Abstract
Background
Exercise is widely recommended to maintain lumbar bone mineral density (BMD), the tissue-level mechanical environment generated within the lumbar spine during different exercises remains difficult to assess in vivo. This study integrated individualized musculoskeletal modelling, finite element analysis, and longitudinal quantitative computed tomography (QCT) to characterise exercise-specific lumbar loading patterns and interpret them alongside regional BMD adaptation.
Methods
Ten postmenopausal women with low BMD who completed a 6-month combined exercise intervention were included (ChiCTR2400081574). QCT scans were acquired at baseline and follow-up to quantify BMD changes in the vertebral body (VB) and posterior region (PR). Individualized musculoskeletal models of walking, heel drops, jumping, and resistance exercise were developed to estimate joint reaction forces and muscle forces. These loads were transferred to individualized lumbar finite element models using a MATLAB–Python workflow to calculate segmental and regional von Mises stresses.
Results
Longitudinal QCT revealed that BMD was preserved or increased in the VB, whereas BMD declined in the PR, particularly at L1–L3. Jumping produced the highest peak joint reaction forces and von Mises stresses in the superior lumbar segments, whereas resistance exercise generated the greatest loading at L4–L5. Across all tasks and vertebral levels, von Mises stresses were consistently higher in the VB than in the PR.
Conclusions
Distinct exercise modalities generated different segmental and regional loading environments within the lumbar spine. These mechanical patterns were broadly consistent with the observed regional BMD changes, providing a mechanically informed interpretation of lumbar bone adaptation during exercise.
Trial registration
Chinese Clinical Trial Registry, ChiCTR2400081574 (retrospectively registered 5 March 2024).
Keywords: Lumbar spine, Exercise, Musculoskeletal model, Finite element model, Bone adaptation
Background
Osteoporosis is a systemic metabolic bone disease characterized by reduced bone mineral density (BMD) and deterioration of bone microarchitecture, resulting in increased skeletal fragility and a greater risk of fracture [1]. Approximately one in three women over the age of 50 will experience an osteoporotic fracture. Among common sites of insufficiency fractures [2], the lumbar spine is particularly vulnerable compared to the wrist and hip [3]. Exercise has emerged as a critical non-pharmacological intervention for preserving or improving BMD, as it promotes bone adaptation through mechanical loading without the adverse effects associated with pharmacological therapies [4]. Despite these benefits, the mechanobiological mechanisms through which exercise influences lumbar spine BMD remain incompletely understood. This knowledge gap is primarily attributed to the paucity of robust methodologies capable of linking whole-body exercise tasks to tissue-level mechanical stimuli.
Clinical practice guidelines consistently advocate for exercise training as a viable non-pharmacological strategy for the maintenance or enhancement of BMD in populations with osteopenia or osteoporosis [5]. Nevertheless, the efficacy of various exercise modalities on lumbar BMD demonstrates considerable heterogeneity across the literature [6, 7]. For instance, an investigation into prescribed brisk walking programs yielded no significant effect on lumbar BMD [8]. Similarly, a longitudinal study incorporating heel drops, muscular endurance, and balance exercises reported no significant skeletal adaptations compared to a sedentary control group [9]. In contrast, a six-month randomized controlled trial involving tri-weekly resistance training-comprising exercises such as bench press and leg extensions-demonstrated that while lumbar BMD significantly declined in the placebo group, it was successfully preserved in the intervention cohorts [10]. A systematic review of 75 studies involving postmenopausal women further concluded that multi-component interventions, particularly those combining jumping and resistance exercises, conferred superior benefits to the lumbar spine compared to single-modality protocols [11]. These findings suggest that BMD adaptations are highly sensitive to specific exercise prescriptions [12]. Such variability may be attributed to the divergent mechanical loading profiles imposed upon the lumbar spine by different physical activities. However, there remains a paucity of research on the tissue-level loading associated with various exercise programs, despite these mechanical stimuli being the fundamental drivers of bone adaptation and BMD fluctuations.
Musculoskeletal (MS) models have been extensively utilized to analyse human activities and predict mechanical loading, including intervertebral compression, shear forces, and paravertebral muscle forces during exercise [13]. These analytical frameworks account for complex muscle–muscle and muscle–bone interactions [14, 15]. Researchers have established and validated MS models across various anatomical regions, such as the lumbar spine [16], and wrist [17], to simulate diverse motor tasks and predict joint kinetics and muscle activation patterns. Specifically, whole-body MS models have been employed to estimate lumbar spinal loads and muscular recruitment during asymmetric lifting tasks [18]. However, MS simulations are inherently limited to providing mechanical data at the joint and muscle levels, failing to capture loading characteristics at the bone tissue level [19].
Biomechanical stimuli, specifically stress [20], are more directly associated with the biological mechanisms of bone adaptation and have been demonstrated to influence BMD adaptation [21]. Finite element (FE) analysis is frequently employed to investigate the stress-strain distributions and other mechanical behaviours of bone at the tissue level. Consequently, simulations of bone adaptation have been performed wherein modifications to BMD and microarchitecture are driven by localized mechanical criteria [22–25]. While such simulations can predict BMD and structural distributions consistent with experimental observations [26, 27], the outcomes remain highly sensitive to the complexity of the prescribed loading conditions. The absence of accurate local boundary conditions may result in significant discrepancies between simulation results and actual clinical presentations.
Existing FE–MS coupling studies have demonstrated the feasibility of applying physiologically realistic loads [28–31], yet their integration with longitudinal in vivo bone density measurements remains limited. In particular, the lack of studies that directly connect exercise-specific tissue-level mechanical stimuli with the observed region-specific bone adaptation has hindered translation of biomechanical modelling into clinically meaningful exercise prescription. Therefore, the objective of this study was to establish an individualized multi-scale MS–FE framework and to interpret its mechanical outputs alongside six-month longitudinal QCT-derived BMD changes in the lumbar spine. This study aimed to provide a mechanically informed interpretation of how different exercise modalities may generate distinct segmental and regional loading environments that are broadly consistent with the observed region-specific BMD changes.
Methods
Multi-scale simulation workflow
The MS model was scaled uniformly to each participant based on torso length (Fig. 1(a)) and simulated using collected kinematics and dynamics data (Fig. 1(b)). The individualized lumbar FE model was established based on CT data (Fig. 1(c)). Lumbar spine muscle attachment locations were obtained from the MS model [28, 32] and transferred to the FE model for application of muscle forces (Fig. 1(d)). The degrees of freedom in all directions of the lower surface of the FE model were constrained, and the joint reaction force (JRF) of the MS model was applied as input to the FE model. Translational DOFs at each intervertebral level remained free in the FE model to enable realistic spinal motion and load transfer.
Fig. 1.

