. 2026 Nov 24;245(1):16. doi: 10.1007/s00221-026-07442-3

Location-dependent effects of vibrotactile stimulation on finger position sense acuity and related somatosensory cortical responses

Jinseok Oh 1,✉, Jiapeng Xu 2, Arash Mahnan 3, Hannah J Block 4, Jürgen Konczak 2,5
PMCID: PMC13796721  PMID: 43076914

Abstract

Finger position sense is a crucial proprioceptive modality for fine motor control. At present, there is inconclusive evidence to what extent input from the finger’s cutaneous mechanoreceptors contributes to the sense’s acuity and whether specific regions of the finger are more sensitive than others in altering finger position sense. To address this knowledge gap, this study examined how vibrotactile stimulation (VTS) applied to two locations of the index finger affected finger position sense acuity. As an electrocortical measure, somatosensory evoked potentials (SEP) before and after administering VTS were recorded to determine site-specific VTS-induced effects on SEP latency and amplitude. Thirty-three neurologically normal healthy adults were assigned to two groups and received VTS either on the tip or the lateral side of the index finger. Without and with VTS, finger position sense bias, indicating the angular difference between perceived and physical position, was measured using a psychophysical assessment system where participants had to judge the position of their occluded finger relative to two visible areas (left or right). The main results are: First, changes in the magnitude of position-sense bias differed significantly between stimulation sites, showing a decrease with lateral VTS and an increase with fingertip VTS. Second, changes in positive SEP amplitude at 100 ms after stimulation onset (P100) were significantly different between stimulation sites and were characterized by an increase after lateral and a decrease after fingertip vibration. These findings indicate that the influence of cutaneous mechanoreceptor stimulation on conscious perception of finger position depends on stimulation location.

Keywords: Proprioception, Somatosensory evoked potentials, Psychophysics, Sensory augmentation

Introduction

The perception of limb movement and position in space are two important submodalities of proprioception (Sherrington 1906). The awareness of where our limbs are in space, even when they are not visible, enables quick yet seamlessly coordinated movements that we make every day. Correct estimation of the hand and finger position without vision is critical for many activities of daily living, such as typing fluently without checking the finger position on a keyboard or maneuvering a steering wheel while focusing on the road.

Perceiving the position of limbs and joints relies on the integration of afferent signals from multiple mechanoreceptors embedded in muscles, tendons, ligaments and the skin. There is inconclusive evidence on the contribution of cutaneous receptors to the limb position sense. For example, Clark and colleagues reported that the awareness of a knee joint position does not depend on cutaneous input (Clark et al. 1979), while another report showed that cutaneous anesthesia induces a temporary impairment of proprioception, similar to the state experienced after a severed ulnar nerve (Moberg 1983). A more quantitative assessment revealed that skin anesthetization increased the error of an ankle joint position matching task (Mildren et al. 2017). On the other hand, introducing tactile input through a sleeve was argued to decrease the error of shoulder joint position matching tasks (Ulkar et al. 2004).

Neurophysiological evidence for the interaction between cutaneous and proprioceptive inputs exists as well. Cutaneous afferents terminate at Brodmann area (BA) 3b within the primary somatosensory cortex (Delhaye et al. 2018), while proprioceptive afferents are transmitted to BA 3a (Ohye and Narabayashi 1979). Evidence of proprioceptive-tactile sensory integration has been reported in studies on primates. Neurons in BA 3b are reciprocally connected to those in BA 3a (Burton and Fabri 1995; Krubitzer and Kaas 1990) with some neurons in primary somatosensory cortex demonstrating responses to both proprioceptive and cutaneous signals (Kim et al. 2015). Behavioral and neurophysiological findings suggest that cutaneous input may play an assistive role when individuals estimate the position of their limbs. For example, a recent study (Mikula et al. 2018) applied vibrotactile stimulation (VTS) at two frequencies (30–300 Hz) to the index finger, which made participants more accurate in locating the fingertip when vision was occluded.

We here examined whether VTS can indeed carry proprioceptive information indicating a specific joint position or if it needs to be understood as an unspecific sensitization of tactile mechanoreceptors. VTS was applied either to the fingertip or to the lateral side of the index finger. To obtain a measure of the cortical response ensuing the possible interaction between cutaneous and proprioceptive afferents, we recorded somatosensory evoked potentials (SEP) to VTS stimuli over somatosensory cortex. Previous research showed that the positive peak at around 100 milliseconds (P100) after a somatosensory stimulus is a prominent mid-latency component indicative of conscious somatosensory processing (Arnfred 2005; Desmedt and Robertson 1977; Eimer and Forster 2003; Kida et al. 2006; Schubert et al. 2006) associated with sensory integration (Tanaka et al. 2008). Consequently, we measured the latency and magnitude of P100 from individuals who received VTS at different areas of the index finger. Our hypothesis was that individuals who get stimulated at the fingertip while estimating a non-visible finger location would exhibit a greater magnitude or shorter latency of P100, compared to those who get stimulated elsewhere.

Method

Participants

A convenience sample of thirty-three healthy individuals (21 females; mean age: 22.9 ± 3.3 years; 2 left-handed) was recruited. Sample size was determined by recruitment feasibility and available resources. Two participants consented to and completed the behavioral assessments but declined EEG recording. Consequently, SEP data were available for 31 participants. All participants had normal or corrected to normal vision and no previous history of neurological disorders. At the time of testing, no participant presented with orthopedic symptoms of their hands that could have influenced perceptual judgment. All participants gave written informed consent in accordance with the Declaration of Helsinki. The study was approved by the Institutional Review Board of the University of Minnesota (STUDY00012576).

Apparatus

A special two-layer tablet stand developed by the authors (Oh et al. 2020) was used to evaluate proprioceptive acuity. A participant’s hand was placed on the base layer (Fig. 1A), which included two pins (Fig. 1B, white dotted circles) positioning the index finger at a fixed angle of 50° relative to the horizontal. After an experimenter verified the hand position, medical tape was applied over the dorsal surface between the proximal and distal interphalangeal joints to secure the finger at the 50° reference position. The top positioning pin was then removed to eliminate a potential tactile cue indicating finger position. The experimenter visually monitored finger position throughout a 50-trial assessment to check for movement. The same 50° reference position was used for every trial of the assessment. A tablet (10.1-inch display; Surface Go, Microsoft, USA) was placed on the cover layer above visually occluding the participant’s hand (Fig. 1A). A piezo haptic actuator (PowerHap 1204, TDK Electronics, Germany; 12 × 4 × 1.8 mm; Fig. 1E) attached to a high voltage piezoelectric driver (BOS 1901, Boréas Technologies, Bromont, Canada; Fig. 1D) was used to apply vibrotactile stimulations.

