Skip to main content
Blood Advances logoLink to Blood Advances
. 2026 Sep 19;10(22):7536–7542. doi: 10.1182/bloodadvances.2026019945

Systematic review and meta-analysis of hypersensitivity reactions after high-dose IV iron

Stephen Divers 1, Christopher Elder 2, Patrick C Foy 3, Jason A Freed 4, Brooke Peters 5, Johannes Pöhlmann 6, Richard F Pollock 6,∗
PMCID: PMC13782881  PMID: 42747867

Visual Abstract

graphic file with name BLOODA_ADV-2026-019945-ga1.webp

Abstract

Serious or severe hypersensitivity reactions (HSRs) are uncommon with modern IV iron formulations but, when occurring, can be life-threatening or even fatal. We synthesized available data on incidence of serious or severe HSR for ferric derisomaltose (FDI), ferric carboxymaltose (FCM), and ferumoxytol (FER) as treatments for iron deficiency anemia. A systematic literature review for randomized controlled trials (RCTs) was conducted in PubMed, Embase, and Cochrane Central Register of Controlled Trials. From eligible RCTs, proportions of patients experiencing serious or severe HSR after IV iron administration, reported using the Standardized Medical Dictionary for Regulatory Activities Query (SMQ) for anaphylactic reaction, were extracted. A Bayesian random-effects model was used to obtain posterior distributions of HSR incidence and surface under the cumulative ranking curve (SUCRA) plots, ranking formulations by HSR likelihood. Any serious or severe HSR falling under the anaphylactic reaction SMQ was experienced by 0.14% of patients receiving FDI, 0.59% of patients receiving FCM, and 0.50% of patients receiving FER. The meta-analysis indicated a reduced serious or severe HSR risk with FDI vs FCM (0.21; 95% credible interval [CrI], 0.03-1.73) and FER (0.07; 95% CrI, 0.00-1.93). SUCRA plots showed that the likelihood of FDI having the lowest serious or severe HSR incidence was 91.4% (FCM, 4.5%; FER, 4.2%). This meta-analysis of data from RCTs, including 11 268 patients, represents a comprehensive analysis of serious or severe HSRs among available high-dose, rapid-infusion IV iron formulations, detailing an important facet of formulation safety profiles.

Introduction

IV iron is used to treat patients with iron deficiency anemia who are intolerant of or have had an unsatisfactory response to oral iron and patients who have anemia of chronic kidney disease.1 Globally, iron deficiency anemia is extremely common, with an estimated 1.3 billion people affected in 2021 (whereas, iron deficiency without anemia may affect twice this number).2,3 The condition can result from numerous causes, including low iron intake, infection, blood loss, malabsorption, and chronic disease.1 Iron replacement therapy can be provided orally, but such an approach often requires a long duration of treatment with low-dose therapy and is associated with gastrointestinal side effects.1 Alternatively, iron replacement therapy can also be administered IV. The IV formulations are designed to deliver high doses of iron in a stable form with an iron-carbohydrate complex that retains the iron until it is metabolized.1

Some early IV iron formulations were associated with unacceptably high rates of hypersensitivity reactions (HSRs). The majority of such reactions were specifically in response to high-molecular-weight iron dextran, which is no longer commercially available.4 More recently developed iron formulations, including ferric carboxymaltose (FCM), ferric derisomaltose (FDI), and ferumoxytol (FER), can be administered rapidly in higher doses and are associated with substantially lower rates of HSRs than earlier formulations, such as high-molecular-weight iron dextran.5, 6, 7, 8, 9, 10, 11 Low molecular weight iron dextran is also still in relatively common use in the US, although its use has declined from 26.7% of Medicare Part B fee-for-service claims in 2015 to 10.9% in 2025.12, 13, 14 Most acute reactions to modern iron formulations are likely a complement-mediated response known as complement activation-related pseudoallergy (CARPA).15, 16, 17, 18 “Fishbane-type” reactions to IV iron often manifest as transient chest/back tightness and flushing and are believed to be attributable to CARPA reactions.19 These reactions are often self-limiting, nonanaphylactic events. The reduced incidence of HSRs with modern IV iron formulations is largely attributed to the tighter binding of iron within the complex and the low immunogenicity of the carbohydrate moiety.5,6,20,21 Nevertheless, the risk of HSRs, including true anaphylaxis, is not entirely eliminated. Although such events are uncommon, their severity can vary, and true anaphylactic reactions remain potentially life-threatening,22 with some cases resulting in fatalities.23 The inappropriate administration of vasopressors and antihistamines can further exacerbate this risk, escalating mild reactions into serious adverse events.24,25 Better understanding of the signs and symptoms of Fishbane-type vs severe reactions, as well as the appropriate response to each type of reaction, as suggested by a recent multinational nursing consensus,26 will likely contribute to improved management particularly of mild infusion reactions.

