ABSTRACT
Maxillary anterior bone loss complicates implant surgery. We adopted a modified abutment plus transmembrane‐fixed GBR for delayed implantation in a 21‐year‐old patient. In this single case, the combined protocol was clinically feasible and associated with favorable short‐term esthetic and functional outcomes.
Keywords: bone augmentation, maxillary central incisor, modified anatomical healing abutment, soft tissue esthetics
Key Clinical Message
In a selected anterior site with facial bone deficiency, delayed implant placement combined with healing‐abutment‐assisted transmembrane‐fixation GBR and a modified anatomic healing abutment was a feasible one‐stage approach for simultaneous hard‐ and soft‐tissue management. Controlled studies are needed before routine recommendation.
1. Introduction
The maxillary central incisor occupies a highly visible position in the anterior dentition. After tooth loss, the facial alveolar ridge may undergo progressive resorption, leaving inadequate horizontal bone volume and a depressed gingival contour. These changes can compromise implant stability, increase the risk of facial implant exposure or mucosal recession, and make a natural restoration difficult to reproduce [1].
Guided bone regeneration (GBR) is widely used to manage localized ridge deficiencies in the esthetic zone. Its success depends not only on the graft material but also on maintaining a stable, protected space beneath the barrier membrane. Membrane displacement, collapse of the regenerative compartment, and insufficient augmentation around the implant neck remain practical concerns [2]. Fixing a collagen membrane through a healing abutment offers a simple way to stabilize the membrane during simultaneous implant placement [3].
Anatomic healing abutments are designed to approximate the cervical form of a natural tooth and can provide a more physiologic emergence profile during peri‐implant soft‐tissue healing [4, 5]. In principle, combining this soft‐tissue support with healing‐abutment‐assisted membrane fixation could address the facial hard‐ and soft‐tissue components of an anterior implant site in one surgical episode. However, clinical descriptions of this combined approach in delayed anterior implantation remain limited. We therefore present the clinical course and 1‐year outcome of a patient treated with a modified anatomic healing abutment, transmembrane fixation, and simultaneous GBR.
Previously reported healing‐abutment‐assisted membrane fixation mainly used conventional circular healing abutments as a mechanical anchor for membrane stabilization [3]. In the present report, the novelty lies in integrating:
Transmembrane fixation (mechanical stabilization of the collagen membrane at implant neck level), and
A custom modified anatomic healing abutment (non‐circular cervical profile intended to guide peri‐implant soft‐tissue emergence), within one delayed‐placement surgery in the maxillary esthetic zone.
Compared with conventional round abutments, this design aims to provide broader facial and interproximal soft‐tissue support while maintaining membrane stability during early healing. This biologic and mechanical dual‐purpose configuration has been less specifically described in delayed maxillary central incisor implantation.
