Skip to main content
Springer logoLink to Springer
. 2026 Nov 18;65(8):304. doi: 10.1007/s00394-026-04170-w

Intragastric administration of the bitter tastant, quinine, reduces postprandial plasma glucose without affecting gastric emptying in health

Parivash Ghorbaninejad 1,2,#, Maedeh Moradi 1,3,4,#, Vida Bitarafan 1,2, Penelope CE Fitzgerald 1,2, Braden D Rose 1,2,3, Javad Anjom-Shoae 1,2, Seva Hatzinikolas 1,2, Karen L Jones 1,2,5,6, Michael Horowitz 1,2,5, Christine Feinle-Bisset 1,2,✉
PMCID: PMC13782012  PMID: 43049790

Abstract

Purpose

In health and type 2 diabetes, intraluminal administration of quinine stimulates glucoregulatory hormones and slows gastric emptying, key determinants of postprandial plasma glucose, following oral carbohydrate. We have now investigated these effects following a mixed solid-liquid meal, with gastric emptying quantified using scintigraphy, the ‘gold-standard’ technique.

Methods

On three separate days, nine middle-aged individuals without diabetes (age: 51 ± 8 years) received 0 (‘control’), 300 (‘Q300’) or 600 (‘Q600’) mg quinine hydrochloride intragastrically, 60 min before a standardised mixed solid-liquid meal (100 g beef burger radiolabelled with 99mTc-phytate and 150 mL 10% glucose drink radiolabelled with 67Ga-EDTA), in randomised, double-blind fashion. Plasma glucose, insulin and glucagon were measured at baseline, for 60 min before, and for 120 min after, the meal. Gastric emptying was measured using scintigraphy. Data were analysed using repeated-measures ANOVA.

Results

Q600 and Q300 both reduced plasma glucose immediately before the meal, at t=–5 min, as well as overall and peak postprandial glucose, when compared with control, in a dose-dependent manner (P < 0.05). Q600 stimulated plasma insulin before the meal at t=–20 min (P = 0.04), and the postprandial plasma insulin-to-glucose ratio (P = 0.02), compared with control. Both overall and peak postprandial plasma glucose were inversely related to plasma insulin at t=–20 min (R<–0.51, P < 0.05). Quinine did not affect plasma glucagon or gastric emptying.

Conclusion

Intragastric quinine lowers the plasma glucose response to a mixed solid-liquid meal in middle-aged individuals without diabetes by stimulating preprandial insulin, without affecting either plasma glucagon or gastric emptying.

Trial registration

The study was registered as a clinical trial with the Australian and New Zealand Clinical Trials Registry (https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=383933&isReview=true; ACTRN12622000735752, date of registration: May 23, 2022).

Keywords: Bitter substance, Glycaemia, Glucoregulatory hormones, Postprandial blood glucose, Human

Introduction

Bitter compounds activate distinct chemoreceptors on enteroendocrine cells to trigger the release of key gut and pancreatic glucoregulatory hormones and modulate gut motility, associated with postprandial glucose lowering [1–3]. Among these compounds, quinine has attracted particular interest and been the most extensively studied in humans. It was initially administered intravenously, usually in a dose of 500 mg for treatment of malaria, which induced hypoglycaemia in some patients, possibly through direct stimulation of insulin secretion [4, 5]. More recently, interest in quinine has re-emerged, particularly in light of its potential glucose-lowering effect in type 2 diabetes (T2D) – intraluminal administration of quinine has been reported to stimulate plasma glucagon-like peptide-1 (GLP-1) and insulin, modestly increase glucagon, and also slow gastric emptying [6], key regulators of postprandial glycaemia.

We reported that in males without diabetes, intragastric administration of 275–600 mg quinine hydrochloride (QHCl) lowered postprandial plasma glucose, associated with stimulation of GLP-1 and insulin, although it did not affect gastric emptying of a mixed-nutrient drink (containing 74 g carbohydrate) consumed 30 min later [7]. In males and females without diabetes, a lower dose of 18 mg QHCl, delivered in an acid-resistant capsule to achieve duodenal release, also had no effect on gastric emptying of a solid meal consumed 60 min after administration [8]. In contrast, increasing the exposure of small intestinal bitter receptors to 600 mg QHCl administered intragastrically, or intraduodenally, 60 or 30 min before a mixed-nutrient drink, respectively, resulted in greater lowering of plasma glucose, at least in part, due to greater stimulation of both insulin and GLP-1 and slowing of gastric emptying [9]. Thus, optimisation of the dose and route of quinine administration may be required to modulate gut function effectively to maximise postprandial glucose lowering.

Previous studies assessed the effect of quinine on gastric emptying predominantly following liquid meals, using a validated 13C-acetate or 13C-octanoic acid breath test, a non-invasive, but indirect, technique that is dependent on a number of factors, including small intestinal and hepatic functions, other than gastric emptying per se [10]. However, there is no information relating to the effects of quinine on gastric emptying assessed by scintigraphy, the ‘gold standard’ method, which allows precise assessment of both liquid and solid gastric emptying, including quantification of intragastric retention over time [11, 12]. Accordingly, we have investigated the effects of intragastric quinine on glucoregulatory responses to, and gastric emptying of, a mixed solid-liquid meal using scintigraphy in individuals without diabetes.