The safety and efficacy of modern IV iron formulations have previously been evaluated in systematic literature reviews (SLRs) and meta-analyses. In 2015, a meta-analysis of 103 trials found no difference in severe adverse event rates between IV iron formulations (FCM, FER, iron polymaltose, FDI [formerly known as iron isomaltoside], iron sucrose [IS], iron dextran, or ferric gluconate) and control groups.27 An earlier comparison of FER, FCM, FDI, and IS also found no significant differences in risk.5 However, a 2023 meta-analysis by Kennedy et al reported a significantly lower rate of serious or severe HSRs with FDI (0.14%) vs FCM (1.08%) based on Bayesian inference of proportions.28

As more data on the rates of serious or severe HSRs continue to emerge, meta-analyses to compare these rates between different IV preparations become increasingly valuable to better understand and differentiate their safety profiles. The United States prescribing information for FER currently includes a black box warning for hypersensitivity/anaphylaxis reactions, whereas monitoring and observing for HSRs are recommended in the warnings and precautions section in the US Food and Drug Administration (FDA) labels for FDI and FCM. The aim of this review was to synthesize the available evidence from several randomized controlled trials (RCTs) regarding the incidence of serious or severe HSRs after the administration of FDI, FCM, or FER and to quantify whether the incidence of these reactions differs among these formulations. Low molecular weight iron dextran was not included in the analysis as its approved administration procedure differs materially from FDI, FCM, and FER in that it requires a 25 mg test dose, at least 1 hour of observation before the therapeutic dose, and a maximum labelled daily IV dose of 100 mg.29 Given the challenges around identification and reporting of HSRs in previous studies, part of the primary objective of the present study was to use data exclusively from prospective RCTs, in which reporting is necessarily more scrupulous than in claims databases or retrospective studies. To improve the consistency and robustness of reporting across the included studies, this analysis specifically aimed to quantify the incidence of HSRs classified under the Standardized Medical Dictionary for Regulatory Activities (MedDRA) Query (SMQ) for anaphylactic reaction.

Methods

SLR

The search protocol was prospectively registered in PROSPERO with registration number CRD420251068759.30 In line with the protocol, 3 separate literature searches were conducted to identify RCTs of each of the iron formulations. In the case of FCM and FDI searches, searches were restricted to studies published from 4 November 2020 onward because the searches were otherwise identical to those conducted by Kennedy et al and, therefore, represented an update of the searches conducted previously.28 As Kennedy et al did not include FER, the FER search was conducted de novo for the present study, and no publication date restrictions were applied. Each of the searches was conducted across PubMed (including MEDLINE), the Cochrane Central Register of Controlled Trials, and Embase. Search terms were constructed using a combination of free-text and index terms (Medical Subject Headings terms for PubMed and the Cochrane library and Emtree terms for Embase, with the latter obtained from the corresponding Medical Subject Headings terms using the Embase term mapping tool). Additional studies were identified through reference list checking and searching conference proceedings.

Searches were conducted across all databases on 29 May 2025, and results were imported into Sourcerer (Covalence Research, Harpenden, United Kingdom). Records across all databases were deduplicated within each of the 3 searches, and 2 reviewers independently screened the titles and abstracts of the retrieved records against the prespecified eligibility criteria. These eligibility criteria included restrictions on population, intervention, comparator, outcomes, and study design, as detailed in Table 1. Relevant records proceeded to full-text review by the same independent reviewers, with disagreements at either stage resolved by consensus. Full-text screening decisions again adhered to the prespecified criteria detailed in Table 1.