1.1. Design and Fabrication of the Modified Anatomic Healing Abutment
In this study, the target tooth was removed from a standardized precision dentoform model, with the native three‐dimensional gingival contour fully preserved. A Datsing implant scan body was securely fixed to the predetermined implant site using wax sealing (Figure 1a). The assembled model was scanned with a high‐precision 3Shape scanner to generate a precise digital model that integrated gingival morphological features and scan body positional data. The acquired digital files were imported into 3Shape design software and matched to the corresponding Datsing implant digital database. The transmucosal core profile of the healing abutment was designed in accordance with the cervical anatomy of the natural tooth, adopting a 20% dimensional reduction strategy to compensate for physiological peri‐implant bone resorption (Figure 1b). The transmucosal height was standardized at 2–4 mm and optimized into a mild concave surface to mimic natural gingival architecture, ensuring continuous and harmonious transition between the transmucosal and supragingival contours (Figure 1c). Subsequently, the STL design data were transferred to a five‐axis CNC lathe for high‐precision automated machining using Grade 5 titanium alloy (Ti‐6Al‐4V) blanks. After fine grinding and polishing, the customized abutment was assembled with a matched central screw. Strict quality verification was performed via combined 3D optical scanning and contact detection. The final product achieved a dimensional tolerance within ±10 μm, with qualified surface roughness and other morphological indices, completing the standardized digital fabrication workflow (Figure 1d). Compared with conventional stock healing abutments, this modified anatomic abutment exhibits a biomimetic transmucosal morphology that closely adapts to post‐extraction alveolar anatomy. It provides stable mechanical support for peri‐implant soft tissues and GBR membranes, enhances membrane positional stability, and helps maintain an intact physiological soft tissue cuff, thereby optimizing anterior implant red‐white esthetic outcomes (Figure 1e–h). This reduction was selected as a pragmatic design parameter based on (i) reported early horizontal remodeling trends of the facial ridge after extraction [6] and (ii) pilot bench fitting on the model to permit tension‐free flap adaptation while preserving emergence guidance. The 20% reduction should be interpreted as an empirical parameter rather than a universally validated threshold. The abutment was polished to obtain a smooth transmucosal surface, ultrasonically cleaned, and sterilized before surgery.
FIGURE 1.

(a) Occlusal view of a solid maxillary standard dentoform model, with an implant scan body placed at site 11; (b) Occlusal view of the digital model acquired by three‐dimensional scanning.; (c) CAD 3D model of the coronal top surface of the modified anatomic healing abutment; (d) Machining model of the abutment with a holding stem in CAM machining software; (e) Occlusal view:Mesiodistal diameter: 7 mm Buccolingual diameter: 6 mm Screw access hole diameter: 2 mm; (f) frontal view:Height: 11 mm; (g) Modified anatomic healing abutment with its corresponding central screw; (h) Comparison photograph of the modified anatomic healing abutment (left) and conventional healing abutment (right).
2. Case Presentation
2.1. Patient Information and Ethics
A 21‐year‐old man presented in April 2025 with a missing right maxillary central incisor (tooth 11, FDI) for 4 months. The tooth had been extracted at another clinic due to crown‐root fracture after trauma (self‐reported history; no acute infection at referral). The patient requested fixed implant rehabilitation. He was systemically healthy, non‐smoker, with no relevant medication history, allergy, or contraindication to oral surgery. Oral hygiene was acceptable. At site 11, a mild facial soft‐tissue depression was visible. The periodontal phenotype was medium‐to‐thick, and keratinized mucosal width was clinically adequate for flap closure. Adjacent teeth (12, 21) were vital, non‐mobile, and periodontally stable. The treatment plan, alternatives, risks, benefits, and imaging schedule were explained. Written informed consent for treatment and publication was obtained. Ethics approval: fsyy2024022.
2.2. Preoperative Clinical and Radiographic Assessment
Intraoral examination showed an edentulous 11 site with a visible facial soft‐tissue depression. The attached gingiva had normal color and width, without obvious erythema, bleeding, or inflammation. The adjacent teeth (12 and 21) were not mobile and were not tender to percussion. Periodontal probing depths were 2–3 mm, and no clinical attachment loss was detected (Figure 2a,b). CBCT showed a concave facial ridge defect with an approximately 14.0‐mm vertical bone height and 4.2‐mm horizontal ridge width. The facial bone plate was thin, but no abnormal radiodensity, resorptive lesion, or destructive change was identified (Figure 2c). The site was considered suitable for implant placement with simultaneous facial augmentation.
FIGURE 2.

Preoperative assessment. (a) Frontal intraoral view; (b) occlusal view; (c) sagittal CBCT image showing a horizontal ridge width of 4.2 mm and a vertical bone height of 14.0 mm at the tooth 11 site.
