Abstract
Vehicle-based measurement systems occupy an important niche in the multiscale methane measurement landscape between component-level technologies and aerial-based methods. Performance evaluations are often limited to one dimension (e.g., quantification), while methodological opacity limits interpretation and intercomparisons between technologies. Here, we develop a vehicle-based measurement unit employing repeated site-perimeter transects and a processing framework featuring a novel weighted-likelihood algorithm for automated source attribution. Using controlled release experiments at two dedicated testing facilities, we characterize system performance across three dimensionsdetection, attribution, and quantification. The system achieved a 94.5% true-positive detection rate with no false positives and a 90% detection limit as low as 0.078 kg/h with five repeat transects. Attribution accuracy was high at the source-group level, reaching 99.7% in single-source releases and 86% in multisource scenarios. Quantification was unbiased for low-to-moderate complexity releases (2 source groups; slope = 0.99, R 2 = 0.81) but overestimated under highly complex conditions (5 source groups; slope = 1.45, R 2 = 0.91). These results provide a transparent performance benchmark, demonstrating that these systems are well-suited to survey the large populations of low-to-moderate-complexity sites (e.g., single wells and batteries), as a screening layer in LDAR applications, and to quantify the low end of emission distributions in inventories, reducing reliance on generic emission factors.
Keywords: methane detection, vehicle-based measurement, oil and gas, emission quantification, attribution, controlled release experiment


1. Introduction
Methane (CH4), the primary component of natural gas, is a potent greenhouse gas with a 100-year global warming potential 27–30 times that of CO2. The oil and gas (O&G) sector accounts for an estimated 44% of anthropogenic CH4 emissions in Canada and 20% globally. , As a result, it has been identified as a key sector for CH4 emission reduction. Jurisdictions, including Canada, the United States, and the European Union, have implemented regulations targeting CH4 emissions from this sector. − These regulations mandate leak detection and repair (LDAR) programs, which involve regular site-level emission screening to identify and repair fugitive emission sources.
The need to characterize and reduce CH4 emissions has driven the rapid development of CH4 measurement technologies for two primary applications: targeted monitoring and mitigation (e.g., LDAR) and emission inventory development. Regulatory programs have accelerated this trend by providing pathways for the use of alternative CH4 measurement technologies beyond traditional optical gas imaging (OGI) surveys in LDAR programs. , Existing technologies include spaceborne and airborne methods (satellites, aircraft, and drones) and ground-based approaches (vehicle-mounted, handheld, and stationary monitors). Fundamental trade-offs exist among these technologies in terms of spatial and temporal coverage, attribution granularity, cost, ease of deployment, detection sensitivity, and quantification accuracy. However, because of their different advantages and capabilities, there is a growing consensus that multiscale measurements are essential for characterizing the overall CH4 emission landscape. −
Vehicle-based measurement systems occupy an important niche in this multiscale measurement framework. Typically consisting of a vehicle equipped with a CH4 analyzer, GPS, and meteorological sensors, these systems offer spatial coverage and detection sensitivity that fall between component-level OGI surveys and larger-scale aerial measurements. − Here, we focus on fully mobile approaches that detect and quantify emissions during downwind transects rather than methods that rely on extended measurements at fixed locations downwind (e.g., OTM-33A). Such vehicle-based systems have been used extensively to characterize CH4 emissions from oil and gas production sites, − urban environments and natural gas distribution networks, − biogas facilities, and landfills. Although similar instrumentation may be used across these applications, measurement and analysis approaches can differ significantly due to differences in source location information, source and environmental complexity, and measurement constraints. In downstream natural gas distribution, for example, source locations are generally unknown, vehicle routes are limited to existing road networks, and the surrounding urban environment is highly complex. This contrasts with upstream O&G applications, where potential source locations are typically known and driving routes around these sources are more flexible, which can facilitate detection, source attribution, and emission quantification. Emission rates in upstream O&G applications are most commonly estimated using atmospheric concentration measurements coupled with atmospheric dispersion modeling in an inversion framework, although lidar and tracer-based techniques have also been used.
To date, research on vehicle-based systems in upstream O&G applications has largely focused on emission quantification, with comparatively less attention given to detection sensitivity and source localization. Localization approaches have varied widely across studies, including manual attribution, ,, automated nearest-upwind-source algorithms whose reliability has not yet been evaluated, , triangulation across multiple site visits under varying wind conditions, and optimization-based methods that exhibited localization errors of ∼30–40 m within a 40–50 m domain. , Several studies have examined the detection performance of vehicle-based methods in downstream settings; ,, however, these findings are not directly transferable to upstream applications for the reasons outlined above. Peer-reviewed controlled release evaluations of localization and detection performance for vehicle-based systems in upstream O&G applications remain scarce. Ravikumar et al. reported promising results across several systems, while Ilonze et al. observed poor localization and were unable to establish a 90% probability of detection threshold for the single vehicle-based system tested. Field-based estimates suggest detection limits below 0.5 kg/h based on theoretical minimum detectable CH4 enhancements and dispersion modeling, , while controlled release experiments report limits ranging from 0.096 to >10 kg/h. This variability is difficult to interpret because it reflects differences in instrumentation, methodology, and operating conditions, and many approaches rely on proprietary methods that are not fully disclosed. As a result, reproducibility is limited and interstudy comparability is constrained, ultimately presenting a barrier to the adoption of this technology in LDAR and inventory development applications.
In this study, we aim to improve understanding of the role that vehicle-based measurement systems can play within a multiscale measurement framework through a detailed methods description and comprehensive evaluation of system performance. We develop a vehicle-based measurement system comprising a vehicle-mounted measurement unit, a measurement protocol of five consecutive site-perimeter transects, and a processing framework for automated CH4 detection, source attribution, and quantification in the upstream O&G sector. Using data collected from controlled-release experiments at two dedicated testing facilities that simulate realistic single- and multisource upstream O&G emission scenarios, we present the first comprehensive and transparent performance characterization of a vehicle-based measurement system across three dimensionsdetection, attribution, and quantificationand compare its capabilities with those of other commonly used CH4 measurement technologies. In doing so, we aim to establish a performance benchmark that informs the broader scientific and regulatory communities about the capabilities, limitations, and potential role of vehicle-based systems in LDAR programs and CH4 inventory development.
2. Materials and Methods
2.1. Vehicle-Based Measurement Unit
We collected measurements using a compact and portable vehicle-mounted unit developed by FluxLab at St. Francis Xavier University (Figure ). Mounted to any vehicle using standard roof racks, the unit consists of a tunable diode laser spectrometer (TDLAS; Axetris LGD Compact-A CH4) with an empirical precision (1σ) of ∼0.2 ppm, a GPS (GlobalSat), and a 2-D ultrasonic anemometer (Gill WindUltra). Ambient air is drawn from above the vehicle into an enclosure containing the TDLAS sensor by an air pump operating at a flow rate of 0.6 LPM, where CH4 concentrations are measured. Measurements of CH4 concentration, wind speed, wind direction, and vehicle location (latitude and longitude) are recorded at 2 Hz using a microcontroller (ESP32). An internal modem enables wireless data transmission and real-time data viewing on any browser-enabled device. The unit is powered by a 12 V lithium battery, providing up to 8 h of continuous operation, and has a total weight of <10 kg (22 pounds). Inlet height depends on the height of the vehicle upon which it is mountedin this study, it was approximately 3 m. These data form the measurement inputs to the processing framework.
1.

The rooftop-mounted vehicle-based measurement unit.
2.2. Defining Source, Site, and Source Group
In addition to these measurements, information on the locations and heights of potential emission sources is required for data processing. Throughout this text, the term source refers to an individual piece of equipment on an O&G site (e.g., a wellhead or storage tank). A site refers to a collection of equipment within a geographic boundary that typically functions together for a common operational purpose (e.g., a compressor station or single-well battery). A source group refers to a cluster of sources positioned close together such that individual emitters would be difficult to reliably distinguish using downwind transect measurements. For this study, sources were grouped manually into source groups, with group diameters ranging from 8 to 20 m (Figure ). In field applications, there can be significant variation in the number and arrangement of sources and source groups on a site. Examples of source groups on O&G production sites are provided in the Supporting Information (SI; Figure S1), illustrating the different degrees of spatial complexity that may be encountered in field settings.
