Abstract

Background:

Extended high-frequency (EHF; 9–20 kHz) hearing loss can emerge despite audiometric thresholds within normal limits (i.e., ≤20 dB HL for 0.25–8 kHz) and may signal early auditory decline. Auditory brainstem responses (ABRs) are candidate objective markers, but standard broadband click ABRs may be insensitive to subtle, frequency-specific neural changes.

Purpose:

We tested whether a 4-kHz centered chirp-evoked ABR differentiates young adults by EHF sensitivity better than traditional click-evoked ABR.

Research Design:

This was a cross-sectional, between-groups comparison of ABR metrics (Wave I, Wave V, and Wave I/V amplitude ratio) elicited by clicks versus a 4-kHz narrowband chirp.

Study Sample:

The study included 30 young adults (27 females, 3 males; 18–28 years of age; mean age = 20.06 years, standard deviation = 2.16). Participants were grouped by EHF pure-tone average (10, 12.5, 16, and 20 kHz): Better EHF (≤0 dB HL; n = 18) and Worse EHF (>0 dB HL; n = 12). Standard audiometric thresholds (0.25–8 kHz) were within normal limits in both groups; groups differed at 10–20 kHz.

Data Collection and Analysis:

Right-ear stimulation was achieved via insert earphones with the following characteristics: click: 100-µs pulse (10 Hz–10 kHz); chirp: 2,000 µs upward iChirp centered at 4 kHz (−6 dB ≈ 3.97–5.03 kHz); 1,600 alternating-polarity sweeps/stimulus at 70 dB nHL; 11.1/s; Cz-to-mastoid montage; 100- to 3000-Hz bandpass. Two blinded raters marked Wave I (1–2 ms) and Wave V (5–7 ms); amplitudes were quantified peak-to-trough. Group comparisons used Welch’s t tests with within-family Bonferroni correction.

Results:

Click-evoked ABRs did not differ between groups (Wave I: Better = 0.191 µV, Worse = 0.196 µV, p = 0.894; Wave V: Better = 0.369 µV, Worse = 0.400 µV, p = 0.479; I/V ratio: p = 0.847). Chirp-evoked ABRs showed (1) a trend toward smaller Wave I in the Worse EHF group (Better = 0.386 µV, Worse = 0.307 µV, p = 0.150); (2) significantly larger Wave V in the Worse group (Better = 0.319 µV, Worse = 0.425 µV, Bonferroni-corrected p = 0.033); and (3) a significantly lower Wave I/V ratio in the Worse group (Better = 1.40, Worse = 0.751; Bonferroni-corrected p = 0.0214).

Conclusions:

In this preliminary sample, 4-kHz chirp-evoked ABRs, but not clicks, differentiated young adults by EHF sensitivity, suggesting high-frequency-specific ABR paradigms can reveal subtle neural differences associated with EHF loss.

Clinical Relevance Statement:

Chirp-based ABR measures that target ∼4 kHz may complement EHF audiometry by capturing subtle neural differences before overt perceptual deficits emerge. Such objective markers could help clinicians identify at-risk listeners earlier and refine monitoring protocols in noise-exposed or otherwise vulnerable populations.

Keywords: auditory brainstem response, extended high frequency, subclinical hearing loss

INTRODUCTION

Extended high-frequency (EHF; 9–20 kHz) hearing loss can occur even among individuals with audiograms within clinical reference limits (0.25–8 kHz) and is considered an early indicator of future auditory decline (Mehrparvar et al., 2011). Despite its prevalence, affecting 19–56 percent of young, healthy individuals (Mishra et al., 2022a; Motlagh Zadeh et al., 2019), EHF hearing loss is often missed because it relies on behavioral EHF audiometry, which cannot be completed in all patients (e.g., young children) and is more susceptible to variability from acoustic factors such as ear-canal resonances, both in the high-frequency and the EHF range (more for TDH headphones than well-placed inserts) (Bharadwaj et al., 2019; Lapsley Miller et al., 2018). Objective electrophysiological markers may therefore provide complementary information, particularly for patients who cannot complete behavioral testing. To objectively assess early auditory processes, auditory brainstem responses (ABRs) provide a useful measure. ABR-based testing is clinically relevant given associations between EHF loss and poorer speech-in-noise perception (Badri et al., 2011; Shaw et al., 1996) as well as increased self-reported listening difficulties (Braza et al., 2022; Monson et al., 2019; Polspoel et al., 2022). In this pilot study, we tested whether a 4-kHz chirp-based ABR protocol could reveal neural correlates of EHF loss.