CBCT examinations were performed (LargeV Smart3D‐Xs) in the standing position. Standardized positioning was performed via the built‐in cephalometric system with cross‐hair lasers, motorized headrest, and positioning mirror. Uniform scanning parameters: standard‐dose mode, 100 kV tube voltage, 6.0 mA tube current, 15 cm × 10 cm FOV, 12.5 s acquisition time, DAP of 191.51 μGy·m2. Measurements were performed in sagittal cross‐sections passing through the implant long axis (postoperative/follow‐up) or the center of the edentulous ridge (preoperative). Labial hard‐tissue thickness was measured perpendicular to the implant axis (or planned axis preoperatively) at three levels:
Shoulder level: implant platform level
Midpoint level: midpoint between shoulder and apex
Apical level: implant apex level
Each measurement was repeated three times by one calibrated examiner at a 2‐week interval; mean values were recorded. These radiographic values are imaging‐based morphologic observations and do not constitute histologic proof of new bone formation. All CBCT measurements were performed by a single examiner using the predefined standardized measurement protocol. Because only one examiner performed the measurements, interobserver reliability was not assessed.
2.2.1. Rationale for Serial CBCT
Serial CBCT examinations were undertaken as part of the clinical follow‐up protocol, when clinically appropriate, to assess dimensional stability and support decisions regarding restorative timing. The need for and frequency of imaging were discussed with the patient in relation to radiation exposure, and each examination was performed using the lowest radiation exposure clinically appropriate.
2.3. Surgical Procedure
2.3.1. Preoperative Preparation
Routine laboratory testing, including a complete blood count, coagulation profile, and hepatitis B serology, was performed to exclude contraindications to surgery. The patient was instructed to rinse with a compound chlorhexidine solution for 3 days before surgery. Thirty minutes before the procedure, the surgical site was disinfected with povidone‐iodine, and a sterile drape was applied.
2.3.2. Implant Placement, GBR, and Transmembrane Fixation
Under local anesthesia (4% articaine with epinephrine 1:100,000), a mid‐crestal incision with one distal vertical release was made. A full‐thickness mucoperiosteal flap was elevated to expose the facial defect (Figure 3a). Minimal periosteal releasing incisions were performed for passive coronal repositioning. Osteotomy was prepared according to the implant protocol under copious sterile saline irrigation. A bone‐level implant (Datsing, 4.0 × 10.0 mm) was placed with insertion torque 35 N·cm. Implant 3D position was prosthetically driven (palatalized shoulder position, appropriate depth for anterior emergence profile) (Figure 3b). A Bio‐Gide collagen membrane was trimmed to extend at least 2–3 mm beyond the defect margins. A central perforation matching the abutment transmucosal diameter was made. The membrane was passed over the modified anatomic healing abutment and stabilized at the implant neck by tightening the abutment to 15 N·cm (transmembrane fixation) (Figure 3c). Facial cortical decortication (multiple 0.8–1.0 mm bleeding points) was performed prior to graft placement. Deproteinized bovine bone mineral (Bio‐Oss, small granules 0.25–1.0 mm) was hydrated and packed incrementally into the facial defect without overcompression, reconstructing physiologic convexity and overbuilding approximately 1–2 mm to compensate expected remodeling (Figure 3d). Membrane margins were tucked under the buccal and palatal flaps. Primary closure without tension was achieved using 4–0 absorbable interrupted and sling sutures (Figure 3e). Postoperative CBCT showed labial bone plate thicknesses of 2.6, 3.6, and 3.5 mm at the implant shoulder, midpoint, and apex, respectively (Figure 3f).
FIGURE 3.

Surgical procedure. (a) Flap elevation and exposure of the facial bone defect; (b) osteotomy preparation and implant placement; (c) fixation of the perforated Bio‐Gide membrane with the modified anatomic healing abutment; (d) facial cortical decortication and graft placement; (e) wound closure; (f) postoperative CBCT measurement of labial bone plate thickness at the implant shoulder, midpoint, and apex (2.6, 3.6, and 3.5 mm, respectively).