Multi-scale model workflow
Study design and imaging
This study used a subset of participants from a previously reported 6-month combined exercise intervention, for which the detailed recruitment process, eligibility criteria, and training protocol have been described elsewhere [33]. Briefly, participants were postmenopausal women with osteopenia, defined by a DXA T-score between − 1.0 and − 2.5. Individuals with secondary osteoporosis, a history of osteoporotic fracture, use of medications affecting bone metabolism, or contraindications to strenuous physical activity were excluded. Before the intervention, participants received exercise familiarization and instruction in correct exercise techniques. The intervention comprised twice-weekly supervised, campus-based training sessions combining rope skipping with vertical landings (5 sets of 15 repetitions), resistance-band exercises (4 sets of 10 repetitions), and stretching. Adherence was monitored using participant diaries. No intervention-related adverse events were observed. The present analysis focused on 10 postmenopausal women with low BMD who completed both baseline and follow-up imaging assessments. To quantify regional changes in BMD, CT scans were collected at baseline and after the intervention, and the lumbar vertebrae were divided into the vertebral body (VB) and posterior region (PR).
Conventional CT scans of the T12–S1 segments were acquired using a CT scanner (Somatom Sensation 64, Siemens, Germany) under a standard in vivo protocol (110 kVp, 20 mAs). Participants were scanned in the supine position, with a manufacturer-provided support pad placed beneath the lumbar region. Additional scan parameters were as follows: slice thickness 0.5 mm, matrix size 512 × 512, and pixel spacing 0.488 × 0.488 mm. QCT measurements were performed by experienced radiologists, and all images were stored in DICOM format.
QCT was calibrated using a three-element hydroxyapatite (HA) phantom with predefined densities of 0, 75, and 150 mg/cm³. The L1-L5 vertebrae were segmented using a fixed-threshold method and manually subdivided into the VB and PR according to anatomical landmarks. The mean Hounsfield unit (HU) value within each regional mask was converted to volumetric BMD (mg/cm³) using the linear calibration relationship between phantom HA density and HU. To ensure spatial consistency between scans, all follow-up CT images were rigidly registered to the baseline scans using a three-dimensional rigid transformation algorithm [34]. The resulting transformation matrix was then applied to the baseline region-of-interest masks to propagate them to the follow-up images. This procedure reduced positional mismatch between scans and minimized manual segmentation bias.
The musculoskeletal model
Experimental data collection
Participant characteristics and the combined exercise intervention have been reported previously [33]. In brief, the present study included 10 women with low bone mass (age 59.56 ± 7.18 years, weight 59.83 ± 7.59 kg, height 160.78 ± 5.45 cm). All participants provided written informed consent before inclusion, and the study was approved by the Ethics Committee of Tianjin University (Approval No. TJUE-2023-113, Registration No. ChiCTR2400081574).
After completion of the 6-month intervention, participants performed four representative tasks for biomechanical analysis. Biomechanical testing comprised three trials of four tasks: walking, heel drops, jumping, and resistance exercise with elastic bands. Walking was performed at a self-selected speed across the force plates. For heel drops, participants rose onto the forefoot and released the heels while keeping the trunk upright. During jumping, participants performed a maximal vertical jump with free arm swing. For the resistance exercise, participants stood on the elastic band, moved both handles from the starting position to above the head and then slowly lower them.
Full-body kinematics and ground-reaction data were acquired synchronously at 100 Hz with a 15-camera VICON system (VICON Motion Systems Ltd., Oxford, UK) and three AMTI BP400600 force plates (Watertown, USA). The kinematic model was defined by 77 retroreflective markers distributed over the head, trunk, upper limbs, pelvis, and lower limbs. Bilateral activity of the longissimus thoracis pars thoracis (LTpT), latissimus dorsi (LD), and external oblique (EO) was recorded at 2000 Hz using six Noraxon electrodes (Fig. 2(a)-(b)).
Fig. 2.

Experimental setup and task-specific musculoskeletal models: a full-body marker set; b electromyography sensor locations c walking; d heel drops; e jumping; f resistance exercise; and g paraspinal muscle groups. MF: multifidus; LTpT: longissimus thoracis pars thoracis; IL: iliocostalis lumborum; LD: latissimus dorsi; QL: quadratus lumborum; Ps: psoas major
Musculoskeletal model construction
The OpenSim model was derived from the full-body spine (FBLS) [35] and our previous implementation [33]. It comprised 21 body segments, 30 degrees of freedom, and 324 muscle–tendon actuators.
Two task-specific MS configurations were used. Impact tasks (walking, heel drops, and jumping) simulations retained the original FBLS joint degrees of freedom (Fig. 2(c)-(e)). For the resistance task, the upper-limb flexion–extension range was expanded from − 90°–90° to − 90°–180° (Fig. 2(f)). Elastic resistance was represented by bilateral springs linking each palm to the ipsilateral calcaneus; tensile testing yielded a rest length of 0.35 m and a stiffness of 28.29 N/m.
All models were scaled to participant anthropometry before simulation. Inverse kinematics (IK), residual reduction algorithm (RRA), and static optimization (SO) were then performed to estimate muscle activations and paraspinal muscle forces during each task [36, 37]. The model calculated muscle forces using the algorithm that minimized the sum of squared muscle activations (Eq. (1) and Eq. (2)) [13].
![]() |
1 |
subject to the following constraints, for j = 1:k.
![]() |
2 |
where n is the number of muscles in the model;
is the activation level of muscle m at a discrete time step,
is its force-length-velocity surface;
is its moment arm about the j joint axis;
is the generalized force acting about the j joint axis; and is a user-defined constant. Joint reaction analysis [38] was subsequently used to calculate lumbar JRFs under the combined effects of kinematics, external loads, and internal muscle forces. The paraspinal muscles included in the model were the multifidus (MF), LTpT, iliocostalis lumborum (IL), latissimus dorsi (LD), quadratus lumborum (QL), and psoas major (Ps). These muscles are shown in Fig. 2(g).
Lumbar spine FE Model
Model construction
Personalized FE models were constructed based on lumbar CT images of 10 subjects. The complete lumbar FE model construction process is shown in Fig. 1(c). The components of the FE model are shown in Fig. 3. The model construction primarily involved the following steps: First, segmentation and reconstruction. The CT images were segmented to reconstruct the three-dimensional geometry of the T12-S1 segments. DICOM format CT images were imported into Mimics Research 21.0 software to delineate the T12-S1 vertebral segments. The segmentation of the T12 and S1 segments was prepared for the subsequent creation of T12-L1 and L5-S1 IVD. Second, smoothing operations. Due to CT resolution and the inherent shape of the lumbar vertebrae, local smoothing operations were performed on the vertebral segments to facilitate subsequent mesh generation. The vertebral features were used to reconstruct the IVD, including the annulus fibrosus, endplates, annular matrix, and nucleus pulposus [39, 40]. The nucleus pulposus occupies approximately 44% of the IVD volume [41, 42]. Additionally, the vertebral bodies were divided into an outer layer of hard cortical bone and an inner layer of less dense cancellous bone, with the cortical bone thickness set to 1 mm. Finally, the ligaments were constructed and the model was meshed. A mesh size of 1.0 mm was adopted based on our previously published mesh-convergence analysis, in which 0.5-, 1.0-, and 1.5-mm lumbar FE meshes were compared and the 1.0-mm mesh provided sufficiently converged mechanical predictions with improved computational efficiency [43]. Vertebral bone was discretized using 4-node linear tetrahedral elements (C3D4), while the IVD matrix was meshed using 8-node linear hexahedral elements with reduced integration (C3D8R), both with a characteristic element size of 1.0 mm.