Table 1.

Exclusion criteria and example reasons for exclusion from the SLR

PICOS component Reason for exclusion Example reasons for exclusion
Population Not in the target population Not in an adult (aged ≥18 years) population with IDA
Intervention Not investigating the target intervention Does not include FDI, FCM, or FER
Comparator Not comparing the intervention with a relevant comparator Compared with placebo, erythropoietin, or red blood cell transfusion
Outcomes Not reporting end point of interest Not reporting serious or severe HSRs in line with the SMQ for anaphylactic reaction
Study design Not an RCT Single-arm study, observational study, or retrospective database analysis
Study design Not in English Original article not written in English or with an English translation available

IDA, iron deficiency anemia; PICOS, population, intervention, comparator, outcomes, and study design.

Data extraction

Data were extracted independently by 2 reviewers. If data were missing, study authors were not contacted for further information. Risk of bias (RoB) was assessed using the Cochrane RoB 2 tool. Study data were assessed by 1 person and checked by ≥1 other person, with disagreements resolved through consensus. The main outcome extracted was the proportion of patients experiencing serious or severe HSRs after administration of IV iron, as reported in primary studies eligible for inclusion using the SMQ for anaphylactic reaction. If data were not reported specifically in line with the anaphylactic reaction SMQ, efforts were made to obtain the incidence of serious or severe events from trial registry data using specific MedDRA terms and the MedDRA browser to map synonyms and lexical variants to the SMQ. Other details extracted included trial details, population details, interventions/comparators, statistical techniques used, and all primary and secondary outcomes, alongside the RoB assessments.

Analysis

A Bayesian meta-analysis was conducted using BUGSnet to compare the safety of different iron formulations.31 The analysis used random-effects models that account for differences between studies and are appropriate for binary outcomes like the presence or absence of serious HSRs using the Bayesian inference-of-proportions approach used in the analysis by Kennedy et al.28,32,33 Several flexible prior assumptions were applied based on individual trial data to guide the model. After running 10 000 tuning and burn-in steps, 100 000 iterations were performed to ensure stable results, confirmed using standard convergence checks.

Outcomes were reported as pairwise relative risks between IV iron formulations with 95% credible intervals (95% CrIs). Visual outputs included heat maps showing how treatments compare in terms of relative risks. In addition, surface under the cumulative ranking curve plots visually ranked each formulation according to its likelihood of causing the fewest serious reactions, providing a visual aid for assessing the treatment hierarchy and the proportion of other treatments outperformed by each treatment.34

Results

SLR

The literature review retrieved 1439, 499, and 963 records across the FCM, FDI, and FER searches, respectively. Duplicate results were removed, and the Preferred Reporting Items for Systematic reviews and Meta-Analyses diagrams for each of the 3 searches are presented in supplemental Figures 1-3. In addition to the SLR and meta-analysis that formed the basis of the current updates for FDI and FCM, the present literature searches also identified 4 relevant RCTs: PREG-01, PHOSPHARE-IBD, RapidIRON, and FIRM.8,35, 36, 37 Across all identified studies, there were 11 268 patients exposed to treatment with the 3 iron formulations (Table 2).

Table 2.

Summary of total patients at risk and patients experiencing any serious or severe adverse reaction falling under the anaphylactic reaction SMQ by iron formulation

Comparator Total patients at risk, n Patients experiencing any serious or severe adverse reaction falling under the anaphylactic reaction SMQ, n (%)
FDI 5077 7 (0.14)
FCM 5194 31 (0.59)
FER 997 5 (0.50)

The FIRM trial (n ≈ 2000) was the only study reporting outcomes for FER that met the inclusion criteria for FER administered by IV injection over ≥15 minutes, in line with the current US label. Three earlier RCTs were identified comparing FER with oral iron in patients with nondialysis-dependent chronic kidney disease or in patients undergoing hemodialysis; however, 510 mg of FER was administered over as little as 17 seconds in these studies, in line with the original FER label. The original label predated a 2015 FDA Drug Safety Communication arising from 79 cases of anaphylactic reactions recorded in the FDA Adverse Event Reporting System, in which the FDA recommended administering FER over ≥15 minutes. These studies were therefore excluded on the grounds of the elevated risk of moderate-to-severe HSRs with the previous, now off-label, administration scheme.