Fig. 1.

The figure presents a proprioceptive acuity test and its experimental sequence. A participant places a hand beneath a tablet, with the index finger fixed at 50 degrees. The participant judges which of two screen regions covers the finger as the border angle changes. An example response curve plots the percentage of “left” responses against border angle. The 50 percent point gives the perceived finger position; the difference between the 25 and 75 percent points measures uncertainty.A piezoelectric driver and actuator deliver vibration to either the fingertip or the side of the index finger. The protocol proceeds from baseline recording to an assessment without vibration, another recording, and a 20-minute break. Participants then complete an assessment with vibration at one assigned site, followed by a final recording. Each assessment repeats a roughly 20-second task and a 2-second interval 50 times; vibration is applied during the interval in the vibration condition.

Proprioceptive acuity assessment system and the study protocol. A The participant’s dominant hand was placed on the base layer of the tablet stand with a tablet positioned on the cover layer above the hand. B Hand placement was guided by two pins (white dotted circles) at the base layer, achieving a fixed finger position of 50° relative to the horizontal. The range of the border angle (θ) was 0–100°. C An exemplar psychometric function fitted to a participant’s responses (hollow circles). Each response (e.g., “left” or “right”) to the question (“Under which colored region on the screen do you perceive your index finger to be located?”) was recorded. Responses were summarized as the percentage of “left” responses across trials (y-axis). The point of subjective equality (PSE) was the border angle corresponding to the 50% response rate derived from the fitted psychometric curve. UA was the difference in border angle between 75 and 25% points of the fitted psychometric function. ΔPSE was defined as the angular difference between the physical finger position and PSE (PSE − 50°). D and E Device used to administer vibrotactile stimulus (VTS): piezoelectric driver (D) and piezoelectric vibration actuator (E). F and G Two regions of the index finger that received vibration: fingertip (F) and lateral region (G). H Experimental design. Participants undergoing EEG recording went through the same procedure up to the 20-minute break. After the break, based on the predetermined random assignment, participants completed the second proprioceptive acuity assessment with VTS applied to a single site (either lateral or fingertip) during the 2-second intervals between assessment tasks

Following a psychophysical assessment method, a two-colored, half circle display was presented on the tablet. The participant then answered the question: “Under which colored region on the screen do you perceive your index finger to be located?” Based on the participant’s binary response, the border angle (θ, Fig. 1B) was altered in the subsequent trial using a Bayesian-based adaptive algorithm (Prins 2013). With successive correct perceptual judgments, the border angle converged toward the true finger position (50° from the horizontal; see Fig. 1B), whereas incorrect responses caused the border angle to diverge away from that value. A change in the border angle resulted in the corresponding change in the display, with proportions of the two-colored areas reflecting the size of the border angle.

Electroencephalography (EEG) was recorded using a DC amplifier (ANT Neuro, Hengelo, Netherlands) with participants wearing a 64-channel EEG cap (Waveguard by ANT Neuro). EEG signals were recorded from 63 Ag/AgCl pallet electrodes mounted in the cap according to the extended 10–20 international EEG system. The ground electrode was placed on AFz. Skin impedances were kept under 20 kΩ and the sampling frequency during recording was set to 500 Hz.

Experimental design and protocol

The study employed a between-subjects design with two groups. Participants were pseudo-randomly assigned to receive VTS either on the lateral surface or at the tip of the index finger (Fig. 1F and G). Finger position sense acuity was assessed using the tablet-based psychophysical procedure described above (see section Apparatus; for details see Oh et al. 2023). After hand placement and occlusion, participants completed several practice trials followed by 50 test trials of the finger position sense assessment. During testing, participants sat on a comfortable chair with their dominant hand occluded by the tablet. Prior to testing, a participant’s dominant hand was determined by the Edinburgh Handedness Inventory (Oldfield 1971) and the dominant hand was then placed on the tablet stand. Subsequently, assessment started with an initial SEP recording (Baseline), a baseline proprioceptive acuity assessment without VTS (NoVTS) followed by a second SEP recording (Post-NoVTS). The piezo haptic actuator was absent during the baseline proprioceptive acuity assessment. Participants removed their hand from the assessment system during the second SEP recording and the 20-minute break. After the break, the proprioceptive acuity assessment procedure was repeated with VTS. Before this second assessment, the positioning pins were reinserted, the 50° reference position was reverified, and the finger was secured with medical tape before the top positioning pin was removed. For the assessment with VTS, the piezo actuator was secured directly against the skin using medical tape at the assigned site: either the tip of the index finger (Fig. 1F) or the lateral surface between the metacarpophalangeal joint and the proximal interphalangeal joint of the index finger (Fig. 1G). The selection of the stimulus location was based on predetermined pseudorandom assignment. VTS was delivered at 30 Hz for one second during the second half of every 2 s interval between two trials (Fig. 1H, right). Vibration force at the skin-actuator interface was not measured or calibrated. All participants confirmed that the stimuli were clearly perceptible but did not cause any discomfort or pain. After this assessment, the final SEP recording (Post-VTS) for all participants concluded the study.

Recording of somatosensory-evoked potentials

For each recording, the stimulus was presented one hundred times. In both stimulation-site groups, the piezo vibration actuator was placed on the dominant index fingertip and delivered a 300 Hz sinusoidal vibration with a rectangular envelope. The frequency was set to stimulate Pacinian corpuscles (Bolanowski and Zwislocki 1984; Vallbo and Johansson 1984). The vibration stimulus duration was 20 ms, and the interstimulus interval (ISI) was 1000 ms. During the recording, participants placed their hand and forearm on a table with the palm facing upward and relaxed. SEP recordings were conducted at Baseline, Post-NoVTS, and Post-VTS.

Measurement

Proprioceptive outcome measures

Two psychophysical measures of the position sense acuity were obtained from the psychometric response function of each participant. First, the point of subjective equality (PSE) was derived as the border angle corresponding to the 50% “perceived as left” response rate (Fig. 1C). Then the signed angular difference between the perceived and the actual finger position was calculated (ΔPSE = PSE − 50°), representing the systematic error or bias of the perceptual judgment. As individuals could either underestimate or overestimate their finger positions, ΔPSE could be negative or positive. The primary behavioral outcome measure was the absolute value of the variable (|ΔPSE|) representing bias magnitude.

