Abstract
Partial‐thickness subscapularis tears are frequently underdiagnosed, and optimal management remains controversial. Bioinductive collagen implants have shown promising results in partial‐thickness superior rotator cuff tears but have not been described for partial subscapularis pathology. This Technical Note describes a simple arthroscopic technique for bioinductive collagen implant repair or augmentation of partial‐thickness subscapularis tears. This approach provides a reproducible biologic option for managing partial‐thickness subscapularis tears while minimizing technical complexity.

Partial‐thickness subscapularis tears, often involving the upper one‐third border of the tendon, are frequently missed on both magnetic resonance imaging and diagnostic arthroscopy. 1 , 2 The reported incidence of a subscapularis tear combined with other tears of the rotator cuff is estimated to be between 19% and 49%; 3 however, management of partial subscapularis tears remains controversial, with 38.3% of American Shoulder and Elbow Surgeons members recommending repair in partial upper one‐third subscapularis tears in a recent survey study. 4 Importantly, magnetic resonance imaging studies examining subscapularis tear progression in partial tears treated nonoperatively show progression of tears over the course of several years. 5 , 6 Additionally, a recent prospective randomized trial found no difference in patient‐reported outcomes (PROs) between arthroscopic repair and debridement for partial subscapularis tears, although repair was associated with greater subscapularis strength. 7 These studies highlight the need for consensus guidelines among surgeons regarding management of partial tears of the subscapularis.
The popularity of bioinductive collagen implants in the treatment of rotator cuff tears has grown exponentially over the last several years with the recent strong recommendation from the American Academy of Orthopaedic Surgeons Clinical Practice Guideline. 8 Studies examining the use of bioinductive collagen implants in augmentation of full‐thickness rotator cuff repairs have shown promising results, with radiographic, histologic, and PROs improved with the bioinductive implant. 9 , 10 , 11 Treatment of partial‐thickness rotator cuff tears with bioinductive collagen implants has also shown improved PROs at 6 weeks, 6 months, and 1 year. 9 , 11 , 12 A prospective study examining isolated repair of partial‐thickness supraspinatus tears with a bioinductive collagen implant showed statistically and clinically improved mean American Shoulder Elbow Surgeons scores and Constant‐Murley Shoulder scores at 1 and 2 years postoperatively, in addition to improved tendon appearance on magnetic resonance imaging. 13 The role of bioinductive collagen implants in partial‐thickness subscapularis tears remains unknown.
To date, there are few technique papers describing bioinductive collagen implants for subscapularis tears. Alkhateeb et al. described a technique using a bioinductive type I collagen material, REGENETEN (Smith+Nephew, Andover, MA), as an augment after a repair of a full‐thickness subscapularis tear in the revision setting. 14 Additionally, Pupa et al. describe tips and tricks in augmenting rotator cuff repair with a bioinductive collagen implant in a recent Technical Note. 15 Other techniques described in the literature include use during anatomic total shoulder arthroplasty 16 for open subscapularis repair after prosthesis implantation. The present Surgical Technique describes a simple arthroscopic technique for repairing or augmenting the repair of partial‐thickness subscapularis tendon tears.
SURGICAL TECHNIQUE
The technique is described in Video 1.
VIDEO 1.
Technique presentation of an arthroscopic repair of an upper border partial‐thickness subscapularis tear using a bioinductive collagen implant. Video content can be viewed at https://doi.org/10.1002/atn2.70381.
Patient Positioning and Preoperative Setup
General anesthesia is used with a preoperative regional block. The patient is positioned in the beach‐chair position per the senior author's preference; however, a lateral decubitus position may also be used. Sequential compressive devices are applied to the lower extremities, and bony prominences are well padded. The patient is brought to the edge of the table on the ipsilateral side with a cushion beneath the legs. An examination under anesthesia is performed to assess range of motion and contractures prior to beginning the procedure. An articulating limb positioner (SPIDER2 Limb Positioner; Smith+Nephew) is used to control positioning of the arm throughout the case.