Subjects, materials and methods

Participants

Nine lean middle-aged individuals without diabetes (3 males, 6 females, age (mean ± SD): 51 ± 8 years, BMI (mean ± SD): 22.3 ± 2.3 kg/m2) were studied. The participant flow chart is shown in Fig. 1. Participants were recruited from an existing database within the Adelaide Medical School, and through flyers placed across local universities (University of Adelaide, University of South Australia and Flinders University) and the Royal Adelaide Hospital. Further recruitment was conducted via online advertisements on the University job sites, Gumtree, Adzuna, and other official job boards, in addition to paid social media advertising, including Facebook. The selection of participants aged 40–80 years was based on radiation safety requirements relating to the use of scintigraphy in health [13]. Participants were screened before enrolment and excluded if they reported gastrointestinal (GI) symptoms or had a history of significant GI, cardiovascular or respiratory disease or surgery, oesophageal varices or strictures, epilepsy, coagulation abnormalities, intolerance of the nasogastric tube (tested in a screening session), difficulty understanding the study protocol, low plasma ferritin (females < 15 µg/L, males < 30 µg/L) or iron (< 8 µmol/L) levels (a requirement of the Human Research Ethics Committee), exposure to ionising radiation for research purposes within the past year, or blood donation within the previous 3 months. Participants were also excluded if they were known to be lactose-intolerant, current smokers or recreational drug users, followed a vegetarian diet, consumed > 20 g/day alcohol on > 5 days/week, used medications known to affect GI function, were high-performance athletes, had unstable body weight (≥ 5% change over the past 3 months), or had demonstrated restrained eating behaviour (score > 12 on the restrained eating component of the 3-factor eating questionnaire [14]). Pregnant, lactating and surgically sterilised females were also excluded. Premenopausal females were required to have a regular menstrual cycle and studied during the follicular phase to minimise the potential confounding effects of the menstrual cycle on gastric emptying and glucoregulatory hormones [15]. Participants were asked to maintain their usual physical activity throughout the study. Recruitment was stopped early as nine participants were calculated to be sufficient to demonstrate differences in the primary outcome (plasma glucose), and there was a lack of justification for recruiting additional participants, particularly given that the study involved intragastric intubation and exposure to ionising radiation.

Fig. 1.

Of 19 people assessed for eligibility, 5 were excluded: 1 vegetarian, 2 with a body mass index greater than 25 kilograms per square meter, 1 with iron deficiency, and 1 with gastrointestinal disease. The remaining 14 were randomised, allocated to the intervention, and received it. Before completing the first study visit, 4 withdrew for personal reasons and 1 did not tolerate the nasogastric tube. Nine participants were analysed.

CONSORT participant flow diagram

Written, informed consent was obtained from each participant before their inclusion. Following inclusion, participants were randomly allocated to one of three treatment sequences according to a 3 × 3 Latin Square design, using an online randomisation tool (https://www.sealedenvelope.com/) by a research officer not involved in data analysis. The study protocol was approved by the Human Research Ethics Committee of the Central Adelaide Local Health Network and conducted in accordance with the Declaration of Helsinki and the NHMRC Statement on Ethical Conduct in Human Research. The trial was registered with the Australian and New Zealand Clinical Trials Registry (https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=383933&isReview=true registration no. ACTRN12622000735752, date of registration: May 23, 2022).

Study design

This double-blind, randomised cross-over study investigated the effects of intragastric administration of QHCl in doses of 0 (‘control’), 300 (‘Q300’) or 600 (‘Q600’) mg (Fig. 2) on plasma glucose as a primary outcome, and gastric emptying of a mixed solid-liquid meal, plasma concentrations of insulin and glucagon and GI symptoms (nausea, bloating), as secondary outcomes. The selected doses were based on previous studies in which intragastric administration of 600 mg QHCl (equivalent to ~ 500 mg quinine, a dose used clinically for intravenous therapy of malaria) reduced plasma glucose and/or slowed gastric emptying [7, 9]. A lower dose of 300 mg QHCl (equivalent to ~ 250 mg quinine) was included to assess potential dose-dependent effects. The treatments were administered directly into the stomach via a nasogastric catheter to minimise potential confounding effects related to the bitter taste of quinine. QHCl was administered 60 min before the meal to optimise exposure to the small intestine [9].

Fig. 2.

Study timeline: Control or quinine was given at minus 60 minutes, followed by a solid-liquid meal at minus 5 minutes. Gastric emptying was measured from 0 to 120 minutes. Blood samples and visual analogue scale questionnaires were collected at minus 60, minus 40, minus 20, minus 5, 10, 20, 30, 45, 60, 75, 90 and 120 minutes.

Schematic diagram of the study design. At t =–60 min, a fasting blood sample was taken for the measurement of plasma glucose and hormone concentrations. Participants also completed a visual analogue scale (VAS) questionnaire to assess gastrointestinal symptoms, and then received an intragastric bolus of quinine hydrochloride in doses of 0 (control), 300 (Q300) or 600 (Q600) mg. At t=–5 min, participants consumed a mixed solid-liquid meal containing 100 g beef burger radiolabelled with 99mTc-phytate and 150 mL 10% glucose drink radiolabelled with 67Ga-EDTA, within 5 min (from t=–5 to 0 min). Gastric emptying of the solid-liquid meal was then measured using scintigraphy from t = 0 to 120 min. Blood samples and VAS questionnaires were collected at the times indicated. At t = 120 min, the intravenous cannula was removed, and the participant was free to leave the laboratory.