Second, the uncertainty area (UA) was obtained from a psychometric function fitted to individual response data of each participant (Fig. 1C). UA represents the angular difference between the 25% and the 75% thresholds of the psychometric function, measuring the random error or precision of the perceptual judgment (Fig. 1C) reflecting the consistency of the perceiver’s response to repeated presentation of the same stimuli.

SEP outcome measures

Using a zero-phase Finite Impulse Response filter, EEG signals were band-pass filtered (1–40 Hz) with the lower cut-off frequency of 1 Hz selected to address possible slow drift. Each channel was re-referenced to the common average of all electrodes. Each recording was segmented to 500 ms data epochs (− 250 ms to + 250 ms relative to VTS onset). Each epoch was baseline corrected by subtracting the mean voltage of the 250 ms pre-stimulus interval from all samples within that epoch. Epochs were then processed with the Independent Component Analysis using the picard algorithm (Ablin et al. 2018) to filter out potential artifacts from the signals. To remove muscle artifacts arising from gulping or eyeblinks, an automated procedure, ICLabel (Pion-Tonachini et al. 2019), was implemented to identify the independent components not categorized as brain signals. Following preprocessing, approximately 100 artifact-free trials were averaged to obtain the ERP waveform for each participant and condition. P100 amplitude and latency were extracted as EEG outcome measures. The P100 component was quantified at electrode CP3 (or CP4 for left-handed participants), consistent with previous studies demonstrating maximal somatosensory responses over contralateral centro-parietal scalp regions (Fuehrer et al. 2025; Hogendoorn et al. 2015). P100 amplitude was defined as the voltage of the maximum positive peak occurring within an 80–110 ms post-stimulus window, and P100 latency was defined as the time from stimulus onset to that peak.

Statistical analysis

The effect of VTS on the finger position sense bias magnitude was analyzed using a linear mixed-effects model fitted on |ΔPSE| of participants with fixed effects for Condition (No VTS vs. VTS), Site (Fingertip vs. Lateral side of the index finger), and their interaction. To account for repeated-measures structure, a random intercept for participant was included. The effect on the sense’s precision magnitude was examined using a model with the same structure fitted on UA values.

The effects of VTS on P100 amplitude and latency were analyzed using linear mixed-effects models with Time (Baseline, Post-NoVTS, Post-VTS), Site (Fingertip, Lateral), and their interaction as fixed effects. A random intercept for participant was included. The normality of model residuals and random effects was assessed using the Shapiro-Wilk test. Models were fitted using available observations, and observations with missing outcome values were omitted without imputation.

We also performed a post hoc Spearman correlation analysis to examine associations between changes in finger position sense bias magnitude and changes in P100 amplitude across individuals within each stimulation-site group. The 95% confidence intervals were calculated using paired bootstrap resampling with 10,000 resamples and the bias-corrected and accelerated (BCa) method (DiCiccio and Efron 1996).

All analyses were performedAll analyses were performed using R statistical software (version 4.5.2) (R Core Team 2025). Models were first evaluated using omnibus Type III ANOVA tests with Satterthwaite’s approximation for degrees of freedom using the lmerTest package (Kuznetsova et al. 2017). Effect sizes for omnibus ANOVA tests were reported as partial eta-squared (Inline graphic). To test a priori hypotheses regarding VTS effects at each stimulation site, planned contrasts of estimated marginal means were performed using the emmeans package (Lenth and Piaskowski 2026). Additional interaction contrasts were conducted to determine whether VTS-induced changes differed between stimulation sites. Because these contrasts were specified a priori, p-values were reported without adjustment for multiple comparisons.

Results

A site-dependent effect of VTS on finger position sense bias magnitude but not precision

Group means of |ΔPSE| exhibited site-dependent changes across VTS conditions, with the mean increasing with the fingertip stimulation and decreasing with the lateral stimulation (Fig. 2A). The omnibus analysis on the linear mixed-effects model revealed a significant interaction between VTS Condition and Site (F(1, 31) = 5.214, p = 0.029, Inline graphic = 0.14). Neither main effect was significant (Condition: F(1, 31) = 0.252, p = 0.619, Inline graphic = 0.01; Site: F(1, 31) = 0.009, p = 0.927, Inline graphic < 0.001). Planned contrasts (VTS minus NoVTS) indicated a non-significant increase in |ΔPSE| with fingertip stimulation (estimated marginal mean difference = 2.2°, SE = 1.10°, 95% CI = [− 0.04°, 4.44°], p = 0.054), and a non-significant decrease with lateral stimulation (estimated marginal mean difference = − 1.41°, SE = 1.13°, 95% CI = [− 3.72°, 0.90°], p = 0.224). Although neither within-site contrast reached conventional significance, the significant interaction reflects opposite directional changes in |ΔPSE| depending on stimulation site. Individual signed position errors without and with VTS are presented in Fig. 6 to illustrate changes in error magnitude and crossings of the true finger position.

Fig. 2.

Mean absolute position-sense bias increased from about 4.4 to 6.6 degrees with fingertip stimulation, but decreased from about 6.1 to 4.7 degrees with lateral stimulation. The reported interaction p value is 0.029. Mean uncertainty decreased slightly at both sites, with no clear site-specific pattern. Individual trajectories varied in both directions for both measures. Error bars represent one standard error of the mean.

Finger position sense bias magnitude and precision at two assessments. A Group mean |ΔPSE| across VTS conditions for fingertip and lateral stimulation sites; error bars indicate ±1 SEM. A crossover pattern is observed from No VTS to VTS condition with |ΔPSE| increasing following fingertip stimulation and decreasing following lateral stimulation. B and C. Individual |ΔPSE | trajectories from baseline (No VTS) to stimulation (VTS) shown separately for fingertip (B) and lateral (C) stimulation sites. D. Group mean UA across VTS conditions for fingertip and lateral stimulation sites; error bars indicate ±1 SEM. No site-specific trend is observed from No VTS to VTS. E and F. Individual UA trajectories from baseline to stimulation shown separately for fingertip (E) and lateral (F) stimulation sites

Fig. 6.