Fig. 3.

The components of the FE model. ALL: Anterior longitudinal ligament; PLL: Posterior longitudinal ligament; LF: ligamentum flavum; SSL: supraspinal ligament; ISL: interspinous ligaments; ITL: intertransverse ligament; CL: Capsular ligament
Based on previous studies, the endplate thickness of the IVD was set to 0.5 mm, and the articular cartilage thickness was set to approximately 0.2 mm [44, 45]. The annular fibers of the IVD were simulated using 2-node linear truss elements (T3D2) elements, arranged in five layers at an angle of approximately 45° and added to the annulus fibrosus matrix. The ligaments consisted of the anterior longitudinal ligament, posterior longitudinal ligament, ligamentum flavum, supraspinous ligament, interspinous ligament, intertransverse ligament, and capsular ligament. These seven ligaments were defined as T3D2 elements with different cross-sectional areas (CSA). The articular cartilage between the two adjacent vertebrae was defined as surface-to-surface hard contact with a friction coefficient set to 0.1 [46, 47]. The vertebral coordinate systems in the FE models were aligned with the corresponding lumbar joint coordinate definitions in the MS model to ensure consistent transfer of JRFs and muscle attachment locations [48]. The material properties and mesh element settings for all components of the model are listed in Table 1 [49–53].
Table 1.
Material properties and element definitions of the FE model
| Part | Young’s modulus (MPa) | Poisson’s ratio | Cross-section area (mm2) | Element Type | Total number of elements |
|---|---|---|---|---|---|
| Bone: | |||||
| Cortical bone | 12,000 | 0.3 | - | C3D4 | 210,877 |
| Cancellous bone | 100 | 0.2 | - | 314,946 | |
| Posterior region | 3500 | 0.25 | - | 384,065 | |
| Facet cartilage | 24 | 0.4 | - | 543,885 | |
| Endplate | 1000 | 0.4 | - | S4R | 5422 |
| IVD: | |||||
| AF1 | 550 | 0.3 | 0.76 | T3D2 | 1962 |
| AF2 | 502.5 | 0.5928 | 1962 | ||
| AF3 | 455 | 0.4712 | 1962 | ||
| AF4 | 407.5 | 0.3572 | 1962 | ||
| AF5 | 357.5 | 0.16 | 1962 | ||
| Nucleus pulposus | 1 | 0.48 | - | C3D8R | 9300 |
| Annulus fibrosus | 4 | 0.4 | - | 11,739 | |
| Ligament: | |||||
| ALL | 12.8 | 0.3 | 63.7 | T3D2 | 80 |
| PLL | 10 | 20 | 80 | ||
| LF | 10 | 40 | 80 | ||
| SSL | 2.8 | 25 | 80 | ||
| ISL | 2.8 | 30 | 80 | ||
| ITL | 10 | 25 | 80 | ||
| CL | 8 | 30 | 154 | ||
IVD Intervertebral disc, AF, Annulus fibrosus ALL Anterior longitudinal ligament, PLL Posterior longitudinal ligament, LF Ligamentum flavum, SSL, Supraspinal ligament, ISL Interspinous ligament, ITL, Intertransverse ligament, CL Capsular ligament, C3D4, 4-node linear tetrahedral solid elements, S4R 4-node doubly curved shell elements with reduced integration, T3D2 2-node linear truss elements, C3D8R 8-node linear hexahedral elements with reduced integration
The muscle forces and JRFs obtained from the MS model during four exercises were applied to the FE model. Since the magnitude and direction of the paraspinal muscle forces change during exercise, manually creating all paraspinal muscle forces in the FE model is challenging. This study used a plugin [32] to extract the coordinates of each muscle attachment point on the lumbar spine, the direction of muscle fibers, and the magnitude of muscle forces from the MS model. A MATLAB script was then written to locate the surface node in the FE model closest to the attachment point, which was matched as the muscle insertion point [48]. Muscle forces were created in batches using a Python script, applied as point loads with magnitudes and directions corresponding to those obtained from the MS model, as shown in Fig. 1 (d). In all models, the JRF at T12-L1 was applied to the reference point (RP) nodes on the upper surface of the IVD, with the JRFs also being applied as point loads [48], as shown in Fig. 1 (d). By applying JRFs to the upper surface of the IVD, the point loads obtained from the MS model were transferred to the endplate region and then dispersed to the bone surface via mechanical coupling. This loading strategy was used to assess exercise-induced mechanical differences in the lumbar spine and to explore how combined exercise may influence lumbar BMD. To ensure the stability of the FE model, the lower surface of the L5-S1 IVD was fixed, with all six degrees of freedom constrained, as shown in Fig. 1 (d).
Validation
Validation of MS model
Muscle-activation predictions were evaluated against synchronized surface EMG using the direct-comparison procedure described by Beaucage-Gauvreau et al. [54]. After signal processing, the EMG envelopes and the corresponding model-predicted muscle-activation time histories were normalized to their respective peak values within each exercise cycle. Temporal agreement between the two signals was quantified using the maximum cross-correlation coefficient. The analysis included bilateral LTpT, LD, and EO muscles during the four exercise tasks and was repeated across three trials. Cross-correlation coefficients exceeded 0.80 for most muscle–task combinations and reached 0.96 (Fig. 4), indicating good agreement in activation timing and waveform. Full curve-level comparisons and detailed signal-processing procedures have been reported previously by our group [33].
Fig. 4.

Maximum cross-correlation coefficients between normalized EMG envelopes and model-predicted muscle-activation time histories over the complete exercise cycle. W: Walking; HD: Heel drops; J: Jumping; R: Resistance exercise
Validation of FE model
In the FE model, the inferior endplate of L5 was fixed and a pure moment of 7.5 Nm was applied on the superior endplate of L1 to mimic the physiological motions of extension, flexion, lateral bending, and torsion. Under flexion, extension, lateral bending, and torsional loading conditions, the ROMs of each segment were compared with the previous studies [55–60] and showed satisfactory agreement (Fig. 5). Therefore, the lumbar spine FE model was considered suitable for assessing the biomechanical effects of different exercises.
Fig. 5.

Comparison of ROM predicted by the present FE model with values reported in previous studies under flexion–extension (FL–EX), lateral bending, and axial torsion: (a) L1–L2; (b) L2–L3; (c) L3–L4; and (d) L4–L5
Statistical analysis
Data normality was assessed using the Shapiro-Wilk test, supplemented by visual inspection of Q-Q plots. Continuous data are presented as mean ± standard deviation (SD). To evaluate regional changes in BMD over the 6-month intervention, a two-way repeated-measures analysis of variance (RM-ANOVA) was performed separately for each lumbar level, with time (baseline and follow-up) and region (VB and PR) specified as within-subject factors. The time × region interaction was used to determine whether longitudinal BMD changes differed between the VB and PR. In addition, changes in BMD were compared between the VB and PR using paired-samples t-tests. One-way analysis of variance (ANOVA) was used to assess differences in muscle forces, JRFs and volume-weighted average von Mises stress among walking, heel drops, jumping, and resistance exercise. Statistical significance was defined as p < 0.05 for all analyses.