2.

Map of the CMC (left) and METEC (right) controlled release facilities used in these experiments, showing individual source locations (blue circles), source groups (green outline), and full site (orange outline).
2.3. Processing Framework
Using the measurement and source data described above, our processing framework consists of four sequential steps: data preprocessing, CH4 peak detection, source attribution, and quantification, each of which is described in detail below.
2.3.1. Preprocessing
First, the raw measurement time series are prepared for subsequent analysis. This includes synchronizing measurements across instruments with different sampling frequencies onto a common timeline, interpolating missing values, and correcting raw measured wind speed and direction for vehicle motion. The CH4 time series is shifted backward in time by 6 s to account for the sensor response time and transit time through the tubing between the inlet and the gas analyzer. We determined the time shift by introducing a short duration (∼1 s) CH4 pulse at the instrument inlet and measuring the delay between the pulse and the maximum CH4 concentration recorded by the analyzer. We repeated this procedure 10 times and used the mean time shift across tests.
Hourly observations of cloud cover, cloud ceiling height, and 10 m wind speed from the nearest airport are used to estimate discrete atmospheric stability classes. In this approach, the stability class is determined from the wind speed and estimates of a net radiation index. This index depends on cloud cover, ceiling height, and insolation, which are estimated from solar altitude (a function of date, time, and location).
2.3.2. Peak Detection
We analyze the CH4 time series to identify elevated CH4 values (“peaks”). First, we calculate a dynamic CH4 baseline as an estimate of atmospheric background CH4 concentrations using an iterative mean suppression method inspired by Liland, assuming that there are only CH4 sources and no sinks, such that the lowest measured concentrations reflect background levels. We prepare the CH4 signal by trimming leading and trailing NA values, thresholding the data to reduce the influence of large amplitude CH4 peaks, mirroring the signal at both ends to avoid edge effects, and smoothing the resulting series. We then subsample the CH4 data by selecting the minimum value within fixed intervals to simplify the shape of the smoothed signal and increase speed.
We estimate the baseline iteratively on the prepared CH4 time series by moving a window of exponentially decreasing size along the signal, calculating the mean value in each window, and replacing values that exceed the mean with the mean. Each window is applied first to the right (time-increasing direction) and then to the left to prevent directional bias.
We subtract the CH4 baseline time series from the measured CH4 time series to produce a time series of excess CH4 (eCH4), which was used for peak detection. Peaks in the eCH4 time series are identified using a spike detection algorithm described by Daniels et al., which iterates through each observation and evaluates conditions that define the start, end, and validity of CH4 peaks. The algorithm requires three input parameters that can be adjusted depending on the application and the gas analyzer characteristics: the going-up threshold, return threshold, and peak amplitude threshold. These parameters were set to 0.05 ppm, 50%, and 0.5 ppm, respectively. Input parameter selection is discussed in more detail in the SI (Section S1). To minimize directional bias, we applied the algorithm in both the forward (time-increasing) and backward (time-decreasing) directions. We merged peaks detected during both passes and assigned sequential ID numbers from left to right. An example of the baseline calculation and spike detection algorithm outputs is shown in Figure S2.
2.3.3. Source Attribution
Once the peaks in the eCH4 time series have been identified, we attribute each peak to a known source group using a weighted-likelihood algorithm that considers measured wind characteristics and the relative locations of candidate sources and the peak location. The peak location is defined as the coordinates at which the peak maximum eCH4 value was recorded. We define a metric called the total attribution weight (w total), ranging from 0 to 1, that characterizes the relative likelihood of each candidate source being associated with the detected plume. We assume that a candidate source located close to and directly upwind of the peak location is most likely to contribute to the detected plume, with w total decreasing with increasing crosswind distance and source–peak distance. The limitations of this assumption are discussed in SI Section S2.
For a given CH4 peak, w total (eq ) is calculated for each candidate source within a search radius d max of the peak location as the product of a distance weight (w d) and azimuth weight (w a).
| 1 |
The distance weight depends on the distance from the source to the location of the measured peak. The x-axis is defined by the mean measured wind direction over a 2 min period. w d decreases exponentially from 1 at an upwind distance (x) of 0 m to a minimum weight value w min at a maximum distance d max according to eq :
| 2 |
where y is the crosswind distance.
To account for uncertainty in peak location, we also define an exponentially decreasing weight for negative upwind distances (i.e., downwind distances) to a much smaller downwind distance d back (eq ).
| 3 |
The azimuth weight (eq ) depends on the azimuth of the source with the wind direction relative to the peak location and is represented by a scaled Gaussian function that covers a triangular area.
| 4 |
where σ is the standard deviation of the Gaussian function. Here, σ is taken to be the standard deviation of the measured wind direction over a 2 min period in radians. Figure S3 shows the distance, azimuth, and total weights as a function of upwind and crosswind distance.
Candidate sources are ranked according to w total for each CH4 peak. Peaks for which no candidate source exceeds a minimum attribution weight threshold of 0.01 are classified as unattributed and are not carried forward in the analysis. Otherwise, the peak is assigned to the source group containing the candidate source with the highest w total. Attribution is performed independently for each peak, resulting in a set of CH4 peak–source group pairs that are used in the quantification step described below. All sources within the attributed source group are considered potential origins of the detected methane plume during quantification.
2.3.4. Quantification
An emission rate is estimated for each attributed CH4 peak through comparison of measured eCH4 values to those modeled with a Gaussian plume dispersion model. This model is frequently employed to describe time-averaged atmospheric dispersion of nonreactive pollutants and assumes the dispersion of these pollutants follows a normal distribution in the vertical (z) and crosswind (y) directions. It assumes steady-state, uniform wind conditions and treats the source as a continuous point emitter. The equation can be obtained as a stationary solution to the atmospheric diffusion equation. For methane, total reflection of the plume off the ground is assumed, resulting in the following eq (eq ) for modeled eCH4 concentration at a point (x,y,z), where x is the along-wind distance from the source, y is the crosswind distance, and z is the height above ground, for an emitting source at height h:
| 5 |
where Q is the emission rate of the source at point (0, 0, h); u is the mean horizontal wind speed, and σ y and σ z are the horizontal and vertical dispersion coefficients, respectively, which depend on atmospheric stability and the downwind distance from the source (x). We calculate these dispersion coefficients according to parametrizations for rural environments. For each attributed CH4 peak, we determine wind direction using the geographic coordinates of the source and the peak, assuming the peak maximum occurs on the plume centerline directly downwind of the source. This is consistent with prior studies, which have demonstrated that this assumption produces more accurate emission rate estimates than using measured wind direction . ,,, However, it is a conservative assumption that could result in underestimation of emission rates if the true plume centerline was not transected. Following the same studies, the modeled eCH4 concentrations are calculated with eq for each point in the measured CH4 peak using a reference emission rate (Q ref) of 1 g/s. The modeled and measured eCH4 values are integrated (or summed) over the crosswind distance y, and the emission rate is estimated using eq .
| 6 |
To quantify emissions at the source-group level, we calculate an emission rate for each source within the group using its individual location and height following the method outlined above. The mean of the rates calculated for all sources in the group is reported. When a source group is tagged as emitting across multiple transects, we calculate the mean emission rate across transects, which has been shown to converge toward the true release rate, while the median tends to result in more pronounced underestimation. , If multiple source groups on a site are tagged as emitting during a measurement event, the mean group-level rates are summed to obtain the site-level emission rate.
2.4. Controlled-Release Experiments
Data from two controlled-release experiments were used to evaluate the detection, attribution, and quantification performance of the vehicle-based CH4 measurement system. The measurements were conducted by Eotrac Incorporated (Eotrac) and were provided for detailed analysis.
2.4.1. Measurement Protocol
Eotrac’s standard work practice targets five driven loops or “transects” around the periphery of a site, hereafter referred to as a “measurement event”, at driving speeds between 4 and 20 km/h. During the controlled release experiments, 81% of measurement events contained 5 usable transects and 93% contained between 4 and 6, with minor variation due to release timing and occasional instrument or data-quality issues. In both experiments, Eotrac was informed of potential source locations; however, specific release locations and flow rates were kept blind during testing. Data was therefore collected in a way that is representative of upstream O&G field deployments, in which potential source locations on site are known, but the precise locations and rates are not.