ABRs provide an objective index of subcortical auditory function. Prior work has examined Wave I amplitude and the Wave I/V amplitude ratio as indices of suprathreshold neural status (Bramhall et al., 2019; Gu et al., 2012; Schaette & McAlpine, 2011), yet links between EHF status and click-evoked ABRs remain mixed. Some studies have reported reduced Wave I amplitudes with elevated EHF thresholds (Bharadwaj et al., 2019; Grose et al., 2017; Patro et al., 2024), whereas others found no such relationship (Balan et al., 2025; Gu et al., 2012; Liberman et al., 2016). These discrepancies could potentially stem from the small and variable nature of ABR Wave I. Intersubject variability in Wave I amplitude and latency has been linked to factors such as head size, skull thickness, and sex (Mehraei et al., 2016; Stamper & Johnson, 2015), and ambient cortical and muscular noise further degrades the already low signal-to-noise ratio, leading to inconsistent measurements even within the same person (Stamper & Johnson, 2015). The inherently small and variable amplitude of Wave I (Beattie, 1988; Jiang et al., 1993; Lauter & Loomis, 1988), together with the broad excitation and dispersion effects of traditional broadband click stimuli (Don et al., 1994; Nuttall et al., 2015), further limits its reliability. As discussed in Furlong & Maggu (2025), these methodological constraints highlight the need for stimuli that enhance Wave I detectability and reduce variability.

Among stimulus-based approaches, narrowband high-frequency tone bursts, particularly those centered near 4 kHz, have shown moderately better consistency in eliciting Wave I compared with broadband clicks. These tone bursts have also revealed significant Wave I amplitude differences between tinnitus or noise-exposed listeners and matched controls (Bramhall et al., 2017). This line of work was later extended using high-pass clicks restricted to 3–8 kHz, which produced a Wave I larger than Wave V and yielded a Wave I/V amplitude ratio greater than 1 (Bharadwaj et al., 2019). However, although these stimulus-based efforts have shown promise in enhancing Wave I amplitude, they have not sufficiently reduced inter- and intrasubject variability, much of which reflects the influence of extraneous, nonneural factors on the ABR. Recent work using 4-kHz chirp (2 ms; energy approximately 3–7 kHz) (Furlong & Maggu, 2025) has shown significantly larger and more reliable Wave I amplitudes compared with the traditional broadband click by targeting basal, high-frequency cochlear regions responsible for Wave I generation and compensates for cochlear dispersion to improve neural synchrony (Bal et al., 2022; Elberling & Don, 2008; Elberling et al., 2010).

EHF deficits often co-occur with functional compromise of adjacent cochlear regions near 3–6 kHz, frequencies that are among the first affected by age- or noise-related hearing damage (Hunter et al., 2020; Mishra et al., 2022b, 2024). Chirp stimuli are increasingly adopted in clinical ABR testing to improve the detectability of early auditory-evoked responses, particularly Wave I (Adel et al., 2021; Cebulla & Stürzebecher, 2013; Cebulla et al., 2014) and Wave V for threshold estimation (Elberling & Don, 2008). Building on prior work showing that the 4-kHz chirp enhances Wave I amplitude and reliability relative to the broadband click (Furlong & Maggu, 2025), we asked whether 4-kHz chirp-evoked ABRs would differentiate young adults grouped by EHF sensitivity more effectively than click-evoked ABRs. We hypothesized that participants with poorer EHF thresholds would show smaller Wave I, larger Wave V, and lower Wave I/V ratios, and that these effects would be more evident with the 4-kHz chirp than with the click stimulus. As a brief report, this study presents preliminary data intended to motivate larger, fully powered investigations and inform future clinical applications.

METHODS

Participants

Thirty young adults (27 female, 3 male; age range 18–28 years, mean [M] = 20.06 years, standard deviation = 2.16) participated in the study. They were recruited through the University of Connecticut listservs, institutional newsletters, and flyers and were compensated at $15/hour for their time. Participants had no history of otologic, audiological, speech, language, or neurological disorder. The Institutional Review Board approved the study at the University of Connecticut (no. H23-0786). Testing was conducted by the second author and trained student research assistants under supervision from the first and second authors.