Preparation of treatments

The QHCl treatments were prepared by dissolving either 300 or 600 mg QHCl (Sinkona Indonesia Lestari, Subang, West Java, Indonesia) in 10 mL distilled water, while the control consisted of 10 mL distilled water alone. All solutions had a pH of ~ 7 and were prepared on the morning of each study visit by a research officer who was not involved in either the conduct of the studies or data analysis. The solutions were clear and visually indistinguishable; thus, both participants and investigators remained blinded to the nature of each treatment.

Study protocol

Each participant attended three study visits, separated by 3–7 days, in a randomised, crossover design. Participants were instructed to avoid vigorous physical activity and alcohol for 24 h before each visit. They were provided with a standardised meal (beef lasagne; energy content: 602 kcal; McCain Foods, Pty Ltd, Victoria, Australia) to be consumed by 7 pm the evening before each visit, following which they were required to fast from all food and beverages, except water, which was permitted until 7 am to maintain hydration. The next morning, each participant arrived at the Clinical Research Facility, Adelaide Health and Medical Sciences Building, Adelaide University, by 8.30 am. Female participants completed a urine pregnancy test before each visit.

Upon arrival, an intravenous cannula was inserted into a forearm vein, and the arm was kept warm with a heat pad to facilitate subsequent blood sampling for measurements of plasma glucose, insulin and glucagon. The participant was seated upright and intubated through an anaesthetised nostril with a custom-built, soft-silicone nasogastric feeding tube (outer diameter: 4 mm; Dentsleeve, Mississauga, Ontario, Canada), with the tip positioned in the stomach. At 9:00 am (i.e. t=–60 min), a fasting blood sample was collected for baseline measurement of plasma glucose, insulin and glucagon concentrations, the participant completed a visual analogue scale (VAS) questionnaire to assess GI symptoms (nausea, bloating) and then received an intragastric bolus of either QHCl or control within one minute, after which the nasogastric tube was removed. The participant was then seated with their back against the gamma camera. Blood samples were collected, and the participant completed VAS questionnaires at t=–40, t=–20, and t=–5 min. The participant was then given the mixed solid-liquid meal, which was consumed within 5 min (i.e. t=–5 to 0 min, where t = 0 min represented the time of meal completion). The meal comprised a 100 g minced beef burger (270 kcal, 25 g protein, 21 g fat), radiolabelled with 10 MBq 99mTc-phytate colloid, and 150 mL 10% dextrose (62 kcal), radiolabelled with 4 MBq 67Ga-EDTA [16, 17]. Gastric emptying of the solid and liquid meal components was measured for 2 h. Further blood samples and VAS questionnaires were collected at regular time points until t = 120 min (Fig. 2), when the intravenous cannula was removed, and the participant was offered a light lunch before leaving the laboratory.

Measurements

Plasma glucose, insulin and glucagon concentrations

Blood samples were collected into ice-chilled tubes containing ethylenediaminetetraacetic acid (EDTA). Samples were centrifuged at ~ 1832×g force for 15 min at 4 °C within 15 min of collection to obtain plasma, which was stored at − 80 °C until analysis. Plasma glucose concentrations (mmol/L) were measured by the glucose oxidase method using a glucose analyser (YSI 2300 Stat Plus, Yellow Springs Instruments, Yellow Springs, Ohio, USA). Plasma insulin (mU/L) and glucagon (pmol/L) concentrations were measured using human metabolic hormone multiplex assay kits (HMHEMAG-34 K; Merck Millipore, Abacus Diagnostics, Meadowbrook, QLD, Australia). Intra- and inter-assay CVs were < 10% and < 20% for insulin and glucagon respectively.

Gastric emptying

Gastric emptying data were recorded in 1-min frames for the first 60 min, followed by 3-min frames thereafter, until t = 120 min [18]. Gastric emptying curves, expressed as the percentage of the maximum total gastric content, were derived. The duration of the solid lag phase (i.e. the time before any of the solid meal had emptied from the stomach into the small intestine), the percentage of solid meal remaining in the stomach at 100 min (T100 min) and the 50% emptying time (T50) for liquid were also calculated [17, 18]. At the end of one of the study visits, the participant consumed 100 mL water radiolabelled with 4 MBq 99mTc-phytate colloid, and a lateral image of the stomach was acquired, which was used to derive correction factors for tissue attenuation. Data were also corrected for participant movement, radionuclide decay and down-scatter, as described previously [19].

GI symptoms

Nausea and bloating were assessed using a 100-mm VAS questionnaire [20]. Each VAS consisted of a 100-mm horizontal line, where 0 mm represented “sensation not felt at all” and 100 mm represented “sensation felt the greatest. At each assessment point, participants marked a vertical line on the scale to indicate the intensity of the sensation they were experiencing.

Data and statistical analysis

The number of participants was determined by power calculations for the primary outcome, plasma glucose, based on our previous study [21]. Thus, n = 9 participants were calculated to allow detection of a 1.5 mmol/L difference in plasma glucose, with a within-subject SD of 1.1 mmol/L. The power calculation assumed a significance level of α = 0.05, with a power of 80%.