2.4.2. Carbon Management Canada
Controlled release testing was conducted at the Carbon Management Canada (CMC) test facility at their Newell County field research station near Brooks, Alberta, over 5 days from March 24 to 28, 2025. With five possible source locations divided into two source groups (Figure , left), the site configuration during these tests simulated real-world emission sources such as tanks, separator buildings, and well pad equipment representative of a production site of low-to-moderate complexity. Release heights ranged from 0 to 5 m, and release rates ranged from 0.025 to 3.564 kg CH4/h, with 74% of releases concentrated below 0.25 kg/h, as shown in Figure (left). In total, 97 measurement events were performed across 5 days, with events dominated by single-source releases (88%), followed by multisource releases (8%), and no-source releases (4%).
3.

Distribution of site-level release rates across measurement events for the CMC (left) and METEC (right) controlled release experiments.
2.4.3. Methane Emissions Technology Evaluation Center
Controlled release testing was conducted at the Methane Emissions Technology Evaluation Center (METEC) in Fort Collins, Colorado, over 3 days from April 28 to 30, 2025. Releases followed the ADED 2.0 blind controlled testing protocol, which aims to simulate realistic multisource emission scenarios representative of normal baseline operational emissions, periodic maintenance, and equipment failures. The portion of the site used for this experiment contained 24 potential source locations divided into five source groups (Figure , right), including tanks, separators, and well pads, ranging in height from 1 to 5 m. Total site-level release rates ranged from 0.343 to 16.443 kg CH4/h, with a cluster around 7 kg/h (Figure , right). In total, 62 measurement events were performed, two of which were no-release, with the rest performed during multisource releases with a mean of 4.5 emitting source groups per measurement event. With the large number of source groups and multisource emission scenarios, this is representative of a highly complex O&G production site. Table outlines additional details about each experiment, including source-sensor measurement distances, vehicle speed, wind speed, and atmospheric stability class.
1. Summary of Measurement Events and Experimental Conditions for the CMC and METEC Controlled-Release Experiments.
| CMC | METEC | |
|---|---|---|
| measurement events | 97 | 62 |
| transects | 488 | 304 |
| source heights (m) | 0–5 | 1–5 |
| source-sensor distance (m) | 17 (5.3–22.8) | 34.8 (17.7–45.6) |
| wind speed (m s–1) | 3.7 (2.9–4.4) | 4.0 (3.2–4.9) |
| vehicle speed (km h–1) | 8.1 (6.9–9.3) | 10.0 (9.3–10.7) |
| stability class (%) | B: 6; C: 28; D: 66 | B: 7; C: 28; D: 65 |
Range of source heights tested.
Values are reported as mean (interquartile range).
Percentages represent the proportion of transects assigned to each stability class.
2.5. Analysis Methods
While measurements during the controlled-release experiments were conducted in a blinded fashion, the analysis presented here was performed after release rates and locations were unblinded and provided by Eotrac to facilitate evaluation of method performance. The processing framework used here differs slightly from that used by Eotrac, which may contribute to differences between our results and those reported in their controlled release white paper. Measurement events with fewer than four usable transects (n = 7) were excluded from the analysis. The performance characterization presented here is specific to the hardware, processing framework, and measurement protocols applied in this study.
2.5.1. Detection Classifications
A positive detection is reported if an eCH4 peak is attributed to on-site equipment on at least two transects during a given measurement event. We evaluated the overall detection performance at the measurement-event level using all events with at least four usable transects. We classified these events (n = 152) into four detection categories: true positive (TP), false positive (FP), true negative (TN), and false negative (FN) detections.
For a measurement event with a nonzero release rate, detection outcomes were classified as either TP, when emissions are present and a detection is reported, or FN, when emissions are present but no detection is reported. The fractions of each outcome were calculated using eqs and :
| 7 |
| 8 |
For a measurement event with a release rate of zero, outcomes were classified as either FP, when a detection is reported despite no emissions being present, or TN, when no detection is reported, calculated using eqs and :
| 9 |
| 10 |
These metrics represent the average detection performance across the range of conditions tested during the controlled release experiments, including release rates, source and site configurations, and meteorological conditions (Table ).
2.5.2. Event-Level Probability of Detection
Probability of detection (POD) represents the likelihood of detecting an emitting source under a specific set of environmental and measurement conditions. POD is typically reported for a single measurement observation, which here corresponds to one transect (one complete loop around the site). However, real-world survey protocols for this technology involve repeat transects per site visit rather than a single pass; in this study, there were five transects per measurement event on average. Between transects, small fluctuations in environmental conditions (e.g., wind speed or direction) or in the vehicle path can create different detection opportunities. The event-level POD (PODevent), therefore, represents the detection performance under realistic deployment conditions.
Preliminary analysis using a multivariable logistic regression indicated that the site-level emission rate was the strongest predictor of detection success, with detection odds increasing sharply with increasing emission rate (SI Section S3). We focus subsequent analysis on the relationship between PODevent and the emission rate and examine how PODevent changes with increasing transects per measurement event.
We modeled the relationship between PODevent and emission rate using an exponential function (eq ), which ensures a probability of zero at an emission rate (x) of zero, and can represent the skewed nature of the response variable.
| 11 |
The curve fitting parameters (a and b) were estimated using a binary generalized linear model (GLM) with a complementary log–log link function, using reported detection (yes/no) as the response variable and the log of the emission rate as the predictor.
We used a two-level bootstrap procedure to investigate how detection performance changes as the number of transects per measurement event is increased from n = 2 to 5. For each value of n, we ran 1000 iterations in which measurement events were resampled with replacement with stratification by release rate to preserve the number of events per rate. Within each resampled event, we randomly subsampled n transects recorded during that event (without replacement) and classified the event as a positive detection if at least two of the selected transects registered detections.
For each bootstrap iteration, we fit the complementary log–log GLM to the event-level detection outcomes and emission rates. Detection limits corresponding to 90% POD with 95% CIs were calculated by inverting the fitted models and taking the median and the 2.5 and 97.5th percentiles across the bootstrap distributions for each value of n.
To contextualize the detection performance of this method relative to that of other technologies, we compiled lower detection limits from controlled release studies published since 2019. Studies were identified through Google Scholar searches targeting controlled release tests of OGI, handheld, stationary, vehicle, drone, aircraft, and satellite technologies. Studies were selected based on relevance and the availability of quantitative detection limit data. Detection limit ranges for each technology and corresponding references are provided in Table S4.
2.5.3. Attribution
We evaluated attribution performance for single- and multisource release scenarios using the CMC and METEC controlled release data, respectively. For CMC single-source releases, there was one true source and five potential source locations, divided into two source groups (Figure , left). We assessed attribution accuracy as the percentage of CH4 peaks correctly attributed at the source, group, and site levels. For METEC multisource releases, up to five source groups were emitting simultaneously, and we assessed attribution accuracy as the percentage of emitting and nonemitting source groups correctly categorized across all measurement events.
2.5.4. Quantification
We evaluated the quantification performance of the measurement system by comparing estimated site-level emission rates to the true release rates. We excluded certain CH4 peaks from the quantification analysis when they fell outside the “operational envelope” of the quantification method, including peaks detected during stationary periods or at very low driving speeds (<3 km/h), and peaks for which the ratio of horizontal source distance to the relative source-inlet vertical offset was less than 8:1. This reflects the physical limitations of measuring emissions from a tall source, and the need for adequate distance for the plume to disperse downward toward the inlet. Additionally, a source group had to be tagged on at least two transects to be included in quantification, increasing confidence in both attribution and emission rate estimates. After applying these criteria, 8 CMC measurement events with reported detections were excluded from the quantification analysis. We plotted true versus estimated site-level emission rates for each measurement event and performed a linear regression through the origin. Systematic bias in the method was evaluated via the slope of the best-fit line, where a slope near 1 indicates minimal bias, while R 2 captures the overall strength of the relationship between true and estimated rates. The fraction of emission estimates within a factor of 2 (−50 to +100% error) and a factor of 3 (−67 to +200% error) of the true release rate was also calculated.