Hearing Testing

All participants were tested for their air-conduction hearing thresholds using a GSI-Audiostar audiometer (Grason-Stadler, Eden Prairie, MN) using pure tones routed through RadioEar DD450 HF circum-aural headphones (Otometrics, Denmark). For all participants, air-conduction thresholds were obtained for standard audiometric frequencies (i.e., 0.25–8 kHz) and EHF (10–20 kHz) (Figure 1A). Standard-frequency thresholds (0.25–8 kHz) were considered within clinical reference limits if ≤20 dB HL at all frequencies (with the exception of one participant who presented with a 25 dB HL threshold at a single frequency). If no response was obtained at the audiometer’s maximum output level, that frequency was treated as missing and excluded from the EHF pure-tone average (PTA) calculation. Across all participants, only two no-response values were observed, both occurring at 20 kHz. No participant had multiple no-response values that would have disproportionately affected their EHF PTA or their subsequent classification.

Figure 1.

Figure 1.

Audiometric profiles of Better versus Worse extended high-frequency (EHF) groups. (A) Individual (light lines) and group mean (bold lines ± 1 standard error of the mean) air-conduction thresholds from 0.25 to 20 kHz show comparable hearing through 10 kHz but elevated thresholds in the Worse EHF group at 12.5–20 kHz. (B) Group comparison of the EHF pure-tone average (PTA; 10–20 kHz) illustrates a clear separation between the Better and Worse EHF groups (***p < 0.001), confirming successful group stratification.

Using median split on the EHF PTA that is average of thresholds at 10, 12.5, 16, and 20 kHz, participants were classified as “Better EHF” (0 dB HL and below; n = 18; 16 female, 2 male) and “Worse EHF” (above 0 dB HL; n = 12; 11 female, 1 male) (Figure 1B). The two groups were statistically distinct on their EHF PTA values; the Worse EHF group (10.9 ± 7.7 dB HL) had significantly higher thresholds than the Better EHF group: –3.2 ± 3.4 dB HL, t(13.9) = –6.00, p < 0.001, 95 percent confidence interval (CI) = [–19.16, –9.06], Cohen’s d = 2.57. In comparison, the two groups did not differ on frequencies ranging from 0.25–8 kHz: t(22.26) = –0.81, p = 0.42, 95 percent CI = [–4.43, 1.93], Cohen’s d = 0.31. This classification supported the design of the present proof-of-concept, exploratory study, which aimed to evaluate the potential sensitivity of chirp-evoked ABRs to EHF-related auditory differences.

Stimuli and Apparatus

Data were collected in separate blocks for each stimulus type, either click or chirp. Ipsilateral right-ear stimuli were presented through ultrashielded 300 Ω insert phones (Intelligent Hearing Systems, Miami, FL). The click stimulus was a 100-µs broadband pulse spanning 10 Hz–10 kHz (Figure 2A). To probe frequency-specific neural responses from the basal cochlea, we employed a 4-kHz narrowband iChirp stimulus generated using the de Boer cochlear model (IHS SmartEP). The iChirp4000 stimulus was a 2,000-µs linear upward sweep designed to maximize synchrony in the 4-kHz region, with –6 dB bandwidth limits spanning approximately 3.97–5.03 kHz (Figure 2B). Stimulus order was counterbalanced across subjects. Each stimulus block consisted of 1,600 sweeps presented in alternating polarity at 70 dB nHL, with a repetition rate of 11.1/second. Responses were recorded at a 40,000-Hz sampling rate using a Cz (+)—right mastoid (–)—lower forehead (ground) montage, amplified 100,000×, and bandpass-filtered from 100–3000 Hz using the Duet Intelligent Hearing System’s SmartEP platform.

Figure 2.

Figure 2.

Comparison of click and iChirp 4-kHz stimulus on (A) waveform and (B) spectrum. The click is a 100-µs broadband pulse spanning 10 Hz to 10 kHz. The iChirp 4k was a 2,000-µs narrowband chirp centered at around 4 kHz. a.u. = arbitrary units.