2.4. Postoperative Management and Follow‐Up
The patient received oral amoxicillin combined with metronidazole for 3 days, ibuprofen as needed for pain, and chlorhexidine rinses for 1 week. Local cold compresses were recommended during the first 24 h. The patient was instructed to avoid hard or very hot food and not to chew at the surgical site. Sutures were removed at 7 days, and subsequent examinations were scheduled at regular intervals.
At 1 and 3 months, the gingival contour at the edentulous site was full, the facial depression had resolved, and no gingival recession or clinical inflammation was observed (Figures 4a,b and 5a,b). CBCT measurements at the implant shoulder, midpoint, and apex were 2.4, 3.5, and 3.4 mm at 1 month, respectively, and 2.0, 3.0, and 3.1 mm at 3 months, respectively (Figures 4c and 5c).
FIGURE 4.

One‐month follow‐up. (a) Frontal intraoral view; (b) occlusal view; (c) sagittal CBCT image showing labial bone plate thicknesses of 2.4, 3.5, and 3.4 mm at the implant shoulder, midpoint, and apex, respectively.
FIGURE 5.

Three‐month follow‐up. (a) Frontal intraoral view; (b) occlusal view; (c) sagittal CBCT image showing labial bone plate thicknesses of 2.0, 3.0, and 3.1 mm at the implant shoulder, midpoint, and apex, respectively.
At the 6‐month visit, the gingival cuff was well formed, the interproximal papillae were fully developed, and the gingival margin was symmetric without recession, erythema, or suppuration (Figure 6a,b). An intraoral digital scan was used to record the peri‐implant soft tissues and adjacent teeth. A customized abutment and a zirconia all‐ceramic crown were fabricated. Occlusion, proximal contacts, and crown morphology were adjusted clinically to eliminate interference in centric and lateral movements. The crown shade and translucency were selected to harmonize with the neighboring teeth, and the crown was permanently cemented with glass ionomer cement. CBCT showed maintained peri‐implant radiographic bone contours in the grafted region; labial bone plate thicknesses at the shoulder, midpoint, and apex were 1.8, 2.6, and 2.7 mm, respectively (Figure 6c).
FIGURE 6.

Six‐month follow‐up and definitive restoration. (a) Frontal view after crown delivery; (b) occlusal view; (c) sagittal CBCT image showing labial bone plate thicknesses of 1.8, 2.6, and 2.7 mm at the implant shoulder, midpoint, and apex, respectively.
At the 1‐year follow‐up, mastication and speech had fully recovered. Implant success/osseointegration was clinically judged by: absence of pain/spontaneous symptoms, absence of implant mobility on bidirectional instrument testing, no peri‐implant suppuration, probing depth 2–3 mm without bleeding on probing, and stable peri‐implant crestal radiographic appearance without progressive radiolucency.
The Pink Esthetic Score (PES) was 10 (Table 1). The gingival margin was level with the adjacent teeth, the papillae were complete, and neither a black triangle nor gingival recession was present (Figure 7a,b). CBCT showed a stable peri‐implant radiographic appearance at the one‐year follow‐up (Figure 7c). The patient reported a satisfaction score of 9.8 and no postoperative discomfort (Table 2).
TABLE 1.
Pink Esthetic Score (PES) at 1‐year follow‐up.
| PES variable | Absent (0) | Incomplete (1) | Complete (2) | Case score | Notes |
|---|---|---|---|---|---|
| Mesial papilla | 0 | 1 | 2 | 2 | Complete papilla fill |
| Distal papilla | 0 | 1 | 2 | 2 | Complete papilla fill |
| Labial gingival curve | 0 | 1 | 2 | 1 | Slight irregularity of the labial gingival curve |
| Position of the zenith of labial gingival margin | 0 | 1 | 2 | 1 | Slight deviation of the zenith position |
| Root convexity | 0 | 1 | 2 | 1 | Mild loss of root convexity |
| Soft tissue color | 0 | 1 | 2 | 1 | Mild color difference from adjacent dentition |
| Soft tissue texture | 0 | 1 | 2 | 2 | Texture consistent with adjacent dentition |
| Total PES score | — | — | 14 | 10 | — |
Note: PES criteria according to Fürhauser et al. PES was scored independently by two prosthodontists based on standardized frontal photographs; discrepancies were resolved by consensus. Total score range 0–14.