As an example of regulatory LDAR applications in Canada, we defined emission rate bins by order of magnitude (0–1, 1–10, 10–100 kg/h) to reflect the different repair timelines prescribed for leaks of different magnitudes under Canada’s amended oil and gas CH4 regulations. We evaluated the ability of this method to correctly triage site-level emission rates based on the proportion of events correctly classified into their respective magnitude bins.
2.5.5. Site-Level Emission Rate Uncertainty
For each measurement event, we estimated site-level emission rate uncertainty using a bootstrapping approach. For each iteration (n = 1000), we resampled emission rate estimates with replacement within each source group and calculated the mean emission rate across resampled estimates. We summed source group means to produce a site-level total emission rate. This process was repeated 1000 times per measurement event to generate empirical distributions of site-level total emission rates, from which bootstrap-derived 95% CIs, defined as the 2.5 and 97.5th percentiles, were calculated. Only source groups with two or more emission rate estimates were included. Relative uncertainty for each measurement event was calculated using eq :
| 12 |
Mean relative uncertainty was then calculated across all measurement events.
3. Results and Discussion
3.1. Event-Level Detection Rate and Probability of Detection
Across the two controlled release experiments, the vehicle-based measurement system had a true-positive detection rate of 94.5% (Figure ). Out of the eight measurement events in which emissions were present but not detected (false negative), all were at release rates of <0.1 kg/h, with 5/8 at the lowest emission rate tested (0.025 kg/h). The system exhibited a false positive rate of 0%, meaning that emissions were only detected when they were truly present.
4.

Confusion matrix of detection performance at the measurement-event level across both controlled release experiments.
The detection performance improves substantially as the number of transects per event increases, as shown by event-level POD curves as a function of emission rate for two to five transects (Figure , left). For two measurement transects, we estimated a 90% PODevent and 95% CI of 0.623 (0.400, 0.951) kg/h. This drops by more than a factor of 2 to 0.265 (0.152, 0.454) kg/h for three transects and continues to drop with additional transects, reaching 0.078 (0.039, 0.105) kg/h for five transects (Figure , right).
5.

(Left) Event-level probability of detection curves as a function of release rate for n = 2 to 5 measurement transects, with the dashed horizontal line indicating the 90% POD threshold. (Right) Detection limit (kg CH4/h) corresponding to the 90% POD threshold as a function of the number of measurement transects. Shaded regions represent the 95% CI in both panels.
The detection sensitivities reported here represent performance across the conditions encountered during the controlled release experiments (Table ) for this measurement system. As the CH4 sensor used in this system has a relatively low measurement precision of ∼0.2 ppm (1σ), detection sensitivity is expected to increase for more sensitive CH4 sensors with which smaller perturbations in the CH4 time series could be detected. Furthermore, as discussed in Section S3, other parameters such as source-to-sensor distance and atmospheric stability are also expected to impact detection performance. While the release conditions are representative of typical on-site measurements of an O&G site, further investigation is needed to characterize the impact of other parameters on detection performance across a wider range of measurement conditions.
A key finding of this work is that event-level detection performance can be improved by adjusting the number of measurement transects, rather than depending solely on refinements to the measurement unit itself, e.g., increasing sensor precision. This illustrates a trade-off between sensor quality and measurement effort that can be leveraged to meet target detection thresholds. High detection sensitivities are achievable with a low-cost, lower-precision sensor rather than the research-grade analyzers (e.g., cavity ring-down or off-axis integrated cavity output spectroscopy instruments) typically employed in vehicle-based measurement studies, provided that sufficient transects are performed. While detection performance is expected to plateau at higher transect counts, no plateau was observed over the range of two to five transects evaluated here. Additional transects beyond five may improve detection performance under similar conditions, but the extent of further improvement was not evaluated in this study. On the basis of the POD analysis, we recommend a minimum of five transects per measurement event when detection of low-emission sources is a priority. These results align with those of Luetschwager et al. in the downstream sector, who found that increasing sampling effort improves POD and recommended driving each roadway 5–8 times to detect most sources.
Compared with other CH4 detection technologies, including OGI and advanced handheld detection methods, this vehicle-based approach demonstrates high detection performance with a 90% POD threshold well below the detection requirements for alternative technologies outlined in LDAR regulations. ,, Figure illustrates the range of lower detection limits (90% POD thresholds when available) of CH4 detection technologies from recent controlled release literature. − ,,− Specific detection limit ranges and references for each technology are listed in Table S4. Ilonze et al. reported 90% POD limits ranging from 0.06 to 1.32 kg/h for handheld OGI and from 0.04 to 1.15 kg/h for advanced handheld solutions, while Zimmerle et al. reported 90% POD for OGI of 0.12 and 1.59 kg/h for surveyors with high and low experience, respectively.
6.

Comparison of CH4 lower detection limit ranges across measurement technologies. Gray bars represent ranges reported in the published literature and the red bar represents the vehicle-based method tested in this study. Detection limits represent 90% POD thresholds unless otherwise noted in Table S4. The shaded blue region represents the range of detection sensitivity requirements for alternative technologies used in LDAR programs, where more sensitive detection limits can result in reduced screening frequency requirements. The upper quantification limit for quantitative OGI (QOGI) technology is also shown (gray triangle).
Compared to Bridger Photonics’ Gas Mapping LiDAR (GML), for which 90% POD thresholds of 0.75 and 2.3 kg/h have been reported for 3 m/s wind speeds, , this vehicle-based approach with five measurement transects is roughly an order of magnitude more sensitive. In contrast to OGI, the vehicle-based method is not expected to exhibit dependence on operator skill, provided simple driving instructions can be followed. There are, however, other potential limitations to applying this method, including site layouts that do not permit complete driven loops around the site. While detection performance was high across the range of emission heights (0–5 m) tested here, previous studies have highlighted that truck-based detection performance may degrade for tall sources (e.g., tanks) compared to other equipment types.
3.2. Attribution Performance in Single- and Multisource Releases
In single-source release experiments, attribution accuracy was 100% at the site level, 99.7% at the group level, and 49% at the source level. These results indicate very strong performance in identifying the emitting source group while highlighting challenges in pinpointing the precise within-group source. This limitation is expected for downwind mobile measurements, where uncertainty in the peak location, combined with wind variability and plume turbulence, makes it difficult to resolve exact leak locations. This is consistent with findings from Ilonze et al., who reported lower localization performance at the source (equipment) level for mobile solutions (vehicle and drone) relative to handheld technologies. For this reason, we opted to attribute peaks at the group level rather than the source level.
For the multisource controlled release experiments conducted at METEC, attribution performance was assessed at the group level by determining whether emitting and nonemitting groups were correctly identified. Across all measurement events, 86% (n = 238) of the 277 emitting groups were correctly tagged as emitting, and 15% (n = 2) of the 13 nonemitting groups were incorrectly tagged as emitting. While attribution performance decreases slightly under complex multisource release scenarios relative to single-source releases, the results demonstrate strong performance in identifying emitting groups and a low false-positive rate.
Overall, these results indicate that the measurement system is well-suited for identifying emission locations at the subfacility scale, even in complex emission scenarios. This level of attribution granularity is sufficient for inventory applications in which emission rates are typically reported at the facility level. Furthermore, given the rapid site-level screening time (<10 min), this approach could be a valuable complement to more intensive LDAR survey techniques, enabling rapid triage and prioritization of component-level follow-up inspections.
3.3. Site-Level Quantification Performance
Quantification performance varied significantly with release complexity. For low-to-moderate complexity release scenarios (1–2 emitting source groups), quantification performance was unbiased with a regression slope of 0.994 and R 2 = 0.81 (Figure , left). For high-complexity release scenarios (mean 4.5 simultaneous emitting source groups), estimated site-level emission rates were systematically higher than true release rates, with a regression slope of 1.45 and R 2 = 0.91 (Figure , right). This 45% overestimation is consistent with challenges in attributing emissions in an environment with multiple colocated source groups emitting simultaneously. In these scenarios, plume overlap between adjacent sources can increase the likelihood that emissions from one source are partially attributed to a neighbouring source, inflating total site-level emissions. The high R 2 value suggests that the method reliably captures relative differences in site-level emission rates, despite these challenges with overestimation.
7.