Procedure

Participants sat comfortably in a recliner in an acoustically and electrically shielded booth and were encouraged to relax to minimize muscle artifacts. Each stimulus was presented in two runs of 1,600 rejection-free sweeps. Sweeps exceeding ± 31 µV were automatically rejected, and if more than 10 percent were rejected the run was repeated.

Peak Identification

Two experienced raters who were blinded to stimulus condition and group membership independently marked Wave I (1–2 ms) and Wave V (5–7 ms) peak-to-trough. Discrepancies were resolved through discussion with a third rater. A fourth reviewer then verified all amplitude measurements before transferring them to the dataset. Amplitude was quantified using the peak-to-trough method (Balan et al., 2025; Le Prell, 2019).

Between-group comparisons were conducted using Welch’s t tests, which do not assume equal variances or sample sizes. Effect sizes (Cohen’s d) and 95 percent CIs were reported for all primary outcomes. Where multiple related comparisons were made, p values were adjusted using the Bonferroni correction.

RESULTS

Grand-average waveforms (Figure 3A and 3B) are provided to illustrate morphology. They are not the basis for statistical inference. All statistical tests used subject-level peak-to-trough amplitudes, which are less affected by intersubject latency variability that can smear peaks in grand averages.

Figure 3.

Figure 3.

Comparison of auditory brainstem responses (ABRs) between Better and Worse extended high-frequency (EHF) groups. (A and B) Grand-average ABR waveforms for click and 4-kHz chirp stimuli, respectively. (C) Wave I amplitude. (D) Wave V amplitude. (E) Wave I/V amplitude ratio. Error bars in C–E represent ± 1 standard error of the mean; shaded areas in A and B show ± 95 % confidence intervals; *p < 0.05.

For Wave I amplitude (Figure 3C), there was a nonsignificant trend for the chirp-evoked responses: the Better group (M = 0.386 µV, standard error of the mean [SEM] = 0.032) showed higher amplitude than the Worse group (M = 0.307 µV, SEM = 0.043), t(22.4) = 1.49, p = 0.150, Cohen’s d = 0.56, 95 percent CI = –0.19, 1.29. No difference was observed for click-evoked responses (Better = 0.191 µV, SEM = 0.025, Worse = 0.196 µV, SEM = 0.024), t(27.1) = –0.14, p = 0.894, Cohen’s d = 0.05. Within each group, chirp-evoked Wave I amplitude tended to be larger than click-evoked Wave I amplitude.

For Wave V amplitude (Figure 3D), chirp-evoked amplitudes were significantly larger in the Worse group (M = 0.425 µV, SEM = 0.024) than in the Better group (M = 0.319 µV, SEM = 0.034), t(27.5) = –2.55, p = 0.0165 (Bonferroni‐corrected p = 0.033), Cohen’s d = 0.86, 95 percent CI = 0.07, 1.60. Click-evoked amplitudes did not differ (Worse = 0.400 µV, SEM = 0.030; Better = 0.369 µV, SEM = 0.032), t(27.5) = –0.72, p = 0.479, Cohen’s d = 0.25. Overall, for the Worse EHF group, Wave V amplitudes did not differ across the stimuli, but for the Better EHF group Wave V amplitude was a bit reduced for the chirp stimuli compared to the click stimuli.

For the I/V amplitude ratio (Figure 3E), the chirp-evoked ratio was higher in the Better group (M = 1.40, SEM = 0.205) than in the Worse group (M = 0.751, SEM = 0.115), t(25.5) = 2.75, p = 0.0107 (Bonferroni‐corrected p = 0.0214), Cohen’s d = 0.90, 95 percent CI = 0.16, 1.13. The click-evoked ratio showed no group difference (Better = 0.590, SEM = 0.101; Worse = 0.560, SEM = 0.116), t(24.7) = 0.20, p = 0.847, Cohen’s d = 0.07. Overall, for the Worse EHF group, I/V amplitude ratio did not differ across the stimuli, but for the Better EHF group I/V amplitude ratio was enhanced for the chirp stimuli compared to the click stimuli.