Portal Placement
The posterior portal is created 1 to 2 cm inferior and medial to the posterolateral corner of the acromion. The joint is insufflated with a spinal needle from this location with 20 cc of saline prior to beginning the arthroscopy. The trocar is used to enter the glenohumeral joint, and a standard diagnostic arthroscopy is performed with a 30° arthroscope. After needle localization with direct visualization, an anterior portal is created in the rotator interval lateral to the coracoid process. For this technique, the trajectory of the anterior portal should allow for perpendicular access to the subscapularis. A 7‐mm twist‐in cannula is initially placed (Arthrex, Naples, FL). An accessory anterolateral portal is then localized with a spinal needle (Figure 1). The location of the accessory anterolateral portal is typically 2 cm distal and 1 to 2 cm lateral to the anterolateral edge of the acromion. When evaluating the accessory anterolateral portal position, it is critical that the spinal needle trajectory is just anterior to the subscapularis and parallel to its fibers (Figure 2). After confirming the spinal needle position, the accessory anterolateral portal is created, and a small cannula is placed if desired for suture management for a primary repair.
FIGURE 1.

Portal localization for the accessory anterolateral portal. The right shoulder is shown in the beach‐chair position with standard surface landmarks outlined. The palpable borders of the acromion, distal clavicle, acromioclavicular joint, and coracoid are marked prior to incision. The 30° arthroscope is in the posterior portal, and a twist‐in cannula is in the anterior portal. A spinal needle is used to localize the accessory anterolateral portal, which is typically 1 to 2 cm lateral and 2 cm distal to the anterolateral border of the acromion.
FIGURE 2.

Intra‐articular localization of the accessory anterolateral working portal using outside‐in localization. Arthroscopic view from a standard posterior portal of a right shoulder in the beach‐chair position. An 18‐gauge spinal needle is used to establish an accessory anterolateral portal (as seen in Figure 1) to optimize trajectory. The needle is visualized entering just superior to the subscapularis tendon and parallel to it, allowing appropriate access for bioinductive implant placement. Once appropriate position and trajectory are confirmed, an incision can be made, and a working cannula can be placed in the accessory anterolateral portal.
Preparation and Evaluation of the Subscapularis
Using a probe through the anterior portal, the long head of the biceps tendon is evaluated. If there are signs of tearing, inflammation, or subluxation, a biceps tenodesis or tenotomy may be performed per surgeon preference. A rotator interval debridement is performed to best evaluate the subscapularis as it inserts onto the lesser tuberosity. Care is taken to preserve the comma tissue as possible. The subscapularis is then evaluated through range of motion, including a posterior lever push maneuver.
Subscapularis Anchor‐Based Repair
If the surgeon prefers, based on the tear pattern, a primary subscapularis repair may be performed using anchors and standard techniques after the lesser tuberosity footprint is prepared. The senior author prefers a 2.6 mm double‐loaded all‐suture anchor for fixation of upper one‐third subscapularis tendon tears (double‐loaded knotless 2.6 FiberTak Anchor; Arthrex).
Subscapularis Repair With Bioinductive Collagen Implant—Implant Insertion and Positioning
Either in isolation or after an anchor‐based repair of the partial‐thickness subscapularis tendon tear, attention is turned to the bioinductive collagen implant repair of the subscapularis tendon. The anterior cannula is exchanged for the tendon anchor cannula (Smith+Nephew). The suture management cannula is removed from the accessory anterolateral portal, and a switching stick or blunt trocar is used to ensure there is adequate working space without soft tissue restriction. For this repair, the senior author more routinely uses a 30° arthroscope, but a 70° arthroscope may be used if preferred or if visualization is difficult. The REGENETEN implant is then guided into the shoulder using the inserter (Figure 3). For most subscapularis repairs, we find that the medium‐sized implant is of sufficient size. As the implant is inserted, care should be taken to remain parallel to the subscapularis tendon. The implant should be placed such that the lateral aspect of the implant overlies the insertion on the lesser tuberosity. Additionally, the superior‐most portion of the implant is placed such that it can be rolled over the upper border of the subscapularis.