FIGURE 7.

One‐year follow‐up. (a) Frontal view; (b) occlusal view; (c) sagittal CBCT image showing labial bone plate thicknesses of 1.7, 2.5, and 2.6 mm at the implant shoulder, midpoint, and apex, respectively.
TABLE 2.
10‐cm Visual Analog Scale (VAS) patient‐reported satisfaction at 1‐year follow‐up.
| Item | Maximum score | Observed score | Notes |
|---|---|---|---|
| Esthetics | 10 | 9.5 | Subjective appearance of restoration and peri‐implant gingiva |
| Comfort | 10 | 10 | Absence of pain, foreign‐body sensation or irritation |
| Function | 10 | 9.9 | Masticatory performance and occlusal comfort |
| Overall VAS satisfaction score | 10 | 9.8 | Global patient‐reported outcome |
Note: VAS consisted of a 10‐cm horizontal scale (0 = completely dissatisfied; 10 = completely satisfied). The patient marked a vertical line for each domain; scores correspond to measured distance from the zero anchor.
3. Discussion
The facial cortical plate in the maxillary anterior region is thin, and ridge resorption after tooth loss can rapidly create a horizontally deficient site. Implant placement without augmentation may therefore lead to facial implant exposure, soft‐tissue recession, and an unsatisfactory esthetic result [7, 8]. GBR is intended to exclude soft tissue from the regenerative compartment and maintain the space needed for bone formation; however, conventional membrane fixation may be vulnerable to displacement, collapse, or exposure, with subsequent contamination of the graft material [9]. The central membrane opening was created to accommodate the healing abutment and permit stabilization of the collagen membrane around it. This opening should not be interpreted as intentional precision microperforation designed to enhance membrane permeability. Although membrane structure and configuration may theoretically influence fluid exchange, nutrient diffusion, and vascularization, these potential effects were not assessed in the present case.
The CBCT observations indicated maintenance of the peri‐implant facial contour and radiographic changes in the augmented region during follow‐up. However, CBCT cannot determine the histologic nature, maturity, or degree of regeneration of the observed tissue. Traditional membrane‐fixation strategies using tacks or screws anchor barrier membranes on peripheral bone. This technique may produce uneven membrane tension and local wrinkling. Furthermore, these rigid fixation devices require additional bone penetration, which adds surgical trauma and may increase risks of postoperative inflammation and membrane exposure. The transmembrane fixation described in the present case avoids bone‐penetrating hardware. It provides a central anchoring point at the implant neck level and may simplify surgical manipulation, though comparative clinical evidence is still lacking [10, 11, 12].
In the present case, the healing abutment served as a central fixation point for the collagen membrane while the implant was placed. The membrane was positioned around the implant neck, and the excess was tucked beneath the reflected flaps. This configuration appeared to maintain a stable regenerative space and to support circumferential bone formation around the cervical implant region. From the immediate postoperative examination to the 1‐year visit, the reductions in labial bone plate thickness at the shoulder, midpoint, and apex were 0.9, 1.1, and 0.9 mm, respectively. These measurements are descriptive observations from a single case and should not be interpreted as evidence of superiority over conventional GBR. Serial CBCT showed dimensional maintenance trends of labial hard‐tissue contour, but these radiographic findings should be described as morphologic changes only. They cannot confirm histologic quality or true regeneration pattern. The favorable outcome observed in this case should not be attributed solely to the modified anatomic healing abutment or the transmembrane‐fixation approach. It may also reflect appropriate case selection, careful implant positioning, simultaneous guided bone regeneration, effective wound management, and postoperative maintenance. The proposed technique should therefore be regarded as a technical modification that may facilitate membrane stabilization and peri‐implant contour management, rather than as evidence of a biologically superior regenerative method. Controlled clinical studies with larger samples and longer follow‐up are required to determine its potential advantages and indications.