DISCUSSION

This study compared 4-kHz chirp-evoked ABRs and click-evoked ABRs in young adults with relatively better versus worse EHF hearing sensitivity. We observed no significant effects of EHF sensitivity on Wave I or V amplitudes of click-evoked ABRs. In contrast, the 4-kHz chirp differentiated groups: listeners with poorer EHF thresholds showed a trend toward smaller Wave I, significantly larger Wave V, and significantly lower Wave I/V amplitude ratios. These preliminary findings suggest that frequency-specific, 4-kHz chirp-evoked ABRs may be sensitive to subtle differences associated with EHF hearing status that are not evident with clicks.

These results align with previous findings indicating that stimuli above 3 kHz can yield enhanced Wave I/V amplitude ratios as compared to traditional broadband click (Bharadwaj et al., 2019), potentially reflecting compensatory central gain at higher auditory processing stages in response to peripheral neural compromise (Schaette & McAlpine, 2011). In the current study, listeners with poorer EHF thresholds showed larger Wave V amplitudes and reduced I/V ratios, consistent with this compensatory mechanism. Evidence from our recent 4-kHz chirp study in typical listeners (Furlong & Maggu, 2025) showed enhanced Wave I amplitudes and stable Wave V responses compared with clicks, a pattern suggesting improved peripheral synchrony without additional central gain in those with typical hearing abilities. Together, these findings indicate that whereas the 4-kHz chirp stimuli strengthen peripheral synchrony under typical conditions, they also reveal central gain compensation when peripheral input is weakened, underscoring the potential of 4-kHz chirp-evoked ABRs to capture the EHF-related dysfunction.

The current study’s click ABR results are consistent with earlier research (Balan et al., 2025; Liberman et al., 2016), which also reported no significant relationship between click ABR and EHF thresholds and likely reflect the limited sensitivity of broadband clicks, which broadly excite the cochlea and are affected by dispersion. By design, the 4-kHz chirp stimulus used in the present study provides a targeted alternative that enhances neural synchrony, thereby increasing the sensitivity of ABR measures to early-stage auditory neural differences. The observed enhancements in Wave I and V amplitudes with chirp stimuli as compared to click stimuli are supported by prior research (Cebulla & Stürzebecher, 2013; Cebulla et al., 2014; Elberling & Don, 2008; Morimoto et al., 2019). However, our click ABR findings contrast with some previous studies (e.g., Grose et al., 2017; Patro et al., 2024) that showed differences in ABR amplitudes between groups with differing degree of EHF loss. These discrepancies could result from methodological differences, such as variations in EHF frequency ranges tested (current study: 10, 12.5, 16, and 20 kHz versus 11.2 and 16 kHz in Grose et al., 2017 and 10–16 kHz in Patro et al., 2024), differences in electrode montages (scalp-recorded ABR in the current study versus tiptrode-based montage in Grose et al., 2017), or demographic differences (young adults in this study versus a broader age range including young to middle-aged adults in Patro et al. [2024]).

From a clinical perspective, a 4-kHz chirp-based ABR paradigm could complement EHF audiometry by providing an objective probe when behavioral testing is not feasible or when clinicians seek converging evidence of early change. Further, comparing I/V ratios within the same listener across stimuli (ΔI/V = Chirp I/V – Click I/V) may enhance sensitivity to subtle basal-cochlear dysfunction associated with poorer EHF thresholds. In our data, the ΔI/V pattern was larger in the better-EHF group and comparatively attenuated in the worse-EHF group, suggesting that a simple two-stimulus protocol could aid early identification when standard audiometry appears normal. Prospective work should establish normative ΔI/V ranges and diagnostic utility. These preliminary data motivate further work to determine the clinical utility of such frequency-targeted ABR measures.

Limitations and Future Directions

The sample was modest (Better EHF: n = 18; Worse EHF: n = 12), which limits power and generalizability and necessitated multiple comparisons; results should be interpreted cautiously. We applied within-family corrections, but future studies should incorporate larger, fully powered cohorts. The sample was predominantly young with typical hearing at standard frequencies, and we did not model potential covariates such as sex or individual noise-exposure history; future work should allow covariate adjustment. Although chirp stimuli enhance synchrony and improve Wave I detectability, frequency selectivity may be limited by spread of excitation and interactions with adjacent cochlear regions. Finally, recordings were obtained from the right ear at a fixed level; evaluating level effects, ear laterality, and complementary measures will clarify the robustness and scope of chirp ABR markers across populations.