Estimated vs true site-level emission rates during the CMC experiments (left), representative of a low-to-moderate-complexity site, and the METEC experiments (right), representative of a high-complexity site. The linear regression line through the origin is shown in blue, and the 1:1 line is shown as a dashed line.
Overall, we find that 78% of emission estimates are within a factor of 2 of the true release rate (−50 to +100% error), and 95% are within a factor of 3 (−67 to +200% error). Quantification error tends to be larger for small release magnitudes (see Figure S5), particularly below 1 kg/h. Across all individual measurement events, quantification error ranges from −50.4 to 347.5% (2.5 to 97.5th percentile); however, when emission rates below 1 kg/h are excluded, this range narrows to −39.7 to 170.2%. Figure S6 shows uncertainty for each site-level emission estimate represented by error bars, derived via bootstrapping of individual emission estimates. The mean relative uncertainty across all measurement events was 40%, comparable to uncertainties reported for other CH4 monitoring solutions. ,
These results are within a reasonable range of other vehicle-based quantification approaches, which have reported factor-of-two performance ranging from roughly 18–92% depending on the study and technology. ,− More broadly, the factor-of-two performance of 78% demonstrated here exceeds that of several other commonly used CH4 quantification technologies. Factor-of-two performance ranging from 25 to 46% has been reported for QOGI , between 36 and 40% for drone-based methods, between 50 and 78% for continuous monitors, and 33% for hi-flow samplers. Our error range (2.5 to 97.5th percentile) for emission rates above 1 kg/h (−39.7 to 170.2%) is comparable to that of Bridger Gas Mapping LiDAR (−58.5 to 129.4%, calculated from Bell et al. SI), generally considered among the most accurate quantification technologies available but requiring greater logistical effort and cost.
To our knowledge, this is the first study evaluating the quantification performance of this type of vehicle-based measurement system in release scenarios of varying complexity, as previous studies using this approach have focused exclusively on single-source release scenarios. ,,, Our results highlight that complex multisource scenarios introduce quantification challenges that are not present with a single source, but the method reliably captures relative differences in site-level emission magnitudes as reflected in the high R2 of 0.91. Future work should focus on refining methods for robust separation of overlapping plumes, to avoid double-counting emissions from colocated sources.
3.4. LDAR and Inventory Applications
We now examine how the system's performance translates to the two primary applications motivating this work: LDAR programs and emission inventory development. Categorization accuracy into Canada’s regulatory LDAR repair threshold bins was high in low-to-moderate complexity release scenarios, at 94% (51/54) correct classification in the 0–1 kg/h bin and 83% (15/18) in the 1–10 kg/h bin (Table ). In high complexity scenarios, classification accuracy was 100% in the 0–1 kg/h (1/1) and 10–100 kg/h (12/12) bins but dropped to 49% (22/45) in the 1–10 kg/h bin, largely due to the overestimation bias observed in high-complexity release scenarios. With a mean true release rate of 6.7 kg/h in the 1–10 kg/h bin, the systematic 45% overestimation shifted many estimates across the 10 kg/h threshold into the next regulatory bin. Notably, all misclassifications were off by only one bin, and most (26/29) were assigned to the higher bin rather than the lower, suggesting a conservative bias from a regulatory perspective.
2. Summary of Quantification and Categorization Performance of the Vehicle-Based Measurement System .
| site type | magnitude bin (kg/h) | num. meas. events | mean release rate (kg/h) | MAE (kg/h) | MAPE (%) | % correctly categorized |
|---|---|---|---|---|---|---|
| low-to-moderate complexity (CMC) | 0–1 | 54 | 0.24 | 0.19 | 100 | 94 |
| 1–10 | 18 | 1.78 | 0.58 | 34 | 83 | |
| high complexity (METEC) | 0–1 | 1 | 0.51 | 0.04 | 8 | 100 |
| 1–10 | 45 | 6.71 | 4.60 | 69 | 49 | |
| 10–100 | 12 | 13.70 | 4.34 | 31 | 100 |
Note: Results are grouped by site complexity and emission rate magnitude bin. MAE = mean absolute error; MAPE = mean absolute percentage error. The percentage correctly categorized represents the proportion of emission rate estimates that fell within the correct magnitude bin.
Although quantification performance degrades at high-complexity sites, this limitation should be considered in the context of LDAR requirements for the O&G site population. Under the amended Canadian oil and gas CH4 regulations, survey requirements include comprehensive inspections ranging from annually to quarterly for active sites, in addition to an annual third-party inspection and screening inspections multiple times per year at all sites. A spatial grouping analysis of active O&G infrastructure in Alberta indicates that approximately 75% of active sites are relatively simple well sites (containing five or fewer wells and no facilities), while an additional 10% of sites contain a single low-to moderate-complexity facility (e.g., single-well batteries, compressor stations, or field meter stations). Together, these sites account for roughly 85% of the active site population in the province and represent the types of low- to moderate-complexity sites where this method is expected to perform with minimal quantification bias.
Recent studies in Canada have found that OGI-based surveys miss a significant portion of total site-level emissions compared to aerial-based methods, , highlighting critical gaps in LDAR programs that rely primarily on OGI measurements and emphasizing the need for multiscale measurement approaches to capture the full emissions picture. In addition to demonstrating comparable or greater detection sensitivity and superior quantification performance than OGI, vehicle-based surveys offer several practical advantages that could address these gaps. At less than 10 min per site, vehicle-based surveys are significantly faster than OGI, where site-level survey durations can range from 1 to 2 h for satellite well pads to several days for large facilities, enabling broad coverage of the large population of sites required under regulations. The speed and scalability of vehicle-based surveys make them well-suited as a rapid-screening layer, flagging sites and source groups for targeted OGI follow-up and directing those resources to where they are most needed. Opportunities for operator-induced performance variability are also limited compared to OGI. Furthermore, unlike aerial surveys for which the quality of modeled wind speed data from third-party databases is a major contributor to uncertainty, the vehicle-based method measures wind continuously and locally near the point of emission, which is particularly important in complex environments. Limitations of this method include challenges in pinpointing individual leaking components, as well as constraints common to ground-based methods more broadly: site-access constraints, such as obstructions to full transects around a site, and unfavorable plume geometries arising from tall sources measured at close range. In certain cases, tall and highly complex sites may therefore be better suited for aerial survey methods. Taken together, these advantages and constraints suggest that vehicle-based surveys could serve as a valuable complement to, rather than replacement for, component-level OGI surveys and aerial approaches.
Beyond LDAR applications, vehicle-based measurement methods could help to fill a persistent gap in emission inventory development by increasing the number of low-level emitters that are directly measured. Emissions from oil and gas are well-documented to follow a heavy-tailed distribution, where a relatively small number of large emitters contribute disproportionately to total emissions. ,− However, low-level emitters remain an important and often underconsidered component of the inventory picture. Conrad et al. estimated that 24% of provincial CH4 emissions in Alberta originated from sources below the detection limit of the Bridger Photonics GML, with their bottom-up inventory relying primarily on equipment counts, emission factors, and historical OGI and hi-flow sampling data rather than direct measurements. Similarly, Williams et al. estimated that 30% of CH4 emissions from O&G sites across the contiguous United States originate from sources emitting less than 10 kg/h. Ravikumar et al. demonstrated that a detection limit of 0.1 kg/h is sufficient to maximize detected emissions from the O&G sector during periodic leak surveys, a threshold within the sensitivity demonstrated here with five site-perimeter transects. The performance demonstrated in this study, particularly the 90% PODevent threshold as low as 0.078 kg/h and the near-unbiased quantification performance at low-to-moderate-complexity sites, suggests that the vehicle-based method is well-suited to characterize the lower end of the emission distribution that aerial and satellite methods are likely to miss, with considerably less time and effort than methods of comparable detection sensitivity, such as QOGI, thereby reducing reliance on generic emission factors and limited component-level data.
Future work should focus on characterizing the influence of other parameters, such as measurement distance, on detection performance, validating quantification performance at higher source heights and emission rates, and developing reliable methods for the separation of overlapping plumes from closely colocated sources to address overestimation at high-complexity sites. Together, these advances would further establish vehicle-based measurements as a high-performance and reliable complement to existing CH4 measurement approaches.