Data for plasma glucose, insulin and glucagon and VAS scores were analysed using repeated measures two-way ANOVA with treatment (i.e. control, Q300, Q600), time (i.e. t=–60, − 40, − 20, and − 5 min for pre-meal, and t = 10, 20, 30, 45, 60, 75, 90, and 120 min for post-meal, data), and their interaction as fixed factors. Raw data were used to calculate total areas under the curve (AUCs) using the trapezoidal rule for plasma glucose, insulin, and glucagon concentrations from t = − 60 to − 5 min (AUC− 60 to −5 min; to assess the effects of treatment alone), t = − 5 to 30 min (AUC− 5 to 30 min; to assess the ‘early’ response to the meal) and t = − 5 to 120 min (AUC− 5 to 120 min; to assess the ‘overall’ response to the meal), and for gastric emptying data from t = 0–30 min (AUC0 to 30 min; ‘early’), and from t = 0–120 min (AUC0 to 120 min; ‘overall’). The plasma insulin-to-glucose ratio, as a measure of insulin secretion, was calculated by dividing the insulin AUC− 5 to 120 min by the glucose AUC− 5 to 120 min [22]. Peak plasma glucose, time to peak glucose, ‘early’ and ‘overall’ plasma glucose, plasma insulin-to-glucose ratio, lag phase and T100 min for solid meal, T50 for liquid meal, and gastric emptying profiles were analysed using one-way repeated measures ANOVA with treatment as a fixed factor. In the Results section, outcomes from treatment × time interactions or main effects, as applicable, are reported. Post-hoc comparisons, adjusted for multiple comparisons by Bonferroni’s correction, were performed when significant interactions or main effects were found. Sphericity of the repeated effects was evaluated by Mauchly’s test and, when violated, the adjusted Greenhouse–Geisser P-value was reported. Relationships among plasma glucose, insulin, glucagon, gastric emptying, and quinine dose were evaluated using linear within-subject correlation analysis [23]. All data are reported as means ± SEM. All tests were two-tailed, and differences were considered statistically significant at P < 0.05. Statistical analysis was performed with SPSS software (version 26.0; IBM, Chicago, IL, USA), and graphs were generated using GraphPad Prism (version 10.1.0 for Windows, GraphPad Software, Boston, Massachusetts USA).

Results

All nine participants completed all study visits and tolerated the study conditions well.

Plasma glucose concentrations

Response to quinine alone: There was a treatment × time interaction for plasma glucose (P < 0.001) (Table 1; Fig. 3A). At t=–20 min, plasma glucose was lower after Q600 compared with control (P < 0.001). At t=–5 min, plasma glucose was lower after Q600 (P < 0.001) and Q300 (P = 0.001) compared with control, and after Q600 compared with Q300 (P = 0.04).

Table 1.

Plasma glucose and gastric emptying, following intragastric administration of quinine hydrochloride in doses of 0 (control), 300 (Q300) or 600 (Q600) mg in individuals without diabetes

C Q300 Q600 P values
Plasma glucose
 Peak concentration (mmol/L) 7.3 ± 0.1 6.8 ± 0.2* 6.3 ± 0.1* < 0.001
 Time to peak (min) 40 ± 3 36 ± 3 36 ± 3 0.44
 AUC− 5 to 30 min (mmol/L×min) 195 ± 5 178 ± 7* 171 ± 7* 0.008
 AUC− 5 to 120 min (mmol/L×min) 695 ± 12 636 ± 22* 595 ± 14* < 0.001
 Plasma insulin-to-glucose ratio 9.0 ± 1.2 9.9 ± 1.5 11.5 ± 1.4* 0.01
Gastric emptying of solids
 Lag phase (min) 14 ± 2 14 ± 1 12 ± 2 0.58
 Intragastric retention at 100 min (%) 23.2 ± 6.9 20.6 ± 6.7 22.5 ± 7.3 0.44
Gastric emptying of liquids
 T50 (min) 36 ± 6 32 ± 5 36 ± 7 0.68

Data are means±SEMs; n = 9

AUC Area under the curve, C Control, Q300 quinine hydrochloride in a dose of 300 mg, Q600 Quinine hydrochloride in a dose of 600 mg

* significantly different from control (P < 0.05)

Fig. 3.

After the meal, glucose and insulin rose and then fell in all three groups, while glucagon rose later. Glucose was generally lower with quinine than with control, especially at 600 mg. Insulin was higher with 600 mg quinine than with control or 300 mg at some pre-meal time points. Glucagon followed a similar pattern across groups, reaching approximately 53 to 70 picomoles per litre by 120 minutes.

Plasma glucose (A), insulin (B) and glucagon (C) concentrations at baseline (i.e. t=–60 min), following intragastric administration of quinine hydrochloride in doses of 0 (control), 300 (Q300) or 600 (Q600) mg alone, and following a mixed solid-liquid meal, consumed at t=–5 min in individuals without diabetes. Data were analysed using repeated measures two-way ANOVA with treatment, time, and their interaction as fixed factors. Post-hoc comparisons, adjusted for multiple comparisons by Bonferroni’s correction, were conducted when significant interactions or main effects were found. (A) treatment × time interactions: # Q600 different from control (both P < 0.001), $ Q300 different from control (P = 0.001), & Q600 different from Q300 (P = 0.04); treatment effects: α Q600 different from control (P < 0.001), β Q300 different from control (P = 0.04). (B) treatment × time interactions: # Q600 different from control (P = 0.04), & Q600 different from Q300 (both P < 0.05). Data are expressed as means±SEMs; n = 9. C, control; Q300, quinine hydrochloride in a dose of 300 mg; Q600, quinine hydrochloride in a dose of 600 mg

Response to mixed solid-liquid meal: Plasma glucose increased on all study days (P < 0.001) (Table 1; Fig. 3A). There was an effect of treatment on plasma glucose (P < 0.001), which was lower after Q600 (P < 0.001) and Q300 (P = 0.04) compared with control, and non-significantly lower after Q600 compared with Q300 (P = 0.08).

