneal thickness 0.98 <0.001 0.98 (0.96–0.99)
Pascal IOP 0.76 <0.001 0.75 (0.56–0.86)
Ocular pulse amplitude 0.73 <0.001 0.72 (0.51–0.85)
Goldmann correlated IOP 0.87 <0.001 0.87 (0.75–0.93)
Corneal compensated IOP 0.76 <0.001 0.76 (0.58–0.87)
Corneal hysteresis 0.89 <0.001 0.88 (0.78–0.94)
Corneal resistance factor 0.96 <0.001 0.95 (0.88–0.98)
Mean subfoveal choroidal thickness 0.88 <0.001 0.86 (0.71–0.93)
Pulsatile choroidal thickness change 0.76 <0.001 0.75 (0.56–0.86)
Pulsatile choroidal volume change 0.77 <0.001 0.76 (0.58–0.87)
Ocular rigidity 0.87 <0.001 0.87 (0.76–0.93)

CI = confidence interval; ICC = intraclass correlation coefficient; IOP = intraocular pressure

Figure 3.

Figure 3.

Bland-Altman plot showing the inter-eye agreement for ocular rigidity in the right and left eyes of 36 individuals with isometropia. The blue dotted lines represent the lower (−0.012/μL) and upper (0.012/μL) 95% Limits of Agreement (LoA). The red line represents the mean inter-eye difference in OR (OROD – OROS = −0.0003/μL).

Discussion

In this study, we demonstrate strong inter-eye symmetry in ocular rigidity among individuals with isometropia. A common assumption is that OR should be equal in both eyes of a healthy individual, yet this has not been previously established. Since OR reflects the stiffness of the sclera, this symmetry implied that both eyes develop and maintain similar biomechanical properties under normal conditions. By confirming that inter-eye differences are minimal in our isometropic cohort, our findings validate this common assumption. Establishing this normative baseline provides a reference point for future research exploring how changes in scleral biomechanics contribute to refractive development and disease.

In addition to OR, we evaluated several related ocular biometric and biomechanical parameters to determine whether symmetry extended across these measures. Our findings show robust interocular symmetry in CCT, Pascal-IOP, OPA, IOPg, IOPcc, CH, ΔCT and ΔV within our isometropic cohort. While no previous studies have reported inter-eye comparisons for ΔCT and ΔV, the symmetry observed across the remaining parameters aligns with prior work. Large-scale studies in healthy adults have demonstrated excellent correspondence between fellow eyes in SER, IOP, ACD, CCT, AL, LT, and other biometric variables27, 28. Prior research assessing tonometric and corneal biomechanical metrics have likewise reported minimal or no interocular differences in IOPcc and CH, although IOPg has been noted to be slightly higher in the first measured eye29. Collectively, these studies support the concept that the healthy eye exhibits strong bilateral symmetry across biometric and biomechanical properties—a pattern that this study extends to OR in isometropia.

Although symmetry predominated across parameters, we observed small but statistically significant differences in AD (mean difference=0.03 mm), CRF (mean difference=0.3 mmHg), and CT (mean difference=11.5 μm) in our cohort, with all these metrics tracking higher in the right eye. However, based on the repeatability of these measurements, the differences in AD30, 31 and CRF32–34 are deemed not clinically significant. Indeed, an ex vivo study in rabbit eyes reported comparable values of CRF between eyes under controlled IOP conditions, showing a similar non-significant trend toward slightly higher CRF in the right eye (mean difference in CRF=0.32 mmHg at IOP level of 15.0 mmHg)35. Interocular CT differences are likewise well documented, with most clinical studies reporting greater thickness in the right eye36–41. Several mechanisms have been proposed to explain these minor asymmetries, including vascular differences in the right and left carotid artery anatomy42, and variations in ocular dominance, which may modulate and increase metabolic demand in the dominant (often right) eye43. Additionally, many clinical studies, including this one, acquire measurements from the right eye first. While the absence of randomization is a limitation which could theoretically influence certain variables, its effect is likely minimal for most parameters, including OR, given the overall symmetry of results reported in this study.