FIGURE 3.

Inserting the bioinductive implant through the accessory anterolateral portal. External view of a right shoulder in the beach‐chair position showing instrumentation for delivery of the bioinductive implant. The tendon anchor cannula is in the anterior portal in the rotator interval, and the accessory anterolateral portal is used to optimize trajectory for implant deployment. The bioinductive implant inserter is introduced through the accessory anterolateral portal, allowing a parallel trajectory in relation to the subscapularis and facilitating controlled graft placement and fixation. Proper portal spacing and trajectories are critical to avoid instrument crowding and ensure accurate implant positioning.
Subscapularis Repair With Bioinductive Collagen Implant—Securing the Implant
Once the implant is appropriately positioned, the implant is secured using the poly‐L/D‐lactic acid tendon anchors (Smith+Nephew) through the anterior cannula. The anchors are loaded onto the anchor insertion device using the provided anchor puck. The tendon anchors are placed into the body of the subscapularis tendon initially to hold its position (Figure 4). The anchors are inserted and gentle downward pressure is applied to the insertion device to pierce the implant and the subscapularis, and the anchor is deployed. Multiple anchors are deployed in this fashion. Once the implant is felt to be preliminarily secured, the inserter device is removed by bringing the operative hand more posteriorly and pulling laterally. The anterior cannula may also be used to help stabilize the implant during inserter removal. Then, a probe is inserted through the accessory anterolateral cannula to roll the implant along the upper border of the subscapularis (Figure 5). Tendon anchors are then placed on the upper border in similar technique, taking care to remain perpendicular to the tendon and implant. The arm may be gently rotated or flexed to improve the trajectory of tendon anchors for optimal security. The senior author does not routinely use the provided bone anchors, although these may also be used.
FIGURE 4.

Arthroscopic deployment and fixation of a bioinductive tendon implant. Arthroscopic view from a posterior portal of a right shoulder. A tendon anchor cannula is placed through the anterior portal. The implant inserter is introduced via the accessory anterolateral portal and used to deploy the bioinductive collagen implant onto the subscapularis tendon surface. Fixation is achieved with poly‐L/D‐lactic acid tendon staples, securing the implant to the underlying cuff tissue and footprint. Proper alignment of the delivery cannula and implant inserter facilitates controlled deployment and stable fixation while maintaining visualization of surrounding structures.
FIGURE 5.

Arthroscopic contouring of the bioinductive implant around the superior border of the subscapularis. Arthroscopic view from a posterior portal of a right shoulder. After implant deployment, initial fixation, and inserter removal, an arthroscopic probe is used to manipulate and contour the bioinductive implant around the superior border of the subscapularis tendon ahead of final anchor fixation of the superior border. This maneuver allows the implant to conform to the native tendon surface, optimizing implant‐tendon contact and facilitating secure fixation. Poly‐L/D‐lactic acid tendon anchors are visible, maintaining implant stability during final positioning.
The camera can then be switched to the accessory anterolateral portal (Figure 6A) or even the anterior portal (Figure 6B) to confirm appropriate implant placement and security. The key steps of the procedure are recapped in Table 1. Pearls and pitfalls are described in Table 2. The advantages and disadvantages of this technique are summarized in Table 3. The remainder of the procedure is then carried out in standard fashion, and the portals are closed at the end of the case.
FIGURE 6.

Accessory visualization of the bioinductive implant positioning over the subscapularis. Arthroscopic images of a right shoulder showing final positioning after fixation of a bioinductive implant over the superior border of the subscapularis tendon. (A) View from the accessory anterolateral portal showing the implant draped over the upper subscapularis. This trajectory highlights the anterior cuff coverage achieved with the accessory portal. (B) Corresponding view from the anterior portal showing the implant contouring along the upper border of the subscapularis footprint. Multiple viewing angles confirm circumferential implant coverage and stable fixation atop the subscapularis.