There was an effect of treatment on peak plasma glucose (P < 0.001), which was lower after Q600 (P = 0.003) and Q300 (P = 0.04) compared with control, and non-significantly lower after Q600 compared with Q300 (P = 0.06). There was no effect of treatment on time to peak glucose (Table 1).

Plasma insulin concentrations

Response to quinine alone: There was a treatment × time interaction for plasma insulin (P = 0.001) (Fig. 3B). At t=–20 min, plasma insulin was greater after Q600 compared with control (P = 0.04) and Q300 (P = 0.01). At t=–5 min, plasma insulin was greater after Q600 compared with Q300 (P = 0.02).

Response to mixed solid-liquid meal: Plasma insulin increased on all study days (P = 0.006) (Fig. 3B). However, there was no effect of treatment on plasma insulin (P = 0.47).

Plasma insulin-to-glucose ratio

There was an effect of treatment on the plasma insulin-to-glucose ratio (P = 0.01), which was greater after Q600 compared with control (P = 0.02) (Table 1).

Plasma glucagon concentrations

There was no effect of treatment on plasma glucagon in response to quinine alone (P = 0.32) or the mixed solid-liquid meal (P = 0.23) (Fig. 3C). Plasma glucagon increased on all study days in response to the mixed solid-liquid meal (P < 0.001).

Gastric emptying

There was no effect of treatment on early or overall gastric emptying of either solid or liquid meal components (all P > 0.05), the intragastric retention of solid at 100 min (P = 0.44), T50 for liquid emptying (P = 0.68), or solid lag phase (P = 0.58) (Table 1; Fig. 4).

Fig. 4.

Liquid retention fell faster than solid retention across all three treatments. From 100 percent at the meal, solid retention declined to about 20 percent at 120 minutes, while liquid retention fell to about 5 to 8 percent. The control, 300 milligram, and 600 milligram quinine curves were similar for each meal component. Quinine or control was administered 60 minutes before the meal.

Intragastric retention of solid (a 100 g beef burger radiolabelled with 99mTc-phytate) and liquid (150 mL 10% glucose drink radiolabelled with 67Ga-EDTA) meal components, following intragastric administration of quinine hydrochloride in doses of 0 (control), 300 (Q300) or 600 (Q600) mg in individuals without diabetes. Data were analysed using repeated measures one-way ANOVA with treatment as a fixed factor. Data are expressed as means±SEMs; n = 9. C, control; Q300, quinine hydrochloride in a dose of 300 mg; Q600, quinine hydrochloride in a dose of 600 mg

GI symptoms

There was no effect of treatment on nausea or bloating in response to either quinine alone or the mixed solid-liquid meal (all P > 0.05) (data not shown).

Relationships among plasma glucose, insulin, glucagon, gastric emptying and quinine dose

There was an inverse relationship between the glucose AUC–60 to –5 min with the insulin AUC–60 to –5 min (R=–0.48, P = 0.03). There were also inverse relationships between peak plasma glucose (R=–0.51, P = 0.02), glucose AUC− 5 to 30 min (R=–0.58, P = 0.009) and glucose AUC− 5 to 120 min (R=–0.53, P = 0.03) with insulin at t=–20 min. There was an inverse relationship between the glucose AUC− 5 to 120 min with the glucagon AUC− 5 to 120 min (R=–0.56, P = 0.01). There were inverse relationships between plasma glucose at t=–5 min (R=–0.91, P < 0.001), glucose AUC− 5 to 120 min (R=–0.84, P < 0.001), and peak plasma glucose (R=–0.76, P < 0.001) with the dose of quinine.

Discussion

This study evaluated the dose-dependent effects of intragastric quinine on the glucoregulatory responses to, and gastric emptying of, a mixed solid-liquid meal in middle-aged individuals without diabetes. The principal findings were that quinine (i) stimulated plasma insulin and modestly lowered plasma glucose before the meal and (ii) increased the plasma insulin-to-glucose ratio and reduced postprandial glucose excursions following the meal, but (iii) did not affect plasma glucagon or gastric emptying. Accordingly, quinine appeared to exert its glucose-lowering effect through stimulation of insulin secretion. These findings provide important insights into the potential role of quinine in postprandial glucose regulation and may inform the development of novel quinine-based treatments to lower postprandial glycaemia.

We have demonstrated previously that intraluminal administration of quinine attenuates the glycaemic response to a carbohydrate-rich, mixed-nutrient drink in individuals with [6] and without [7, 9, 24] T2D. This glucose-lowering effect is associated with stimulation of plasma GLP-1, insulin and C-peptide, and/or slowing of gastric emptying – the latter evaluated using a stable isotope breath test. Based on these observations, we sought to determine whether similar effects would be observed following a mixed solid-liquid meal and when gastric emptying was quantified, using the ‘gold-standard’ technique of scintigraphy. In line with our previous observations [6, 7, 9, 24], quinine had a dose-dependent effect to reduce postprandial plasma glucose excursions following a solid-liquid meal, but did not slow gastric emptying of either solid or liquid meal components.

