Pilot-Scale Demonstration of Foam Fractionation and Hydrothermal Alkaline Treatment for PFAS Removal and Destruction in a Municipal Wastewater Stream

Brian R Pinkard †,‡,*, Erika F Houtz §,*, Ansaf V Karim ∥, Calvin Rhodes †, Randal Marks §, Lottie Franck §, Dennis Raison †, Joshua Arvin †, Somnath Mukherjee †, Juliet Veskova †, Joel Baker ∥, Emese Hadnagy ∥
PMCID: PMC13776608  PMID: 43048504

Abstract

Municipal wastewater treatment plants (WWTPs) are a known focal point for per- and polyfluoroalkyl substance (PFAS) accumulation, transformation, and transport. PFAS from disparate household and industrial sources are conveyed to central WWTPs and often end up in municipal biosolids or in effluent liquids. Treatment of PFAS in a WWTP context is a major technical challenge due to the high flow rates, often low PFAS concentrations, and complexity of the water matrix. Foam fractionation (FF) and hydrothermal alkaline treatment (HALT) are PFAS treatment technologies, capable of concentrating and destroying PFAS, respectively. Foam fractionation leverages the air partitioning propensity of many PFAS to separate these compounds into a concentrated foam, while HALT leverages high temperature and high pH conditions to degrade and defluorinate PFAS. In this study, two continuous flow systems of FF and HALT treated 60,000 L of sludge dewatering pressate as a sequential treatment train at the pilot scale to assess performance metrics in a WWTP context. For the foam fractionation portion, long chain PFAS such as PFOS and PFOA were completely removed, and under the best performing conditions, total measured PFAS were removed by 78%. Following primary fractionation and foamate concentration, a waste product equivalent of one gallon per 490 gallons of water treated was achieved. Subsequently, HALT achieved >99% total measured PFAS destruction and removal in the foamate under the best performing conditions.

Keywords: PFAS, hydrothermal, HALT, foam fractionation, municipal wastewater


graphic file with name ew6c00947_0010.webp


graphic file with name ew6c00947_0008.webp

Introduction

Per- and polyfluoroalkyl substances (PFAS) are a class of persistent organic pollutants (POPs) that have been widely used in consumer products and firefighting foams for decades. Legacy and continued use has led to widespread prevalence of PFAS in common waste collection points, such as landfills − and wastewater treatment plants (WWTPs). Because of the strength of the carbon–fluorine bond, many PFAS are perpetually stable or react to form stable PFAS under environmental conditions. One potential strategy to interrupt the continual cycling of PFAS through the environment, water supply, and food chain, is to apply separation and destruction treatment at a logical PFAS collection point, such as at a landfill, an industrial discharge point, or a WWTP.

PFAS transport and emission from WWTPs is a major technical and societal challenge. PFAS are often found at low concentrations in WWTP influent and effluent, and recent studies have confirmed that several PFAS can transform into perfluoroalkyl acids (PFAAs) during various WWTP unit processes. − Longer-chain PFAS are more prone to sorbing to solids and ending up in biosolids, while shorter-chain PFAS can remain in the liquid WWTP effluent. PFAS can enter the WWTP from industrial discharges, such as landfills, or from disparate residential sources.

Treatment options for PFAS-impacted municipal wastewater are limited due to the high volumetric flow rates and the complexity of the wastewater matrix. Solids and organics can rapidly foul media and membranes, driving prohibitively high treatment cost. Direct destruction of PFAS in municipal wastewater is also impractical due to the scale of existing and emerging PFAS destruction technologies and the operating cost of these approaches. An ideal treatment approach would be (i) largely immune to the complexity of the wastewater matrix, (ii) able to separate and concentrate PFAS into a significantly smaller volume, and (iii) able to destroy concentrated PFAS without shipping waste off-site.

Foam fractionation is a physical separation process wherein air or another gas is bubbled through a water column in order to separate amphiphilic species based on their tendency to partition to an air water interface. Foam fractionation has been used to remove PFAS from PFAS-impacted waters both in situ and ex situ , and is particularly effective at removing PFAS with five or more fluorinated carbons. , De facto foam fractionation also occurs within biological treatment processes that generate foam at municipal wastewater treatment plants, although they are not specifically designed for PFAS removal.

Operationally, impacted water is pumped into a column reactor and mixed in countercurrent flow with air introduced at the bottom. A PFAS rich foam referred to as foamate is formed at the top of the reactor. Foamate can be removed via gravity flow or a mechanical process. Foam fractionation can operate as a batch process or a continuous process, and process parameters such as water and air flow rate, height of the water column, and chemical additives can be used to optimize PFAS removal and improve foamate quality. Ion pairing agents such as cetyltrimethylammonium chloride (CTAC) and cetyltrimethylammonium bromide (CTAB) have been introduced to the water to enhance removal of PFAS with fewer fluorinated carbons with some degree of efficacy, − however there are aquatic toxicity concerns associated with using quaternary amines. Other additives may be introduced to induce or manage the degree of foaming. Foamate can be further concentrated in subsequent foam fractionation columns to minimize the amount of aqueous waste resulting from these systems.

Foam fractionation is notable for its ability to remove PFAS from complex waters where adsorptive media-based solutions such as granular activated carbon (GAC) and ion exchange (IX) resin exhibit poor media lifetime. Specifically, PFAS can be removed from high total organic carbon (TOC) waters without the need for pretreatment, , and from waters with relatively high background total dissolved solids (TDS). As a result of foam fractionation’s robust performance in matrices with these features, multiple municipal landfills have adopted foam fractionation for PFAS removal at scale. Similarly, industrial and domestic wastewaters may be appropriate applications for PFAS removal due to the presence of co-constituents that may compete for adsorptive media sites or otherwise require significant pretreatment for TOC or metals.

Hydrothermal alkaline treatment (HALT) is a thermochemical PFAS destruction process that is notable for its ability to function in complex water and wastewater matrices. − HALT takes place within the liquid, subcritical phase of water, typically at temperatures above 300 °C, pressures above 20 MPa, and pH above 13. Reaction mechanisms involve a combination of thermal decarboxylation and nucleophilic substitution mechanisms, which facilitate parent compound degradation and rapid mineralization of fluorocarbon intermediates. − Perfluorosulfonic acids (PFSAs) require higher temperatures in combination with high concentrations of sodium hydroxide to initiate parent compound degradation, while perfluorocarboxylic acids (PFCAs) will initially degrade via thermal mechanisms alone. Final products of PFAS destruction via HALT include dissolved fluoride, carbonate, and sulfate ions, as confirmed by studies that show good closure of the fluorine mass balance for HALT. ,, Purohit et al. (2026) recently demonstrated that the inherent ionic strength of the HALT process could be leveraged to increase the critical temperature of the reacting solution, enabling operation at temperatures above the critical temperature of pure water (>374.1 °C), which facilitates more rapid reaction kinetics for PFSA degradation. HALT has been demonstrated to destroy PFAS in a wide range of single compound studies − and studies of complex mixtures in real-world matrices. ,,−

HALT has been demonstrated to destroy PFAS in foamate during several lab- and field studies. , HALT is well-suited for processing foamate, as the PFAS degradation mechanism is not impacted by turbidity, and is mostly not impacted by the presence of TOC. Foam fractionation delivers a PFAS-rich liquid with a water chemistry that mostly mimics the source water chemistry, meaning that the destructive technology must be robust to the source water chemistry.