TABLE 1.
Key Steps of Arthroscopic Bioinductive Implant Repair or Augmentation of Partial‐Thickness Subscapularis Tears
| Step | Surgical Phase | Technical Action |
|---|---|---|
| 1 | Diagnostic evaluation | Evaluate the long head of the biceps tendon via the anterior portal; address concomitant biceps pathology with tenodesis or tenotomy as indicated |
| 2 | Exposure | Perform a rotator interval debridement to visualize subscapularis insertion while preserving comma tissue |
| 3 | Tear assessment | Assess the subscapularis through range of motion, including with a posterior lever push maneuver |
| 4 | Primary repair (optional) | Perform an anchor‐based subscapularis repair if indicated after preparing lesser tuberosity footprint |
| 5 | Portal and cannula preparation | Exchange the anterior cannula for the tendon anchor cannula; clear the accessory anterolateral portal path using switching stick or trocar |
| 6 | Implant insertion | Insert REGENETEN bioinductive implant (typically medium size for the subscapularis) through the anterior cannula, maintaining an orientation parallel to the subscapularis |
| 7 | Implant positioning | Position the implant with its lateral edge over the lesser tuberosity footprint and its superior edge draped over the upper subscapularis border |
| 8 | Initial fixation | Secure the implant to the subscapularis tendon using poly‐L/D‐lactic acid tendon anchors through anterior cannula |
| 9 | Implant inserter removal | Remove the implant inserter after preliminary fixation by light posterior translation and withdrawal and use the anterior cannula for stabilization of the implant if necessary |
| 10 | Superior border fixation | Roll the implant over the upper subscapularis border using probe; place additional tendon anchors along the superior margin |
| 11 | Optimization | Gently rotate or flex arm to improve anchor trajectory and fixation |
| 12 | Final assessment | Switch the camera to accessory anterolateral or anterior portal to confirm implant position and stability; a 70° arthroscope may also be used |
TABLE 2.
Pearls and Pitfalls of Arthroscopic Bioinductive Implant Repair or Augmentation of Partial‐Thickness Subscapularis Tears
| Pearls | Pitfalls |
|---|---|
| Perform an extensive debridement of the rotator interval tissue to improve visualization and ease of implantation | Limited rotator interval debridement may contribute to postoperative stiffness |
| Ensure that the anterior portal can lead to perpendicular trajectories to the subscapularis | Poor anterior portal trajectory may make securing the implant with the poly‐L/D‐lactic acid staples more challenging |
| Ensure that the accessory anterolateral portal has a trajectory directly parallel to the subscapularis and is just anterior to it | Poor accessory anterolateral portal trajectory may make placement of the implant more challenging |
| Position the implant such that its lateral border is over the insertion of the subscapularis over the lesser tuberosity | Medializing the implant may limit the healing response at the insertion site where tears are typically located |
| Position the implant such that its upper border can be rolled along the upper border of the subscapularis | Placing the implant too low may limit healing response at the commonly torn upper border and placing the implant too high may generate an excessive response in the rotator interval |
| Secure the implant with multiple tendon staples with firm pressure | Inadequate security of the implant may increase displacement or may result in tendon anchors improperly seating |
| View the implant from multiple trajectories, rotate the shoulder, or use a 70° arthroscope as necessary to ensure proper security and placement | Poor visualization can lead to suboptimal implant placement or security |
TABLE 3.