Glucoregulatory hormones, including insulin, glucagon and GLP-1, are key determinants of postprandial glucose [25]. While quinine stimulated insulin before the meal, insulin responses following the meal did not differ; however, the plasma insulin-to-glucose ratio was higher after the higher dose (Q600), indicative of insulin stimulation. Moreover, peak plasma glucose, as well as the ‘early’ and ‘overall’ glucose responses, correlated inversely with plasma insulin before the meal. These observations are consistent with our previous findings, in which peak postprandial glucose and/or early glucose responses were shown to be inversely related to pre-meal insulin following administration of either Q600 [24] or a combination of Q300 with the amino acids, leucine or isoleucine [21]. That quinine did not affect plasma glucagon is consistent with our previous reports of no or modest effects [6, 7]. GLP-1, which is known to slow gastric emptying and stimulate insulin secretion, the latter in a glucose-dependent manner, was not measured, as previous studies have demonstrated minimal, if any, stimulation of GLP-1 by quinine [6, 24]. Furthermore, the insulinotropic effect of GLP-1 typically requires plasma glucose concentrations to be > 8 mmol/L. As in the current study, mean plasma glucose concentrations did not exceed ~ 7.3 mmol/L, it is, therefore, most unlikely that GLP-1 contributed to the observed effects [26]. Furthermore, the absence of any effect on gastric emptying argues against significant stimulation of GLP-1. Accordingly, the observed insulinotropic effect of quinine is likely to be attributable to a direct action on pancreatic beta cells, rather than being mediated via stimulation of GLP-1.

The rate of gastric emptying is a key determinant of the postprandial glycaemic response, so that even modest alterations in the rate of nutrient delivery to the small intestine can affect postprandial plasma glucose excursions substantially [27]. Quinine did not affect either ‘early’ or ‘overall’ gastric emptying of solid or liquid meal components. While this appears to conflict with previous findings using a stable isotope breath test [6, 9, 24], a possibility is that quinine delayed small intestinal transit, as reported in a preclinical study [28]. While gastric emptying is highly reproducible in a given individual, there are substantial inter-individual variations in health [25]. The current study comprised predominantly females (6 out of 9), who may exhibit slower gastric emptying, particularly of solid meals, compared to males [29, 30]. Moreover, healthy ageing has been reported to be associated with a modest slowing of gastric emptying of both solids and liquids [31], as well as a reduced responsiveness to bitter compounds [32].

Limitations should be appreciated in interpreting our findings. Since only middle-aged individuals without diabetes were studied, our observations cannot be extrapolated confidently to either younger individuals or individuals with T2D. While the sample size was sufficiently powered for the primary outcome, our findings may warrant replication in a larger cohort, particularly in people with type 2 diabetes, to support their potential clinical relevance. We did not measure C-peptide, which may have provided additional insight into the insulinotropic effects of quinine. We also did not measure plasma concentrations of GLP-1 and peptide YY, known to modulate gastric emptying. Nevertheless, the absence of an effect of quinine on gastric emptying suggests these hormones played a limited role, if any. Plasma quinine concentrations were not measured; thus, it cannot be ascertained whether the observed effects of quinine reflect direct actions of circulating quinine on smooth muscle or pancreatic beta cells, as reported in malaria [5], rather than gut-mediated mechanisms. Quinine was administered intragastrically – in future studies, approaches more suitable for free-living settings, including encapsulated or controlled-release formulations, warrant evaluation.

In conclusion, in individuals without diabetes, intragastric quinine lowers plasma glucose, particularly postprandially, apparently as a result of insulin stimulation, without affecting either plasma glucagon or gastric emptying. Studies in individuals with T2D are warranted to explore the potential postprandial plasma glucose-lowering effects of quinine following a mixed solid-liquid meal, given that plasma glucose levels are predictably higher in this group. If such approaches prove successful, they may facilitate the development of novel, low-cost and safe therapeutic strategies for the management of T2D.

Acknowledgements

We thank our biostatistician, Dr Kylie Lange, Centre of Research Excellence in Translating Nutritional Science to Good Health, Adelaide University, for statistical support.

Declaration of generative AI use

The authors declare that no generative AI or AI-assisted technologies were used in the writing of this manuscript.

Abbreviations

GI

Gastrointestinal

GLP-1

Glucagon-like peptide-1

QHCl

Quinine hydrochloride

T2D

Type 2 diabetes

VAS

Visual analogue scale

Authors’ contributions

The authors’ responsibilities were as follows: PGH collected, analysed and interpreted the data, and wrote the manuscript; MM performed studies and collected data; VB contributed to the study concept and design; PCEF performed data collection; BDR analysed the insulin and glucagon data; JA-S contributed to data analysis and interpretation; SH analysed the gastric emptying data; KLJ contributed to study design, data analysis and interpretation; MH contributed to data interpretation and revised the manuscript; CFB contributed to the study concept and design, data analysis and interpretation, revised the manuscript and had primary responsibility for the project. All authors reviewed the manuscript and approved the final version of the manuscript.

Funding

Open Access funding enabled and organized by CAUL and its Member Institutions. PGH, MM, VB and JA-S by University of Adelaide Research Scholarships (PGH, 2024–2028; MM, 2022–2026; VB, 2017–2020; JA-S, 2021–2025), and CFB by a National Health and Medical Research Council of Australia (NHMRC) Senior Research Fellowship (Grant 1103020, 2016–2023).

Data availability

The data described in the manuscript may be made available upon request from the corresponding author. The data are not publicly available due to privacy reasons.

Declarations

Ethics approval and consent to participate

The study was approved by the Human Research Ethics Committee of the Central Adelaide Local Health Network (2021/HRE00253) and conducted in accordance with the Declaration of Helsinki and the NHMRC Statement on Ethical Conduct in Human Research. The trial was registered with the Australian and New Zealand Clinical Trials Registry (https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=383933&isReview=true registration no. ACTRN12622000735752, date of registration: May 23, 2022).