The FIRM trial prospectively adjudicated moderate-to-severe HSR incidence, including anaphylaxis, and hypotension and found nearly identical rates of moderate-to-severe HSRs with FER and FCM (0.6% vs 0.7%), which established the noninferiority of FER and supported clinical equivalence between the 2 formulations with respect to the incidence of moderate-to-severe HSR. However, based on data reported in the primary manuscript and the ClinicalTrials.gov registry, the present analysis identified 5 serious or severe HSR events classified within the anaphylactic reaction SMQ in the FER arm, compared with only 1 such event in the FCM arm. Regarding other outcomes in the FIRM trial, hemoglobin responses were similar, mitigating concerns about confounding because of differences in effectiveness.8

Data analysis

The Bayesian analysis pointed to FDI being the IV iron formulation associated with the lowest incidence of serious or severe HSRs, with relative risks of 0.21 (95% CrI, 0.03-1.73) vs FCM and 0.07 (95% CrI, 0.00-1.93) vs FER. A heat map showing all pairwise comparisons is presented in Figure 1, with the posterior distributions and median relative risks vs FDI presented in Figures 2 and 3, respectively. The corresponding surface under the cumulative ranking curve plots are presented in supplemental Figure 4, showing that there was a 91.4% likelihood that FDI would result in the lowest incidence of serious or severe HSRs, relative to a 4.5% likelihood for FCM and a 4.2% likelihood for FER.

Figure 1.

Figure 1.

FDI is associated with a lower risk of serious or severe HSR than FCM and FER. The relative risk of any serious or severe HSR with treatment relative to comparator can be read from the heat map by reading down the treatment column to the comparator row. For example, to identify the relative risk for FER (treatment) vs FCM (comparator), pick the column marked “FER” and read down to the row marked “FCM” (relative risk of 2.82). Equivalently, when expressed for FCM vs FER, pick the column marked “FCM” and read down to the row marked “FER,” which gives a relative risk of 0.35 (which is the inverse of the relative risk obtained from the approach in the previous sentence, ie, 1/2.82).

Figure 2.

Figure 2.

Posterior distributions indicate lower rates of serious or severe HSRs with FDI than with FCM and FER. The “half-eye” plots show the median, interquartile range (thick line), and 95% CrI (thin line). For each comparison, the distribution of relative risk estimates is shown, with the median relative risk indicated by solid lines and no effect (equivalent to a relative risk of 1) indicated by dashed lines. For both comparisons, most relative risk estimates are <1, that is, indicating a lower risk with FDI relative to each comparator. RR, relative risk.

Figure 3.

Figure 3.

Relative to FDI, median (and IQR) risks of serious or severe HSR are higher with FCM and FER. The dashed vertical line shows risk with FDI. IQR, interquartile range.

Discussion

The present SLR and meta-analysis evaluated the incidence of serious or severe HSRs of 3 modern higher-dose IV iron formulations. We found that FCM and FER had comparable rates of clinically important HSRs, whereas FDI was associated with a lower incidence of serious or severe HSRs than FCM or FER. These findings were consistent with evidence from a large head-to-head RCT comparing FER with FCM (the FIRM trial) and a recent synthesis of RCTs of FCM and FDI using SMQ definitions of anaphylactic reaction.28 Regarding the comparability of HSR incidence after FCM and FER, the FIRM trial reported a comparable number of moderate-to-severe HSRs with FCM and FER (7/1000 [0.70%] treated with FCM vs 6/997 [0.60%] treated with FER). Although the present analysis focused on serious or severe HSRs only (which occurred in 1/1000 [0.10%] patients treated with FCM vs 5/997 [0.50%] patients treated with FER in the FIRM trial), incidence rates with FCM and FER were comparable across all included studies (31/5194 [0.59%] of patients treated with FCM vs 5/997 [0.50%] of patients treated with FER).