Acknowledgments

The authors thank Emma Kindl and Mikayla Mansfield for assistance with subject recruitment, data collection, and data logistics. The authors used AI-assisted editing for language clarity; the authors reviewed and are accountable for all content.

Abbreviations:

ABR

auditory brainstem response

CI

confidence interval

EHF

extended high frequency

M

mean

PTA

pure-tone average

SEM

standard error of the mean

Footnotes

Any mention of a product, service, or procedure in the Journal of the American Academy of Audiology does not constitute an endorsement of the product, service, or procedure by the American Academy of Audiology.

REFERENCES

  1. Adel, G., El-Hefnawy, H., & El-Kholy, W. (2021). Evaluation of frequency-specific chirp-evoked compound action potentials in Guinea pigs. International Journal of Pediatric Otorhinolaryngology, 149, 110843. [Google Scholar]
  2. Badri, R., Siegel, J. H., & Wright, B. A. (2011). Auditory filter shapes and high-frequency hearing in adults who have impaired speech in noise performance despite clinically normal audiograms. The Journal of the Acoustical Society of America, 129(2), 852–863. 10.1121/1.3523476. [DOI] [PMC free article] [PubMed] [Google Scholar]
  3. Bal, N., Toker, Ö. G., Hüsam, H., Özdemir, S., & Lien, B. D. (2022). Optimizing auditory brainstem response test with narrow band level-specific CE-chirps. Annals of Otology and Neurotology, 5, 50–54. [Google Scholar]
  4. Balan, J. R., Mishra, S. K., & Rodrigo, H. (2025). Extended high-frequency hearing and suprathreshold neural synchrony in the auditory brainstem. The Journal of the Acoustical Society of America, 157(3), 1577–1586. 10.1121/10.0036054. [DOI] [PubMed] [Google Scholar]
  5. Beattie, R. C. (1988). Interaction of click polarity, stimulus level, and repetition rate on the auditory brainstem response. Scandinavian Audiology. 17(2), 99–109. 10.3109/01050398809070698. [DOI] [PubMed] [Google Scholar]
  6. Bharadwaj, H. M., Mai, A. R., Simpson, J. M., Choi, I., Heinz, M. G., & Shinn-Cunningham, B. G. (2019). Non-invasive assays of cochlear synaptopathy–candidates and considerations. Neuroscience, 407, 53–66. 10.1016/j.neuroscience.2019.02.031. [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Bramhall, N. F., Beach, E. F., & Epp, B. (2019). Auditory brainstem response wave I amplitude: a biomarker of cochlear synaptopathy. Ear and Hearing, 40, 545–554. [Google Scholar]
  8. Bramhall, N. F., Konrad-Martin, D., McMillan, G. P., & Griest, S. E. (2017). Auditory brainstem response altered in humans with noise exposure despite normal outer hair cell function. Ear and Hearing, 38(1), e1–e12. 10.1097/AUD.0000000000000370. [DOI] [PMC free article] [PubMed] [Google Scholar]
  9. Braza, M. D., Corbin, N. E., Buss, E., & Monson, B. B. (2022). Effect of masker head orientation, listener age, and extended high-frequency sensitivity on speech recognition in spatially separated speech. Ear and Hearing, 43(1), 90–100. 10.1097/AUD.0000000000001081. [DOI] [PMC free article] [PubMed] [Google Scholar]
  10. Cebulla, M., Lurz, H., & Shehata-Dieler, W. (2014). Evaluation of waveform, latency and amplitude values of chirp ABR in newborns. International Journal of Pediatric Otorhinolaryngology, 78(4), 631–636. 10.1016/j.ijporl.2014.01.020. [DOI] [PubMed] [Google Scholar]
  11. Cebulla, M., & Stürzebecher, E. (2013). Detectability of newborn chirp-evoked ABR in the frequency domain at different stimulus rates. International Journal of Audiology, 52(10), 698–705. 10.3109/14992027.2013.804634. [DOI] [PubMed] [Google Scholar]