Conclusion

In summary, our findings demonstrate that OR and most related ocular parameters are highly symmetric in healthy individuals with isometropia. Establishing this normative interocular symmetry has important implications for both research and clinical practice. In research, symmetry provides baseline assumptions that can inform study design and statistical modeling (eg.: allowing the use of fellow eyes as internal controls)44. Clinically, deviations from this expected symmetry may serve as early, sensitive indicators of unilateral pathological change. By defining expected inter-eye correspondence in OR, this study provides a valuable reference point for future work involving refractive development, anisometropia, glaucoma, and other conditions in which asymmetry plays a diagnostic or mechanistic role.

Funding:

This work was supported by research grants provided by the Beta Sigma Kappa Research Fellowship, the American Academy of Optometry Foundation, and the National Institutes of Health T35 (EY007088-40) and P30 grant (EY007551). The funding organizations had no role in the design or conduct of this research.

Footnotes

Competing Interests: Nimesh B. Patel reports consulting for AbbVie, which is unrelated to the present manuscript. All other authors declare they have no competing interests.

Ethics approval: This prospective study was approved by the University of Houston institutional review board (IRB, approval number 4296) and followed the tenets of the Declaration of Helsinki.

Patient consent: Written informed consent (or parental permission and child assent for minor subjects) was obtained prior to any testing for all subjects.

Data availability statement:

The data supporting the findings of this study may be made available from the corresponding author upon reasonable request, subject to institutional and ethical approvals.