The most recent SLR and meta-analysis that collated prospectively collected SMQ-based HSR data, which formed the basis for the current SLR and analysis, identified 15 active-comparator RCTs (N = 10 467) and demonstrated significantly fewer serious or severe HSRs with FDI than FCM (5/3474 [0.14%] vs 29/2683 [1.08%]; Bayesian mean odds ratio, 0.16; 95% highest posterior density interval, 0.05-0.33). Importantly, this analysis aligned outcome definitions to the FDA’s “anaphylactic reaction” SMQ and confined evidence to RCTs to minimize biases inherent to spontaneous reporting. Although most individual trials compared FDI with IS, the aggregate SMQ-based synthesis provides, to our knowledge, the best currently available estimate of relative HSR risk between FDI and FCM.

The results of the present analysis should be interpreted in the broader safety context of IV iron formulations. Serious acute reactions are rare across modern formulations, and mechanistically, many so-called “infusion reactions” represent CARPA rather than immunoglobulin E–mediated anaphylaxis, an important distinction for clinical management. Consensus guidance emphasizes that most reactions are nonallergic, transient, and best managed with temporary interruption of the infusion, providing supportive measures rather than premedication with epinephrine or antihistamines, which can complicate otherwise mild episodes.22,25,26 The low absolute rates of serious or severe HSRs observed across all 3 comparators are consistent with contemporary reviews and guidance.15,19,38 Given the low risk of serious or severe HSRs, clinical treatment choice should consider safety more broadly, including the frequency of mild HSRs. Care should also be taken that staff administering infusions are trained to recognize infusion reactions, distinguish their severity, and choose appropriate interventions, for example, to avoid unnecessarily strong interventions in response to mild reactions.19,26,39

The strengths of the present study include the prospective design of the SLR and meta-analysis, the duplicate screening/extraction, and prioritization of prospectively designed studies reporting serious or severe HSR outcomes in patients. The agreement of a large, blinded RCT (the FIRM trial) for FER vs FCM with a broad SMQ-based RCT synthesis for FDI vs FCM enhances the confidence in the directional conclusions, namely, that serious or severe HSR incidence does not significantly differ between FER and FCM and would be expected to be lower with FDI.

The limitations of the present study arise from the rarity of events and evidence architecture. Even very large RCTs yield very few serious or severe HSRs, widening uncertainty bands and complicating formal network meta-analysis. As in the previous review, the SMQ-based meta-analysis relied on pooled FCM data from the FDA medical review when sponsor-level case data were unavailable, and several included trials comparing FDI used open-label designs, which could bias reporting of softer end points (although SMQ-based serious/severe outcomes mitigate this).28 As for the previous review,28 the small number of events, as well as the RoB in network edges when using odds ratios (necessarily corrected for the small number of events in some formulation comparisons), implied that conventional network meta-analysis was not feasible. Another limitation, as with almost all reviews, was the potential to have missed relevant studies, especially from the gray literature, because search strategies were focused on literature databases. However, given the focus on RCTs in the present review and the consultation of regulatory documents, it was considered unlikely that eligible studies would have been missed.

In conclusion, the present synthesis represents, to our knowledge, the most robust analysis of the incidence of serious or severe HSRs across the 3 modern IV iron formulations currently available in the United States. The analysis suggested that, based on data from >11 000 patients, FDI would represent the iron formulation associated with the lowest risk of serious or severe HSRs when compared with FCM or FER.

Conflict-of-interest disclosure: C.E. is a consultant for and has participated in advisory boards for Pharmacosmos. P.C.F. reports consulting fees from Pharmacosmos, Sobi, Novartis, and Alexion. B.P. served on the speakers' bureaus for Johnson & Johnson, Amgen, Pfizer, and Regeneron; and reports consulting fees from Regeneron and Genentech. J.P. and R.F.P. are full-time employees of Covalence Research. R.F.P. is a director and shareholder of Covalence Research, which received consultancy fees from Pharmacosmos to design and conduct the systematic literature review and meta-analysis and prepare the manuscript. The remaining authors declare no competing financial interests.

Acknowledgments

The authors acknowledge editorial support from Martin Field at Covalence Research, whose assistance was funded through consultancy fees from Pharmacosmos to Covalence Research.