Competing interests

The authors declare no competing interests.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Parivash Ghorbaninejad and Maedeh Moradi are equal first authors.

References

  • 1.Kim KS, Egan JM, Jang HJ (2014) Denatonium induces secretion of glucagon-like peptide-1 through activation of bitter taste receptor pathways. Diabetologia 57(10):2117–2125. 10.1007/s00125-014-3326-5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.Xie C, Wang X, Young RL, Horowitz M, Rayner CK, Wu T (2018) Role of intestinal bitter sensing in enteroendocrine hormone secretion and metabolic control. Front Endocrinol (Lausanne) 9:576. 10.3389/fendo.2018.00576 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Rezaie P, Bitarafan V, Horowitz M, Feinle-Bisset C (2021) Effects of bitter substances on GI function, energy intake and glycaemia-do preclinical findings translate to outcomes in humans? Nutrients 13(4):1317. 10.3390/nu13041317 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Henquin JC (1982) Quinine and the stimulus-secretion coupling in pancreatic beta-cells: glucose-like effects on potassium permeability and insulin release. Endocrinology 110(4):1325–1332. 10.1210/endo-110-4-1325 [DOI] [PubMed] [Google Scholar]
  • 5.Okitolonda W, Delacollette C, Malengreau M, Henquin JC (1987) High incidence of hypoglycaemia in African patients treated with intravenous quinine for severe malaria. Br Med J (Clin Res Ed) 295(6600):716–718. 10.1136/bmj.295.6600.716 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Bitarafan V, Anjom-Shoae J, Rezaie P, Fitzgerald PCE, Lange K, Horowitz M, Feinle-Bisset C (2025) Dose-related effects of intraduodenal quinine on plasma glucose, glucoregulatory hormones and gastric emptying of a nutrient drink, and energy intake, in men with type 2 diabetes: a double-blind, randomised, crossover study. Diabetologia 68(4):727–738. 10.1007/s00125-024-06344-9 [DOI] [PubMed] [Google Scholar]
  • 7.Bitarafan V, Fitzgerald PCE, Little TJ, Meyerhof W, Jones KL, Wu T, Horowitz M, Feinle-Bisset C (2020) Intragastric administration of the bitter tastant quinine lowers the glycemic response to a nutrient drink without slowing gastric emptying in healthy men. Am J Physiol Regul Integr Comp Physiol 318(2):R263–273. 10.1152/ajpregu.00294.2019 [DOI] [PubMed] [Google Scholar]
  • 8.Andreozzi P, Sarnelli G, Pesce M, Zito FP, Alessandro AD, Verlezza V, Palumbo I, Turco F, Esposito K, Cuomo R (2015) The bitter taste receptor agonist quinine reduces calorie intake and increases the postprandial release of cholecystokinin in healthy subjects. J Neurogastroenterol Motil 21(4):511–519. 10.5056/jnm15028 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Rose BD, Bitarafan V, Rezaie P, Fitzgerald PCE, Horowitz M, Feinle-Bisset C (2021) Comparative effects of intragastric and intraduodenal administration of quinine on the plasma glucose response to a mixed-nutrient drink in healthy men: relations with glucoregulatory hormones and gastric emptying. J Nutr 151(6):1453–1461. 10.1093/jn/nxab020 [DOI] [PubMed] [Google Scholar]
  • 10.Phillips LK, Rayner CK, Jones KL, Horowitz M (2014) Measurement of gastric emptying in diabetes. J Diabetes Complications 28(6):894–903. 10.1016/j.jdiacomp.2014.06.005 [DOI] [PubMed] [Google Scholar]
  • 11.Collins PJ, Houghton LA, Read NW, Horowitz M, Chatterton BE, Heddle R, Dent J (1991) Role of the proximal and distal stomach in mixed solid and liquid meal emptying. Gut 32(6):615–619. 10.1136/gut.32.6.615 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Wang Y, Chen JDZ, Nojkov B (2023) Diagnostic methods for evaluation of gastric motility-a mini review. Diagnostics (Basel) 13(4):803. 10.3390/diagnostics13040803 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 13.Australian Radiation Protection and Nuclear Safety Agency (2008) Radiation protection in nuclear medicine. Radiation Prot Ser No. 14.2. ARPANSA, Yallambie (Vic)
  • 14.Stunkard AJ, Messick S (1985) The three-factor eating questionnaire to measure dietary restraint, disinhibition and hunger. J Psychosom Res 29(1):71–83. 10.1016/0022-3999(85)90010-8 [DOI] [PubMed] [Google Scholar]
  • 15.Brennan IM, Feltrin KL, Nair NS, Hausken T, Little TJ, Gentilcore D, Wishart JM, Jones KL, Horowitz M, Feinle-Bisset C (2009) Effects of the phases of the menstrual cycle on gastric emptying, glycemia, plasma GLP-1 and insulin, and energy intake in healthy lean women. Am J Physiol Gastrointest Liver Physiol 297(3):G602–610. 10.1152/ajpgi.00051.2009 [DOI] [PubMed] [Google Scholar]