Supplementary Material
Acknowledgments
This work was supported by the Natural Sciences and Engineering Research Council of Canada (NSERC, Grant ALLRP 568565–2021). Controlled-release experiments at the Carbon Management Canada (CMC) facility were supported by the Alberta Methane Emissions Program (AMEP; Agreement TD020), while experiments at the Methane Emissions Technology Evaluation Center (METEC) were funded by Eotrac Inc.
The Supporting Information is available free of charge at https://pubs.acs.org/doi/10.1021/acsestair.6c00216.
Input parameter selection for spike detection algorithm (S1); limitations of the attribution algorithm (S2); factors influencing detection probability (S3); and additional tables and figures (PDF)
The authors declare the following competing financial interest(s): D.R. holds a minor ownership interest in Eosense Inc., which owns Eotrac, the company holding commercial rights to the vehicle-based measurement system in oil and gas applications. D.R. is not involved in the business of either company and is considered "at arms length" from their activities by Canadian granting agencies like NSERC. C.V.N is an employee of Eotrac Inc. The remaining authors declare no competing financial interest.
∥.
J.V.J. deceased on October 9th, 2025.
References
- Forster, P. ; Storelvmo, T. ; Armour, K. ; Collins, W. ; Dufresne, J.-L. ; Frame, D. ; Lunt, D. J. ; Mauritsen, T. ; Palmer, T. ; Watanabe, M. ; Zhang, H. . The Earth’s Energy Budget, Climate Feedbacks, and Climate Sensitivity. In Climate Change 2021 – The Physical Science Basis: Working Group I Contribution to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change; Cambridge University Press:Cambridge, United Kingdom and New York, NY, USA, 2021; pp 923–1054 10.1017/9781009157896. [DOI] [Google Scholar]
- Environment and Climate Change Canada (ECCC) . National Inventory Report 1990–2024: Greenhouse Gas Sources and Sinks in Canada ; Government of Canada, 2026. canada.ca/ghg-inventory
- Saunois M., Martinez A., Poulter B., Zhang Z., Raymond P. A., Regnier P., Canadell J. G., Jackson R. B., Patra P. K., Bousquet P., Ciais P., Dlugokencky E. J., Lan X., Allen G. H., Bastviken D., Beerling D. J., Belikov D. A., Blake D. R., Castaldi S., Crippa M., Deemer B. R., Dennison F., Etiope G., Gedney N., Höglund-Isaksson L., Holgerson M. A., Hopcroft P. O., Hugelius G., Ito A., Jain A. K., Janardanan R., Johnson M. S., Kleinen T., Krummel P. B., Lauerwald R., Li T., Liu X., McDonald K. C., Melton J. R., Mühle J., Müller J., Murguia-Flores F., Niwa Y., Noce S., Pan S., Parker R. J., Peng C., Ramonet M., Riley W. J., Rocher-Ros G., Rosentreter J. A., Sasakawa M., Segers A., Smith S. J., Stanley E. H., Thanwerdas J., Tian H., Tsuruta A., Tubiello F. N., Weber T. S., van der Werf G. R., Worthy D. E. J., Xi Y., Yoshida Y., Zhang W., Zheng B., Zhu Q., Zhu Q., Zhuang Q.. Global Methane Budget 2000–2020. Earth Syst. Sci. Data. 2025;17(5):1873–1958. doi: 10.5194/essd-17-1873-2025. [DOI] [Google Scholar]
- Ocko I. B., Sun T., Shindell D., Oppenheimer M., Hristov A. N., Pacala S. W., Mauzerall D. L., Xu Y., Hamburg S. P.. Acting Rapidly to Deploy Readily Available Methane Mitigation Measures by Sector Can Immediately Slow Global Warming. Environ. Res. Lett. 2021;16(5):054042. doi: 10.1088/1748-9326/abf9c8. [DOI] [Google Scholar]
- U.S. Environmental Protection Agency (EPA) . Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review. Federal Register 2024, 89, 16820-16984. https://www.federalregister.gov/d/2024-00366.
- Government of Canada . Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector). Canada Gazette, Part 2 2018, Vol. 152, SOR/2018-66. https://gazette.gc.ca/rp-pr/p2/2018/2018-04-26-x1/html/sor-dors66-eng.html [Google Scholar]
- Government of Canada . Regulations Amending the Regulations Respecting Reduction in the Release of Methane and Certain Volatile Organic Compounds (Upstream Oil and Gas Sector). Canada Gazette, Part 2 2025, Vol. 159, SOR/2025-280. https://gazette.gc.ca/rp-pr/p2/2025/2025-12-31/html/sor-dors280-eng.html. [Google Scholar]
- European Parliament, Council of the European Union . Regulation (EU) 2024/1787 of the European Parliament and of the Council on the Reduction of Methane Emissions in the Energy Sector and Amending Regulation (EU) 2019/942. Off. J. Eur. Union 2024, L 2024/1787. https://eur-lex.europa.eu/eli/reg/2024/1787.
- Alberta Energy Regulator (AER) . Directive 060: Upstream Petroleum Industry Flaring, Incinerating, and Venting ;2025. https://www.aer.ca/regulations-and-compliance-enforcement/rules-and-regulations/directives/directive-060.
- Daniels W. S., Wang J. L., Ravikumar A. P., Harrison M., Roman-White S. A., George F. C., Hammerling D. M.. Toward Multiscale Measurement-Informed Methane Inventories: Reconciling Bottom-Up Site-Level Inventories with Top-Down Measurements Using Continuous Monitoring Systems. Environ. Sci. Technol. 2023;57(32):11823–11833. doi: 10.1021/acs.est.3c01121. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Fox T. A., Barchyn T. E., Risk D., Ravikumar A. P., Hugenholtz C. H.. A Review of Close-Range and Screening Technologies for Mitigating Fugitive Methane Emissions in Upstream Oil and Gas. Environ. Res. Lett. 2019;14(5):053002. doi: 10.1088/1748-9326/ab0cc3. [DOI] [Google Scholar]
- Wilde S. E., Tyner D. R., Johnson M. R.. The Efficacy of Methane Leak Detection and Repair (LDAR) Programs in Practice. ACS EST Air. 2025;2(11):2527–2536. doi: 10.1021/acsestair.5c00195. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Conrad B. M., Tyner D. R., Johnson M. R.. Robust Probabilities of Detection and Quantification Uncertainty for Aerial Methane Detection: Examples for Three Airborne Technologies. Remote Sens. Environ. 2023;288:113499. doi: 10.1016/j.rse.2023.113499. [DOI] [Google Scholar]
- Ravikumar A. P., Sreedhara S., Wang J., Englander J., Roda-Stuart D., Bell C., Zimmerle D., Lyon D., Mogstad I., Ratner B., Brandt A. R.. Single-Blind Inter-Comparison of Methane Detection Technologies – Results from the Stanford/EDF Mobile Monitoring Challenge. Elem. Sci. Anthr. 2019;7:37. doi: 10.1525/elementa.373. [DOI] [Google Scholar]
- Zimmerle D., Vaughn T., Bell C., Bennett K., Deshmukh P., Thoma E.. Detection Limits of Optical Gas Imaging for Natural Gas Leak Detection in Realistic Controlled Conditions. Environ. Sci. Technol. 2020;54(18):11506–11514. doi: 10.1021/acs.est.0c01285. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Caulton D. R., Lu J. M., Lane H. M., Buchholz B., Fitts J. P., Golston L. M., Guo X., Li Q., McSpiritt J., Pan D., Wendt L., Bou-Zeid E., Zondlo M. A.. Importance of Superemitter Natural Gas Well Pads in the Marcellus Shale. Environ. Sci. Technol. 2019;53(9):4747–4754. doi: 10.1021/acs.est.8b06965. [DOI] [PubMed] [Google Scholar]
- Korbeń P., Jagoda P., Maazallahi H., Kammerer J., Nęcki J. M., Wietzel J. B., Bartyzel J., Radovici A., Zavala-Araiza D., Röckmann T., Schmidt M.. Quantification of Methane Emission Rate from Oil and Gas Wells in Romania Using Ground-Based Measurement Techniques. Elem. Sci. Anthr. 2022;10(1):00070. doi: 10.1525/elementa.2022.00070. [DOI] [Google Scholar]