Pharmacosmos funded the design and execution of the systematic literature review and meta-analysis and preparation of the manuscript through consultancy fees to Covalence Research.

Authorship

Contribution: R.F.P. conceptualized and performed the analyses, created the figures, and wrote the manuscript; and S.D., C.E., P.C.F., J.A.F., B.P., and J.P. critically reviewed and commented on the analyses and the manuscript.

Footnotes

Data collected for and analyzed in this study are available from the corresponding author, Richard F. Pollock (pollock@covalence-research.com), on request.

The full-text version of this article contains a data supplement.

Supplementary Material

Supplemental Figures

References

  • 1.Bhandari S, Pereira DIA, Chappell HF, Drakesmith H. Intravenous irons: from basic science to clinical practice. Pharmaceuticals (Basel) 2018;11(3):82. doi: 10.3390/ph11030082. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 2.GBD 2021 Anaemia Collaborators Prevalence, years lived with disability, and trends in anaemia burden by severity and cause, 1990-2021: findings from the Global Burden of Disease Study 2021. Lancet Haematol. 2023;10(9):e713–e734. doi: 10.1016/S2352-3026(23)00160-6. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 3.Al-Naseem A, Sallam A, Choudhury S, Thachil J. Iron deficiency without anaemia: a diagnosis that matters. Clin Med (Lond) 2021;21(2):107–113. doi: 10.7861/clinmed.2020-0582. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 4.Gómez-Ramírez S, Shander A, Spahn DR, et al. Prevention and management of acute reactions to intravenous iron in surgical patients. Blood Transfus. 2019;17(2):137–145. doi: 10.2450/2018.0156-18. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 5.Achebe M, DeLoughery TG. Clinical data for intravenous iron - debunking the hype around hypersensitivity. Transfusion. 2020;60(6):1154–1159. doi: 10.1111/trf.15837. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 6.Blumenstein I, Shanbhag S, Langguth P, Kalra PA, Zoller H, Lim W. Newer formulations of intravenous iron: a review of their chemistry and key safety aspects - hypersensitivity, hypophosphatemia, and cardiovascular safety. Expert Opin Drug Saf. 2021;20(7):757–769. doi: 10.1080/14740338.2021.1912010. [DOI] [PubMed] [Google Scholar]
  • 7.Wolf M, Rubin J, Achebe M, et al. Effects of iron isomaltoside vs ferric carboxymaltose on hypophosphatemia in iron-deficiency anemia: two randomized clinical trials. JAMA. 2020;323(5):432–443. doi: 10.1001/jama.2019.22450. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 8.Adkinson NF, Strauss WE, Macdougall IC, et al. Comparative safety of intravenous ferumoxytol versus ferric carboxymaltose in iron deficiency anemia: a randomized trial. Am J Hematol. 2018;93(5):683–690. doi: 10.1002/ajh.25060. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 9.Auerbach M, Henry D, Derman RJ, Achebe MM, Thomsen LL, Glaspy J. A prospective, multi-center, randomized comparison of iron isomaltoside 1000 versus iron sucrose in patients with iron deficiency anemia; the FERWON-IDA trial. Am J Hematol. 2019;94(9):1007–1014. doi: 10.1002/ajh.25564. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 10.Bhandari S, Kalra PA, Berkowitz M, Belo D, Thomsen LL, Wolf M. Safety and efficacy of iron isomaltoside 1000/ferric derisomaltose versus iron sucrose in patients with chronic kidney disease: the FERWON-NEPHRO randomized, open-label, comparative trial. Nephrol Dial Transpl. 2021;36(1):111–120. doi: 10.1093/ndt/gfaa011. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 11.Wolf M, Auerbach M, Kalra PA, Glaspy JA, Thomsen LL, Bhandari S. Safety of ferric derisomaltose and iron sucrose in patients with iron deficiency anemia: the FERWON-IDA/NEPHRO trials. Am J Hematol. 2021;96(1):E11–E15. doi: 10.1002/ajh.26015. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 12.Wang Y, Beebe J, Numan S. Comparison of healthcare resource utilization, cost of care, and health outcomes associated with different intravenous iron products in heart failure patients with iron deficiency/iron deficiency anemia: a claims database analysis. J Clin Haematol. 2025;5(1):52–61. [Google Scholar]