Signed bias with and without stimulation generally varies in the same direction for both fingertip and lateral groups, though several participants have opposite signs. Points fall on both sides of the equal-bias line. One fingertip participant has a bias near zero without stimulation and about minus 17 degrees with stimulation.

Signed finger position sense Bias (ΔPSE) estimated at assessments without (NoVTS) and with vibrotactile stimulation (VTS). Each point represents one participant in the fingertip or lateral stimulation group. Signed Bias was calculated as ΔPSE = PSE − 50°. The dashed diagonal indicates equal signed error across assessments, and horizontal and vertical zero-reference lines indicate the true finger position (50° relative to horizontal). Opposite signs across assessments indicate that perceived position crossed the true position

In contrast, group means of UA did not differ systematically as a function of stimulation Site or Condition (Fig. 2D). The omnibus analysis revealed neither a significant interaction (F(1, 31) = 0.559, p = 0.46, Inline graphic = 0.02) nor significant main effects (Condition: F(1, 31) = 1.694, p = 0.203, Inline graphic = 0.05; Site: F(1, 31) = 0.063, p = 0.803, Inline graphic = 0.002). Planned contrasts yielded consistent results, with estimated marginal mean differences being negative and non-significant for both stimulation sites. The fingertip stimulation group’s estimated marginal mean difference (VTS minus NoVTS) was − 0.31° (SE = 0.79°, 95% CI = [− 1.91, 1.29]°, p = 0.692), and the lateral stimulation group’s mean difference was − 1.16° (SE = 0.81°, 95% CI = [− 2.81, 0.50]°, p = 0.159). The relevant group means and standard error values are shown in Table 1.

Table 1.

Group means and standard errors (SEM) of |ΔPSE| and UA by VTS Site at two conditions

Fingertip Lateral
No VTS VTS No VTS VTS
|ΔPSE| mean (SEM) 4.40° (0.77°) 6.59° (1.35°) 6.07° (1.19°) 4.67° (1.05°)
UA mean (SEM) 4.23° (0.46°) 3.91° (0.55°) 4.80° (0.80°) 3.64° (0.51°)

Site-dependent changes in contralateral P100 amplitude but not latency

The group-average SEP waveforms exhibited a noticeable divergence in the P100 amplitude following task-associated vibrotactile stimulation depending on the application site. For both finger stimulation sites, P100 amplitude and latency showed similar amplitudes and latencies between the Baseline and the Post-NoVTS recordings. However, at the lateral site, the P100 mean amplitude increased following the intervention (Fig. 3A), while P100 amplitude was lower at Post-VTS than at Post-NoVTS in the fingertip VTS group (Fig. 3B). This visual pattern was also reflected in the group mean P100 amplitudes (Fig. 4A) where both groups remained relatively stable during the baseline phase before showing opposite trends following VTS (Table 2).

Fig. 3.

For lateral stimulation, the P100 response is larger after VTS than at baseline or after no VTS. For fingertip stimulation, P100 amplitudes are similar across the three recordings. The graphs plot mean amplitude against time since stimulus, with vibration lasting from zero to 20 milliseconds.

Site-specific modulation of somatosensory evoked potentials (SEPs). SEP waveforms averaged across participants of each group are shown for the lateral stimulation (A) and the fingertip stimulation (B). The green hatched bar indicates the 20ms vibration period. A P100 showed a higher amplitude in the Post-VTS recording (blue line) compared to the Baseline (grey line) or Post-NoVTS (orange line) recordings. B P100 amplitude remained relatively stable across time points for the fingertip stimulation

Fig. 4.

Mean P100 amplitude crosses over between Post-NoVTS and Post-VTS: it decreases for fingertip stimulation and increases for lateral stimulation. The planned contrast has a p value of 0.041. Mean P100 latency shows no comparable site-specific pattern. Individual amplitude and latency trajectories vary across baseline, Post-NoVTS, and Post-VTS. Group mean error bars represent plus or minus one standard error.

P100 amplitude and latency across SEP recording time points. A Group mean P100 amplitude across SEP recording timepoints for fingertip and lateral stimulation groups; error bars indicate ±1 SEM. A crossover pattern is observed from post-NoVTS to Post-VTS, with P100 amplitude decreasing following fingertip stimulation and increasing following lateral stimulation. B and C. Individual P100 amplitude trajectories across SEP recording timepoints shown separately for fingertip (B) and lateral (C) stimulation sites. D Group mean P100 latency across SEP recording timepoints for fingertip and lateral stimulation sites; error bars indicate ±1 SEM. No site-specific trend is observed from Post-NoVTS to Post-VTS. E and F. Individual P100 latency trajectories across SEP recording times shown separately for fingertip (E) and lateral (F) stimulation sites. X-axis tick labels: B: Baseline, N: Post-NoVTS, V:Post-VTS

Table 2.

Group means and standard errors (SEM) of contralateral P100 amplitude and latency at electrodes CP3/4 by VTS site at the three recording times

Fingertip Lateral 1
Baseline Post-NoVTS Post-VTS Baseline Post-NoVTS Post-VTS

P100 Amplitude (µV)

(SEM)

0.818 (0.182) 0.819 (0.181) 0.663 (0.171) 0.614 (0.182) 0.633 (0.117) 0.879 (0.194)

P100 Latency (ms)

(SEM)

93.7 (2.7) 95.1 (2.9) 94.3 (2.4) 95.9 (2.2) 97.1 (2.7) 94.4 (2.5)

1.Lateral-group P100 amplitude and latency summaries were based on 16 participants at Baseline and 15 participants at each subsequent recording. One participant at Post-NoVTS and a different participant at Post-VTS had no identifiable P100 peak, and the corresponding measures were treated as missing

The omnibus analysis on the fitted model including all three SEP recording timepoints did not identify a statistically significant interaction between Time and Site (F(2, 56.46) = 3.03, p = 0.056, Inline graphic = 0.1). Neither main effect was significant (Time: F(2, 56.46) = 0.202, p = 0.818, Inline graphic = 0.007; Site: F(1, 29.2) = 0.076, p = 0.785, Inline graphic = 0.003). To further assess whether (1) the behavioral task alone modulated P100 amplitude (Post-NoVTS minus Baseline) and (2) VTS would produce a site-specific modulation (Post-VTS minus Post-NoVTS), we conducted planned contrasts using estimated marginal means. No statistically significant differences in P100 amplitude were detected between Baseline and Post-NoVTS at either stimulation site. The fingertip stimulation group’s estimated marginal mean difference was 0.001 µV (SE = 0.139 µV, 95% CI = [− 0.28, 0.28] µV, p = 0.992), and the lateral stimulation group’s mean difference was 0.013 µV (SE = 0.138 µV, 95% CI = [− 0.26, 0.29] µV, p = 0.928).