To our knowledge, this is the first study demonstrating the application of foam fractionation on treated PFAS from sludge dewatering pressate and the first study to demonstrate HALT on a municipal wastewater matrix. The intent of the study is to assess the technical feasibility of sequentially applying foam fractionation and HALT to treat PFAS in complex wastewater streams, while simultaneously contextualizing the impact of applying such treatment when compared with the total measured PFAS mass flux through a representative wastewater treatment plant.

Materials and Methods

Wastewater Site and Analysis

The City of Tacoma Central Wastewater Treatment Plant (WWTP) serves a population of approximately 200,000 and several industrial dischargers. It was designed to provide 60 million gallons per day (MGD) secondary biological treatment using a high purity oxygen activated sludge treatment system, a peak wet weather treatment facility (for flows over 60 MGD and up to 150 MGD), and a dual digestion system to produce Class A Biosolids products. Several wastewater streams in the Tacoma Central WWTP were sampled for PFAS analysis by USEPA Method 1633 to identify a waste stream that contained a variety of PFAS at high enough concentrations to be an appropriate candidate for the treatment demonstration. Feasibility of installing the pilot-scale demonstration in the vicinity of the selected wastewater stream was also a consideration during the selection process. Based on these criteria, the sludge dewatering pressate generated by the solids dewatering step, which is a common process at all secondary WWTPs, was selected for the pilot-scale demonstration. The sludge dewatering pressate is the liquid stream produced during the sludge dewatering process, which is recirculated back to the headworks of the WWTP.

The wastewater source was filtered to remove bulk solids prior to introduction to the foam fractionation system. The produced foamate served as the feedstock for the HALT system. Some of the foamate was concentrated through a second fractionation step to achieve a higher PFAS concentration factor and a higher degree of volume reduction. Table S4 shows PFAS concentrations in the sludge dewatering pressate, which contained ∼600 ng/L of PFAS on average in January to February of 2025. The primary constituent in the sludge dewatering pressate is 5:3 FTCA, which is a common constituent in landfill leachate. ,

Treatment Systems

A containerized foam fractionation system (Onterris Treatment Technologies, Inc.; Portland, ME) in a 40-foot weatherized Conex box was provided for the pilot study with two flow-through foam fractionators that can nominally treat between 12 to 56 L of wastewater per minute. The foam fractionators were operated continuously in series, with the foamate from each fractionator combined into a foamate break tank (Figure ). A chemical injection pump was used to inject foam enhancing (i.e., readily biodegradable betaines) and suppressing chemicals into the water ahead of the lead fractionator in select experiments. Recirculation pumps and air injectors were used to introduce air into the fractionators. The system also contained a small-scale continuous flow foamate concentrator for further volume reduction of generated foamate that can operate at approximately 0.06–0.12 L per minute. Additional pretreatment for bulk solids in the form of a roll off box filter and a bag filter skid were added ahead of the foam fractionation equipment to prevent clogging of the wye strainer on the influent pump. This system can typically handle suspended solids without upfront filtration, but the presence of >10% bulk solids required additional pretreatment on this specific waste stream.

1.

1

Onterris foam fractionation block flow diagram.

The HALT system (Aquagga, Inc.; Tacoma, WA) employed for this study is a fully integrated, continuous flow tubular HALT reactor housed within a 2.4 m × 3 m × 3 m (8′ × 10′ × 10′) shipping container. A process flow diagram of the HALT system is shown in Figure . The system is capable of operating at temperatures up to ∼380 °C and pressures up to ∼25 MPa. System throughput was adjusted from 9.5 to 28.5 L per hour (L/h) during the study to vary residence time using a high-pressure diaphragm pump (Milton Roy). Metering pumps were used to dose a selected quantity of 50 wt % NaOH solution into a mixing tank to achieve an overall NaOH molarity between 0.5 and 1.75 M-NaOH. Reaction temperatures were achieved and maintained using electric resistive heaters and Type-K thermocouples; a recuperative heat exchanger was used for reactant preheating prior to entering the reactor vessel as well as cooling of reactor effluent to <100 °C. Pressure was reduced to ambient using a back-pressure regulator (BPR) prior to routing effluent to an IBC tote.

2.

2

Simplified process flow diagram of the HALT system employed in the study.

Reagents

Aqueous NaOH solution (50 wt %, Commercial grade, Cascade Columbia Distribution) was used as the chemical amendment for the HALT feedstock. Sulfuric acid (97%, Commercial grade, Cascade Columbia Distribution) was used to neutralize the HALT effluent prior to final discharge.

Experimental Methods

Approximately 2 weeks of foam fractionation testing was performed. The first week was designed to test foam fractionation performance at different hydraulic retention times (HRTs) and with different chemical additives to evaluate best foam characteristics and optimal PFAS removal. The testing plan included operation with 30- and 60 min HRT, which is a critical design parameter for providing effective treatment and for equipment sizing. The second week was designated for generating sufficient primary and concentrated foamate for treatment with the HALT system. The foam fractionation system ran with manned operations up to 12 h per day. Totalizers tracked the quantity of water treated and the volume of foamate generated was determined by volumetric measurement. Foam concentration occurred over the duration of the pilot under a steady set of operating conditions.

Analytical samples were collected into HDPE bottles out of sample ports for PFAS analysis at the foam fractionator system influent, and in effluent samples out of each fractionator for each test condition. Foamate was periodically sampled and analyzed for PFAS. Concentrator treated water (“recycle”) and concentrated foamate were also sampled and analyzed for PFAS. These results were used in conjunction with measured system flow rates and volumes to determine a PFAS mass balance.

Subsequently, a range of NaOH concentrations, temperatures, and flow rates were tested to characterize the performance of the HALT system, and to produce a range of treatment efficacy data. NaOH concentrations were varied from 0.5 to 1.75 M-NaOH, temperatures were varied from 350 to 370 °C, and system throughputs were varied from 9.5 to 28.5 L/h. The NaOH concentration was established by mixing a defined quantity of 50 wt % NaOH solution with the feedstock, and dosed NaOH concentrations were confirmed by titration of collected effluent samples. System throughput was defined as the flow rate of NaOH-amended feedstock through the system, as verified by gravimetric measurements.