Results
Changes of BMD at two regions
After six months of exercise training, region-specific changes in lumbar vertebral BMD were observed (Table 2). In the VB, the BMD changes ranged from − 0.14 ± 6.22 mg/cm³ at L5 to 2.40 ± 6.25 mg/cm³ at L2. In contrast, the PR consistently exhibited a decrease in BMD across all lumbar levels, with the greatest reduction observed at L3 (–6.57 ± 6.73 mg/cm³). Statistical analysis revealed significant differences between VB and PR in BMD changes at L1 (p = 0.023), L2 (p = 0.012), and L3 (p = 0.038). No significant differences were found at L4 (p = 0.078) and L5 (p = 0.170). These findings suggest that the anterior and posterior regions of the lumbar spine exhibit distinct longitudinal BMD change patterns, with the VB showing relatively better maintenance of, or increased, BMD compared to the PR, particularly at the upper lumbar levels (L1–L3).
Table 2.
Regional BMD of the vertebral body (VB) and posterior region (PR) at baseline and follow-up, with corresponding changes
| Segment | Region | Baseline | Follow-up | Δ |
|---|---|---|---|---|
| L1 | VB | 173.98 ± 15.32bc | 175.52 ± 13.23 bc | 1.54 ± 5.06 |
| PR | 378.83 ± 76.43 bc | 373.35 ± 55.49 bc | -5.48 ± 5.87 | |
| L2 | VB | 181.90 ± 14.36 bc | 184.30 ± 14.38 bc | 2.40 ± 6.25 |
| PR | 403.89 ± 74.39 bc | 397.53 ± 62.47 bc | -6.36 ± 6.34 | |
| L3 | VB | 186.67 ± 13.93 bc | 187.31 ± 9.75 bc | 0.65 ± 6.36 |
| PR | 401.03 ± 62.15 bc | 394.46 ± 57.67 bc | -6.57 ± 6.73 | |
| L4 | VB | 193.46 ± 20.42b | 194.14 ± 17.10b | 0.68 ± 5.19 |
| PR | 407.77 ± 62.37b | 403.09 ± 57.03b | -4.68 ± 6.49 | |
| L5 | VB | 202.12 ± 20.53b | 201.98 ± 13.90b | -0.14 ± 6.22 |
| PR | 367.24 ± 56.65b | 362.78 ± 47.02b | -4.45 ± 6.07 |
VB Vertebral body, PR Posterior region
Δ: change from baseline to follow-up; b: Significant difference in region; c: Significant difference in time × region; The bold values represent the the paired t-test results are significant
Paravertebral muscle forces & joint reaction forces
The JRFs and muscle forces of the lumbar spine exhibited distinct patterns across walking, heel drops, jumping, and resistance exercise (Fig. 6). During walking, the joint reaction forces remained relatively stable with moderate fluctuations throughout the gait cycle, accompanied by low forces. Heel drops produced a sharp peak in JRFs at the moment of impact, with a concurrent transient rise in muscle activation, particularly in the LTpT. Jumping elicited the largest transient peak in JRFs, which exceeded 2000 N, and was accompanied by a pronounced but short-lived spike in muscle forces, especially in the QL, IL and LTpT. Resistance exercise, in contrast, demonstrated sustained high JRFs across the cycle, with values comparable to or exceeding those observed in walking and heel drops. Compared with the other three exercises, muscle forces remained at relatively high levels during resistance training. Moreover, during all four exercises, the JRFs were consistently greater than the paravertebral muscle forces.
Fig. 6.

a The curves of JRF and muscle force during four exercises. b JRF during different exercises. c Paravertebral muscle forces. MF: multifidus; LTpT: longissimus thoracis pars thoracis; IL: iliocostalis lumborum; LD: latissimus dorsi; QL: quadratus lumborum; Ps: psoas major
Peak JRF for each segment during four exercises is shown in Fig. 6(b). The results indicated that during jumping, the JRF for all vertebral segments was significantly greater than walking, heel drops and resistance exercise (p < 0.05), approximately 1.50 to 1.91 times higher. Under heel drop, all segmental JRF values were significantly greater than walking (p < 0.05), approximately 1.23 to 1.27 times higher. Meanwhile, under resistance exercise, the JRF for the L3-L5 segments was significantly greater than walking (p < 0.05), approximately 1.26 to 1.29 times higher. The JRFs exhibited a decreasing trend from L5 to L1 for all the exercises, but there were no statistically significant differences observed among the vertebral segments.
Peak muscle forces of the six paraspinal muscles during the exercises were calculated using a semi-automatic in-house MATLAB algorithm (Fig. 6(c)). There were significant differences in the paraspinal MFs during various exercises. Except for Ps, the forces of the other 5 paraspinal muscles exhibited a pattern in which jumping yielded the highest force with up to 303.00 N. During jumping, the forces of the 5 paraspinal muscles were significantly greater than those during both heel drop and walking (p < 0.01), ranging from 2.12 to 13.97 times higher than heel drop and 1.73 to 3.66 times higher than walking. Additionally, during resistance exercise, the forces of the LTpT and IL were significantly greater than the forces during walking and heel drop (LTpT: 231.79 N vs. 97.96 N vs. 23.67 N, IL: 150.49 N vs. 54.70 N vs. 14.31 N, p < 0.05). However, the force of the Ps during walking and jumping was 30.79 N and 30.02 N, which were significantly higher than those during heel drops (approximately 4.08 and 3.99 times) and resistance exercise (approximately 5.45 and 5.31 times) (p < 0.05).
Different effects of exercise on lumbar segmental biomechanical responses
The finite element results showed significant differences in von Mises stress among the four exercises (Fig. 7). Jumping induced the highest stress in the upper and mid-lumbar vertebrae, with significantly greater values than walking at L1–L4 (p < 0.05 or p < 0.001). Heel drops also generated elevated stress compared with walking, particularly at L1 (p < 0.05). In contrast, resistance exercise exerted more pronounced effects on the lower lumbar region, with greater stress observed at L4–L5 than during walking and jumping, although the differences were not statistically significant. Overall, the four exercises exhibited a similar pattern of volume-weighted average stress across the lumbar segments, characterized by a progressive increase from L1 to L5.
Fig. 7.

Average von Mises stress (MPa, mean ± SD) of L1-L5 segments in four exercise tasks. W: Walking; HD: Heel drops; J: Jumping; R: Resistance exercise; *p < 0.05; **p < 0.001
Different effects of exercise on lumbar regional biomechanical responses
The L1-L5 stress cloud maps of a representative subject in four exercises are shown in Fig. 8. It can be observed that all four exercises generated relatively large stress at the posterior part of the VB. Stress in the L5 segment during jumping reached up to 150 MPa. In addition, the average stress of the L1-L5 segments in the four exercises all showed that stress in the VB was significantly greater than that in the PR (p < 0.05), with VB stresses being 1.92–4.78 times those in the PR. Overall, PR responses were significantly smaller than VB, indicating that the VB bore the majority of the load during the four exercises.