The planned interaction contrasts specifically tested whether the changes in P100 amplitude from Post-NoVTS to Post-VTS differed between stimulation sites (Fingertip minus Lateral). This difference in changes was statistically significant (estimated difference in changes = − 0.414 µV, SE = 0.198 µV, 95% CI = [− 0.81, − 0.02] µV, p = 0.041). Within-site estimates indicated a non-significant increase in P100 amplitude following lateral stimulation (estimated marginal mean difference = 0.257 µV, SE = 0.141 µV, 95% CI = [− 0.02 µV, 0.54 µV], p = 0.073), and a non-significant decrease following fingertip stimulation (estimated marginal mean difference = − 0.157 µV, SE = 0.139 µV, 95% CI = [− 0.43, 0.12] µV, p = 0.264).

The same evaluation process was applied to the linear mixed-effects model fitted to P100 latency. Neither the main effects of Time or Site nor their interaction reached significance (Time x Site: F(2, 57.18) = 0.12, p = 0.889, Inline graphic = 0.004; Time: F(2, 57.19) = 0.32, p = 0.73, Inline graphic = 0.01; Site: F(1, 29.3) = 0.36, p = 0.551, Inline graphic = 0.01). Planned contrasts comparing adjacent timepoints revealed no statistically significant changes in P100 latency following stimulation of either site. The fingertip stimulation group’s estimated marginal mean difference was 1.33 ms (SE = 3.27 ms, 95% CI = [− 5.22, 7.88] ms, p = 0.685) from Baseline to Post-NoVTS and − 0.8 ms (SE = 3.27 ms, 95% CI = [− 7.35, 5.75] ms, p = 0.808) from Post-NoVTS to Post-VTS. The lateral stimulation group’s estimated marginal mean difference was 1.32 ms (SE = 3.23 ms, 95% CI = [− 5.15, 7.79] ms, p = 0.684) from Baseline to Post-NoVTS and − 2.74 ms (SE = 3.29 ms, 95% CI = [− 9.33, 3.85] ms, p = 0.409) from Post-NoVTS to Post-VTS. The change in P100 latency from Post-NoVTS to Post-VTS did not differ significantly between stimulation-site groups (fingertip minus lateral: estimated difference in changes = 1.94 ms, SE = 4.64 ms, 95% CI = [− 7.35, 11.23] ms, p = 0.678).

No clear association between changes in P100 amplitude and finger position sense bias magnitude

To examine whether VTS-induced changes in finger position sense were associated with changes in somatosensory cortical responses, we plotted the individual change in |ΔPSE| (NoVTS to VTS) against the corresponding change in P100 amplitude (Post-NoVTS to Post-VTS) separately for each stimulation site (Fig. 5).

Fig. 5.

Neither group shows a clear relationship between changes in finger position sense bias magnitude and P100 amplitude. In the fingertip group, bias changes range from about minus 4 to 17 degrees and amplitude changes from about minus 1.4 to 0.7 microvolts. In the lateral group, bias changes range from about minus 9 to 2.5 degrees and amplitude changes from about minus 0.5 to 1.9 microvolts.

Relationship between changes in finger position sense bias magnitude and P100 amplitude following vibrotactile stimulation. The change in P100 amplitude from post-NoVTS to Post-VTS is plotted against the change in the magnitude of finger position sense bias (|ΔPSE|) from NoVTS to VTS. A Individual participant data from the fingertip VTS group. B Individual participant data from the lateral VTS group

Visual inspection revealed substantial inter-individual variability and no clear linear association between behavioral and electrophysiological changes in either stimulation group. Participants who demonstrated large reductions in |ΔPSE| (values at the area left to the vertical dashed lines in Fig. 5A and B) did not consistently exhibit larger increases in P100 amplitude, and vice versa. Spearman correlation analyses were consistent with these observations (Fingertip VTS: ρ = 0.146, 95% CI = [− 0.42, 0.63], p = 0.603; Lateral VTS: ρ = − 0.029, 95% CI = [− 0.64, 0.61], p = 0.923) indicating that VTS-related changes in finger position sense bias were not tightly coupled to changes in P100 amplitude at the individual level.

Discussion

This study examined whether VTS applied during the assessment of finger position sense would alter its acuity and whether the effect of VTS on acuity was dependent on the location of VTS. In addition, we examined the associated electrocortical response before and after experiencing VTS during the finger position sense assessment. The main results can be summarized as follows: First, VTS applied to the index fingertip was associated with an increase in the magnitude of the finger position sense bias (i.e., the distance from the true position), while VTS to the lateral side of the finger was associated with a reduction in bias. Second, no significant site-dependent change in finger position sense precision (i.e., the variability of repeated responses to the same stimuli) was detected. Third, group mean SEP P100 amplitude over contralateral somatosensory cortex changed as a function of VTS location during the position sense assessment. The P100 amplitude was increased after lateral finger VTS while it decreased after VTS was applied to the fingertip. P100 latency did not show any significant VTS location-associated change.

Site-dependent changes in the magnitude of finger position sense bias

One possible explanation for the increased |ΔPSE| observed following fingertip VTS is that the stimulation interfered with sensory information used to estimate finger position. Refshauge et al. (2003) reported that electrical stimulation of the index fingertip, or tactile stimulation of an adjacent finger, impaired the detection of passive movements at the proximal interphalangeal joint of the index finger. Similarly, VTS at 300 Hz applied to the tip of the middle finger demonstrated a similar outcome, suggesting that if stimulation beyond a certain threshold is applied on or near the tested limb, it constitutes noise (Weerakkody et al. 2007). Although the stimulation parameters used in the present study differed from those employed in the previous investigation (30 Hz), repeated VTS applied near the region being evaluated may have altered the sensory information available for finger position judgments.