  • 16.Umapathysivam MM, Lee MY, Jones KL, Annink CE, Cousins CE, Trahair LG, Rayner CK, Chapman MJ, Nauck MA, Horowitz M, Deane AM (2014) Comparative effects of prolonged and intermittent stimulation of the glucagon-like peptide 1 receptor on gastric emptying and glycemia. Diabetes 63(2):785–790. 10.2337/db13-0893 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Jones KL, Huynh LQ, Hatzinikolas S, Rigda RS, Phillips LK, Pham HT, Marathe CS, Wu T, Malbert CH, Stevens JE, Lange K, Rayner CK, Horowitz M (2020) Exenatide once weekly slows gastric emptying of solids and liquids in healthy, overweight people at steady-state concentrations. Diabetes Obes Metab 22(5):788–797. 10.1111/dom.13956 [DOI] [PubMed] [Google Scholar]
  • 18.Pham H, Holen IS, Phillips LK, Hatzinikolas S, Huynh LQ, Wu T, Hausken T, Rayner CK, Horowitz M, Jones KL (2019) The effects of a whey protein and guar gum-containing preload on gastric emptying, glycaemia, small intestinal absorption and blood pressure in healthy older subjects. Nutrients 11(11):2666. 10.3390/nu11112666 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Collins PJ, Horowitz M, Cook DJ, Harding PE, Shearman DJ (1983) Gastric emptying in normal subjects–a reproducible technique using a single scintillation camera and computer system. Gut 24(12):1117–1125. 10.1136/gut.24.12.1117 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 20.Parker BA, Sturm K, MacIntosh CG, Feinle C, Horowitz M, Chapman IM (2004) Relation between food intake and visual analogue scale ratings of appetite and other sensations in healthy older and young subjects. Eur J Clin Nutr 58(2):212–218. 10.1038/sj.ejcn.1601768 [DOI] [PubMed] [Google Scholar]
  • 21.Sajjad M, Ghorbaninejad P, Bitarafan V, Anjom-Shoae J, Rose BD, Fitzgerald PC, Horowitz M, Feinle-Bisset C (2026) Effects of combined intragastric administration of quinine with L-leucine or L-isoleucine on the glycemic response to, and gastric emptying of, a mixed-nutrient drink in healthy males. J Nutr 156(2):101259. 10.1016/j.tjnut.2025.101259 [DOI] [PubMed] [Google Scholar]
  • 22.Phillips DI, Clark PM, Hales CN, Osmond C (1994) Understanding oral glucose tolerance: comparison of glucose or insulin measurements during the oral glucose tolerance test with specific measurements of insulin resistance and insulin secretion. Diabet Med 11(3):286–292. 10.1111/j.1464-5491.1994.tb00273.x [DOI] [PubMed] [Google Scholar]
  • 23.Bland JM, Altman DG (1995) Calculating correlation coefficients with repeated observations: Part 1–Correlation within subjects. BMJ 310(6977):446. 10.1136/bmj.310.6977.446 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 24.Rezaie P, Bitarafan V, Rose BD, Lange K, Mohammadpour Z, Rehfeld JF, Horowitz M, Feinle-Bisset C (2023) Effects of quinine on the glycaemic response to, and gastric emptying of, a mixed-nutrient drink in females and males. Nutrients 15(16):3584. 10.3390/nu15163584 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Marathe CS, Rayner CK, Jones KL, Horowitz M (2013) Relationships between gastric emptying, postprandial glycemia, and incretin hormones. Diabetes Care 36(5):1396–1405. 10.2337/dc12-1609 [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Nauck MA, Kleine N, Orskov C, Holst JJ, Willms B, Creutzfeldt W (1993) Normalization of fasting hyperglycaemia by exogenous glucagon-like peptide 1 (7–36 amide) in type 2 (non-insulin-dependent) diabetic patients. Diabetologia 36(8):741–744. 10.1007/bf00401145 [DOI] [PubMed] [Google Scholar]
  • 27.Phillips LK, Deane AM, Jones KL, Rayner CK, Horowitz M (2015) Gastric emptying and glycaemia in health and diabetes mellitus. Nat Rev Endocrinol 11(2):112–128. 10.1038/nrendo.2014.202 [DOI] [PubMed] [Google Scholar]
  • 28.Santos FA, Rao VS (1999) Quinine-induced inhibition of gastrointestinal transit in mice: possible involvement of endogenous opioids. Eur J Pharmacol 364(2–3):193–197. 10.1016/s0014-2999(98)00842-5 [DOI] [PubMed] [Google Scholar]
  • 29.Datz FL, Christian PE, Moore J (1987) Gender-related differences in gastric emptying. J Nucl Med 28(7):1204–1207 [PubMed] [Google Scholar]
  • 30.Xiang C, Sun Y, Luo Y, Xie C, Huang W, Jones KL, Horowitz M, Sun Z, Rayner CK, Ma J, Wu T (2024) Gastric emptying is slower in women than men with type 2 diabetes and impacts on postprandial glycaemia. Diabetes Obes Metab 26(8):3119–3127. 10.1111/dom.15635 [DOI] [PubMed] [Google Scholar]
  • 31.Soenen S, Rayner CK, Horowitz M, Jones KL (2015) Gastric emptying in the elderly. Clin Geriatr Med 31(3):339–353. 10.1016/j.cger.2015.04.003 [DOI] [PubMed] [Google Scholar]
  • 32.Cowart BJ, Yokomukai Y, Beauchamp GK (1994) Bitter taste in aging: compound-specific decline in sensitivity. Physiol Behav 56(6):1237–1241. 10.1016/0031-9384(94)90371-9 [DOI] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Data Availability Statement

The data described in the manuscript may be made available upon request from the corresponding author. The data are not publicly available due to privacy reasons.


Articles from European Journal of Nutrition are provided here courtesy of Springer

RESOURCES