Fig. 8.

von Mises stress distribution results of vertebrae in four exercises (*p < 0.05; **p < 0.001)
Finite element analysis revealed distinct regional differences in the VB and PR during walking, heel drops, jumping and resistance exercise (Table 3). For the VB, jumping produced stress values that were significantly higher than those during walking at L1–L3 (p < 0.05 or p < 0.001). Resistance exercise induced the greatest stress at L4 (8.04 ± 3.65 MPa) and L5 (12.94 ± 5.42 MPa), significantly exceeding walking (p < 0.05). For the PR, stress was consistently lower in magnitude than in VB. Jumping and resistance exercise increased PR stress relative to walking and heel drops at L1–L5, but no statistical differences were found.
Table 3.
Average von Mises stress (MPa, mean ± SD) of different regions in four exercises
| W | HD | J | R | Significance | |
|---|---|---|---|---|---|
| L1VB | 3.25 ± 0.65 | 4.62 ± 0.92 | 6.64 ± 0.97 | 4.44 ± 2.20 | J > W**, HD*, R* |
| L1PR | 0.85 ± 0.34 | 1.04 ± 0.46 | 1.27 ± 0.49 | 1.03 ± 0.53 | |
| L2VB | 3.45 ± 0.93 | 4.56 ± 1.16 | 6.57 ± 1.09 | 4.87 ± 1.82 | J > W**, HD* |
| L2PR | 1.48 ± 0.91 | 1.55 ± 1.17 | 2.10 ± 1.26 | 2.24 ± 2.15 | |
| L3VB | 3.61 ± 0.86 | 4.63 ± 1.43 | 6.49 ± 1.64 | 6.67 ± 2.64 | J, R > W* |
| L3PR | 1.83 ± 0.86 | 1.81 ± 1.15 | 2.69 ± 0.97 | 2.63 ± 1.45 | |
| L4VB | 3.98 ± 1.02 | 4.73 ± 1.56 | 7.12 ± 2.15 | 8.04 ± 3.65 | R > W* |
| L4PR | 1.96 ± 0.86 | 1.94 ± 0.85 | 2.86 ± 1.00 | 3.02 ± 1.37 | |
| L5VB | 5.85 ± 1.55 | 5.59 ± 1.49 | 9.79 ± 4.54 | 12.94 ± 5.42 | R > W*, HD* |
| L5PR | 1.89 ± 0.57 | 1.92 ± 1.01 | 2.64 ± 1.60 | 3.32 ± 2.10 |
W Walking, HD Heel drops, J Jumping, R Resistance exercise
*p < 0.05; **p < 0.001
Discussion
This study integrated individualized MS modelling and FE analysis with longitudinal QCT-derived regional BMD changes, thereby providing a mechanically informed framework for interpreting how exercise-specific internal loading and tissue-level mechanical stimuli may contribute to the observed regional changes in lumbar BMD. Rather than relying on exercise efficacy alone, the combined modelling–imaging strategy helps explain why mechanically distinct exercise modalities may preferentially benefit particular lumbar segments and regions. This is a key added value beyond MS or FE modelling in isolation and addresses a translational gap that has limited the clinically meaningful interpretation of exercise-related spinal adaptation.
Region-specific adaptations were observed after six months of training, with the VB showing preservation or modest gains, particularly at L1–L3, whereas the PR exhibited consistent decreases. Across the four simulated tasks, mechanical stimuli were predominantly distributed within the VB, consistent with trabecular-rich regions being more responsive to osteogenic loading [61, 62]. In contrast, the PR experienced lower stress magnitudes across exercises, which may contribute to its comparatively unfavourable BMD trend [63, 64]. This regional pattern is consistent with established mechanobiological evidence that local mechanical stimuli are associated with load-dependent bone formation and remodeling [65–67].
Exercise-specific loading patterns further indicate that uniform exercise recommendations may be suboptimal. Jumping produced the largest transient JRF peaks and preferentially elevated stresses in the upper and mid-lumbar segments, consistent with its rapid, high-impact loading characteristics. Previous experimental and clinical studies have shown that rapid dynamic loading and higher strain rates are associated with enhanced osteogenic responses, although such benefits depend on the mechanical stimulus remaining within an appropriate physiological and clinically safe loading range [68, 69]. By contrast, resistance exercise generated sustained loading with relatively greater stress in the lower lumbar region (L4–L5), suggesting a different mechanical signature that may be advantageous for segment-dependent bone status [61]. Heel drops provided intermediate impact-driven stimuli, whereas walking produced comparatively low and stable loading [70]. Collectively, these results demonstrate that mechanically distinct exercise modalities impose heterogeneous stimuli across lumbar regions that cannot be captured by clinical imaging or motion analysis alone [71, 72].
From a clinical perspective, the proposed framework suggests that exercise selection may influence the distribution of mechanical stimuli across lumbar segments and regions. Instead of prescribing exercise solely on the basis of type or intensity, the results suggest that exercise selection may be guided by the mechanical demands imposed on specific lumbar regions. For example, jumping increased mechanical stimuli more prominently in upper lumbar vertebral bodies, whereas resistance exercise produced sustained loading and relatively higher stresses in the lower lumbar segments compared with jumping. Such regional specificity provides a mechanistic basis for interpreting exercise-related loading in relation to individual bone status, particularly when its longitudinal change varies across lumbar levels. Although the current framework is not yet designed for prospective prediction, it should be regarded as providing a mechanistically informed interpretation of lumbar adaptation.
This study has several limitations. First, subject-specific MS and FE model generation remains time-consuming under the current workflow, limiting scalability to larger cohorts. Recent advances in automated segmentation and FE model generation, however, may substantially improve the efficiency and scalability of personalized biomechanical modelling [73]. Second, a formal association between stress and longitudinal BMD change was not examined. BMD represents only one component of bone adaptation, while vertebral mechanical competence is also influenced by bone geometry and microarchitecture. Therefore, a correlation based solely on stress and BMD change could provide an incomplete representation of the relationship between mechanical loading and bone adaptation. Third, although longitudinal QCT outcomes support the mechanical interpretation, prospective validation in larger and more diverse populations will be necessary before clinical translation to predictive prescription.
Conclusions
This study demonstrates the potential of integrating MS modelling, FE analysis, and longitudinal QCT imaging to jointly characterize exercise-specific internal loading and regional changes in lumbar BMD. While MS models quantify exercise-specific internal loading and FE models resolve tissue-level mechanical responses, their integration with observed regional BMD changes over six months enables a mechanically interpretable link from exercise to stimulus and to adaptation. The results indicate that different exercise modalities generate distinct regional mechanical environments: jumping preferentially increased mechanical stimuli in upper lumbar vertebral bodies, whereas resistance exercise imposed more sustained loading in lower lumbar segments. These mechanical signatures are consistent with the region-specific BMD changes observed on follow-up QCT. Overall, the proposed framework provides a mechanically informed interpretation of exercise-related lumbar adaptation and may help guide future research on spinal bone health.