Nevertheless, the observed effects were not uniform across participants. Eight of the sixteen participants in the fingertip VTS group demonstrated reduced |ΔPSE| following VTS, whereas nine of the seventeen participants in the lateral VTS group exhibited increased |ΔPSE|. These findings suggest substantial inter-individual variability in the response to VTS. Differences in tactile sensitivity, sensory experience, or other individual characteristics may contribute to this variability (Ciano and Beatty 2022; Cohen et al. 2011). The significant interaction between VTS Condition and stimulation Site suggests that the effects of VTS on finger position sense were location-dependent. If fingertip VTS acted as sensory noise that interferes with proprioceptive judgments, the present findings suggest that such interference may be strongest when stimulation is delivered directly to the region being evaluated. Nonetheless, this warrants a caveat because the within-site changes were not statistically significant and individual responses varied substantially (see Fig. 4).

The increased magnitude of finger position sense bias observed in the fingertip VTS group appears inconsistent with previous reports showing improved performance in VTS-assisted reaching tasks (Mikula et al. 2018). However, as Ingram et al. (2019) noted, the accuracy of complex multi-joint movement such as reaching depends not only on proprioceptive information from the moving limb but also on feedforward control processes that generate motor commands based on the positions of both the target and reaching limbs (Kawato 1999; Wolpert et al. 1995). Therefore, reduced reaching error following VTS cannot be interpreted as direct evidence of improved position sense acuity. Repeated exposure to a target location may also allow motor commands to be refined across trials, contributing to improved reaching performance independently of changes in proprioceptive perception.

Site-specific modulation of P100 amplitude following vibrotactile stimulation

The planned interaction contrasts identified a significant site-specific modulation of contralateral P100 amplitude recorded at CP3/CP4. P100 amplitude increased following lateral finger VTS, whereas the opposite trend was observed following fingertip VTS. The mechanisms underlying the reduction in P100 amplitude following fingertip stimulation remain unclear. Simple habituation of cutaneous receptors is unlikely to fully account for this finding, as the vibrotactile stimulation used during the finger position sense assessment (30 Hz, 1000 ms) differed substantially from that used for SEP recording (300 Hz, 20 ms). These differences in stimulation parameters suggest that the two procedures may have engaged partially distinct patterns of somatosensory processing.

The site-specific changes in P100 amplitude may reflect alterations in higher-order somatosensory processing. Previous studies have suggested that the P100 component of SEP originates from the secondary somatosensory cortex (SII) and posterior parietal cortex, regions implicated in the integration of tactile and proprioceptive information (Barba et al. 2004; Forss et al. 1994; Kany and Treede 1997). Both SII and posterior parietal regions have been proposed as sites of multisensory integration in macaque monkeys and humans, particularly for tactile and proprioceptive inputs (Bolognini and Maravita 2007; Fitzgerald et al. 2004; Hsiao 2008; Limanowski and Blankenburg 2016). Tactile and proprioceptive signals project to distinct regions within the primary somatosensory cortex (SI), but anatomical and functional connections between SI and SII suggest that these sensory modalities may be integrated at higher cortical levels. Within this framework, the observed increase in P100 amplitude following lateral VTS may reflect transient changes in somatosensory processing or sensory integration. Larger evoked potentials may arise from greater temporal synchrony and/or contributions from a larger neuronal population (Baratham et al. 2022; Lindén et al. 2011). Such mechanisms could account for the observed amplitude pattern. Whether the site-specific P100 amplitude changes relate to changes in finger position sense or reflect broader changes in somatosensory processing remains unresolved. While the correlation estimates were not significant, confidence intervals encompassing both positive and negative associations prevent a firm conclusion about the absence of the relationship between behavioral and cortical changes.

Limitations

Several aspects of the study design should be considered when interpreting these findings. First, finger position sense was assessed at a single reference position of 50° relative to horizontal. The findings therefore characterize responses at this tested position. Second, during the No-VTS assessment the actuator was absent. Therefore, one cannot differentiate the influence of the tactile stimulation due to actuator contact from the VTS-induced effect, although it is unlikely that just touching the fingers at the two stimulation conditions would have induced such a change in perceptual bias. Third, participants confirmed that vibration was perceptible. However, the perceived intensity of VTS was not quantified and vibration force at the skin-actuator interface was not measured. Differences in receptor density, tissue mechanics, and actuator contact geometry may have resulted in different effective sensory inputs at the two stimulation sites. Although participants did not report that VTS intensity felt different between sites, we cannot fully exclude that differences in VTS intensity contributed to the differences in position sense acuity. Finally, the No-VTS assessment always preceded the assessment with VTS. This order avoided potential carry-over from VTS into the No-VTS assessment but prevented separation of stimulation effects from assessment-order effects. Participants received no explicit feedback about judgment accuracy, and a 20-minute break separated the two assessments. These procedures were intended to reduce feedback-driven learning and fatigue, although task familiarization and other time-dependent effects cannot be excluded.

Conclusion

We investigated the effects of site-specific VTS on finger position sense and somatosensory evoked potentials. Changes in finger position sense bias magnitude differed between stimulation sites with an increase with fingertip VTS and a decrease with lateral VTS. VTS did not significantly influence the precision of finger position judgments. These findings indicate that the location of vibrotactile stimulation can influence the accuracy of finger position sense.

At the cortical level, changes in contralateral P100 amplitude over somatosensory cortex were also site-specific. It increased after lateral VTS but decreased after fingertip VTS. However, changes in P100 amplitude were not significantly correlated with changes in finger position sense bias. Whether the P100 changes relate to position-sense judgments or reflect broader changes in somatosensory processing remains unresolved.

Acknowledgements

We would like to explicitly acknowledge the contribution and insights of coauthor Dr. Hannah Block who unexpectedly passed away in April 2026. This project stems from an ongoing collaboration between Dr. Block’s laboratory at Indiana University and Dr. Konczak’s laboratory at the University of Minnesota.

Appendix

See Fig. 6.

Author contributions

Study conception and design: JO, JK, JX, AM, HB. Material preparation, data collection: JO, JX, AM. Data analysis: JO, JK, JX, AM. Writing of manuscript and data visualization: JO. Reviewing of manuscript: JK, JX, AM.

Funding

This study was supported by a Provost Enhancement Fellowship to JO and research funds from JK.

Data availability

The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.

Declarations

Conflict of interest

The authors declare no competing interests.

Ethics approval and consent to participate

All participants gave written informed consent in accordance with the Declaration of Helsinki. The study was approved by the Institutional Review Board of the University of Minnesota (STUDY00012576).

Consent for publication

All authors or their surviving relative consent to the publication of the manuscript.

Footnotes

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Deceased: Hannah J. Block.