For each test condition, two treated liquid samples were collected in HDPE sample bottles and neutralized with sulfuric acid prior to shipment to commercial laboratories for analysis. For each experimental condition, the reactor was operated for ample time necessary to purge all liquid from the reactor vessel prior to collecting the first sample. Results from duplicate sampling events are shown.

Analytical Methods

PFAS concentrations were determined using LC–MS/MS via isotope dilution using the US EPA Method 1633 analyte list. Samples collected during the initial WWTP sampling campaign were analyzed by the City of Tacoma Environmental Services Laboratory, while the samples collected during the treatment technology demonstration were analyzed at Onterris Laboratories (El Dorado Hills, CA). Influent, foam fractionation treated water samples, and HALT-treated and untreated primary foamate were centrifuged prior to analysis and extracted with Phenomenex Strata X-AW 6 cm3, 200 mg solid phase extraction cartridges. Concentrated foamate samples, including HALT-treated concentrated foamate, were analyzed after serial dilution. Analyte reporting limits depended on the sample type and are indicated in Tables S2 and S3 in the Supporting Information: for untreated and treated sludge dewatering pressate, reporting limits were generally below 2 ng/L (Table S2). For untreated primary and concentrated foamate, reporting limits were above 1000 ng/L (Table S2), and for HALT-treated matrices, reporting limits were below 50 ng/L (Table S3). The Onterris laboratory ran method blanks and laboratory control samples for quality control. All samples and analytes met the Onterris method recovery limits for the isotopically labeled internal standards (25% to 150% for most analytes and 10% to 150% for PFOSA, EtFOSA, MeFOSE, and EtFOSE) with the following exceptions: PFBA was unable to be reported for many samples due to insufficient recovery of its internal standard and the EtFOSE internal standard was over-recovered (150% to 200%) in some HALT-treated samples.

Data Analysis

Mass recovery values during foam fractionation were computed on the basis of the analytical data according to the following equations, where [PFAS] is the concentration of a specific PFAS “i” and V is the total volume of each category recorded

Recoveryi,primaryfractionation=[PFAS]i,primaryfoamate×Vprimaryfoamate[PFAS]i,influent×Vinfluent−[PFAS]i,treatedeffluent×Vtreatedeffluent
Recoveryi,concentrator={[PFAS]i,concentratedfoamate×Vconcentratedfoamate}/{[PFAS]i,primaryfoamate×Vprimaryfoamate−[PFAS]i,concentratoreff×Vconcentratoreff}
Recoveryi,overall=Recoveryi,primaryfractionation×Recoveryi,concentrator

Percent PFAS destruction and removal efficiency was calculated by the following equation

DRE(%)=[PFAS]i,0−[PFAS]i,f[PFAS]i,0×100

where [PFAS] i,0 is analyte concentration before the addition of NaOH and HALT. [PFAS] i,f is analyte concentration following HALT, corrected for dilution by NaOH and sulfuric acid. DRE is strictly a measure of starting and ending concentrations of target PFAS analytes and is not independently indicative of PFAS mineralization or defluorination, which requires a more thorough analysis of the fate of fluorine.

Results and Discussion

Foam Fractionation

The influent PFAS chemistry entering the foam fractionation system (“influent”) is depicted in Figure . 5:3 fluorotelomer carboxylic acid (5:3 FTCA) was the predominant compound detected with an average concentration of 383 ng/L, followed by perfluorohexanoic acid (PFHxA) (71 ng/L), and perfluorobutanesulfonic acid (PFBS) (51 ng/L). 5:3 FTCA comprised approximately 60% of the total measured PFAS mass (629 ng/L, average), so overall PFAS removal depended heavily on the performance of 5:3 FTCA. The prevalence of 5:3 FTCA was consistent with the preceding anaerobic sludge digestion process, as 5:3 FTCA is a commonly measured product of anaerobically degraded 6:2 fluorotelomer material. − Compounds with USEPA drinking water maximum contaminant levels (MCLs) were detected in the following average concentrations: PFOS (44 ng/L), PFOA (15 ng/L), perfluorononanoic acid (PFNA) (2 ng/L), perfluorohexanesulfonic acid (PFHxS) (6 ng/L) and hexafluoropropylene oxide-dimer acid (HFPO–DA) (ND; <0.8 ng/L). One influent sample indicated a temporal spike in PFOS at 170 ng/L compared to approximately 15 ng/L for all the other sampling events. One raw influent sample, collected prior to the solids filtration step, was similar in relative and absolute PFAS concentrations to the filtered samples (Figure ), indicating the filtration step did not substantially remove PFAS. Complete tabular PFAS results for foam fractionation influent, treated samples, foamate, and concentrated foamate are located in Table S2a–c.

3.

3

Influent PFAS chemistry. The left panel identifies individual sample concentrations and the right panel identifies the average concentration of PFAS in raw influent and influent to the foam fractionation system.

The different foam fractionation conditions tested are summarized in Table . Test conditions were designed to test a variety of realistic operating conditions. The addition of boost agents was considered in concert with other parameters, primarily air flow rate. Using a foam suppressant typically enables higher air flow rates. Final treated water concentrations of PFAS are depicted in Figure . Under all trial conditions tested, all PFAS with specific MCLs that were present in the influent (i.e., PFOS, PFOA, PFHxS, PFNA) were removed below the method detection limits in the treated effluent (Figure ). Removal of 5:3 FTCA, PFHxA, PFBS, and perfluoropentanoic acid (PFPeA) was enhanced at slower flow rates/longer HRTs (Figure ), as was observed in Vo et al. Best removal (78% total measured PFAS removal) was observed under the Trial 1 operating conditions (Figures and ), in which no additives were used to suppress or enhance foaming and low air flow rates were utilized. This suggests that best performance for non-MCL compounds will require a longer HRT and larger equipment, however higher air flow and chemical additives that add to operating costs can be minimized. Non-MCL compounds demonstrate progressive removal through the two stages of fractionation, especially 5:3 FTCA (Figure ).

1. Description of Foam Fractionation Trial Conditions .

Trial condition flow rate,L/m hydraulic retention time, min boost agent (lead fractionator/lag fractionator) air flow rate, lead fractionator (scfm) air flow rate, lag fractionator (scfm)
Trial 1 15 60 none <5 <5
Trial 2 30 30 none <5 <5
Trial 3 15 60 foam suppressant/none 5–10 5–10
Trial 4 30 30 foam suppressant/none <5 5–10
Trial 5 30 30 foam suppressant/FF boost 5 to 10 5–10
a

Scfm = standard cubic feet per minute. L/m = liters per minute.

4.

4

PFAS concentration in treated water by varying trial conditions. Note: colorless bars represent nondetect values.