Advantages and Disadvantages of Arthroscopic Bioinductive Implant Repair or Augmentation of Partial‐Thickness Subscapularis Tears
| Advantages | Disadvantages |
|---|---|
| Provides a reproducible, all‐arthroscopic biologic option for augmentation or isolated repair of partial‐thickness subscapularis tears | Excessive immunologic response may contribute to postoperative pain and stiffness |
| May augment regeneration of host collagen and increase tendon thickness, theoretically decreasing tension across the repair 20 | Implant cost and availability may limit use in some practice settings |
| Can augment technically demanding arthroscopic primary subscapularis repair | Long‐term implant durability and use in subscapularis repairs has not been well established |
| The procedure is relatively quick and efficient | Additional portals may be required depending on standard subscapularis repair techniques |
Postoperative Rehabilitation
The arm is placed into a shoulder immobilizer postoperatively prior to awakening the patient from anesthesia. Postoperative rehabilitation is dictated by additional concomitant procedures, such as repair of the supraspinatus/infraspinatus, biceps tenodesis, or distal clavicle excision, per surgeon preference.
DISCUSSION
Arthroscopic management of subscapularis tears can be technically difficult to manage because of the limited arthroscopic working space and adjacent anatomy. 17 The technique shown represents a reproducible approach to augmentation of partial‐thickness subscapularis tears with a bioinductive collagen implant. To date, there have been limited technique descriptions of arthroscopic bioinductive augmentation for subscapularis tears, with only one paper describing its use in a revision setting for a full‐thickness tear. 14 Several papers describe repair with augmentation in an open setting, specifically in chronic subscapularis tears 18 with synthetic degradable polyurethanurea mesh during anatomic total shoulder arthroplasty. 16 However, there are limited techniques described for arthroscopic bioinductive implant augmentation of partial‐thickness subscapularis tears.
The popularity of bioinductive implants for treatment of partial‐thickness rotator cuff tears continues to grow with radiographic, histologic, and clinical outcomes showing positive results. 19 , 20 , 21 A recent systematic review of 7 clinical studies evaluating bioinductive collagen patch augmentation in partial‐thickness rotator cuff tears showed improved American Shoulder Elbow Surgeons scores across 5 studies, with 3 studies showing 79% to 100% of patients met or exceeded the minimal clinically important difference in 1 to 2 years. 22 Bushnell et al. in a prospective study evaluating treatment of partial‐thickness rotator cuff tears with a bioinductive collagen implant, specifically examined patients undergoing isolated bioinductive repair (IBR) versus takedown of the tear and repair with bioinductive augmentation. 9 Both groups showed improvement in all PROs at 1 year, with the IBR group showing significantly improved PROs at 2 and 6 weeks comparatively. Given the technical difficulty of subscapularis repairs, these studies suggest that isolated bioinductive implant treatment of isolated repairs may be a viable option in the future; however, further study is needed to evaluate the clinical efficacy of bioinductive collagen implants in subscapularis repairs. In the senior author's experience, patients undergoing either IBR or primary repair + bioinductive implant augmentation treatments for partial‐thickness subscapularis tears have done well clinically with early improvement in range of motion.
Several advantages can be attributed to the technique presented in this paper. Although it is unknown if direct biomechanical studies have been performed on bioinductive bovine collagen implants specifically, a study by Warren et al. notes that although the implant does not provide structural integrity, it augments regeneration of host collagen at the repaired tendon and theoretically decreases tension across the repair, 20 with studies showing increased tendon thickness. 22 Additionally, IBR has been shown in previous studies to be a viable option for partial‐thickness superior rotator cuff repairs. 9 Given the complexity of subscapularis repairs, the technique shown here presents an alternative or augmentation to primary repair of the subscapularis, which may be advantageous for arthroscopic surgeons.
Bioinductive implant augmentation is associated with several limitations. An excessive immunologic response may contribute to postoperative pain and stiffness. Yeazell et al. reported a higher incidence of postoperative shoulder stiffness in partial‐thickness rotator cuff tears treated with a bioinductive collagen patch than propensity‐matched controls (25.0% vs 3.1%). 23 For this reason, the senior author suggests an extensive debridement of the rotator interval tissue and ensuring the implant is rolled along the upper border of the subscapularis to prevent excessive biologic response in the rotator interval. In addition, implant cost and availability may limit use in some practice settings. Long‐term implant durability has not been well established, as most studies report follow‐up of only 1 to 2 years. 9 , 10 , 13 , 19 , 24 Further studies are needed to evaluate longer‐term outcomes and to compare bioinductive implant augmentation of a repair versus IBR alone versus repair alone versus observation or debridement for isolated partial‐thickness subscapularis tears. Despite these limitations, the described technique provides a reproducible method for arthroscopic bioinductive implant fixation of partial‐thickness subscapularis tears.