Acknowledgements
The authors would like to acknowledge all participants involved in this study, as well as Meng'en Huang from Tianjin University and the exercise trainers involved in the intervention. We would also like to thank the Tianjin Medical University General Hospital for providing the QCT scanner.
Abbreviations
- BMD
Bone mineral density
- QCT
Quantitative computed tomography
- VB
Vertebral body
- PR
Posterior region
- MS
Musculoskeletal
- FE
Finite element
- DOF
Degree of freedom
- JRF
Joint reaction force
- EMG
Electromyography
- IK
Inverse kinematics
- RRA
Residual reduction algorithm
- SO
Static optimization
- MF
Multifidus
- LTpT
Longissimus thoracis pars thoracis
- IL
Iliocostalis lumborum
- EO
external oblique
- LD
Latissimus dorsi
- QL
Quadratus lumborum
- Ps
Psoas major
- IVD
Intervertebral disc
- AF
Annulus fibrosus
- ALL
Anterior longitudinal ligament
- PLL
Posterior longitudinal ligament
- LF
Ligamentum flavum
- SSL
Supraspinal ligament
- ISL
Interspinous ligament
- ITL
Intertransverse ligament
- CL
Capsular ligament
- CSA
Cross-sectional area
- ROM
Range of motion
- ANOVA
Analysis of variance
- RP
Reference point
Authors' contributions
Conceptualisation: XYX, SZL, JD; Data curation: XYX, SZL, PD, JYD; Formal analysis: XYX, SZL, PD, JYD; Funding acquisition: JD; Investigation: XYX, SZL, PD, JYD; Methodology: XYX, JD; Project administration: JD; Resources: JD; Software: XYX; Supervision: RX, SL, VS, LM, JD, DM; Validation: XYX, JD; Writing–original draft: XYX; Writing–review & editing: RX, SL, VS, LM, JD, DM. All authors read and approved the final manuscript.
Funding
This study was supported by the Natural Science Fund Program of China [12302420] and Key Program of Tianjin Natural Science Foundation [23JCZDJC00830, 24JCYBJC01370].
Data availability
The datasets generated and/or analysed during the current study are not publicly available due to concerns regarding patient privacy and confidentiality but are available from the corresponding author on reasonable request.
Declarations
Ethics approval and consent to participate
This study was approved by the Ethics Committee of the Medical School, Tianjin University (Approval No. TJUE-2023-113). All procedures performed in this study involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Written informed consent was obtained from all participants prior to participation.
Consent for publication
Written informed consent for publication was obtained from all participants prior to their inclusion in the study.
Competing interests
The authors declare no competing interests.
Footnotes
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Xiaoyu Xia and Shizhong Liu contributed equally to this work.
Lin Meng and Juan Du contributed equally to this work.
Contributor Information
Lin Meng, Email: Linmeng@tju.edu.cn.
Juan Du, Email: j_du@tju.edu.cn.
References
- 1.On Osteoporosis NCDP, Prevention D. Osteoporosis prevention, diagnosis, and therapy. JAMA. 2001;285(6):785–95. [DOI] [PubMed] [Google Scholar]
- 2.Sözen T, Özışık L, Başaran NÇ. An overview and management of osteoporosis. Eur J Rheumatol. 2016;4(1):46. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 3.Rachner TD, Khosla S, Hofbauer LC. Now and the future. Lancet. 2011;377(9773):1276–87. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Zhao R, Zhao M, Xu Z. The effects of differing resistance training modes on the preservation of bone mineral density in postmenopausal women: A meta-analysis. Osteoporos Int. 2015;26(5):1605–18. [DOI] [PubMed] [Google Scholar]
- 5.Mohebbi R, Shojaa M, Kohl M, Von Stengel S, Jakob F, Kerschan-Schindl K, et al. Exercise training and bone mineral density in postmenopausal women: An updated systematic review and meta-analysis of intervention studies with emphasis on potential moderators. Osteoporos Int. 2023;34(7):1145–78. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 6.Zhang S, Huang X, Zhao X, Li B, Cai Y, Liang X, et al. Effect of exercise on bone mineral density among patients with osteoporosis and osteopenia: A systematic review and network meta-analysis. J Clin Nurs. 2022;31(15–16):2100–11. [DOI] [PubMed] [Google Scholar]
- 7.Hejazi K, Askari R, Hofmeister M. Effects of physical exercise on bone mineral density in older postmenopausal women: A systematic review and meta-analysis of randomized controlled trials. Archives Osteoporos. 2022;17(1):102. [DOI] [PubMed] [Google Scholar]
- 8.Brooke-Wavell K, Jones PR, Hardman AE. Brisk walking reduces calcaneal bone loss in post-menopausal women. Clin Sci. 1997;92(1):75–80. [DOI] [PubMed] [Google Scholar]
- 9.Marques EA, Mota J, Machado L, Sousa F, Coelho M, Moreira P, et al. Multicomponent training program with weight-bearing exercises elicits favorable bone density, muscle strength, and balance adaptations in older women. Calcif Tissue Int. 2011;88(2):117–29. [DOI] [PubMed] [Google Scholar]
- 10.Chuin A, Labonte M, Tessier D, Khalil A, Bobeuf F, Doyon CY, et al. Effect of antioxidants combined to resistance training on bmd in elderly women: A pilot study. Osteoporos Int. 2009;20(7):1253–8. [DOI] [PubMed] [Google Scholar]
- 11.Shojaa M, Von Stengel S, Schoene D, Kohl M, Kemmler W. Effect of different types of exercise on bone mineral density in postmenopausal women: A systematic review and meta-analysis. Osteologie. 2020;29(03):179–93. [Google Scholar]
- 12.Fountoulis G, Kerenidi T, Kokkinis C, Georgoulias P, Thriskos P, Gourgoulianis K, et al. Assessment of bone mineral density in male patients with chronic obstructive pulmonary disease by dxa and quantitative computed tomography. Int J Endocrinol. 2016;2016(1):6169721. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 13.Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, et al. Opensim: Open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng. 2007;54(11):1940–50. [DOI] [PubMed] [Google Scholar]
- 14.Honegger JD, Actis JA, Gates DH, Silverman AK, Munson AH, Petrella AJ. Development of a multiscale model of the human lumbar spine for investigation of tissue loads in people with and without a transtibial amputation during sit-to-stand. Biomech Model Mechanobiol. 2021;20(1):339–58. [DOI] [PubMed] [Google Scholar]
