Skip to main content

This is a preprint.

It has not yet been peer reviewed by a journal.

The National Library of Medicine is running a pilot to include preprints that result from research funded by NIH in PMC and PubMed.

medRxiv logoLink to medRxiv
[Preprint]. 2026 Nov 7:2026.02.23.26346855. [Version 2] doi: 10.64898/2026.02.23.26346855

Dense Breast Tissue Segmentation under Limited Annotation: Comparing CNNs, Transformers, Self-Supervision, and Prompting

Bowen Qu, Weixin Liu, Li Zhou, Xingyi Guo, Bradley Malin, Zhijun Yin
PMCID: PMC13780906  PMID: 43060765

Abstract

Dense breast tissue reduces the sensitivity of mammographic screening and is an important risk factor for breast cancer, making accurate dense-tissue segmentation particularly important when expert pixel-level annotations are limited. We empirically study dense breast tissue segmentation under limited pixel-level supervision using a small expert-annotated dataset (596 images) together with an in-domain unlabeled mammography dataset (20,000 images). We compare classical pixel-level segmentation methods, CNN and U-Net encoder–decoder models, transformer-based models, self-supervised pre-training, fine-tuning strategies, loss functions, and prompt-based MedSAM variants under a unified evaluation protocol. CNN-based models achieve the best standalone segmentation performance while providing the most favorable balance between accuracy and computational cost. In contrast, the adaptive fuzzy c-means + SVM baseline and transformer-based models perform worse in this low-label setting. Our analysis of prompt-based MedSAM further shows that SAM-style models are highly sensitive to prompt quality. Box and breast-region prompts lead to poor performance, whereas CNN-generated dense prompts substantially improve MedSAM performance. However, even with mask-decoder fine-tuning, CNN-prompted MedSAM does not outperform the best standalone CNN model, suggesting that current SAM-style models require stronger prompts or adaptation beyond the mask decoder for diffuse breast-density segmentation. Additionally, a density-calibrated hybrid loss primarily improves percentdensity calibration by reducing the test MAE from 14.8 to 11.8 percentage points. Our computational cost analysis indicates that many generic self-supervised learning and parameter-efficient adaptation strategies provide limited practical benefit relative to their additional cost. These findings offer practical guidance for developing reproducible dense breast tissue segmentation models in mammography studies with limited labeled data.

Full Text Availability

The license terms selected by the author(s) for this preprint version do not permit archiving in PMC. The full text is available from the preprint server.


Articles from medRxiv are provided here courtesy of Cold Spring Harbor Laboratory Preprints

RESOURCES