DISCLOSURES
The author (S.A.) declares the following financial interests/personal relationships which may be considered as potential competing interests: S.A. reports leadership or fiduciary role in other board, society, committee, or advocacy group, paid or unpaid, with Arthroscopy Journal: editorial board (unpaid) and Orthopaedic Journal of Sports Medicine: editorial board (unpaid). The other author (A.E.W.) declares that he has no known competing financial interests or personal relationships that could have appeared to influence the work reported in this article.
REFERENCES
- 1. Kim TK, Rauh PB, McFarland EG. Partial tears of the subscapularis tendon found during arthroscopic procedures on the shoulder: A statistical analysis of sixty cases. Am J Sports Med. 2003;31:744‐750. [DOI] [PubMed] [Google Scholar]
- 2. Wang Q, Zhao J, Zhou S, Lv Y, Liu X, Yang H. Quantitative MRI indicators and features for partial subscapularis tendon tears on conventional shoulder MRI. Insights Imaging. 2022;13:168. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3. Sakurai G, Ozaki J, Tomita Y, Kondo T, Tamai S. Incomplete tears of the subscapularis tendon associated with tears of the supraspinatus tendon: Cadaveric and clinical studies. J Shoulder Elbow Surg. 1998;7:510‐515. [DOI] [PubMed] [Google Scholar]
- 4. Ghasemi SA, McCahon JAS, Yoo JC, et al. Subscapularis tear classification implications regarding treatment and outcomes: Consensus decision‐making. JSES Rev Rep Tech. 2023;3:201‐208. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5. Frandsen JJ, Quinlan NJ, Smith KM, Lu CC, Chalmers PN, Tashjian RZ. Symptomatic rotator cuff tear progression: Conservatively treated full‐ and partial‐thickness tears continue to progress. Arthrosc Sports Med Rehabil. 2022;4:e1091‐e1096. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6. Hasler A, Ker A, Passon T, Tondelli T, Gerber C, Wieser K. Nonoperatively managed small‐ to medium‐sized subscapularis tendon tears: MRI evaluation with a minimum of 5 years of follow‐up. JSES Int. 2022;6:84‐90. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 7. Jeong JY, Kim SC, Lee SM, Yoo JC. Prospective randomized clinical trial of arthroscopic repair versus debridement for partial subscapularis tendon tears involving more than half of the first facet. Am J Sports Med. 2023;51:2804‐2814. [DOI] [PubMed] [Google Scholar]
- 8. American Academy of Orthopaedic Surgeons . Management of Rotator Cuff Injuries: Evidence‐Based Clinical Practice Guideline. Rosemont, IL: American Academy of Orthopaedic Surgeons; 2025. https://www.aaos.org/rccpg2025. Accessed January 31, 2026. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9. Bushnell BD, Bishai SK, Krupp RJ, et al. Treatment of partial‐thickness rotator cuff tears with a resorbable bioinductive bovine collagen implant: 1‐year results from a prospective multicenter registry. Orthop J Sports Med. 2021;9:23259671211027850. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10. Camacho Chacón JA, Roda Rojo V, Martin Martinez A, et al. An isolated bioinductive repair vs sutured repair for full‐thickness rotator cuff tears: 2‐year results of a double‐blinded randomized controlled trial. J Shoulder Elbow Surg. 2024;33:1894‐1904. [DOI] [PubMed] [Google Scholar]