- 15.Abe T, Kumagai K, Brechue WF. Fascicle length of leg muscles is greater in sprinters than distance runners. Med Sci Sports Exerc. 2000;32(6):1125–9. [DOI] [PubMed] [Google Scholar]
- 16.Christophy M, Faruk Senan NA, Lotz JC, OM, O’reilly. A musculoskeletal model for the lumbar spine. Biomech Model Mechanobiol. 2012;11(1–2):19–34. [DOI] [PubMed] [Google Scholar]
- 17.Mcfarland DC, Binder-Markey BI, Nichols JA, Wohlman SJ, De Bruin M, Murray WM. A musculoskeletal model of the hand and wrist capable of simulating functional tasks. IEEE Trans Biomed Eng. 2023;70(5):1424–35. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Kim HK, Zhang Y. Estimation of lumbar spinal loading and trunk muscle forces during asymmetric lifting tasks: Application of whole-body musculoskeletal modelling in opensim. Ergonomics. 2017;60(4):563–76. [DOI] [PubMed] [Google Scholar]
- 19.Favier CD, Finnegan ME, Quest RA, Honeyfield L, Mcgregor AH, Phillips ATM. An open-source musculoskeletal model of the lumbar spine and lower limbs: A validation for movements of the lumbar spine. Comput Methods Biomech BioMed Eng. 2021;24(12):1310–25. [DOI] [PubMed] [Google Scholar]
- 20.Kerner J, Huiskes R, Van Lenthe GH, Weinans H, Van Rietbergen B, Engh CA, et al. Correlation between pre-operative periprosthetic bone density and post-operative bone loss in tha can be explained by strain-adaptive remodelling. J Biomech. 1999;32(7):695–703. [DOI] [PubMed] [Google Scholar]
- 21.Pizzolato C, Lloyd DG, Barrett RS, Cook JL, Zheng MH, Besier TF, et al. Bioinspired technologies to connect musculoskeletal mechanobiology to the person for training and rehabilitation. Front Comput Neurosci. 2017;11:96. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 22.Fyhrie DP, Carter DR. A unifying principle relating stress to trabecular bone morphology. J Orthop Res. 1986;4(3):304–17. [DOI] [PubMed] [Google Scholar]
- 23.Adachi T, Tomita Y, Sakaue H, Tanaka M. Simulation of trabecular surface remodeling based on local stress nonuniformity. JSME Int J C. 1997;40(4):782–92. [Google Scholar]
- 24.Du J, Li S, Silberschmidt VV. Remodelling of trabecular bone in human distal tibia: A model based on an in-vivo hr-pqct study. J Mech Behav Biomed Mater. 2021;119:104506. [DOI] [PubMed] [Google Scholar]
- 25.Tsubota K, Adachi T, Tomita Y. Functional adaptation of cancellous bone in human proximal femur predicted by trabecular surface remodeling simulation toward uniform stress state. J Biomech. 2002;35(12):1541–51. [DOI] [PubMed] [Google Scholar]
- 26.Du J, Hartley C, Brooke-Wavell K, Paggiosi MA, Walsh JS, Li S, et al. High-impact exercise stimulated localised adaptation of microarchitecture across distal tibia in postmenopausal women. Osteoporos Int. 2021;32(5):907–19. [DOI] [PubMed] [Google Scholar]
- 27.Du J, Brooke-Wavell K, Paggiosi MA, Hartley C, Walsh JS, Silberschmidt VV, et al. Characterising variability and regional correlations of microstructure and mechanical competence of human tibial trabecular bone: An in-vivo hr-pqct study. Bone. 2019;121:139–48. [DOI] [PubMed] [Google Scholar]
- 28.Phillips AT, Villette CC, Modenese L. Femoral bone mesoscale structural architecture prediction using musculoskeletal and finite element modelling. Int Biomech. 2015;2(1):43–61. [Google Scholar]
- 29.Geraldes DM, Modenese L, Phillips ATM. Consideration of multiple load cases is critical in modelling orthotropic bone adaptation in the femur. Biomech Model Mechanobiol. 2016;15(5):1029–42. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 30.Carpenedo L, Ignasiak D, Remus R, Barbera LL, Carpenedo, et al. Ann Biomed Eng. 2025;53(11):2883–910. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Nispel K, Lerchl T, Senner V, Kirschke JS. Recent advances in coupled mbs and fem models of the spine—a review. Bioengineering. 2023;10(3):315. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Van Arkel RJ, Modenese L, Phillips AT, Jeffers JR. Hip abduction can prevent posterior edge loading of hip replacements. J Orthop Res. 2013;31(8):1172–9. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 33.Liu S, Xia X, Nie Y, Huang M, Meng L, Du J. Musculoskeletal model predicted paraspinal loading may quick estimate the effect of exercise on spine bmd. Front Bioeng Biotechnol. 2024;12:1464067. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 34.Christen P, Ito K, Ellouz R, Boutroy S, Sornay-Rendu E, Chapurlat RD, et al. Bone remodelling in humans is load-driven but not lazy. Nat Commun. 2014;5(1):4855. [DOI] [PubMed] [Google Scholar]
- 35.Raabe ME, Chaudhari AM. An investigation of jogging biomechanics using the full-body lumbar spine model: Model development and validation. J Biomech. 2016;49(7):1238–43. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 36.Ueno R, Ishida T, Yamanaka M, Taniguchi S, Ikuta R, Samukawa M, et al. Quadriceps force and anterior tibial force occur obviously later than vertical ground reaction force: A simulation study. BMC Musculoskelet Disord. 2017;18:1–8. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Mokhtarzadeh H, Yeow CH, Goh JCH, Oetomo D, Malekipour F, Lee PV-S. Contributions of the soleus and gastrocnemius muscles to the anterior cruciate ligament loading during single-leg landing. J Biomech. 2013;46(11):1913–20. [DOI] [PubMed] [Google Scholar]
- 38.Aghdam HA, Haghighat F, Rezaie M, Kavyani M, Karimi MT. Comparison of the knee joint reaction force between individuals with and without acute anterior cruciate ligament rupture during walking. J Orthop Surg Res. 2022;17(1):1–11. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 39.Schmidt H, Heuer F, Simon U, Kettler A, Rohlmann A, Claes L, et al. Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus. Clin Biomech Elsevier Ltd. 2006;21(4):337–44. [DOI] [PubMed] [Google Scholar]
- 40.Denoziere G, Ku DN. Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc. J Biomech. 2006;39(4):766–75. [DOI] [PubMed] [Google Scholar]
- 41.Kurutz M. Finite element modelling of human lumbar spine. Finite element analysis, 2010: pp. 209–236.
- 42.Kurutz M, Oroszváry L. Finite element modeling and simulation of healthy and degenerated human lumbar spine. Finite Element Analysis—From Biomedical Applications to Industrial Developments, 2012: pp. 193–216.