5.

5

PFAS concentrations under best performing trial condition #1. Note: colorless bars represent nondetect values.

If treatment goals only include MCL PFAS, the conditions utilized in Trial 2 (Figure )shorter HRT/higher flow rate, low air flow rate, and no chemical additiveswill suffice. PFOS, PFHxS, and PFNA were each removed below the PFOS/PFOA 4 ng/L MCL in the effluent of the lead fractionator, including on the day when PFOS was measured at 170 ng/L in the influent (Trial 4, Figure ). PFOA was removed to below its MCL on three out of the five trials in the lead fractionator, suggesting it benefits from both stages of fractionation to ensure removal below MCLs.

Limited data on PFAS removal in foam fractionation of wastewater exists, and most has been collected in bench experiments rather than pilot or full-scale efforts. , Compared with other pilot foam fractionation studies in leachate, another matrix with significant organic matter and dissolved solids, removal efficiencies of PFAS were similar: , negligible removal of PFAS with four perfluoroalkyl carbons, improved removal of PFAS with five perfluoroalkyl carbons as retention time increased, and near complete removal of PFAS with six or more perfluoroalkyl carbons. As discussed in the introduction, cationic surfactants can be used to improve shorter chain PFAS removal in foam fractionation systems, − but their toxicity profile has limited their adoption due to concerns of incomplete removal in the treated water.

Primary foamate generated from the two stages of fractionation conducted in Trials 1 to 5 were collected, combined, and fed into the concentrator to further concentrate the foamate. The primary PFAS present and removed from the influent, including 5:3 FTCA, PFOS, and PFOA were detectable in most of these foamate samples (Table S2a–c). Due to the complexity of these matrices, many compounds were not reportable above their limit of detection.

Primary foam fractionation achieved a concentration factor of 64, and the overall process concentration factor achieved by volume was 487x when employing further foamate concentration. Using the PFAS concentrations in primary foamate, treated concentrator effluent, and concentrated foamate, and the overall average values for influent and treated effluent (Figure S4), mass recoveries were computed for both PFOS and 5:3 FTCA, the only two compounds that were consistently measured in all three media. Two samples each of primary and concentrated foamate were available to use for mass balance calculations. Both 5:3 FTCA and PFOS were fully recovered (126% and 92%, respectively) in the primary foamate, and 5:3 FTCA and PFOS were recovered at 44% and 46% in concentrated foamate, respectively. Overall, through primary foam fractionation and foamate concentration, PFOS was recovered at 40% and 5:3 FTCA was recovered at 58%. Because PFOS was relatively variable in the influent (Figure ), this may have contributed to the lower overall recovery of PFOS than 5:3 FTCA. Additionally, the low sample count, coupled with the matrix complexity of the foamate and concentrated foamate, introduce nontrivial uncertainty into the mass balance determination.

Hydrothermal Alkaline Treatment

Figure shows PFAS destruction and removal results for the treatment of primary foamate at operating conditions from 350 to 370 °C, with NaOH concentrations of 0.5 and 1.75 M-NaOH. At 0.5 M-NaOH, the system throughput was varied from 9.5 to 28.5 L/h, which resulted in increasingly higher residual PFAS concentrations. Increasing the NaOH concentration to 1.75 M-NaOH and operating at a higher temperature resulted in PFAS destruction and removal to total concentrations of ∼200 ng/L. The “system blank” was also measured to contain ∼200 ng/L of PFAS, reflective of PFAS carryover from other projects using the same HALT system.

6.

6

Total measured PFAS concentrations before and after HALT treatment at various operating conditions for the primary foamate.

Increasing the residence time (by decreasing flow rate), increasing the operating temperature, and increasing the NaOH concentration all increased the extent of total measured PFAS destruction and removal. Looking more closely at speciation data, Table shows that this trend is primarily driven by the DRE of PFSAs. PFCAs and FTSs are degraded to similar levels at all operating conditions, with >99% DREs for all tests. Sulfonamides and FTCAs (the primary class of PFAS in the foamate) are reduced to levels below detection limits for all tested conditions. However, the PFSAs show DREs that range from 17 to 98.4% depending on the aggressiveness of the operating condition.

2. PFAS Concentrations in the Primary Foamate by Subclass before and after HALT Processing .

      370 °C, 0.5 M-NaOH, 9.6 L/h
350 °C, 0.5 M-NaOH, 10.8 L/h
350 °C, 0.5 M-NaOH, 19.8 L/h
350 °C, 0.5 M-NaOH, 28.3 L/h
370 °C, 1.75 M-NaOH, 12.1 L/h
PFAS subclass primary foamate system blank PF 1.1 PF 1.2 PF 2.1 PF 2.2 PF 3.1 PF 3.2 PF 4.1 PF 4.2 PF 5.1 PF 5.2
PFCA 11,284 5 47 45 45 54 35 28 20 24 ND 37
PFSA 13,643 53 3984 3569 6063 6139 6634 5927 11,685 10,947 241 188
sulfonamide 634 5 ND ND ND ND ND ND ND ND ND ND
PFECA ND ND ND ND ND ND ND ND ND ND ND ND
PFESA ND ND ND ND ND ND ND ND ND ND ND ND
FTOH 73 ND ND ND ND ND ND ND ND ND ND ND
FTCA 40,865 ND ND ND ND ND ND ND ND ND ND ND
FTS 11,920 140 112 55 49 28 68 38 22 28 20 18
total measured PFAS 78,419 203 4143 3670 6157 6220 6737 5992 11,726 10,999 261 244
DRE % - - 94.7% 95.3% 92.1% 92.1% 91.4% 92.4% 85.0% 86.0% 99.7% 99.7%
a

PFAS concentrations are in ng/L. Non-detects are indicated by ND. Reporting limits of individual species are indicated in Table S3.

This trend is consistent with the known HALT PFSA destruction mechanism reported by Hao et al. PFSA destruction is highly sensitive to reaction temperature and NaOH concentration. Within the context of PFAS destruction in a municipal wastewater setting, there is a clear trade-off between aggressiveness of the HALT operating condition, which correlates with the operating cost associated with HALT, and the extent of PFAS mass destroyed. When the HALT effluent can be recycled to the foam fractionation system, it may be possible to keep the residual PFSAs within the overall treatment system, allowing for milder HALT conditions and reduced operating costs. In scenarios where HALT effluent is directly polished for discharge, it may be desirable to operate at more aggressive conditions to target a higher PFSA DRE.

Complicating this discussion is the reality that different WWTPs will have different PFAS speciation profiles, and PFAS speciation will vary throughout the WWTP. 5:3 FTCA is a common compound in landfill leachate, due to the anaerobic digestion of 6:2 fluorotelomer compounds present in carpets and furniture. However, WWTPs located close to AFFF-impacted areas may see a higher prevalence of legacy PFAS such as PFOS and PFHxS. Additionally, the stream treated in this work is downstream of the sludge dewatering process; many long-chain and sulfonated PFAS will remain sorbed to the biosolids, which may impact the distribution of PFAS subspecies in the foamate received by HALT.