References

  • 1.Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS, Sankaridurg P, et al. Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. Ophthalmology. 2016;123(5):1036–42. Epub 2016/02/15. [DOI] [PubMed] [Google Scholar]
  • 2.Wong TY, Ferreira A, Hughes R, Carter G, Mitchell P. Epidemiology and disease burden of pathologic myopia and myopic choroidal neovascularization: an evidence-based systematic review. Am J Ophthalmol. 2014;157(1):9–25 e12. Epub 2013/10/09. [DOI] [PubMed] [Google Scholar]
  • 3.McBrien NA, Jobling AI, Gentle A. Biomechanics of the sclera in myopia: extracellular and cellular factors. Optom Vis Sci. 2009;86(1):E23–30. Epub 2008/12/24. [DOI] [PubMed] [Google Scholar]
  • 4.Troilo D, Smith EL 3rd, Nickla DL, Ashby R, Tkatchenko AV, Ostrin LA, et al. IMI - Report on Experimental Models of Emmetropization and Myopia. Invest Ophthalmol Vis Sci. 2019;60(3):M31–M88. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Grytz R. Scleral remodeling in myopia. In: Biomechanics of the Eye (Roberts C, Dupps WJ, Downs JC, editors). Amsterdam: Kugler Publications, 2018. pp. 383–403. [Google Scholar]
  • 6.McBrien NA, Cornell LM, Gentle A. Structural and ultrastructural changes to the sclera in a mammalian model of high myopia. Invest Ophthalmol Vis Sci. 2001;42(10):2179–87. Epub 2001/08/31. [PubMed] [Google Scholar]
  • 7.Harper AR, Summers JA. The dynamic sclera: extracellular matrix remodeling in normal ocular growth and myopia development. Exp Eye Res. 2015;133:100–11. Epub 2015/03/31. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Phillips JR, Khalaj M, McBrien NA. Induced myopia associated with increased scleral creep in chick and tree shrew eyes. Invest Ophthalmol Vis Sci. 2000;41(8):2028–34. Epub 2000/07/13. [PubMed] [Google Scholar]
  • 9.Jonas JB, Jonas SB, Jonas RA, Holbach L, Panda-Jonas S. Histology of the parapapillary region in high myopia. Am J Ophthalmol. 2011;152(6):1021–9. Epub 20110806. [DOI] [PubMed] [Google Scholar]
  • 10.Friedenwald JS. Contribution to the Theory and Practice of Tonometry. Am J Ophthalmol. 1937;20(10):985–1024. [Google Scholar]
  • 11.Pallikaris IG, Kymionis GD, Ginis HS, Kounis GA, Tsilimbaris MK. Ocular rigidity in living human eyes. Invest Ophthalmol Vis Sci. 2005;46(2):409–14. [DOI] [PubMed] [Google Scholar]
  • 12.Beaton L, Mazzaferri J, Lalonde F, Hidalgo-Aguirre M, Descovich D, Lesk MR, Costantino S. Non-invasive measurement of choroidal volume change and ocular rigidity through automated segmentation of high-speed OCT imaging. Biomed Opt Express. 2015;6(5):1694–706. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Sayah DN, Mazzaferri J, Ghesquiere P, Duval R, Rezende F, Costantino S, Lesk MR. Non-invasive in vivo measurement of ocular rigidity: Clinical validation, repeatability and method improvement. Exp Eye Res. 2020;190:107831. Epub 2019/10/14. [DOI] [PubMed] [Google Scholar]
  • 14.Sayah DN, Mazzaferri J, Descovich D, Costantino S, Lesk MR. The Association Between Ocular Rigidity and Neuroretinal Damage in Glaucoma. Invest Ophthalmol Vis Sci. 2020;61(13):11. Epub 2020/11/06. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Sayah DN, Mazzaferri J, Descovich D, Costantino S, Lesk MR. Ocular rigidity and neuroretinal damage in patients with vasospasticity: a pilot study. Can J Ophthalmol. 2022. Epub 2022/04/01. [DOI] [PubMed] [Google Scholar]
  • 16.Sayah DN, Descovich D, Costantino S, Lesk MR. The Association between the Pulsatile Choroidal Volume Change and Ocular Rigidity. Ophthalmology Science. 2024;4:100576. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Ma Y, Moroi SE, Roberts CJ. Non-invasive Clinical Measurement of Ocular Rigidity and Comparison to Biomechanical and Morphological Parameters in Glaucomatous and Healthy Subjects. Front Med (Lausanne). 2021;8:701997. Epub 20210705. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Sayah DN, Szigiato AA, Mazzaferri J, Descovich D, Duval R, Rezende FA, et al. Correlation of ocular rigidity with intraocular pressure spike after intravitreal injection of bevacizumab in exudative retinal disease. Br J Ophthalmol. 2021;105(3):392–6. Epub 2020/04/30. [DOI] [PubMed] [Google Scholar]
  • 19.Sayah DN. Ocular rigidity : a previously unexplored risk factor in the pathophysiology of open-angle glaucoma : assessment using a novel OCT-based measurement method. 2020.
  • 20.Sayah DN, Descovich D, Costantino S, Lesk MR. The influence of axial length on ocular rigidity in open-angle glaucoma. Invest Ophthalmol Vis Sci. 2023;64(8):58. [Google Scholar]
  • 21.Masis Solano M, Belanger Nzakimuena C, Dumas R, Lesk MR, Costantino S. Ocular rigidity and choroidal thickness changes in response to microgravity: A case study. Am J Ophthalmol Case Rep. 2023;32:101940. Epub 20231007. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Solano MM, Dumas R, Lesk MR, Costantino S. Ocular Biomechanical Responses to Long-Duration Spaceflight. IEEE Open J Eng Med Biol. 2025;6:127–32. Epub 20240905. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.Dastiridou AI, Ginis H, Tsilimbaris M, Karyotakis N, Detorakis E, Siganos C, et al. Ocular rigidity, ocular pulse amplitude, and pulsatile ocular blood flow: the eeect of axial length. Invest Ophthalmol Vis Sci. 2013;54(3):2087–92. Epub 2013/03/07. [DOI] [PubMed] [Google Scholar]