References

  1. Ablin P, Cardoso J-F, Gramfort A (2018) Faster independent component analysis by preconditioning with Hessian approximations. IEEE Trans Signal Process 66(15):4040–4049. 10.1109/TSP.2018.2844203 [DOI] [Google Scholar]
  2. Arnfred SM (2005) Proprioceptive event related potentials: gating and task effects. Clin Neurophysiol: Off J Int Federation Clin Neurophysiol 116(4):849–860. 10.1016/j.clinph.2004.11.010 [DOI] [PubMed] [Google Scholar]
  3. Baratham VL, Dougherty ME, Hermiz J, Ledochowitsch P, Maharbiz MM, Bouchard KE (2022) Columnar localization and laminar origin of cortical surface electrical potentials. J Neurosci 42(18):3733–3748. 10.1523/JNEUROSCI.1787-21.2022 [DOI] [PMC free article] [PubMed] [Google Scholar]
  4. Barba C, Valeriani M, Colicchio G, Tonali P, Restuccia D (2004) Parietal generators of low- and high-frequency MN (median nerve) SEPs: Data from intracortical human recordings. Clin Neurophysiol 115(3):647–657. 10.1016/j.clinph.2003.10.024 [DOI] [PubMed] [Google Scholar]
  5. Bolanowski SJ, Zwislocki JJ (1984) Intensity and frequency characteristics of pacinian corpuscles. II. Receptor potentials. J Neurophysiol 51(4):812–830. 10.1152/jn.1984.51.4.812 [DOI] [PubMed] [Google Scholar]
  6. Bolognini N, Maravita A (2007) Proprioceptive alignment of visual and somatosensory maps in the posterior parietal cortex. Curr Biol 17(21):1890–1895. 10.1016/j.cub.2007.09.057 [DOI] [PubMed] [Google Scholar]
  7. Burton H, Fabri M (1995) Ipsilateral intracortical connections of physiologically defined cutaneous representations in areas 3b and 1 of macaque monkeys: projections in the vicinity of the central sulcus. J Comp Neurol 355(4):508–538. 10.1002/cne.903550404 [DOI] [PubMed] [Google Scholar]
  8. Ciano J, Beatty BL (2022) Regional variation in the density of Meissner’s corpuscles in human fingers. Ann Anat - Anatomischer Anzeiger 243:151946. 10.1016/j.aanat.2022.151946 [DOI] [PubMed] [Google Scholar]
  9. Clark FJ, Horch KW, Bach SM, Larson GF (1979) Contributions of cutaneous and joint receptors to static knee-position sense in man. J Neurophysiol 42(3):877–888. 10.1152/jn.1979.42.3.877 [DOI] [PubMed] [Google Scholar]
  10. Cohen H, Scherzer P, Viau R, Voss P, Lepore F (2011) Working memory for Braille is shaped by experience. Commun Integr Biol 4(2):227–229. 10.4161/cib.4.2.14546 [DOI] [PMC free article] [PubMed] [Google Scholar]
  11. Delhaye BP, Long KH, Bensmaia SJ (2018) Neural basis of touch and proprioception in primate cortex. Compr Physiol 8(4):1575–1602. 10.1002/cphy.c170033 [DOI] [PMC free article] [PubMed] [Google Scholar]
  12. Desmedt JE, Robertson D (1977) Differential enhancement of early and late components of the cerebral somatosensory evoked potentials during forced-paced cognitive tasks in man. J Physiol 271(3):761–782. 10.1113/jphysiol.1977.sp012025 [DOI] [PMC free article] [PubMed] [Google Scholar]
  13. DiCiccio TJ, Efron B (1996) Bootstrap confidence intervals. Stat Sci 11(3):189–228. 10.1214/ss/1032280214 [DOI] [Google Scholar]
  14. Eimer M, Forster B (2003) Modulations of early somatosensory ERP components by transient and sustained spatial attention. Exp Brain Res 151(1):24–31. 10.1007/s00221-003-1437-1 [DOI] [PubMed] [Google Scholar]
  15. Fitzgerald PJ, Lane JW, Thakur PH, Hsiao SS (2004) Receptive field properties of the macaque second somatosensory cortex: evidence for multiple functional representations. J Neurosci 24(49):11193–11204. 10.1523/JNEUROSCI.3481-04.2004 [DOI] [PMC free article] [PubMed] [Google Scholar]
  16. Forss N, Hari R, Salmelin R, Ahonen A, Hamalainen M, Kajola M, Knuutila J, Simola J (1994) Activation of the human posterior parietal cortex by median nerve stimulation. Exp Brain Res 99(2). 10.1007/BF00239597 [DOI] [PubMed]
  17. Fuehrer E, Maurer LK, Fiehler K (2025) Characterizing SEPs from Pacinian-targeted vibrations. J Neurophysiol 134(4):1185–1196. 10.1152/jn.00304.2025 [DOI] [PubMed] [Google Scholar]
  18. Hogendoorn H, Kammers M, Haggard P, Verstraten F (2015) Self-touch modulates the somatosensory evoked P100. Exp Brain Res 233(10):2845–2858. 10.1007/s00221-015-4355-0 [DOI] [PMC free article] [PubMed] [Google Scholar]
  19. Hsiao S (2008) Central mechanisms of tactile shape perception. Curr Opin Neurobiol 18(4):418–424. 10.1016/j.conb.2008.09.001 [DOI] [PubMed] [Google Scholar]
  20. Ingram LA, Butler AA, Gandevia SC, Walsh LD (2019) Proprioceptive measurements of perceived hand position using pointing and verbal localisation tasks. PLoS ONE 14(1):e0210911. 10.1371/journal.pone.0210911 [DOI] [PMC free article] [PubMed] [Google Scholar]
  21. Kany C, Treede R-D (1997) Median and tibial nerve somatosensory evoked potentials: middle-latency components from the vicinity of the secondary somatosensory cortex in humans.Electroencephalogr Clin Neurophysiol/Evoked Potentials Sect  104(5):402–410. 10.1016/S0168-5597(97)00045-2 [DOI] [PubMed] [Google Scholar]
  22. Kawato M (1999) Internal models for motor control and trajectory planning. Curr Opin Neurobiol 9(6):718–727. 10.1016/S0959-4388(99)00028-8 [DOI] [PubMed] [Google Scholar]
  23. Kida T, Wasaka T, Nakata H, Akatsuka K, Kakigi R (2006) Active attention modulates passive attention-related neural responses to sudden somatosensory input against a silent background. Exp Brain Res 175(4):609–617. 10.1007/s00221-006-0578-4 [DOI] [PubMed] [Google Scholar]