  • 13.von Drygalski A, Boland P, Maksour M, Polson M, Lewandowska M. Ferric derisomaltose achieves highest likelihood of ≥1000-mg dose administered and lowest outpatient transfusion rates among intravenous iron therapies in women with iron deficiency anemia and abnormal uterine bleeding: a real-world analysis. NCODA. 2026;1(suppl 1) Abstract 50. [Google Scholar]
  • 14.Hambley BC, Anderson KE, Shanbhag SP, Sen AP, Anderson G. Payment incentives and the use of higher-cost drugs: a retrospective cohort analysis of intravenous iron in the Medicare population. Am J Manag Care. 2020;26(12):516–522. doi: 10.37765/ajmc.2020.88539. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 15.Caimmi S, Crisafulli G, Franceschini F, et al. Hypersensitivity to intravenous iron preparations. Children (Basel) 2022;9(10):1473. doi: 10.3390/children9101473. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 16.Szebeni J, Fishbane S, Hedenus M, et al. Hypersensitivity to intravenous iron: classification, terminology, mechanisms and management. Br J Pharmacol. 2015;172(21):5025–5036. doi: 10.1111/bph.13268. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 17.Fortuny J, von Gersdorff G, Lassalle R, et al. Use of intravenous iron and risk of anaphylaxis: a multinational observational post-authorisation safety study in Europe. Pharmacoepidemiol Drug Saf. 2021;30(10):1447–1457. doi: 10.1002/pds.5319. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 18.Faria B, Gaya da Costa M, Poppelaars F, et al. Administration of intravenous iron formulations induces complement activation in-vivo. Front Immunol. 2019;10:1885. doi: 10.3389/fimmu.2019.01885. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 19.Van Doren L, Steinheiser M, Boykin K, Taylor KJ, Menendez M, Auerbach M. Expert consensus guidelines: intravenous iron uses, formulations, administration, and management of reactions. Am J Hematol. 2024;99(7):1338–1348. doi: 10.1002/ajh.27220. [DOI] [PubMed] [Google Scholar]
  • 20.Jahn MR, Andreasen HB, Fütterer S, et al. A comparative study of the physicochemical properties of iron isomaltoside 1000 (Monofer), a new intravenous iron preparation and its clinical implications. Eur J Pharm Biopharm. 2011;78(3):480–491. doi: 10.1016/j.ejpb.2011.03.016. [DOI] [PubMed] [Google Scholar]
  • 21.Auerbach M, Deloughery T. Single-dose intravenous iron for iron deficiency: a new paradigm. Hematology Am Soc Hematol Educ Program. 2016;2016(1):57–66. doi: 10.1182/asheducation-2016.1.57. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 22.Rampton D, Folkersen J, Fishbane S, et al. Hypersensitivity reactions to intravenous iron: guidance for risk minimization and management. Haematologica. 2014;99(11):1671–1676. doi: 10.3324/haematol.2014.111492. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 23.McCulley L, Gelperin K, Bird S, Harris S, Wang C, Waldron P. Reports to FDA of fatal anaphylaxis associated with intravenous iron products. Am J Hematol. 2016;91(12):E496–E497. doi: 10.1002/ajh.24531. [DOI] [PubMed] [Google Scholar]
  • 24.Van Doren L, Auerbach M. IV iron formulations and use in adults. Hematology Am Soc Hematol Educ Program. 2023;2023(1):622–629. doi: 10.1182/hematology.2023000495. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 25.Arastu AH, Elstrott BK, Martens KL, et al. Analysis of adverse events and intravenous iron infusion formulations in adults with and without prior infusion reactions. JAMA Netw Open. 2022;5(3) doi: 10.1001/jamanetworkopen.2022.4488. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 26.Fraser A, Cairnes V, Mikkelsen E, Knellwolf C, Locher R, Andersson M. Understanding and managing infusion reactions and hypophosphataemia with intravenous iron - a nurses’ consensus paper. Nurs Open. 2025;12(4) doi: 10.1002/nop2.70191. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 27.Avni T, Bieber A, Grossman A, Green H, Leibovici L, Gafter-Gvili A. The safety of intravenous iron preparations: systematic review and meta-analysis. Mayo Clin Proc. 2015;90(1):12–23. doi: 10.1016/j.mayocp.2014.10.007. [DOI] [PubMed] [Google Scholar]