- 43.Du J, Dong H, Huang ME, Silberschmidt VV, Meng L, Miao J. Regional variations of mechanical responses of ivd to 7 different motions: An in vivo study combined with fea and dfis. J Mech Behav Biomed Mater. 2024;160:106785. [DOI] [PubMed] [Google Scholar]
- 44.Zou D, Yue L, Fan Z, Zhao Y, Leng H, Sun Z, et al. Biomechanical analysis of lumbar interbody fusion cages with various elastic moduli in osteoporotic and non-osteoporotic lumbar spine: A finite element analysis. Global Spine J. 2024;14(7):2053–61. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 45.Spina NT, Moreno GS, Brodke DS, Finley SM, Ellis BJ. Biomechanical effects of laminectomies in the human lumbar spine: A finite element study. Spine J. 2021;21(1):150–9. [DOI] [PubMed] [Google Scholar]
- 46.Khuyagbaatar B, Kim K, Kim YH. Recent developments in finite element analysis of the lumbar spine. Int J Precis Eng Manuf. 2024;25(2):487–96. [Google Scholar]
- 47.Leszczynski A, Meyer F, Charles YP, Deck C, Willinger R. Development of a flexible instrumented lumbar spine finite element model and comparison with in-vitro experiments. Comput Methods Biomech BioMed Eng. 2022;25(2):221–37. [DOI] [PubMed] [Google Scholar]
- 48.Favier CD, Mcgregor AH, Phillips AT. Maintaining bone health in the lumbar spine: Routine activities alone are not enough. Front Bioeng Biotechnol. 2021;9:661837. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 49.Pitzen T, Geisler F, Matthis D, Müller-Storz H, Barbier D, Steudel WI, et al. A finite element model for predicting the biomechanical behaviour of the human lumbar spine. Control Eng Pract. 2002;10(1):83–90. [Google Scholar]
- 50.Schmidt H, Shirazi-Adl A, Galbusera F, Wilke HJ. Response analysis of the lumbar spine during regular daily activities–a finite element analysis. J Biomech. 2010;43(10):1849–56. [DOI] [PubMed] [Google Scholar]
- 51.Shin DS, Lee K, Kim D. Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Comput Aided Des. 2007;39(7):559–67. [Google Scholar]
- 52.Wagnac E, Arnoux PJ, Garo A, Aubin CE. Finite element analysis of the influence of loading rate on a model of the full lumbar spine under dynamic loading conditions. Med Biol Eng Comput. 2012;50(9):903–15. [DOI] [PubMed] [Google Scholar]
- 53.Zhao G, Wang L, Wang H, Li C, Yuan S, Sun J, et al. Biomechanical effects of multi-segment fixation on lumbar spine and sacroiliac joints: A finite element analysis. Orthop Surg. 2024;16(10):2499–508. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 54.Beaucage-Gauvreau E, Robertson WS, Brandon SC, Fraser R, Freeman BJ, Graham RB, et al. Validation of an opensim full-body model with detailed lumbar spine for estimating lower lumbar spine loads during symmetric and asymmetric lifting tasks. Comput Methods Biomech BioMed Eng. 2019;22(5):451–64. [DOI] [PubMed] [Google Scholar]
- 55.Shim CS, Park SW, Lee SH, Lim TJ, Chun K, Kim DH. Biomechanical evaluation of an interspinous stabilizing device, locker. Spine. 2008;33(22):E820–7. [DOI] [PubMed] [Google Scholar]
- 56.Panjabi MM. Cervical spine models for biomechanical research. Spine. 1998;23(24):2684–700. [DOI] [PubMed] [Google Scholar]
- 57.Rana M, Roy S, Biswas P, Biswas SK, Biswas JK. Design and development of a novel expanding flexible rod device (frd) for stability in the lumbar spine: A finite-element study. Int J Artif Organs. 2020;43(12):803–10. [DOI] [PubMed] [Google Scholar]
- 58.Yamamoto I, Panjabi MM, Crisco T, Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine. 1989;14(11):1256–60. [DOI] [PubMed] [Google Scholar]
- 59.Gong Z, Chen Z, Feng Z, Cao Y, Jiang C, Jiang X. Finite element analysis of 3 posterior fixation techniques in the lumbar spine. Orthopedics. 2014;37(5):e441–8. [DOI] [PubMed] [Google Scholar]
- 60.Renner SM, Natarajan RN, Patwardhan AG, Havey RM, Voronov LI, Guo BY, et al. Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine. J Biomech. 2007;40(6):1326–32. [DOI] [PubMed] [Google Scholar]
- 61.Rubin CT, Lanyon LE. Regulation of bone formation by applied dynamic loads. JBJS. 1984;66(3):397–402. [PubMed] [Google Scholar]
- 62.Frost HM. Bone’s mechanostat: A 2003 update. Anat record part a: discoveries Mol Cell evolutionary biology: official publication Am association anatomists. 2003;275(2):1081–101. [DOI] [PubMed] [Google Scholar]
- 63.Brinckmann P, Grootenboer H. Change of disc height, radial disc bulge, and intradiscal pressure from discectomy an in vitro investigation on human lumbar discs. Spine. 1991;16(6):641–6. [DOI] [PubMed] [Google Scholar]
- 64.Adams MA, Dolan P. Biomechanics of vertebral compression fractures and clinical application. Arch Orthop Trauma Surg. 2011;131(12):1703–10. [DOI] [PubMed] [Google Scholar]
- 65.Grosland NM, Goel VK. Vertebral endplate morphology follows bone remodeling principles. Spine. 2007;32(23):E667–73. [DOI] [PubMed] [Google Scholar]
- 66.Huiskes R, Weinans H, Grootenboer H, Dalstra M, Fudala B, Slooff T. Adaptive bone-remodeling theory applied to prosthetic-design analysis. J Biomech. 1987;20(11–12):1135–50. [DOI] [PubMed] [Google Scholar]
- 67.Rubin CT, Lanyon LE. Regulation of bone mass by mechanical strain magnitude. Calcif Tissue Int. 1985;37(4):411–7. [DOI] [PubMed] [Google Scholar]
- 68.Turner CH, Owan I, Takano Y. Mechanotransduction in bone: Role of strain rate. Am J Physiology-Endocrinology Metabolism. 1995;269(3):E438–42. [DOI] [PubMed] [Google Scholar]
- 69.Heikkinen R, Vihriälä E, Vainionpää A, Korpelainen R, Jämsä T. Acceleration slope of exercise-induced impacts is a determinant of changes in bone density. J Biomech. 2007;40(13):2967–74. [DOI] [PubMed] [Google Scholar]
- 70.Winter DA. Biomechanics and motor control of human movement. Wiley; 2009.
- 71.Mcgill S. Low back disorders: Evidence-based prevention and rehabilitation. Human Kinetics; 2015.
- 72.Schoenau E. From mechanostat theory to development of the functional muscle-bone-unit. J Musculoskel Neuronal Interact. 2005;5(3):232–8. [PubMed] [Google Scholar]
- 73.Ahmadi M, Zhang X, Lin M, Tang Y, Engeberg ED, Hashemi J, et al. Automated finite element modeling of the lumbar spine: A biomechanical and clinical approach to spinal load distribution and stress analysis. World Neurosurgery; 2025. p. 124236. [DOI] [PubMed]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Data Availability Statement
The datasets generated and/or analysed during the current study are not publicly available due to concerns regarding patient privacy and confidentiality but are available from the corresponding author on reasonable request.