Figure shows the results of PFAS treatment via HALT for a concentrated foamate sample, where the foamate was reprocessed through the foam fractionation system to generate higher concentrations of PFAS in a smaller volume of liquid. This provides practical benefits of reducing the volumetric treatment need for HALT; however, this requires additional foam fractionation infrastructure. Treatment at 370 °C and 1.75 M-NaOH shows a >99.9% total measured PFAS DRE, with significantly more PFAS mass treated in this test due to the higher starting concentrations. Despite this, nondetect levels of all PFAS were not reached, meaning further polishing or recirculation of the HALT effluent would be required for discharge.

7.

7

Total measured PFAS before and after HALT for concentrated foamate.

Measurements of PFAS disappearance are not enough, in isolation, to confirm effective mineralization of PFAS to inorganic fluoride. A more robust sampling and analysis campaign would be needed, potentially involving measurements of fluoride release, total organofluorine (TOF), total oxidizable precursor (TOP) assay, non-target analysis, and other techniques. Due to the relatively low concentrations of PFAS in the primary foamate, many of these techniques would be difficult to apply for this study, especially due to the complexity of the matrix. While the HALT mechanism has been robustly evaluated previously ,, and fluorine mass balance has been evaluated in other studies, , the results presented here are not sufficient to independently establish complete mineralization of the PFAS measured here. We encourage the reader to interpret these results within the context of these prior studies.

Beyond PFAS destruction and removal performance, implementation of HALT must also consider known practical challenges around hard mineral scale buildup and reactor corrosion. Calcium and magnesium can precipitate in the high pH, high temperature HALT environment, leading to plugging of system components if not addressed proactively. Additionally, the harsh operating conditions can lead to corrosion of the high temperature system components over a prolonged service lifetime. While neither of these practical challenges were evaluated in the course of this study, Smith et al., assessed and discussed these challenges, finding that calcium and magnesium concentrations dropped significantly after HALT processing. Preconditioning of the HALT influent can be a successful strategy to reduce hard mineral concentrations in the HALT influent, as can periodic cleaning of the system with an acid. Smith et al. also reported no discernible increase of corrosion byproducts in the HALT effluent at operating conditions similar to those employed in this study. Incorporation of properly selected wetted materials to mitigate the caustic corrosion mechanism can be a successful strategy for mitigating component corrosion in the HALT environment.

PFAS Mass Tracking

Based on the results of the limited sampling campaign at the Tacoma Central WWTP in combination with data available in the literature, the pilot demonstration is contextualized from the basis of overall PFAS mass removal and destruction. Two scenarios are considered: (i) treatment at the scale of the pilot demonstration itself, and (ii) treatment of the entire sludge dewatering pressate stream. Overall PFAS mass removal and destruction are considered relative to the total mass flux of PFAS through a representative WWTP.

A detailed PFAS mass balance on the Central WWTP was not conducted. Due to seasonal variability in flows, coupled with significant hydraulic retention times for various unit processes within the plant, it is not possible to accurately characterize the entire fate of PFAS within the WWTP from the limited sampling campaign. Additionally, it is well-known that PFAS are biotransformed within WWTPs, meaning influent PFAS data often underestimate the total measured PFAS mass flow through a WWTP. , Numbers are presented for rough order of magnitude (ROM) context only, based on the data available from the study and from the literature.

From plant flow rate and PFAS data collected in May 2024, an assessment of PFAS removal in the overall plant flow can be estimated. A plant influent flow rate of 656 L per second (L/s) was reported and a flow rate for the sludge dewatering pressate of 9.5 L/s was reported. The plant flow rates and PFAS concentrations are similar (within roughly one order of magnitude) to those reported in the literature from other WWTPs. , Based on the performance data collected in this pilot and June flow rate estimates, approximately 0.46 g of total measured PFAS could hypothetically be removed per day via treating the sludge dewatering pressate vs an influent daily flow of approximately 57 g per day, as shown in Tables and S4. Factoring in the foam fractionation removal efficiency of ∼78% observed in the pilot, this number drops to ∼0.36 g/day of PFAS that can be removed and destroyed. Based on these estimates, less than 1% of the total measured PFAS flow through the plant could be removed by targeting this location. Due to the influent flow rates, the use of foam fractionation and HALT to treat the entire flow would likely be cost prohibitive due to capital cost considerations, while the treatment of the sludge dewatering pressate stream may be plausible from a capital cost and capacity perspective.

3. Measured PFAS Mass Flux at Various Locations in the Tacoma Central WWTP, Compared with Total Measured PFAS Mass Removed and Destroyed Using the Foam Fractionation and HALT Treatment Approach.

sampling location total measured PFAS concentration (ng/L) flow rate (m3/day) total measured PFAS mass flux (g/day) required FF capacity (L/min) required HALT capacity (L/min) total measured PFAS mass removed & destroyed (g/day)
influent ∼1003 ∼56,700 ∼56.8 ∼39,400 ∼81 ∼44.3
effluent ∼79 ∼56,700 ∼4.48 ∼39,400 ∼81 ∼3.49
sludge dewatering pressate ∼618 ∼821 ∼0.46 ∼570 ∼1.2 ∼0.36
a

From single sampling event in May, 2024.

b

Average concentration from sampling data in January and February, 2025.

c

Assuming ∼78% FF removal efficiency and ∼99% HALT PFAS destruction efficiency.

We present this technical performance data in the context of an ongoing discussion within the community of practice concerning the most logical locations and strategies to implement PFAS treatment technologies. Much regulatory attention has been paid to PFAS treatment in a drinking water context, due to the obvious direct correlation to human exposure and human health. Beyond this, much dialogue within the industry has considered where and how to implement PFAS treatment, recognizing that the presence of PFAS at contaminated sites, in landfills, and in WWTPs is widespread, diffuse, and challenging to treat. Ling et al. recently studied the projected costs of removing PFAS from selected remediation sites, large drinking water zones, wastewater sludges, and landfill leachates. The authors report that removing and treating 3 to 50 tons per year of PFAS from the environment may cost €100 B per year if short-chain PFAS are addressed, which would represent ∼2% of the PFAS mass emitted to the environment each year from manufacturing activities. PFAS removal and destruction from wastewater effluent is estimated at €1 M to €7 M per kg-PFAS. The primary conclusion of Ling et al.’s study is that treating PFAS at point sources, particularly in industrial discharges, as source control is likely to be significantly more cost-effective than treating low concentrations of PFAS in the high flow volumes of a WWTP.