- MacKay K., Lavoie M., Bourlon E., Atherton E., O’Connell E., Baillie J., Fougère C., Risk D.. Methane Emissions from Upstream Oil and Gas Production in Canada Are Underestimated. Sci. Rep. 2021;11(1):8041. doi: 10.1038/s41598-021-87610-3. [DOI] [PMC free article] [PubMed] [Google Scholar]
- O’Connell E., Risk D., Atherton E., Bourlon E., Fougère C., Baillie J., Lowry D., Johnson J.. Methane Emissions from Contrasting Production Regions within Alberta, Canada: Implications under Incoming Federal Methane Regulations. Elem. Sci. Anthr. 2019;7:3. doi: 10.1525/elementa.341. [DOI] [Google Scholar]
- Zhou X., Yoon S., Mara S., Falk M., Kuwayama T., Tran T., Cheadle L., Nyarady J., Croes B., Scheehle E., Herner J. D., Vijayan A.. Mobile Sampling of Methane Emissions from Natural Gas Well Pads in California. Atmos. Environ. 2021;244:117930. doi: 10.1016/j.atmosenv.2020.117930. [DOI] [Google Scholar]
- Ars S., Vogel F., Arrowsmith C., Heerah S., Knuckey E., Lavoie J., Lee C., Pak N. M., Phillips J. L., Wunch D.. Investigation of the Spatial Distribution of Methane Sources in the Greater Toronto Area Using Mobile Gas Monitoring Systems. Environ. Sci. Technol. 2020;54(24):15671–15679. doi: 10.1021/acs.est.0c05386. [DOI] [PubMed] [Google Scholar]
- Tettenborn J., Zavala-Araiza D., Stroeken D., Maazallahi H., Van Der Veen C., Hensen A., Velzeboer I., Van Den Bulk P., Vogel F., Gillespie L., Ars S., France J., Lowry D., Fisher R., Röckmann T.. Improving Consistency in Methane Emission Quantification from the Natural Gas Distribution Systems across Measurement Devices. Atmos. Meas. Technol. 2025;18(14):3569–3584. doi: 10.5194/amt-18-3569-2025. [DOI] [Google Scholar]
- Vogel F., Ars S., Wunch D., Lavoie J., Gillespie L., Maazallahi H., Röckmann T., Nęcki J., Bartyzel J., Jagoda P., Lowry D., France J., Fernandez J., Bakkaloglu S., Fisher R., Lanoiselle M., Chen H., Oudshoorn M., Yver-Kwok C., Defratyka S., Morgui J. A., Estruch C., Curcoll R., Grossi C., Chen J., Dietrich F., Forstmaier A., Denier Van Der Gon H. A. C., Dellaert S. N. C., Salo J., Corbu M., Iancu S. S., Tudor A. S., Scarlat A. I., Calcan A.. Ground-Based Mobile Measurements to Track Urban Methane Emissions from Natural Gas in 12 Cities across Eight Countries. Environ. Sci. Technol. 2024;58(5):2271–2281. doi: 10.1021/acs.est.3c03160. [DOI] [PMC free article] [PubMed] [Google Scholar]
- von Fischer J. C., Cooley D., Chamberlain S., Gaylord A., Griebenow C. J., Hamburg S. P., Salo J., Schumacher R., Theobald D., Ham J.. Rapid, Vehicle-Based Identification of Location and Magnitude of Urban Natural Gas Pipeline Leaks. Environ. Sci. Technol. 2017;51(7):4091–4099. doi: 10.1021/acs.est.6b06095. [DOI] [PubMed] [Google Scholar]
- Weller Z. D., Yang D. K., Von Fischer J. C.. An Open Source Algorithm to Detect Natural Gas Leaks from Mobile Methane Survey Data. PLoS One. 2019;14(2):e0212287. doi: 10.1371/journal.pone.0212287. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Luetschwager E., Von Fischer J. C., Weller Z. D.. Characterizing Detection Probabilities of Advanced Mobile Leak Surveys. Elem. Sci. Anthr. 2021;9(1):00143. doi: 10.1525/elementa.2020.00143. [DOI] [Google Scholar]
- Wietzel J. B., Korben P., Hoheisel A., Schmidt M.. Best Practices and Uncertainties in CH4 Emission Quantification: Employing Mobile Measurements and Gaussian Plume Modelling at a Biogas Plant. Atmos. Meas. Tech. 2025;18(18):4631–4645. doi: 10.5194/amt-18-4631-2025. [DOI] [Google Scholar]
- Gillespie L. D., Ars S., Alkadri S., Urya S., Khoo T., Fraser S., Vogel F., Wunch D.. Estimating Methane Emissions from the Waste Sector in Southern Ontario Using Atmospheric Measurements. J. Air Waste Manag. Assoc. 2025;75(2):144–163. doi: 10.1080/10962247.2024.2435340. [DOI] [PubMed] [Google Scholar]
- Liu Y., Paris J.-D., Broquet G., Bescós Roy V., Meixus Fernandez T., Andersen R., Russu Berlanga A., Christensen E., Courtois Y., Dominok S., Dussenne C., Eckert T., Finlayson A., Fernández De La Fuente A., Gunn C., Hashmonay R., Grigoleto Hayashi J., Helmore J., Honsel S., Innocenti F., Irjala M., Log T., Lopez C., Cortés Martínez F., Martinez J., Massardier A., Nygaard H. G., Agregan Reboredo P., Rousset E., Scherello A., Ulbricht M., Weidmann D., Williams O., Yarrow N., Zarea M., Ziegler R., Sciare J., Vrekoussis M., Bousquet P.. Assessment of Current Methane Emission Quantification Techniques for Natural Gas Midstream Applications. Atmos. Meas. Technol. 2024;17(6):1633–1649. doi: 10.5194/amt-17-1633-2024. [DOI] [Google Scholar]
- Kumar P., Broquet G., Yver-Kwok C., Laurent O., Gichuki S., Caldow C., Cropley F., Lauvaux T., Ramonet M., Berthe G., Martin F., Duclaux O., Juery C., Bouchet C., Ciais P.. Mobile Atmospheric Measurements and Local-Scale Inverse Estimation of the Location and Rates of Brief CH4 and CO2 Releases from Point Sources. Atmos. Meas. Technol. 2021;14(9):5987–6003. doi: 10.5194/amt-14-5987-2021. [DOI] [Google Scholar]
- Kumar P., Broquet G., Caldow C., Laurent O., Gichuki S., Cropley F., Yver-Kwok C., Fontanier B., Lauvaux T., Ramonet M., Shah A., Berthe G., Martin F., Duclaux O., Juery C., Bouchet C., Pitt J., Ciais P.. Near-field Atmospheric Inversions for the Localization and Quantification of Controlled Methane Releases Using Stationary and Mobile Measurements. Q. J. R. Meteorol. Soc. 2022;148(745):1886–1912. doi: 10.1002/qj.4283. [DOI] [Google Scholar]
- Tian S., Riddick S. N., Cho Y., Bell C. S., Zimmerle D. J., Smits K. M.. Investigating Detection Probability of Mobile Survey Solutions for Natural Gas Pipeline Leaks under Different Atmospheric Conditions. Environ. Pollut. 2022;312:120027. doi: 10.1016/j.envpol.2022.120027. [DOI] [PubMed] [Google Scholar]
- Rao G. V., Aldred J. R., Zimmerle D. J., Smits K. M.. Understanding Detection Success of Belowground Natural Gas Leaks in Urban Environments through Controlled Release Experiments. J. Pipeline Sci. Eng. 2026;6(4):100417. doi: 10.1016/j.jpse.2025.100417. [DOI] [Google Scholar]
- Ilonze C., Day R., Emerson E., Duggan A., Brouwer R., Zimmerle D.. Performance Evaluation of Survey Solutions in Detecting and Localizing Source-Level Emissions Using a Single-Blind Controlled Testing Protocol. Environ. Sci. Technol. 2026;60(1):459–472. doi: 10.1021/acs.est.5c11814. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Turner D. B.. A Diffusion Model for an Urban Area. J. Appl. Meteorol. 1964;3:83–91. doi: 10.1175/1520-0450(1964)003<0083:ADMFAU>2.0.CO;2. [DOI] [Google Scholar]
- Liland K. H.. 4S Peak Filling – Baseline Estimation by Iterative Mean Suppression. MethodsX. 2015;2:135–140. doi: 10.1016/j.mex.2015.02.009. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Daniels W. S., Jia M., Hammerling D. M.. Detection, Localization, and Quantification of Single-Source Methane Emissions on Oil and Gas Production Sites Using Point-in-Space Continuous Monitoring Systems. Elem. Sci. Anthr. 2024;12(1):00110. doi: 10.1525/elementa.2023.00110. [DOI] [Google Scholar]
- Seinfeld, J. H. ; Pandis, S. N. . Atmospheric Chemistry and Physics: From Air Pollution to Climate Change, 1st ed.; New York Academy of Sciences Series; John Wiley & Sons, Incorporated: Newark, 2016. [Google Scholar]
- Turner, D. B. Workbook of Atmospheric Dispersion Estimates; U.S. Environmental Protection Agency: Research Triangle Park, NC, 1970.