  • 28.Kennedy NA, Achebe MM, Biggar P, Pöhlmann J, Pollock RF. A systematic literature review and meta-analysis of the incidence of serious or severe hypersensitivity reactions after administration of ferric derisomaltose or ferric carboxymaltose. Int J Clin Pharm. 2023;45(3):604–612. doi: 10.1007/s11096-023-01548-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 29.AbbVie INFeD (iron dextran injection), for intravenous or intramuscular use: highlights of prescribing information. https://www.accessdata.fda.gov/drugsatfda_docs/label/2024/017441s181lbl.pdf
  • 30.Pollock RF, Divers S, Elder C, Foy P, Peters B, Pöhlmann J. A Systematic Literature Review and Meta-Analysis of Hypersensitivity Reactions After Administration of Ferumoxytol, Ferric Derisomaltose and Ferric Carboxymaltose In Patients With Iron Deficiency Anemia. https://www.crd.york.ac.uk/PROSPERO/view/CRD420251068759
  • 31.Béliveau A, Boyne DJ, Slater J, Brenner D, Arora P. BUGSnet: an R package to facilitate the conduct and reporting of Bayesian network meta-analyses. BMC Med Res Methodol. 2019;19(1):196. doi: 10.1186/s12874-019-0829-2. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 32.Lecoutre B, Derzko G, Grouin JM. Bayesian predictive approach for inference about proportions. Stat Med. 1995;14(9-10):1057–1064. doi: 10.1002/sim.4780140924. [DOI] [PubMed] [Google Scholar]
  • 33.Grant R, Di Tanna GL. 1st ed. CRC Press; 2025. Bayesian Meta-Analysis: A Practical Introduction. [Google Scholar]
  • 34.Salanti G, Nikolakopoulou A, Efthimiou O, Mavridis D, Egger M, White IR. Introducing the treatment hierarchy question in network meta-analysis. Am J Epidemiol. 2022;191(5):930–938. doi: 10.1093/aje/kwab278. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 35.Zoller H, Wolf M, Blumenstein I, et al. Hypophosphataemia following ferric derisomaltose and ferric carboxymaltose in patients with iron deficiency anaemia due to inflammatory bowel disease (PHOSPHARE-IBD): a randomised clinical trial. Gut. 2023;72(4):644–653. doi: 10.1136/gutjnl-2022-327897. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 36.Hansen R, Sommer VM, Pinborg A, et al. Intravenous ferric derisomaltose versus oral iron for persistent iron deficient pregnant women: a randomised controlled trial. Arch Gynecol Obstet. 2023;308(4):1165–1173. doi: 10.1007/s00404-022-06768-x. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 37.Derman RJ, Bellad MB, Somannavar MS, et al. Single-dose intravenous iron vs oral iron for treatment of maternal iron deficiency anemia: a randomized clinical trial. Am J Obstet Gynecol. 2025;233(2):120.e1–120.e18. doi: 10.1016/j.ajog.2025.01.037. [DOI] [PubMed] [Google Scholar]
  • 38.Benson AE, Lo JO, Achebe MO, et al. Management of iron deficiency in children, adults, and pregnant individuals: evidence-based and expert consensus recommendations. Lancet Haematol. 2025;12(5):e376–e388. doi: 10.1016/S2352-3026(25)00038-9. [DOI] [PMC free article] [PubMed] [Google Scholar]
  • 39.Auerbach M, Macdougall IC. Safety of intravenous iron formulations: facts and folklore. Blood Transfus. 2014;12(3):296–300. doi: 10.2450/2014.0094-14. [DOI] [PMC free article] [PubMed] [Google Scholar]

Associated Data

This section collects any data citations, data availability statements, or supplementary materials included in this article.

Supplementary Materials

Supplemental Figures

Articles from Blood Advances are provided here courtesy of The American Society of Hematology

RESOURCES