An alternative option is to implement this treatment train as part of WWTP pretreatment programs to target incoming wastewater streams that contain higher levels of PFAS, thus potentially achieving overall higher PFAS mass removals (e.g., treating PFAS from an incoming landfill leachate wastewater stream). Particulate amendments at strategic locations within the treatment plant, such as the activated sludge process, can partition PFAS into specific outgoing streams, lowering PFAS in the treated effluent without adding significant treatment equipment to the footprint. Within a WWTP context, we recommend that future work focus on the total measured PFAS mass that can be removed and destroyed by treating PFAS in a WWTP or industrial discharge setting, as treating PFAS in the entire flow of a municipal WWTP may be cost prohibitive.

Conclusions

This study demonstrated that the removal and destruction of PFAS from municipal wastewater is technically feasible through a combination of foam fractionation and HALT.

At a flow rate of 570 L/min of the sludge dewatering pressate waste stream, pilot data indicates an estimated foamate production rate of 1,7000 L/day. The 487x concentration factor resulted in a much more manageable flow rate of PFAS-impacted water to be treated with HALT destruction technology. Additional optimization of the concentrator and addition of a hyper concentrator could result in further volume reduction of the foamate stream. An additional pretreatment waste stream, the filter solids removed ahead of the foam fractionation system, was not addressed in this study. However, it can be relatively easily managed by returning the filter solids to the head of the sludge dewatering process or elsewhere within the plant.

The foam fractionation operating conditions that achieved the best overall PFAS removal did not rely on high air flow or chemical additives, which is favorable for O&M costs for full-scale applications in similar settings. Similarly, HALT achieved high DREs even when operated under relatively mild NaOH concentrations of 1.75 M-NaOH.

The overall mass flux through a WWTP relative to the mass that can be removed and destroyed for a given stream within a WWTP must be considered to determine the overall effectiveness and value in integrating the described technologies. While the current study targeted the treatment of the sludge dewatering pressate water due to ease of implementation at the study site and the presence of highest PFAS concentrations among the tested wastewater streams, applying these technologies at the point of discharge into the wastewater collection system as part of pretreatment programs could be a viable alternative resulting in higher overall mass removals. For full-scale integration into a treatment plant site, additional considerations should be given for site constraints, power needs, waste stream neutralization, and other site-specific needs (e.g., treatment capacity upgrades for growth).

Supplementary Material

ew6c00947_si_001.pdf (614.3KB, pdf)

Acknowledgments

We would like to thank the Washington State Department of Ecology for funding this work (Ecology Contract number WQNEPSW-2023-UWTaco-00008). This research has been funded wholly or in part by the United States Environmental Protection Agency (EPA) under assistance agreement PC-01J89501 to the Washington State Department of Ecology (via the EPA Puget Sound Geographic Funds through the Stormwater Strategic Initiative). The contents of this article do not necessarily reflect the views and policies of the Environmental Protection Agency or the Washington State Department of Ecology, nor does mention of trade names or commercial products constitute endorsement or recommendation for use. We would also like to thank members of the City of Tacoma Environmental Services Laboratory for their partnership and support on this project, including Teresa Peterson, Monica Herbert, Tiffany Ryan, and Stuart Magoon. Aquagga would like to thank Mike Czerski, Ariella Halevi, Cody Thomsen, Augusto Millevolte, Conrad Austin, and Quinn Huelsbeck for assistance with the planning, preparation, and completion of the reported work. Onterris thanks J Alan Esteves, Dan Casey, and Paul Rodriguez for their assistance in bench work, project planning and execution.

The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsestwater.6c00947.

  • Full analytical laboratory reports, including QA/QC documentation and standard recoveries, are available from the corresponding authors upon reasonable request (PDF)

⊥.

B.R.P. and E.F.H. Equally contributing first author. The manuscript was written by contributions of all authors. All authors have given approval to the final version of the manuscript.

The authors declare the following competing financial interest(s): Authors BP, CR, DR, JA, and SM are employees and stock or equity holders of Aquagga, Inc., which has a financial interest in the herein described hydrothermal alkaline treatment (HALT) technology. Authors EH, RM, and LF are employees of Onterris, which sells foam fractionation equipment and services. All other authors declare no competing financial interests.