- 11. Ruiz‐Ibán MA, García Navlet M, Moros Marco S, et al. Augmentation of a transosseous‐equivalent repair in posterosuperior nonacute rotator cuff tears with a bioinductive collagen implant decreases the retear rate at 1 year: A randomized controlled trial. Arthroscopy. 2024;40:1760‐1773. [DOI] [PubMed] [Google Scholar]
- 12. Dai A, Campbell A, Bloom D, Baron S, Begly J, Meislin R. Collagen‐based bioinductive implant for treatment of partial‐thickness rotator cuff tears. Bull Hosp Jt Dis (2013). 2020;78:195‐201. [PubMed] [Google Scholar]
- 13. Schlegel TF, Abrams JS, Angelo RL, Getelman MH, Ho CP, Bushnell BD. Isolated bioinductive repair of partial‐thickness rotator cuff tears using a resorbable bovine collagen implant: Two‐year radiologic and clinical outcomes from a prospective multicenter study. J Shoulder Elbow Surg. 2021;30:1938‐1948. [DOI] [PubMed] [Google Scholar]
- 14. Alkhateeb J, Langley C, Wong I. Arthroscopic augmentation of subscapularis revision repair using a bioinductive collagen implant. Arthrosc Tech. 2024;13:102993. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 15. Pupa L, Sheth M, Goldenberg N, Shybut T. Tips and tricks for augmenting rotator cuff repair with a bio‐inductive collagen implant. Arthrosc Tech. 2021;10:e2659‐e2665. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 16. Barnes RH, Agan K, Pedroza AD, Cvetanovich GL, Bishop JY. Subscapularis repair augmentation with bioinductive implant during anatomic total shoulder arthroplasty. Arthrosc Tech. 2023;12:e2289‐e2293. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 17. Zheng W, Weng R, Wu X, et al. Clinical efficacy and tendon integrity of patients with subscapularis tear treated with arthroscopic single external row repair. Front Med (Lausanne). 2023;10:1167158. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18. Petriccioli D, Bertone C, Marchi G, Mujahed I. Open repair of isolated traumatic subscapularis tendon tears with a synthetic soft tissue reinforcement. Musculoskelet Surg. 2013;97:63‐68. [DOI] [PubMed] [Google Scholar]
- 19. Castle JP, Kasto JK, Jiang EX, et al. Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient‐reported outcomes and retear rate at 1 year. Shoulder Elbow. 2025;18:266‐276. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 20. Warren JR, Domingo‐Johnson ER, Sorensen AA, Cheng AL, Latz KH, Cil A. Bioinductive patch as an augmentation for rotator cuff repair: A systematic review and meta‐analysis. J Shoulder Elbow Surg. 2024;33:2515‐2529. [DOI] [PubMed] [Google Scholar]
- 21. Yoo J, Lee D. The clinical outcomes of a bioinductive collagen implant in bursal‐sided partial‐thickness rotator cuff tears. Medicina (Kaunas). 2025;61:988. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22. Jenkins R, Mon NO, Ruotolo C. Patch augmentation in the treatment of partial‐thickness rotator cuff tears facilitates tendon healing and improves patient outcomes: A systematic review. Arthroscopy. 2025;41:4826‐4835. [DOI] [PubMed] [Google Scholar]
- 23. Yeazell S, Lutz A, Bohon H, et al. Increased stiffness and reoperation rate in partial rotator cuff repairs treated with a bovine patch: A propensity‐matched trial. J Shoulder Elbow Surg. 2022;31(suppl 6):S131‐S135. [DOI] [PubMed] [Google Scholar]
- 24. Bushnell BD, Connor PM, Harris HW, Ho CP, Trenhaile SW, Abrams JS. Two‐year outcomes with a bioinductive collagen implant used in augmentation of arthroscopic repair of full‐thickness rotator cuff tears: Final results of a prospective multicenter study. J Shoulder Elbow Surg. 2022;31:2532‐2541. [DOI] [PubMed] [Google Scholar]