  24. Kim SS, Gomez-Ramirez M, Thakur PH, Hsiao SS (2015) Multimodal interactions between proprioceptive and cutaneous signals in primary somatosensory cortex. Neuron 86(2):555–566. 10.1016/j.neuron.2015.03.020 [DOI] [PMC free article] [PubMed] [Google Scholar]
  25. Krubitzer LA, Kaas JH (1990) The organization and connections of somatosensory cortex in marmosets. J Neurosci: Off J Soc Neurosci 10(3):952–974. 10.1523/JNEUROSCI.10-03-00952.1990 [DOI] [PMC free article] [PubMed] [Google Scholar]
  26. Kuznetsova A, Brockhoff PB, Christensen RHB (2017) lmerTest package: tests in linear mixed effects models. J Stat Softw 82(13). 10.18637/jss.v082.i13 [DOI]
  27. Lenth RV, Piaskowski J (2026) emmeans: Estimated Marginal Means, aka Least-Squares Means[Computer software]. https://CRAN.R-project.org/package=emmeans
  28. Limanowski J, Blankenburg F (2016) Integration of Visual and Proprioceptive Limb Position Information in Human Posterior Parietal, Premotor, and Extrastriate Cortex. J Neurosci 36(9):2582–2589. 10.1523/JNEUROSCI.3987-15.2016 [DOI] [PMC free article] [PubMed] [Google Scholar]
  29. Lindén H, Tetzlaff T, Potjans TC, Pettersen KH, Grün S, Diesmann M, Einevoll GT (2011) Modeling the spatial reach of the LFP. Neuron 72(5):859–872. 10.1016/j.neuron.2011.11.006 [DOI] [PubMed] [Google Scholar]
  30. Mikula L, Sahnoun S, Pisella L, Blohm G, Khan AZ (2018) Vibrotactile information improves proprioceptive reaching target localization. PLoS ONE 13(7):e0199627. 10.1371/journal.pone.0199627 [DOI] [PMC free article] [PubMed] [Google Scholar]
  31. Mildren RL, Hare CM, Bent LR (2017) Cutaneous afferent feedback from the posterior ankle contributes to proprioception. Neurosci Lett 636:145–150. 10.1016/j.neulet.2016.10.058 [DOI] [PubMed] [Google Scholar]
  32. Moberg E (1983) The role of cutaneous afferents in position sense, kinaesthesia, and motor function of the hand. Brain 106(1):1–19. 10.1093/brain/106.1.1 [DOI] [PubMed] [Google Scholar]
  33. Oh J, Mahnan A, Xu J, Holst-Wolf J, Block H, Konczak J (2020) A system for the objective assessment of hand proprioceptive function in pediatric and adult populations. DMD2020. 10.1115/DMD2020-9088 [DOI]
  34. Oh J, Mahnan A, Xu J, Block HJ, Konczak J (2023) Typical development of finger position sense from late childhood to adolescence. J Mot Behav 55(1):102–110. 10.1080/00222895.2022.2134287 [DOI] [PubMed] [Google Scholar]
  35. Ohye C, Narabayashi H (1979) Physiological study of presumed ventralis intermedius neurons in the human thalamus. J Neurosurg 50(3):290–297. 10.3171/jns.1979.50.3.0290 [DOI] [PubMed] [Google Scholar]
  36. Oldfield RC (1971) The assessment and analysis of handedness: the Edinburgh inventory. Neuropsychologia 9(1):97–113. 10.1016/0028-3932(71)90067-4 [DOI] [PubMed] [Google Scholar]
  37. Pion-Tonachini L, Kreutz-Delgado K, Makeig S (2019) ICLabel: an automated electroencephalographic independent component classifier, dataset, and website. NeuroImage 198:181–197. 10.1016/j.neuroimage.2019.05.026 [DOI] [PMC free article] [PubMed] [Google Scholar]
  38. Prins N (2013) The psi-marginal adaptive method: how to give nuisance parameters the attention they deserve (no more, no less). J Vis 13(7):3–3. 10.1167/13.7.3 [DOI] [PubMed] [Google Scholar]
  39. R Core Team (2025) R: a language and environment for statistical computing [Data set]. R Foundation for Statistical Computing
  40. Refshauge KM, Collins DF, Gandevia SC (2003) The detection of human finger movement is not facilitated by input from receptors in adjacent digits. J Physiol 551(1):371–377. 10.1113/jphysiol.2003.045997 [DOI] [PMC free article] [PubMed] [Google Scholar]
  41. Schubert R, Blankenburg F, Lemm S, Villringer A, Curio G (2006) Now you feel it–now you don’t: ERP correlates of somatosensory awareness. Psychophysiology 43(1):31–40. 10.1111/j.1469-8986.2006.00379.x [DOI] [PubMed] [Google Scholar]
  42. Sherrington C (1906) The integrative action of the nervous system. Original work published Yale University
  43. Tanaka E, Inui K, Kida T, Miyazaki T, Takeshima Y, Kakigi R (2008) A transition from unimodal to multimodal activations in four sensory modalities in humans: an electrophysiological study. BMC Neurosci 9:116. 10.1186/1471-2202-9-116 [DOI] [PMC free article] [PubMed] [Google Scholar]
  44. Ulkar B, Kunduracioglu B, Cetin C, Güner RS (2004) Effect of positioning and bracing on passive position sense of shoulder joint. Br J Sports Med 38(5):549–552. 10.1136/bjsm.2002.004275 [DOI] [PMC free article] [PubMed] [Google Scholar]
  45. Vallbo AB, Johansson RS (1984) Properties of cutaneous mechanoreceptors in the human hand related to touch sensation. Hum Neurobiol 3(1):3–14 [PubMed] [Google Scholar]
  46. Weerakkody NS, Mahns DA, Taylor JL, Gandevia SC (2007) Impairment of human proprioception by high-frequency cutaneous vibration. J Physiol 581(3):971–980. 10.1113/jphysiol.2006.126854 [DOI] [PMC free article] [PubMed] [Google Scholar]
  47. Wolpert DM, Ghahramani Z, Jordan MI (1995) An internal model for sensorimotor integration. Science 269(5232):1880–1882. 10.1126/science.7569931 [DOI] [PubMed] [Google Scholar]