References

  1. Lin D., Méndez M., Paterson K., Wong A., Yee D., Sutton R., Houtz E., Cousins M., Fono L.. Residential Wastewater as a Major Source of Per- and Polyfluoroalkyl Substances to Municipal Wastewater. ACS EST Water. 2024;4(11):4847–4857. doi: 10.1021/acsestwater.4c00507. [DOI] [Google Scholar]
  2. Capozzi S. L., Leang A. L., Rodenburg L. A., Chandramouli B., Delistraty D. A., Carter C. H.. PFAS in Municipal Landfill Leachate: Occurrence, Transformation, and Sources. Chemosphere. 2023;334:138924. doi: 10.1016/j.chemosphere.2023.138924. [DOI] [PubMed] [Google Scholar]
  3. Lang J. R., Allred B. M., Field J. A., Levis J. W., Barlaz M. A.. National Estimate of Per- and Polyfluoroalkyl Substance (PFAS) Release to U.S. Municipal Landfill Leachate. Environ. Sci. Technol. 2017;51(4):2197–2205. doi: 10.1021/acs.est.6b05005. [DOI] [PubMed] [Google Scholar]
  4. Coffin E. S., Reeves D. M., Cassidy D. P.. PFAS in Municipal Solid Waste Landfills: Sources, Leachate Composition, Chemical Transformations, and Future Challenges. Curr. Opin. Environ. Sci. Health. 2023;31:100418. doi: 10.1016/j.coesh.2022.100418. [DOI] [Google Scholar]
  5. Liu J., Charbonnet J. A.. A Critical Review of PFAS Analysis, Occurrence, and Fate in Wastewater Treatment Plants. Environ. Sci. Technol. 2025;59(48):25492–25517. doi: 10.1021/acs.est.5c09949. [DOI] [PubMed] [Google Scholar]
  6. Schultz M. M., Higgins C. P., Huset C. A., Luthy R. G., Barofsky D. F., Field J. A.. Fluorochemical Mass Flows in a Municipal Wastewater Treatment Facility. Environ. Sci. Technol. 2006;40(23):7350–7357. doi: 10.1021/es061025m. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Houtz E., Wang M., Park J.-S.. Identification and Fate of Aqueous Film Forming Foam Derived Per- and Polyfluoroalkyl Substances in a Wastewater Treatment Plant. Environ. Sci. Technol. 2018;52(22):13212–13221. doi: 10.1021/acs.est.8b04028. [DOI] [PubMed] [Google Scholar]
  8. Lemlich R., Lavi E.. Foam Fractionation with Reflux. Science. 1961;134(3473):191. doi: 10.1126/science.134.3473.191. [DOI] [PubMed] [Google Scholar]
  9. Burns D. J., Stevenson P., Murphy P. J. C.. PFAS Removal from Groundwaters Using Surface-Active Foam Fractionation. Remediat. J. 2021;31(4):19–33. doi: 10.1002/rem.21694. [DOI] [Google Scholar]
  10. Smith S. J., Wiberg K., McCleaf P., Ahrens L.. Pilot-Scale Continuous Foam Fractionation for the Removal of Per- and Polyfluoroalkyl Substances (PFAS) from Landfill Leachate. ACS EST Water. 2022;2(5):841–851. doi: 10.1021/acsestwater.2c00032. [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Burns D. J., Hinrichsen H. M., Stevenson P., Murphy P. J. C.. Commercial-Scale Remediation of per- and Polyfluoroalkyl Substances from a Landfill Leachate Catchment Using Surface-Active Foam Fractionation (SAFF®) Remediat. J. 2022;32(3):139–150. doi: 10.1002/rem.21720. [DOI] [Google Scholar]
  12. Smith S. J., Lewis J., Wiberg K., Wall E., Ahrens L.. Foam Fractionation for Removal of Per- and Polyfluoroalkyl Substances: Towards Closing the Mass Balance. Sci. Total Environ. 2023;871:162050. doi: 10.1016/j.scitotenv.2023.162050. [DOI] [PubMed] [Google Scholar]
  13. Buckley T., Karanam K., Han H., Vo H. N. P., Shukla P., Firouzi M., Rudolph V.. Effect of Different Co-Foaming Agents on PFAS Removal from the Environment by Foam Fractionation. Water Res. 2023;230:119532. doi: 10.1016/j.watres.2022.119532. [DOI] [PubMed] [Google Scholar]
  14. Lee C.-S., Venkatesan A. K.. Cationic Surfactant-Assisted Foam Fractionation Enhances the Removal of Short-Chain Perfluoroalkyl Substances from Impacted Water. Chemosphere. 2024;362:142614. doi: 10.1016/j.chemosphere.2024.142614. [DOI] [PubMed] [Google Scholar]
  15. Stevenson P., Karakashev S. I.. Commercial-Scale Removal of Short-Chain PFAS in a Batch-Wise Adsorptive Bubble Separation Process by Dosing with Cationic Co-Surfactant. Remediat. J. 2024;34(1):e21767. doi: 10.1002/rem.21767. [DOI] [Google Scholar]
  16. Klevan C., Van Allen O., Mukai K., Gomes A., Xia S., Caines S., Woodcock M. J., Pennell K. D.. Removal of Long- and Short-Chain PFAS from Groundwater by Foam Fractionation. Environ. Sci. Water Res. Technol. 2025;11(10):2295–2307. doi: 10.1039/D5EW00440C. [DOI] [Google Scholar]
  17. Arnold W. A., Blum A., Branyan J., Bruton T. A., Carignan C. C., Cortopassi G., Datta S., DeWitt J., Doherty A.-C., Halden R. U., Harari H., Hartmann E. M., Hrubec T. C., Iyer S., Kwiatkowski C. F., LaPier J., Li D., Li L., Muñiz Ortiz J. G., Salamova A., Schettler T., Seguin R. P., Soehl A., Sutton R., Xu L., Zheng G.. Quaternary Ammonium Compounds: A Chemical Class of Emerging Concern. Environ. Sci. Technol. 2023;57(20):7645–7665. doi: 10.1021/acs.est.2c08244. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Robey N. M., da Silva B. F., Annable M. D., Townsend T. G., Bowden J. A.. Concentrating Per- and Polyfluoroalkyl Substances (PFAS) in Municipal Solid Waste Landfill Leachate Using Foam Separation. Environ. Sci. Technol. 2020;54(19):12550–12559. doi: 10.1021/acs.est.0c01266. [DOI] [PubMed] [Google Scholar]
  19. Sabba F., Kassar C., Kimbell L., Zeng T., Hunter G.. Optimizing Foam Fractionation for PFAS Removal from Landfill Leachate: Treatment Performance and Operational Insights. Sci. Total Environ. 2026;1010:181050. doi: 10.1016/j.scitotenv.2025.181050. [DOI] [PubMed] [Google Scholar]
  20. Buckley T., Vuong T., Karanam K., Vo P. H. N., Shukla P., Firouzi M., Rudolph V.. Using Foam Fractionation to Estimate PFAS Air-Water Interface Adsorption Behaviour at Ng/L and Μg/L Concentrations. Water Res. 2023;239:120028. doi: 10.1016/j.watres.2023.120028. [DOI] [PubMed] [Google Scholar]
  21. Pinkard B., Smith S. M., Vorarath P., Smrz T., Schmick S., Dressel L., Bryan C., Czerski M., de Marne A., Halevi A., Thomsen C., Woodruff C.. Degradation and Defluorination of Ultra Short-, Short-, and Long-Chain PFASs in High Total Dissolved Solids Solutions by Hydrothermal Alkaline Treatment–Closing the Fluorine Mass Balance. ACS EST Eng. 2024;4(11):2810–2818. doi: 10.1021/acsestengg.4c00378. [DOI] [Google Scholar]
  22. Pinkard B. R., Austin C., Purohit A. L., Li J., Novosselov I. V.. Destruction of PFAS in AFFF-Impacted Fire Training Pit Water, with a Continuous Hydrothermal Alkaline Treatment Reactor. Chemosphere. 2023;314:137681. doi: 10.1016/j.chemosphere.2022.137681. [DOI] [PubMed] [Google Scholar]