The modified anatomic healing abutment was intended to control the peri‐implant emergence profile during soft‐tissue maturation. A cervical contour that approximates the natural tooth may provide more even support to the facial mucosa and interproximal papillae than a conventional circular healing abutment. Clinical and review literature suggests that abutment morphology can influence peri‐implant hard‐tissue behavior, although the effect on soft‐tissue esthetics remains less certain [13]. In this patient, the favorable gingival contour, complete papillae, absence of recession, and PES of 10 support the clinical plausibility of the approach, but they cannot establish a causal effect.
Delayed implant placement was selected because it avoided the strict requirements associated with immediate placement in a fresh extraction socket and allowed the facial defect and soft‐tissue condition to be assessed before implant surgery. Delayed placement may be more controllable when the ridge has already collapsed or when the facial soft‐tissue phenotype is unfavorable, although the available evidence does not support a universal preference for one timing protocol [14]. In this case, the combination of delayed placement, transmembrane‐fixation GBR, and an anatomic healing abutment integrated hard‐tissue augmentation and soft‐tissue shaping in a single surgical protocol.
This report has important limitations. It describes only one patient, lacks a comparator, and provides a 1‐year follow‐up. CBCT measurements may also be affected by image resolution, slice selection, and measurement reproducibility. The observed outcome should therefore be regarded as preliminary. Larger prospective studies should use standardized three‐dimensional measurements, validated esthetic indices, patient‐reported outcomes, and longer follow‐up to determine the reproducibility and durability of this technique.
4. Conclusion
Within the limitations of this single case, delayed maxillary central incisor implantation with simultaneous GBR, healing‐abutment‐assisted transmembrane fixation, and a modified anatomic healing abutment was a practicable approach and was associated with favorable 1‐year clinical and esthetic outcomes. These preliminary observations require validation in controlled studies before routine clinical adoption.
Author Contributions
Jian Ma: investigation, writing – original draft, validation, data curation. Wenchao Li: conceptualization, project administration, resources, supervision, writing – review and editing.
Funding
This work was supported by Inner Mongolia Science and Technology Plan Project, 2026YFSH0047.
Ethics Statement
The case was approved by the institutional ethics committee (approval no. fsyy2024022).
Consent
Written informed consent was obtained from the patient for the publication of this case report.
Conflicts of Interest
The authors declare no conflicts of interest.
Acknowledgments
We acknowledge the support from the Inner Mongolia Science and Technology Plan Project (2026YFSH0047).
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.