- Caulton D. R., Li Q., Bou-Zeid E., Fitts J. P., Golston L. M., Pan D., Lu J., Lane H. M., Buchholz B., Guo X., McSpiritt J., Wendt L., Zondlo M. A.. Quantifying Uncertainties from Mobile-Laboratory-Derived Emissions of Well Pads Using Inverse Gaussian Methods. Atmos. Chem. Phys. 2018;18(20):15145–15168. doi: 10.5194/acp-18-15145-2018. [DOI] [Google Scholar]
- Methane Emission Technology Evaluation Center (METEC) and TotalEnergies Anomalies Detection Initiatives (TADI) . Controlled Test Protocol, Emission Detection and Quantification Protocol, Version 1.0. 2025, https://metec.colostate.edu/aded-2-0/
- Eotrac Incorporated . Characterizing the Performance of a Mobile Methane Detection Platform: Insights from Controlled Release Testing in Alberta; Calgary, AB, Canada, 2025. https://www.eotrac.com/news/vehicle-mounted-methane-detection-whitepaper
- Bell C., Rutherford J., Brandt A., Sherwin E., Vaughn T., Zimmerle D.. Single-Blind Determination of Methane Detection Limits and Quantification Accuracy Using Aircraft-Based LiDAR. Elem. Sci. Anthr. 2022;10(1):00080. doi: 10.1525/elementa.2022.00080. [DOI] [Google Scholar]
- El Abbadi S. H., Chen Z., Burdeau P. M., Rutherford J. S., Chen Y., Zhang Z., Sherwin E. D., Brandt A. R.. Technological Maturity of Aircraft-Based Methane Sensing for Greenhouse Gas Mitigation. Environ. Sci. Technol. 2024;58(22):9591–9600. doi: 10.1021/acs.est.4c02439. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Bell C., Ilonze C., Duggan A., Zimmerle D.. Performance of Continuous Emission Monitoring Solutions under a Single-Blind Controlled Testing Protocol. Environ. Sci. Technol. 2023;57(14):5794–5805. doi: 10.1021/acs.est.2c09235. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Ilonze C., Emerson E., Duggan A., Zimmerle D.. Assessing the Progress of the Performance of Continuous Monitoring Solutions under a Single-Blind Controlled Testing Protocol. Environ. Sci. Technol. 2024;58(25):10941–10955. doi: 10.1021/acs.est.3c08511. [DOI] [PMC free article] [PubMed] [Google Scholar]
- McManemin A., Juéry C., Blandin V., France J. L., Burdeau P., Brandt A. R.. Controlled Release Testing of Commercially Available Methane Emission Measurement Technologies at the TADI Facility. Atmos. Meas. Technol. 2026;19(3):923–934. doi: 10.5194/amt-19-923-2026. [DOI] [Google Scholar]
- Sherwin E. D., Rutherford J. S., Chen Y., Aminfard S., Kort E. A., Jackson R. B., Brandt A. R.. Single-Blind Validation of Space-Based Point-Source Detection and Quantification of Onshore Methane Emissions. Sci. Rep. 2023;13(1):3836. doi: 10.1038/s41598-023-30761-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Sherwin E. D., El Abbadi S. H., Burdeau P. M., Zhang Z., Chen Z., Rutherford J. S., Chen Y., Brandt A. R.. Single-Blind Test of Nine Methane-Sensing Satellite Systems from Three Continents. Atmos. Meas. Technol. 2024;17(2):765–782. doi: 10.5194/amt-17-765-2024. [DOI] [Google Scholar]
- Singh, D. ; Barlow, B. ; Hugenholtz, C. ; Funk, W. ; Robinson, C. ; Ravikumar, A. . Field Performance of New Methane Detection Technologies: Results from the Alberta Methane Field Challenge, preprint Oil, Gas, Energy 2021. 10.31223/X5GS46. [DOI]
- Ilonze C., Wang J. Lyra., Ravikumar A. P., Zimmerle D.. Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment. Sensors. 2024;24(13):4044. doi: 10.3390/s24134044. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Tyner D. R., Johnson M. R.. Where the Methane IsInsights from Novel Airborne LiDAR Measurements Combined with Ground Survey Data. Environ. Sci. Technol. 2021;55(14):9773–9783. doi: 10.1021/acs.est.1c01572. [DOI] [PubMed] [Google Scholar]
- Ravikumar A. P., Roda-Stuart D., Liu R., Bradley A., Bergerson J., Nie Y., Zhang S., Bi X., Brandt A. R.. Repeated Leak Detection and Repair Surveys Reduce Methane Emissions over Scale of Years. Environ. Res. Lett. 2020;15(3):034029. doi: 10.1088/1748-9326/ab6ae1. [DOI] [Google Scholar]
- Conrad B. M., Johnson M. R.. Accounting for Spatiotemporally Correlated Errors in Wind Speed for Remote Surveys of Methane Emissions. Atmos. Meas. Technol. 2026;19(11):3761–3780. doi: 10.5194/amt-19-3761-2026. [DOI] [Google Scholar]
- Alvarez R. A., Zavala-Araiza D., Lyon D. R., Allen D. T., Barkley Z. R., Brandt A. R., Davis K. J., Herndon S. C., Jacob D. J., Karion A., Kort E. A., Lamb B. K., Lauvaux T., Maasakkers J. D., Marchese A. J., Omara M., Pacala S. W., Peischl J., Robinson A. L., Shepson P. B., Sweeney C., Townsend-Small A., Wofsy S. C., Hamburg S. P.. Assessment of Methane Emissions from the U.S. Oil and Gas Supply Chain. Science. 2018;361:eaar7204. doi: 10.1126/science.aar7204. [DOI] [PMC free article] [PubMed] [Google Scholar]
- Brandt A. R., Heath G. A., Cooley D.. Methane Leaks from Natural Gas Systems Follow Extreme Distributions. Environ. Sci. Technol. 2016;50(22):12512–12520. doi: 10.1021/acs.est.6b04303. [DOI] [PubMed] [Google Scholar]
- Williams J. P., Omara M., Himmelberger A., Zavala-Araiza D., MacKay K., Benmergui J., Sargent M., Wofsy S. C., Hamburg S. P., Gautam R.. Small Emission Sources in Aggregate Disproportionately Account for a Large Majority of Total Methane Emissions from the US Oil and Gas Sector. Atmos. Chem. Phys. 2025;25(3):1513–1532. doi: 10.5194/acp-25-1513-2025. [DOI] [Google Scholar]
- Conrad B. M., Tyner D. R., Li H. Z., Xie D., Johnson M. R.. A Measurement-Based Upstream Oil and Gas Methane Inventory for Alberta, Canada Reveals Higher Emissions and Different Sources than Official Estimates. Commun. Earth Environ. 2023;4(1):416. doi: 10.1038/s43247-023-01081-0. [DOI] [Google Scholar]
- Ravikumar A. P., Wang J., McGuire M., Bell C. S., Zimmerle D., Brandt A. R.. "Good versus Good Enough?” Empirical Tests of Methane Leak Detection Sensitivity of a Commercial Infrared Camera. Environ. Sci. Technol. 2018;52(4):2368–2374. doi: 10.1021/acs.est.7b04945. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.