  23. Smith S. M., Pinkard B. R., Zweifel T., Dressel L., Vorarath P., Junes C., Gibeault J., Malinsky J., Hackbarth T., Halevi A., Thomsen C., Rhodes C., Mukherjee S., Ellis A.. Demonstration of Hydrothermal Alkaline Treatment for PFAS Destruction in Industrial Wastewater: Assessment of Degradation, Defluorination, Fluorine Mass Balance, and Potential for Volatile Organofluorine Formation. Chem. Eng. J. 2026;535:175150. doi: 10.1016/j.cej.2026.175150. [DOI] [Google Scholar]
  24. Austin C., Purohit A. L., Thomsen C., Pinkard B. R., Strathmann T. J., Novosselov I. V.. Hydrothermal Destruction and Defluorination of Trifluoroacetic Acid (TFA) Environ. Sci. Technol. 2024;58(18):8076–8085. doi: 10.1021/acs.est.3c09404. [DOI] [PubMed] [Google Scholar]
  25. Hao S., Payton B., Soker O., Ellis A., Brooks S., Reardon P., Vyas S., Popovs I., Novosselov I., Higgins C., Strathmann T.. Complete Mineralization of Trifluoromethanesulfonate via Subcritical Hydrothermal Reaction: Reaction Mechanism and Transformation Pathways. Environ. Sci. Technol. 2026;60(26):18878–18889. doi: 10.1021/acs.est.6c00018. [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Wu B., Hao S., Choi Y., Higgins C. P., Deeb R., Strathmann T. J.. Rapid Destruction and Defluorination of Perfluorooctanesulfonate by Alkaline Hydrothermal Reaction. Environ. Sci. Technol. Lett. 2019;6(10):630–636. doi: 10.1021/acs.estlett.9b00506. [DOI] [Google Scholar]
  27. Pinkard, B. ; Novosselov, I. ; Austin, C. ; Purohit, A. . Method for Increasing the Kinetic Rate of a Reaction, and Related Components and Systems. WO 2025059616 A2, 2025.
  28. Hao S., Choi Y.-J., Wu B., Higgins C. P., Deeb R., Strathmann T. J.. Hydrothermal Alkaline Treatment for Destruction of Per- and Polyfluoroalkyl Substances in Aqueous Film-Forming Foam. Environ. Sci. Technol. 2021;55(5):3283–3295. doi: 10.1021/acs.est.0c06906. [DOI] [PubMed] [Google Scholar]
  29. Hao S., Choi Y. J., Deeb R. A., Strathmann T. J., Higgins C. P.. Application of Hydrothermal Alkaline Treatment for Destruction of Per- and Polyfluoroalkyl Substances in Contaminated Groundwater and Soil. Environ. Sci. Technol. 2022;56(10):6647–6657. doi: 10.1021/acs.est.2c00654. [DOI] [PubMed] [Google Scholar]
  30. Hao S., Reardon P. N., Choi Y. J., Zhang C., Sanchez J. M., Higgins C. P., Strathmann T. J.. Hydrothermal Alkaline Treatment (HALT) of Foam Fractionation Concentrate Derived from PFAS-Contaminated Groundwater. Environ. Sci. Technol. 2023;57(44):17154–17165. doi: 10.1021/acs.est.3c05140. [DOI] [PubMed] [Google Scholar]
  31. Pinkard B. R.. Aqueous Film-Forming Foam Treatment under Alkaline Hydrothermal Conditions. J. Environ. Eng. 2022;148(2):05021007. doi: 10.1061/(ASCE)EE.1943-7870.0001974. [DOI] [Google Scholar]
  32. Padhye L. P.. et al. The PFAS Roadmap – Navigating a Path Together to Improved Management. Sustain. Sci. Technol. 2025;3:012501. doi: 10.1088/2977-3504/ae286f. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Wang Q., Zhang T., Liu X., Liu S., Wang X., Wang X.. The Fate of 6:2 Fluorotelomer Alcohol in Anaerobic Landfill Leachate: Implication for Fugitive Emission from Waste Landfills. Environ. Pollut. 2025;376:126375. doi: 10.1016/j.envpol.2025.126375. [DOI] [PubMed] [Google Scholar]
  34. Zhang S., Szostek B., McCausland P. K., Wolstenholme B. W., Lu X., Wang N., Buck R. C.. 6:2 and 8:2 Fluorotelomer Alcohol Anaerobic Biotransformation in Digester Sludge from a WWTP under Methanogenic Conditions. Environ. Sci. Technol. 2013;47(9):4227–4235. doi: 10.1021/es4000824. [DOI] [PubMed] [Google Scholar]
  35. Yaqoob S., Wu C., Li C., Antunes J. M. D., Li M.. Anaerobic Biotransformation and Biodefluorination of 6:2 Fluorotelomer Carboxylic Acid by Biosolids under the Nitrate-Reducing Condition. ACS EST Water. 2025;5(5):2412–2420. doi: 10.1021/acsestwater.5c00009. [DOI] [Google Scholar]
  36. Vo P. H. N., Nguyen T. T. P., Nguyen H. T. M., Baulch J., Dong S., Nguyen C. V., Thai P. K., Nguyen A. V.. PFAS Removal from Landfill Leachate by Ozone Foam Fractionation: System Optimization and Adsorption Quantification. Water Res. 2024;253:121300. doi: 10.1016/j.watres.2024.121300. [DOI] [PubMed] [Google Scholar]
  37. We A. C. E., Chen C. X., Stickland A. D., Clarke B. O., Freguia S.. Influence of Microbial Communities on Foam Fractionation of Wastewater for PFAS Removal. Water Res. 2026;291:125144. doi: 10.1016/j.watres.2025.125144. [DOI] [PubMed] [Google Scholar]
  38. Malovanyy A., Forsén E., Lihammar R.. Removal of Per- and Polyfluoroalkyl Substances (PFAS) from Municipal Wastewater by Foam Fractionation. Water Res. 2025;268:122660. doi: 10.1016/j.watres.2024.122660. [DOI] [PubMed] [Google Scholar]
  39. Houtz E. F., Sutton R., Park J.-S., Sedlak M.. Poly- and Perfluoroalkyl Substances in Wastewater: Significance of Unknown Precursors, Manufacturing Shifts, and Likely AFFF Impacts. Water Res. 2016;95:142–149. doi: 10.1016/j.watres.2016.02.055. [DOI] [PubMed] [Google Scholar]
  40. Ebrahimi F., Lewis A. J., Sales C. M., Suri R., McKenzie E. R.. Linking PFAS Partitioning Behavior in Sewage Solids to the Solid Characteristics, Solution Chemistry, and Treatment Processes. Chemosphere. 2021;271:129530. doi: 10.1016/j.chemosphere.2020.129530. [DOI] [PubMed] [Google Scholar]
  41. Schaefer C. E., Hooper J. L., Strom L. E., Abusallout I., Dickenson E. R. V., Thompson K. A., Mohan G. R., Drennan D., Wu K., Guelfo J. L.. Occurrence of Quantifiable and Semi-Quantifiable Poly- and Perfluoroalkyl Substances in United States Wastewater Treatment Plants. Water Res. 2023;233:119724. doi: 10.1016/j.watres.2023.119724. [DOI] [PubMed] [Google Scholar]
  42. US Environmental Protection Agency . National Primary Drinking Water Regulations. https://www.epa.gov/ground-water-and-drinking-water/national-primary-drinking-water-regulations (accessed 2026–09–01).
  43. Ling A., Aubert R., Bersi E., Horel S., Arp H. P.. PFAS Remediation across Europe: Costs and Limited Impacts. Environ. Sci. Process. Impacts. 2026;28(7):2092–2109. doi: 10.1039/D5EM00870K. [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

ew6c00947_si_001.pdf (614.3KB, pdf)

Articles from ACS Es&t Water are provided here courtesy of American Chemical Society

RESOURCES