  12. Don, M., Ponton, C. W., Eggermont, J. J., & Masuda, A. (1994). Auditory brainstem response (ABR) peak amplitude variability reflects individual differences in cochlear response times. The Journal of the Acoustical Society of America, 96(6), 3476–3491. 10.1121/1.410608. [DOI] [PubMed] [Google Scholar]
  13. Elberling, C., Callø, J., & Don, M. (2010). Evaluating auditory brainstem responses to different chirp stimuli at three levels of stimulation. The Journal of the Acoustical Society of America, 128(1), 215–223. 10.1121/1.3397640. [DOI] [PMC free article] [PubMed] [Google Scholar]
  14. Elberling, C., & Don, M. (2008). Auditory brainstem responses to a chirp stimulus designed from derived-band latencies in normal-hearing subjects. The Journal of the Acoustical Society of America, 124(5), 3022–3037. 10.1121/1.2990709. [DOI] [PMC free article] [PubMed] [Google Scholar]
  15. Furlong, C., & Maggu, A. R. (2025). ABR wave I is enhanced with 4 kHz chirp compared to traditional broadband click. Hearing Research, 468, 109467. 10.1016/j.heares.2025.109467. [DOI] [PubMed] [Google Scholar]
  16. Grose, J. H., Buss, E., & Hall, J. W. (2017). Loud music exposure and cochlear synaptopathy in young adults: isolated auditory brainstem response effects but no perceptual consequences. Trends in Hearing, 21, 2331216517737417. 10.1177/2331216517737417. [DOI] [PMC free article] [PubMed] [Google Scholar]
  17. Gu, J. W., Herrmann, B. S., Levine, R. A., & Melcher, J. R. (2012). Brainstem auditory evoked potentials suggest a role for the ventral cochlear nucleus in tinnitus. Journal of the Association for Research in Otolaryngology, 13(6), 819–833. 10.1007/s10162-012-0344-1. [DOI] [PMC free article] [PubMed] [Google Scholar]
  18. Hunter, L. L., Monson, B. B., Moore, D. R., Dhar, S., Wright, B. A., … Siegel, J. H. (2020). Extended high frequency hearing and speech perception implications in adults and children. Hearing Research, 397, 107922. 10.1016/j.heares.2020.107922. [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Jiang, Z. D., Li, Z., Wu, Y. Y., & Liu, X. Y. (1993). Brainstem auditory evoked responses from birth to adulthood: development of wave amplitude. Hearing Research, 68(1), 35–41. 10.1016/0378-5955(93)90062-6. [DOI] [PubMed] [Google Scholar]
  20. Lapsley Miller, J. A., Reed, C. M., Robinson, S. R., & Perez, Z. D. (2018). Pure-tone audiometry with forward pressure level calibration leads to clinically-relevant improvements in test–retest reliability. Ear and Hearing, 39(5), 946–957. 10.1097/AUD.0000000000000555. [DOI] [PubMed] [Google Scholar]
  21. Lauter, J. L., & Loomis, R. L. (1988). Individual differences in auditory electric responses: comparisons of between-subject and within-subject variability II. Amplitude of brainstem vertex-positive peaks. Scandinavian Audiology, 17(2), 87–92. 10.3109/01050398809070696. [DOI] [PubMed] [Google Scholar]
  22. Le Prell, C. G. (2019). Effects of noise exposure on auditory brainstem response and speech-in-noise tasks: a review of the literature. International Journal of Audiology, 58(Suppl. 1), S3–S32. 10.1080/14992027.2018.1534010. [DOI] [PubMed] [Google Scholar]
  23. Liberman, M. C., Epstein, M. J., Cleveland, S. S., Wang, H., & Maison, S. F. (2016). Toward a differential diagnosis of hidden hearing loss in humans. PloS One, 11(9), e0162726. 10.1371/journal.pone.0162726. [DOI] [PMC free article] [PubMed] [Google Scholar]
  24. Mehraei, G., Hickox, A. E., Bharadwaj, H. M., Goldberg, H., Verhulst, S., … Shinn-Cunningham, B. G. (2016). Auditory brainstem response latency in noise as a marker of cochlear synaptopathy. The Journal of Neuroscience, 36(13), 3755–3764. 10.1523/JNEUROSCI.4460-15.2016. [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Mehrparvar, A. H., Mirmohammadi, S. J., Ghoreyshi, A., Mollasadeghi, A., & Loukzadeh, Z. (2011). High-frequency audiometry: a means for early diagnosis of noise-induced hearing loss. Noise & Health, 13(55), 402–406. 10.4103/1463-1741.90295. [DOI] [PubMed] [Google Scholar]