References
- 1. Chen Y. Y., Wu W. L., and Shen M., “Imaging Measurements and Analysis Related to Esthetic Implants in the Maxillary Incisor Region,” Journal of Stomatology 44, no. 6 (2024): 421–425. [in Chinese]. [Google Scholar]
- 2. Wang M. J. and Deng Y., “Analysis of Resorption and Contributing Factors of Labial Cervical Bone Augmentation Materials Around Implants After Guided Bone Regeneration in the Anterior Region,” Chinese Journal of Oral Implantology 27, no. 3 (2022): 156–160. [in Chinese]. [Google Scholar]
- 3. Kwon T. K., Kang Y. H., and Byun J. H., “Membrane Fixation Using Healing Abutment During Guided Bone Regeneration: A Report of Two Cases,” Journal of Implantology and Applied Sciences 26, no. 2 (2022): 120–127, 10.32542/implantology.2022011. [DOI] [Google Scholar]
- 4. Yu H. Y., Changes in Hard and Soft Tissues After Use of a Modified Anatomic Healing Abutment in a Maxillary Central Incisor [Dissertation] (Inner Mongolia Medical University, 2025). [in Chinese]. [Google Scholar]
- 5. Berkei G. and Vág J., “Peri‐Implant Soft Tissue Conditioning With Prefabricated Titanium Anatomic Healing Abutment Compared With Conventional Circular Healing Abutment: A Case Letter,” Journal of Oral Implantology 48, no. 6 (2022): 523–532, 10.1563/aaid-joi-D-21-00272. [DOI] [PubMed] [Google Scholar]
- 6. Tan W. L., Wong T. L., Wong M. C., and Lang N. P., “A Systematic Review of Post‐Extraction Alveolar Ridge Dimensional Changes,” Clinical Oral Implants Research 23, no. 11 (2012): 1270–1283. [DOI] [PubMed] [Google Scholar]
- 7. Mazzotti C., Stefanini M., Felice P., Bentivogli V., Mounssif I., and Zucchelli G., “Soft‐Tissue Dehiscence Coverage at Peri‐Implant Sites,” Periodontology 2000 77, no. 1 (2018): 256–272, 10.1111/prd.12220. [DOI] [PubMed] [Google Scholar]
- 8. Sanz‐Martín I., Regidor E., Navarro J., Sanz‐Sánchez I., Sanz M., and Ortiz‐Vigón A., “Factors Associated With the Presence of Peri‐Implant Buccal Soft Tissue Dehiscences: A Case‐Control Study,” Journal of Periodontology 91, no. 8 (2020): 1003–1010, 10.1002/JPER.19-0490. [DOI] [PubMed] [Google Scholar]
- 9. de Azambuja Carvalho P. H., dos Santos Trento G., Moura L. B., Cunha G., Gabrielli M. A. C., and Pereira‐Filho V. A., “Horizontal Ridge Augmentation Using Xenogenous Bone Graft‐Systematic Review,” Oral and Maxillofacial Surgery 23, no. 3 (2019): 271–279, 10.1007/s10006-019-00777-y. [DOI] [PubMed] [Google Scholar]
- 10. Suchenski M., Goenka A., and Patel A., “Barrier Membrane Fixation in Guided Bone Regeneration: A Review of Current Materials and Techniques,” Journal of Oral Implantology 47, no. 3 (2021): 230–238, 10.1563/aaid-joi-D-19-00240. [DOI] [Google Scholar]
- 11. Park J. H., Lee J. H., and Kim Y. K., “Mechanical Stability of Resorbable Collagen Membranes According to Different Fixation Methods,” Journal of Clinical Periodontology 47, no. S1 (2020): 112–118, 10.1111/jcpe.13245. [DOI] [Google Scholar]
- 12. Chappuis V., Cordaro L., and Bosshardt D. D., “Complications of Guided Bone Regeneration: Risk Factors and Management,” International Journal of Oral & Maxillofacial Implants 33, no. Suppl (2018): S45–S58, 10.11607/jomi.18.s1.7. [DOI] [Google Scholar]
- 13. Canullo L., Pesce P., Patini R., Antonacci D., and Tommasato G., “What Are the Effects of Different Abutment Morphologies on Peri‐Implant Hard and Soft Tissue Behavior? A Systematic Review and Meta‐Analysis,” International Journal of Prosthodontics 33, no. 3 (2020): 297–306, 10.11607/ijp.6577. [DOI] [PubMed] [Google Scholar]
- 14. Garcia‐Sanchez R., Dopico J., Kalemaj Z., Buti J., Pardo Zamora G., and Mardas N., “Comparison of Clinical Outcomes of Immediate Versus Delayed Placement of Dental Implants: A Systematic Review and Meta‐Analysis,” Clinical Oral Implants Research 33, no. 3 (2022): 231–277, 10.1111/clr.13892. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The data that support the findings of this study are available from the corresponding author upon reasonable request.