  • 24.Deng L, Gwiazda JE. Anisometropia in children from infancy to 15 years. Invest Ophthalmol Vis Sci. 2012;53(7):3782–7. Epub 20120620. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Hart L. Biometry/Axial Length in Ophthalmic Ultrasound. Journal of Diagnostic Medical Sonography. 1999;15(6):238–42. [Google Scholar]
  • 26.Reyes M, Smith S, Lam K, Adel Y, Patel NB, Sayah DN. The Non-invasive Measurement of Ocular Rigidity and the Pulsatile Choroidal Volume Change in Children and Young Adults. Ophthalmology Science. 2025. Epub April 26, 2025. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Li Y, Bao FJ. Interocular symmetry analysis of bilateral eyes. J Med Eng Technol. 2014;38(4):179–87. Epub 20140415. [DOI] [PubMed] [Google Scholar]
  • 28.Albarran-Diego C, Poyales F, Lopez-Artero E, Garzon N, Garcia-Montero M. Interocular biometric parameters comparison measured with swept-source technology. Int Ophthalmol. 2022;42(1):239–51. Epub 20210821. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.Yuhas PT, McHugh-Morrison C, Canavan J, Jeyandran J, Mahmoud AM, Roberts CJ. Intereye Dieerences in the Clinical Assessment of Intraocular Pressure and Ocular Biomechanics. Optom Vis Sci. 2023;100(10):688–96. Epub 20230829. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 30.McAlinden C, Gao R, Yu A, Wang X, Yang J, Yu Y, et al. Repeatability and agreement of ocular biometry measurements: Aladdin versus Lenstar. Br J Ophthalmol. 2017;101(9):1223–9. Epub 20170127. [DOI] [PubMed] [Google Scholar]
  • 31.Rauscher FG, Hiemisch A, Kiess W, Michael R. Feasibility and repeatability of ocular biometry measured with Lenstar LS 900 in a large group of children and adolescents. Ophthalmic Physiol Opt. 2021;41(3):512–22. Epub 20210327. [DOI] [PubMed] [Google Scholar]
  • 32.Moreno-Montanes J, Maldonado MJ, Garcia N, Mendiluce L, Garcia-Gomez PJ, Segui-Gomez M. Reproducibility and clinical relevance of the ocular response analyzer in nonoperated eyes: corneal biomechanical and tonometric implications. Invest Ophthalmol Vis Sci. 2008;49(3):968–74. [DOI] [PubMed] [Google Scholar]
  • 33.David VP, Stead RE, Vernon SA. Repeatability of ocular response analyzer metrics: a gender-based study. Optom Vis Sci. 2013;90(7):691–9. [DOI] [PubMed] [Google Scholar]
  • 34.Kopito R, Gaujoux T, Montard R, Touzeau O, Allouch C, Borderie V, Laroche L. Reproducibility of viscoelastic property and intraocular pressure measurements obtained with the Ocular Response Analyzer. Acta Ophthalmol. 2011;89(3):e225–30. Epub 20100825. [DOI] [PubMed] [Google Scholar]
  • 35.Zheng X, Bao F, Geraghty B, Huang J, Yu A, Wang Q. High intercorneal symmetry in corneal biomechanical metrics. Eye Vis (Lond). 2016;3:7. Epub 20160305. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Spaide RF, Koizumi H, Pozzoni MC. Enhanced depth imaging spectral-domain optical coherence tomography. Am J Ophthalmol. 2008;146(4):496–500. [DOI] [PubMed] [Google Scholar]
  • 37.Chen FK, Yeoh J, Rahman W, Patel PJ, Tufail A, Da Cruz L. Topographic variation and interocular symmetry of macular choroidal thickness using enhanced depth imaging optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53(2):975–85. Epub 20120223. [DOI] [PubMed] [Google Scholar]
  • 38.Al-Haddad C, El Chaar L, Antonios R, El-Dairi M, Noureddin B. Interocular symmetry in macular choroidal thickness in children. J Ophthalmol. 2014;2014:472391. Epub 20141124. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Lu J, Zhou H, Shi Y, Choe J, Shen M, Wang L, et al. Interocular asymmetry of choroidal thickness and vascularity index measurements in normal eyes assessed by swept-source optical coherence tomography. Quant Imaging Med Surg. 2022;12(1):781–95. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 40.Bhayana AA, Kumawat D, Kumar V, Chandra M, Chandra P, Sihota R, Kumar A. Interocular asymmetry in choroidal thickness in healthy Indian population using swept-source optical coherence tomography. Indian J Ophthalmol. 2019;67(7):1252–3. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 41.Ruiz-Medrano J, Flores-Moreno I, Pena-Garcia P, Montero JA, Duker JS, Ruiz-Moreno JM. Asymmetry in Macular Choroidal Thickness Profile between Both Eyes in a Healthy Population Measured by Swept-Source Optical Coherence Tomography. Retina. 2015;35(10):2067–73. [DOI] [PubMed] [Google Scholar]
  • 42.Manbachi A, Hoi Y, Wasserman BA, Lakatta EG, Steinman DA. On the shape of the common carotid artery with implications for blood velocity profiles. Physiol Meas. 2011;32(12):1885–97. Epub 20111027. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 43.Cui H, Zhang Z. Interocular symmetry and asymmetry in ocular health and disease. Front Med (Lausanne). 2025;12:1626329. Epub 20250923. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 44.Maguire MG. Assessing Intereye Symmetry and Its Implications for Study Design. Invest Ophthalmol Vis Sci. 2020;61(6):27. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data supporting the findings of this study may be made available from the corresponding author upon reasonable request, subject to institutional and ethical approvals.

RESOURCES