  26. Mishra, S. K., Rodrigo, H., & Balan, J. R. (2024). Exploring the influence of extended high-frequency hearing on cochlear functioning at lower frequencies. Journal of Speech, Language, and Hearing Research, 67(7), 2473–2482. 10.1044/2024_JSLHR-23-00652. [DOI] [PubMed] [Google Scholar]
  27. Mishra, S. K., Saxena, U., & Rodrigo, H. (2022a). Extended high-frequency hearing impairment despite a normal audiogram: relation to early aging, speech-in-noise perception, cochlear function, and routine earphone use. Ear and Hearing, 43(3), 822–835. 10.1097/AUD.0000000000001140. [DOI] [PubMed] [Google Scholar]
  28. Mishra, S. K., Saxena, U., & Rodrigo, H. (2022b). Hearing impairment in the extended high frequencies in children despite clinically normal hearing. Ear and Hearing, 43(6), 1653–1660. 10.1097/AUD.0000000000001225. [DOI] [PubMed] [Google Scholar]
  29. Monson, B. B., Rock, J., Schulz, A., Hoffman, E., Buss, E. (2019). Ecological cocktail party listening reveals the utility of extended high-frequency hearing. Hearing Research. 381, 107773. 10.1016/j.heares.2019.107773. [DOI] [PMC free article] [PubMed] [Google Scholar]
  30. Morimoto, T., Fujisaka, Y., Okamoto, Y., & Irino, T. (2019). Rising-frequency chirp stimulus to effectively enhance wave-I amplitude of auditory brainstem response. Hearing Research, 377, 104–108. 10.1016/j.heares.2019.03.016. [DOI] [PubMed] [Google Scholar]
  31. Motlagh Zadeh, L., Silbert, N. H., Sternasty, K., Swanepoel, D. W., & Hunter, L. L. (2019). Extended high-frequency hearing enhances speech perception in noise. The Journal of the Acoustical Society of America, 146, 205–215. [DOI] [PMC free article] [PubMed] [Google Scholar]
  32. Nuttall, H. E., Moore, D. R., Barry, J. G., Krumbholz, K., & de Boer, J. (2015). The influence of cochlear spectral processing on the timing and amplitude of the speech-evoked auditory brain stem response. Journal of Neurophysiology, 113(10), 3683–3691. 10.1152/jn.00548.2014. [DOI] [PMC free article] [PubMed] [Google Scholar]
  33. Patro, C., Monfiletto, A., Singer, A., Srinivasan, N. K., & Mishra, S. K. (2024). Midlife speech perception deficits: impact of extended high-frequency hearing, peripheral neural function, and cognitive abilities. Ear and Hearing, 45(5), 1149–1164. 10.1097/AUD.0000000000001504. [DOI] [PubMed] [Google Scholar]
  34. Polspoel, S., Kramer, S. E., van Dijk, B., & Smits, C. (2022). The importance of extended high-frequency speech information in the recognition of digits, words, and sentences in quiet and noise. Ear and Hearing, 43(3), 913–920. 10.1097/AUD.0000000000001142. [DOI] [PubMed] [Google Scholar]
  35. Schaette, R., & McAlpine, D. (2011). Tinnitus with a normal audiogram: physiological evidence for hidden hearing loss and computational model. The Journal of Neuroscience, 31(38), 13452–13457. 10.1523/JNEUROSCI.2156-11.2011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  36. Shaw, G. M., Jardine, C. A., & Fridjhon, P. (1996). A pilot investigation of high-frequency audiometry in obscure auditory dysfunction (OAD) patients. British Journal of Audiology, 30(4), 233–237. 10.3109/03005369609076770. [DOI] [PubMed] [Google Scholar]
  37. Stamper, G. C., & Johnson, T. A. (2015). Auditory function in normal-hearing, noise-exposed human ears. Ear and Hearing, 36(2), 172–184. 10.1097/AUD.0000000000000107. [DOI] [PMC free article] [PubMed] [Google Scholar]

Articles from Journal of the American Academy of Audiology are provided here courtesy of American Academy of Audiology